A-101 — A 101 Floor Plan

Demo: Dentist / Rev E / architectural / pdf_2d

13 clause(s)

LabelTextPageExtraction method
1 1. All partitions new 3-5/8" metal stud w/ 5/8" GWB ea. side U.N.O. 1 pdf_text
101 101 WAITING /IRECEPTION 1 pdf_text
103 103 RESTROOMI(ACCESSIBLE) 1 pdf_text
104 104 MECH / ELECIROOM 1 pdf_text
110 110 STAFF BREAKIROOM 1 pdf_text
113 113 COL DIM'D @ 47'-6" FROMIGRID 1 (FIELD VERIFY) 1 pdf_text
2 2. Existing building shell & structure by others; verify all dimensions in field prior to fabrication. 1 pdf_text
3 3. See A-102 for life safety / egress plan. 1 pdf_text
4 4. See S-101 for column and structural grid locations. 1 pdf_text
40 40"ICLR DOOR SWINGSIINTO CORRIDOR GENERAL NOTES 1 pdf_text
4400 4400 W. City of Ch Permit No Floor Occupan Drawn: J. REVISION A 06/15/26 N SCALE: 1/8" = 1'-0" (SCHEMATIC, NOT TO SCALE) 1 pdf_text
5 5. Corridor 106 clear width shown 3'-4" (40") -- VERIFY code minimum for occupant load served (see A-102 egress calc). 1 pdf_text
6 6. Column at Grid C/3 dimensioned 47'-6" from Grid 1 per existing field conditions -- coordinate with S-101 which shows column on grid (48'-0"). 1 pdf_text