Plan Review Copilot
← back to flags
Audit trail

Reasoning trace

Clause: 2
Severity: medium
Engine: real / claude-sonnet-5
Tokens: 1655 in / 278 out
Latency: 3795 ms
Called: 2026-08-09 07:01:09

Flag explanation

Structural clause 1 identifies a 6-inch discrepancy between the structural grid location of the column at Grid C/3 (48'-0" from Grid 1) and the architectural floor plan dimension (47'-6" from Grid 1) based on field verification. Architectural clause 2's general instruction to verify all dimensions in the field prior to fabrication does not resolve this specific documented conflict between the architectural and structural drawings; the discrepancy must be explicitly reconciled between the architect and structural engineer before partitions or casework are set, as noted in the structural clause.

Prompt sent to model

Clause '2' (architectural):
2. Existing building shell & structure by others; verify all
   dimensions in field prior to fabrication.

Candidate clauses from other disciplines in the same submission (only these may be cited):
[id: 8134ea51-ab17-4add-9fb1-ab1dcdc9c893] mechanical 5: 5. Verify roof structure capacity with the structural engineer prior to setting any rooftop equipment; see the RTU-1 note above.

[id: 0634ba34-e348-45ef-965c-0b73095bb9fa] civil 8: 8. Existing building setbacks to be field-verified; see the setback note above for required minimums under the current zoning district.

[id: 570c9fd7-f475-47eb-a09d-2874b6c08d9c] structural 8: 8. Existing roof structure to remain except as noted; new point loads from mechanical equipment require verification against the original roof design documents, which are not available for this building -- the 2,000 lb allowance noted above for BM-7 is an assumed allowable
pending that verification.

[id: 7f90f154-e493-43c1-a813-58091925da17] structural 3: 3. Beam BM-4 (Grid B, bay 2-3): W10X22, 24'-0" long, bottom of steel +9'-0" AFF -- note that the framing plan callout for BM-4 elsewhere on this sheet reads W12X26; field-verify and confirm the correct size with this office before fabrication, as the two callouts for the same
mark do not agree.

[id: 947c21fa-7f9c-496f-ac30-271f27246407] structural 1: 1. All new and existing columns are located strictly on the structural grid unless individually dimensioned otherwise. The column at Grid C/3, adjacent to the Sterilization/Storage partition, is located on grid at 48'-0" from Grid 1. The architectural floor plan (A-101)
dimensions this same column at 47'-6" from Grid 1 based on field conditions observed during their site walkthrough. Reconcile this 6" discrepancy with the architect before partitions or casework are set relative to this column.

Does this clause create a coordination conflict with any of the candidates above - i.e. do they describe the same physical space, element, or system in a way that is physically or functionally incompatible? Call report_cross_discipline_conflicts with your findings, or an empty conflicts list if there's no real conflict.

Raw model response

{"conflicts": [{"severity": "medium", "explanation": "Structural clause 1 identifies a 6-inch discrepancy between the structural grid location of the column at Grid C/3 (48'-0\" from Grid 1) and the architectural floor plan dimension (47'-6\" from Grid 1) based on field verification. Architectural clause 2's general instruction to verify all dimensions in the field prior to fabrication does not resolve this specific documented conflict between the architectural and structural drawings; the discrepancy must be explicitly reconciled between the architect and structural engineer before partitions or casework are set, as noted in the structural clause.", "cited_clause_ids": ["947c21fa-7f9c-496f-ac30-271f27246407"]}]}