Hartford, CT — Connecticut State Building Code (2022, incl. 2021 IBC portion)

(jurisdiction reference document) / - / - / state_code_pdf

1319 clause(s)

LabelTextPageExtraction method
0 0 inches (0 mm) to noncombustible material. Exceptions: - pdf_text
0.051 0.051 Type B Type A Yes Stratford - pdf_text
0.052 0.052 Yes Norwalk - pdf_text
0.052 0.052 Type B Type A Yes Guilford - pdf_text
0.053 0.053 Type B Type A Yes - pdf_text
0.053 0.053 Type B Type B Yes Old Saybrook - pdf_text
0.053 0.053 Type B Type B Yes East Lyme - pdf_text
0.053 0.053 Type B Type B Yes Monroe - pdf_text
0.053 0.053 Yes Lisbon - pdf_text
0.053 0.053 Yes Wallingford - pdf_text
0.053 0.053 Yes Prospect - pdf_text
0.053 0.053 Type B Type B Yes Orange - pdf_text
0.053 0.053 Type B Type B Yes Westbrook - pdf_text
0.053 0.053 Type B Type B Yes Bridgeport - pdf_text
0.053 0.053 Type B Type B Yes Watertown - pdf_text
0.053 0.053 Type B Type B Yes East Windsor - pdf_text
0.054 0.054 Yes Berlin - pdf_text
0.054 0.054 North Haven - pdf_text
0.054 0.054 Yes Greenwich - pdf_text
0.054 0.054 Yes Woodstock - pdf_text
0.054 0.054 Beacon Falls - pdf_text
0.054 0.054 Yes Seymour - pdf_text
0.054 0.054 Yes Putnam - pdf_text
0.054 0.054 Yes Branford - pdf_text
0.054 0.054 Yes Southington - pdf_text
0.054 0.054 Yes Waterford - pdf_text
0.054 0.054 Yes North Canaan - pdf_text
0.054 0.054 Yes Bloomfield - pdf_text
0.054 0.054 Type B Type B Yes Manchester - pdf_text
0.054 0.054 Yes West Hartford - pdf_text
0.054 0.054 Yes Morris - pdf_text
0.054 0.054 Yes Brookfield - pdf_text
0.054 0.054 Type B Type B Yes Colchester - pdf_text
0.054 0.054 Yes Madison - pdf_text
0.054 0.054 Yes Somers - pdf_text
0.054 0.054 Yes Sharon - pdf_text
0.054 0.054 Yes North Stonington - pdf_text
0.054 0.054 Yes Burlington - pdf_text
0.054 0.054 Yes Thompson - pdf_text
0.054 0.054 Yes New Britain - pdf_text
0.054 0.054 Yes Stonington - pdf_text
0.054 0.054 Yes Stafford - pdf_text
0.054 0.054 Yes Woodbury - pdf_text
0.054 0.054 Yes Plainfield - pdf_text
0.054 0.054 Yes Pomfret - pdf_text
0.054 0.054 Yes Plainville - pdf_text
0.054 0.054 Yes Ashford - pdf_text
0.054 0.054 Yes Oxford - pdf_text
0.054 0.054 Yes Thomaston - pdf_text
0.054 0.054 Yes Bethel - pdf_text
0.054 0.054 Yes Middlefield - pdf_text
0.054 0.054 Yes Durham - pdf_text
0.054 0.054 Type B Type B Yes Haddam - pdf_text
0.054 0.054 Yes East Haddam - pdf_text
0.054 0.054 Type B Type B Yes Weston - pdf_text
0.054 0.054 Type B Yes Suffield - pdf_text
0.054 0.054 Yes Canaan - pdf_text
0.054 0.054 Yes Old Lyme - pdf_text
0.054 0.054 Yes Litchfield - pdf_text
0.054 0.054 Yes Woodbridge - pdf_text
0.054 0.054 Yes Hartford - pdf_text
0.054 0.054 Type B Type B Yes New London - pdf_text
0.054 0.054 Yes Salem - pdf_text
0.054 0.054 North Branford - pdf_text
0.054 0.054 Yes Chaplin - pdf_text
0.054 0.054 Yes Union - pdf_text
0.054 0.054 Yes Canton - pdf_text
0.054 0.054 Yes Groton - pdf_text
0.054 0.054 Yes Glastonbury - pdf_text
0.054 0.054 Yes Hebron - pdf_text
0.054 0.054 Yes Barkamsted - pdf_text
0.054 0.054 New Haven - pdf_text
0.054 0.054 Type B Yes Bridgewater - pdf_text
0.054 0.054 Yes Fairfield - pdf_text
0.054 0.054 Yes Derby - pdf_text
0.055 0.055 Yes South Windsor - pdf_text
0.055 0.055 Yes Torrington - pdf_text
0.055 0.055 Yes New Canaan - pdf_text
0.055 0.055 Yes Hartland - pdf_text
0.055 0.055 Yes Salisbury - pdf_text
0.055 0.055 Yes Stamford - pdf_text
0.055 0.055 Yes Vernon - pdf_text
0.055 0.055 Yes Cheshire - pdf_text
0.055 0.055 Yes Goshen - pdf_text
0.055 0.055 Yes Willington - pdf_text
0.055 0.055 Yes Chester - pdf_text
0.055 0.055 Yes Redding - pdf_text
0.055 0.055 Yes Killingworth - pdf_text
0.055 0.055 Yes Essex - pdf_text
0.055 0.055 Yes Easton - pdf_text
0.055 0.055 Yes Windsor - pdf_text
0.055 0.055 Yes East Haven - pdf_text
0.055 0.055 Yes Ledyard - pdf_text
0.055 0.055 Yes Enfield - pdf_text
0.055 0.055 Type B Yes Farmington - pdf_text
0.055 0.055 Yes Portland - pdf_text
0.055 0.055 Yes Voluntown - pdf_text
0.055 0.055 Yes Montville - pdf_text
0.055 0.055 Yes Bethany - pdf_text
0.055 0.055 Yes Kent - pdf_text
0.055 0.055 Yes Clinton - pdf_text
0.055 0.055 Yes Roxbury - pdf_text
0.055 0.055 Yes Plymouth - pdf_text
0.055 0.055 Yes Norfolk - pdf_text
0.055 0.055 Yes East Granby - pdf_text
0.055 0.055 Yes Middletown - pdf_text
0.055 0.055 Yes Southbury - pdf_text
0.055 0.055 Yes Eastford - pdf_text
0.055 0.055 Yes Ellington - pdf_text
0.055 0.055 Yes Warren - pdf_text
0.055 0.055 Yes Cromwell - pdf_text
0.055 0.055 Yes Wilton - pdf_text
0.055 0.055 Yes Hamden - pdf_text
0.055 0.055 Yes Bolton - pdf_text
0.055 0.055 Yes Lebanon - pdf_text
0.055 0.055 Yes Mansfield - pdf_text
0.055 0.055 Yes Bozrah - pdf_text
0.055 0.055 Yes Newtown - pdf_text
0.055 0.055 Yes Middlebury - pdf_text
0.055 0.055 Yes Ansonia - pdf_text
0.055 0.055 Yes Windsor Locks - pdf_text
0.055 0.055 Yes West Haven - pdf_text
0.055 0.055 Yes Avon - pdf_text
0.055 0.055 Yes Marlborough - pdf_text
0.055 0.055 Yes Franklin - pdf_text
0.055 0.055 Yes Brooklyn - pdf_text
0.055 0.055 Yes Sprague - pdf_text
0.055 0.055 Yes Colebrook - pdf_text
0.055 0.055 Yes Wolcott - pdf_text
0.056 0.056 New Hartford - pdf_text
0.056 0.056 Yes Milford - pdf_text
0.056 0.056 Yes East Hartford - pdf_text
0.056 0.056 Yes Westport - pdf_text
0.056 0.056 Yes Darien - pdf_text
0.056 0.056 Type B Yes Norwich - pdf_text
0.056 0.056 Type B Yes - pdf_text
0.056 0.056 Yes Meriden - pdf_text
0.056 0.056 Yes Tolland - pdf_text
0.056 0.056 Yes Danbury - pdf_text
0.056 0.056 Yes Ridgefield - pdf_text
0.056 0.056 Yes East Hampton - pdf_text
0.056 0.056 Yes Bethlehem - pdf_text
0.056 0.056 Yes Preston - pdf_text
0.057 0.057 Type B Yes Deep River - pdf_text
0.057 0.057 Yes Winchester - pdf_text
0.057 0.057 Yes Rocky Hill - pdf_text
0.058 0.058 Yes New Fairfield - pdf_text
0.058 0.058 Type B Yes Sterling - pdf_text
0.059 0.059 Type B Yes Griswold - pdf_text
1 1. The following low-energy buildings, or portions thereof, separated from the remainder o building by building thermal envelope assemblies complying with this section shall be exempt the building thermal envelope provisions of Section R402: - pdf_text
1 1. Electrical equipment rooms. - pdf_text
1 1. For occupancies in Group R-3 not more than three stories above grade in height, and w individual dwelling units in occupancies in Group R-2 not more than three stories above gra height with separate means of egress, required guards shall be not less than 36 inches (914 in height measured vertically above the adjacent walking surfaces. - pdf_text
1 1. The stopping of leaks in drains, water, soil, waste or vent pipe; provided if any concealed drainpipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to re and replace the same with new material, such work shall be considered as new work and a p shall be obtained and inspection made as provided in Sections R105 and R109 of this code. - pdf_text
1 1. Where there are no communicating openings between the private garage and the dwelling u sleeping unit. - pdf_text
1 1. Having four stories; - pdf_text
1 1. Buildings protected throughout by an approved automatic sprinkler system in accordance - pdf_text
1 1. The following low energy buildings, or portions thereof, separated from the remainder o building by building thermal envelope assemblies complying with this section shall be ex from the building thermal envelope provisions of Section N1102. - pdf_text
1 1. Dead load (including photovoltaic panel weight) plus snow load in accordance with Table R3 (Add) R324.5.4 Required signage. Where a BIPV system is installed, a placard shall be provided on outside of the building at the electrical service meter location to which the BIPV system is connected. The placard shall display a fire fighter Maltese cross with “PV” printed in the center of the cross. Th placard shall be not less than 4 inches (102 mm) by 6 inches (152 mm) in size and made of an approv durable material. (Amd) R324.6 Roof access and pathways. Roof access, pathways and setback requirements shall be provided in accordance with Sections R324.6.1 through R324.6.2.1. Access and minimum spacing sh be required to provide emergency access to the roof, to provide pathways to specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. Exceptions: - pdf_text
1 1. A fire alarm system is not required in buildings not more than two stories in height wher dwelling units or sleeping units and contiguous attic and crawl spaces are separated from other and public or common areas by at least 1-hour fire partitions and each dwelling un sleeping unit has an exit directly to a public way, egress exit, court or yard. - pdf_text
1 1. Other than storm shelters, one-story detached accessory structures used as tool and storage s playhouses and similar uses, provided the floor area is not greater than 200 square feet (18.58 - pdf_text
1 1. Detached, nonhabitable structures, including, but not limited to, detached garages, parking s structures, carports, solar trellises and similar structures, shall not be required to provide access. - pdf_text
1 1. The number of Type A units is permitted to be reduced in accordance with Section 1108.7. - pdf_text
1 1. Failure of a public utility or other outside electrical power supply. - pdf_text
1 1. Tents used exclusively for recreational camping purposes. - pdf_text
1 1. The width of spiral stairways shall be in accordance with Section R311.7.10.1. - pdf_text
1 1 unit vertical in 12 units horizontal (1:12), or where physical barriers prevent the installation accessible route, a vehicular route with parking that complies with Section 1106 of the International Building Code portion of the 2022 Connecticut State Building Code at each publ common use facility or building is permitted in place of the accessible route. (Add) R320.6 Parking. Two percent, but not less than one, of each type of parking space provid occupancies which are required to have Type B dwelling units shall be accessible. For each six or fra of six accessible parking spaces, at least one shall be a van-accessible parking space. (Add) R320.6.1 Parking within or beneath a building. Where parking is provided within or bene building, accessible parking spaces shall also be provided within or beneath the building. Exception: Private parking garages within or beneath the building that contain no more than parking spaces, that are reserved for the exclusive use of a specific dwelling unit and are dir accessed from that dwelling unit are not required to be accessible. (Add) R320.6.2 Automobile accessible parking spaces. Pursuant to subsection (h) of section 14-25 the Connecticut General Statutes, parking spaces for passenger motor vehicles designated for persons are blind and persons with disabilities shall be as near as possible to a building entrance or walkwa shall be 15 feet (4572 mm) wide, including 5 feet (1524 mm) of cross hatch. - pdf_text
1 1. The following minimum fixtures shall be provided in Group R-1 bed and breakfast establish Water closets – one per two guestrooms; lavatories – one per two guestrooms; bathtubs/sho one per two guestrooms. Plumbing fixtures in Group R-1 bed and breakfast establishments sh permitted to be accessed from hallways and corridors and to be shared by guests. - pdf_text
1 1. Within 1 mile (1.61 km) of the mean high-water line where an Exposure D condition exists up at the waterline and the basic design wind speed, V, is 130 mph (58 m/s) or greater; or - pdf_text
1 1 Batterymarch Park Quincy, MA 02269 UL LLC - pdf_text
1 1. For buildings complying with Section R401.2.1, one of the additional efficiency pac options shall be installed according to Section R408.2. - pdf_text
1 1. The carbon monoxide detectors may be battery operated or plug-in and are not required t interconnected when other remodeling considerations do not require the removal of the approp wall or ceiling coverings to facilitate concealed interconnected wiring. - pdf_text
1 1. Group E occupancies in accordance with Section 915.2.3. - pdf_text
1 1. The stopping of leaks in drains, water, soil, waste or vent pipe; provided, however, that if concealed trap, drain pipe, water, soil, waste or vent pipe becomes defective and it bec necessary to remove and replace the same with new material, such work shall be considered work and a permit shall be obtained and inspection made as provided in this code. - pdf_text
1 1. No additional snow drift loads will be induced on the roof of the adjacent existing building. - pdf_text
1 1. The maximum riser height of existing stairs serving existing unfinished attics or exi unfinished basements being converted to habitable space or replacement stairs where the pit slope cannot be reduced because of existing construction shall be 9 inches (229 mm), measur accordance with Section R311.7.5.1. - pdf_text
1 1 Batterymarch Park Quincy, MA 02269-9101 (Del) APPENDIX A – PLUMBING PERMIT FEE SCHEDULE. Delete appendix. (Del) APPENDIX F – BOARD OF APPEALS. Delete appendix. - pdf_text
1 1. The requirements of the sections indicated within Table 406.2. - pdf_text
1 1 Batterymarch Park Quincy, MA 02269-9101 - pdf_text
1 1. Listed cord-and-plug connected temporary decorative lighting. - pdf_text
1 1. Facilities with smoke-protected assembly seating shall be permitted to use the capacity facto Table 1030.6.2 indicated for stepped aisles for exit access or exit stairways where the entire for means of egress from the seating to the exit discharge is provided with a smoke control sy complying with Section 909. - pdf_text
1 1. From the adjacent walking surfaces. - pdf_text
1 1. Where all spaces normally subject to student occupancy have not less than one door ope directly to the outside or to an exterior or exit access balcony or corridor in accordance with Se - pdf_text
1 1. Grade floor openings or below grade openings shall have a net clear opening of not less th square feet (0.465 m2). - pdf_text
1 1. In existing buildings principally used for meeting, gathering or assembling by any civic, relig fraternal or charitable organization. - pdf_text
1 1. Work for which a certificate of approval is issued in accordance with Section R110.9. - pdf_text
1 1. Work for which a certificate of approval is issued in accordance with Section 111.6. - pdf_text
1 1. Live/work units in one- and two-family dwellings, that provide professional services and emp maximum of one employee within the dwelling in addition to the residents of the dwelling unit, be permitted to comply with the requirements of the 2021 International Residential Code porti the 2022 Connecticut State Building Code. - pdf_text
1 1. Facilities with smoke-protected assembly seating shall be permitted to use the capacity facto Table 1030.6.2 indicated for level or ramped aisles for means of egress components other stairways where the entire path for means of egress from the seating to the exit dischar provided with a smoke control system complying with Section 909. - pdf_text
1 1. The following minimum fixtures shall be provided in Group R-1 bed and breakfast establishments: Water closets – one per two guestrooms; lavatories – one per two guestroom bathtubs/showers – one per two guestrooms. Plumbing fixtures in Group R-1 bed and breakf establishments shall be permitted to be accessed from hallways and corridors and to be share guests. - pdf_text
1 1 in 7. If any sampled units fail compliance with the maximum allowed air leakage rate additional units in the same sample set shall be tested. If additional failures occur, all un the sample set shall be tested. In addition, all units in the next sample set shall be teste compliance before sampling of further units can be continued. This exception is not all for multi-zone buildings that are treated as single-zone buildings by opening interior doo by inducing equal pressures in adjacent zones. Mechanical ventilation shall be provided in accordance with Section M1505.4 of the Internat Residential Code or Section 403.3.2 of the International Mechanical Code, as applicable, or with approved means of ventilation. (Amd) R402.4.1.3 Leakage rate. When complying with Section R401.2.1, the building or dwelling shall have an air leakage rate not exceeding 3.0 air changes per hour, when tested in accordance with Se R402.4.1.2. (Add) R403.3.1.1 Duct insulation values. Minimum duct insulation values stated in Section 403.3.1 be installed R-values. (Amd) R403.6 Mechanical ventilation. The buildings complying with Section R402.4.1 shall be pro with ventilation that complies with the requirements of Section M1505.4 of the International Reside Code or International Mechanical Code, as applicable, or with other approved means of ventila Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventil system is not operating. - pdf_text
1 1. Curved stairways in accordance with Section 1011.9. - pdf_text
1 1. Separation walls as required by Section 420.2 for Group I-1 and Group R occupancies. Exception: Group R-1 bed and breakfast establishments. - pdf_text
1 1. The facility is not in a building containing mixed occupancies, - pdf_text
1 1. Carbon monoxide detection shall not be required in dwelling units and sleeping units wi communicating openings between the fuel-burning appliance or fuel-burning fireplace an dwelling unit or sleeping unit. - pdf_text
1 1. Work involving the exterior surfaces of dwellings, such as the replacement of roofing or sidin the addition or replacement of windows or doors, or the addition of a porch or deck, are ex from the requirements of this section. - pdf_text
1 1. When testing individual dwelling units, an air leakage rate not exceeding 0.30 cubic fee minute per square foot [0.008 m3/(s × m2)] of the dwelling unit enclosure area, test accordance with ANSI/RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported pressure of 0.2 inch w.g. (50 Pa), shall be an accepted alternative permitted in all climate z for: a. Attached dwelling units. b. Dwelling units that are 1,500 ft2 (139.4 m2 ) or smaller. - pdf_text
1 1. Existing and replacement stairways in existing structures shall not be required to comply wit requirements of Section 1011.5 of the International Building Code, where the pitch or slope ca be reduced because of existing construction. - pdf_text
1 1. When the premises have been cleared of all combustible materials and debris and, in the opi of the code official, the type of construction, fire separation distance and security of the pre do not create a fire hazard. - pdf_text
1 1. A fabricator of structural steel certified by the American Institute of Steel Construction I Certification Program for Structural Steel Fabricators, Standard for Steel Building Structures. - pdf_text
1 1. The total amount on display and in storage in any single control area complies with the maxi allowable quantities as listed in Table 307.1(1) of this code, or - pdf_text
1 1. Portable heating appliances with a self-contained fuel supply. - pdf_text
1 1. Makeup air is not required for exhaust systems installed for the exclusive purpose of space co and intended to be operated only when windows or other air inlets are open. - pdf_text
1 1. Occupancies in Group U. - pdf_text
1 1. At least one accessible building entrance. - pdf_text
1 1. Alternating tread devices in accordance with Section 1011.14. - pdf_text
1 1 Amendments to the 2021 International Building Code - pdf_text
1 1. Wind-borne debris regions: Type A: Full municipality. Type B: Areas within one mile (1.61 km) of the mean high-water line where an Exposure D condition exists upwind at the waterline. - pdf_text
1 1. In buildings equipped throughout with an automatic sprinkler system in accordance with Se - pdf_text
1 1. Group R-1 bed and breakfast establishments. - pdf_text
1 1. The roofing material is warranted/guaranteed by both the roofing material manufacturer an roofing installer for the proposed slope. - pdf_text
1 1. That provides sleeping accommodations to the public for a fee for no more than 16 persons w guestrooms limited to the first or second floor of the structure, - pdf_text
1 1. One-story detached accessory structures used as tool and storage sheds, playhouses and si uses, provided the floor area is not greater than 200 square feet (18.58 m²). - pdf_text
1 1. The entire contents of the tank shall be completely removed and the tank purged of all vapors - pdf_text
1 1. Accessible parking spaces as required by Section 1106. Pursuant to subsection (h) of section - pdf_text
1 1. New envelope assemblies are exempt from the requirements of Section R402.4.1.2. - pdf_text
1 1. Building street address, or other building site identification. - pdf_text
1 1. Toilet rooms or bathing rooms accessed only through a private office, not for common or p use and intended for use by a single occupant, shall be permitted to comply with the spe exceptions in ICC A117.1. - pdf_text
1 1. An accessible route is not required to stories or occupied roofs, or mezzanines that comply Sections 1103.2.15 and 1103.2.16, respectively. - pdf_text
1 1. For rooms with sloped ceilings, the required floor area of the room shall have a ceiling heig not less than 5 feet (1524 mm) and not less than 50 percent of the required floor area shall ha ceiling height of not less than 7 feet (2134 mm). - pdf_text
1 1. Separation distance between membrane structures and tents not used for cooking is not req when the aggregate floor area does not exceed 15,000 square feet (1394 m2). - pdf_text
1 1. All applicable authorities having jurisdiction shall be notified. - pdf_text
1 1. The requirements of the sections indicated within Table N1106.2. - pdf_text
1 1. Inspect Grading of Wood Materials a. Sawn lumber framing b. Structural composite lumber c. Wood structural panels X X X - pdf_text
1 1. Portable heating or cooking appliances with a self-contained fuel supply. - pdf_text
1 1. Design load-bearing values of soils and required bearing layer. - pdf_text
1 1-hour fire-resistance-rated separation. - pdf_text
1 1. Where photovoltaic arrays are installed on only one roof slope of a single ridge roof and is clear access on the opposing slope, and that opposing slope has at least one roof access in accordance with Section R324.6.3, the pathways from the lowest roof edge to the ridge not be required on the roof slope containing the photovoltaic arrays. - pdf_text
1 1. Luminaires with an output of 2,600 lumens or less. - pdf_text
1 1. A difference in elevation between the minimum required floor elevation at the primary entr and the closest vehicular and pedestrian arrival points. - pdf_text
1 1. In Group R-2, R-3 and R-4 occupancies that are required to have Accessible, Type A or Ty dwelling units or sleeping units, at least two percent, but not less than one, of each type of par space provided shall be accessible. - pdf_text
1 1. A Group M fire area exceeds 12,000 square feet (1115 m2). - pdf_text
1 1. An automatic sprinkler system shall not be required in a one- or two-family dwelling constru in accordance with the International Residential Code. - pdf_text
1 1. Habitable basements without sleeping rooms are not required to have emergency escape and re openings when they are provided with two remote, code-compliant stairways. - pdf_text
1 1. Radon-resistant construction technique complying with Section AF103 of this code. - pdf_text
1 1. An emergency escape and rescue opening is not required in a new basement that contai sleeping room with an emergency escape and rescue opening. - pdf_text
1 1. A floor or landing is not required at the top of an interior flight of stairs, including stairs i enclosed garage, provided that a door does not swing over the stairs. - pdf_text
1 1. Protection of freestanding accessory structures with an area of 600 square feet (56 m2) or le light-frame construction, with an eave height of 10 feet (3048 mm) or less shall not be require - pdf_text
1 1. Where the nosing of treads at the side of a flight extend under the edge of a floor opening thr which the stair passes, the floor opening shall be allowed to project horizontally into the req headroom a maximum of 4¾ inches (121 mm). - pdf_text
1 1. Work involving the exterior surfaces of dwellings, such as the replacement of roofing or sidin the addition or replacement of windows or doors, or the addition of a porch or deck. - pdf_text
1 1. Group R-2 occupancies located in stories with only one exit or access to only one exit as perm by Tables 1006.3.4(1) and 1006.3.4(2). - pdf_text
1 1. Factory-built commercial kitchen grease ducts listed and labeled in accordance with UL 1978 - pdf_text
1 1. The material does not comply with the requirements for a noncombustible material. - pdf_text
1 1. Extended below the frost line specified in Table R301.2.(1). - pdf_text
1 1. Makes the means of egress path not readily apparent due to visual or audio distractions. - pdf_text
1 1. Buildings or portions of buildings undergoing additions, alterations, repairs or chang occupancy under a valid permit in accordance with this code. - pdf_text
1 1. All client sleeping rooms shall have an emergency escape and rescue opening in accordance - pdf_text
1 1. New envelope assemblies are exempt from the requirements of Section N1102.4.1.2. - pdf_text
1 1. Generator and transformer rooms separated from the remainder of the building by walls floor/ceiling assemblies having a fire-resistance-rating of not less than 2 hours. - pdf_text
1 1. The identification of size and fabric or material. - pdf_text
1 1. An automatic smoke detection system is not required in buildings that do not have int corridors serving sleeping units and where each sleeping unit has a means of egress door ope directly to an exit access that leads directly to an exit. - pdf_text
1 1. Structures with fewer than four dwelling units. - pdf_text
1 1. Basements with a ceiling height of less than 80 inches (2032 mm) shall not be required to emergency escape and rescue openings. - pdf_text
1 1. Extending a minimum of 42 inches (1067 mm) below finished grade; - pdf_text
1 1 Batterymarch Park Quincy, MA 02169-7471 - pdf_text
1 1. Special inspections and tests are not required for construction of a minor nature or as warrant conditions in the jurisdiction as approved by the building official. - pdf_text
1 1. The fire area exceeds 5,000 square feet (464.5 m2). Exception: Existing restaurants in existing nonsprinklered buildings that were designated Group A-3 under a previous edition of the Connecticut State Building Code that undergo addi alteration or change of occupancy that results in an increase in the restaurant’s fire area, prov the proposed fire area does not exceed 12,000 square feet. - pdf_text
1 1. Assigned to Risk Category I, in accordance with Section 1604.5; - pdf_text
1 1. In accordance with the manufacturer’s instructions. - pdf_text
1 1. Fire separation assemblies shall not be required when the kitchen is protected by a limited sprinkler system. - pdf_text
1 1. Any dwelling unit or sleeping unit is located three or more stories above the lowest level of discharge; - pdf_text
1 1. New fire protection systems shall meet the requirements of Chapter 9 of this code. - pdf_text
1 1. Fixed awnings shall not be required to be designed to resist nominal (Vasd) wind loads in exce - pdf_text
1 1. A fire-resistance rating of ½ hour shall be permitted in buildings equipped throughout wit automatic sprinkler system installed in accordance with NFPA 13. - pdf_text
1 1. Clearance shall not be required from gypsum wallboard or 1/2-inch (12.7 mm) or th cementitious wallboard attached to noncombustible structures provided that a smooth, clean nonabsorbent and noncombustible material is installed between the hood and the gypsu cementitious wallboard over an area extending not less than 18 inches (457 mm) in all direc from the hood. - pdf_text
1 1. Accessibility shall not be required in renovations, additions or alterations to stories in exi buildings above the street floor being converted to Group B provided each story above the s floor contains less than 3,000 square feet (278.7 m2) of total gross area per floor and the street f is renovated or altered to provide accessibility to persons with disabilities. This provision shal apply to stories above the street floor that include the offices of health care providers, muni or state agencies, or passenger transportation facilities or offices located in airport terminals. - pdf_text
1 1. On the ceilings of rooms containing permanently installed fuel-burning heating equipment. - pdf_text
1 1. From a height of 36 inches (914 mm) to 42 inches (1067 mm), guards shall not have ope which allow passage of a sphere 4⅜ inches (111 mm) in diameter. - pdf_text
1 1. Buildings and structures in Risk Category I, in accordance with Table 1604.5. - pdf_text
1 1. Those with a peak design rate of energy usage less than 3.4 British thermal units per hour per s foot (Btu/h.ft2) or 1.0 watts per square foot (watt/ft2) of floor area for space conditioning purp - pdf_text
1 1. As an alternative, self-adhering polymer-modified bitumen underlayment bearing a label indicating compliance with ASTM D1970 and installed in accordance with both the underlay manufacturer’s and roof covering manufacturer’s instructions for the deck material, roof ventilation configuration and climate exposure for the roof covering to be installed, shall be permitted. - pdf_text
1 1. Construction, alteration and repair of any foundation system necessary to provide fo installation of a manufactured home unit. - pdf_text
1 1. On each story in front of doors to the stairways; - pdf_text
1 1. AWC Wood Frame Construction Manual (WFCM). - pdf_text
1 1. The maximum area of a compartment, including the aggregate area of all floors having a com atmosphere, exceeds 30,000 square feet (2787 m²). - pdf_text
1 1. Flat-roof snow load, pf. - pdf_text
1 1. Identify and describe the work to be covered by the permit for which application is made. - pdf_text
1 1. Compartments or rooms with self-closing, self-latching doors. - pdf_text
1 1. Vertical openings that comply with Sections 712.1.1 through 712.1.3, and Sections 712.1.9 thr - pdf_text
1 1. Flights of stairways within dwelling units, Group R-1 bed and breakfast establishments and fligh spiral stairways are permitted to have a handrail on one side only. - pdf_text
1 1. Minor repairs and maintenance work, including replacement of lamps and fuses or the conne of approved portable electrical equipment to approved permanently installed receptacles. - pdf_text
1 1. Buildings or structures where there will be no net increase to the roof insulation R-value. - pdf_text
1 1. The tent is of a hip roof configuration with an eave height of not more than 8 - pdf_text
1 1. Nonrated permanent partition and horizontal assemblies. - pdf_text
1 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyon intended weatherstripping or other infiltration control measures. - pdf_text
1 1. When the roof is changed to a steeper pitch making the roof taller relative to the eave. - pdf_text
1 (cont. 2) (Amd) R406.2 ERI compliance. Compliance based on the Energy Rating Index (ERI) requires tha rated design meet all of the following: - pdf_text
1 (cont. 2) (Add) R320.6.3 Van accessible parking spaces. Pursuant to subsection (h) of section 14-253a o Connecticut General Statutes, parking spaces for passenger vans designated for persons who are blin persons with disabilities shall be as near as possible to a building entrance or walkway and shall be 1 (4877 mm) wide, including 8 feet (2438 mm) of cross hatch. (Add) R320.6.3.1 Van access clearance. Pursuant to subsection (i) of section 14-253a of the Connec General Statutes, each public parking garage or terminal shall have 8 feet 2 inches (2489 mm) ve clearance at a primary entrance and along the route to at least two parking spaces for passenger vans conform to Section R320.6.3 and that have 8 feet 2 inches (2489 mm) of vertical clearance. (Amd) R321.1 Elevators. Where provided, passenger elevators, limited use/limited application elev or elevators installed in private residences shall comply with ASME A17.1 and shall be install accordance with regulations adopted under authority of section 29-192 of the Connecticut General Stat Where the provisions of this section conflict with the regulations adopted under chapter 538 requirements of the regulations shall prevail. (Amd) R324.3 Photovoltaic systems. Photovoltaic systems shall be designed and installed in accord with Sections R324.3.1 through R324.7.2.5, the manufacturer’s installation instructions and NFPA 70 - pdf_text
1.0 1.0 inch water column, but shall not exceed the positive pressure capability of the system and compo under test. No smoke shall emit from any exterior surface of the duct. (Add) 506.3.2.5.2 Air test. The air test shall be performed by sealing the entire duct system from the exhaust opening(s) to the duct termination. The sealed duct system shall then be pressurized to a mini pressure of 1.0 inch (249 Pa) water column and shall be required to hold the initial set pressure f minimum of 20 minutes. - pdf_text
1.1 1.1. Those with a peak design rate of energy usage less than 3.4 Btu/h□ ft2 or 1.0 watt square foot (watt/ft2) of floor area for space conditioning purposes. - pdf_text
1.1 1.1. Those with a peak design rate of energy usage less than 3.4 Btu/h · ft2 (10.7 W/m2) o watt/ft2 of floor area for space-conditioning purposes. - pdf_text
1.2 1.2. Those that do not contain conditioned space. - pdf_text
1.2 1.2. Those that do not contain conditioned space. - pdf_text
1.3 1.3. Buildings and structures for which heating and cooling is supplied solely by utilizati non-purchased renewable energy sources including, but not limited to, on-site wind, o water or on-site solar power, or wood-burning heating appliances that do not rely on ba heat from other purchased, non-renewable sources. - pdf_text
1.3 1.3. Buildings and structures for which heating and cooling is supplied solely by utilizati nonpurchased renewable energy sources including, but not limited to, on-site wind site water or on-site solar power, or wood-burning heating appliances that do not re backup heat from other purchased, nonrenewable sources. - pdf_text
10 10. Decks and ramps not exceeding 200 square feet (18.58 m2) in area, that are not more than 30 in (762 mm) above grade at any point, are not attached to a dwelling, do not require guards, an not serve the exit door required by Section R311.4. - pdf_text
10 10. In recreational facilities, lockers that are required to be accessible in accordance with Se - pdf_text
10 10 Cast-iron pipeb - pdf_text
10 10. Shade cloth structures constructed for nursery or agricultural purposes and not including se systems. - pdf_text
10 10. Terminate not more than 6 inches (152 mm) and not less than two times the discharge diameter above the floor or waste receptor flood level rim and cut at a 45-degree angle. - pdf_text
10 10. Identify a registered design professional in responsible charge as required by Section 107.3. - pdf_text
10 10 Cross-linked polyethylene (PEX) pipe, 1 inch and smaller - pdf_text
10 10. Exit access stairways serving mezzanines complying with the provisions of Section 505. (Add) 1020.2.2 Group R-1 bed and breakfast establishments. A fire-resistance rating is not req for corridors in Group R-1 bed and breakfast establishments. Doors leading from guestrooms corridors or hallways in Group R-1 bed and breakfast establishments shall be equipped with self-clo devices. (Amd) Table 1020.2 Corridor Fire-Resistance Rating Amend final row as follows: Add new footnote as follows: e. For Group I-4 day care facilities that satisfy Section 903.2.6, Exception 2, a corridor resistance rating of zero (0) is permitted. - pdf_text
10 10 Brass pipe - pdf_text
10 10 Cast-iron pipe - pdf_text
10 10. Terminate not more than 6 inches (152 mm) above and not less than two times the discha pipe diameter above the floor or flood level rim of the waste receptor and cut at a 45 degree angle. CHAPTER 6 - WATER SUPPLY AND DISTRIBUTION (Add) 608.1.1. Connection to a public water supply system. Connections to a public water supply system shall be in accordance with the Public Health Code of the State of Connecticut adopted pursua to section 19a-36 of the Connecticut General Statutes and the requirements of the water system opera (Add) 608.1.2 Required Notification to water company and building official. Pursuant to section - pdf_text
10 10 pounds (4.54 kg) or less refrigerant or that are actuated by motors of 1 horsepower (746 W) or less. - pdf_text
10 10 Steel pipe - pdf_text
10-410 10-410 of the Connecticut General Statutes, which have been classified as such in the State Regist Historic Places, as long as the provisions of subsection (b) of section 29-259 of the Connecticut Ge Statutes are adhered to and provided that such exemptions shall not affect the safe design, us construction of such property. - pdf_text
100 100-year hourly rainfall rate and shall be 6.0 inches. R = 5.2(ds + dh) (Equation 16-19) For SI: R = 0.0098(ds + dh) where: dh = Additional depth of water on the undeflected roof above the inlet of secondary drainage system a design flow (in other words, the hydraulic head), in inches (mm). - pdf_text
1006.3 1006.3 for stories or occupied roofs. Exception: Buildings of Group R-1 bed and breakfast establishments shall only be required to one exit. (Add) 1006.2.2.7 Group I-4 day care means of egress. Group I-4 facilities, rooms or spaces where is provided for more than 10 children who are 3 years of age or younger shall have access to not less two exits or exit access doorways. (Amd) 1008.2 Illumination required. The means of egress from a room or space, including the discharge, shall be illuminated at all times the building served by the means of egress is occupied. Exceptions: - pdf_text
101.2 101.2, which are equal to or less than 24 inches (610 mm) deep, do not exceed 5,000 gallon - pdf_text
1030.17.4 1030.17.4 shall not have openings which allow passage of a sphere 4 inches in diameter (102 up to a height of 26 inches (660 mm). From a height of 26 inches (660 mm) to 42 inches ( mm) above the adjacent walking surfaces, guards shall not have openings which allow passa a sphere 8 inches (203 mm) in diameter. - pdf_text
1030.6.3 1030.6.3 indicated for level or ramped aisles for means of egress components other than stair where the entire path for means of egress from the seating to the exit discharge is open t outdoors. (Amd) 1006.1 General. The number of exits or exit access doorways required within the means of e system shall comply with the provisions of Section 1006.2 for spaces, including mezzanines, and Se - pdf_text
1030.6.3 1030.6.3 indicated for stepped aisles for exit access or exit stairways where the entire pat means of egress from the seating to the exit discharge is open to the outdoors. - pdf_text
105 105 Amendments to the 2021 International Swimming Pool & Spa Code - pdf_text
107-1926 107-1926 of the Regulations of Connecticut State Agencies. (Amd) 108.1 General. The building official may issue a permit for temporary structures and temp uses. Such permits shall be limited as to time of service but shall not be permitted for more than 180 The building official may grant a single 180-day extension for demonstrated cause. Exception: Tents, canopies and other membrane structures erected for a period of fewer than 180 shall comply with Section 3103 of this code. (Amd) 108.3 Temporary power. The building official is authorized to give permission to tempor supply utilities before an installation has been fully completed and the final certificate of approval has issued. The part covered by the temporary certificate shall comply with the requirements specifie temporary lighting, heat or power in this code and in NFPA 70, National Electrical Code. (Amd) 109.2 Schedule of permit fees. Each municipality shall establish a schedule of fees for construction document review, building permit, certificate of approval and certificate of occupanc schedule of adopted fees shall be posted in the building department for public view. (Del) 109.4 Work commencing before permit issuance. Delete without substitution. (Add) 110.1.1 Posting of required inspections. A schedule of required inspections shall be compile the building official. The schedule shall be posted in the building department for public view. - pdf_text
11 11. Identify deferred submittals, including a deferred submittal schedule, as required by Se - pdf_text
11 11. Repairs that are limited to 25 percent of roof covering and building siding within one calendar Electrical: - pdf_text
11 11. Swings and other playground equipment. - pdf_text
11 11. Accessible portable toilet and bathing units. - pdf_text
1104.3 1104.3. Exception: Exterior spaces less than 60 inches in depth. (Amd) 1104.3.1 Location. At least one accessible route shall connect all spaces and elements that part of the unit. Accessible routes shall coincide with or be located in the same area as the general circul path. Exception: An accessible route is not required to unfinished attics and unfini basements that are part of the unit. - pdf_text
1110.2.1 1110.2.1 of the International Building Code shall be provided. At the inaccessible bathing ro directional signs indicating the location of the nearest accessible bathing room shall be provided. T directional signs shall include the International Symbol of Accessibility and sign characters shall me visual character requirements in accordance with ICC A117.1. - pdf_text
1110.2.4 1110.2.4 and 1110.2.5, at least one of each type of fixture, element, control or dispenser in each acces toilet room and bathing room shall be accessible. - pdf_text
113 113 Amendments to the 2021 International Residential Code - pdf_text
12 12 Copper or copper-alloy tubing (11/4 inches in diameter and smaller) - pdf_text
12 12. Accessible means of egress stairways. - pdf_text
12 12. Window awnings in Group R-3 and U occupancies, supported by an exterior wall that do not pr more than 54 inches (1372 mm) from the exterior wall and do not require additional support. - pdf_text
12 12 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. The maximum horizontal spacing of cast-iron pipe hangers shall be increased to 10 feet wher foot lengths of pipe are installed. b. For sizes 2 inches and smaller, a guide shall be installed midway between required vertical sup Such guides shall prevent pipe movement in a direction perpendicular to the axis of the pipe. c. The maximum horizontal spacing of PP or PP-RCT pipe hangers shall be increase manufacturer's installation requirements based on maximum operating temperature design. CHAPTER 28 – WATER HEATERS (Amd) P2804.6.1 Requirements for discharge pipe. Amend item 10. as follows: - pdf_text
12 12 Copper or copper-alloy tubing, 11/4-inch diameter and smaller - pdf_text
12 12 Copper or copper-alloy tubing - pdf_text
12 12 Steel tubing - pdf_text
13 13. Nonfixed and movable fixtures, cases, racks, counters and partitions not higher than 5 feet 9 in (1753 mm) and not containing any electrical, plumbing or mechanical equipment. - pdf_text
13 13. Accessible grade-level exits required by Section 1013.1.1. (Add) 1112.6 Interior signage. Interior signs, when provided, that designate permanent rooms and sp shall be raised text characters and braille, designed and located in accordance with ICC/ANSI A1 Mounting location for signage shall be such that any person approaching the signage will not enco protruding objects, or stand within the swing of any door. CHAPTER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (Amd) 1507.11.1 Slope. Modified bitumen roofing shall have a design slope of a minimum of one-f unit vertical in 12 units horizontal (2-percent slope) for drainage. Exception: A minimum design slope of one-eighth unit vertical in 12 units horizontal shall be perm when the following two conditions are met: - pdf_text
14 14. Portable grandstands or bleachers providing seating for fewer than 100 persons when lo outside of a building. Electrical: - pdf_text
140 140 mph (62.6 m/sec) or greater. (Del) 1705.12.1 Structural wood. Delete section. (Del) 1705.12.2 Cold-formed steel light-framed construction. Delete section. (Del) 1705.12.3 Wind-resisting components. Delete section. CHAPTER 18 – SOILS AND FOUNDATIONS (Amd) Table 1806.2 PRESUMPTIVE LOAD-BEARING VALUES For SI: 1 pound per square foot = 0.0479 kPa, 1 pound per square foot per foot = 0.157 kPa/m a. Coefficient to be multiplied by the dead load. b. Cohesion value to be multiplied by the contact area, as limited by Section 1806.3.2 (Add) 1807.2.1.1 Guards. Retaining walls with a difference in height between the finished grade at th of the wall and the finished grade at the bottom of the wall that is greater than 4 feet (1219 mm) sha provided with guards complying with Sections 1015.3, 1015.4 and 1607.8 when there is a walking sur parking lot or driveway on the high side located closer than 2 feet (610 mm) to the nearest side o retaining wall. For the purpose of this section, grass, planting beds or landscaped areas shall n considered a walking surface. - pdf_text
1609 1609. (Add) 3103.5.5.3 Tents and membrane structures greater than 7,500 square feet. Tents and mem structures greater than 7,500 square feet (697 m2) shall be designed and constructed to comply Sections 1606 through 1609. (Add) 3103.5.5.4 Tents and membrane structures with an occupant load greater than 1,000. Tent membrane structures with an occupant capacity greater than 1,000 persons shall be designed constructed to comply with Sections 1606 through 1609. (Add) 3103.5.5.5 Other tents and membrane structures. Other tents and membrane structures tha erected for a period not exceeding 60 consecutive days shall be designed to resist an allowable design speed (Vasd) of not less than 45 mph (20.1 m/s). Tents and membrane structures that will be in se between November 15 and April 15 shall be capable of supporting snow loads complying with Se - pdf_text
1609 1609 in addition to the applicable dead loads. The provisions for “unobstructed slippery roofs” in Fi - pdf_text
1613 1613. An additional fire pump shall not be required for the secondary water supply unless needed to pr the minimum design intake pressure at the suction side of the fire pump supplying the automatic spri system. The secondary water supply shall have a duration of not less than 30 minutes as determined b occupancy hazard classification in accordance with NFPA 13. (Amd) 404.1 General. The provisions of Sections 404.1 through 404.11 shall apply to buildings contai atriums. Atriums are not permitted in buildings or structures classified as Group H. Exceptions: - pdf_text
1705 1705 X a. Inspections of holes and notches to be performed after electrical, mechanical and plumbing rough-in inspections. b. Applies to wood structural panels and gypsum board panels. - pdf_text
180 180 days. The building official is authorized to grant a single 180-day extension for demonstrated cau Exceptions: The following shall be exempt from permit requirements: - pdf_text
180 180 days, for commencement of work under permits issued to abate unsafe conditions pursua - pdf_text
1810 1810 of the 2021 International Building Code portion of the 2022 Connecticut State Building Code. (Add) R404.6.1 Special inspections of deep foundations. Special inspections of deep foundations be performed in accordance with Sections 1705.7 through 1705.10, as applicable, of the 2021 Internat Building Code portion of the 2022 Connecticut State Building Code. (Add) R405.3 Above-grade drainage. Above-grade drainage systems, including but not limited to, g and downspouts, roof drains and yard drains, shall not be connected to the foundation drainage syste CHAPTER 6 – WALL CONSTRUCTION (Amd) Table R602.7(1), Footnote e. Use 30 psf ground snow load for cases in which ground snow lo less than 30 psf and the roof live load is equal to or less than 20 psf. For ground snow loads betwee and 50 psf, linear interpolation is permitted. (Amd) Table R602.7(3), Footnote b. Tabulated values assume #2 grade lumber, wet service and inc for refractory species. Use 30 psf ground snow load for cases in which ground snow load is less tha psf and the roof live load is equal to or less than 20 psf. For ground snow loads between 30 and 5 linear interpolation is permitted. CHAPTER 8 – ROOF-CEILING CONSTRUCTION - pdf_text
1810 (cont. 2) (Amd) R802.4.1 Rafter size. - Rafters shall be sized based on the rafter spans in Tables R802.4.1(1) thr R802.4.1(8). For ground snow loads other than those cited in Tables 802.4.1(3) through 802.4.1(8), r spans may be determined using linear interpolation. Rafter spans shall be measured along the horiz projection of the rafter. For other grades and species and for other loading conditions, refer to the STJR. (Amd) R802.10.2.1 Applicability limits. The provisions of this section shall control the design of roof framing when snow controls for buildings, not greater than 60 feet (18 288 mm) in length perpendi to the joist, rafter or truss span, not greater than 36 feet (10 973 mm) in width parallel to the joist, raft truss span, not more than three stories above grade plane in height with each story not greater than 1 (3048 mm) high, and roof slopes not smaller than 3:12 (25-percent slope) or greater than 12:12 (100-pe slope). Truss roof framing constructed in accordance with the provisions of this section shall be limit sites subjected to a maximum design wind speed of 140 miles per hour (63 m/s), Exposure B or C, maximum ground snow load of 70 psf (3352 Pa). For consistent loading of all truss types, roof snow is to be computed as: 1.0 pg. - pdf_text
1945 1945, except as may be necessary for the safety of life or property. The use of a building or premises not be deemed to have changed because of a temporary vacancy or change of ownership or tenancy. Exceptions: - pdf_text
1945 1945, except as may be necessary for the safety of life or property. The use of a building or premises not be deemed to have changed because of a temporary vacancy or change of ownership or tenancy. - pdf_text
2 2. Describe the land on which the proposed work is to be done by legal description, street addre similar description that will readily identify and definitely locate the proposed building or wo - pdf_text
2 2. A certificate of occupancy is not required for work exempt from permit requirements under Se R105.2 - pdf_text
2 2. The building in which the facility is located is limited to two stories above grade plane and 4 in height, - pdf_text
2 2. A manufacturer of metal building systems accredited by the ICC International Accredit Service (IAS) in accordance with accreditation criteria IAC-AC-472. - pdf_text
2 2. When an additional story is added to any portion of the structure. - pdf_text
2 2. Handrails otherwise required to comply with Section 1011.11 of the International Building shall not be required to comply with the requirements of Section 1014.6 of the Internati Building Code regarding full extension of the handrails where such extensions would be hazar because of plan configuration. - pdf_text
2 2. These requirements shall not apply to roofs with slopes of 2 units vertical in 12 units horiz (17-percent slope) or less. - pdf_text
2 2. Wall assemblies need not extend through attic spaces when the ceiling is protected by not less ⅝-inch (15.9 mm) Type X gypsum board, an attic draft stop constructed as specified in Se R302.12.1 is provided above and along the wall assembly separating the dwellings and structural framing supporting the ceiling is protected by not less than ½-inch (12.7 mm) gy board or equivalent. (Add) R302.3.2 Sound transmission. Wall and floor-ceiling assemblies separating dwelling units comply with Appendix AK. (Amd) R302.5.3 Other penetrations. Penetrations into or through the separation required in Table R3 shall be protected as required by Section R302.11, Item 4. (Amd) R302.6 Dwelling/garage fire separation. The garage shall be separated as required by T R302.6 except that wood structural members of the minimum dimension specified in the 2021 Internati Building Code for Type IV-HT construction shall be acceptable without further protection. Openin garage walls shall comply with Section R302.5. Attachment of gypsum board shall comply with T R702.3.5. The wall separation provisions of Table R302.6 shall not apply to garage walls that perpendicular to the adjacent dwelling unit wall. (Amd) TABLE R302.6 DWELLING/GARAGE SEPARATION For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. If building is sprinklered in accordance with Section R313, then not less than ½-inch gypsum board or equival required. - pdf_text
2 2. An emergency escape and rescue opening is not required in a new basement where there i emergency escape and rescue opening in an existing basement that is accessed from the basement. - pdf_text
2 2. Maximum value indicated in Section 406.5. - pdf_text
2 2. Ships ladders in accordance with Section 1011.15. - pdf_text
2 2. Fire partition. - pdf_text
2 2. Rooms or spaces that have a door leading directly to the outside of the building. - pdf_text
2 2. Where photovoltaic arrays are installed on only one side of the hip rafter of a hipped roo there is clear access on the opposing slope, and that opposing slope has at least one roof a point in accordance with Section R324.6.3, the pathways from the lowest roof edge to the shall not be required on the roof slope containing the photovoltaic arrays. - pdf_text
2 2. The fuel tank vent line shall remain intact and open. - pdf_text
2 2. The provisions of Section 404 shall not apply to vertical openings in Group R-1 bed and brea establishments. - pdf_text
2 2. Retractable awnings shall not be required to be designed to resist wind or snow loads. (Amd) 3107.1 General. Signs shall be designed, constructed and maintained in accordance with Appe H of this code. (Add) 3109.1.1 Health Department regulations. No person shall construct, substantially alt reconstruct a swimming pool until the construction documents and water discharge provisions have approved by the Department of Public Health, in accordance with the regulations adopted pursua - pdf_text
2 2. In existing buildings, basements and attics being converted to habitable space without slee rooms are not required to have emergency escape and rescue openings. - pdf_text
2 2. Manual fire alarm boxes are not required where the building is equipped throughout wit automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2 and the occu notification appliances will automatically activate throughout the notification zones up sprinkler water flow. - pdf_text
2 2. At least one accessible route from an accessible building entrance to primary function areas. - pdf_text
2 2. The 4-inch-wide (102 mm) strips of self-adhering polymer-modified-bitumen membrane are required for roofs sheathed with lumber having a nominal width of less than 3 feet. (Amd) TABLE R905.2.4.1 CLASSIFICATION OF ASPHALT ROOF SHINGLES For SI: 1 foot = 304.8 mm; 1 mph = 0.447 m/s. a. The standard calculations contained in ASTM D7158 assume Exposure Category B or C and buildi height of 60 feet or less. Additional calculations are required for conditions outside of these assumpti CHAPTER 11 [RE] – ENERGY EFFICIENCY (Amd) N1101.4 (R102.1.1) Above-code programs. The State Building Inspector and the Codes Standards Committee may deem a national, state or local energy efficiency program to exceed the en efficiency required by this chapter. Such energy efficiency program may include, but not be limited t Leadership in Energy and Environmental Design rating system; the Green Globes USA progra established by the Green Building Initiative; the National Green Building Standard, as established b National Association of Home Builders; or an equivalent rating system approved in accordance with se - pdf_text
2 2. This section is not applicable to toilet and bathing rooms that serve dwelling units or slee units that are not required to be accessible by Section 1108. - pdf_text
2 2. Automatic sprinkler system shall not be required in a townhouse constructed in accordance the International Residential Code. - pdf_text
2 2. The Enclosure Classification for the tent shall be Enclosed, Partially Open or as defined in Section 26.2 of ASCE 7. - pdf_text
2 2. An automatic smoke detection system is not required in Group R-1 bed and brea establishments (see Section 907.2.11.1.1). (Amd) 907.2.9.1 Manual fire alarm system. A manual fire alarm system that activates the occu notification system in accordance with Section 907.5 shall be installed in Group R-2 occupancies wh - pdf_text
2 2. The triangular openings at the open side of a stair, formed by the riser, tread and bottom rail not allow passage of a sphere 6 inches (152 mm) in diameter. - pdf_text
2 2. A child-height water closet. - pdf_text
2 2. Any additional snow drift loads induced on the roof of the adjacent existing building are less t the magnitude of the snow drift loads that would have already existed on the roof of the adja existing building. - pdf_text
2 2. In Group R-1, R-2 or R-3 occupancies, exit access stairways and ramps connecting four stori less serving and contained within a single residential dwelling unit or sleeping unit or live/ unit. - pdf_text
2 2. Area of 600 square feet (56 m2) or less for light-frame construction or 400 square feet (37 m less for other than light-frame construction; and - pdf_text
2 2. Constructed in accordance with Section R403.3. - pdf_text
2 2. Carbon monoxide detection shall not be required in dwelling units and sleeping units wh carbon monoxide detector is provided in one of the following locations: - pdf_text
2 2. Unless otherwise required by the building official, special inspections and tests are not require Group U occupancies that are accessory to a residential occupancy including, but not limite those listed in Section 312.1. - pdf_text
2 2. Buildings and structures in Risk Category II in accordance with Table 1604.5, which are in exposure category B or C in accordance with Section 1609.4.3, are in Seismic Design Catego or B, and are not more than three stories high. (Add) TABLE 1705.5 REQUIRED SPECIAL INSPECTIONS OF WOOD CONSTRUCTION TYPE CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECTION IB REFER - pdf_text
2 2. Doors that swing into the compartment or room. (Add) 1110.2.4.2 Single-occupancy toilet. Required accessible toilet rooms designed for single occup in other than Group R shall meet the requirements of ICC/ANSI A117.1. Each such room shall co both toilet and lavatory, shall have a lever handle privacy lockset and shall have an emergency call sy that actuates a visible and audible alarm in a normally occupied area. An alarm pull switch, identified emergency instruction, shall be provided within 3 feet of the water closet with a pull cord extendi within 12 inches of the floor. (Add) 1110.9.1 Limited-use/limited-application elevators. Limited-use/limited-application elev shall be permitted to be installed in new construction in the same locations specified in Section 11 Limited-use/limited-application elevators shall be installed in accordance with the Connecticut Safety for Elevators and Escalators, adopted under authority of section 29-192 of the Connecticut General Sta and with provisions of this code adopted under authority of section 29-200 of the Connecticut Ge Statutes. - pdf_text
2 2. Log homes designed in accordance with ICC 400. (Add) R402.2.13 Foamed-in-place insulating material. Pursuant to section 29-277 of the Connec General Statutes, foamed-in-place insulating material, except urethane foam insulation or styrene insulation, shall not be sold or installed in this state on or after May 28, 2013, unless the manufactur supplier has certified to the State Building Inspector that the material complies with the provisions o section. - pdf_text
2 2. Existing Group R-2 buildings or structures on a site or within a complex shall not contr to the total number of units on a site. (Amd) 1108.7.2 Multistory units. A multistory dwelling unit or sleeping unit that is not provided elevator service is not required to be a Type B unit. Where a multistory unit is provided with ext elevator service to only one floor, the floor provided with elevator service shall be the primary entry t unit shall comply with the requirements for a Type B unit and, where provided within the unit, provis for living, sleeping, eating, cooking and a complete toilet and bathing facility shall be on that floor. W a multistory unit is provided with external elevator service to more than one floor of the unit, one shall be the primary entry to the unit and shall comply with the requirements for a Type B unit, provi provisions for living, sleeping, eating, cooking and a complete toilet and bathing facility on that floor. (Amd) 1110.2 Toilet and bathing facilities. Each toilet room and bathing room shall be accessible. W a floor level is not required to be connected by an accessible route, the only toilet rooms or bathing r provided within the facility shall not be located on the inaccessible floor. Except as provided for in Sec - pdf_text
2 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, bu sealed beyond intended infiltration control measures. - pdf_text
2 2. Luminaires intended to illuminate the façade of buildings or to illuminate other objects inclu but not limited to, flagpoles, landscape and water features, statuary and works of art. - pdf_text
2 2. Radon mitigation preparation construction shall not be required in existing buildings underg repair, addition or alteration. In the case of an addition to an existing building, this exception applies to the new construction. (Add) AF102.2 Definitions. Add or amend the following definitions. (Add) VENT PIPE. Not less than a 3-inch (76 mm) diameter ABS or PVC gastight pipe extending the gas permeable layer through the roof. SECTION AF103 PASSIVE RADON-RESISTANT SYSTEM REQUIREMENTS (Amd) AF103.5.3 “T” fitting and vent pipe. A 3- or 4-inch (76 mm or 102 mm) “T” fitting sha inserted beneath the soil-gas-retarder and be connected to a vent pipe. The vent pipe shall extend thr the conditioned space of the dwelling and terminate not less than 12 inches (305 mm) above the roof location not less than 10 feet (3048 mm) away from any window or other opening into the conditi spaces of the building that is less than 2 feet (610 mm) below the exhaust point. The vent pipe shall b same diameter throughout its length and shall be supported in accordance with Section P2605. - pdf_text
2 2. The registered design professional responsible for the design of the roof structure certifies th roof structure is designed to support all loads, including any additional loads resultant t reduced slope. (Amd) 1507.12.1 Slope. Thermoset single-ply membrane roofs shall have a design slope of a minimu one-fourth unit vertical in 12 units horizontal (2-percent slope) for drainage. Exception: A minimum design slope of one-eighth unit vertical in 12 units horizontal shall be perm when the following two conditions are met: - pdf_text
2 2. Emergency escape and rescue openings are not required from basements or sleeping ro that have an exit door or exit access door that opens directly into a public way or to a y court or exterior egress balcony that opens to a public way. - pdf_text
2 2. Any dwelling unit or sleeping unit is located more than one story below the highest level of discharge of exits serving the dwelling unit or sleeping unit; or - pdf_text
2 2. Construction, installation, addition, alteration, repair or maintenance of the building se equipment necessary for connecting manufactured homes to water, fuel or power supplies sewage systems. - pdf_text
2 2. One door shall open directly to the exterior at the level of exit discharge from the sleeping hallway or a client sleeping room. (Add) 407.14.1.4 Size of doors. The minimum width of all door openings shall provide a clear width inches (863 mm). Clear openings of doorways with swinging doors shall be measured between the fa the door and the stop, with the door open 90 degrees (1.57 rad). (Add) 407.14.1.5 Door latches. Every door latch to closets, storage areas and other similar spaces or areas shall be such that the clients can open the door from inside the space or area. (Add) 407.14.1.6 Client sleeping room and bathroom doors. Client sleeping room and bathroom locks shall be designed to allow the opening of the locked door from the outside by an opening d readily accessible by staff in an emergency. - pdf_text
2 2. Walls separating tenant spaces in covered and open mall buildings as required by Section 402.4 - pdf_text
2 2. Centrally located within the first room or area served by the first air supply register by each duct leaving a fuel-burning, forced-air furnace. (Add) 915.2.3.2 Signage. A sign shall be provided at all entrances to such rooms indicating that ca monoxide detectors are located within the space. (Add) 915.4.5 Interconnection of alarms. Carbon monoxide alarms shall be interconnected in accord with Section 9.6.4 of NFPA 720. (Add) 915.5.4 Group E alarm notification. Carbon monoxide detectors shall be connected to the bui fire alarm signaling system as a separate zone or zones. Such alarms shall activate a supervisory sig the main control unit and any remote annunciators. Such alarms shall not activate the building evacu alarm. (Amd) 915.6 Maintenance. Carbon monoxide alarms and carbon monoxide detection systems sha maintained in accordance with NFPA 720. Carbon monoxide alarms and carbon monoxide detectors become inoperable, begin producing end-of-life signals or have reached the manufacturer’s replace date shall be replaced. - pdf_text
2 2. In the corridors of all floors occupied by the day care facilities; and - pdf_text
2 2. Fire command centers. - pdf_text
2 2. Tents open on all sides which comply with all of the following: - pdf_text
2 2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures, and the remova reinstallation of water closets, provided such repairs do not involve or require the replaceme rearrangement of valves, pipes or fixtures. (Amd) R105.3.1 Action on application. Pursuant to section 29-263 of the Connecticut General Stat the building official shall examine or cause to be examined applications for permits and amendm thereto within 30 days after filing and either issue or deny a permit within such 30-day period. I application or construction documents do not conform to the requirements of this code and applicable l the building official shall reject such application in writing, stating the reasons therefor. If the buil official is satisfied that the proposed work conforms to the requirements of this code and applicable l the building official shall issue a permit as soon as practicable. (Add) R105.3.1.1.1 Wind design criteria for existing structures. For structures where the proposed is determined to be a substantial improvement or restoration under Section R105.3.1.1 and having a Exposure D, structural elements that are uncovered shall be required to be improved to meet the wind s design criteria in Section R301.2.1. - pdf_text
2 2. Replacement of any minor part that does not alter approval of equipment or make such equip unsafe. - pdf_text
2 2. In Group I-1 and R-1 occupancies, accessible parking shall be provided in accordance with T - pdf_text
2 2. For buildings with more than seven units, a sampling protocol is allowed by an approved party. The sampling protocol requires the first seven units to be tested without any fail Upon successful testing of those initial seven units, remaining units can be sampled at a ra - pdf_text
2 2. Portable ventilation appliances. - pdf_text
2 2. Fences, other than swimming pool barriers, not over 7 feet (2134 mm) high. - pdf_text
2 2. The opening between adjacent treads is not limited on spiral stairways. - pdf_text
2 2. Child washing and diaper changing facilities shall be permitted in lieu of bathtubs or showers Group I-4 child care occupancies. - pdf_text
2 2. Buildings or structures designed under the 1978, 1987, 1994 or latter editions of the Connec State Building Code. - pdf_text
2 2. Buildings and structures of any occupancy consisting of three stories or less not other exempted from the requirements of this chapter shall be exempt if each story above and belo street floor contains less than 3,000 square feet (278.7 m2) of total gross area and the street f is designed, renovated or altered to provide accessibility to persons with disabilities. This provi shall not apply to stories above or below the street floor that include the offices of health providers, municipal or state agencies or passenger transportation facilities or offices locat airport terminals or mercantile facilities having five or more tenant spaces. - pdf_text
2 2. The width of existing stairways serving existing unfinished attics or existing unfinished basem being converted to habitable space or replacement stairways within existing dwellings shall n less than 32 inches (813 mm) in clear width at all points above the permitted handrail height below the required headroom height. The clear width of stairways at and below the handrail he including treads and landings, shall not be less than 28 inches (711 mm) where a handr installed on one side and 24 inches (610 mm) where handrails are provided on both sides. - pdf_text
2 2. Design capacities (axial, including uplift, and lateral) and required bearing layer for foundations. (Add) 1607.3.1 Group R-1 bed and breakfast establishments. Live loads shall comply wit requirements of Table 1607.1 for one- and two-family dwellings. (Add) 1608.1.1 Flat roof snow loads. The flat roof snow load, pf, shall be calculated in accordance - pdf_text
2 2. Where buildings will not be heated and fire protection systems will be exposed to fre temperatures, fire alarm and sprinkler systems may be placed out of service and standpipes m maintained as dry systems (without an automatic water supply) provided the building ha contents or storage, and windows, doors and other openings are secured to prohibit entr unauthorized persons. (Add) 118.2.3 Fire separation. Fire-resistance-rated partitions, fire barriers and fire walls separ vacant tenant spaces from the remainder of the building shall be maintained. (Add) 118.3 Removal of combustibles. Persons owning, or in charge or control of, a vacant buildi portion thereof, shall remove all accumulations of combustible materials and flammable or combus waste or rubbish from such space. The premises shall be maintained clear of waste or hazardous mate Exceptions: - pdf_text
2 2. A safe workplace shall be maintained throughout the prescribed activities. - pdf_text
2 2. Maximum value indicated in Section N1106.5. (Amd) N1106.5 (R406.5) ERI-based compliance. Compliance based on an ERI analysis requires th rated proposed design and confirmed built dwelling unit be shown to have an ERI or a Home Energy R System (HERS) value less than or equal to 55. Compliance shall be demonstrated without the use o site renewable energy. (Del) Table N1106.5 (R406.5) MAXIMUM ENERGY RATING INDEX. Delete without substituti - pdf_text
2 2. Snow exposure factor, Ce. - pdf_text
2 2. The names and addresses of the manufacturers of the tent or air-supported structure. - pdf_text
2 2. The ceiling height above bathroom and toilet room fixtures shall be such that the fixture is cap of being used for its intended purpose. A shower or tub equipped with a showerhead shall ha ceiling height of not less than 6 feet 8 inches (2032 mm) above an area of not less than 30 in (762 mm) by 30 inches (762 mm) at the showerhead. - pdf_text
2 2. Installation, alteration or repairs of plumbing, mechanical or electrical systems are exempt the requirements of this section. (Add) R314.2.3 During construction. Pursuant to section 29-315b of the Connecticut General Statut whenever a dwelling is occupied during interior alterations or additions requiring a building permit, t temporary installation of battery-operated smoke alarms shall be required in the vicinity of such alterations or additions for the duration of construction activities. A combined smoke and carbon monoxide alarm may be installed to comply with Section R315.2.3 and this section. (Amd) R314.4 Interconnection. Where more than one smoke alarm is required to be installed with individual dwelling unit in accordance with Section R314.3, the alarm devices shall be interconnect such a manner that the actuation of one alarm will activate all of the alarms in the individual unit. Phy interconnection of smoke alarms shall not be required where listed wireless alarms are installed an alarms sound upon activation of one alarm. Exception: Interconnection of smoke alarms in existing areas shall not be required w alterations or repairs do not result in removal of interior wall or ceiling finishes exposin structure. - pdf_text
2 2. Type 1 hoods listed and labeled for clearances less than those required in Section 507.2 accordance with UL 710 shall be installed with the clearances specified by such listings. (Add) 507.2.6.1 Clearance reduction. The clearances required by Section 506.3.6 shall be permitted reduced in accordance with Section 308. CHAPTER 6 – DUCT SYSTEMS (Amd) 606.2 Where required. Smoke detectors shall be installed where indicated in Sections 606.2 - pdf_text
2 2. Membrane structures or tents need not be separated from buildings when all of the follo conditions are met: - pdf_text
2 2. Installation, alteration or repairs of plumbing systems. - pdf_text
2 2. Rooms or spaces that have a door leading directly to the outside of the building. (Amd) 1031.3.2 Minimum dimensions. The minimum net clear opening height dimension shall b inches (610 mm). The minimum net clear opening width dimension shall be 20 inches (508 mm). Th clear opening dimensions shall be the result of normal operation of the opening. Exception: In existing buildings undergoing a change of occupancy to Group R-1 bed and brea establishments, the net clear opening dimensions may be obtained by removal of the sash withou use of a key or tool provided that the instructions for the removal of the sash are clearly posted o inside of the guestroom door. (Amd) 1031.3.3 Maximum height from floor. Emergency escape and rescue openings shall hav bottom of the clear opening not greater than 44 inches (1118 mm) measured from the floor. Exception: In an existing building undergoing a change of use, the 44-inch (1118 mm) maxi height may be measured vertically above a fixed, permanent platform, step or steps whose mini width shall equal or exceed the operable width of the opening and shall be centered on such ope Any stairs or steps shall comply with Section 1011.5. CHAPTER 11 – ACCESSIBILITY (Amd) 1103.2.11 Group R-1 bed and breakfast establishments. Group R-1 bed and brea establishments are not required to be accessible. - pdf_text
2 2. Existing buildings undergoing alterations or installation of replacement windows shal permitted to utilize removable sash to achieve the required minimum net clear openings. removable sash shall be capable of being removed without the use of a key or tool. (Amd) R310.2.3 Maximum height from floor. Emergency escape and rescue openings shall hav bottom of the clear opening not greater than 44 inches (1118 mm) above the floor. Exception: The 44-inch (1118 mm) maximum sill height shall be permitted to be measured verti above a fixed, permanent platform, step or steps whose minimum width shall equal or excee operable width of the opening and shall be centered on such opening and which shall comply Sections R311.7.5.1 and R311.7.5.2. Glazing in windows complying with this exception shall n subject to the provisions of Section R308.4.6 or R308.4.7. - pdf_text
2 2. Constructing in accordance with ASCE 32; or - pdf_text
2 2. A visual inspection of the building envelope tightness and insulation shall be considered accep when the items listed in Table N1102.4.1.1 (Section R402.4.1.1), applicable to the meth construction, are field verified. Where required by the code official, an approved party indepe from the installer of the insulation shall inspect the air barrier and insulation. CHAPTER 13 – GENERAL MECHANICAL SYSTEM REQUIREMENTS (Amd) M1301.1 Scope. The provisions of this chapter shall govern the installation of mechanical sys not specifically covered in other chapters applicable to mechanical systems. Installations of mecha appliances, equipment and systems not addressed by this code shall comply with the applicable provi of the International Mechanical Code and requirements as noted in Section R101.4.1 for fuel gas. CHAPTER 14 – HEATING AND COOLING EQUIPMENT AND APPLIANCES (Amd) M1402.1 General. Oil-fired central furnaces shall conform to ANSI/UL 727. Electric furnaces conform to UL 1995 or UL/CSA 60335-2-40. (Amd) M1403.1 Heat pumps. Electric heat pumps shall be listed and labeled in accordance with UL or UL/CSA 60335-2-40. (Amd) M1412.1 Approval of equipment. Absorption systems shall be installed in accordance wit manufacturer’s instructions. Absorption equipment shall comply with UL 1995 or UL/CSA 60335-2- (Amd) M1413.1 General. Evaporative cooling equipment and appliances shall comply with UL 199 UL/CSA 60335-2-40 and shall be installed: - pdf_text
2 2. Intentionally confounds identification of the means of egress path. - pdf_text
2 2. Group R-3 and R-4 occupancies. Basements and sleeping rooms below the fourth story above grade plane shall have not fewer than emergency escape and rescue opening in accordance with this section. Where basements contain o more sleeping rooms, an emergency escape and rescue opening shall be required in each sleeping r but shall not be required in adjoining areas of the basement. Such openings shall open directly into a p way or to a yard or court that opens to a public way. Exceptions: - pdf_text
2 2. Protection of freestanding accessory structures with an area of 400 square feet (37 m2) or le other than light-frame construction, with an eave height of 10 feet (3048 mm) or less shall n required. - pdf_text
2 2. The number of Type B units shall be permitted to be reduced in accordance with Section R32 (Add) R320.4 General exceptions. Where permitted by Sections R320.2 and R320.3, the required nu of Type B units shall be permitted to be reduced in accordance with Sections R320.4.1 and R320.4.2. (Add) R320.4.1 Site impracticality. On a site with multiple buildings, the number of units require Sections R320.2 and R320.3 to be Type B units may be reduced to a percentage which is equal t percentage of the entire site having grades, prior to development, which are less than 10 percent, pro not less than 20 percent of the Type B units required by Sections R320.2 and R320.3 on the sit provided. - pdf_text
2 2. A Group M fire area is located more than three stories above grade plane. - pdf_text
2 2. In residential buildings designed to be occupied by one or two families. - pdf_text
2 2. ICC Standard for Residential Construction in High-Wind Regions (ICC 600). - pdf_text
2 2. In existing buildings four stories or less in height containing not more than four dwelling where dwelling units are added to an existing Group R use that does not involve a physical inc in the height or area of the building and where each dwelling unit has either: - pdf_text
2 2. Child washing and diaper changing facilities shall be permitted in lieu of bathtubs or show Group I-4 child care occupancies. (Add) 2902.1.2.1 Baby changing facilities. Where multiple single-user toilet rooms or bathing roo clustered at a single location, at least one room at each cluster shall contain baby changing facilitie shall be identified as containing such facilities. CHAPTER 30 - ELEVATORS AND CONVEYING SYSTEMS (Add) 3001.1.1 Equipment regulated by regulation. All elevators, dumbwaiters, material lifts, ve and inclined platform lifts, inclined stairway chairlifts, limited-use/limited-application elevators, escalators, including existing systems, shall comply with regulations adopted by the Commission Administrative Services pursuant to chapter 538 of the Connecticut General Statutes. Where the provi of this chapter conflict with the regulations adopted under chapter 538, the requirements of the regula shall prevail. (Del) 3001.2 Emergency elevator communication systems for the deaf, hard of hearing and spee impaired. Delete section in its entirety. CHAPTER 31 - SPECIAL CONSTRUCTION - pdf_text
2 2. The minimum headroom in all parts of existing stairways serving existing unfinished atti existing unfinished basements being converted to habitable space or replacement stairs wher pitch or slope cannot be reduced because of existing construction shall be 6 feet, 4 inches ( mm), measured in accordance with Section R311.7.2. (Amd) R311.7.5.1 Risers. The riser height shall be not more than 8¼ inches (209.5 mm). The riser be measured vertically between leading edges of adjacent treads. The greatest riser height within any f of stairs shall not exceed the smallest by more than ⅜ inch (9.5 mm). Risers shall be vertical or sl from the underside of the nosing of the tread above at an angle not more than 30 degrees (0.51 rad) the vertical. Open risers are permitted provided that the opening between treads does not permit the pas of a 4-inch-diameter (102 mm) sphere. Exceptions: - pdf_text
2 2. Group I-1, I-2, I-4 and R occupancies where any of the conditions in Sections 915.1.2 thr - pdf_text
2 2. Those that do not contain conditioned space. - pdf_text
2 2. Inspect Framing and Details a. Framing layout, member sizes and bearing lengths b. Blocking and bridging c. Holes and notchesa X X X - pdf_text
2 2. In areas where the basic design wind speed is 140 mph (63 m/s) or greater. CHAPTER 3 – USE AND OCCUPANCY CLASSIFICATION (Amd) 305.2 Group E, day care facilities. This group includes buildings and structures, or port thereof, occupied by more than six children 3 years of age or older who receive educational, supervi or personal care services for fewer than 24 hours per day. (Amd) 305.2.2 Six or fewer children. A facility having six or fewer children receiving such day care be classified as part of the primary occupancy. (Amd) 305.2.3 Family child care home. A family child care home, as described in subsection (a)( - pdf_text
2 2,500 square feet (232 m2) and are used for the sale, storage or handling of combustible goo merchandise. (Amd) 903.2.8 Group R. An automatic sprinkler system installed in accordance with Section 903.3 be provided throughout all newly constructed buildings with a Group R fire area or in existing buil that have a Group R fire area newly introduced by change of occupancy, occupancy group designati by an addition. Exceptions: - pdf_text
2 2. A slope exceeding 10 percent between the minimum required floor elevation at the pri entrance and the closest vehicular and pedestrian arrival points. (Add) R320.5 Accessible route. At least one accessible route shall connect accessible building or fa entrances with the primary entrance of each Type B unit within the building or complex and with t exterior and interior facilities that serve the units. Exception: If the slope of the finished ground level between accessible facilities and buildings exc - pdf_text
2 2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures, and the remova reinstallation of water closets, provided such repairs do not involve or require the replaceme rearrangement of valves, pipes or fixtures. (Del) 105.2.2 Public service agencies. Delete Section 105.2.2 and replace with Section 105.2.3. (Add) 105.2.2 Repairs. Application or notice to the building official is not required for ordinary repai structures, replacement of lamps or the connection of approved portable electrical equipment to appr permanently installed receptacles. Such repairs shall not include the cutting away of any wall, partiti portion thereof, the removal or cutting of any structural beam or load-bearing support, or the remov change of any required means of egress, or rearrangement of parts of a structure affecting the e requirements; nor shall ordinary repairs include addition to, alteration of, replacement or relocation of standpipe, water supply, sewer drainage, drain leader, gas, soil, waste, vent or similar piping, electric w or mechanical or other work affecting public health or general safety. (Add) 105.2.3 Public service agencies. Pursuant to section 29-282 of the Connecticut General Statut permit shall not be required for the installation, alteration or repair of generation, transmission, distribu metering or other related equipment that is under the ownership and control of public service agencie established right. - pdf_text
2 2. Grease duct systems or exhaust equipment listed for clearances less than those required in Se - pdf_text
2 2. The fire area has an occupant load of 300 or more or where the occupant load exceeds 100 or in the following assembly occupancies: a. Dance halls b. Discotheques c. Nightclubs d. Assembly occupancies with festival seating - pdf_text
2 2. Stories, mezzanines or occupied roofs that do not contain accessible elements or other spac determined by Section 1108 or 1109 are not required to be served by an accessible route fro accessible level. - pdf_text
2 2. The material, in the form in which it is used, exhibits a potential heat value not exceeding Btu/lb (8141 kJ/kg), when tested in accordance with NFPA 259, Standard Test Method for Pote Heat of Building Materials. - pdf_text
2 2. A care facility for three or fewer persons receiving custodial care within a dwelling unit sha permitted to be constructed in accordance with this code. - pdf_text
2 2. The length or width of the occupancy exceeds 300 feet (91 m). Exceptions: - pdf_text
2 2. Buildings protected throughout by an approved, supervised automatic fire sprinkler in accord with Section 903.3.1.1. (Add) 429.2.1 Area of smoke compartments. The area of any smoke compartment required by Se - pdf_text
2 2. 60 feet in height; - pdf_text
2 2. Declare ERI on title page and building plans. - pdf_text
2 2. Reinstallation of attachment plug receptacles but not the outlets therefor. - pdf_text
2 2. Decks, patios and walkways that have a single change in elevation where the landing depth on side of the change in elevation is greater than what is required for a landing do not require handr - pdf_text
2 2. The depth in the direction of travel of landings of existing stairs serving existing unfinished or basements being converted to habitable space or replacement stairs within existing dwel shall be at least equal to the stair width but not less than 32 inches (813 mm) where Se R311.7.1, Exception 2 is utilized for a reduced stair width. (Add) R312.1.1.1 Retaining wall guards. Retaining walls with a difference in height between the fini grade at the top of the wall and the finished grade at the bottom of the wall that is greater than 4 feet ( mm) shall be provided with guards complying with Section R312 when there is a walking surface, par lot or driveway on the high side located closer than 2 feet (610 mm) to the nearest side of the retai wall. For the purposes of this section, grass, planting beds or landscaped areas are not a walking surfa - pdf_text
2 2. Where the owner occupies the facility or an adjacent property as his or her primary place of residence, - pdf_text
2 2. A visual inspection of the building envelope tightness and insulation shall be considered accep when the items listed in Table R402.4.1.1, applicable to the method of construction, are verified. Where required by the code official, an approved party independent from the install the insulation shall inspect the air barrier and insulation. - pdf_text
2 2. Fire separation assemblies shall not be required when the kitchen is equipped with a l residential range top extinguisher unit or an approved commercial kitchen hood with a li approved automatic fire suppression system. - pdf_text
2 2. For occupancies in Group R-3, and within individual dwelling units in occupancies in Group guards on the open sides of stairs shall have a height not less than 34 inches (864 mm) meas vertically from a line connecting the leading edges of the treads. - pdf_text
2 2. Where all appliances in the house are of sealed combustion, power-vent, unvented, or electri exhaust hood system shall be permitted to exhaust up to 600 cubic feet per minute (0.28 without providing makeup air. Exhaust hood systems capable of exhausting in excess of 600 feet per minute (0.28 m3/s) shall be provided with a makeup air at a rate approximately equal t difference between the exhaust air rate and 600 feet per minute. Such makeup air systems sh equipped with a means of closure. (Add) 505.4.1 Location. Kitchen exhaust makeup air shall be discharged into the same room in whic exhaust system is located or into rooms or duct systems that communicate through one or more perm openings with the room in which such exhaust system is located. Such permanent openings shall have cross-sectional area not less than the required area of the makeup air supply openings. - pdf_text
2 2. Log homes designed in accordance with ICC 400. (Add) N1103.3.1.1 (R403.2.1.1) Duct insulation values. Minimum duct insulation values stated in Se N1103.2.1 shall be installed R-values. (Amd) N1103.6 (R403.6) Mechanical ventilation. The buildings complying with Section R402.4.1 be provided with ventilation that complies with the requirements of Section M1505.4 of the Internati Residential Code or International Mechanical Code, as applicable, or with other approved mea ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close whe ventilation system is not operating. (Amd) N1106.2 (R406.2) ERI compliance. Compliance based on the Energy Rating Index (ERI) req that the rated design meet all of the following: - pdf_text
2 2. Buildings and structures in Risk Category II in accordance with Table 1604.5, which are in exposure category B or C in accordance with Section 1609.4.3, are in Seismic Design Catego or B, and are not more than three stories high. - pdf_text
2 2. Aisle accessways in Group A. - pdf_text
2 2. On level platforms in accordance with Section M1305.1.3.1. - pdf_text
2 2. The registered design professional responsible for the design of the roof structure certifies th roof structure is designed to support all loads, including any additional loads resultant t reduced slope. CHAPTER 16 – STRUCTURAL DESIGN (Amd) 1602.1 Notations. Amend following item only: V = Basic design wind speed, miles per hour (mph) (km/hr), determined from Appendix P. (Amd) 1603.1.3 Roof snow load data. The ground snow load, Pg, shall be indicated. In areas wher ground snow load, Pg, exceeds 10 pounds per square foot (psf) (0.479 kN/m2), the following addit information shall also be provided, regardless of whether snow loads govern the design of the roof: - pdf_text
2 2. Facilities with open-air assembly seating shall be permitted to use the capacity factors in Se - pdf_text
2 2. Seasonally occupied buildings. (Add) 118.4 Removal of hazardous materials. Persons owning, or in charge or control of, a va building or portion thereof, shall remove all accumulations of hazardous materials as defined by this c CHAPTER 2 – DEFINITIONS (Amd) 201.3 Terms defined in other codes. Where terms are not defined in this code and are defin other codes adopted as portions of the 2022 Connecticut State Building Code, such terms shall hav meanings ascribed to them as in those adopted codes. (Add) 202.1 Definitions. Add or amend the following definitions: (Add) ACCESSORY STRUCTURE. A structure that is accessory to and incidental to that of a Grou - pdf_text
2 2. Fire service access elevator machine rooms and machinery spaces. - pdf_text
2 2. Electrical equipment used solely for radio and television transmissions, but a permit is require equipment and wiring for power supply and for the installation of towers and antennas. - pdf_text
2 2. The registered design professional responsible for the design of the roof structure certifies th roof structure is designed to support all loads, including any additional loads resultant t reduced slope. (Amd) 1507.13.1 Slope. Thermoplastic single-ply membrane roofs shall have a design slope of a mini of one-fourth unit vertical in 12 units horizontal (2-percent slope) for drainage. Exception: A minimum design slope of one-eighth unit vertical in 12 units horizontal sha permitted when the following two conditions are met: - pdf_text
2 2. Accessible passenger loading zones. - pdf_text
2 2. Alterations to the exterior surfaces of existing buildings including, but not limited to, re-roo re-siding, window replacement and the construction of decks without roofs, are exempt fro requirements of this section. - pdf_text
2 2. On stairways and stepped aisles, from the line connecting the leading edges of the tread nosin - pdf_text
2 2. Spiral stairways in accordance with Section 1011.10. - pdf_text
2 2. Electrical work shall meet the requirements of NFPA 70, National Electrical Code. - pdf_text
2 2. For buildings complying under with Section R401.2.2, the building shall meet one o following: - pdf_text
2 2. The new or existing retail store or retail sales facility complies with the provisions of NFPA for new stores and facilities as herein amended. (Add) 307.5.2 Storage rooms. The provisions of NFPA 1124, 2006 edition, are amended for u Connecticut as follows: (Amd) NFPA 1124, 7.3.7 Storage rooms. Storage rooms containing consumer fireworks, regar of size, in a new or existing permanent store shall be protected with an automatic sprinkler sy installed in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, or separ from the retail sales area by a fire barrier having a fire-resistance rating of not less than 1 hour. quantity of fireworks permitted in storage shall not exceed 3,600 cubic feet, including packaging. storage shall be segregated into areas of 1,200 cubic feet or less, separated by a minimum of 4 fe clear space. (Amd) NFPA 1124, 7.5.3 Storage rooms. Storage rooms containing consumer fireworks, regar of size, in a new or existing permanent store shall be protected with an automatic sprinkler sy installed in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, or separ from the retail sales area by a fire barrier having a fire-resistance rating of not less than 1 hour. quantity of fireworks permitted in storage shall not exceed 3,600 cubic feet, including packaging. storage shall be segregated into areas of 1,200 cubic feet or less, separated by a minimum of 4 fe clear space. - pdf_text
2 2. Opening of a circuit breaker or fuse. - pdf_text
2 2. A certificate of occupancy is not required for work exempt from permit requirements under Se - pdf_text
2 2. In dwelling units and sleeping units located more than one story above or below a private gar - pdf_text
2 (cont. 2) (Add) 915.7 Alterations and additions. When alterations or additions requiring a permit occ buildings with Group R-3 and R-4 occupancies and to Group R-1 bed and breakfast establishment when one or more sleeping rooms are added or created in such occupancies, the entire occupancy sha provided with carbon monoxide detectors located as required for new construction. The carbon mon detectors shall have a power source in accordance with Section 915.4.1. When alterations or additions requiring a permit occur to buildings with Group I-1, I-2, I-4, R-1 other bed and breakfast establishments, R-2 and E, or when one or more sleeping rooms are added or creat such occupancies, only the work area shall be provided with carbon monoxide detectors located as req - pdf_text
2 (cont. 2) (Amd) R402.4.1.2 Testing. The building or dwelling unit shall be tested for air leakage. The maximu leakage rate for any building or dwelling unit under any compliance path shall not exceed 5.0 air cha per hour or 0.28 cubic feet per minute (CFM) per square foot [0.0079 m3/(s × m2)] of dwelling enclosure area. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380, ASTM E7 ASTM E1827 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Where required by the code off testing shall be conducted by an approved third party. A written report of the results of the test sha signed by the party conducting the test and provided to the code official. Testing shall be performed a time after creation of all penetrations of the building thermal envelope have been sealed. Exception: For heated, attached private garages and heated, detached private garages accesso one- and two-family dwellings and townhouses not more than three stories above grade pla height, building envelope tightness and insulation installation shall be considered acceptable the items in Table R402.4.1.1, applicable to the method of construction, are field verified. W required by the code official, an approved third party independent from the installer shall in both air barrier and insulation installation criteria. Heated, attached private garage space and he - pdf_text
2 (cont. 2) (Amd) 3102.1 General. The provisions of this section shall apply to air-supported, air-inflated, memb covered-cable, membrane-covered-frame structures and tensile membrane structures, collectively k as membrane structures, erected for a period of 180 days or longer. Those erected for a shorter time comply with Section 3103.5. Membrane structures covering water storage facilities, water clarifiers, treatment plants, sewage treatment plants, greenhouses and similar facilities not used for human occup are required to meet only the requirements of Sections 3102.3.1 and 3102.7. Membrane structures er on a building, balcony, deck or other structure shall comply with this section. - pdf_text
2 (cont. 2) (Add) 1103.2.15 Statutory requirements. Pursuant to section 29-274 of the Connecticut General Stat the following are additional exceptions to requirements for accessibility: - pdf_text
2 (cont. 2) (Add) 505.4.2 Makeup air dampers. Where makeup air is required by Section 505.4, makeup air da shall comply with this section. Each damper shall be a gravity damper or an electrically operated da that automatically opens when the exhaust system operates. Dampers shall be located to allow acces inspection, service, repair and replacement without removing permanent construction or any other not connected to the damper being inspected, serviced, repaired or replaced. Gravity or barometric da shall not be used in passive makeup air systems except where the dampers are rated to provide the d makeup airflow at a pressure differential of 0.01 in. w.c. (3 Pa) or less. - pdf_text
2 (cont. 2) (Add) 105.2.4 State agency exemptions. Pursuant to section 29-252a of the Connecticut General Stat a state agency shall not be required to obtain a building permit from a local building official. A state ag shall obtain a building permit for construction work, as described in section 29-252a of the Connec General Statutes, from the State Building Inspector. Exception: Pursuant to sections 29-401 to 29-415, inclusive, of the Connecticut General Statutes state agencies shall obtain demolition permits from the local building official. (Add) 105.2.5 Federal agency exemptions. A federal agency performing construction on federally o land or on leased land totally under the control of the federal government shall not be required to obt building permit or a demolition permit from the local building official. (Amd) 105.3 Application for Permit. To obtain a permit, the applicant shall first file an applic therefor in writing on a form furnished by the department of building safety for that purpose. application shall: - pdf_text
2 (cont. 2) (Add) R105.3.1.2 Zoning approval. Pursuant to subsection (f) of section 8-3 of the Connecticut Ge Statutes, no building permit shall be issued, in whole or in part, for a building, use or structure subje the zoning regulations of a municipality without certification in writing by the official charged wit enforcement of such regulations that such building, use or structure is in conformity with such regulat or is a valid nonconforming use under such regulations. (Add) R105.3.1.3 Historic certificate of appropriateness. Pursuant to subsection (b) of section 7- of the Connecticut General Statutes, no building permit for erection of a building or structure o alteration of an exterior architectural feature within the boundaries of an historic property an demolition permit for demolition or removal of a building or structure within the boundaries of an his property shall be issued by a municipality or any department, agency or official thereof until a certif of appropriateness has been issued. - pdf_text
2 (cont. 2) (Amd) 308.2.3 Four to 16 persons receiving custodial care. A facility housing not fewer than four not more than 16 persons receiving custodial care shall be classified as R-4. - pdf_text
2 (cont. 2) (Amd) R315.2.2 Alterations, repairs and additions. Where alterations, repairs or additions requiri permit occur, or where one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be equipped with carbon monoxide alarms located as required for new dwellings. Exceptions: - pdf_text
2 (cont. 2) (Amd) R305.1 Minimum height. Habitable space, hallways and portions of basements containing t spaces shall have a ceiling height of not less than 7 feet (2134 mm). Bathrooms, toilet rooms and lau rooms shall have a ceiling height of not less than 6 feet 8 inches (2032 mm). Existing basements b converted to habitable space shall have a ceiling height of not less than 6 feet 8 inches (2032 mm). - pdf_text
2 (cont. 3) (Amd) 506.3.2.5 Grease duct test. Prior to the use or concealment of any portion of a grease duct sys a leakage test shall be performed. Ducts shall be considered to be concealed where installed in shaf covered by coatings or wraps that prevent the ductwork from being visually inspected on all sides. Th shall be performed for the entire duct system, including the hood-to-duct connection. All connecti seams and welds shall be visible during the test. The ductwork shall be permitted to be tested in sect provided that every joint is tested. For listed factory-built grease ducts, this test shall be limited to joints assembled in the field and shall exclude factory welds. The permit holder shall be responsib provide the necessary equipment and perform the grease duct leakage test. The leakage test shall consi one of the following tests, or an approved equivalent test: (Add) 506.3.2.5.1 Positive pressure smoke test. The positive pressure smoke test shall be performe sealing the entire duct system from the hood exhaust opening(s) to the duct termination. Visible s shall be introduced to the duct system. The sealed duct shall then be pressurized to a minimum pressu - pdf_text
2 (cont. 3) (Add) R105.3.1.4 Notice to Public Water Authority. Pursuant to section 19a-37d of the Connec General Statutes, when a permit application is filed with the building official of any municip concerning any project that includes a change of use or installation of fixtures or facilities in a building may affect the performance of, or require the installation of, a reduced pressure principle back preventer, a double check valve assembly or a pressure vacuum breaker, the building official shall pro written notice of the application to the water company serving the building not later than 7 days afte date the application is filed. Upon receipt of such written notice, the water company shall cause t performed an evaluation of cross-connection protection by a person who has met the requirem prescribed in the Regulations of Connecticut State Agencies and such water company shall notif building official regarding its determination. The building official shall not issue a permit or certifica occupancy until any cross-connection issue has been corrected. - pdf_text
2 (cont. 3) (Add) 3102.3.1.2 Flame propagation performance testing and certification. Before a permit is gra the owner or the owner’s agent shall file with the fire code official a certificate provided by the pr manufacturer to verify that the materials have been tested and certified by an approved testing labora The certificate shall indicate that the floor coverings, tents, membrane structures and their appurtena which include sidewalls, drops and tarpaulins, are composed of materials meeting the flame propag performance of Test Method 2 of NFPA 701. Additionally, it shall indicate that the bunting and combus decorative materials and effects are composed of material meeting the flame propagation perform criteria of Test Method 1 or Test Method 2 of NFPA 701, as applicable. Alternatively, the materials be treated with a flame retardant in an approved manner and meet the flame propagation perform criteria of the applicable test method of NFPA 701. The certificate shall indicate compliance with the te requirements of NFPA 701, Chapter 16. The flame propagation performance criteria shall be effectiv the period specified by the permit. (Add) 3102.3.1.3 Label. Membrane structures or tents shall have a permanently affixed label be the following information: - pdf_text
2.1 2.1. Individual tents having a maximum size of 700 square feet (65 m2). - pdf_text
2.1 2.1. In an approved location between the fuel-burning appliance or fuel-burning fireplace an dwelling unit or sleeping unit. - pdf_text
2.1 2.1 One of the additional efficiency package options in Section R408.2 sha installed without including such measures in the proposed design under Se R405; or - pdf_text
2.1 2.1. The aggregate floor area of the membrane structure or tent shall not exceed 10,000 s feet (929 m2). - pdf_text
2.1 2.1. An exit door directly to the exterior at a level of exit discharge, - pdf_text
2.2 2.2. On the ceiling of the room containing the fuel-burning appliance or fuel-burning firepl (Amd) 915.1.5 Private garages. Carbon monoxide detection shall be provided in dwelling units sleeping units in buildings with attached private garages. Exceptions: - pdf_text
2.2 2.2. The aggregate floor area of the building and membrane structure or tent shall not excee allowable floor area including increases as indicated in this code. - pdf_text
2.2 2.2 The proposed design of the building under Section R405.3 shall have an a energy cost that is less than or equal to 95 percent of the annual energy cost o standard reference design. The option selected for compliance shall be identified in the certificate required by Section R4 (Amd) R402.1 General (Prescriptive). The building thermal envelope shall meet the requiremen Sections R402.1.1 through R402.1.5. Exceptions: - pdf_text
2.2 2.2. Multiple tents placed side by side without a fire break clearance of 12 feet (3658 mm), an aggregate area not exceeding 700 square feet (65 m2) total. - pdf_text
2.2 2.2. Direct access to an exterior stair serving a maximum of two dwelling units on the same s or - pdf_text
2.2 2.2. Multiple tents placed side by side without a fire break clearance of 12 feet (3658 with an aggregate area not exceeding 700 square feet (65 m2) total. - pdf_text
2.3 2.3. A minimum clearance of 12 feet (3658 mm) to all other structures and tents. - pdf_text
2.3 2.3. Direct access to an interior stair serving only that dwelling unit and separated from all portions of the building with 1-hour fire-resistance-rated fire barriers. - pdf_text
2.3 2.3. Required means of egress are provided for both the building and membrane structure or including travel distances. (Add) 3103.5.4.1 Location of structures in excess of 15,000 square feet in area. Membrane struc having an area of 15,000 square feet (1394 m2) or more shall be located not less than 50 feet (15 240 from any other tent or structure as measured from the sidewall of the tent or membrane structure u joined together by a corridor. (Add) 3103.5.4.2 Membrane structures on buildings. Membrane structures that are erected on build balconies, decks or other structures shall be regulated as permanent membrane structures in accord with Section 3102. (Add) 3103.5.4.3 Connecting corridors. Tents or membrane structures are allowed to be joined tog by means of corridors. Exit doors shall be provided at each end of such corridor. On each side of corridor and approximately opposite each other, there shall be provided openings not less than 12 (3658 mm) wide. (Add) 3103.5.4.4 Fire break. An unobstructed fire break passageway or fire road not less than 12 (3658 mm) wide and free from guy ropes or other obstructions shall be maintained on all sides of all and membrane structures unless otherwise approved by the building official. - pdf_text
2.3 (cont. 2) (Add) 3103.5.5 Structural stability and anchorage required. Tents or membrane structures and appurtenances shall be designed and installed to withstand the elements of weather and prevent colla in accordance with the manufacturer’s instructions or this code. Documentation of structural stability be furnished to the building official. - pdf_text
2.67 2.67 PE pipe or tubing - pdf_text
2.67 2.67 (32 inches)c Cross-linked polyethylene/aluminum/cross-linked polyethylene (PEX- AL-PEX) pipe 1 inch and larger - pdf_text
2.67 2.67 PE-RT ≥ 11/4 inches - pdf_text
2.67 2.67 (32 inches) Polypropylene (PP) pipe or tubing, 11/4 inches and larger - pdf_text
2.67 2.67b Cross-linked polyethylene/aluminum/crosslinked polyethylene (PEX-AL- PEX) pipe 1 inch and larger - pdf_text
2.67 2.67 PEX tubing ≥ 11/4 inches - pdf_text
2.67 2.67 (32 inches) Polyethylene of raised temperature (PE-RT) pipe, 11/4 inches and larger - pdf_text
2.67 2.67 (32 inches) Polyethylene of raised temperature (PE-RT) pipe, 1 inch and smaller - pdf_text
2.67 2.67 PE-RT ≤ 1 inch - pdf_text
2.67 2.67 (32 inches) Cross-linked polyethylene (PEX) pipe, 11/4 inches and larger - pdf_text
2.67 2.67 (32 inches)c Polypropylene (PP) pipe or tubing (11/4 inches and larger) - pdf_text
2.67 2.67 (32 inches)c Cross-linked polyethylene/aluminum/cross-linked polyethylene (PEX-AL- PEX) pipe 1 inch and larger - pdf_text
2.67 2.67b PP > 1 inches - pdf_text
2017 2017 ICC/ANSI A117.1 Accessible and Usable Buildings and Facilities - pdf_text
2020 2020 NFPA 70, National Electrical Code, of the National Fire Protection Association Inc. - pdf_text
2021 2021 International Existing Building Code - pdf_text
2021 2021 International Residential Code Copies of the International Codes may be obtained from the International Code Council, Inc., 4051 Flossmoor Road, Country Club Hills, IL 60478-5795 (website: www.iccsafe.org). Copies of the 2020 NFPA 70, National Electrical Code, may be obtained from the National Fire Prote Association Inc., 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02169-7471 (website: www.nfpa. Copies of the 2022 Connecticut State Building Code document may be downloaded from the we www.portal.ct.gov/DAS. The requirements of the 2022 Connecticut State Building Code shall apply to all work for which a pe application was made on or after the date of adoption. As used in this document, these annotations have the following meaning: Add: A section or subsection preceded by (Add) indicates the addition of this section or subsecti the adopted referenced standard. Amd: A section or subsection preceded by (Amd) indicates the substitution of this section or subse in the adopted referenced standard. Del: A section or subsection preceded by (Del) indicates the deletion of this section or subsection the adopted referenced standard. - pdf_text
2021 2021 International Building Code portion of the 2022 Connecticut State Building Code. (Add) 101.1.1 Statutes. Pursuant to sections 29-252a and 29-253 of the Connecticut General Stat respectively, this code shall be the building code for all towns, cities and boroughs and all state agenc (Amd) 101.2 Scope. The provisions of this code shall apply to the construction, alteration, move enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal demolition of every building or structure or any appurtenances connected or attached to such buildin structures. Exception: Detached one- and two-family dwellings and multiple single-family dwel (townhouses) not more than three stories above grade plane in height with a separate means of eg and their accessory structures not more than three stories above grade plane in height, shall co with the 2021 International Residential Code portion of the 2022 Connecticut State Building Cod (Amd) 101.2.1 Appendices. The provisions of Appendices C, H, I and P shall be incorporated int requirements of this code. (Amd) 101.4.1 Gas. The International Fuel Gas Code is not adopted by the state of Connecticut. references to the International Fuel Gas Code within the body of this code shall be considered refere to requirements of NFPA 2, Hydrogen Technologies Code; NFPA 54, National Fuel Gas Code; and N - pdf_text
2021 2021 International Building Code portion of the 2022 Connecticut State Building Code – Stop Work O (Del) SECTION C110 – BOARD OF APPEALS. Delete in its entirety and refer to Section 113 o - pdf_text
2021 2021 International Building Code portion of the 2022 Connecticut State Building Code – Stop Work O (Del) SECTION R110 – BOARD OF APPEALS. Delete in its entirety and refer to Section 113 o - pdf_text
2021 2021 International Building Code portion or Section R110.6 of the 2021 International Residential portion, as applicable, of the 2022 Connecticut State Building Code. (Del) SECTION 108 FEES. Delete in its entirety and refer to Section 109 of the 2021 Internati Building Code portion or Section R107 of the 2021 International Residential Code portion, as applic of the 2022 Connecticut State Building Code – Fees. - pdf_text
2021 2021 International Swimming Pool and Spa Code - pdf_text
2021 2021 International Plumbing Code - pdf_text
2021 2021 International Building Code portion or Section R114 of the 2021 International Residential portion, as applicable, of the 2022 Connecticut State Building Code – Violations. CHAPTER 2 – DEFINITIONS (Amd) 201.3 Terms defined in other codes. Where terms are not defined in this code and are defin other codes adopted as portions of the State Building Code, such terms shall have the meanings ascrib them in those codes. (Add) 202.1 Definitions. Amend or add the following definitions: (Add) BUILDING OFFICIAL. The officer or other designated authority charged with the administr and enforcement of this code, or a duly authorized representative. Also known as the local building off or the code official. (Amd) CODE OFFICIAL. See Building official. (Amd) DESIGN PROFESSIONAL. An individual who is registered or licensed by the Departme Consumer Protection pursuant to chapters 390, 391, 396 or 396a of the Connecticut General Statut practice the individual’s respective design profession and acting within the scope of his or her licens practice discipline. - pdf_text
2021 2021 International Mechanical Code - pdf_text
2021 2021 International Building Code - pdf_text
2021 2021 International Building Code portion of the 2022 Connecticut State Building Code – Means of Ap CHAPTER 2 [CE] – DEFINITIONS (Amd) C201.3 Terms defined in other codes. Where terms are not defined in this code and are defin other codes adopted as portions of the 2022 Connecticut State Building Code, such terms shall hav meanings ascribed to them as in those codes. (Add) C202.1 Definitions. Add or amend the following definitions: (Add) BUILDING OFFICIAL. The officer or other designated authority charged with the administr and enforcement of this code, or a duly authorized representative. Also known as the local building off or code official. (Amd) CODE OFFICIAL. See building official. CHAPTER 4 [CE] – COMMERCIAL ENERGY EFFICIENCY (Amd) C402.1.1 Low energy buildings. The following buildings, or portions thereof, separated fro remainder of the building by building thermal envelope assemblies complying with this code sha exempt from the building thermal envelope provisions of Section C402: - pdf_text
2021 2021 International Energy Conservation Code - pdf_text
2021 2021 International Building Code portion of the 2022 Connecticut State Building Code – Means of Ap CHAPTER 2 [RE] – DEFINITIONS (Amd) R201.3 Terms defined in other codes. Where terms are not defined in this code and are defin other codes adopted as portions of the 2022 Connecticut State Building Code, such terms shall hav meanings ascribed to them as in those codes. (Add) R202.1 Definitions. Add or amend the following definitions: (Add) Attached Dwelling Unit. A dwelling unit sharing demising walls, floors, ceilings or com corridors with another dwelling unit or occupied space. (Add) BUILDING OFFICIAL. The officer or other designated authority charged with the administr and enforcement of this code, or a duly authorized representative. Also known as the local building off or code official. (Amd) CODE OFFICIAL. See building official. - pdf_text
2021 (cont. 2) (Amd) PUBLIC POOL. An artificial basin constructed of concrete, steel, fiberglass or other imper material and equipped with a controlled water supply that is intended for recreational bathing, swim diving or therapeutic purposes and includes, but is not limited to, any related equipment, structure, ar enclosure intended for the use of any person using or staffing such pool. “Public pool” does not inclu artificial basin provided with a controlled water supply that is intended for use as a residential pool, e when such basin is used for commercial or business purposes at such residence. The followin subclasses of public pools: (A) Public swimming pool, which is a pool used or intended to be used for recreational bat swimming or water recreation activities. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Energy Conservation Code Page - (Amd) R103.5 Retention of construction documents. The building official shall retain one set of appr construction documents for a period as set forth in the records/disposition schedule adopted pursua chapter 188 of the Connecticut General Statutes. (Del) SECTION R104 – FEES. Delete in its entirety and refer to Section 109 of the 2021 Internati Building Code portion of the 2022 Connecticut State Building Code – Fees. (Add) R105.7 Posting of required inspections. A schedule of required inspections shall be compile the code official. The schedule shall be posted in the building department for public view. (Add) R105.8 Notification of inspection and testing results. Notification as to passage or failure, in w or in part, of any required inspection or test shall be made in writing by the building official or his authorized representative and shall be left at the job site or delivered to the permit holder. It shall b duty of the permit holder to ascertain the results of required inspections. (Del) SECTION R106 - NOTICE OF APPROVAL. Delete in its entirety and refer to Section 111 the 2021 International Building Code portion of the 2022 Connecticut State Building Code. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Pag Building: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Plumbing Code Page local building inspector shall provide written notice of the application to the water company serving the building not later than seven days after the date the application is filed. Upon rece of such written notice, the water company shall cause to be performed an evaluation of cross- connection protection by a person who has met the requirements prescribed in the regulations Connecticut state agencies and such water company shall notify the local building inspector regarding its determination. The local building inspector shall not issue a permit or certificate occupancy until any cross-connection issue has been corrected. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 1809.5 Frost protection. Except where otherwise protected from frost, foundations and permanent supports of buildings and structures shall be protected from frost by one or more of the follo methods: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 308.2.4 Three or fewer persons receiving custodial care. A facility with three or fewer per receiving custodial care shall be classified as Group R-3 or shall comply with the International Reside Code. (Amd) 308.3 Group I-2. Institutional Group I-2 occupancy shall include buildings and structures use medical care on a 24-hour basis for more than three persons who are incapable of self-preservation. group shall include, but not be limited to, the following: Foster care facilities Detoxification facilities Hospitals Nursing homes Psychiatric hospitals (Amd) 308.3.2 Three or fewer persons receiving care. A facility with three or fewer persons recei medical care shall be classified as Group R-3 or shall comply with the International Residential C provided an automatic sprinkler system is installed in accordance with Section 903.3.1.3 or Section P of the International Residential Code. (Add) 308.3.3 Alternative compliance for small I-2 homes. See Section 407.14 for alternative compli provisions for Group I-2 homes serving four to six persons who are incapable of self-preservation. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/2022 Amendments to the 2021 International Building Code Page - 63 (Add) APPENDIX P MUNICIPALITY – SPECIFIC STRUCTURAL DESIGN PARAMETERS Municipality Basic Design Wind Speeds, V (mph) Allowable Stress Design Wind Speeds, Vasd (mph) Ground Snow Load, pg (psf) MCE Ground Accelerations Wind-Borne Debris Region1 Hurricane- Prone Region Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV SS (g) S1 (g) Risk Cat. III Occup. I-2 Risk Cat. IV Andover - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Plumbing Code Page (Amd) Table 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES. Re reference to footnote f. from row for Assembly, Stadiums, amusement parks, bleachers and grandst for outdoor sporting events and activities. (Del) Footnote f., Table 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES Delete footnote. (Add) 403.1.2.1 Baby changing facilities. Where multiple single-user toilet rooms or bathing room clustered at a single location, at least one room at each cluster shall contain baby changing facilitie shall be identified as containing such facilities. (Del) 403.2.1 Family or assisted-use toilet facilities serving as separate facilities. Delete without substitution. (Amd) 410.4 Substitution. Where restaurants provide drinking water in a container free of charge, drinking fountains shall not be required in those restaurants. In other occupancies permanently install bottle filling stations may be substituted for up to 2/3rds of the required drinking fountains. The bottl filling station shall be installed in accordance with ICC/ANSI A117.1. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to ICC/ANSI A117.1 - 2017 Page (Amd) 1104.3 Accessible Route. Accessible routes within Type B dwelling units shall comply with Se - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 1015.9 Retaining walls. Retaining walls where the difference in height between the finished at the top of the wall and the finished grade at the bottom of the wall is greater than 4 feet (1219 mm) be provided with guards complying with Sections 1015.3, 1015.4 and 1607.9 when a walking sur parking lot or driveway is located closer than 2 feet (610 mm) from the edge of the top of the retaining For the purpose of this section, grass, planting beds or landscaped areas shall not be considered a wal surface. (Amd) 1019.3 Occupancies other than Groups I-2 and I-3. In other than Group I-2 and I-3 occupan floor openings containing exit access stairways or ramps that do not comply with one of the condi listed in this section shall be enclosed with a shaft enclosure constructed in accordance with Section 7 - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page Exception: The number of accessible parking spaces for Type A units shall be permitted t calculated on the basis of the minimum number of Type A units being two percent of the number of dwelling units. - pdf_text
2022 2022 Connecticut State Building Code. (Amd) R108.2 Schedule of permit fees. Each municipality shall establish a schedule of fees for construction document review, building permit, certificate of approval and certificate of occupanc schedule of adopted fees shall be posted for public view. (Amd) R108.3 Building permit valuations. The applicant for a permit shall provide an estimated pe value at the time of application. Permit valuations shall include total value of work, including mate and labor, for which the permit is being issued, such as electrical, gas, mechanical, plumbing equip and permanent systems. If, in the opinion of the building official, the valuation is underestimated o application, the permit shall be denied, unless the applicant can show detailed estimates to meet approval of the building official. Final building permit valuation shall be set by the building official. (Del) R108.6 Work commencing before permit issuance. Delete without substitution. (Add) R109.1.4.1 Insulation inspection. Inspection of the building air tightness and insulation install shall be conducted in accordance with Section N1102.4.1. (Add) R109.1.5.2 Additional electrical inspections. Required electrical inspections shall inc installations of temporary services prior to activation and installation of underground piping and condu after trenches are excavated and bedded and before backfill is put in place. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 1015.3 Height. Required guards shall be not less than 42 inches (1067 mm) high, mea vertically as follows: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - CHAPTER 3 – BUILDING PLANNING (Amd) R301.1.3 Engineered design. Where a building of otherwise conventional construction con structural elements exceeding the limits of Section R301 or otherwise not conforming to this code, elements shall be designed in accordance with accepted engineering practice. The extent of such d need only demonstrate compliance of nonconventional elements with other applicable provisions and be compatible with the performance of the conventional framed system. Engineered design in accord with the International Building Code is permitted for buildings and structures, and parts thereof, incl in the scope of this code. Engineered design shall be certified by a registered design professional. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Swimming Pool and Spa Code Page - (B) Public wading pool, which is a pool principally used or intended to be used for wadin recreational bathing by small children. (C) Public spa, which is a pool used for recreational bathing in conjunction with a high-velocit system, a high-velocity water recirculation system, hot water, cold water, a mineral bath or combination thereof. (D) Public diving pool, which is a pool used solely for diving or the instruction and practici diving techniques. (E) Special purpose public pool, which is a pool used for a specialized purpose, including, bu limited to, a splash pad or spray park where the water is recirculated, water flume, pool use scuba diving instruction, therapeutic pool, hydrotherapy pool or a pool used in an aquatics pro for persons with disabilities. “Special purpose public pool” does not include a flotation v which shall not be subject to review by the Department of Public Health. For purposes of subparagraph, “flotation vessel” means a tank devoid of light and sound and containing salt in which a person floats for purposes, including, but not limited to, meditation, relaxation alternative medicine. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 406.3.2.1 Dwelling unit separation. The private garage shall be separated from the dwelling and its attic area by means of Type X gypsum board, not less than 5/8-inch (15.9 mm) in thickness, ap to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms abo not less than a 5/8-inch (15.9 mm) Type X gypsum board or equivalent and 5/8-inch (15.9 mm) Ty gypsum board applied to structures supporting the separation from habitable rooms above the garage. openings between a private garage and the dwelling unit shall be equipped with either solid wood doo solid or honeycomb core steel doors not less than 1⅜ inches (34.9 mm) in thickness, or doors in compli with Section 716.5.3 with a fire protection rating of not less than 20 minutes. Doors shall be self-cl and self-latching. (Add) 407.12 Laboratories. In addition to other requirements of this code, laboratories emplo quantities of flammable, combustible or hazardous materials that exceed exempt amounts shal protected in accordance with NFPA 99. (Add) 407.13 Medical gas systems. Medical gas systems shall comply with Chapter 12 of the Internati Plumbing Code and Section 5306 of the International Fire Code. - pdf_text
2022 2022 Connecticut Fire Safety Code and 2022 Connecticut Fire Prevention Code. CHAPTER 15 – REFERENCED STANDARDS (Del) APPENDIX B – RECOMMENDED PERMIT FEE SCHEDULE. Delete appendix. (Del) APPENDIX C – BOARD OF APPEALS. Delete appendix. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Energy Conservation Code Page - detached private garage space shall be thermally isolated from all other habitable, conditi spaces in accordance with Sections R402.2.12 and R402.3.5, as applicable. During testing: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - Municipality Ultimate Design Wind Speed, Vult (mph) Nominal Design Wind Speed, Vasd (mph) Ground Snow Load, pg (psf) Hurricane-Pro Region East Windsor - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Add) R110.8 Manufactured housing used as dwellings. Provisions for foundation systems and buil service equipment connections necessary to provide for the installation of new manufactured homes for existing manufactured homes to which additions, alterations or repairs are made are containe Appendix AE. (Add) R110.9 Concrete documentation. Pursuant to section 29-265c of the Connecticut General Stat prior to the issuance of a certificate of occupancy for a new residential or commercial building for wh concrete foundation was installed on or after October 1, 2016, the applicant shall provide the buil official with written documentation of the name of the individual or entity that supplied the concrete the name of the individual or entity that installed the concrete. Copies of such documentation sha maintained in the records of the office of the building official for not less than fifty years. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Add) M2201.7.2 Temporary removal from service. If a liquid fuel-burning appliance is converted alternate fuel, but the tank is kept in place so that it can be returned to service at some future date following requirements shall be met before the alternate fuel is used: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/2022 Amendments to the 2021 International Building Code Page - 68 Municipality Basic Design Wind Speeds, V (mph) Allowable Stress Design Wind Speeds, Vasd (mph) Ground Snow Load pg (psf) MCE Ground Accelerations Wind-Borne Debris Region1 Hurricane- Prone Region Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV SS (g) S1 (g) Risk Cat. III Occup. I-2 Risk Cat. IV Wethersfield - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 1608.1.3 Partial loading, unbalanced roof snow loads, drifts on lower roofs, roof projecti and parapets, and snow sliding. Calculations for partial loading, unbalanced roof snow loads, drifts lower roofs, roof projections and parapets, and snow sliding shall be in accordance with Sections 7.5, - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 1103.2.16 Mezzanines. Mezzanines having fewer than 3,000 square feet (278.7 m2) of gross f area, either singly or in the aggregate for multiple mezzanines on any floor, are not required to be acces and are not required to be located on an accessible route, provided that the goods and services availabl any mezzanine shall be available in accessible areas. (Amd) 1104.1 Site arrival points. At least one accessible route within the site shall be provided public transportation stops, accessible parking and accessible passenger loading zones, and public st or sidewalks to the accessible building entrance served. Where an accessible route must cross speed bu or vehicle wheel stops, there shall be a minimum clear passage width of not less than 32 inches (815 Exception: Other than in buildings or facilities containing or serving Type B units, an accessible r shall not be required between site arrival points and the building or facility entrance if the only m of access between them is a vehicular way not providing for pedestrian access. (Amd) 1104.4 Multilevel buildings and facilities. At least one accessible route shall connect accessible story, mezzanine and occupied roof in multilevel buildings and facilities. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page Documents for deferred submittals that relate to the primary structural support systems of buildin structures that exceed the threshold limit set forth in Section 107.7 of this code shall also be submitt the independent structural engineering consultant by the registered design professional in respon charge. Such deferred submittal items shall not be installed until the deferred submittal documents been reviewed and found to be in general conformance to the design of the building by the indepen structural engineering consultant and approved by the building official. (Amd) 107.5 Retention of construction documents. The building official shall retain one set of appr construction documents for a period as set forth in the records disposition schedule adopted pursua chapter 188 of the Connecticut General Statutes. Exception: Pursuant to subsection (e) of section 29-261 of the Connecticut General Statutes, receipt of a written request signed by the owner of plans and specifications on file for a single-fa dwelling or out-building, the building official shall immediately return the original plans specifications to the owner after a certificate of occupancy is issued with respect to the plans specifications. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2020 NFPA 70 National Electrical Code Page - c. Are on property owned or leased by the electric utility for the purpose of communicat metering, generation, control, transformation, transmission or distribution of electric energy; d. Are located by other written agreements either designated by or recognized by public ser commissions, utility commissions, or other regulatory agencies having jurisdiction for installations. These written agreements shall be limited to installations for the purpos communications, metering, generation, control, transformation, transmission, or distributio electric energy where legally established easements or rights-of-way cannot be obtained. T installations shall be limited to federal lands, Native American reservations through the Department of the Interior Bureau of Indian Affairs, military bases, lands controlled by authorities and state agencies and departments, and lands owned by railroads. (C) Special permission. The State Building Inspector may grant an exception for the installatio conductors and equipment that are not under the exclusive control of the electric utilities and are us connect the electric utility supply system to the service-entrance conductors of the premises ser provided such installations are outside a building or terminate immediately inside a building wall. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/2022 Amendments to the 2021 International Building Code Page - 65 Municipality Basic Design Wind Speeds, V (mph) Allowable Stress Design Wind Speeds, Vasd (mph) Ground Snow Load pg (psf) MCE Ground Accelerations Wind-Borne Debris Region1 Hurricane- Prone Region Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV SS (g) S1 (g) Risk Cat. III Occup. I-2 Risk Cat. IV Hampton - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 105.5 Expiration of permit. Every permit issued shall become invalid unless the work on the authorized by such permit is commenced within 180 days after its issuance, or if the work authorize such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. building official is authorized to grant, in writing, one or more extensions of time, for periods of not than 180 days each. The extensions shall be requested in writing and justifiable cause shall be demonstr Exception: The building official may specify an expiration date of not less than 30 days, nor more - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Pag Plumbing: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 1011.7.2 Outdoor conditions. Outdoor stairways and outdoor approaches to stairways sha designed so that water will not accumulate on walking surfaces. In other than occupancies in Group and occupancies in Group U that are accessory to an occupancy in Group R-3, treads, platforms landings that are part of exterior stairways shall be protected to prevent the accumulation of snow and (Amd) 1011.11 Handrails. Flights of stairways shall have handrails on each side and shall comply - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to ICC/ANSI A117.1 - 2017 Page AMENDMENTS TO ICC/ANSI A117.1 - 2017 (Amd) 106.2.8 Safety Code for Elevators and Escalators: ASME A17.1-2013 (American Societ Mechanical Engineers International, Two Park Avenue, New York, NY 10016-5990). (Amd) 106.2.9 Safety Standard for Platform Lifts and Stairway Chairlifts: ASME A18.1- (American Society of Mechanical Engineers International, Two Park Avenue, New York, NY 10 - pdf_text
2022 2022 Connecticut State Building Code, and the requirements as noted in Section R101.4.1 for fuel ga - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) N1110.3.1 (R502.3.1) Building envelope. New building envelope assemblies that are part o addition shall comply with Sections N1102.1, N1102.2, N1102.3.1 through N1102.3.5, and N1102.4. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page must be certified under the National Voluntary Laboratory Accreditation Program of the National Ins of Standards and Technology. (Add) BABY CHANGING FACILITIES. A table or other device suitable for changing the diaper child aged 3 or under. (Add) BULK MERCHANDISING RETAIL BUILDING. A building exceeding 12,000 square feet (1115 m2) in area in which the sales area includes the storage of combustible materials on pallets, in s piles or in racks in excess of 12 feet (3658 mm) in storage height. (Add) COMPLEX. For application of accessibility requirements, this term means any group of build located on a single parcel of land or on contiguous parcels of land or any building or group of build that are subdivided into separate occupancies and planned, financed, constructed or promoted by com management for the purpose of sale or lease of the entire complex or any subdivision thereof, except single-family detached dwelling. (Amd) EXISTING BUILDING. A building or structure, or portion thereof, erected in whole or in for which a legal building permit and a certificate of occupancy has been issued. Buildings or structur portions thereof erected prior to October 1, 1970 shall be deemed existing buildings regardless o existence of a legal permit or a certificate of occupancy. (Del) EXISTING STRUCTURE. Delete without substitution. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Mechanical Code Page CHAPTER 13 - FUEL OIL PIPING AND STORAGE (Amd) 1301.1 Scope. This chapter and the 2022 Connecticut Fire Safety Code and 2022 Connecticut Prevention Code shall govern the design, installation, construction and repair of fuel oil storage and pi systems. The storage of fuel oil and flammable and combustible liquids shall be in accordance wit - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Existing Building Code Page (Add) 306.7.17 Assembly seating. Where it is technically infeasible to disperse accessible se throughout an altered assembly area, accessible seating areas may be clustered. Each accessible wheel space shall have provisions for companion seating and shall be located on an accessible route that serves as an accessible means of egress. (Amd) 307.1 Smoke alarms in existing portions of a building. Where an addition or alteration is to a building or structure of a Group I-4 and E day care facilities, Group I-1 or R occupancy or when or more sleeping rooms are added or created in existing dwelling units, the entire dwelling unit or buil shall be provided with smoke detectors located as required for new buildings. Such smoke detectors w existing spaces may be battery operated and are not required to be dual-powered or interconnected u other remodeling considerations require removal of wall and ceiling coverings which would facil concealed interconnected wiring. (Amd) 308.1 Carbon monoxide alarms in existing portions of a building. Where an additio alteration is made to a building or structure of Group I-1, I-2, I-4, R, and E occupancy, the existing buil shall be provided with carbon monoxide alarms in accordance with Section 915.7 of the 2021 Internati Building Code portion of the 2022 State Building Code. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Add) R320.4.2 Design flood elevation. The required number of Type B units shall not apply to where the lowest floor is required to be at or above the design flood elevation resulting in both o following: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2020 NFPA 70 National Electrical Code Page - (Amd) 250.68(C) Grounding Electrode Conductor Connections. Grounding electrode conductor bonding jumpers shall be permitted to be connected at the following locations and used to exten connection to an electrode(s): (1) Interior metal water piping that is electrically continuous with a metal underground water pipe elect and is located not more than 1.52 m (5 ft) from the point of entrance to the building shall be permitt extend the connection to an electrode(s). Interior metal water piping located more than 1.52 m (5 ft) the point of entrance to the building shall not be used as a conductor to interconnect electrodes o grounding electrode system. Exception: In industrial, commercial, and institutional buildings or structures, if conditions of mainten and supervision ensure that only qualified persons service the installation, interior metal water p located more than 1.52 m (5 ft) from the point of entrance to the building shall be permitted as a bon conductor to interconnect electrodes that are part of the grounding electrode system, or as a groun electrode conductor, if the entire length, other than short sections passing perpendicularly through floors, or ceilings, of the interior metal water pipe that is being used for the conductor is exposed. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page ds = Depth of water on the undeflected roof up to the inlet of secondary drainage system when the prim drainage system is blocked (in other words, the static head), in inches (mm). R = Rain load on the undeflected roof, in psf (kN/m2). Where the phrase “undeflected roof” is u deflections from loads (including dead loads) shall not be considered when determining the amoun rain on the roof. (Del) Figures 1611.1(1) through 1611.1(5) . Delete all figures. (Amd) 1612.3 Establishment of flood hazard areas. Flood hazard areas shall be established locally methods lawfully adopted by the town, city or borough. (Amd) 1613.2.1 Mapped acceleration parameters. The parameters Ss and S1 shall be determined fr the MCE spectral response accelerations shown in Appendix P. (Del) Figures 1613.2.1(1) through 1613.2.1(10). Delete all figures. CHAPTER 17 - SPECIAL INSPECTIONS AND TESTS - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Existing Building Code Page (Add) 101.10.1 Construction documents. The construction documents for Alterations – Lev Alterations – Level 3, additions and changes of occupancy shall show in sufficient detail the loca construction, size and character of all portions of the means of egress in compliance with the provisio this code. The construction documents shall designate the number of occupants to be accommodat every work area of every floor and in all affected rooms and spaces. (Del) SECTION 103 CODE COMPLIANCE AGENCY. Delete in its entirety and refer to Section of the 2021 International Building Code portion or Section R103 of the 2021 International Reside Code portion, as applicable, of the 2022 Connecticut State Building Code – Code Compliance Agenc (Del) SECTION 104 DUTIES AND POWERS OF CODE OFFICIAL. Delete in its entirety and to Section 104 of the 2021 International Building Code portion or Section R104 of the 2021 Internat Residential Code portion, as applicable, of the 2022 Connecticut State Building Code – Duties and Po of the Building Official. (Del) SECTION 105 PERMITS. Delete in its entirety and refer to Section 105 of the 2021 Internati Building Code portion or Section R105 of the 2021 International Residential Code portion, as applic of the 2022 Connecticut State Building Code – Permits. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) R105.5 Expiration of permit. Every permit issued shall become invalid unless the work author by such permit is commenced within 180 days after its issuance or after commencement of work if than 180 days pass between inspections. The building official is authorized to grant, in writing, one or extensions of time, for periods of not more than 180 days each. The extension shall be requested in wr and justifiable cause shall be demonstrated. Exception: The building official may specify an expiration date of not less than 30 days, nor than 180 days, for commencement of work under permits issued to abate unsafe conditions pursua Section R115 of this code. Work performed under such permits shall be completed as expeditious possible. (Add) R105.5.1 Nine-year closure. Pursuant to subsection (c) of section 29-265 of the Connec General Statutes, 9 years from the date of issuance of a building permit issued pursuant to section 29 for construction or alteration of a one-family dwelling, two-family dwelling or structure located on the s parcel as a one-family dwelling or two-family dwelling, for which construction or alteration a certifica occupancy, as defined in the regulations adopted pursuant to section 29-252, has not been issued b building official, such building permit shall be deemed closed. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 1705.5.2 Metal-plate-connected wood trusses. Where a truss has an overall height of 60 in (1524 mm) or greater, the special inspector shall verify that the permanent individual truss me restraint/bracing is installed in accordance with the approved truss submittal package. Where a truss span is 60 feet (18 288 mm) or greater, the special inspector shall verify that the temporary install restraint/bracing and the permanent individual truss member restraint/bracing are installed in accord with the approved truss submittal package. (Amd) 1705.12 Special inspections for wind-resisting components. Periodic special inspecti required for fastening of roof covering and wall covering in wind Exposure Category C or D, where - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 3103.5.8 Temporary air-supported and air-inflated membrane structures. In addition to applicable requirements of Section 3103.5, temporary air-supported and air-inflated membrane struc shall be in accordance with Sections 3103.5.8.1 to 3103.5.8.4, inclusive. (Add) 3103.5.8.1 Door operation. In high winds greater than 50 miles per hour (22 m/s) or in conditions, the use of doors in air-supported structures shall be controlled to avoid excessive air loss. shall not be left open under any condition. (Add) 3103.5.8.2 Fabric envelope design and construction. Air-supported and air-inflated structures have the design and construction of the fabric envelope and the method of anchoring in accordance Architecture Fabric Institute ASI 77. (Add) 3103.5.8.2.1 Inflation pressure. Operating pressure in air-supported and air-inflated structures be maintained at the design pressure specified by the manufacturer to assure stability and to avoid exce distortion during high wind or snow loads. (Add) 3103.5.8.3 Blowers. An air-supported structure used as a place of assembly shall be furnished not less than two blowers, each of which has adequate capacity to maintain full inflation pressure normal leakage. The design of the blower shall be so as to provide integral limiting pressure at the d pressure specified by the manufacturer. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 116.7.1 Penalty. Pursuant to the provisions of section 29-394 of the Connecticut General Stat any person who, by himself or his agent, fails to comply with the written order of a building inspecto the provision of additional exit facilities in a building, the repair or alteration of a building or the rem of a building or any portion thereof, shall be fined not less than two hundred nor more than one thou dollars or imprisoned not more than six months, or both. (Add) SECTION 117 – EMERGENCY MEASURES - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Del) FIGURE R301.2.1 COMPONENT AND CLADDING PRESSURE ZONES. Delete figure i entirety and replace with the following: (Add) FIGURE R301.2.1 COMPONENT AND CLADDING PRESSURE ZONES. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) WIND-BORNE DEBRIS REGION. Areas within municipalities or portions thereof as tabul in Appendix P, that are: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Table of Contents This page is intentionally left blank. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) R105.2 Work exempt from permit. Exemption from the permit requirements of this code not be deemed to grant authorization for any work to be done in any manner in violation of the provis of this code or any other laws, statutes, regulations or ordinances of the jurisdiction. Permits shall n required for the following work: Building: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page been provided with a statement signed by the architect or professional engineer and the general contr stating that the completed structure or addition is in substantial compliance with the approved plans on (Add) 111.1.3.1 Threshold structures. No certificate of occupancy shall be issued for a proposed stru or addition that exceeds the threshold limits cited in Section 107.7 until the building official has provided with statements of professional opinion signed by the architect of record, the professi engineer of record responsible for the design of the structure or addition and the general contra affirming that the completed construction is in substantial compliance with the approved plans and de specifications. If fabricated structural load-bearing members or assemblies are used in the construction building official shall be provided with statement(s) of professional opinion signed by the professi engineer(s) responsible for the design of such members or assemblies, affirming that the compl fabrication is in substantial compliance with the approved design specifications. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) Table R301.2.1(1) COMPONENT AND CLADDING LOADS FOR A BUILDING WIT MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (ASD). Add footnote: h. For Ultimate Design Wind Speeds (Vult)between those given, the loads shall be interpolated. (Del) FIGURE R301.2.1.1 REGIONS WHERE WIND DESIGN IS REQUIRED. Delete without substitution. (Del) R301.2.1.3 Wind speed conversion. Delete without substitution. (Del) TABLE 301.2.1.3 WIND SPEED CONVERSIONS. Delete without substitution. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Pag (Add) 104.10.2 Accessibility exemption. Pursuant to subsection (b) of section 29-269 of the Connec General Statutes, any variation of or exemption from any provisions relating to accessibility to, use of egress from, buildings and structures as required herein shall be permitted only when approved by the Building Inspector. Pursuant to subsection (b) of section 29-269 of the Connecticut General Statutes, person aggrieved by the decision of the State Building Inspector may appeal to the Codes and Stand Committee within 30 days after such decision has been rendered. (Add) 104.10.3 Historic structures exemption. Pursuant to section 29-259 of the Connecticut Ge Statutes, exemptions may be granted to the provisions of this code for historic structures, as describ - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Introduction Pag This page is intentionally left blank - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Plumbing Code Page (Amd) 107.2 Retention of construction documents. The building official shall retain one set of appr construction documents for a period as set forth in the records/disposition schedule adopted pursua chapter 188 of the Connecticut General Statutes. Exception: Pursuant to subsection (e) of section 29-261 of the Connecticut General Statutes, receipt of a written request signed by the owner of plans and specifications on file for a si family dwelling or out-building, the building official shall immediately return the original p and specifications to the owner after a certificate of occupancy is issued with respect to the p and specifications. (Del) SECTION 113 MEANS OF APPEALS Delete this section in its entirety and refer to Section of the 2021 International Building Code portion of the 2022 Connecticut State Building Code – Mea Appeal. (Del) SECTION 114 BOARD OF APPEALS Delete this section in its entirety and refer to Section of the 2021 International Building Code portion of the 2022 Connecticut State Building Code – Mea Appeal. (Add) 115.2.1 Written notice. The notice of violation shall be in writing and shall be given to the o of the property involved, or to the owner’s agent or to the person doing the work. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Existing Building Code Page (Amd) 306.7.8 Lifts and limited-use/limited-application elevators in existing buildings. Vertic incline platform lifts, inclined stairway chairlifts and limited-use/limited-application elevators shall n a part of an accessible route in existing buildings undergoing alteration or repair except that ve platform lifts and limited-use/limited-application elevators shall be permitted in existing buildings permitted in the locations set forth in Section 1110.9 of the International Building Code. Pursuant to se - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 1110.17 Automated teller machines. Where automated teller machines are provided for pedes use at any site, at least one location and one automated teller machine shall be accessible. (Amd) 1112.1 Signs. Required accessible elements shall be identified by the International Symb Accessibility at the following locations: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Mechanical Code Page CHAPTER 5 – EXHAUST SYSTEMS (Amd) 505.4 Makeup air required. Where one or more gas, liquid or solid fuel-burning appliance are neither direct-vent nor use a mechanical draft venting system are located within a dwelling unit barrier, each exhaust system capable of exhausting in excess of 400 cubic feet per minute (0.19 m3/s) be mechanically or passively provided with makeup air at a rate approximately equal to the exhaust air Such makeup air systems shall be equipped with not fewer than one damper complying with Se - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Energy Conservation Code Page - This page is intentionally left blank - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 118.2 Safeguarding vacant premises. Temporarily unoccupied buildings, structures, premis portions thereof shall be secured and protected in accordance with this section. (Add) 118.2.1 Security. Exterior openings and interior openings accessible to other tenants or unautho persons shall be boarded, locked, blocked or otherwise protected to prevent entry by unautho individuals. (Add) 118.2.2 Fire protection. Fire alarm, sprinkler and standpipe systems shall be maintained i operable condition at all times. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - Municipality Ultimate Design Wind Speed, Vult (mph) Nominal Design Wind Speed, Vasd (mph) Ground Snow Load pg (psf) Hurricane-Pro Region Thompson - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page for new construction. The carbon monoxide detectors shall have a power source in accordance with Se - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Add) R104.10.1.2 Records. The application for modification, variation, exemption or approv equivalent or alternative compliance and the decision of the State Building Inspector shall be in wr and shall be officially recorded with the application for a building permit in the permanent records o building department. (Add) R104.10.2 Accessibility exemption. Pursuant to subsection (b) of section 29-269 of the Connec General Statutes, any variation of or exemption from any provisions relating to accessibility to, use of egress from, buildings and structures as required in this code shall be permitted only when approved b State Building Inspector. Any person aggrieved by the decision of the State Building Inspector may ap to the Codes and Standards Committee within 30 days after such decision has been rendered. (Add) R104.10.3 Historic structures exemption. Pursuant to section 29-259 of the Connecticut Ge Statutes, exemptions may be granted to the provisions of this code for historic structures as describ - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Introduction Pag INTRODUCTION Adopted and Referenced Publications Pursuant to section 29-252 of the Connecticut General Statutes the following national model code amended herein, are adopted and shall be known as the 2022 Connecticut State Building Code: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 407.14.1.7 Fire alarm and detection systems. Fire alarm and detection systems shall be inst in accordance with Section 907.2.6. (Add) 407.14.1.8 Detection. Smoke detection shall be provided in all sleeping rooms, sleeping r hallways and common spaces except kitchens and bathrooms. (Add) 407.14.1.9 Carbon monoxide detectors. Carbon monoxide detectors shall be provide accordance with Section 915. (Add) 407.14.1.10 Attic space access. An opening not less than 36 inches by 36 inches (914 mm by mm) shall be provided to any attic area having a clear height of over 30 inches (762 mm). Clear headr of not less than 30 inches (762 mm) shall be provided at the attic space at or above the opening. Exception: In conversions of a single-family home, a rough framed opening of 30 inches by 22 in (762 mm by 559 mm) shall be permitted from a hallway or other readily accessible location. (Add) 407.14.1.11 Standby power. Standby power shall be provided for small Group I-2 hom accordance with Section 2702. (Add) 407.14.2 Alternative compliance. Where the requirements of Section 407.14.1 are satisfied, s Group I-2 homes shall be permitted to comply with Sections 407.14.2.1 through 407.14.2.3. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - APPENDIX AE - MANUFACTURED HOUSING USED AS DWELLINGS (Amd) AE101.1 General. The provisions of Appendix AE shall be applicable only to a manufactured used as a single dwelling unit and shall apply to the following: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 1005.3.2 Other egress components. The capacity, in inches, of means of egress components than stairways shall be calculated by multiplying the occupant load served by such component means of egress capacity factor of 0.2 inch (5.1 mm) per occupant. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Swimming Pool and Spa Code Page - AMENDMENTS TO THE 2021 INTERNATIONAL SWIMMING POOL AND SPA CODE CHAPTER 1 – SCOPE AND ADMINISTRATION (Amd) 101.1 Title. The 2021 International Swimming Pool and Spa Code shall be known as the International Swimming Pool and Spa Code portion of the 2022 Connecticut State Building hereinafter referred to as “the code” or “this code”. (Amd) 102.5 Historic buildings. Pursuant to section 29-259 of the Connecticut General Stat exemptions may be granted to the provisions of this code for historic structures, as described in sectio - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - Plumbing: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) R310.6 Dwelling additions. Where dwelling additions contain sleeping rooms, an emerg escape and rescue opening shall be provided in each new sleeping room. Where dwelling additions basements, an emergency escape and rescue opening shall be provided in the new habitable basemen Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Add) R315.2.3 During construction. Pursuant to section 29-315b of the Connecticut General Stat whenever a dwelling is occupied during interior alterations or additions requiring a building permit a fuel-burning appliance, fireplace or attached garage exists, the temporary installation of battery-ope carbon monoxide alarms shall be required in the vicinity of such alterations or additions for the durati construction activities. A combined smoke and carbon monoxide alarm may be installed to comply Section R314.2.3 and this section. (Amd) R315.3 Location. Carbon monoxide alarms in dwelling units shall be installed outside of separate sleeping area in the immediate vicinity of the bedrooms and on each additional habitable lev the dwelling unit. Where a fuel-burning appliance is located within a bedroom or its attached bathro carbon monoxide alarm shall be installed within the bedroom. The alarm shall be clearly audible i bedrooms over background noise levels with all intervening doors closed. (Del) FIGURE R318.4 TERMITE INFESTATION PROBABILITY MAP. Delete without substitution. (Del) SECTION R320 – ACCESSIBILITY. Delete section in its entirety and replace with the follo (Add) SECTION R320 – ACCESSIBILITY - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Energy Conservation Code Page AMENDMENTS TO THE 2021 INTERNATIONAL ENERGY CONSERVATION CO IECC – COMMERCIAL PROVISIONS CHAPTER 1 [CE] – SCOPE AND ADMINISTRATION (Amd) C101.1 Title. The 2021 International Energy Conservation Code as amended in this section be known as the 2021 International Energy Conservation Code portion of the 2022 State Building hereinafter referred to as “the code” or “this code”. (Amd) C101.5 Compliance. Residential buildings shall meet the provisions of IECC – Reside Provisions. Commercial buildings shall meet the provisions of IECC – Commercial Provisions. Exception: Temporary structures are exempt from the requirements of this code. (Amd) C101.5.1 Compliance materials. The code official shall be permitted to approve specific com software, worksheets, compliance manuals and other similar materials that meet the intent of this cod (Add) C101.5.2 Energy efficiency standards for products. In addition to the requirements of this the testing, certification and enforcement of efficiency standards for new products sold, offered for sa installed in the state of Connecticut shall comply with regulations adopted pursuant to section 16a-48 o Connecticut General Statutes. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Plumbing Code Page Statutes to practice such individual’s respective design profession and acting within the scope of his o license and practice discipline. CHAPTER–3 - GENERAL REGULATIONS (Amd) 305.4 Freezing. A water, soil or waste pipe shall not be installed outside of a building, or conce in outside walls or in any place subjected to freezing temperature, unless adequate provision is ma protect such pipe from freezing by insulation or heat or both. Water service pipe shall be installed not than 48 inches deep. (Del) 305.4.1 Sewer depth. Delete section. (Amd) TABLE 308.5 HANGER SPACING PIPING MATERIAL MAXIMUM HORIZONTAL SPACING (feet) SP Acrylonitrile butadiene styrene (ABS) pipe - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - Exposure D. Exposure D shall apply where the ground surface roughness, as defined by Sur Roughness D, prevails in the upwind direction for a distance of at least 5,000 feet (1524 m) or 20 ti the height of the building, whichever is greater. Exposure D shall also apply where the ground sur roughness immediately upwind of the site is B or C, and the site is within a distance of 600 feet ( m) or 20 times the building height, whichever is greater, from an Exposure D condition, as define the previous sentence. (Del) R301.2.1.5 Topographic wind effects. Delete without substitution. (Del) R301.2.1.5.1 Simplified topographic wind speed-up method. Delete without substitution. (Del) Table R301.2.1.5.1 ULTIMATE DESIGN WIND SPEED MODIFICATION TOPOGRAPHIC WIND EFFECT. Delete without substitution. (Del) FIGURE R301.2.1.5.1(1) TOPOGRAPHIC FEATURES FOR WIND SPEED-UP EFFE Delete without substitution. (Del) FIGURE R301.2.1.5.1(2) ILLUSTRATION OF WHERE ON A TOPOGRAPHIC FEATU WIND SPEED INCREASE IS APPLIED. Delete without substitution. (Del) FIGURE R301.2.1.5.1(3) UPWIND OBSTRUCTION. Delete without substitution. (Del) R301.2.2 Seismic provisions. Delete section and all of its subsections without substitution. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 113.5 Appointment of a panel. Upon receipt of an appeal from an owner or his agent, or appr of an appeal by a person other than the owner or his agent, the chairperson of the municipal board of ap shall appoint a panel of not less than three members of such board to hear such appeal. (Add) 113.6 Rendering of decisions. The panel shall, upon majority vote of its members, affirm, m or reverse the decision of the building official in a written decision upon the appeal and file such deci with the building official from whom such appeal has been taken not later than five days, exclusi Saturdays, Sundays and legal holidays, following the day of the hearing thereon. A copy of the deci shall be mailed, prior to such filing, to the party taking the appeal. (Add) 113.7 Appeal to the Codes and Standards Committee. Any person aggrieved by the decision municipal board of appeals may appeal to the Codes and Standards Committee within 14 days afte filing of the decision with the building official in accordance with the provisions of section 29-266 o Connecticut General Statutes. (Add) 113.8 Court review. Any person aggrieved by any ruling of the Codes and Standards Comm may appeal to the Superior Court for the judicial district where such building or structure has been being erected. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Mechanical Code Page AMENDMENTS TO THE 2021 INTERNATIONAL MECHANICAL CODE CHAPTER 1 – SCOPE AND ADMINISTRATION (Amd) 101.1 Title. The 2021 International Mechanical Code as amended in this section shall be kn as the 2021 International Mechanical Code portion of the 2022 Connecticut State Building C hereinafter referred to as “the code” or “this code”. (Amd) 101.2 Scope. This code shall regulate the design, installation, maintenance, alteration and inspe of mechanical systems that are permanently installed and utilized to provide control of environm conditions and related processes within buildings. This code shall also regulate those mechanical syst system components, equipment and appliances specifically addressed herein. The installation of fue distribution piping and equipment, fuel-gas-fired appliances and fuel-gas-fired appliance venting sys shall be in accordance with Section 101.2.2. Exception: Detached one- and two-family dwellings and townhouses not more than three stories a grade plane in height with a separate means of egress and their accessory structures not more than stories above grade plane in height shall comply with this code or the International Residential C (Amd) 101.2.1 Appendices. The provisions of Appendix A shall be considered applicable to the utiliz of this code. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 903.2.7 Group M. An automatic sprinkler system shall be provided throughout buildings contai a Group M occupancy where one of the following conditions exists: - pdf_text
2022 2022 Connecticut State Fire Prevention Code. These requirements apply to liquid petroleum sto systems, gas piping systems extending from the point of delivery to the inlet connections of applia the installation and operation of residential and commercial gas appliances and related accessori covered by this code. (Add) 101.2.3 Oil-burning equipment, piping and storage. In addition to the requirements of this c the installation of oil burners, equipment, and appliances used in connection therewith, including ta piping, pumps, control devices and accessories shall comply with NFPA 31, as incorporated in the Connecticut State Fire Safety and the 2022 Connecticut State Fire Prevention Code. (Add) 101.2.4 Electrical. The provisions of NFPA 70, National Electrical Code, shall apply to installation of electrical systems, including alterations, repairs, replacement, equipment, applia fixtures, fittings and appurtenances thereto. (Add) 101.2.5 Fire prevention. References to the International Fire Code within the body of the document shall be considered to be references to the 2022 Connecticut State Fire Safety Code. (Amd) 102.6 Historic buildings. Pursuant to section 29-259 of the Connecticut General Stat exemptions may be granted to the provisions of this code for historic structures, as described in se - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Existing Building Code Page (Del) 706.3.2 Roof diaphragms resisting wind loads in high-wind regions. Delete section in its enti CHAPTER 8 – ALTERATIONS – LEVEL 2 (Amd) 804.2 General. The means of egress shall comply with the requirements of this section. Exception: Where the work area and the means of egress serving it complies with the 2022 Connec State Fire Prevention Code. (Amd) 804.4.3 Main Entrance – Group A. In Group A occupancies renovated or altered to incr capacity that have a single main entrance, such main entrance shall also be the main exit. The entrance/exit shall be of sufficient width to accommodate not less than two-thirds of the occupant load such width shall not be less than the total required width of all means of egress leading to the exit. remaining exits shall be capable of providing at least one-half of the total required exit capacity. Exception: In assembly occupancies where there is no well-defined main entrance and main e where multiple main entrances and main exits are provided, exits shall be permitted to be distri around the perimeter of the building or space containing the assembly occupancy, provided the width of egress is not less than 100 per cent of the required width. CHAPTER 10 – CHANGE OF OCCUPANCY - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Existing Building Code Page (Del) SECTION 114 – STOP WORK ORDER. Delete in its entirety and refer to Section 115 of the International Building Code portion or Section R114 of the 2021 International Residential Code por as applicable, of the 2022 Connecticut State Building Code – Stop Work Order. (Del) SECTION 115 – UNSAFE BUILDINGS AND EQUIPMENT. Delete in its entirety and ref - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - AMENDMENTS TO THE 2021 INTERNATIONAL RESIDENTIAL CODE CHAPTER 1 – SCOPE AND ADMINISTRATION (Amd) R101.1 Title. The 2021 International Residential Code and this section shall be known as the International Residential Code portion of the 2022 Connecticut State Building Code, hereinafter ref to as “the code” or “this code.” (Amd) R101.2 Scope. The provisions of this code shall apply to the construction, alteration, move enlargement, replacement, repair, equipment, use and occupancy, location, removal and demoliti detached one- and two-family dwellings and townhouses not more than three stories above grade pla height with a separate means of egress and their accessory structures not more than three stories a grade plane in height. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page CHAPTER 35 – REFERENCED STANDARDS (Amd) ASME American Society of Mechanical Engineers Two Park Avenue New York, NY 10016 (Amd) NFPA National Fire Protection Association - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Pag AMENDMENTS TO THE 2021 INTERNATIONAL BUILDING CODE CHAPTER 1 – SCOPE AND ADMINISTRATION (Amd) 101.1 Title. The 2021 International Building Code as amended in this section shall be known a - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/2022 Amendments to the 2021 International Building Code Page - 66 Municipality Basic Design Wind Speeds, V (mph) Allowable Stress Design Wind Speeds, Vasd (mph) Ground Snow Load pg (psf) MCE Ground Accelerations Wind-Borne Debris Region1 Hurricane- Prone Region Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV SS (g) S1 (g) Risk Cat. III Occup. I-2 Risk Cat. IV New Milford - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Mechanical Code Page (Add) LIMITED-COMBUSTIBLE MATERIAL. A material shall be considered a limited-combu material where both of the conditions 1 and 2 below and conditions 3 or 4 below are met. Conditions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - Municipality Ultimate Design Wind Speed, Vult (mph) Nominal Design Wind Speed, Vasd (mph) Ground Snow Load, pg (psf) Hurricane-Pro Region New Haven - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) R324.4.1.1 Roof load. Portions of roof structures not covered with photovoltaic panel systems be designed for dead loads and roof loads in accordance with Sections R301.4 and R301.6. Portions of structures covered with photovoltaic panel systems shall be designed for the following load cases: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Energy Conservation Code Page - (Amd) R406.5 ERI-based compliance. Compliance based on an ERI analysis requires that the proposed design and confirmed built dwelling unit be shown to have an ERI or a Home Energy R System (HERS) value less than or equal to 55. Compliance shall be demonstrated without the use o site renewable energy. (Del) Table R406.5 MAXIMUM ENERGY RATING INDEX. Delete without substitution. R406.7.2.1 Proposed compliance report for permit application. Compliance reports submitted wit application for a building permit shall include the following: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Mechanical Code Page (Amd) TABLE 305.4 PIPING SUPPORT SPACINGa PIPING MATERIAL MAXIMUM HORIZONTAL SPACING (feet) MA VE SPAC ABS pipe - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Existing Building Code Page (Amd) 1011.2.2 Fire alarm and detection system. Where a change in occupancy classification occu where there is a change of occupancy within a space where there is a different fire protection sy threshold requirement in Chapter 9 of the International Building Code that requires a fire alarm detection system to be provided based on the new occupancy in accordance with Chapter 9 of International Building Code, such system shall be provided throughout the building or the area wher change of occupancy occurs. Existing alarm notification appliances shall be automatically activ throughout the building. Where the building is not equipped with a fire alarm system, alarm notific appliances shall be provided throughout the area where the change of occupancy occurs in accordance - pdf_text
2022 2022 Connecticut State Building Code. (Amd) 502.7 Identification. Accessible parking spaces shall be identified by above grade sign accordance with Section 1112.1 of the 2021 International Building Code portion of the 2022 Connec State Building Code. (Del) 504 Stairways. Delete section in its entirety. (Del) 505 Handrails. Delete section in its entirety and replace with the following: (Add) 505 Handrails. (Add) 505.1 General. Handrails shall be provided in accordance with Section 1014 of the International Building Code portion of the 2022 Connecticut State Building Code. (Amd) 607.5 Controls. Controls, other than drain stoppers, shall be provided on an end wall, lo between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline o width of the bathtub. Controls shall comply with Section 309.4. Exception: Controls in Group I-2 long-term health care that provide supervised, assisted bat may be located outside of the bathtub compartment. (Amd) 608.4 Controls and hand showers. Controls and hand held showers shall comply with Sec - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Add) APPENDIX AY – WIND SPEEDS, SEISMIC DESIGN CATEGORIES and GRO SNOW LOADS Municipality Ultimate Design Wind Speed, Vult (mph) Nominal Design Wind Speed, Vasd (mph) Ground Snow Load, pg (psf) Hurricane-Pro Region Andover - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 308.5.4 Family child care home. A family child care home, as described in section 19a-77 o Connecticut General Statutes, that operates in accordance with the licensing requirements of the Offi Early Childhood shall be classified as Group R-3 or shall comply with the International Residential (Amd) 310.1 Residential Group R. Residential Group R includes, among others, the use of a buildi structure, or a portion thereof, for sleeping purposes when not classified as an Institutional Group I or not regulated by the International Residential Code. Group R occupancies not constructed in accord with the International Residential Code as permitted by Section 101.2 shall comply with Section 420. (Amd) 310.2 Residential Group R-1. Residential Group R-1 occupancies containing sleeping units the occupants are primarily transient in nature, including: Bed and breakfast establishments Boarding houses (transient) with more than 10 occupants Congregate living facilities (transient) with more than 10 occupants Hotels (transient) Motels (transient) (Add) 310.2.1 Group R-1 bed and breakfast establishments. A building that does not qualify as a or two-family dwelling unit in accordance with Section 101.2 and: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - expanding foam applied in accordance with the manufacturer’s instructions. In addition, slab j inclusive of cracks, penetrations, expansion joints and the slab to foundation connections, shall be with polyurethane caulk. (Add) AF105.4 Sumps. Sumps open to soil or serving as the termination point for subslab or exterior tile loops shall be covered with a gasketed or sealed lid. Sumps used as the suction point in a su depressurization system shall have a lid designed to accommodate the vent pipe. Sumps used as a drain shall have a lid equipped with a trapped inlet. (Add) AF105.5 Waterproofing and dampproofing. The exterior surfaces of foundation walls b grade shall be waterproofed or dampproofed in accordance with Section R406. (Add) AF105.6 Power source for future radon fan. To provide for future installation of a potential r fan Section AF104.6.1 or AF104.6.2 shall be met. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Mechanical Code Page (Add) 506.3.2.5.3 Water test. The water test shall be performed by use of a pressure washer operati a minimum of 1500 psi (10342 kPa), simulating cleaning operations. The water shall be applied direct all areas to be tested. No water applied to the duct interior shall be visible on any exterior surface in volume during the test. (Amd) 506.3.6 Grease duct clearances. Where enclosures are not required, grease duct systems exhaust equipment serving a Type I hood shall have a clearance to combustible construction of at lea inches (457 mm), 3 inches (76 mm) to limited-combustible material, and 0 inches (0 mm) to noncombu material. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Pag (Amd) 105.3.1 Action on application. Pursuant to section 29-263 of the Connecticut General Statutes building official shall examine or cause to be examined applications for permits and amendments th within 30 days after filing and either issue or deny a permit within such 30-day period. If the applic or construction documents do not conform to the requirements of this code and pertinent laws, the buil official shall reject such application in writing, stating the reasons therefor. If the building offici satisfied that the proposed work conforms to the requirements of this code and applicable laws, the buil official shall issue a permit therefor as soon as practicable. In order to meet the 30-day requiremen forth herein, construction documents shall be submitted by the applicant to both the building official the local fire marshal, concurrently. (Add) 105.3.1.1 Zoning approval. Pursuant to subsection (f) of section 8-3 of the Connecticut Ge Statutes, no building permit shall be issued, in whole or in part, for a building, structure or use subje the zoning regulations of a municipality without certification in writing by the official charged wit enforcement of such regulations that such building, structure or use is in conformity with such regulat or is a valid nonconforming use under such regulations. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page may be battery operated and are not required to be dual-powered or interconnected unless other remod considerations require removal of wall and ceiling coverings which would facilitate conce interconnected wiring. (Add) 907.2.11.2.2.1 During construction. Pursuant to section 29-315b of the Connecticut General Statutes, whenever a single-family or two-family dwelling is occupied during interior alterations or additions requiring a building permit, the temporary installation of battery-operated smoke alarms sha required in the vicinity of such alterations or additions for the duration of construction activities. A combined smoke and carbon monoxide alarm may be installed to comply with Section 915.8 and this section. (Add) 907.2.11.2.3 Group I-4 and Group E day care facilities. Single- or multiple-station s detectors shall be installed and maintained in all day care facilities in the following locations: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES (Add) 704.6.2 Connections. Where non-fire-resistance-rated members attach to fire-resistance- members, the nonrated member shall be protected in the same manner as the rated member for a dist of not less than 12 inches (305 mm) from the point of connection. (Amd) 708.1 General. The following wall assemblies shall comply with this section. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Plumbing Code Page AMENDMENTS TO THE 2021 INTERNATIONAL PLUMBING CODE CHAPTER 1 – SCOPE AND ADMINISTRATION (Amd) 101.1 Title. The 2021 International Plumbing Code as amended in this section shall be know the 2021 International Plumbing Code portion of the 2022 Connecticut State Building Code, herein referred to as “the code” or “this code”. (Amd) 101.2 Scope. The provisions of this code shall apply to the erection, installation, alteration, rep relocation, replacement, addition to, use or maintenance of plumbing systems within the stat Connecticut. This code shall also regulate nonflammable medical gas, inhalation anesthetic, vacuum pi nonmedical oxygen systems and sanitary and condensate vacuum collection systems. The installati fuel gas distribution piping and equipment, fuel gas-fired water heaters and water heater venting sys shall be regulated in accordance with Section 101.2.1. The provisions of appendices B, C, D and E sh considered part of this code. Exception: Detached one- and two-family dwellings and multiple single-family dwel (townhouses) not more than three stories high with separate means of egress and their acce structures shall comply with the 2021 International Residential Code portion of the 2022 Connec State Building Code. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 110.3.13 Electrical inspections. Required electrical inspections shall include installation temporary services prior to activation; installation of underground piping and conductors after trenche excavated and bedded and before backfill is put in place; rough inspections of installed wiring components after the roof, framing, fireblocking and bracing are complete and prior to concealment; final inspection after all work required by the permit is complete. (Add) 110.6.1 Notification of inspection results. Notification as to passage or failure, in whole or in of any required inspection shall be made in writing by the building official or his duly author representative and shall be left at the job site or delivered to the permit holder. It shall be the duty o permit holder to ascertain the results of required inspections. Notifications may be delivered electronic - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 1705.5 Wood construction. Special inspections of prefabricated wood structural elements assemblies shall be in accordance with Section 1704.2.5. Special inspections of site-built wood struc elements and assemblies shall be in accordance with this section and Table 1705.5. Exceptions: Special inspections, other than Items 5(a) and 5(b) of Table 1705.5, of site-built structural assemblies shall not be required in the following cases: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Energy Conservation Code Page (Add) C105.7 Posting of required inspections. A schedule of required inspections shall be compile the code official. The schedule shall be posted in the building department for public view. (Add) C105.8 Notification of inspection and testing results. Notification as to passage or failure, in w or in part, of any required inspection or test shall be made in writing by the building official or his authorized representative and shall be left at the job site or delivered to the permit holder. It shall b duty of the permit holder to ascertain the results of required inspections. (Del) SECTION C106 - NOTICE OF APPROVAL. Delete in its entirety and refer to Section 111 the 2021 International Building Code portion of the 2022 Connecticut State Building Code. (Amd) C108.1 Referenced codes and standards. The codes and standards referenced in this code sh those listed in Chapter 6, and such codes and standards shall be considered as part of the requiremen this code to the prescribed extent of each such reference and as further regulated in Sections C108.1. C108.1.2. Any reference to an ICC code adopted as part of the 2022 Connecticut State Building Co the 2022 Connecticut State Fire Safety Code shall mean a reference to such ICC code as amended b state of Connecticut. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - Buildings approved in writing by such an energy efficiency program shall be considered in compliance this chapter. The requirements identified as “mandatory” in this chapter of this code, as applicable, sh met. (Add) N1101.10.1.1.1 (R402.2.14) Foamed-in-place insulating material. Pursuant to section 29-2 the Connecticut General Statutes, foamed-in-place insulating material, except urethane foam insulati styrene foam insulation, shall not be sold or installed in this state on or after May 28, 2013, unles manufacturer or supplier has certified to the State Building Inspector that the material complies wit provisions of that section. (Add) N1101.15 (R101.5.2) Energy efficiency standards for products. In addition to the requireme this code, the testing, certification and enforcement of efficiency standards for new products sold, of for sale or installed in the state of Connecticut shall be in compliance with section 16a-48 of the Connec General Statutes and any regulations adopted under authority of said statute. (Amd) N1102.1 (R402.1) General (Prescriptive). The building thermal envelope shall meet requirements of Sections N1102.1.1 through N1102.1.5. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to ICC/ANSI A117.1 - 2017 Page (Add) Figure 304.3.2 T-Shaped Space. (Del) 305.3 Size. Delete section, subsections and figures and replace with the following: (Add) 305.3 Size. The clear floor space shall be 48 inches (1220 mm) minimum in length and 30 in (760 mm) minimum in width. (Add) Figure 305.3 Size of Clear Floor Space. (Amd) 502.2 Vehicle space size. Pursuant to section 14-253a of the Connecticut General Statutes parking spaces shall be 15 feet in width including 5 feet of cross hatch. Van parking spaces shall be 16 in width including 8 feet of cross hatch. (Del) Fig. 502.2(A) Vehicle parking space size. Delete figure without substitution. (Del) Fig. 502.2(B) Vehicle parking space size. Delete figure without substitution. (Del) Fig. 502.4 Parking space access aisle. Delete figure without substitution. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Pag (Amd) 104.1 General. The building official is hereby authorized and directed to enforce the provisio this code. The building official shall have the authority to adopt policies and procedures to clarif application of its provisions. Such policies and procedures shall comply with the intent and purpose of code. Such policies and procedures shall not have the effect of waiving requirements specifically prov for in this code, nor shall they have the effect of establishing requirements in excess of those set for this code. (Add) 104.1.1 Rule-making authority. Pursuant to subsection (a) of section 29-252 of the Connec General Statutes, the State Building Inspector and the Codes and Standards Committee shall, jointly, the approval of the Commissioner of Administrative Services, adopt and administer a State Building for the purpose of regulating the design, construction and use of buildings or structures to be erected the alteration of buildings or structures already erected and make such amendments thereto as they, time to time, deem necessary or desirable. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) AF103.6.1 “T” fitting and vent pipe. Before a slab is cast or other floor system is installed, fitting shall be inserted below the slab or other floor system and the soil-gas-retarder. The “T” fitting be connected to a vent pipe. The vent pipe shall extend through the conditioned space of the dwellin terminate not less than 12 inches (305 mm) above the roof in a location not less than 10 feet (3048 away from any window or other opening into the conditioned spaces of the building that is less than (610 mm) below the exhaust point. The vent pipe shall be the same diameter throughout its length and be supported in accordance with Section P2605. (Amd) AF103.6.2 Multiple vent pipes. In dwellings where interior footings or other barriers separat gas-permeable layer, each area shall be fitted with an individual vent pipe. Vent pipes shall connect single vent that terminates not less than 12 inches (305 mm) above the roof or each individual vent shall terminate separately not less than 12 inches (305 mm) above the roof. The vent pipe shall be the diameter throughout its length and shall be supported in accordance with Section P2605. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2020 NFPA 70 National Electrical Code Page - (B) Insulated Equipment Grounding Conductors and Insulated Equipment Bonding Jumpers. (1) General. The following shall be directly connected to an insulated copper equipment groun conductor that is clearly identified along its entire length by green insulation and installed with the br circuit conductors in the wiring methods as provided in 517.13(A): (1) The grounding terminals of all receptacles other than isolated ground receptacles (2) Metal outlet boxes, metal device boxes, or metal enclosures (3) All non–current-carrying conductive surfaces of fixed electrical equipment likely to become ener that are subject to personal contact, operating at over 100 volts (4) Metal faceplates, by means of a metal mounting screw(s) securing the faceplate to a metal yoke or of a receptacle or to a metal outlet box Exception No. 1: For other than isolated ground receptacles, an insulated equipment bonding jumper directly connects to the equipment grounding conductor is permitted to connect the box and receptac to the equipment grounding conductor. Isolated ground receptacles shall be connected in accordance - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Add) R101.4.4 Connecticut State Fire Safety Code. References to the International Fire Code w the body of the model document shall be considered to be references to the 2022 Connecticut State Safety Code. (Add) R101.4.5 Applicable electrical code. The applicable electrical code for buildings constructed u this code is the 2020 NFPA 70 National Electrical Code portion of the 2022 Connecticut State Buil Code. (Add) R101.4.6 Demolition of structures. The demolition of structures shall be conducted in accord with the State Demolition Code as found in chapter 541 of the Connecticut General Statutes. (Amd) R102.4 Referenced codes and standards. The codes and standards referenced in this code sh considered part of the requirements of this code to the prescribed extent of each such reference a further regulated in Sections R102.4.1 and R102.4.2. Any reference to the ICC codes shall mean the Connecticut State Building Code adopted pursuant to section 29-252 of the Connecticut General Stat Exception: Where enforcement of a code provision would violate the conditions of the listing o equipment or appliance, the conditions of the listing and manufacturer’s instructions shall apply. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Add) SECTION R116 - EMERGENCY MEASURES (Add) R116.1 General. The procedures to be followed regarding emergency measures shall be as set in Section 117 of the 2021 International Building Code portion of the 2022 Connecticut State Bui Code. (Add) SECTION R117- VACANT BUILDINGS (Add) R117.1 General. Temporarily unoccupied buildings, structures, premises or portions the including tenant spaces, shall be safeguarded and maintained in accordance with Section 118 of the International Building Code portion of the 2022 Connecticut State Building Code. CHAPTER 2 – DEFINITIONS (Amd) R201.3 Terms defined in other codes. Where terms are not defined in this code and are defin other portions of the Connecticut State Building Code, such terms shall have the meanings ascribed to as in those portions. (Add) R202.1 Definitions. Add or amend the following definitions: (Add) ATTACHED DWELLING UNIT. A dwelling unit sharing demising walls, floors, ceilin common corridors with another dwelling unit or occupied space. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2020 NFPA 70 National Electrical Code Page - This page is intentionally left blank - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Mechanical Code Page Exception: Pursuant to subsection (e) of section 29-261 of the Connecticut General Statutes, receipt of a written request signed by the owner of plans and specifications on file for a single-fa dwelling or out-building, the building official shall immediately return the original plans specifications to the owner after a certificate of occupancy is issued with respect to the plans specifications. (Add) 112.2.6 Posting of required inspections. A schedule of required inspections shall be compile the code official. The schedule shall be posted in the building department for public view. (Add) 112.4 Notification of inspection and testing results. Notification as to passage or failure, in w or in part, of any required inspection or test shall be made in writing by the building official or his authorized representative and shall be left at the job site or delivered to the permit holder. It shall b duty of the permit holder to ascertain the results of required inspections. (Amd) 109.2 Schedule of permit fees. Each municipality shall establish a schedule of fees for construction document review, building permit, certificate of approval and certificate of occupanc schedule of adopted fees shall be posted in the building department for public view. (Del) 109.4 Work commencing before permit issuance. Delete without substitution. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) TABLE P2605.1 PIPING SUPPORT PIPING MATERIAL MAXIMUM HORIZONTAL SPACING (feet) MA VER SPACI ABS pipe - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 1010.1.1.2 Bed and breakfast establishments. Doors within and accessing Group R-1 bed breakfast establishments shall have a minimum clear width of 28 inches (711 mm). Doors within accessing bathrooms shall have a minimum clear width of 24 inches (610 mm). (Amd) 1010.1.2.1 Direction of swing. Side-hinged swinging doors, pivoted doors and bala doors shall swing in the direction of egress travel where serving a room or area containing an occupant of 50 or more persons, an exit enclosure (unless the door serves an individual living unit that opens dir into an exit enclosure) or a Group H occupancy. (Add) 1010.2.1.1 Bathroom doors. In Group R-4 occupancies, Group I-2 child care facilities and G I-4 day care facilities, bathroom doors that latch in the closed position shall be openable from insid bathroom and shall be capable of being unlocked from the ingress side. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Del) CHAPTER 43 – REMOTE-CONTROL, SIGNALING AND POWER-LIMITED CIRCU Delete chapter in its entirety. CHAPTER 44 – REFERENCED STANDARDS (Amd) ASME American Society of Mechanical Engineers Two Park Avenue New York, NY 10016 CSA CSA Group - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Swimming Pool and Spa Code Page - This page is intentionally left blank - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Energy Conservation Code Page (Amd) C402.5 Air leakage – thermal envelope. New construction building thermal envelopes shall tested in accordance with Section C402.5.2 or C402.5.3. Additions, alterations, and repairs to existin building thermal envelopes shall comply with Sections C402.5.1 through Section C402.5.11.1 or the building shall be tested in accordance with Section C402.5.2 or C402.5.3. Where compliance is base such testing, the building shall also comply with Sections C402.5.7, C402.5.8 and C402.5.9. IECC – RESIDENTIAL PROVISIONS CHAPTER 1 [RE] – SCOPE AND ADMINISTRATION (Amd) R101.1 Title. The 2021 International Energy Conservation Code as amended in this section be known as the 2021 International Energy Conservation Code portion of the 2022 Connecticut Building Code, hereinafter referred to as “the code” or “this code”. (Amd) R101.5 Compliance. Residential buildings shall meet the provisions of IECC – Reside Provisions. Commercial buildings shall meet the provisions of IECC – Commercial Provisions. Exception: Temporary structures are exempt from the requirements of this code. (Amd) R101.5.1 Compliance materials. The code official shall be permitted to approve specific com software, worksheets, compliance manuals and other similar materials that meet the intent of this cod - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 1022.3 Group M occupancies. In mercantile occupancies other than bulk merchandising buildings, if the only means of customer entrance is through one exterior wall of a building, one-half o required egress width from the street floor shall be located in such wall. For the purpose of this sec bulk merchandising retail building is defined as a building exceeding 12,000 square feet (1115 m²) in in which the sales area includes the storage of combustible materials on pallets, in solid piles or in rac excess of 12 feet (3658 mm) in storage height. (Add) 1028.4.1 Remoteness. Where two or more doors leading to exit discharge are required, a mini of two such doors shall be placed a distance apart equal to not less than one-third of the length o maximum overall diagonal dimension of the building served, measured in a straight line between d Additional doors leading to exit discharge shall be arranged a reasonable distance apart so that if becomes blocked, the others will be available. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2020 NFPA 70 National Electrical Code Page - CHAPTER 2 – WIRING AND PROTECTION (Amd) 210.8 Ground-Fault Circuit-Interrupter Protection for Personnel. (F) as follows: (Amd) (F) Outdoor Outlets. All outdoor outlets for dwellings, other than those covered in 210.8 (A Exception to (3), that are supplied by single-phase branch circuits rated 150 volts to ground or les amperes or less, shall have ground-fault circuit-interrupter protection for personnel. Exception No. 1: Ground-fault circuit-interrupter protection shall not be required on lighting outlets than those covered in 210.8(C). Exception No. 2: Ground-fault circuit-interrupter protection shall not be required for mini-split heating/ventilating/air-conditioning (HVAC) equipment and other HVAC units employing p conversion equipment as a means to control compressor speed. (Amd) 230.46 Spliced and Tapped Conductors. Service-entrance conductors shall be permitted to spliced or tapped in accordance with 110.14, 300.5(E), 300.13, and 300.15. Power distribution blocks pressure connectors, and devices for splices and taps shall be listed. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to ICC/ANSI A117.1 - 2017 Page (Amd) 502.4.1 Location. Access aisles (cross hatch) shall adjoin an accessible route. Two parking sp shall be permitted to share a common access aisle. If a car and a van space share a common access that aisle shall be 96 inches minimum in width. Access aisles shall not overlap with the vehicular Parking spaces shall be permitted to have access aisles placed on either side of the car or van parking s Van parking spaces that are angled shall have access aisles located on the passenger side of the par space. (Amd) 502.4.2 Width. Access aisles (cross hatch) serving car parking spaces shall be 60 inches (1525 minimum in width. Access aisles serving van parking spaces shall be 96 inches (2440 mm) minimu width. (Amd) 502.6 Vertical clearance. Vertical clearance for accessible van parking spaces shall b accordance with Sections 1106.6 and 1106.6.1.1 of the 2021 International Building Code portion o - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 310.4 Residential Group R-3. Residential Group R-3 occupancies where the occupant primarily permanent in nature and not classified as Group R-1, R-2, R-4 or I, including: Buildings that do not contain more than two dwelling units, with not more than six lodgers or boa per dwelling unit Care facilities that provide accommodations for five or fewer persons receiving care Congregate living facilities (nontransient) with six or fewer occupants, where personal care ser are not provided Boarding houses (nontransient) Convents Dormitories Fraternities and sororities Monasteries Congregate living facilities (transient) with six or fewer occupants where personal care service not provided Boarding houses (transient) with six or fewer occupants where personal care services are not pro (Del) 310.4.1 Care facilities within a dwelling unit. Delete section. (Del) 310.4.2 Lodging houses. Delete section. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Swimming Pool and Spa Code Page - (Amd) 304.2 Determination of impacts based on location. Pools and spas that are located in flood h areas established by the International Building Code or the International Residential Code including ab ground pools, on-ground pools and in-ground pools that involve placement of fill, shall comply with Se - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 107.7.1 Requirements for proposed structures or additions that exceed the threshold li Pursuant to section 29-276b of the Connecticut General Statutes, if a proposed structure or addition t existing structure will exceed any threshold limit set forth in Section 107.7 of this code, the building off of the municipality in which the structure or addition will be located shall require that an indepen structural engineering consultant review the structural plans and design specifications of the structu addition to be constructed to determine compliance with the requirements of this code to the e necessary to assure the stability and integrity of the primary structural support systems of such structu addition. Any modifications of approved structural plans or design specifications shall require re structural plans, revised design specifications, supplementary structural sketches and/or shop drawin the extent necessary to determine compliance with the requirements of this code and shall be reviewe such consultant. Any deferred submittals that relate to the primary structural support systems sha reviewed by such consultant. Any fees relative to such review requirements shall be paid by the own the proposed building project. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2020 NFPA 70 National Electrical Code Page - (Amd) 701.7 Signs. Amend (A) as follows: (Amd) (A) Mandated standby. A sign shall be placed at the service entrance, at the meter location, a any equipment up to the service entrance-equipment, indicating type and location of on-site legally req standby power sources. Exception: A sign shall not be required for individual unit equipment as specified in 701.12(J). (Amd) 702.7 Signs. Amend (A) as follows: (Amd) (A) Standby. A sign shall be placed at the service-entrance equipment, at the meter location, on any equipment up to the service-entrance equipment for all installations that indicates the type location of on-site optional standby power sources. For one- and two-family dwelling units, a sign s be placed at the disconnecting means required in 230.85 that indicates the location of each permane installed on-site optional standby power source disconnect or means to shut down the prime move required in 445.18(D). (Amd) 725.121 Power Sources for Class 2 and Class 3 Circuits. Amend (C) as follows: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Swimming Pool and Spa Code Page - (Add) 323.4 Pool alarm. Pursuant to section 29-265a of the Connecticut General Statutes, no buil permit shall be issued for the construction or substantial alteration of a residential swimming pool residence occupied by, or being built for, one or more families unless a pool alarm is installed wit swimming pool. As used in this section, “pool alarm” means a device that emits a sound of at lea decibels when a person or an object weighing 15 pounds (6.8 kg) or more enters the water in a swim pool. Exception: Hot tubs and portable spas shall be exempt from this requirement. (Del) SECTION 324 EQUIPMENT ROOMS. Delete section in its entirety. (Del) SECTION 325 INDOOR AIR QUALITY. Delete section in its entirety. (Del) CHAPTER 4 – PUBLIC SWIMMING POOLS. Delete chapter in its entirety. (Del) CHAPTER 5 – PUBLIC SPAS AND PUBLIC EXCERCISE SPAS. Delete chapter in its enti (Del) CHAPTER 6 – AQUATIC RECREATIONAL FACILITIES. Delete chapter in its entirety. (Del) APPENDIX A – BOARD OF APPEALS. Delete appendix in its entirety. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Plumbing Code Page For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. The maximum horizontal spacing of cast-iron pipe hangers shall be increased to 10 feet wher foot lengths of pipe are installed. b. For sizes 2 inches and smaller, a guide shall be installed midway between required vertical sup Such guides shall prevent pipe movement in a direction perpendicular to the axis of the pipe. c. The maximum horizontal spacing of PP or PP-RCT pipe hangers shall be increase manufacturer’s installation requirements based on maximum operating temperatures design. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) SECTION 2703 LIGHT POLLUTION CONTROLS (Add) 2703.1 Light pollution controls. When the power for exterior lighting is supplied through the en service to the building, luminaires used for exterior lighting shall be full cutoff luminaires. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - CHAPTER 21 – HYDRONIC PIPING (Amd) TABLE M2101.9 HANGER SPACING INTERVALS PIPING MATERIAL MAXIMUM HORIZONTAL SPACING (feet) M VE SPA ABS - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Pag (Add) 101.4.9 Oil-burning equipment, piping and storage. In addition to the requirements of this c the installation of oil burners, equipment, and appliances used in conjunction therewith, including ta piping, pumps, control devices and accessories, shall comply with NFPA 31 as adopted in the Connecticut State Fire Safety Code and the 2022 Connecticut State Fire Prevention Code. (Amd) 102.6 Existing structures. The legal use and occupancy of any building or structure existing o date of adoption of this code shall be permitted to continue without change, except as otherwise specifi provided in this code, the 2021 International Existing Building Code portion of the 2022 Connecticut Building Code or the 2022 Connecticut State Fire Safety Code. (Amd) 102.6.1 Buildings not previously occupied. A building or portion of a building that has not previously occupied or used for its intended purpose in accordance with the laws in existence at the ti its completion shall be permitted to comply with the provisions of the laws in existence at the time original permit unless such permit has expired. Subsequent permits shall comply with the Internati Building Code or International Residential Code, as applicable, for new construction. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Existing Building Code Page AMENDMENTS TO THE 2021 INTERNATIONAL EXISTING BUILDING CODE CHAPTER 1 – SCOPE AND ADMINISTRATION (Amd) 101.1 Title. The 2021 International Existing Building Code shall be known as the 2021 Internati Existing Building Code portion of the 2022 Connecticut State Building Code, hereinafter referred to as code” or “this code”. (Amd) 101.4.2 Buildings previously occupied. The legal use and occupancy of any building existin the date of adoption of this code shall be permitted to continue without change, except as specifi provided in this code or in the 2022 Connecticut State Fire Safety Code. (Add) 101.4.3 Property maintenance. The International Property Maintenance Code is not adopte the state of Connecticut. Property maintenance shall be in accordance with the requirements of this and the applicable provisions of the 2022 Connecticut State Fire Safety Code and 2022 Connecticut Fire Prevention Code. References to the International Property Maintenance Code found within the of the model document shall be considered null and void. (Amd) 101.6 Appendices. The provisions of Appendix A shall be incorporated into the requiremen this code. (Del) 101.7 Corrections of violations of other codes. Delete in its entirety and replace with the follo - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Existing Building Code Page (Add) 304.1.1 Snow loads. Where the intended alteration requires a permit for reroofing, any exi structural elements supporting snow loads shall be replaced or altered as needed to carry the design loads, including snow drift effects, as required by the International Building Code for new structures. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - CHAPTER 29 – WATER SUPPLY AND DISTRIBUTION (Add) P2902.5.3.1 Automatic lawn sprinkler system sensor device. Pursuant to section 29-265b o Connecticut General Statutes, an automatic lawn sprinkler system shall be equipped with a rain sens switch that will automatically override the irrigation cycle when adequate rainfall has occurred. CHAPTER 30 – SANITARY DRAINAGE (Del) Section P3009.1 through P3009.11. Delete sections, subsections and tables and replace with th following: (Add) P3009.1 General. Subsurface landscape irrigation systems shall comply with the Public Health of the state of Connecticut adopted pursuant to section 19a-36 of the Connecticut General Statutes. CHAPTER 31 – VENTS (Amd) P3103.1.1 Roof extension. Open vent pipes that extend through a roof that do not meet the conditions of Section P3103.1.2 or P3103.1.3 shall terminate not less than 12 inches (305 mm) above roof. (Amd) P3103.1.2 Roof used for other than weather protection. Where a roof is to be used for any purpose other than weather protection, open vent pipes shall terminate not less than 7 feet (2134 mm) above the roof. (Del) P3103.2 Frost closure. Delete without substitution. (Del) CHAPTER 34 – GENERAL REQUIREMENTS. Delete chapter in its entirety and replace the following: (Add) CHAPTER 34 – ELECTRICAL - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Plumbing Code Page (Amd) 105.1 General. The following requirements apply to the approval of materials, methods equipment as satisfying the requirements of this code. Modifications, variations or exemptions fro approval of alternative compliance with the 2022 Connecticut State Building Code requirements ma requested in accordance with Section 104.10 of the 2021 International Building Code portion of the Connecticut State Building Code. (Amd) 106.1 When required. Any owner or owner’s authorized agent who intends to construct, enl alter, repair, move, demolish or change the occupancy of a building or structure, or to move a lot lin will affect any existing building or structure, or to erect, install, enlarge, alter, repair, remove, conv replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated b code, or to cause any such work to be performed, shall first make application to the building officia obtain the required permit. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 3103.5.5.1 Tents and membrane structures with a Risk Category IV occupancy: Tents membrane structures with a Risk Category IV occupancy shall be designed and constructed to comply Sections 1606 through 1609. (Add) 3103.5.5.2 Tents and membrane structures greater than one story. Tents and mem structures exceeding one story shall be designed and constructed to comply with Sections 1606 thr - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) 111.7 Prefabricated assemblies. A certificate of approval by an approved agency shall be furni with every prefabricated assembly, including modular housing, except where all elements of the asse are readily accessible for inspection at the site. Placement of prefabricated assemblies and the connect to public utilities and private water and septic systems at the building site, as well as any site-bui installed components or equipment, shall be inspected by the building official to determine compli with this code. A final inspection shall be provided in accordance with Section 110.3.10. (Del) SECTION 113 - BOARD OF APPEALS. Delete this section in its entirety and replace wit following: (Add) SECTION 113 – MEANS OF APPEAL - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/2022 Amendments to the 2021 International Building Code Page - 64 Municipality Basic Design Wind Speeds, V (mph) Allowable Stress Design Wind Speeds, Vasd (mph) Ground Snow Load pg (psf) MCE Ground Accelerations Wind-Borne Debris Region1 Hurricane- Prone Region Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV SS (g) S1 (g) Risk Cat. III Occup. I-2 Risk Cat. IV Cornwall - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/2022 Amendments to the 2021 International Building Code Page - 67 Municipality Basic Design Wind Speeds, V (mph) Allowable Stress Design Wind Speeds, Vasd (mph) Ground Snow Load pg (psf) MCE Ground Accelerations Wind-Borne Debris Region1 Hurricane- Prone Region Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV Risk Cat. I Risk Cat. II Risk Cat. III Risk Cat. IV SS (g) S1 (g) Risk Cat. III Occup. I-2 Risk Cat. IV Sherman - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) LODGING HOUSE. A building that does not qualify as a one- or two-family dwelling un accordance with Section 101.2 or an R-1 Bed and Breakfast Establishment, and that contains onl owner’s dwelling unit and guestrooms without permanent provisions for cooking, with a total buil occupant load of not more than 16 persons. (Add) METAL BUILDING SYSTEM. An integrated set of components and assemblies, including not limited to, frames that are built-up structural steel members, secondary members that are cold-for steel or steel joists, and cladding components, specifically designed to support and transfer loads provide a complete or partial building shell. (Add) PLANS AND SPECIFICATIONS. See construction documents. (Amd) REGISTERED DESIGN PROFESSIONAL. An individual who is registered or licensed b Department of Consumer Protection pursuant to chapter 390, 391, 396 or 396a of the Connecticut Ge Statutes to practice the individual’s respective design profession and acting within the scope of his o license and practice discipline. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - CHAPTER 9 – ROOF ASSEMBLIES (Amd) R905.1.1 Underlayment Underlayment for asphalt shingles, clay and concrete tile, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles, wood shakes, me roof panels and photovoltaic shingles shall conform to the applicable standards listed in this chapter. Underlayment materials required to comply with ASTM D226, D1970, D4869 and D6757 shall bear label indicating compliance to the standard designation and, if applicable, type classification indicate Table R905.1.1(1). A minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitu membrane complying with ASTM D1970, installed in accordance with the manufacturer’s instruction for the deck material, shall be applied over all joints in the roof decking. Underlayment shall be appli over the entire roof and over the 4-inch-wide (102 mm) membrane strips and shall be applied in accordance with Table R905.1.1(2). Underlayment shall be attached in accordance with Table R905.1.1(3). Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) R302.3 Two-family dwellings. Dwelling units in two-family dwellings shall be separated from other and from common spaces serving both dwelling units by wall or floor-ceiling assemblies havin less than a 1-hour fire-resistance rating when tested in accordance with ASTM E119, UL 263 or Se - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 1704.2.5.1 Fabricator approval. Special inspections during fabrication shall be permitted t reduced or eliminated when approved by the registered design professional in responsible charge the work is done on the premises of a fabricator registered and approved to perform such work wit special inspection. Approval shall be based upon review of the fabricator’s written procedures and qu control manuals that provide a basis for control of materials and workmanship, with periodic auditi fabrication and quality control practices by an approved special inspection agency. Approved fabric shall include: - pdf_text
2022 2022 Connecticut State Fire Prevention Code. These requirements apply to liquid petroleum sto systems, gas piping systems extending from the point of delivery to the inlet connections of applia the installation and operation of residential and commercial gas appliances and related accessori covered by this code. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) TABLE 1705.2.5 REQUIRED SPECIAL INSPECTIONS OF COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION a. Inspections of holes to be performed after electrical, mechanical and plumbing rough-in inspections. b. Includes wood structural panels, steel sheet panels and gypsum board panels. (Add) 1705.2.6 Metal building systems. Special inspections of metal building systems shall be performed in accordance with Sections 1705.2.1, 1705.2.2, 1705.2.3 and 1705.2.5, and in accordance with Table 1705.2.6. The approved agency shall perform an inspection of the erected metal building system to verify compliance with the approved metal building system construction documents. (Add) TABLE 1705.2.6 REQUIRED SPECIAL INSPECTIONS OF METAL BUILDING SYSTEMS - pdf_text
2022 2022 CONNECTICUT STATE BUILDING CODE Introduction and adopted model codes - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 907.1.1 Construction documents. Construction documents for fire alarm systems shall b sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail t will conform to the provisions of this code and the 2022 Connecticut State Fire Safety Code, as determ by the code official. (Del) 907.2.7.1 Occupant notification. Delete section. (Amd) 907.2.8.2 Automatic smoke detection system. An automatic smoke detection system that acti the occupant notification system in accordance with Section 907.5 shall be installed throughout all int corridors serving sleeping units. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. Weathering may require a higher strength concrete or grade of masonry than necessary to sa the structural requirements of this code. b. Wind exposure category shall be determined on a site-specific basis in accordance with Se R301.2.1.4. (Del) FIGURE R301.2(1) WEATHERING PROBABILITY MAP FOR CONCRETEa,b. Delete without substitution. (Del) FIGURE R301.2(2) ULTIMATE DESIGN WIND SPEEDS. Delete without substitution. (Del) FIGURE R301.2(3) GROUND SNOW LOADS, Pg FOR THE UNITED STATES (lb/ft2). Delete without substitution. (Del) FIGURE R301.2(4) GROUND SNOW LOADS, Pg FOR THE UNITED STATES (lb/ft2). Delete without substitution. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Add) SECTION 429 – GROUP E (Add) 429.1 Proximity to the level of exit discharge. Proximity to the level of exit discharge sha provided in accordance with Sections 429.1.1 and 429.1.2. For the purpose of this section, “nor occupied” includes such spaces as libraries, cafeterias, gymnasiums and multipurpose rooms, but doe include administrative offices, healthcare rooms or special one-on-one rooms. (Add) 429.1.1 Preschool, kindergarten and first grade. Rooms normally occupied by presc kindergarten or first-grade students shall be located on a level of exit discharge. Exception: Rooms located on levels other than a level of exit discharge shall be permitted t normally occupied by preschool, kindergarten or first-grade students where such rooms are pro with an independent stairway or ramp directly from the room dedicated for use by the presc kindergarten or first-grade students. (Add) 429.1.2 Second grade. Rooms normally occupied by second-grade students shall be locate more than one story above a level of exit discharge. Exception: Rooms located on levels other than one story above a level of exit discharge sha permitted to be normally occupied by second-grade students where such rooms are provided wit independent stairway or ramp from the room dedicated for use by the second-grade students. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - unless that person is the owner of the building. Such officer or employee shall not engage in any work conflicts with official duties or with the interests of the agency. (Amd) R104.1 General. The building official is hereby authorized and directed to enforce the provi of this code. The building official shall have the authority to adopt policies and procedures in order to cl the application of its provisions. Such policies and procedures shall be in compliance with the inten purpose of this code. Such policies and procedures shall not have the effect of waiving require specifically provided for in this code, nor shall they have the effect of establishing requirements in e of those set forth in this code. (Add) R104.1.1 Rule-making authority. Pursuant to subsection (a) of section 29-252 of the Connec General Statutes, the State Building Inspector and the Codes and Standards Committee shall, jointly, the approval of the Commissioner of Administrative Services, adopt and administer the Connecticut Building Code for the purpose of regulating the design, construction and use of buildings or structur be erected and the alteration of buildings or structures already erected and make such amendments th as they, from time to time, deem necessary or desirable. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Add) R112.2.1 Qualifications. One member of the municipal board of appeals shall be appointed the general public. The other four members shall have at least 5 years of experience each in either buil design, building construction or supervision of building construction. (Add) R112.2.2 Chair. The board shall annually select one of its members to serve as chair. (Add) R112.3 Notice of meeting. Each appeal shall be heard in the municipality for which the buil official serves within 5 days, exclusive of Saturdays, Sundays and legal holidays, after the date of re of the appeal. (Add) R112.4 Determination of aggrievement. Upon receipt of an appeal from a person other tha owner or his agent, the board of appeals shall first determine whether such person has a right to appe (Add) R112.5 Appointment of a panel. Upon receipt of an appeal from an owner or his agent, or appr of an appeal by a person other than the owner or his agent, the chairman of the municipal board of ap shall appoint a panel of not less than three members of such board to hear such appeal. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) R327.1 General. The design and construction of pools and spas shall comply with the International Swimming Pool and Spa Code portion of the 2022 Connecticut State Building Code. CHAPTER 4 – FOUNDATIONS (Amd) R403.1 General. All exterior walls shall be supported on continuous solid or fully grouted mas or concrete footings, crushed stone footings, wood foundations or other approved structural systems shall be of sufficient design to accommodate all loads according to Section R301 and to transmi resulting loads to the soil within the limitations as determined from the character of the soil. Footings be supported on undisturbed natural soils or engineered fill. Concrete footings shall be designed constructed in accordance with the provisions of Section R403 or in accordance with ACI 332. Exception: Freestanding accessory structures with an area of 600 square feet (56 m2) or less a eave height of 10 feet (3048 mm) or less. Footings and freestanding accessory structures as exempted above shall be supported on undistu natural soils or engineered fill and shall be anchored to resist wind-induced uplift and overturnin (Del) 403.1.2 Continuous footing in Seismic Design Categories D0, D1 and D2. Delete section. (Del) 403.1.3 Footing and stem wall reinforcing in Seismic Design Categories D0, D1 and D2. D section. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Swimming Pool and Spa Code Page - (Del) SECTION 109 SERVICE UTILITIES. Delete in its entirety and refer to Section 111 of the International Building Code portion or Section R110 of the 2021 International Residential Code por as applicable, of the 2022 Connecticut State Building Code – Certificate of Occupancy. (Del) SECTION 110 INSPECTIONS. Delete in its entirety and refer to Section 110 of the International Building Code portion or Section R109 of the 2021 International Residential Code por as applicable, of the 2022 Connecticut State Building Code – Inspections. (Del) SECTION 111 – MEANS OF APPEALS. Delete in its entirety and refer to Section 113 of the International Building Code portion or Section R112 of the 2021 International Residential Code por as applicable, of the 2022 Connecticut State Building Code – Means of Appeal. (Del) SECTION 112 – BOARD OF APPEALS. Delete in its entirety. (Del) SECTION 113 - VIOLATIONS. Delete in its entirety and refer to Section 114 of the International Building Code portion or Section R113 of the 2021 International Residential Code por as applicable, of the 2022 Connecticut State Building Code – Violations. (Del) SECTION 114 – STOP WORK ORDERS. Delete in its entirety and refer to Section 115 o - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page where: w = width of tent perpendicular to the ridge line (feet) s = tent post spacing parallel to the ridge (feet) x = tent exposure factor (1.00 if tent is located in wind Exposure Exposure C as defined in Section 1609.4.3; 1.20 if tent is located in Exposure D) b. For ballast systems where the tent poles and ballast are not conn using a common base plate, the weight of the ballast provided at eac pole shall be not less than the following: For each pole perpendicular to the ridge: Pball = 6.5wsx (pounds) For each pole on a hip end: Pball = 3.25wsx (pounds) (Add) 3103.5.6 Means of egress. Means of egress for temporary tents and membrane structures shall accordance with Section 3103.12 of the International Fire Code. (Add) 3103.5.6.1 Means of egress illumination. Means of egress shall be illuminated with light havi intensity of not less than 1 foot-candle (11 lux) at floor level while the structure is occupied. Fix required for means of egress illumination shall be supplied from a separate circuit or source of power. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Energy Conservation Code Page - CHAPTER 4 [RE] – RESIDENTIAL ENERGY EFFICIENCY (Amd) R401.2.5 Additional energy efficiency. This section establishes additional requirements appli to all compliance approaches to achieve additional energy efficiency. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Mechanical Code Page (Del) SECTION 103 – CODE COMPLIANCE AGENCY. Delete Section 103 in its entirety and re to Section 103 of the 2021 International Building Code portion of the 2022 Connecticut State Buildin Code – Code Compliance Agency. (Del) SECTION 104 – DUTIES AND POWERS OF CODE OFFICIAL. Delete in its entirety and to Section 104 of the 2021 International Building Code portion of the 2022 Connecticut State Bui Code – Duties and Powers of Building Official. (Amd) 105.1 General. The following requirements apply to the approval of materials, methods equipment as satisfying the requirements of this code. Modifications, variations or exemptions fro approval of alternative compliance with the 2022 Connecticut State Building Code requirements ma requested in accordance with Section 104.10 of the 2021 International Building Code portion of the Connecticut State Building Code. - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Plumbing Code Page the Public Health Code adopted pursuant to section 19a-36 of the Connecticut General Statutes. G interceptors that serve plumbing systems connected via a sanitary sewer to a publicly owned treat works shall comply with the Department of Energy and Environmental Protection’s General Permit fo Discharge of Wastewater Associated with Food Preparation Establishments. CHAPTER 11 – STORM DRAINAGE (Amd) 1106.1 General. The size of the components of the primary drainage system, including vert conductors and leaders, building storm drains, building storm sewers and any horizontal branches of s drains or sewers shall be based on the 100-year/1-hour duration rainfall rate and shall be 3.0 inches. size of the components for the secondary (emergency overflow) roof drainage system and scuppers s be based on twice the 100-year/1-hour duration rainfall rate and shall be 6.0 inches. (Del) FIGURES 1106.1(1) through (5) 100-YEAR, 1-HOUR RAINFALL (INCHES). Delete figu - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: 10/01/ Amendments to the 2021 International Building Code Page (Amd) 903.2.11 Specific building areas and hazards. In all occupancies other than Group U, an auto sprinkler system shall be installed for building design or hazards in the locations set forth in Sect - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2020 NFPA 70 National Electrical Code Page - AMENDMENTS TO THE 2020 NFPA 70, NATIONAL ELECTRICAL CODE ARTICLE 90 – INTRODUCTION (Amd) 90.2 Scope. (A) Covered. This code covers the installation of electrical conductors, equipment and raceways; sign and communications conductors, equipment and raceways; and optical fiber cables and raceways fo following: (1) Public and private premises, including: a. buildings and structures; b. utility connections, additions and alterations to mobile homes; c. utility connections to recreational vehicles; and d. floating buildings. (2) Yards, lots, parking lots, carnivals and industrial substations. (3) Installations of conductors and equipment that connect to the supply of electricity. (4) Installations used by the electric utility, such as office buildings, warehouses, garages, machine s and recreational buildings that are not an integral part of a generating plant, substation or control cent (5) Installations supplying shore power to ships and watercraft in marinas and boatyards, inclu monitoring of leakage current. (6) Installations used to export electric power from vehicles to premises wiring or for bidirectional cu flow. (B) Not covered. This code does not cover the following: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Table of Contents TABLE OF CONTENTS - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2021 International Residential Code Page - (Amd) R313.1 Townhouse automatic fire sprinkler systems. When an automatic residential fire spri system is to be installed in townhouses, it shall be designed and installed in accordance with Section P or NFPA 13D. (Del) R313.1.1 Design and installation. Delete section. (Amd) R313.2 One- and two-family dwellings automatic fire systems. When an automatic fire spri system is to be installed in one- and two-family dwellings, it shall be designed and installed in accord with Section P2904 or NFPA 13D. (Del) R313.2.1 Design and installation. Delete section. (Amd) R314.2.2 Alterations, repairs and additions. When alterations, repairs or additions requir permit occur, or when one or more sleeping rooms are added or created in existing dwellings, the e dwelling unit shall be provided with smoke alarms located as required for new dwellings. Exceptions: - pdf_text
2022 2022 Connecticut State Building Code (w/ Errata #1) ED: October 1, Amendments to the 2020 NFPA 70 National Electrical Code Page - (2) Engineered wood products. Cuts, notches and holes bored in trusses, structural composite lu structural glue-laminated members or I-joists are prohibited except where permitted by the manufactu recommendations or where the effects of such alterations are specifically considered in the design o member by a registered design professional. (3) Studs. Any stud in an exterior wall or interior bearing partition may be cut or notched to a dept exceeding 25 percent of its width. Studs in nonbearing interior partitions may be notched to a depth n exceed 40 percent of a single stud width. Any stud may be bored or drilled, provided that the diamet the resulting hole is no greater than 40 percent of the stud width, the edge of the hole is no closer tha inch to the edge of the stud and the hole is not located in the same section as a cut or notch. Exception No. 1: A stud may be bored or drilled to a diameter not exceeding 60 per cent of its w provided that such studs located in exterior walls or interior bearing partitions are doubled and not than two successive studs are bored. Exception No. 2: Approved stud shoes may be used when installed in accordance with the manufactu recommendations. - pdf_text
2022 (cont. 2) (Add) R109.1.7 Posting of required inspections. The building official shall compile a schedul required inspections and shall post the schedule in the building department for public view. (Add) R109.5 Notification of inspection results. Notification as to passage or failure, in whole or in of any required inspection shall be made in writing by the building official or his duly author representative and shall be left at the job site or delivered to the permit holder. It shall be the duty o permit holder to ascertain the results of required inspections. (Amd) R110.1 Use and occupancy. Pursuant to subsection (a) of section 29-265 of the Connec General Statutes, no building or structure erected or altered in any municipality after October 1, 1970, be occupied or used, in whole or in part, until a certificate of occupancy has been issued by the buil official, certifying that such building, structure or work performed pursuant to the building pe substantially complies with the provisions of this code. Nothing in the code shall require the rem alteration or abandonment of, or prevent the continuance of the use and occupancy of, any single-fa dwelling but within six years of the date of occupancy of such dwelling after substantial completio construction of, alteration to or addition to such dwelling, or of a building lawfully existing on Octob - pdf_text
2022 (cont. 2) (Add) AF105.6.1 Conduit for future radon fan. A ¾-inch (19 mm) electrical compliant conduit fro basement or room or space where the electrical panel is located to the attic shall be installed d construction. This conduit is intended to and dedicated for accommodating electrical wiring should a r mitigation fan be installed. The conduit shall be capped in both the basement and in the attic. The co shall be labeled at the top and bottom and specifically state: “Reserved for a Potential Radon Redu Mechanical System.” (Add) AF105.6.2 Circuit for future radon fan. To provide for future installation of a radon fa electrical circuit terminated in an approved box shall be installed during construction in the antici location of the radon fans. (Add) AF105.7 Accessible clear space. An accessible clear space 22 inches (559 mm) in diameter feet (914 mm) in height adjacent to the vent pipe shall be provided in the attic or at an acceptable loc of a potential radon fan. - pdf_text
2022 (cont. 2) (Amd) R104.6 Right of entry. Pursuant to subsection (d) of section 29-261 of the Connecticut Ge Statutes, the building official or his assistant shall have the right of entry to such buildings or struct except single-family residences, for the proper performance of his duties between the hours of 9 a.m. - pdf_text
2022 (cont. 2) (Add) 101.7 Connecticut State Fire Safety Code abatement. Where conflicts exist betwee requirements of this code and the requirements of a 2022 Connecticut State Fire Safety Code abate order issued in writing by the local fire marshal with respect to an existing building, the requiremen that portion of the 2022 Connecticut State Fire Safety Code that regulates existing buildings shall precedence. Exceptions: - pdf_text
2022 (cont. 2) (Add) 429.2 Subdivision of building spaces. Group E occupancies shall be subdivided into compartm by smoke barriers complying with Section 709 where one or both of the following conditions exist: - pdf_text
2022 (cont. 2) (Amd) 725.121 (C) Marking. The power sources for limited power circuits in 725.121(A)(3), li power circuits for listed audio/video equipment, listed information technology equipment, l communications equipment, and listed industrial equipment in 725.121(A)(4) shall have a label indic the maximum voltage and rated current output per conductor for each connection point on the power so Where multiple connection points have the same rating, a single label shall be permitted to be used. labeling requirement shall apply to equipment with a rated current per conductor 0.3 amperes or great - pdf_text
2022 (cont. 2) (Add) 3103.5.6.2 Maintenance of means of egress. The required width of exits, aisles and passage shall be maintained at all times to a public way. Guy wires, guy ropes and other support members shal cross a means of egress at a height of less than 8 feet (2438 mm). The surface of means of egress sha maintained in an approved manner. (Add) 3103.5.7 Flame propagation performance testing and certification. Before a permit is gra the owner or the owner’s agent shall file with the code official a certificate provided by the pr manufacturer to verify that the materials have been tested and certified by an approved testing labora The certificate shall indicate that the floor coverings, tents, membrane structures and their appurtena which include sidewalls, drops and tarpaulins, are composed of materials meeting the flame propag performance of Test Method 2 of NFPA 701. Additionally, it shall indicate that the bunting and combus decorative materials and effects are composed of material meeting the flame propagation perform criteria of Test Method 1 or Test Method 2 of NFPA 701, as applicable. Alternatively, the materials be treated with a flame retardant in an approved manner and meet the flame propagation perform criteria of the applicable test method of NFPA 701. The certificate shall indicate compliance with the te requirements of NFPA 701, Chapter 16. The flame propagation performance criteria shall be effectiv the period specified by the permit. - pdf_text
2022 (cont. 2) (Del) SECTION C109 – STOP WORK ORDER. Delete in its entirety and refer to Section 115 o - pdf_text
2022 (cont. 2) (2) The metal structural frame of a building shall be permitted to be used as a conductor to interco electrodes that are part of the grounding electrode system, or as a grounding electrode conductor. down bolts securing the structural steel column that are connected to a concrete-encased elect complying with 250.52(A)(3) and located in the support footing shall be permitted to connect the structural frame of a building or structure to the concrete encased grounding electrode. The hold-down shall be connected to the concrete-encased electrode by welding, exothermic welding, the usual ste wires, or other approved means. (3) A rebar-type concrete-encased electrode installed in accordance with 250.52(A)(3) with an addit rebar section extended from its location within the concrete footing to an accessible location that i subject to corrosion shall be permitted for connection of grounding electrode conductors and bon jumpers in accordance with the following: a. The additional rebar section shall be continuous with the grounding electrode rebar or shall be conn to the grounding electrode rebar and connected together by the usual steel tie wires, exothermic wel welding, or other effective means. b. The rebar extension shall not be exposed to contact with the earth without corrosion protection. c. Rebar shall not be used as a conductor to interconnect the electrodes of grounding electrode syste CHAPTER 3 – WIRING METHODS AND MATERIALS (Add) 300.4.1 Drilling and notching. - pdf_text
2022 (cont. 2) (Amd) 1108.3 Sizing of secondary drains. Secondary (emergency) roof drain systems shall be size accordance with Section 1106. Scuppers shall be sized to prevent the depth of ponding water fr exceeding that for which the roof was designed as determined by Section 1101.7. Scuppers shall hav opening dimension of not less than 4 inches (102 mm) in height and have an opening width equal to circumference of the roof drain required for the area served. The flow through the primary system s not be considered when sizing the secondary roof drain system. CHAPTER 12 – SPECIAL PIPING AND STORAGE SYSTEMS (Amd) 1201.1 Scope. The provisions of this chapter shall govern the design and installation of pipin storage systems for non-flammable medical gas systems and non-medical oxygen systems. All mainten and operation of such systems shall be in accordance with the Connecticut State Fire Prevention Cod CHAPTER 14 – SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS (Del) Sections 1401 through 1403. Delete sections, subsections and tables and replace with the following: (Add) 1401.1 General. Subsurface landscape irrigation systems shall comply with the Public Health adopted pursuant to section 19a-36 of the Connecticut General Statutes. CHAPTER 15 – REFERENCED STANDARDS (Amd) NFPA National Fire Protection Association - pdf_text
2022 (cont. 2) (Amd) 1704.2 Special inspections and tests. Where application is made to the building officia construction as specified in Section 105, the owner or the owner’s authorized agent, other tha contractor, shall employ one or more approved agencies to provide special inspections and tests d construction on the types of work specified in Section 1705 and identify the approved agencies t building official. These special inspections and tests are in addition to the inspections by the building off that are identified in Section 110. Exceptions: - pdf_text
2022 (cont. 2) (Amd) 312.5 Water supply system test. Upon completion of a section of or the entire water supply sy the system, or portion completed, shall be tested and proved tight under a water pressure not less tha working pressure of the system; or, for piping systems other than plastic, by an air test of not less tha psi (344 kPa). This pressure shall be held for not less than 15 minutes. The water utilized for tests sh obtained from a potable source of supply. The required tests shall be performed in accordance with section and Section 108. Exception: For PEX piping systems, testing with a compressed gas shall be an alternati hydrostatic testing where compressed air or other gas pressure testing is specifically authoriz the manufacturer’s instructions for the PEX pipe and fittings products installed at the tim system is being tested, and compressed air or other gas testing is not otherwise prohibite applicable codes, laws or regulations outside of this code. (Del) 312.10.1 Inspections. Delete section. - pdf_text
2022 (cont. 2) (Add) R112.6 Rendering of decisions. The panel shall, upon majority vote of its members, affirm, m or reverse the decision of the building official in a written decision upon the appeal and file such deci with the building official from whom such appeal has been taken not later than 5 days, exclusiv Saturdays, Sundays and legal holidays, following the day of the hearing thereon. A copy of the deci shall be mailed, prior to such filing, to the party taking the appeal. (Add) R112.7 Appeal to the Codes and Standards Committee. Any person aggrieved by the decisi a municipal board of appeals may appeal to the Codes and Standards Committee within 14 days afte filing of the decision with the building official in accordance with the provisions of subsection (b) of se - pdf_text
2022 (cont. 2) (Add) SPA, EXERCISE (Also known as a swim spa). Variants of a spa in which the design construction includes specific features and equipment to produce a water flow intended to a recreational physical activity including, but not limited to, swimming in place. Exercise spas can inc peripheral jetted seats intended for water therapy, heater, circulation and filtration system, or can separate distinct portion of a combination spa/exercise spa and can have separate controls. These spa of a design and size such that they have an unobstructed volume of water large enough to allow the Percentile Man as specified in APSP 16 to swim or exercise in place. (Amd) SPECIAL AMUSEMENT AREA. A special amusement area is any temporary or perma building or portion thereof that is occupied for amusement, entertainment or educational purposes a arranged in a manner that: - pdf_text
2022 (cont. 2) (Amd) 104.6 Right of entry. Pursuant to subsection (d) of section 29-261 of the Connecticut Ge Statutes, the building official or his assistant shall have the right of entry to such buildings or struct except single-family residences, for the proper performance of his duties between the hours of nine and five p.m., except that in the case of an emergency, he shall have the right of entry at any time, if entry is necessary in the interest of public safety. Pursuant to section 29-393 of the Connecticut Ge Statutes, on receipt of information from the local fire marshal or from any other authentic source that building in his jurisdiction, due to lack of exit facilities, fire, deterioration, catastrophe or other cause, such condition as to be a hazard to any person or persons, the building official or his assistant immediately make an inspection. (Del) 104.10 Modifications. Delete section and subsection and replace with the following: (Add) 104.10 Modifications. Modifications, variations, or exemptions from and approval of equivale alternative compliance with the requirements of this code shall be in accordance with the provisio Sections 104.10.1 to 104.10.6, inclusive. - pdf_text
2022 (cont. 2) (Del) SECTION 113 - MEANS OF APPEALS. Delete this section in its entirety and refer to Section of the 2021 International Building Code portion of the 2022 Connecticut State Building Code – Mea Appeal. (Del) SECTION 114 BOARD OF APPEALS Delete this section in its entirety and refer to Section of the 2021 International Building Code portion of the 2022 Connecticut State Building Code – Mea Appeal. (Add) 115.2.1 Written notice. The notice of violation shall be in writing and shall be given to the o of the property involved, or to the owner’s agent or to the person doing the work. (Amd) 115.4 Violation penalties. Pursuant to section 29-254a of the Connecticut General Statutes, person who violates any provision of this code shall be fined not less than two hundred nor more than thousand dollars or imprisoned not more than six months or both. (Amd) 116.4 Failure to comply. Any person who shall continue any work after having been served a stop work order, except such work as that person is directed to perform to remove a violation or u condition, shall be liable for penalties in accordance with Section 115.4. CHAPTER 2 – DEFINITIONS (Amd) 201.3 Terms defined in other codes. Where terms are not defined in this code and are defin other portions of the 2022 Connecticut State Building Code, such terms shall have the meanings asc to them as in those portions. (Add) 202.1 Definitions. Add or amend the following definitions: - pdf_text
2022 (cont. 2) (Amd) 90.4 Enforcement. Administration of this code shall be in accordance with the provision Chapter 1 of the 2021 International Building Code portion of the 2022 Connecticut State Building C For the purposes of this code, the authority having jurisdiction for interpreting the rules and for gra the special permission contemplated in a number of rules is the State Building Inspector. Interpretat shall be requested verbally or in writing from the Office of the State Building Inspector. Special permis shall be requested in writing using the Request for Modification of the State Building Code form avail from local building departments or from the Office of the State Building Inspector, 450 Colu Boulevard, Suite 1303, Hartford CT 06103. www.portal.ct.gov/DAS. Where this Code contains requirements for a new product, construction, or material that has an effe date after the adoption date of the 2022 Connecticut State Building Code, those requirements are not of this Code. CHAPTER 1 – GENERAL ARTICLE 100 – Definitions. - pdf_text
2022 (cont. 2) (Del) SECTION 106 CONSTRUCTION DOCUMENTS. Delete in its entirety and refer to Section of the 2021 International Building Code portion or Section R106 of the 2021 International Reside Code portion, as applicable, of the 2022 Connecticut State Building Code – Construction Documents. (Del) SECTION 107 TEMPORARY STRUCTURES AND USES. Delete in its entirety and ref - pdf_text
2022 (cont. 2) (Add) 407.14.2.1 Height, area and construction type. Height and area shall comply with Chapter the requirements of Chapter 6, except as provided in Section 407.14.2.1.1. (Add) 407.14.2.1.1 Type VB construction. Type VB construction is permitted for a one-story buildin more than 4,500 square feet (418 m2) in area where the unoccupied attic space is protected by auto sprinklers or provided with heat detection in the attic connected to the building fire alarm system. (Add) 407.14.2.2 Automatic fire sprinkler system. Buildings shall be equipped with a NFPA sprinkler system or an NFPA 13D sprinkler system with a 30-minute water supply. All storage, habi and occupiable rooms, as well as kitchens and closets, shall be sprinklered. Sprinkler valves sha electrically supervised and connected to the building fire alarm system. Exception: Attached unheated garages used only for storage provided it is separated from remainder of the structure by 1-hour fire-resistive construction with any openings protected b minute opening protectives. The garage shall also be provided with heat detection connected t building fire alarm system. (Add) 407.14.2.3 Exterior ramps. Exterior ramps in accordance with Section 1027 shall be permitte small Group I-2 homes. (Del) 410.2.6 Scenery. Delete section. - pdf_text
2022 (cont. 2) (1) Installations in ships, watercraft other than floating buildings, railway rolling stock, aircra automotive vehicles other than mobile homes and recreational vehicles. (2) Installations underground in mines and self-propelled mobile surface mining machinery an attendant electrical trailing cable. (3) Installations of railways for generation, transformation, transmission or distribution of power exclusively for operation of rolling stock or installations used exclusively for signaling communications purposes. (4) Installations of communications equipment under the exclusive control of communications util located outdoors or in building spaces used exclusively for such installations. (5) Installations under the exclusive control of an electric utility where such installations: a. Consist of service drops or service laterals, and associated metering; or b. Are located in legally established easements, rights-of-way or by other agreements e designated by or recognized by public service commissions, utility commissions or regulatory agencies having jurisdiction for such installations; or - pdf_text
2022 (cont. 2) (Add) C101.6 Administrative matters not provided for. Administrative matters not covered by this shall be in accordance with the provisions of Chapter 1 of the 2021 International Building Code porti the 2022 Connecticut State Building Code. (Amd) C102.1.1 Above code programs. The State Building Inspector and the Codes and Stan Committee may deem a national, state or local energy efficiency program to exceed the energy effici required by this code. Such energy efficiency programs may include, but not be limited to, the Leade in Energy and Environmental Design rating system, the Green Globes USA design program, as establi by the Green Building Initiative, the National Green Building Standard, as established by the Nat Association of Home Builders, or an equivalent rating system approved in accordance with section 29- of the Connecticut General Statutes. Buildings approved in writing by such an energy efficiency pro shall be considered in compliance with this code. The requirements identified as “mandatory” in C407.2 shall be met. - pdf_text
2022 (cont. 2) (Amd) 3401.1 General. The design and installation of electrical systems, equipment and components indoors and outdoors that are within the scope of this code, including services, power distribution systems, fixtures, appliances, devices and appurtenances shall comply with the 2020 National Electri Code (NFPA 70) portion of the 2022 Connecticut State Building Code. Chapters 34 through 43 are included for reference only. (Del) CHAPTER 35 – ELECTRICAL DEFINITIONS. Delete chapter in its entirety. (Del) CHAPTER 36 – SERVICES. Delete chapter in its entirety. (Del) CHAPTER 37 – BRANCH CIRCUIT AND FEEDER REQUIREMENTS. Delete chapter entirety. (Del) CHAPTER 38 – WIRING METHODS. Delete chapter in its entirety. (Del) CHAPTER 39 – POWER AND LIGHTING DISTRIBUTION. Delete chapter in its entirety (Del) CHAPTER 40 – DEVICES AND LUMINAIRES. Delete chapter in its entirety. (Del) CHAPTER 41 – APPLIANCE INSTALLATION. Delete chapter in its entirety. (Del) CHAPTER 42 – SWIMMING POOLS. Delete chapter in its entirety. - pdf_text
2022 (cont. 2) (Amd) AF103.12 Power source and access for future radon fan. To provide for future installation radon fan, an electrical circuit terminated in an approved box shall be installed during construction i anticipated location of the radon fans. An accessible clear space 22 inches (559 mm) in diameter by (914 mm) in height adjacent to the vent pipe shall be provided at the anticipated location of a future r fan. (Add) SECTION AF105 RADON MITIGATION PREPARATION (Add) AF105.1 Soil-gas-retarder. A continuous membrane of 6-mil (0.15 mm) polyethylene or approved equivalent material used to retard the flow of soil gases into a dwelling shall be installed u the floor slab in accordance with Section R506.2.3. - pdf_text
2022 (cont. 2) CHAPTER 5 – PRESCRIPTIVE COMPLIANCE METHOD (Amd) 503.1 General. Alterations to any building or structure shall comply with the requirements o International Building Code for new construction. Alterations shall be such that the existing buildi structure is not less complying with the provisions of the International Building Code than the exi building or structure was prior to the alteration. Exceptions: - pdf_text
2022 (cont. 2) (Amd) 230.85 Emergency Disconnects. For new one- and two-family dwelling units, all se conductors shall terminate in disconnecting means having a short-circuit current rating equal to or gr than the available fault current, installed in a readily accessible outdoor location. If more than disconnect is provided, they shall be grouped. Each disconnect shall be one of the following: (1) Service disconnects marked as follows: EMERGENCY DISCONNECT, SERVICE DISCONNECT (2) Meter disconnects installed per 230.82(3) and marked as follows: EMERGENCY DISCONNECT, METER DISCONNECT, NOT SERVICE EQUIPMENT (3) Other listed disconnect switches or circuit breakers on the supply side of each service discon that are suitable for use as service equipment and marked as follows: EMERGENCY DISCONNECT, NOT SERVICE EQUIPMENT Markings shall comply with 110.21(B). (Amd) 250.50 Grounding Electrode System. All grounding electrodes as described in 250.52( through (A)(7) that are available at each building or structure served shall be bonded together to for grounding electrode system. Where none of these grounding electrodes exist, one or more of the groun electrodes specified in 250.52(A)(4) through (A)⁠(8) shall be installed and used. Exception: Concrete-encased electrodes of existing buildings or structures shall not be required to be of the grounding electrode system where the steel reinforcing bars or rods are not accessible for use wi disturbing the concrete. - pdf_text
2022 (cont. 2) (Amd) 111.1 Use and occupancy. Pursuant to subsection (a) of section 29-265 of the Connecticut Ge Statutes, no building or structure erected or altered in any municipality after October 1, 1970, sha occupied or used, in whole or in part, until a certificate of occupancy has been issued by the buil official, certifying that such building or structure or work performed pursuant to the building pe substantially complies with the provisions of this code. Nothing in the code shall require the rem alteration or abandonment of, or prevent the continuance of the use and occupancy of, any single-fa dwelling but within six years of the date of occupancy of such dwelling after substantial completio construction of, alteration to or addition to such dwelling, or of a building lawfully existing on Octob - pdf_text
2022 (cont. 2) (c) Upon a determination by a local director of health that an automatic fire extinguishing system irrigation system, change of use, installation of fixtures or facilities in a building or other phy connection between the distribution system of a public water supply system and any other wa system creates an unreasonable risk of injury to the health or safety of persons using the wate the general public, or to any public water supply, the local director of public health may issue order requiring the immediate implementation of mitigation measures, that include, but are n limited to, the disconnection of the system. In the event that a cross connection with the publi water system is found, the owner of such system may terminate services to the premises. (Amd) 608.17 Connections to the potable water system. Connections to the potable water system conform to Sections 608.17.1 through 608.17.10 and be in accordance with the Public Health Code o state of Connecticut adopted pursuant to section 19a-36 of the Connecticut General Statutes. (Amd) 608.18 Protection of individual water supplies. An individual water supply shall be located constructed so as to be safeguarded against contamination in accordance with the Public Health Co the State of Connecticut adopted pursuant to section 19a-36 of the Connecticut General Statutes. (Del) 608.18.1 through 608.18.8. Delete subsections and referenced table. CHAPTER 7 – SANITARY DRAINAGE - pdf_text
2022 (cont. 2) (Add) 1005.2 Main Entrance – Group A. In Group A occupancies created by change of occupancy have a single main entrance, such main entrance shall also be the main exit. The main entrance/exit be of sufficient width to accommodate not less than two-thirds of the occupant load, but such width not be less than the total required width of all means of egress leading to the exit. The remaining exits be capable of providing at least one-half of the total required exit capacity. Exception: In assembly occupancies where there is no well-defined main entrance and main e where multiple main entrances and main exits are provided, exits shall be permitted to be distri around the perimeter of the building or space containing the assembly occupancy, provided the width of egress is not less than 100 per cent of the required width. (Amd) 1011.2.1 Fire sprinkler system. Where a change in occupancy classification occurs or where t is a change of occupancy within a space where there is a different fire protection system thres requirement in Chapter 9 of the International Building Code that requires an automatic fire sprinkler sy to be provided based on the new occupancy in accordance with Chapter 9 of the International Buil Code. The installation of the automatic sprinkler system shall be required throughout the building or w the area of the change of occupancy and areas of the building not separated horizontally and vertically the change of occupancy by one of the following: - pdf_text
2022 (cont. 2) (Add) 107.6 Additional requirements. Pursuant to section 29-276c of the Connecticut General Stat the plans and specifications for any proposed structure or addition classified as (1) assembly, educati institutional, high-hazard, transient residential, which includes hotels, motels, rooming or boarding ho dormitories or similar buildings, other than residential buildings designed to be occupied by one or families, without limitation as to size or number of stories; (2) business, factory and industrial, merca moderate and low-hazard storage, having three stories or more or exceeding 30,000 square feet total area; and (3) nontransient residential dwellings having more than 16 units or 24,000 square feet total area per building, shall be sealed by a licensed architect or professional engineer as defined by the stat requirements of the professional registration laws of the state of Connecticut, and acting within the s of their practice. Such architect or engineer shall be responsible for the review of shop drawings an observation of construction. In the event such architect or engineer is unable to fulfill his or her re responsibilities, an additional architect or engineer shall be retained and the local building official sha informed, in writing, of such retainer. If fabricated structural load-bearing members or assemblies are in such construction, the licensed professional engineer responsible for the design of such membe assemblies shall be responsible for the implementatio - pdf_text
2022 (cont. 2) If a structure or addition exceeds the threshold limit, the architect of record, professional engineer of re responsible for the design of the structure or addition and the general contractor shall sign a stateme professional opinion affirming that the completed construction is in substantial compliance with approved plans and design specifications. If fabricated structural load-bearing members or assemblie used in the construction, the professional engineer responsible for the design of such member assemblies shall sign a statement of professional opinion affirming that the completed fabrication substantial compliance with the approved design specifications. The building official of the municipality in which the structure or addition will be located shall sa himself that each architect, professional engineer, including each professional engineer responsible fo design of fabricated structural load-bearing members or assemblies, general contractor and subcontractor involved in the project holds a license to engage in the work or occupation for whic appropriate building permit has been issued. - pdf_text
2022 (cont. 2) (Add) R110.10 Certificate of approval. The building official shall issue a certificate of approval indic substantial compliance with the requirements of this code for all completed work that requires a buil permit but does not require a certificate of occupancy. Such work shall include, but not be limited to: fe greater than 7 feet (2134 mm) in height; retaining walls greater than 3 feet (914 mm) in height; d garages; swimming pools; basements and attics converted to habitable space; electrical, plumbing mechanical repairs or alterations. No certificate of approval shall be issued for work subject to the zo regulations of a municipality without certification in writing by the official charged with the enforce of such regulations that the work is in conformity with such regulations or is a valid nonconforming under such regulations. (Del) SECTION R112 - BOARD OF APPEALS. Delete this section in its entirety and replace wit following: (Add) SECTION R112 – MEANS OF APPEAL - pdf_text
2022 (cont. 2) (Add) 101.2.2 Gas. The International Fuel Gas Code is not adopted by the state of Connecticut. references to the International Fuel Gas Code within the body of this code shall be considered refere to requirements of NFPA 2, Hydrogen Technologies Code, NFPA 54, National Fuel Gas Code and N - pdf_text
2022 (cont. 2) (Amd) R106.1.1 Information on construction documents. Construction documents shall be drawn suitable material. Electronic media documents are permitted to be submitted where approved by building official. Construction documents shall be of sufficient clarity to indicate the location, nature extent of the work proposed and show in detail that it will conform to the provisions of this code relevant laws, ordinances, rules and regulations, as determined by the building official. When the qu or arrangement of materials is essential for conformity to this code, specific information shall be giv establish such quality or arrangement, and this code shall not be cited, or terms such as “legal,” “per c or their equivalent used as a substitute for specific information. (Add) R106.2.1 Private sewage disposal system. The site plan shall indicate the location of a priva public sewage disposal system. Private sewage disposal systems shall be designed and installe accordance with the requirements of the Public Health Code adopted under authority of section 19a- the Connecticut General Statutes. All technical and soil data required by the Public Health Code sha submitted with the site plan. Approval of such systems shall be by the local authority having jurisdic When such approval is required by the local authority having jurisdiction, written proof of such appr shall be submitted to the building official prior to issuance of a building permit. - pdf_text
2022 (cont. 2) (4) Top plates. When wiring, conduit, piping or ductwork is placed in or partly in an exterior wa interior bearing wall, necessitating cutting, drilling or notching of the top plate by more than 50 per ce its width, a galvanized metal tie of not less than 0.054 inch thick (1.37 mm) (16 ga) and 1 ½ inche mm) wide shall be fastened across and to the plate at each side of the opening with not less than eight (0.148 inch diameter) nails at each side or equivalent. The metal tie must extend a minimum of 6 in (152 mm) past the opening. Exception: When the entire side of the wall with the notch or cut is covered by wood structural sheathing. CHAPTER 4 – EQUIPMENT FOR GENERAL USE (Amd) 440.14 Location – Add exception No. 3. (Add) Exception No. 3: Where the interior section of a factory packaged split system is fed solely fro exterior section of the system and the disconnecting means for the exterior section is capable of locked in the open position, a separate disconnecting means for the interior section shall not be req within sight from that section. The provisions for locking or adding a lock to the disconnecting means remain in place with or without the lock installed. CHAPTER 5 - SPECIAL OCCUPANCIES (Amd) 517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipme Patient Care Spaces. Wiring in patient care spaces shall comply with 517.13(A) and (B). - pdf_text
2022 (cont. 2) (Add) R301.2.4.2 Structures being elevated to comply with flood regulations. Structures being elev in height to be at or above the design flood elevation with minimal alterations to the existing structure be anchored to the new foundation or the raised existing foundation with connections capable of resi the wind loads and other loads prescribed by this chapter. New foundations or raised existing foundat shall be designed and constructed in accordance with Section R322 and Chapter 4. Where the alterat to the structure include exposing the structural framing in any portion of the structure, connectors sha installed as required to transfer wind loads and other loads prescribed by this chapter through the exp portion of the structure. An existing structure shall be reinforced to comply with the structural wind loading requirements for structures when any of the following occur: - pdf_text
2022 (cont. 2) (Amd) R301.2.1 Wind design criteria. Buildings and portions thereof shall be constructed in accord with the wind provisions of this code using the ultimate design wind speed in Appendix AY. W different construction methods and structural materials are used for various portions of a buildi structure, the applicable requirements of this section for each portion shall apply. Where not other specified, the wind loads listed in Table R301.2(2) adjusted for height and exposure using Table R301 shall be used to determine design load performance requirements for wall coverings, curtain walls, coverings, exterior windows, skylights, garage doors and exterior doors. Asphalt shingles shall be desi for wind speeds in accordance with Section R905.2.4. A continuous load path shall be provided to tra the applicable uplift forces in Section R802.11.1 from the roof assembly to the foundation. (Amd) R301.2.1.1 Alternative wind design provisions. As an alternative to the requirements in Se R301.2.1, the design of buildings for wind loads may be in accordance with one or more of the follo methods: - pdf_text
2022 (cont. 2) (Add) 111.1.4 Special inspections. No certificate of occupancy shall be issued for a proposed structu addition until the building official has been provided with the final report of inspections docume completion of special inspections as required by Section 1704.2 and correction of any discrepancies n in the inspections. (Add) 111.1.5 Concrete documentation. Pursuant to section 29-265c of the Connecticut General Stat prior to the issuance of a certificate of occupancy for a new residential or commercial building for wh concrete foundation was installed on or after October 1, 2016, the applicant shall provide the buil official with written documentation of the name of the individual or entity that supplied the concrete the name of the individual or entity that installed the concrete. Copies of such documentation sha maintained in the records of the office of the building official for not less than fifty years. (Amd) 111.3 Temporary occupancy. The building official may issue a temporary certificate of occup before the completion of the entire work covered by the permit, provided such portion or portions sha occupied safely prior to full completion of the building or structure without endangering life or p welfare. Any occupancy permitted to continue during completion of the work shall be discontinued w - pdf_text
2022 (cont. 2) (Add) 101.2.1 Gas. The International Fuel Gas Code is not adopted by the state of Connecticut. references to the International Fuel Gas Code within the body of this code shall be considered refere to requirements of NFPA 2, Hydrogen Technologies Code, NFPA 54, National Fuel Gas Code and N - pdf_text
2022 (cont. 2) (Amd) 1030.2 Assembly main exit. Pursuant to section 29-381a of the Connecticut General Statutes, building, room or space used for assembly purposes and provided with a single main entrance/exit main exit shall be of sufficient width to accommodate not less than two-thirds of the occupant load such width shall not be less than the total required width of all means of egress leading to the exit. section applies to Group A occupancies that are newly constructed, have an increase in the numb occupants by addition or alteration, or are created by change of occupancy. Where the building is class as a Group A occupancy, the main exit shall front on at least one street or an unoccupied space of not than 10 feet (3048 mm) in width that adjoins a street or public way. In a building, room or space use assembly purposes where there is no well-defined main entrance/exit or where multiple entrances/exits are provided, exits shall be permitted to be distributed around the perimeter of the buil provided that the total width of egress is not less than 100 percent of the required width. (Amd) 1031.2 Where required. In addition to the means of egress required by this chapter, emerg escape and rescue openings shall be provided in the following occupancies: - pdf_text
2022 (cont. 2) (Add) 3103.5.8.4 Auxiliary power. Places of assembly for more than 200 occupants shall be furni with either a fully automatic auxiliary engine-generator set capable of powering one blower continu for 4 hours, or a supplementary blower powered by an internal combustion engine that shall be auto in operation. (Add) 3103.5.9 Operational requirements. Temporary and permanent tents and membrane struc shall comply with Sections 3103.5.9.1 through 3103.5.9.5. (Add) 3103.5.9.1 Spot lighting. Spot or effect lighting shall only be by electricity, and all combu construction located within 6 feet (1829 mm) of such equipment shall be protected with appr noncombustible insulation not less than 9¼ inches (235 mm) thick. (Add) 3103.5.9.2 Heating and cooking equipment. Heating and cooking equipment shall be in accord with Section 3104.15 of the Connecticut State Fire Safety Code. (Add) 3103.5.9.3 LP-gas. The storage, handling and use of LP-gas and LP-gas equipment shall accordance with Section 3104.16 of the Connecticut State Fire Safety Code. (Add) 3103.5.9.4 Flammable and combustible liquids. The use of flammable-fuel-fired equipment be in accordance with Section 3104.17 of the Connecticut State Fire Safety Code. - pdf_text
2022 (cont. 2) (Add) 114.2.1 Written notice. The notice of violation shall be in writing and shall be given to the o of the property involved, or to the owner’s agent or to the person doing the work. (Amd) 114.4 Violation penalties. Pursuant to section 29-254a of the Connecticut General Statutes, person who violates any provision of this code shall be fined not less than two hundred nor more than thousand dollars or imprisoned not more than six months or both. (Amd) 115.4 Failure to comply. Any person who shall continue any work in or about the structure having been served with a stop work order, except such work as that person is directed to perform to re a violation or unsafe conditions, shall be liable for penalties in accordance with Section 114.4. (Add) 116.6 Unsafe equipment. Equipment deemed unsafe by the building official or his author representative shall not be operated after the date stated in the notice unless the required repairs or cha have been made and the equipment has been approved, or unless an extension of time has been sec from the building official or his authorized representative in writing. (Add) 116.6.1 Authority to seal equipment. In the case of emergency, the building official o authorized representative may seal out of service immediately any unsafe device or equipment regul by this code. - pdf_text
2022 (cont. 2) (Add) 113.1 Appeal from decision of building official. Pursuant to subsection (b) of section 29-26 the Connecticut General Statutes, when the building official rejects or refuses to approve the mod manner of construction proposed to be followed or the materials to be used in the erection or alterati a building or structure, or when it is claimed that the provisions of the code do not apply or that an eq good or more desirable form of construction can be employed in a specific case, or when it is claimed the true intent and meaning of the code has been misconstrued or wrongly interpreted or when the buil official issues a written order under subsection (c) of section 29-261 of the Connecticut General Stat the owner of such building or structure, whether already erected or to be erected, or his authorized a may appeal in writing or by electronic mail from the decision of the building official to the municipal b of appeals. A person, other than such owner, who claims to be aggrieved by any decision of the buil official may, by himself or his authorized agent, appeal in writing or by electronic mail from the deci of the building official to the municipal board of appeals as provided by subsection (b) of section 29 of the Connecticut General Statutes. (Add) 113.1.1 Absence of municipal board of appeals. In the absence of a municipal board of app the provisions of subsection (c) of section 29-266 of the Connecticut General Statutes shall be follow - pdf_text
2022 (cont. 2) (Amd) R108.1 Referenced codes and standards. The codes and standards referenced in this code sh those listed in Chapter 6, and such codes and standards shall be considered as part of the requiremen this code to the prescribed extent of each such reference and as further regulated in Sections C108.1. C108.1.2. Any reference to an ICC code adopted as part of the 2022 Connecticut State Building Co the 2022 Connecticut State Fire Safety Code shall mean a reference to such ICC code as amended b state of Connecticut. (Del) SECTION R109 – STOP WORK ORDER. Delete in its entirety and refer to Section 115 o - pdf_text
2022 (cont. 2) (Add) 117.1 Imminent danger. When, in the opinion of the building official, there is imminent dang failure or collapse of a building or structure or any part thereof which endangers human life, or when building or structure or part thereof has fallen and human life is endangered by the occupation o building or structure, the building official is hereby authorized and empowered to order and requir occupants to vacate the same forthwith. The building official shall post, or cause to be posted, at entrance to such building or structure a notice reading as follows: “This structure is unsafe an occupancy has been prohibited by the building official.” It shall be unlawful for any person to enter premises except upon permission granted by the building official for the purposes of making the req repairs or of demolishing the premises. The posted identification shall not be defaced or removed ex by the building official or his authorized representative. (Add) 117.2 Temporary safeguards. When, in the opinion of the building official, there is immi danger to human life due to an unsafe condition, the building official shall cause the necessary work t done to render such building or structure temporarily safe, whether or not the legal procedure describ - pdf_text
2022 (cont. 2) (Del) FIGURE R403.1.3 REINFORCED CONCRETE FOOTINGS AND MASONRY CONCRETE STEM WALLS IN SDC D0, D1 AND D2. Delete figure in its entirety. (Del) 403.1.3.1 Concrete stem walls with concrete footings. Delete section. (Del) 403.1.3.2 Masonry stem walls with concrete footings. Delete section. (Del) 403.1.3.3 Slabs-on-ground with turned-down footings. Delete section. (Del) 403.1.3.4 Interior bearing and braced wall panel footings in Seismic Design Categories D and D2. Delete section. (Del) 403.1.3.5 Reinforcement. Delete section and all subsections. (Del) R403.1.3.6 Isolated concrete footings. Delete section. (Amd) R403.1.4.1 Frost protection. Except where otherwise protected from frost, foundation walls, and other permanent supports of buildings and structures shall be protected from frost by one or mo the following methods: - pdf_text
2022 (cont. 2) (Add) R101.5.2 Energy efficiency standards for products. In addition to the requirements of this the testing, certification and enforcement of efficiency standards for new products sold, offered for sa installed in Connecticut shall comply with regulations adopted pursuant to section 16a-48 of Connecticut General Statutes. (Add) R101.6 Administrative matters not provided for. Administrative matters not covered by this shall be in accordance with the provisions of Chapter 1 of the 2021 International Building Code porti the 2022 Connecticut State Building Code. (Amd) R102.1.1 Above code programs. The State Building Inspector and the Codes and Stan Committee may deem a national, state or local energy efficiency program to exceed the energy effici required by this code. Such energy efficiency program may include, but not be limited to, the Leade in Energy and Environmental Design Rating System, the Green Globes USA design program, as establi by the Green Building Initiative, the National Green Building Standard, as established by the Nat Association of Home Builders, or an equivalent rating system approved in accordance with section 29- of the Connecticut General Statutes. Buildings approved in writing by such an energy efficiency program shall be considered in compliance this code. The requirements identified as “mandatory” in Chapter 4 of this code, as applicable, shall be - pdf_text
2022 (cont. 2) (Amd) 310.5 Residential Group R-4. Residential Group R-4 occupancy shall include buildings, struct or portions thereof for more than 3 but not more than 16 occupants, excluding staff, who reside on hour basis in a supervised residential environment and receive custodial care. Buildings of Group R-4 be classified as one of the occupancy conditions specified in Section 310.5.1 or 310.5.2. The per receiving care are capable of self-preservation. This group shall include, but not be limited to, the follo Alcohol and drug centers Assisted living facilities Congregate care facilities Group homes Halfway houses Residential board and care custodial care facilities Social rehabilitation facilities Group R-4 occupancies shall meet the requirements for construction as defined for Group R-3, exce otherwise provided for in this code. CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE OCCUPANCY (Amd) 403.3.3 Secondary water supply. An automatic secondary on-site water supply having a cap not less than the hydraulically calculated sprinkler demand, including the hose stream requirement, sh provided for high-rise buildings assigned to Seismic Design Category D, E or F as determined by Se - pdf_text
2022 (cont. 2) RESIDENTIAL SWIMMING POOL (Residential Pool). A pool intended for use that is accessor residential setting and available only to the household and its guests that is capable of containing more than 24” deep. Other pools shall be considered to be public pools for purposes of this code. Type O. A nondiving residential pool. Types I–V. Residential pools suitable for the installation of diving equipment by type. - pdf_text
2022 (cont. 2) (Add) 413.5 Connection required. Floor drains shall connect to the sanitary sewer system or to an on holding tank(s) when the discharge contains petroleum-based oil, grease, sand or other harmf hazardous substances. Interceptors and separators shall be provided in accordance with Section 1003 floor drains connect to the sanitary sewer system, and shall be installed in accordance with regulat promulgated by the Department of Energy and Environmental Protection. Floor drains shall no connected to a storm sewer, a storm drainage system or a storm building drain. Floor drains shall have seals in accordance with Section 1002.4. CHAPTER 5 – WATER HEATERS (Amd) 504.6 Requirements for discharge piping. Amend item 10. as follows: - pdf_text
2022 (cont. 2) (Add) R320.1 Scope. Detached one- and two-family dwellings shall be exempt from accessi requirements. Attached multiple single-family dwellings (townhouses) shall comply with Section R for single-story townhouses and with Section R320.3 for multistory townhouses. For the purposes o section, a one-story above-grade townhouse with a finished basement shall be considered a multi townhouse. Required Type B units shall comply with ICC/ANSI A117.1, as amended. (Add) R320.2 Single-story townhouses. Where there are four or more townhouses in a single struc each single-story townhouse shall be a Type B unit. Exception: The number of Type B units shall be permitted to be reduced in accordance with Se R320.4. (Add) R320.3 Multistory townhouses. Buildings or complexes that contain 10 or more multi townhouses shall have at least 10 percent Type B units. This requirement shall be met by providi sufficient number of single-story Type B units or by providing a sufficient number of multistory townh that incorporate a Type B unit on the street floor or by a combination of the two. Multistory townh that incorporate a Type B unit on the street floor shall not be required to provide accessibility to f above or below the street floor. The Type B unit on the street floor shall include provisions for li sleeping, eating, cooking and a complete toilet and bathing facility on that floor. Exceptions: - pdf_text
2022 (cont. 2) (Add) 106.2.1 State agency and Connecticut Airport Authority exemption. Pursuant to section 29- of the Connecticut General Statutes, a state agency or the Connecticut Airport Authority shall n required to obtain a building permit from a local building official. A state agency or the authority obtain a building permit for construction work as described in section 29-252a of the Connecticut Ge Statutes from the State Building Inspector. (Amd) 106.4 By whom application is made. Pursuant to section 29-263 of the Connecticut Ge Statutes, application for a permit shall be made by the owner or by an authorized agent. If the autho agent is a licensed contractor, the provisions of section 20-338b of the Connecticut General Statutes be followed. The full names and addresses of the owner, agent and the responsible officers, if the own agent is a corporate body, shall be stated in the application. (Add) 106.4.1 Permit issuance to a home improvement contractor. No permit shall be issued contractor who is required to be registered pursuant to chapter 400 of the Connecticut General Statute work to be performed by such contractor, unless the name, business address and Department of Cons Protection registration number of such contractor is clearly marked on the permit application, an contractor has presented such contractor’s certificate of registration as a home improvement contracto - pdf_text
2022 (cont. 2) (Add) 407.14 Small I-2 homes. Group I-2 homes that serve 4 to 6 persons who are incapable of preservation and comply with the specific requirements of Section 407.14.1 shall be permitted to u the alternate compliance for the required items listed in Section 407.14.2. Other applicable provisio the code not addressed in Section 407.14.2 shall also apply. (Add) 407.14.1 Specific requirements. Small Group I-2 homes shall comply with Sections 407.1 through 407.14.1.11. (Add) 407.14.1.1 Separation of sleeping area. The sleeping area and its hallway shall be separated other habitable spaces such as living areas and kitchens by a smoke partition in accordance with Se - pdf_text
2022 (cont. 2) (Amd) R102.5 Appendices. The following appendices of the 2021 International Residential Cod hereby specifically adopted and included in this code: AE; AF; AG; AH; AK; AO; AP; AQ; and AY. (Amd) R102.7 Existing structures. The legal occupancy of any building or structure existing on the of adoption of this code shall be permitted to continue without change, except as specifically cover this code. (Del) SECTION R103 – DEPARTMENT OF BUILDING SAFETY. Delete Section R103 in its ent and replace with the following: (Add) SECTION R103 – ENFORCEMENT AGENCY (Add) R103.1 Creation of enforcement agency. Each town, city and borough shall create an agency w function is to enforce the provisions of this code. The official in charge thereof shall be known a building official. (Add) R103.2 Appointment. Pursuant to section 29-260 of the Connecticut General Statutes, the executive officer of any town, city or borough shall appoint an officer to administer this code, and officer shall be known as the “building official” and referred to in this code as the building official, l building official or code official. - pdf_text
2022 (cont. 2) (Amd) R301.2.1.4 Exposure category. For each wind direction considered, an exposure category adequately reflects the characteristics of ground surface irregularities shall be determined for the si which the building or structure is to be constructed. For a site located in the transition zone bet categories, the category resulting in the largest wind forces shall apply. Account shall be taken of variat in ground surface roughness that arise from natural topography and vegetation as well as from constru features. For a site where multiple detached one- and two-family dwellings, townhouses or other struct are to be constructed as part of a subdivision or master-planned community, or are otherwise designat a developed area by the authority having jurisdiction, the exposure category for an individual stru shall be based upon the site conditions that will exist at the time when all adjacent structures on the have been constructed, provided that their construction is expected to begin within 1 year of the sta construction for the structure for which the exposure category is determined. - pdf_text
2022 (cont. 2) (Amd) 308.4 Group I-3. Institutional Group I-3 occupancy shall include buildings and structures tha inhabited by more than three persons who are under restraint or security. A Group I-3 facility is occu by persons who are generally incapable of self-preservation due to security measures not under occupants’ control. This group shall include, but not be limited to, the following: Correctional centers Detention centers Jails Prerelease centers Prisons Reformatories Buildings of Group I-3 shall be classified as one of the occupancy conditions indicated in Sections 30 to 308.4.5, inclusive, and shall comply with Section 408. (Amd) 308.5 Institutional Group I-4, day care facilities. Institutional Group I-4 occupancy shall inc buildings and structures occupied by more than six persons of any age who receive custodial care for f than 24 hours per day by persons other than parents or guardians, relatives by blood, marriage or adop and in a place other than the home of the person cared for. This group shall include, but not be limite the following: Adult day care Child day care (Amd) 308.5.1 Classification as Group E. A child day care facility that provides care for more tha but not more than 100 children 3 years or less of age, where the rooms in which the children are care are located on the level of exit discharge serving such rooms and each of these child care rooms has an door directly to the exterior, shall be classified as Group E. - pdf_text
2022 (cont. 2) (Amd) FABRICATED ITEM. Structural, load-bearing or lateral load-resisting members or assem consisting of materials assembled prior to installation in a building or structure, or subjected to opera such as heat treatment, thermal cutting, cold working or reforming after manufacture and pri installation in a building or structure. Materials produced in accordance with standards referenced b code, such as rolled structural steel shapes, steel reinforcing bars, masonry units, wood structural p and structural composite lumber, or in accordance with a referenced standard that provides require for quality control done under the supervision of a third-party quality control agency, shall not be consi “fabricated items.” (Amd) FOSTER CARE FACILITIES. Facilities that provide care to more than three children, 3 yea age or younger. (Add) FULL CUTOFF LUMINAIRE. A luminaire that allows no direct light emissions abo horizontal plane through the luminaire’s lowest light-emitting part. (Add) GROUP R-1 BED AND BREAKFAST ESTABLISHMENT. A building that does not quali a one- or two-family dwelling unit in accordance with Section 101.2 and: - pdf_text
2022 (cont. 2) (Amd) 106.1 When required. Any owner or owner’s authorized agent who intends to construct, enl alter, repair, move, demolish or change the occupancy of a building or structure, or to move a lot lin will affect any existing building or structure, or to erect, install, enlarge, alter, repair, remove, conv replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated b code, or to cause any such work to be performed, shall first make application to the building officia obtain the required permit. (Add) 106.1.3 By whom application is made. Pursuant to section 29-263 of the Connecticut Ge Statutes, application for a permit shall be made by the owner or by an authorized agent. If the autho agent is a licensed contractor, the provisions of section 20-338b of the Connecticut General Statutes be followed. The full names and addresses of the owner, agent and the responsible officers, if the own agent is a corporate body, shall be stated in the application. (Add) 106.1.4 Permit issuance to a home improvement contractor. No permit shall be issued contractor who is required to be registered pursuant to chapter 400 of the Connecticut General Statute work to be performed by such contractor, unless the name, business address and Department of Cons Protection registration number of such contractor is clearly marked on the application for permit, an contractor has presented such contractor’s certificate of registration as a home improvement contracto - pdf_text
2022 (cont. 2) (Add) 105.3.1.2 Fire marshal approval. Pursuant to section 29-263 of the Connecticut General Stat no building permit for a building, structure or use subject to the requirements of the Connecticut State Safety Code shall be issued in whole or in part without certification in writing from the local fire ma that the construction documents for such building, structure or use are in substantial compliance wit requirements of the Connecticut State Fire Safety Code. (Add) 105.3.1.3 Historic certificate of appropriateness. Pursuant to subsection (b) of section 7-147 the Connecticut General Statutes, no building permit for erection of a building or structure or for alter of an exterior architectural feature within the boundaries of an historic property and no demolition pe for demolition or removal of a building or structure within the boundaries of an historic property sha issued by a municipality or any department, agency or official thereof until a certificate of appropriate has been issued. - pdf_text
2022 (cont. 2) (Amd) 115.4 Violation penalties. Pursuant to section 29-254a of the Connecticut General Statutes, person who violates any provision of this code shall be fined not less than two hundred nor more than thousand dollars or imprisoned not more than six months or both. (Amd) 116.4 Failure to comply. Any person who shall continue any work after having been served a stop work order, except such work as that person is directed to perform to remove a violation or u condition, shall be liable for penalties in accordance with Section 115.4. CHAPTER 2 – DEFINITIONS (Amd) 201.3 Terms defined in other codes. Where terms are not defined in this code and are defin other portions of the 2022 Connecticut State Building Code, such terms shall have the meanings asc to them as in those portions. (Add) 202.1 Definitions. Add or amend the following definitions: (Add) BUILDING OFFICIAL. The officer or other designated authority charged with the administr and enforcement of this code, or a duly authorized representative. Also known as the local building off or the code official. (Amd) CLEANOUT. An access opening in the drainage system utilized for the removal of obstruct Types of cleanouts include a removable plug or cap, and a removable fixture or fixture trap. Floor dr floor sinks, mop sinks and roof drains are not acceptable cleanouts. (Amd) CODE OFFICIAL. See Building Official. - pdf_text
2022 (cont. 2) (Amd) BUILDING, EXISTING. A building or structure, or portion thereof, erected in whole or in for which a legal building permit and a certificate of occupancy has been issued. Buildings or structur portions thereof erected prior to October 1, 1970 shall be deemed existing buildings regardless o existence of a legal permit or a certificate of occupancy. (Add) COMPLEX. For application of accessibility requirements, this term means any group of buil located on a single parcel of land or on contiguous parcels of land or any building or group of buil that are subdivided into separate occupancies and planned, financed, constructed or promoted by com management for the purpose of sale or lease of the entire complex or any subdivision thereof, exclu any single-family detached dwelling. (Add) Dwelling Unit Enclosure Area. The sum of the area of ceiling, floors and walls separati dwelling unit's conditioned space from the exterior or from adjacent conditioned or unconditioned s Wall height shall be measured from the finished floor of the dwelling unit to the underside of the above. (Add) ONE-FAMILY DWELLING. A building containing one dwelling unit with not more tha lodgers or boarders. Also known as a single-family dwelling. - pdf_text
2022 (cont. 2) (Amd) 1011.5.2 Riser height and tread depth. Stair riser heights shall be 7 inches (178 mm) maxi and 4 inches (102 mm) minimum. The riser height shall be measured vertically between the nosin adjacent treads. Rectangular tread depth shall be 11 inches (279 mm) minimum measured horizon between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tre nosing. Winder treads shall have a minimum tread depth of 11 inches (279 mm) between the vertical pl of the foremost projection of adjacent treads at the intersections with the walkline and a minimum t depth of 10 inches (254 mm) within the clear width of the stair. Exceptions: - pdf_text
2022 (cont. 2) (Amd) 102.6.2 Buildings previously occupied. The legal use and occupancy of any building existin the date of adoption of this code shall be permitted to continue without change, except as specifi provided in this code or the 2022 Connecticut State Fire Safety Code. (Add) 102.6.3 Demolition of structures. The demolition of structures shall be regulated in accordance the provisions of Section 3303 of this code. (Del) SECTION 103 – CODE COMPLIANCE AGENCY. Delete Section 103 in its entirety and replace with the following: (Add) SECTION 103 – ENFORCEMENT AGENCY (Add) 103.1 Creation of enforcement agency. Each town, city and borough shall create an agency w function is to enforce the provisions of this code. The official in charge thereof shall be known a building official. (Add) 103.2 Appointment. Pursuant to section 29-260 of the Connecticut General Statutes, the executive officer of any town, city or borough shall appoint an officer to administer this code, and officer shall be known as the building official and referred to herein as the building official, local buil official or code official. - pdf_text
2022 (cont. 3) (Add) 106.2.1 State agency and Connecticut Airport Authority exemption. Pursuant to section 29- of the Connecticut General Statutes, a state agency or the Connecticut Airport Authority shall n required to obtain a building permit from a local building official. A state agency or the authority obtain a building permit for construction work, as described in section 29-252a of the Connecticut Ge Statutes, from the State Building Inspector. (Amd) 106.4 Permit issuance. Pursuant to section 29-263 of the Connecticut General Statutes, the buil official shall examine or cause to be examined applications for permits and amendments thereto withi days after filing and either issue or deny a permit within such 30-day period. If the applicatio construction documents do not conform to the requirements of this code and pertinent laws, the buil official shall reject such application in writing, stating the reasons therefor. If the building offici satisfied that the proposed work conforms to the requirements of this code and applicable laws, stat regulations and ordinances, the building official shall issue a permit therefor as soon as practicable. (Amd) 107.2 Retention of construction documents. The building official shall retain one set of appr construction documents for a period as set forth in the records/disposition schedule adopted pursua chapter 188 of the Connecticut General Statutes. - pdf_text
2022 (cont. 3) n of the design by reviewing the fabrication pro to ensure conformance with the design specifications and parameters. The additional requirements set in this subsection shall not apply to alterations, repairs, relocation or change of occupancy to any exi building. - pdf_text
2022 (cont. 3) (Add) R301.2.1.4.1 Wind directions and sectors. For each selected wind direction at which the loads are to be evaluated, the exposure of the building or structure shall be determined for the two up sectors extending 45 degrees (0.79 rad) on either side of the selected wind direction. The exposure these two sectors shall be determined in accordance with Sections R301.2.1.4.2 and R301.2.1.4.3, and exposure resulting in the highest wind loads shall be used to represent winds from that direction. (Add) R301.2.1.4.2 Surface roughness categories. A ground surface roughness within each 45-de (0.79 rad) sector shall be determined for a distance upwind of the site, as defined in Section R301.2.1 from the categories defined below, for the purpose of assigning an exposure category, as defined in Sec R301.2.1.4.3. Surface Roughness B. Urban and suburban areas, wooded areas or other terrain with numer closely spaced obstructions having the size of single-family dwellings or larger. Surface Roughness C. Open terrain with scattered obstructions having heights generally less than - pdf_text
2022 (cont. 3) (Add) 3103.5.9.5 Separation of generators. Generators and other internal combustion power sources be separated from tents or membrane structures by a minimum of 20 feet (6096 mm) and shall be iso from contact with the public by fencing, enclosure or other approved means. (Amd) 3105.2 Design and construction. Awnings and canopies shall be designed and construct withstand wind or other lateral loads and live loads as required by Chapter 16 with due allowance for s open construction and similar features that relieve the pressures or loads. Structural members sha protected to prevent deterioration. Awnings shall have frames of noncombustible material, fire-retar treated wood, heavy timber complying with Section 2304.11, or 1-hour construction with combustib noncombustible covers and shall be either fixed, retractable, folding or collapsible. - pdf_text
2022 (cont. 3) (Add) 107.8 Lift-slab construction. Pursuant to subsection (b) of section 29-276a of the Connec General Statutes, any building designed to be constructed utilizing the lift-slab method of construction be classified as exceeding the “threshold limit” and shall be subject to the provisions of Sections 10 of this code and construction thereof shall comply with the provisions of 29 CFR 1926 and section 31- - pdf_text
2022 (cont. 3) (Amd) REGISTERED DESIGN PROFESSIONAL. An individual who is registered or licensed b Department of Consumer Protection pursuant to chapters 390, 391, 396 or 396a of Connecticut Ge - pdf_text
2022 (cont. 3) (Add) 113.1.2 State Building Inspector review. Pursuant to subsection (d) of section 29-252 o Connecticut General Statutes, the State Building Inspector or his designee shall review a decision by a l building official or municipal board of appeals, when he has reason to believe that such official or b has misconstrued or misinterpreted any provision of the State Building Code. (Add) 113.2 Appointment of municipal board of appeals. Pursuant to subsection (a) of section 29 of the Connecticut General Statutes, a municipal board of appeals consisting of five members sha appointed. (Add) 113.2.1 Qualifications. One member of the municipal board of appeals shall be appointed fro general public. The other four members shall each have at least five years of experience in building de building construction or supervision of building construction. (Add) 113.2.2 Chairperson. The board shall annually select one of its members to serve as chairpers (Add) 113.3 Notice of meeting. Each appeal under this subsection shall be heard in the municipalit which the building official serves within five days, exclusive of Saturdays, Sundays and legal holi after the date of receipt of the appeal. (Add) 113.4 Determination of aggrievement. Upon receipt of an appeal from a person other tha owner or his agent, the board of appeals shall first determine whether such person has a right to appea - pdf_text
2022 (cont. 3) (Add) 116.6.2 Unlawful to remove seal. Any device or equipment sealed out of service by the buil official or his authorized representative shall be plainly identified as out of service by such official shall indicate the reason for such sealing. The identification shall not be tampered with, defaced or rem except by the building official or his authorized representative. (Add) 116.7 Hazardous conditions. Pursuant to the provisions of section 29-393 of the Connec General Statutes, on receipt of information from the local fire marshal or from any other authentic so that any building in his jurisdiction, due to lack of exit facilities, fire, deterioration, catastrophe or cause, is in such condition as to be a hazard to any person or persons, the building official shall immedi make an inspection by himself or by his assistant, and may make orders for additional exit facilities o repair or alteration of the building if the same is susceptible to repair or both or for the removal of building or any portion thereof if any such order is necessary in the interests of public safety. Any buil official shall have the right of entry into all buildings for the performance of his duties between the h of nine o'clock a.m. and five o'clock p.m., in the interests of public safety. - pdf_text
2022 (cont. 3) (Add) 422.8 Laboratories. In addition to other requirements of this code, laboratories employing quan of flammable, combustible or hazardous materials that exceed exempt amounts shall be protect accordance with NFPA 99. (Add) 422.9 Medical gas systems. Medical gas systems shall comply with Chapter 12 of the Internat Plumbing Code and Section 5306 of the International Fire Code. (Amd) 424.5 Area limits. Children’s play structures greater than 600 square feet (56 m²) in area comply with Section 411. - pdf_text
2022 (cont. 3) (Add) 3103.5.7.1 Label. Membrane structures or tents shall have a permanently affixed label bearin following information: - pdf_text
2022 (cont. 3) (Add) 104.10.1 State Building Code. Pursuant to subsection (b) of section 29-254 of the Connec General Statutes, the State Building Inspector may grant modifications, variations or exemptions fro approve equivalent or alternative compliance with, the Connecticut State Building Code where compliance with the Connecticut State Building Code would entail practical difficulty or unneces hardship, or is otherwise adjudged unwarranted, provided the intent of the law shall be observed and p welfare and safety be assured. Any person aggrieved by any decision of the State Building Inspector appeal to the Codes and Standards Committee not later than 30 days after mailing of the decision. (Add) 104.10.1.1 Action on application. The application for modification, variation, exemption fro approval of equivalent or alternative compliance with the requirements of the Connecticut State Buil Code shall be made on a form supplied by the State Building Inspector, which shall be submitted b applicant to the building official. Pursuant to subsection (b) of section 29-254 of the Connecticut Ge Statutes, any such application received by a building official shall be forwarded to the State Buil Inspector within 15 business days of receipt by such building official. The application shall includ building official’s comments on the merits of the application and shall be signed by the building offici - pdf_text
2022 (cont. 3) (Add) BUILDING OFFICIAL. The officer or other designated authority charged with the administr and enforcement of this code, or a duly authorized representative. Also known as the local building off or code official. (Amd) CODE OFFICIAL. See Building Official. - pdf_text
2022 (cont. 3) (Amd) R103.1 General. Construction documents and other supporting data shall be submitted in o more sets, or in a digital format where allowed by the building official, with each application for a pe The construction documents shall be prepared by a registered design professional when required b provisions of chapters 390 or 391 of the Connecticut General Statutes. Exception: The building official may waive the submission of construction documents or supporting data if the building official determines they are not necessary to confirm compli with this code. - pdf_text
2022 (cont. 3) Exception No. 1: Luminaires more than 2.3 m (71∕ 2 ft) above the floor and switches located outside patient care vicinity shall be permitted to be connected to an equipment grounding return path comp with 517.13(A) or (B). (A) Wiring Methods. All branch circuits serving patient care spaces shall be provided with an effe ground-fault current path by installation in a metal raceway system or a cable having a metallic arm sheath assembly. The metal raceway system, metallic cable armor, or sheath assembly shall itself qu as an equipment grounding conductor in accordance with 250.118. - pdf_text
2022 (cont. 3) (Add) R112.1 Appeal from decision of building official. Pursuant to subsection (b) of section 29-2 the Connecticut General Statutes, when a building official rejects or refuses to approve the mode or ma of construction proposed to be followed or the materials to be used in the erection or alteration of a buil or structure, or when it is claimed that the provisions of the code do not apply or that an equally go more desirable form of construction can be employed in a specific case, or when it is claimed that the intent and meaning of the code has been misconstrued or wrongly interpreted or when the building off issues a written order under subsection (c) of section 29-261 of the Connecticut General Statutes, the o of such building or structure, whether already erected or to be erected, or his authorized agent may ap in writing or by electronic mail from the decision of the building official to the municipal board of app A person, other than such owner, who claims to be aggrieved by any decision of the building official by himself or his authorized agent, appeal in writing or by electronic mail from the decision of the buil official to the municipal board of appeals as provided by subsection (b) of section 29-266 of the Connec General Statutes. (Add) R112.1.1 Absence of municipal board of appeals. In the absence of a municipal board of app the provisions of subsection (c) of section 29-266 of the Connecticut General Statutes shall be follow - pdf_text
2022 (cont. 3) (Add) 105.3.1.4 Notice to Public Water Authority. Pursuant to section 19a-37d of the Connec General Statutes, when a permit application is filed with the building official concerning any project includes a change of use or installation of fixtures or facilities in a building that may affect the perform of, or require the installation of, a reduced pressure principle backflow preventer, a double check assembly or a pressure vacuum breaker, the building official shall provide written notice of the applic to the water company serving the building not later than seven days after the date the application is Upon receipt of such written notice, the water company shall cause to be performed an evaluation of c connection protection by a person who has met the requirements prescribed in the Regulatio Connecticut State Agencies and such water company shall notify the building official regardin determination. The building official shall not issue a permit or certificate of occupancy until any c connection issue has been corrected. - pdf_text
2022 (cont. 3) (Amd) REGISTERED DESIGN PROFESSIONAL. An individual who is registered or licensed b Department of Consumer Protection pursuant to chapters 390, 391, 396 or 396a of the Connecticut Ge Statutes to practice the individual’s respective design profession and acting within the scope of his o license and practice discipline. (Add) TWO-FAMILY DWELLING. A building containing two dwelling units with not more tha lodgers or boarders per dwelling unit. - pdf_text
2022 (cont. 3) (Amd) 708.1.1 Horizontal drains and building drains. Horizontal drainage pipes, including horiz branch drains consisting of one or more fixtures, in buildings shall have cleanouts located at interva not more than 100 feet (30,480 mm). Building drains shall have cleanouts located at intervals of not than 100 feet (30,480 mm) except where manholes are used instead of cleanouts, the manholes sha located at intervals of not more than 400 feet (122 m). The interval length shall be measured fro cleanout or manhole opening, along the developed length of the piping to the next drainage fitting provi access for cleaning, the end of the horizontal drain or the end of the building drain. Exception: Horizontal fixture drain piping serving a non-removable trap shall not be required to a cleanout for the section of piping between the trap and the connection to a horizontal or vertical if located within 4 feet (1219 mm) of developed length of such connection. The 4 feet (1219 mm) be measured from the fixture trap weir to the connection at the horizontal or vertical piping. CHAPTER 9 – VENTS (Amd) 903.1.1 Roof extension unprotected. Open vent pipes that extend through a roof shall be termi not less than 12 inches above the roof. (Del) 903.2 Frost closure. Delete section. CHAPTER 10 - TRAPS, INTERCEPTORS AND SEPARATORS - pdf_text
2022 (cont. 3) (Amd) R106.5 Retention of construction documents. Pursuant to subsection (e) of section 29-261 o Connecticut General Statutes, upon receipt of a written request signed by the owner of plans specifications on file for a single-family dwelling or out-building, the building official shall immedi return the original plans and specifications to the owner after a certificate of occupancy is issued respect to the plans and specifications. (Add) R106.6 Additional requirements. Nontransient residential dwellings having more than 16 uni - pdf_text
2022 (cont. 3) (Amd) 106.5 Permit issuance. Pursuant to section 29-263 of the Connecticut General Statutes, the buil official shall examine or cause to be examined applications for permits and amendments thereto withi days after filing and either issue or deny a permit within such 30-day period. If the applicatio construction documents do not conform to the requirements of this code and pertinent laws, the buil official shall reject such application in writing, stating the reasons therefor. If the building offici satisfied that the proposed work conforms to the requirements of this code and applicable laws, stat regulations and ordinances, the building official shall issue a permit therefor as soon as practicable. (Add) 112.2.6 Posting of required inspections. A schedule of required inspections shall be compile the code official. The schedule shall be posted in the building department for public view. (Add) 112.5 Notification of inspection and testing results. Notification as to passage or failure, in w or in part, of any required inspection or test shall be made in writing by the building official or his authorized representative and shall be left at the job site or delivered to the permit holder. It shall b duty of the permit holder to ascertain the results of required inspections. - pdf_text
2022 (cont. 3) SPA. A product intended for the immersion of persons in temperature-controlled water circulated closed system, and not intended to be drained and filled with each use. A spa usually includes a filte electric, solar or gas heater, a pump or pumps, and a control, and can include other equipment, su lights, blowers, and water-sanitizing equipment. Nonself-contained spa. A factory-built spa in which the water heating and circulating equip is not an integral part of the product. Nonself-contained spas may employ separate compo such as an individual filter, pump, heater and controls, or they can employ assembled combina of various components. Permanent residential spa. A spa, intended for use that is accessory to a residential settin available to the household and its guests and where the water heating and water-circul equipment is not an integral part of the product. The spa is intended as a permanent plum fixture and not intended to be moved. Portable residential spa. A spa intended for use that is accessory to a residential setting available to the household and its guests and where it is either self-contained or nonself-conta Public spa. See “public pool”. Self-contained spa. A factory-built spa in which all control, water heating and water-circul equipment is an integral part of the product. Self-contained spas may be permanently wired or connected. CHAPTER 3 – PROVISIONS FOR ALL COMPLIANCE METHODS - pdf_text
2022 (cont. 3) (A) Structural floor, wall, ceiling and roof members. (1) Solid sawn lumber. Notches in solid lumber joists, rafters and beams shall not exceed one-sixth o depth of the member, shall not be longer than one-third of the depth of the member and shall not be lo in the middle one-third of the span. Notches at the ends of the member shall not exceed one-fourth the of the member. The tension side of members 4 inches (102 mm) or greater in nominal thickness shal be notched except at the ends of the members. The diameter of holes bored or cut into members shal exceed one-third the depth of the member. Holes shall not be closer than 2 inches (51 mm) to the t bottom of the member, or to any other hole located in the member. Where the member is also notche hole shall not be closer than 2 inches (51 mm) to the notch. Exception: Notches on cantilevered portions of rafters are permitted provided the dimension of remaining portion of the rafter is not less than 4-inch (102 mm) nominal and the length of the cantil does not exceed 24 inches (610 mm). - pdf_text
2022 (cont. 3) (Amd) 312.10.2 Testing. Required reduced pressure principle, double check, pressure vacuum bre reduced pressure detector fire protection, double check detector fire protection, and spill-proof vac breaker backflow preventer assemblies and hose connection backflow preventers shall be tested at the of installation by individuals or agencies qualified to perform such inspections. It shall be the responsi of the owner to have such tests performed and copies of test reports shall be given to the local buil official. The testing procedure shall be performed in accordance with one of the following standards: - pdf_text
2022 (cont. 3) (Add) AF105.2 “T” fitting and vent pipe. Before a slab is cast or other floor system is installed, a 3 “T” fitting shall be inserted beneath the soil-gas-retarder. The “T” fitting shall be surrounded by aggr consisting of material that will pass through a 2-inch (51 mm) sieve and be retained by a ¼-inch (6.4 sieve not less than an 8-inch (203 mm) deep by 24-inch (610 mm) diameter hole. The aggregate sha wrapped in filter fabric or equivalent material. The “T” fitting shall be connected to a 3-inch-diamete mm) ABS or PVC vent pipe extending from the basement through the conditioned space of the dwe and terminate and be capped not less than 12 inches (305 mm) above the roof in a location not less th feet (3048 mm) away from any window or other opening into the conditioned spaces of the building t less than 2 feet (610 mm) below the exhaust point. The vent pipe shall be the same diameter througho length and shall be supported in accordance with Section P2605. The vent pipe shall be labeled a bottom and in the attic and shall specifically state: “Reserved for a Potential Radon Reduction Mecha System.” (Add) AF105.2.1 Combination foundations. Where basement or crawl space floors are on different le each level shall have a separate vent pipe. Multiple vent pipes shall be permitted to be connected to a s vent pipe that terminates above the roof. - pdf_text
2022 (cont. 3) (Amd) 308.5.3 Six or fewer persons receiving care in other than a dwelling unit. A facility havin or fewer persons receiving custodial care in other than a dwelling unit shall be classified as part o primary occupancy. - pdf_text
2022 (cont. 3) (Amd) Authority having jurisdiction. The organization, office or individual responsible for appro equipment, material, an installation, or a procedure. The local building official has the responsibilit approving construction documents, issuing permits, approving materials and procedures and for ma inspections from time to time as the construction process requires. The State Building Inspector ha responsibility for administering the Connecticut State Building Code, interpreting the Connecticut Building Code and for granting exceptions from specific rules of the Connecticut State Building Code the definition of “Special Permission,” and Article 90.4. (Amd) Special Permission. For the purposes of this code, the authority having jurisdiction for grantin special permission contemplated in a number of rules is the State Building Inspector. Special permis shall be requested in writing using the Request for Modification of the State Building Code form avail from local building departments or from the Office of the State Building Inspector, 450 Colu Boulevard, Suite 1303, Hartford CT 06103. www.portal.ct.gov/DAS. - pdf_text
2022 (cont. 3) (Add) R103.3 Employees. In accordance with the prescribed procedures and regulations of the town, or borough, and with the concurrence of the appointing authority, the building official shall hav authority to appoint an assistant building official, related technical officers, inspectors, plan examiners other employees. Such employees shall have the powers as regulated by the town, city or borough, an the state of Connecticut. (Add) R103.4 Restriction of employees. An official or employee connected with the agency creat enforce the provisions of this code pursuant to Section R103.1, except one whose only connection w is that of a member of the board of appeals established under the provisions of Section R112, shall n engaged in, or directly or indirectly connected with, the furnishing of labor, materials or appliances fo construction, addition, alteration, repair or maintenance of a building located in the town, city or bor in which such official or employee is employed, or the preparation of construction documents ther - pdf_text
2022 (cont. 3) (Amd) 103.3 Employees. In accordance with the prescribed procedures and regulations of the town, or borough, and with the concurrence of the appointing authority, the building official shall hav authority to appoint an assistant building official, related technical officers, inspectors, plan examiners other employees. Such employees shall have the powers as regulated by the town, city or borough, an the state of Connecticut. (Add) 103.4 Restriction of employees. An official or employee connected with the agency create enforce the provisions of this code pursuant to Section 103.1, except one whose only connection with that of a member of the board of appeals established under the provisions of Section 113, shall n engaged in or directly or indirectly connected with the furnishing of labor, materials or appliances fo construction, addition, alteration, repair or maintenance of a building located in the town, city or bor in which such official or employee is employed, or the preparation of construction documents ther unless that person is the owner of the building. Such officer or employee shall not engage in any work conflicts with official duties or with the interests of the agency. - pdf_text
2022 (cont. 3) (Amd) C103.1 General. Construction documents and other supporting data shall be submitted in o more sets, or in a digital format where allowed by the building official, with each application for a pe The construction documents shall be prepared by a registered design professional when required b provisions of chapters 390 or 391 of the Connecticut General Statutes. Exception: The building official may waive the submission of construction documents or supporting data if the building official determines they are not necessary to confirm compli with this code. (Amd) C103.5 Retention of construction documents. The building official shall retain one set of appr construction documents for a period as set forth in the records/disposition schedule adopted pursua chapter 188 of the Connecticut General Statutes. (Del) SECTION C104 – FEES. Delete in its entirety and refer to Section 109 of the 2021 Internati Building Code portion of the 2022 Connecticut State Building Code – Fees. - pdf_text
2022 (cont. 4) (Add) 104.10.1.2 Records. The application for modification, variation, exemption or approva equivalent or alternative compliance and the decision of the State Building Inspector shall be in wr and shall be officially recorded with the application for a building permit in the permanent records o building department. - pdf_text
2022 (cont. 4) (Add) R112.1.2 State Building Inspector review. Pursuant to subsection (d) of section 29-252 o Connecticut General Statutes, the State Building Inspector or his designee shall review a decision local building official or municipal board of appeals when he has reason to believe that such offici board has misconstrued or misinterpreted any provision of the Connecticut State Building Code. (Add) R112.2 Appointment of municipal board of appeals. Pursuant to subsection (a) of section 29 of the Connecticut General Statutes, a municipal board of appeals consisting of five members sha appointed. - pdf_text
2022 (cont. 4) (Amd) 1003.3 Grease interceptors. Grease interceptors that serve plumbing systems connected to pri on-site septic systems shall comply with the requirements of Sections 1003.3.1 to 1003.3.5, inclusiv - pdf_text
2022 (cont. 4) (Add) 105.3.3 By whom application is made. Pursuant to section 29-263 of the Connecticut Ge Statutes, application for a permit shall be made by the owner or by an authorized agent. If the autho agent is a licensed contractor, the provisions of section 20-338b of the Connecticut General Statutes be followed. The full names and addresses of the owner, agent and responsible officers, if the own agent is a corporate body, shall be stated in the application. (Add) 105.3.4 Permit issuance to a home improvement contractor. No permit shall be issued contractor who is required to be registered pursuant to chapter 400 of the Connecticut General Statute work to be performed by such contractor, unless the name, business address and Department of Cons Protection registration number of such contractor are clearly marked on the permit application, an contractor has presented such contractor’s certificate of registration as a home improvement contracto - pdf_text
2022 (cont. 4) (Amd) 109.2 Schedule of permit fees. Each municipality shall establish a schedule of fees for construction document review, building permit, certificate of approval and certificate of occupanc schedule of adopted fees shall be posted in the building department for public view. (Del) 109.3 Work commencing before permit issuance. Delete section. - pdf_text
2022 (cont. 4) (Amd) 302.1 Electrical. Electrical requirements for aquatic facilities shall be in accordance with the NFPA 70 portion of the 2022 Connecticut State Building Code. Exception: Internal wiring for portable residential spas and portable residential exercise spa - pdf_text
2022 (cont. 4) (Add) 107.7 Threshold limits. Pursuant to section 29-276b of the Connecticut General Statutes, section shall apply to any proposed structure or addition thereto that exceeds one or more of the follo threshold limits: - pdf_text
2022 (cont. 4) (Add) AF105.2.2 Drain tile and sump used for depressurization. As an alternative to inserting a pipe into a “T” fitting, a vent pipe shall be permitted to be inserted directly into an interior perimeter tile loop or through a sump cover. (Add) AF105.3 Floor openings. Openings around bathtubs, showers, water closets, pipes, wires or objects that penetrate concrete slabs, or other floor assemblies, shall be filled with a polyurethane cau - pdf_text
22 22/3 (32 inches) PE-RT 1 inch and smaller - pdf_text
22 22/3 (32 inches) PE-RT 11/4 inches and larger - pdf_text
22 22/3 (32 inches)d Cross-linked polyethylene/aluminum/crosslinked polyethylene (PEX-AL-PEX) pipe 1 inch and larger - pdf_text
22 22/3 (32 inches) PEX tubing 11/4 inches and larger - pdf_text
22 22/3 (32 inches)d Polypropylene (PP) pipe or tubing, 11/4 inches and larger - pdf_text
24 24,000 square feet (2230 m2) total gross area per building shall be subject to the additional requirem set forth in Section 107.6 of the 2021 International Building Code portion of the 2022 Connecticut Building Code. (Amd) R107.1 General. The building official is authorized to issue a permit for temporary structures temporary uses. Such permits shall be limited as to time of service, but shall not be permitted for more - pdf_text
24 24,000 square feet (2230 m2). - pdf_text
25 25 percent but not less than one room for each use at each cluster shall be accessible. - pdf_text
253a 253a of the Connecticut General Statutes, such spaces shall be designated by above-grade s with white lettering against a blue background and shall bear the words “RESERVED Par Permit Required” and “Violators will be fined” in addition to the International Symb Accessibility. When such a sign is replaced, repaired or erected, it shall indicate the minimum for a violation of subsection (l) of section 14-253a of the Connecticut General Statutes. indicator may be in the form of a notice affixed to such sign. Newly installed signs shall b inches (1525 mm) minimum above the floor or ground of the parking space, measured to the bo of the sign. - pdf_text
29-200 29-200 of the Connecticut General Statutes, the following exceptions are allowed: Exceptions: - pdf_text
29-256 29-256a of the Connecticut General Statutes. - pdf_text
29-266 29-266 of the Connecticut General Statutes. (Add) R112.8 Court review. Any person aggrieved by any ruling of the Codes and Standards Comm may appeal to the Superior Court for the judicial district where such building or structure has been being erected in accordance with the provisions of subsection (d) of section 29-266 of the Connec General Statutes. (Add) R113.2.1 Written notice. The building official or his duly authorized representative shall pro any notice of violation in writing to the owner of the property involved or to the owner’s agent or t person doing the work. (Amd) R113.4 Violation penalties. Pursuant to section 29-254a of the Connecticut General Statutes, person who violates any provision of this code shall be fined not less than two hundred nor more than thousand dollars or imprisoned not more than 6 months, or both. (Amd) R114.4 Failure to comply. Any person who continues any work in or about the structure having been served with a stop work order, except such work as that person is directed to perform to re a violation or unsafe conditions, shall be liable for penalties in accordance with Section R113.4. (Add) SECTION R115 - UNSAFE STRUCTURES AND EQUIPMENT (Add) R115.1 General. The procedures to be followed regarding unsafe structures and equipment sh as set forth in Section 116 of the 2021 International Building Code portion of the 2022 Connecticut Building Code. - pdf_text
29-277 29-277 of the Connecticut General Statutes. (Add) STREET FLOOR. For application of accessibility requirements, this term means the floor ne the level of exit discharge. (Add) TECHNICALLY INFEASIBLE. An alteration of a building or a facility that has little likeli of being accomplished because the existing structural conditions require the removal or alteration load-bearing member that is an essential part of the structural frame, or because other physical or constraints prohibit modification or addition of elements, spaces or features that are in full and compliance with the minimum requirements for new construction and that are necessary to pro accessibility. Pursuant to subsection (b) of section 29-269 of the Connecticut General Statutes, determination of technical infeasibility shall be made by the State Building Inspector. (Amd) TYPE B UNIT. A dwelling unit or sleeping unit designed and constructed for accessibilit accordance with this code and the provisions for Type B units in ICC/ANSI A117.1, as amended. - pdf_text
298 298 of the Connecticut General Statutes, and employed by the jurisdiction in which the building or stru is being constructed, shall be considered an approved agency for the portions of this code also regulat the Connecticut State Fire Safety Code. Pursuant to subsection (e)(1) of section 29-276b of the Conne General Statutes, an approved agency conducting tests or furnishing inspection services of soils or con - pdf_text
3 3. Retaining walls that are not higher than 3 feet (914 mm) measured from finished grade at the bo of the wall to finished grade at the top of the wall, unless supporting a surcharge. - pdf_text
3 3. Constructed in accordance with ASCE 32. - pdf_text
3 3 CPVC pipe or tubing, 11/4-inches and larger - pdf_text
3 3. Inspect Connections a. Bolted and screwed connections, including diameter, length, spacing and edge distance b. Nailed connections, including diameter, length, type and spacing of nails c. Proprietary hangers and framing anchors, including fastener sizes and quantities d. Tie-down anchors, including anchor rod size and fastener sizes and quantities X X X X - pdf_text
3 3. Where at least one parking space is provided for each dwelling unit or sleeping unit, at least accessible parking space shall be provided for each Accessible and Type A - pdf_text
3 3. Where commercial kitchen grease ducts are continuously covered on all sides with a listed labeled field-applied grease duct enclosure material, system, product or method of constru specifically evaluated for such purpose in accordance with ASTM E2336, the required clear shall be in accordance with the listing of such material, system, product or method. (Add) 506.3.6.1 Clearance reduction. The clearances required by Section 506.3.6 shall be permitted reduced in accordance with Section 308. (Amd) 507.2.6 Clearances for Type I hood. A Type I hood shall be installed with a clearan combustibles of not less than 18 inches (457 mm), 3 inches (76 mm) to limited-combustible material - pdf_text
3 3. The fire area is located on a floor other than a level of exit discharge serving such occupanci (Add) 903.2.3.1 Statutory requirements. Pursuant to section 29-315 of the Connecticut General Sta an automatic sprinkler system shall be installed in Group E occupancies. - pdf_text
3 3. Snow load importance factor, Is. - pdf_text
3 3. Tents 900 square feet (84 m2) and smaller in total area when occupied by fewer than 50 per which have no heating appliances, no installed electrical service and are erected for fewer - pdf_text
3 3. Eave height of 10 feet (3048 mm) or less. Shallow foundations shall not bear or be installed on frozen soil. CHAPTER 22 – STEEL (Amd) 2211.1.3.2 Trusses spanning 60 feet or greater. The owner, the owner’s authorized agent or contractor shall contract with a qualified registered design professional for the design of the temporar installation restraint/bracing and the permanent individual truss member restraint/bracing for trusses clear spans 60 feet (18 288 mm) or greater. Special inspection of trusses over 60 feet (18 288 mm) in length shall be in accordance with Section 1705.2. CHAPTER 23 – WOOD (Add) 2303.1.1.3 Ungraded lumber. Pursuant to section 29-256b of the Connecticut General Statutes use of ungraded lumber shall be allowed in Group U Utility and Miscellaneous structures in accord with Section 312. (Amd) 2303.4.1.3 Trusses spanning 60 feet or greater. The owner, the owner’s authorized agent o contractor shall contract with a qualified registered design professional for the design of the temp installation restraint and diagonal bracing and the PITMR and PITMDB for all trusses with clear span feet (18 288 mm) or greater. CHAPTER 26 - FOAM PLASTIC INSULATION - pdf_text
3 3. The angle between guys and the horizon shall conform to the tent manufactu requirements and shall not be less than 45 degrees nor more than 68 degrees. - pdf_text
3 3. Where photovoltaic arrays are installed on only one side of the valley beam of a valleyed and there is clear access on the opposing slope, and that opposing slope has at least one access point in accordance with Section R324.6.3, the pathways from the lowest roof ed the ridge shall not be required on the roof slope containing the photovoltaic arrays. (Add) R324.6.4 Roof access points. Where required by other sections of this code, roof access points be located in areas that do not require the placement of ground ladders over openings, such as windo doors, and located at strong points of building construction in locations where the access point doe conflict with overhead obstructions such as tree limbs, wires or signs. - pdf_text
3 3. BIPV systems listed in accordance with Section 690.12(B)(2) of NFPA 70, where the remov cutting away of portions of the BIPV system during fire-fighting operations has been deter to not expose a fire fighter to electrical shock hazards. (Amd) R324.6.1 Pathways. Not fewer than two pathways, on separate roof planes from lowest roof to ridge and not less than 36 inches (914 mm) wide, shall be provided on all buildings. Not fewer tha pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photov array, a pathway not less than 36 inches (914 mm) wide shall be provided from the lowest roof ed ridge on the same roof plane as the photovoltaic array, on an adjacent roof plane, or straddling the and adjacent roof planes. Pathways shall be over areas capable of supporting fire fighters accessin roof. Pathways shall be located in areas with minimal obstructions such as vent pipes, conduit or mecha equipment. Exceptions: - pdf_text
3 3 Amendments to ICC A117.1-2017 - pdf_text
3 3. At elevated walking surfaces for access to and use of electrical, mechanical or plumbing sys or equipment, guards shall not have openings which allow passage of a sphere 21 inches (533 in diameter. - pdf_text
3 3. The name of the individual performing the analysis and generating the compliance report - pdf_text
3 3. Structural, plumbing, and mechanical work shall conform to the requirements of this code. (Amd) 105.2 Work exempt from permit. Exemption from the permit requirements of this code shal be deemed to grant authorization for any work to be done in any manner in violation of the provisio this code or any other laws, statutes, regulations or ordinances of the jurisdiction. Permits shall n required for the following: - pdf_text
3 3. A statement that the fabric or material meets the requirements of Section 3102.3.1.2. - pdf_text
3 3. In new buildings for which a building permit application has been filed on or after October 1, in accordance with the 2022 Connecticut State Building Code. - pdf_text
3 3. Portions of buildings or structures designed under the 1971 edition of the Connecticut Building Code that are not subjected to snow drifting effects. - pdf_text
3 3. Decks and ramps not supported by a dwelling need not be provided with footings that extend b the frost line. - pdf_text
3 3. Where provided in below-grade transportation stations, existing and new escalators sha permitted to have a clear width of less than 32 inches (815 mm). (Del) 503.12 Roof diaphragms resisting wind loads in high-wind regions. Delete section in its enti CHAPTER 7– ALTERATIONS – LEVEL 1 (Amd) 702.7.1 International Fuel Gas Code. The International Fuel Gas Code is not adopted by the of Connecticut. Any references to the International Fuel Gas Code within the body of this code sha considered references to requirements of NFPA 2, Hydrogen Technologies Code, NFPA 54, National Gas Code and NFPA 58, Liquefied Petroleum Gas Code, as incorporated in the 2022 Connecticut Fire Safety and the Connecticut State Fire Prevention Codes. These requirements apply to liquid petrol storage systems, gas piping systems extending from the point of delivery to the inlet connection appliances, the installation and operation of residential and commercial gas appliances and rel accessories as covered by this code. (Add) 704.4 Minimum standards. In addition to the requirements of this code, means of egress in exi buildings shall meet the requirements of the 2022 Connecticut State Fire Prevention Code for the prop occupancy. - pdf_text
3 3. Otherwise makes the means of egress path not readily available because of the nature o attraction or mode of conveyance through the building or structure. Exception: Children’s play structures that do not exceed 10 feet in height and do not have an aggre horizontal projection in excess of 300 square feet. (Amd) SPRAY-APPLIED FOAM PLASTIC. Single- and multiple-component, spray-applied f plastic insulation used in nonstructural applications that are installed at locations wherein the materi applied in a liquid or frothed state, permitted to free rise and cure in situ and certified pursuant to se - pdf_text
3 3. With a clear span of 150 feet in width; - pdf_text
3 3. Beams, girders, ducts or other obstructions in basements containing habitable space shal permitted to project to within 6 feet 4 inches (1931 mm) of the finished floor. - pdf_text
3 3. In Group R-3 occupancies, a change in elevation consisting of a single riser at an entrance or e door does not require handrails. - pdf_text
3 3. Tents 900 square feet and smaller in total area when occupied by fewer than 50 persons, have no heating appliances, no installed electrical service and are erected for fewer than 72 h (Add) 3103.5.2 Use period. Temporary tents or air-supported, air-inflated or tensioned mem structures shall not be erected for a period of more than 180 days within a 12-month period on a s premises. (Add) 3103.5.3 Construction documents. A detailed site and floor plan for tents or membrane struc with an occupant load of 50 or more shall be provided with each permit application. The tent or mem structure floor plan shall indicate details of the means of egress facilities, seating capacity, arrangeme the seating, and location and type of heating and electrical equipment. The construction documents include an analysis of structural stability. Tents and membrane structures erected in accordance with Se - pdf_text
3 3. Replacement of branch circuit overcurrent devices of the required capacity in the same locati - pdf_text
3 3. A statement that the fabric or material meets the requirements of Section 3103.5.7.2. - pdf_text
3 3. Existing buildings converted prior to June 15, 1994, from a one- or two-family building or G R-3 to Group R-2 containing not more than four dwelling units. - pdf_text
3 3. The townhouse shall be separated from adjoining units in accordance with Section R302.2 o International Residential Code. Errata #2 - should be CFSC - pdf_text
3 3. The material shall have a structural base of a noncombustible material with a surfacin exceeding a thickness of 1/8 inch (3.2mm) where the surfacing exhibits a flame spread inde greater than 50 when tested in accordance with ASTM E 84, Standard Test Method for Su Burning Characteristics of Building Materials, or ANSI/UL 723, Standard for Test for Su Burning Characteristics of Building Materials. - pdf_text
3 3. A fire alarm system is not required in buildings that do not have interior corridors ser dwelling units or sleeping units and are protected by an approved automatic sprinkler sy installed in accordance with Section 903.3.1.1 or 903.3.1.2, provided that dwelling uni sleeping units either have a means of egress door opening directly to an exterior exit ac that leads directly to the exits or are served by open-ended corridors designed in accord with Section 1026.6, Exception 4. (Add) 907.2.11.1.1 Group R-1 bed and breakfast establishments. An approved household fire war system in accordance with the requirements of NFPA 72, consisting of a control unit with smoke detec a manual fire alarm box on each floor and occupant notification, shall be installed in all Group R-1 be breakfast establishments. A heat detector shall be installed in the kitchen. (Add) 907.2.11.2.1 Group R-4. In Group R-4 occupancies, single- or multiple-station smoke alarms be installed in living rooms, dens, day rooms and similar spaces in addition to the locations require - pdf_text
3 3. Indicate the use and occupancy for which the proposed work is intended. - pdf_text
3 3. So that openings in exterior walls are flashed in accordance with Section R703.4. - pdf_text
3 3. Pursuant to section 29-252a of the Connecticut General Statutes, state agencies or the Connec Airport Authority shall not be required to obtain a certificate of occupancy from a local buil official. State agencies and the authority shall obtain a certificate of occupancy for constru work as described in section 29-252a of the Connecticut General Statutes from the State Buil Inspector. (Add) R110.1.1 Zoning approval. Pursuant to subsection (f) of section 8-3 of the Connecticut Ge Statutes, no certificate of occupancy shall be issued for a building, use or structure subject to the zo regulations of a municipality without certification in writing by the official charged with the enforce of such regulations that such building, use or structure is in conformity with such regulations or is a nonconforming use under such regulations. (Add) R110.1.2 Statement of professional opinion. Pursuant to section 29-276c of the Connec General Statutes, no certificate of occupancy shall be issued for a proposed structure or additio buildings classified as nontransient residential dwellings having more than 16 units or 24,000 square total gross area per building, until the building official has been provided with a statement signed b architect or professional engineer and the general contractor stating that the completed structure or add is in substantial compliance with the approved plans on file. - pdf_text
3 3. The outside fill pipe shall be removed, and the tank opening shall be capped or plugged o outside fill pipe shall be capped and filled with concrete, and all remaining piping, other tha vent line, shall be capped or sealed. (Add) M2201.7.3 Permanent abandonment of underground tanks. Underground tanks shal permitted to be permanently closed in place if the following requirements are met: - pdf_text
3 3 Chlorinated polyvinyl chloride (CPVC) pipe and tubing, 11/4 inches and larger - pdf_text
3 3. For occupancies in Group R-1 bed and breakfast establishments, in Group R-3, and w individual dwelling units in occupancies in Group R-2, where the top of the guard also serve handrail on the open sides of stairs, the top of the guard shall be not less than 34 inches (864 and not more than 38 inches (965 mm) measured vertically from a line connecting the lea edges of the treads. - pdf_text
3 3. On ramps and ramped aisles, from the ramp surface at the guard. Exceptions: - pdf_text
3 3. Basements without habitable spaces and having not more than 200 square feet (18.6 m floor area shall not be required to have emergency escape and rescue openings. - pdf_text
3 3 CPVC ≥ 11/4 inches - pdf_text
3 3. Portable cooling units. - pdf_text
3 3. Smoke partition. - pdf_text
3 3. Interior doors, where installed at the time of the test, shall be open. - pdf_text
3 3 dwelling and that is located on the same lot. (Amd) APPROVED AGENCY. An established and recognized agency that is regularly engag conducting tests, furnishing inspection services or furnishing product certification, where such agenc been approved by the building official. Officials certified in accordance with the provisions of sectio - pdf_text
3 3. Exit access stairways serving and contained within a Group R-3 congregate residence or a G R-4 facility are not required to be enclosed. - pdf_text
3 3. Buildings and structures for which heating and cooling is supplied solely by utilization of purchased renewable energy sources including, but not limited to, on-site wind, on-site wat on-site solar power, or wood-burning heating appliances that do not rely on backup heat from purchased, non-renewable sources. - pdf_text
3 3. ASCE Minimum Design Loads for Buildings and Other Structures (ASCE 7). - pdf_text
3 3. The combined area of all Group M fire areas on all floors, including any mezzanines, exc - pdf_text
3 3. Oil derricks. - pdf_text
3 3. Erecting on solid rock. Exception: Free-standing buildings or structures meeting all of the following conditions shall n required to be protected: - pdf_text
3 3. Luminaires for historic lighting on the premises of an historic building as defined in the International Existing Building Code or within a designated historic district. - pdf_text
3 3. Machine rooms, machinery spaces, control rooms and control spaces associated with occ evacuation elevators designed in accordance with Section 3008. (Add) 903.3.1.1.3 Vertical openings. Closely spaced sprinklers and draft stops are not required ar floor openings permitted to be unenclosed by this code unless the closely spaced sprinklers and draft s are being utilized in lieu of an enclosure as specified by Section 712.1.3.1. (Add) 903.3.5.3 Water authority approval. Unless served by a private well of sufficient capacity or approved source, domestic service shall be permitted to provide the water supply for the automatic spri system only upon written approval of the water authority supplying such domestic service. (Del) 903.5 Testing and maintenance. Delete section. (Add) 905.2.1 Piping design. The riser piping, supply piping and the water service piping shall be siz maintain a residual pressure of at least 100 pounds per square inch (psi) at the topmost outlet of each while flowing the minimum quantities of water specified based upon a pressure of 150 psi available a fire department connection. Exception: In buildings equipped throughout with an automatic sprinkler system in accordance - pdf_text
3 3. Corridor walls as required by Section 1020.1. - pdf_text
3 3. Pursuant to section 29-252a of the Connecticut General Statutes, state agencies or the Connec Airport Authority shall not be required to obtain a certificate of occupancy from a local buil official. State agencies or the authority shall obtain a certificate of occupancy for construction as described in section 29-252a of the Connecticut General Statutes from the State Buil Inspector. (Add) 111.1.1 Zoning approval. Pursuant to subsection (f) of section 8-3 of the Connecticut Ge Statutes, no certificate of occupancy shall be issued for a building, use or structure subject to the zo regulations of a municipality without certification in writing by the official charged with the enforce of such regulations that such building, use or structure is in conformity with such regulations or is a nonconforming use under such regulations. (Add) 111.1.2 Fire marshal approval. No certificate of occupancy, temporary certificate of occupa partial certificate of occupancy or certificate of approval for a building, structure or use subject t requirements of the Connecticut State Fire Safety Code shall be issued without certification in writing the local fire marshal that the building, structure or use is in substantial compliance with the requirem of the Connecticut State Fire Safety Code. - pdf_text
3 3 CPVC pipe or tubing (11/4 inches in diameter and larger) - pdf_text
3 3. An operable window complying with Section 310.7.1 shall be acceptable as an emergency es and rescue opening. - pdf_text
3 3. The riser height of spiral stairways shall be in accordance with Section R311.7.10.1. (Amd) R311.7.5.2 Treads. The minimum tread depth shall be 9 inches (229 mm). The tread depth be measured horizontally between the vertical planes of the foremost projection of adjacent treads and right angle to the tread’s leading edge. The greatest tread depth within any flight of stairs shall not ex the smallest by more than ⅜ inch (9.5 mm). Exception: The minimum tread depth of existing stairs serving existing unfinished attics or exi unfinished basements being converted to habitable space or replacement stairs within exi dwellings shall be 8 inches (203 mm), measured in accordance with Section R311.7.5.2. (Amd) R311.7.6 Landings for stairways. There shall be a floor or landing at the top and bottom of stairway. The width perpendicular to the direction of travel shall be not less than the width of the f served. For landings of shapes other than square or rectangular, the depth at the walk line and the total shall be not less than that of a quarter circle with a radius equal to the required landing width. Wher stairway has a straight run, the depth in the direction of travel shall be not less than 36 inches (914 m Exceptions: - pdf_text
3 3. A fabricator of precast concrete certified by the Precast/Prestressed Concrete Institute’s Certification Program, Groups C and CA. - pdf_text
3 3. A yard shall not be required to open directly into a public way where the yard opens t unobstructed path from the yard to the public way. Such path shall have a width of not less tha inches (914 mm). (Amd) R310.2.1 Minimum size. Emergency escape and rescue openings shall have a net clear openi not less than 5.7 square feet (0.530 m2). Exceptions: - pdf_text
3 3. The building contains more than 11 dwelling units or sleeping units. Exceptions: - pdf_text
3 3. Where the private garage connects to the building through an open-ended corridor. - pdf_text
3 3. Portable fuel-cell appliances that are not connected to a fixed piping system and are interconnected to a power grid. Mechanical: - pdf_text
3 3. Portable fuel cell appliances that are not connected to a fixed piping system and are interconnected to a power grid. Mechanical: - pdf_text
3 3. When the ratio of wall openings to exterior wall length in any story on any side of the buil increases by more than 5 percent. (Amd) R301.6 Roof load. Roofs shall be designed for the snow load indicated in Table R301.2(1). (Del) Table R301.6 – MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE F OF HORIZONTAL PROJECTION. Delete table in its entirety without substitution. (Add) R301.9 Ungraded lumber. Pursuant to section 29-256b of the Connecticut General Statutes, th of ungraded lumber is allowed in utility structures and low-risk structures. For the purposes of this se “utility structures” means accessory structures. (Add) R302.2.7 Sound transmission. Wall and floor-ceiling assemblies separating adjacent townh units shall comply with Appendix AK. - pdf_text
3 3. The contractor is permitted to employ the approved agencies where the contractor is also the o - pdf_text
3 3. Carbon monoxide detectors shall not be required in buildings not containing a fuel-bur appliance, fireplace or attached garage. (Add) 915.8 During construction. Pursuant to section 29-315b of the Connecticut General Statutes, whenever a single-family or two-family dwelling is occupied during interior alterations or additions requiring a building permit where a fuel-burning appliance, fireplace or attached garage exists, the temporary installation of battery-operated carbon monoxide alarms shall be required in the vicinity of such alterations or additions for the duration of construction activities. Combined smoke and carbon monoxide alarms may be installed to comply with Section 907.2.11.2.2.1 and this section. (Del) SECTION 918 - EMERGENCY RESPONDER RADIO COVERAGE. Delete section. CHAPTER 10 – MEANS OF EGRESS (Add) 1001.3 Means of egress. In addition to the requirements of this code, means of egress in existing buildings undergoing additions, alterations or repairs shall meet the requirements of the Connecticut State Fire Safety and Fire Prevention Codes for the proposed occupancy. (Add) 1003.8 Security device. Any security device or system that emits any medium that could obsc means of egress in any building, structure or premises is prohibited. - pdf_text
3 3. Spiral stairways in accordance with Section 1011.10. - pdf_text
3 3. Temporary testing systems required for the testing or servicing of electrical equipment or appar Gas: - pdf_text
3 3. All flammable and combustible liquids and residues shall be removed from the tank, appurtena and piping, and shall be disposed of in accordance with regulatory requirements and ind practices, using a written procedure. - pdf_text
3 3. Structural, plumbing and mechanical work shall conform to the requirements of this code (Add) 101.8 Gas. The International Fuel Gas Code is not adopted by the state of Connecticut. references to the International Fuel Gas Code within the body of this code shall be considered refere to requirements of NFPA 2, Hydrogen Technologies Code, NFPA 54, National Fuel Gas Code and N - pdf_text
3 3. Accessible toilet or bathing rooms where not all toilet or bathing rooms are accessible. - pdf_text
3 3. The load-carrying capacity of the roof of the adjacent existing building is capable of support the additional snow drift loads. Snow drift loads shall be derived in accordance with Section 7.7 of ASCE 7. (Add) 306.5.1 Complete change of occupancy. Where an entire building undergoes a chan occupancy, it shall comply with Section 306.5 and shall have all of the following accessible features: - pdf_text
3 3. The automatic sprinkler system is provided with a minimum 30-minute water supply, - pdf_text
3 3. Manual acts, including accidental opening of a switch controlling normal lighting facilities. - pdf_text
3 3. Where cooking or food warming of any type is not allowed in guestrooms, and - pdf_text
3 3. The load-carrying capacity of the roof of the adjacent existing building is capable of support the additional snow drift loads. Snow drift loads shall be derived in accordance with Section 7.7 of ASCE 7. (Del) Table 1608.2. Delete table. (Del) Figures 1608.2 (1) and (2). Delete figures. (Amd) 1609.3 Basic design wind speed. The basic design wind speed, V, in mph, for the determinat of the wind loads shall be determined by Appendix P. When required, the allowable stress design w speed, Vasd, shall be determined by Appendix P. (Del) Figures 1609.3(1) through 1609.3(12). Delete figures. (Del) Table 1609.3.1. Delete table. (Add) 1610.1.1 Seismic lateral earth pressure. Seismic lateral earth pressure loads on basement w and retaining walls for structures in Seismic Design Categories D through F shall be in accordance ASCE 7. Seismic lateral earth pressure loads on basement and retaining walls in Seismic Des Categories A through C need not be considered. (Amd) 1611.1 Design rain loads. Each portion of a roof shall be designed to sustain the load of rainw as per the requirements of Chapter 8 of ASCE 7, except the design rainfall shall be based on twice - pdf_text
3 3. Signage complying with Section 1112 of the International Building Code. - pdf_text
3 3. In air traffic control towers, an accessible route is not required to serve the cab and the immediately below the cab. - pdf_text
3 3. The structural members supporting the rated assemblies shall not be required to be fire-resist rated. (Amd) 310.3 Residential Group R-2. Residential Group R-2 occupancies containing sleeping uni more than two dwelling units where the occupants are primarily permanent in nature, including: Apartment houses Congregate living facilities (nontransient) with more than six occupants Boarding houses (nontransient) Convents Dormitories Fraternities and sororities Monasteries Hotels (nontransient) Live/work units Motels (nontransient) Vacation timeshare properties - pdf_text
3 3. Fire pump rooms. - pdf_text
3 3. Within dwelling units and sleeping units in Groups R-1, R-2 and R-3. - pdf_text
3 3. Alterations, additions or repairs to existing manufactured homes. The construction, altera moving, demolition, repair and use of accessory buildings and structures and their building se equipment shall comply with the requirements of the Connecticut State Building Code. These provisions shall not be applicable to the design and construction of manufactured homes and not be deemed to authorize either modifications or additions to manufactured homes where other prohibited. (Amd) AE120.1 General. The provisions of Sections AE121 to AE126, inclusive, are applicable only request of the building permit applicant with the approval of the local building official. (Amd) APPENDIX AF – PASSIVE RADON GAS CONTROLS (Amd) AF101.1 General. This appendix contains radon-resistant construction techniques for construction. (Del) FIGURE AF101.1 EPA MAP OF RADON ZONES. Delete figure. (Del) TABLE AF101.1 HIGH RADON-POTENTAIL (ZONE 1) Counties. Delete table. (Add) AF101.2 Radon mitigation preparation construction technique. All newly constructed deta one- and two-family dwellings and townhouses shall be provided with radon mitigation prepar construction in accordance with Section AF105 of this code. Exceptions: - pdf_text
3 3. Installation, alteration or repairs of mechanical systems that are not fuel-fired. - pdf_text
3 3. The following shall be permitted to be constructed in accordance with this code where provided a residential fire sprinkler system complying with Section P2904: - pdf_text
3 3. A child-height lavatory. (Add) 1110.2.4.1 Pull handle. Where accessible water closet compartments or single-occupancy rooms are provided, the compartment or room doors shall have a pull handle mounted 6 inches fro hinge side on the compartment or room side of the door. This handle shall meet the requirements of Se - pdf_text
3 3. In lounges, recreation areas and sleeping rooms in the day care facilities. Exception: Day care facilities housed in one room. (Del) 907.6.6.3 Termination of monitoring service. Delete section. (Add) 907.6.6.3 Automatic telephone-dialing devices. Automatic telephone-dialing devices use transmit an emergency alarm shall comply with the requirements of subsection (c) of section 28-25b o Connecticut General Statutes. (Del) 907.8 Inspection, testing and maintenance. Delete section. (Add) 913.6 Electric fire pumps. Buildings provided with standby electrical power for the purpo continuing operations or occupancy shall provide standby power in accordance with Article 701 of N - pdf_text
3 3. Where multiple single-user toilet rooms or bathing rooms are clustered at a single location, at - pdf_text
3 3. Group E occupancies. In Group E occupancies, emergency escape and rescue openings sha provided in every room or space greater than 250 square feet used for classroom or educati purposes or normally subject to student occupancy. Exceptions: - pdf_text
3 3. Where an incline platform lift or stairway chairlift is installed on a stairway within a dwelling a clear passage width not less than 20 inches (508 mm) shall be provided. If the seat and plat can be folded when not in use, the distance shall be measured from the folded position. (Amd) R311.7.2 Headroom. The minimum headroom in all parts of the stairway shall not be less th feet 8 inches (2032 mm) measured vertically from the sloped line adjoining the tread nosing or fro floor surface of the landing or platform on that portion of the stairway. - pdf_text
3 (cont. 2) (Add) 111.1.3 Statement of professional opinion. Pursuant to section 29-276c of the Connecticut Ge Statutes, no certificate of occupancy shall be issued for a proposed structure or addition to build classified as (1) assembly, educational, institutional, high-hazard, transient residential, which incl hotels, motels, rooming or boarding houses, dormitories or similar buildings, other than reside buildings designed to be occupied by one or more families, without limitation as to size or numb stories; (2) business, factory and industrial, mercantile, moderate and low-hazard storage, having t stories or more or exceeding 30,000 square feet total gross area; and (3) nontransient residential dwell having more than 16 units or 24,000 square feet total gross area per building, until the building officia - pdf_text
3 (cont. 2) (Amd) R110.4 Temporary occupancy. The building official may issue a temporary certificat occupancy before the completion of the entire work covered by the permit, provided such portio portions shall be occupied safely prior to full completion of the building or structure without endang life or public welfare. Any occupancy permitted to continue during completion of the work shal discontinued within 30 days after completion of the work unless the building official issues a certifica occupancy. No temporary certificate of occupancy shall be issued for work subject to the zoning regulat of a municipality without certification in writing by the official charged with the enforcement of regulations that the work is in conformity with such regulations or is a valid nonconforming use under regulations. - pdf_text
3 (cont. 2) (Amd) 1004.5 Areas without fixed seating. The number of occupants shall be computed at the rate o one occupant per unit of area as prescribed in Table 1004.5. For areas without fixed seating, the occu load shall be not less than the number determined by dividing the floor area under consideration by th occupant load factor assigned to the function of the space as set forth in Table 1004.5. Where an inte function is not listed in Table 1004.5, the building official shall establish a function based on a listed function that most nearly resembles the intended function. (Amd) 1005.3.1 Stairways. The capacity, in inches, of means of egress stairways shall be calculate multiplying the occupant load served by such stairways by a means of egress capacity factor of 0.3 (7.6 mm) per occupant. Where stairways serve more than one story, only the occupant load of each considered individually shall be used in calculating the required capacity of the stairways serving that s Exceptions: - pdf_text
3 (cont. 2) (Add) 2603.1.1.1 Foamed-in-place insulating material. Pursuant to section 29-277 of the Connec General Statutes, foamed-in-place insulating material, except urethane foam insulation or styrene f insulation, shall not be sold or installed in this state on or after May 28, 2013, unless the manufactur supplier has certified to the State Building Inspector that the material complies with the provisions of section. CHAPTER 27 – ELECTRICAL (Add) 2702.2.20 Electric fire pumps. Buildings provided with standby electrical power for the purpo continuing operations or occupancy shall provide standby power in accordance with Article 701 o National Electrical Code for any electric fire pump installed to provide an adequate water suppl minimum operating pressure to a required automatic sprinkler system. (Amd) 2702.4 Maintenance. Emergency and standby power systems shall be maintained and teste accordance with the Connecticut State Fire Prevention Code. - pdf_text
3 (cont. 3) (Add) R110.6 Partial occupancy. The building official may issue a partial certificate of occupancy portion of the building or structure when, in the building official’s opinion, the portion of the buildi be occupied is in substantial compliance with the requirements of this code and no unsafe conditions in portions of the building not covered by the partial certificate of occupancy that are accessible fro occupied portion. No partial certificate of occupancy shall be issued for work subject to the zo regulations of a municipality without certification in writing by the official charged with the enforce of such regulations that the work is in conformity with such regulations or is a valid nonconforming under such regulations. (Add) R110.7 Prefabricated assemblies. A certificate of approval by an approved agency shal furnished with every prefabricated assembly, including modular housing, except where all elements o assembly are readily accessible for inspection at the site. The building official shall inspect placeme prefabricated assemblies and the connections to public utilities and private water and septic systems a building site, as well as any site-built or installed components or equipment to determine compliance this code. A final inspection shall be provided in accordance with Section R109.1.6. - pdf_text
3.1 3.1. Live/work units located in townhouses and complying with the requirements of Section 4 the 2021 International Building Code portion of the 2022 Connecticut State Building Co - pdf_text
3.2 3.2. Owner-occupied lodging houses with five or fewer guestrooms. - pdf_text
3.3 3.3. A care facility with three or fewer persons receiving medical care within a dwelling unit. (Add) R101.4 Referenced codes and regulations. (Add) 101.4.1 Gas. The International Fuel Gas Code is not adopted by the state of Connecticut. references to the International Fuel Gas Code within the body of this code shall be considered refere to requirements of NFPA 2, Hydrogen Technologies Code; NFPA 54, National Fuel Gas Code; and N - pdf_text
30 30 Yes Sterling - pdf_text
30 30 Yes North Stonington - pdf_text
30 30 days after completion of the work unless a certificate of occupancy is issued by the building offi No temporary certificate of occupancy shall be issued for work subject to the zoning regulations municipality without certification in writing by the official charged with the enforcement of regulations that the work is in conformity with such regulations or is a valid nonconforming use under regulations. (Add) 111.5 Partial occupancy. The building official may issue a partial certificate of occupancy portion of the building or structure when, in the building official’s opinion, the portion of the buildi be occupied is in substantial compliance with the requirements of this code and no unsafe conditions in the portion of the building not covered by the partial certificate of occupancy. No partial certifica occupancy shall be issued for work subject to the zoning regulations of a municipality without certific in writing by the official charged with the enforcement of such regulations that the work is in confor with such regulations or is a valid nonconforming use under such regulations. - pdf_text
30 30 Yes North Canaan - pdf_text
30 30 Yes Union - pdf_text
30 30 Yes Colebrook - pdf_text
30 30 Yes Old Lyme - pdf_text
30 30 Yes Oxford - pdf_text
30 30 Yes Goshen - pdf_text
30 30 Yes Mansfield - pdf_text
30 30 Yes Groton - pdf_text
30 30 Yes Stratford - pdf_text
30 30 Yes Winchester - pdf_text
30 30 Yes Chester - pdf_text
30 30 Yes Derby - pdf_text
30 30 Yes Brooklyn - pdf_text
30 30 Yes Branford - pdf_text
30 30 Yes Newtown - pdf_text
30 30 Yes Sherman - pdf_text
30 30 Yes East Lyme - pdf_text
30 30 Yes Ellington - pdf_text
30 30 Yes Bolton - pdf_text
30 30 Yes Weston - pdf_text
30 30 Yes Montville - pdf_text
30 30 Yes Norfolk - pdf_text
30 30 Yes Haddam - pdf_text
30 30 Yes Hartland - pdf_text
30 30 Yes Manchester - pdf_text
30 30 Yes Ashford - pdf_text
30 30 Yes Hampton - pdf_text
30 30 Yes Monroe - pdf_text
30 30 Yes Glastonbury - pdf_text
30 30 Yes East Hampton - pdf_text
30 30 Yes Farmington - pdf_text
30 30 Yes Watertown - pdf_text
30 30 Yes Preston - pdf_text
30 30 Yes Meriden - pdf_text
30 30 Yes New Milford - pdf_text
30 30 Yes Woodbury - pdf_text
30 30 Yes Seymour - pdf_text
30 30 Yes Windsor Locks - pdf_text
30 30 Yes Plainfield - pdf_text
30 30 Yes Sprague - pdf_text
30 30 Yes Deep River - pdf_text
30 30 Yes New London - pdf_text
30 30 Yes Durham - pdf_text
30 30 Yes Norwich - pdf_text
30 30 Yes Middletown - pdf_text
30 30 Yes Middlebury - pdf_text
30 30 Yes Wethersfield - pdf_text
30 30 Yes Sharon - pdf_text
30 30 Yes Wallingford - pdf_text
30 30 Yes Cromwell - pdf_text
30 30 Yes West Haven - pdf_text
30 30 Yes Plainville - pdf_text
30 30 Yes Norwalk - pdf_text
30 30 Yes Voluntown - pdf_text
30 30 Yes Southbury - pdf_text
30 30 Yes Orange - pdf_text
30 30 Yes East Hartford - pdf_text
30 30 Yes Warren - pdf_text
30 30 Yes Hamden - pdf_text
30 30 Yes Westport - pdf_text
30 30 Yes East Haven - pdf_text
30 30 Yes Windsor - pdf_text
30 30 Yes Griswold - pdf_text
30 30 Yes Bridgeport - pdf_text
30 30 Yes Putnam - pdf_text
30 30 Yes Lisbon - pdf_text
30 30 Yes Guilford - pdf_text
30 30 Yes Rocky Hill - pdf_text
30 30 Yes Suffield - pdf_text
30 30 Yes Ansonia - pdf_text
30 30 Yes Morris - pdf_text
30 30 Yes Litchfield - pdf_text
30 30 Yes Ledyard - pdf_text
30 30 Yes Bethel - pdf_text
30 30 Yes Salisbury - pdf_text
30 30 Yes Kent - pdf_text
30 30 Yes Canton - pdf_text
30 30 Yes Milford - pdf_text
30 30 Yes Clinton - pdf_text
30 30 feet (9144 mm). This category includes flat open country and grasslands. Surface Roughness D. Flat, unobstructed areas and water surfaces. This category includes smooth mud flats, salt flats and unbroken ice. (Add) R301.2.1.4.3 Exposure categories. An exposure category shall be determined in accordance with the following: Exposure B. For buildings with a mean roof height of less than or equal to 30 feet (9144 m Exposure B shall apply where the ground surface roughness, as defined by Surface Roughness prevails in the upwind direction for a distance of at least 1,500 feet (457 m). For buildings with a m roof height greater than 30 feet (9144 mm), Exposure B shall apply where Surface Roughnes prevails in the upwind direction for a distance of at least 2,600 feet (792 m) or 20 times the heigh the building, whichever is greater. Exposure C. Exposure C shall apply for all cases where Exposure B or D does not apply. - pdf_text
30 30 Yes Eastford - pdf_text
30 30 Yes Bethlehem - pdf_text
30 30 Yes Old Saybrook - pdf_text
30 30 Yes Westbrook - pdf_text
30 30 Yes Prospect - pdf_text
30 30 Yes East Granby - pdf_text
30 30 Yes Ridgefield - pdf_text
30 30 Yes New Canaan - pdf_text
30 30 Yes New Fairfield - pdf_text
30 30 Yes Bethany - pdf_text
30 30 Yes Danbury - pdf_text
30 30 Yes Darien - pdf_text
30 30 Yes Lebanon - pdf_text
30 30 - New Hartford - pdf_text
30 30 Yes Willington - pdf_text
30 30 Yes Stafford - pdf_text
30 30 Yes Bridgewater - pdf_text
30 30 Yes Berlin - pdf_text
30 30 Yes Madison - pdf_text
30 30 Yes Colchester - pdf_text
30 30 Yes New Britain - pdf_text
30 30 Yes Cornwall - pdf_text
30 30 Yes Bozrah - pdf_text
30 30 Yes Fairfield - pdf_text
30 30 Yes Roxbury - pdf_text
30 (cont. 2) (Add) 111.6 Certificate of approval. The building official shall issue a certificate of approval indic substantial compliance with the requirements of this code for all completed work that requires a buil permit but does not require a certificate of occupancy. Such work shall include, but not be limited to: fe greater than 7 feet (2134 mm) in height; retaining walls greater than 3 feet (914 mm) in height; d garages; swimming pools; basements and attics converted to habitable space; and electrical, plumbing, mechanical repairs or alterations. No certificate of approval shall be issued for work subject to the zo regulations of a municipality without certification in writing by the official charged with the enforce of such regulations that the work is in conformity with such regulations or is a valid nonconforming under such regulations. - pdf_text
304.2.1 304.2.1 or 304.2.2. Exception: Pools located in riverine flood hazard areas which are outside of designated flood (Amd) 305.1.1 Construction fencing required. A temporary enclosure shall be installed for in gr swimming pools and spas from the time that construction occurs up to the time that the permanent b is completed. The temporary enclosure shall be a minimum of 4 feet (1219) in height, shall hav openings that will allow passage of a 4-inch (102 mm) sphere and shall be equipped with a positive latc device on any openings. (Amd) 305.2.9 Clear Zone. The required barrier height shall exist around the entire perimeter of the barrier and for a distance of 3 feet (914 mm) measured horizontally from the outside of the required barrier, free of structures, equipment or similar objects. (Amd) 305.6 Natural barriers. In the case where the pool or spa area abuts the edge of a lake or natural body of water, public access is not permitted or allowed along the shoreline, and required ba extend to and beyond the water’s edge not less than 18 inches (457 mm), a barrier is not required bet the natural body of water shoreline and the pool or spa when approved by the State Building Inspecto - pdf_text
304.2.1 (cont. 2) (Amd) 305.7 Natural topography. Natural topography that prevents direct access to the pool or spa shall include but not be limited to mountains and natural rock formations. A natural barrier approv the State Building Inspector shall be acceptable provided that the degree of protection is not less tha protection afforded by the requirements of Sections 305.2 through 305.5. (Del) SECTION 306 DECKS. Delete section in its entirety. (Del) 307.1.2 Colors and finishes. Delete section and subsections in their entirety. (Del) 307.2.4 Surface conditions. Delete section in its entirety. (Del) SECTION 308 DIMENSIONAL DESIGN. Delete section in its entirety. (Amd) 311.3 Water velocity. The water velocity in suction and return piping For residential pools and shall not exceed 8 fps (2.4 mps). All water velocity calculations shall be based on the design flow specified for each recirculation system. (Del) 311.6 Pressure or vacuum gauge. Delete section in its entirety. (Del) 311.7 Flow measurement. Delete section in its entirety. (Del) 313.7 Emergency shutoff switch. Delete section in its entirety. (Del) SECTION 318 WATER SUPPLY. Delete section in its entirety. (Del) SECTION 319 SANITIZING EQUIPMENT. Delete section in its entirety. (Del) 321.2 Artificial lighting required. Delete section and subsections in its entirety. (Del) 321.3 Emergency illumination. Delete section in its entirety. - pdf_text
3103.5.5.4 3103.5.5.4 shall comply with the structural stability requirements of that section. (Add) 3103.5.4 Location. Tents or membrane structures shall not be located within 20 feet (6096 m lot lines, buildings, other tents or membrane structures, parked vehicles, or internal combustion eng For the purpose of determining required distances, support ropes and guy wires shall be considered as of the temporary membrane structure or tent. Exceptions: - pdf_text
318a 318a, 29-318b and 29-318c of the Connecticut General Statutes, and the regulations adopted b Commissioner of Consumer Protection under authority of section 29-318c of the Connecticut Ge Statutes. CHAPTER 29 – PLUMBING SYSTEMS (Amd) 2901.1 Scope. The provisions of this chapter and the International Plumbing Code shall gover design, construction, erection and installation of plumbing components, appliances, equipment and sys used in buildings and structures covered by this code. Toilet and bathing rooms shall be construct accordance with Section 1210. The International Plumbing Code shall govern the use and maintenan plumbing components, appliances, equipment and systems. The International Existing Building Code the International Plumbing Code shall govern the alteration, repair, relocation, replacement and add of plumbing components, appliances, equipment and systems. (Add) 2901.2 Private sewage disposal systems. Private sewage disposal systems shall be designed installed in accordance with the Public Health Code adopted under authority of section 19a-36 o Connecticut General Statutes. Approval of such systems shall be by the local authority having jurisdic When such approval is required by the local authority having jurisdiction, written proof of such appr shall be submitted to the building official prior to issuance of a building permit. - pdf_text
318a (cont. 2) (Amd) 2902.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum nu shown in Table 2902.1 based on the actual use of the building or space. Uses not shown in Table 2 shall be considered individually by the building official. The number of occupants shall be determin this code. - pdf_text
333 333 Pfingsten Road Northbrook, IL 60062 (Amd) UL/CSA 60335-2-40—2019 Standard for Household and Similar Electrical Appliances, Part 2: Requirements for Motor-compress M1402.1, M1412.1, M1413.1, M2006.1 - pdf_text
35 35 Yes Killingworth - pdf_text
35 35 Yes South Windsor - pdf_text
35 35 Yes Southington - pdf_text
35 35 Yes Torrington - pdf_text
35 35 Yes East Haddam - pdf_text
35 35 Yes Bloomfield - pdf_text
35 35 Yes Burlington - pdf_text
35 35 Yes Waterford - pdf_text
35 35 Yes Cheshire - pdf_text
35 35 Yes Stonington - pdf_text
35 35 Yes Pomfret - pdf_text
35 35 Yes Hebron - pdf_text
35 35 Yes Plymouth - pdf_text
35 35 Yes Salem - pdf_text
35 35 - Beacon Falls - pdf_text
35 35 Yes Wilton - pdf_text
35 35 Yes Woodbridge - pdf_text
35 35 Yes Marlborough - pdf_text
35 35 Yes Greenwich - pdf_text
35 35 Yes Hartford - pdf_text
35 35 Yes Franklin - pdf_text
35 35 Yes Essex - pdf_text
35 35 Yes Thomaston - pdf_text
35 35 Yes Wolcott - pdf_text
35 35 Yes Enfield - pdf_text
35 35 Yes Chaplin - pdf_text
35 35 Yes Woodstock - pdf_text
35 35 Yes West Hartford - pdf_text
35 35 Yes Brookfield - pdf_text
35 35 Yes Middlefield - pdf_text
35 35 Yes Stamford - pdf_text
35 35 Yes Avon - pdf_text
35 35 Yes Barkamsted - pdf_text
35 35 Yes Canaan - pdf_text
35 35 Yes Somers - pdf_text
37d 37d of the Connecticut General Statutes: (a) Any person engaged in the installation of an irrigation system or other physical connection between the distribution system of a public water supply system and any other water system s notify the water company servicing the property or building of such installation and shall be subject to all applicable rules and regulations of such water company. For purposes of this section, "water company" has the same meaning as provided in section 25-32a of the Connec General Statutes. (b) When a permit application is filed with the local building inspector of any municipality concerning any project that includes a change of use or installation of fixtures or facilities in building that may affect the performance of, or require the installation of, a reduced pressure principle backflow preventer, a double check valve assembly or a pressure vacuum breaker, t - pdf_text
4 4 Aluminum tubing - pdf_text
4 4 Cross-linked polyethylene/aluminum/crosslinked polyethylene (PEX-AL-PEX) pipe smaller than 1 inch - pdf_text
4 4. Where a carbon monoxide detector is provided in an approved location between openings private garage and dwelling units or sleeping units. (Amd) 915.2.3 Group E occupancies. Carbon monoxide detection systems shall be provided i locations specified in Sections 915.2.3.1 and 915.2.3.2. Exception: Group E rooms with cooking appliances, laboratories and maintenance spaces. (Add) 915.2.3.1 Locations. Carbon monoxide detectors shall be located as follows: - pdf_text
4 4. Where a two-story building or facility has one story or mezzanine with an occupant load of fi fewer persons that does not contain public use space, that story or mezzanine shall not be req to be connected by an accessible route to the story above or below. (Add) 1105.1.1.1 Automatic entrances. Where controls for automatic doors are provided, they shall an accessible location within 10 feet of the entrance. (Add) 1105.1.1.2 Primary entrances. Pursuant to section 29-270a of the Connecticut General Statut least one primary entrance to any covered mall building, anchor store or retail business (Group M) more than 50,000 square feet of floor space shall be equipped with an automatically operating door or d in sequence, installed in accordance with applicable provisions of this code. Exception: Nothing in this section shall require the installation of an automatically operating do a primary entrance which is open and unobstructed by any door during the hours that the retail busi is open to the public. (Add) 1106.2.1 Automobile accessible parking spaces. Pursuant to subsection (h) of section 14-25 the Connecticut General Statutes, parking spaces for passenger motor vehicles designated for persons are blind and persons with disabilities shall be as near as possible to a building entrance or walkway shall be 15 feet wide, including 5 feet of cross hatch. - pdf_text
4 4 dwelling or sleeping units are being added, the requirements of Section 1108 for Type B units and Ch - pdf_text
4 4. Inspect Shear Walls and Diaphragms a. Panel grade and thicknessb X b. Fastener size, length and spacing X c. Framing member sizes at panel edges X d. Blocking at panel edges X e. Field gluing X f. High-load diaphragms X - pdf_text
4 4. The footing for the grade-level termination of stairs or ramps attached to decks or landings, wh the deck or landing is supported by a dwelling or not, shall only be required to be placed at lea inches (305 mm) below the undisturbed ground surface in accordance with Section R403.1.4. (Add) R404.4.1 Guards. Retaining walls with a difference in height between the finished grade at th of the wall and the finished grade at the bottom of the wall that is greater than 4 feet (1219 mm) sha provided with guards complying with Sections R312.1.2 and R312.1.3 where there is a walking sur parking lot or driveway on the high side located closer than 2 feet (610 mm) to nearest side of the reta wall. For the purpose of this section, grass, planting beds or landscaped areas shall not be a walking sur (Add) R404.6 Deep foundations. Deep foundations shall comply with the requirements set forth in Se - pdf_text
4 4. Be accompanied by construction documents and other information as required in Section 107 - pdf_text
4 4. Habitable basements without sleeping rooms are not required to have emergency escape and re openings when they are provided with two remote, code-compliant stairways. (Amd) R311.3.1 Floor elevations at the required egress doors. Landings or finished floors at the req egress door shall not be more than 1½ inches (38 mm) lower than the top of the threshold. Exception: The landing or floor on the exterior side shall not be more than 8¼ inches (209.5 below the top of the threshold provided the door does not swing over the landing or the floor. Where exterior landings or floors serving the required egress door are not at grade, they shall be prov with access to grade by means of a ramp in accordance with Section R311.8 or a stairway in accord with Section R311.7. (Amd) R311.3.2 Floor elevations for other exterior doors. Doors other than the required egress shall be provided with landings or floors not more than 8¼ inches (209.5 mm) below the top o threshold. Exception: A landing is not required where a stairway of three or fewer risers, including the top from the dwelling to the top tread, is located on the exterior side of the door, provided the door not swing over the stairway. - pdf_text
4 4. Where parking is provided within or beneath a building, accessible parking spaces shall als provided within or beneath the building. Exception: Private parking garages within or beneath the building that contain no more than parking spaces, that are reserved for the exclusive use of a specific dwelling unit and are dir accessed from that dwelling unit are not required to be accessible. (Amd) 1106.6 Van spaces. For every six or fraction of six accessible parking spaces, at least one sha a van-accessible parking space. Each public parking garage or terminal shall have a minimum of two accessible parking spaces complying with this section. Exception: In Group U private garages that serve R-2 and R-3 occupancies, van-accessible sp shall be permitted to have vehicular routes, entrances, parking spaces and access aisles with a mini vertical clearance of 7 feet (2134 mm). (Add) 1106.6.1 Van accessible parking spaces. Pursuant to subsection (h) of section 14-253a o Connecticut General Statutes, parking spaces for passenger vans designated for persons who are blind persons with disabilities shall be as near as possible to a building entrance or walkway and shall be 16 wide, including 8 feet of cross hatch. - pdf_text
4 4. Water tanks supported directly upon grade if the capacity does not exceed 5,000 gallons (18 L) and the ratio of height to diameter or width does not exceed 2 to 1. - pdf_text
4 4. Containing 150,000 square feet of total gross floor area; Exception: For Group S (Storage) the limit shall be 250,000 total gross square feet. - pdf_text
4 4. Within sleeping units of Group I occupancies. - pdf_text
4 4 PEX tubing ≤ 1 inch - pdf_text
4 4. Exit access stairways connecting the first and second floors of Group R-1 bed and brea establishments. Stairways connecting the second and third floors in such occupancies sha enclosed with fire separation assemblies having a fire-resistance rating of not less than 1 Stairways connecting the basement and the first floor occupancies shall be enclosed with partitions having a fire-resistance rating of not less than ½ hour with 20-minute fire-resist rated door assemblies. Fire-resistance assemblies at stairways in Group R-1 bed and brea establishments shall not be required to be supported by fire-resistance-rated construction. - pdf_text
4 4. The tank, appurtenances, and piping shall be made safe by either purging them of flammable v or inerting the potential explosive atmosphere. Confirmation that the atmosphere in the tank is shall be by testing of the atmosphere using a combustible gas indicator if purging, or an ox meter if inerting, at intervals in accordance with written procedures. - pdf_text
4 4. If treated, the date the fabric or material was last treated with flame-retardant solution, the name or kind of chemical used in treatment, name of person or firm treating the fabric or mat and name of testing agency and test standard by which the fabric or material was tested. - pdf_text
4 4. Exterior or interior terminations for continuous ventilation systems shall be closed or sealed. - pdf_text
4 4. For occupancies in Group R-1 bed and breakfast establishments, level guards shall be not than 36 inches (914 mm) high, measured vertically above the adjacent walking surface. - pdf_text
4 4. Buildings or structures that are capable of supporting the design snow loads, including snow effects, as required by the International Building Code for new structures. A statement fr professional engineer shall be provided as confirmation of this exception. (Amd) 304.2 Snow loads on adjacent buildings. If an alteration or addition is located within 20 feet ( m) of an adjacent existing building, and the alteration or addition exceeds the height of the adja existing building, a statement from a professional engineer confirming compliance with one or mor the following shall be provided: - pdf_text
4 4. That has a maximum of three stories in height and does not contain a mixed occupancy. (Add) HOTEL. Any building containing six or more guestrooms, intended or designed to be used, or w are used, rented or hired out to be occupied or which are occupied for sleeping purposes by guests. (Amd) HURRICANE-PRONE REGIONS. Areas within municipalities as tabulated in Appendix P. - pdf_text
4 4 Cross-linked polyethylene/aluminum/crosslinked polyethylene (PEX-AL- PEX) pipe smaller than 1 inch - pdf_text
4 4. Outdoor sports facility lighting of the participant sport area. - pdf_text
4 4. Beams and girders spaced apart not less than 36 inches (914 mm) in clear finished width project not more than 78 inches (1981 mm) from the finished floor. (Amd) R309.1 Floor surface. Garage floor surfaces shall be of approved noncombustible material. area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the move of liquids to an approved drain or toward the main vehicle entry doorway. Exception: Detached garages that are separated from the dwelling by a minimum distance of 10 (3048 mm). (Amd) R310.1 Emergency escape and rescue openings required. Habitable spaces located w basements, habitable spaces located in attics and every sleeping room shall have not less than one oper emergency escape and rescue opening. Where basements and attics contain one or more sleeping ro emergency egress and rescue openings shall be required in each sleeping room, but shall not be req in adjoining habitable areas of the basement or attic. Emergency escape and rescue openings shall directly into a public way, or to a yard or court that opens to a public way. Exceptions: - pdf_text
4 4. Smoke barrier. - pdf_text
4 4. Thermal factor, Ct. - pdf_text
4 4. Horizontal additions containing a newly introduced Group R occupancy that are added to exi buildings shall be required to have an automatic sprinkler system installed in the addition o the addition is completely separated from the existing building by fire barriers with a minimu hour fire-resistance rating. - pdf_text
4 4. Accessible entrances where not all entrances are accessible. - pdf_text
4 4. Accessible parking complying with Section 1106 of the International Building Code, where pa is being provided. - pdf_text
4 4. Throughout stories below the level of exit discharge where such stories have an area excee - pdf_text
4 4. So as to protect the potable water supply in accordance with Section P2902. - pdf_text
4 4 Polypropylene (PP) pipe or tubing (1 inch and smaller) - pdf_text
4 4. Where no more than one urinal is provided in a toilet room or bathing room, the urinal i required to be accessible. - pdf_text
4 4. That is a maximum of three stories in height and does not contain a mixed occupancy. (Add) 310.2.1.1 Kitchens in Group R-1 bed and breakfast establishments. Kitchens in Group R- and breakfast establishments shall be separated by ½-hour-rated fire separation assemblies. Exceptions: - pdf_text
4 4. The material is composed of materials that, in the form and thickness used, neither exhibit a f spread index greater than 25 nor evidence of continued progressive combustion when test accordance with ASTM E 84 or ANSI/UL 723 and are of such composition that all surfaces would be exposed by cutting through the material on any plane would neither exhibit a flame sp index greater than 25 nor exhibit evidence of continued progressive combustion when test accordance with ASTM E 84 or ANSI/UL 723. (Amd) REGISTERED DESIGN PROFESSIONAL. An individual who is registered or licensed b Department of Consumer Protection pursuant to chapters 390, 391, 396 or 396a of the Connecticut Ge Statutes to practice the individual’s respective design profession and acting within the scope of his o license and practice discipline. CHAPTER 3 - GENERAL REGULATIONS (Amd) 301.1 Scope. Except as may be otherwise regulated by Chapters 540 and 541 of the Connec General Statutes, or regulations of other state agencies, this chapter shall govern the approval installation of all equipment and appliances that comprise parts of the building mechanical sys regulated by this code in accordance with Section 101.2. (Amd) 301.6 Gas. The International Fuel Gas Code is not adopted by the state of Connecticut. references to the International Fuel Gas Code within the body of this code shall be considered refere to requirements of NFPA 2, Hydrogen Technologies Code, NFPA 54, National Fuel Gas Code and N - pdf_text
4 4. In areas that are not open to the public within occupancies in Group I-3, F, H or S, an alternating tread devices and ships ladders, guards shall not have openings which allow pas of a sphere 21 inches (533 mm) in diameter. - pdf_text
4 4 Stainless steel drainage systems - pdf_text
4 4. Steam, hot- or chilled-water piping contained within any heating or cooling equipment regu by Chapters 18 to 24, inclusive, of this code. - pdf_text
4 4. All habitable, enclosed usable areas and closets shall be sprinklered, - pdf_text
4 4. A fabricator of cold-formed steel trusses certified by the Structural Building Components Res Institute (SBCRI) TPI Third Party Quality Assurance Program. - pdf_text
4 4 Aluminum pipe and tubing - pdf_text
4 4. Changes in room floor elevations of three or fewer risers within dwelling units and sleeping uni Group R-1 bed and breakfast establishments and Groups R-2 and R-3 occupancies do not re handrails. - pdf_text
4 4. Aisle stairs in assembly seating areas where the stair pitch or slope is set, for sightline reason the slope of the adjacent seating area in accordance with Section 1029.13. - pdf_text
4 4 PEX tubing 1 inch and smaller - pdf_text
4 4. Storm shelters are not required to comply with this section where the shelter is construct accordance with ICC 500. - pdf_text
4 4. AISI Standard for Cold-Formed Steel Framing - Prescriptive Method For One- and Two-Fa Dwellings (AISI S230). - pdf_text
4 4 Cross-linked polyethylene/aluminum/cross-linked polyethylene (PEX-AL- PEX) pipe smaller than 1 inch - pdf_text
4 4 Steel pipe - pdf_text
4 4. Enclosed elevator lobby separation as required by Section 3006.2. - pdf_text
4 4 Lead pipe Continuous PB pipe or tubing - pdf_text
4 4 Copper or copper-alloy pipe - pdf_text
4 4 Polypropylene (PP) pipe or tubing, 1 inch and smaller - pdf_text
4 4. In other existing buildings and structures only if the State Building Inspector approves installation. Lifts shall comply with ICC A117.1 and shall be installed in accordance with ASME A18.1. Li use/limited application elevators shall comply with ICC A117.1 and shall be installed in accordance the Connecticut Safety Code for Elevators and Escalators adopted under authority of section 29-192 o Connecticut General Statutes. (Amd) 306.7.10.1 Accessible dwelling or sleeping units. Where Group I-1, I-2, I-3, R-1, R-2 or dwelling or sleeping units are being altered or added, the requirements of Section 1108 for Accessible and Chapter 9 for visible alarms of the International Building Code apply only to the quantity of s being altered or added. (Amd) 306.7.10.2 Type A dwelling or sleeping units. Where more than 20 Group R-2 dwelling or slee units are being altered or added, the requirements of Section 1108 for Type A units and Chapter 9 for vi alarms of the International Building Code apply only to the quantity of spaces being added or altered. (Amd) 306.7.10.3 Type B dwelling or sleeping units. Where four or more Group I-1, I-2, R-2, R-3, - pdf_text
4 4. Erected on solid rock. Footings shall not bear on frozen soil unless the frozen condition is permanent. Exceptions: - pdf_text
4 4 Cross-linked polyethylene/aluminum/cross-linked polyethylene (PEX- AL-PEX) pipe smaller than 1 inch - pdf_text
4 4. Group I-4 occupancies. In Group I-4 occupancies, emergency escape and rescue openings sha provided in every room or space greater than 250 square feet normally subject to client occupa Exceptions: - pdf_text
4 4. Steam, hot or chilled water piping within any heating or cooling equipment regulated by this - pdf_text
4 4. Generator rooms. - pdf_text
4 4. Electrical wiring, devices, appliances, apparatus or equipment operating at less than 25 volt not capable of supplying more than 50 watts of energy. - pdf_text
4 4. The contractor is permitted to employ the approved agencies for the verification of the temp installation restraint/bracing required for cold-formed steel trusses in Section 1705.2.4 and m plate connected wood trusses in Section 1705.5.2. (Amd) 1704.2.4 Report requirement. Approved agencies shall keep records of special inspections tests. The approved agency shall submit reports of special inspections and tests to the building officia to the registered design professional in responsible charge. Reports shall indicate that work inspect tested was or was not completed in conformance to approved construction documents. Discrepancies be brought to the immediate attention of the contractor for correction. If they are not corrected discrepancies shall be brought to the attention of the building official and to the registered d professional in responsible charge prior to the completion of that phase of the work. A final repo inspections documenting completion of all required special inspections and tests and correction of discrepancies noted in the inspections or tests shall be submitted prior to the issuance of the certifica occupancy. Interim reports shall be submitted periodically at the frequency agreed upon by the p applicant and the building official prior to the start of work. - pdf_text
4 4. Retaining walls that are not higher than 3 feet (914 mm) measured from finished grade at the bo of the wall to finished grade at the top of the wall, unless supporting a surcharge or impoun Class I, II or III-A liquids. - pdf_text
4 4. The tent shall not be used when winds are in excess of 35 mph. - pdf_text
4 4. The name and version of the compliance software tool. - pdf_text
4 4 CPVC ≤ 1-inch pipe or tubing - pdf_text
4 (cont. 2) (Amd) R311.7.1 Width. Stairways shall not be less than 36 inches (914 mm) in clear width at all p above the permitted handrail height and below the required headroom height. The clear width of stair at and below the handrail height, including treads and landings, shall not be less than 31½ inches mm) where a handrail is installed on one side and 27 inches (686 mm) where handrails are provide both sides. Exceptions: - pdf_text
4 (cont. 2) (Add) 1106.6.1.1 Van access clearance. Pursuant to subsection (i) of section 14-253a of the Connec General Statutes, each public parking garage or terminal shall have 8 feet 2 inches vertical clearance primary entrance and along the route to at least two parking spaces for passenger vans that confor - pdf_text
4 (cont. 2) (Amd) 1106.3 Groups I-1, R-1, R-2, R-3 and R-4. Accessible parking spaces shall be provided in G I-1, R-1, R-2, R-3 and R-4 occupancies in accordance with Items 1 through 4 of this section, as applic - pdf_text
40 40 Yes Vernon - pdf_text
40 40 - North Haven - pdf_text
40 40 Yes Redding - pdf_text
40 40 Yes Tolland - pdf_text
40 40 Yes Easton - pdf_text
40 40 - North Branford - pdf_text
40 40 Yes Portland - pdf_text
404.2.6 404.2.6 of ICC/ANSI A117.1. Exceptions: - pdf_text
410 410 of the Connecticut General Statutes, which have been classified as such in the State Register of His Places as long as the provisions of subsection (b) of section 29-259 of the Connecticut General Statute adhered to and provided that such exemptions shall not affect the safe design, use or construction of property. (Add) 102.9.1 Health Department regulations. Pursuant to section 19a-36 of the Connecticut Ge Statutes, no person shall construct, substantially alter or reconstruct a public pool until the constru documents and water discharge provisions have been approved by the Department of Public Healt accordance with the regulations adopted pursuant to section 19a-36 of the Connecticut General Statut Exception: Swimming pools accessory to owner-occupied, detached one-, or two- fa residences and swimming pools accessory to a single one-family townhouse where the po intended to be used exclusively by the owner and invited guests. (Del) SECTION 103 CODE COMPLIANCE AGENCY. Delete in its entirety and refer to Section of the 2021 International Building Code portion or Section R103 of the 2021 International Reside Code portion, as applicable, of the 2022 Connecticut State Building Code – Code Compliance Agenc - pdf_text
410 410 of the Connecticut General Statutes, which have been classified as such in the State Register of His Places, as long as the provisions of subsection (b) of section 29-259 of the Connecticut General Sta are adhered to and provided such exemptions shall not affect the safe design, use or construction of property. (Del) SECTION 103 – CODE COMPLIANCE AGENCY. Delete in its entirety and refer to Sectio of the 2021 International Building Code portion of the 2022 Connecticut State Building Co Enforcement Agency. (Del) SECTION 104 – DUTIES AND POWERS OF CODE OFFICIAL. Delete in its entirety and to Section 104 of the 2021 International Building Code portion of the 2022 Connecticut State Bui Code – Duties and Powers of Building Official. - pdf_text
410 (cont. 2) (Del) SECTION 104 DUTIES AND POWERS OF CODE OFFICIAL. Delete in its entirety and to Section 104 of the 2021 International Building Code portion or Section R104 of the 2021 Internat Residential Code portion, as applicable, of the 2022 Connecticut State Building Code – Duties and Po of the Building Official. (Del) SECTION 105 PERMITS. Delete in its entirety and refer to Section 105 of the 2021 Internati Building Code portion or Section R105 of the 2021 International Residential Code portion, as applic of the 2022 Connecticut State Building Code – Permits. (Del) SECTION 106 CONSTRUCTION DOCUMENTS. Delete in its entirety and refer to Section of the 2021 International Building Code portion or Section R106 of the 2021 International Reside Code portion, as applicable, of the 2022 Connecticut State Building Code – Construction Documents. (Del) SECTION 107 NOTICE OF APPROVAL Delete in its entirety and refer to Section 111.6 o - pdf_text
427.2 427.2 shall not exceed 30,000 square feet (2787 m²) with no dimension exceeding 300 feet (91 m). (Add) 429.3 Carbon monoxide detectors. Pursuant to section 29-292 of the Connecticut General Stat carbon monoxide detection shall be provided as required by Section 915. CHAPTER 5 - GENERAL BUILDING HEIGHTS AND AREAS (Add) 504.5 Group R-1 bed and breakfast establishments. The height limitation for exi unsprinklered buildings of Type VB construction undergoing a change of occupancy from detached and two-family dwellings to Group R-1 bed and breakfast establishments shall be increased by 5 feet ( mm) from the value in Table 504.3 and one story from the value in Table 504.4 where 1-hour fire-resist rated assemblies are constructed between the second and third floors. The structural members suppo the rated assemblies shall not be required to be fire-resistance rated. - pdf_text
4b 4b PP < 1-inch pipe or tubing - pdf_text
4c 4c Polyvinyl chloride (PVC) pipe - pdf_text
4c 4c Lead pipe Continuous Polyethylene/aluminum/polyethylene (PE-AL-PE) pipe - pdf_text
4c 4c CPVC pipe or tubing (1 inch in diameter and smaller) - pdf_text
4c 4c PVC pipe - pdf_text
4d 4d Polypropylene (PP) pipe or tubing, 1 inch and smaller - pdf_text
4d 4d PVC pipe - pdf_text
5 5. Water tanks supported directly upon grade if the capacity does not exceed 5,000 gallons (18 L) and the ratio of height to diameter or width does not exceed 2 to 1. - pdf_text
5 5. International Building Code. (Amd) TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - pdf_text
5 5. Fire barrier. - pdf_text
5 5. Inspect Metal-Plate Connected Wood Trusses a. Temporary installation restraint/bracing for truss spanning 60 feet or more b. Permanent individual truss member restraint/ bracing for trusses with an overall height of 60 inches or greater c. Multi-ply truss connections X - pdf_text
5 5 Copper or copper-alloy pipe - pdf_text
5 5. Accessible check-out aisles where not all aisles are accessible. The sign, where provided, sha above the check-out aisle in the same location as the check-out aisle number or type of chec identification. - pdf_text
5 5. In a building with a maximum of two dwelling units where: - pdf_text
5 5. Toilet rooms or bathing rooms that are part of critical care or intensive care patient sleeping r serving Accessible units are not required to be accessible. - pdf_text
5 5. In Group R-1 bed and breakfast establishments; in Group R-3 occupancies; within dwelling in Group R-2 occupancies; and in Group U occupancies that are accessory to Group occupancy, or accessory to individual dwelling units in Group R-2 occupancies; the maximum height shall be 8 ¼ inches (209.5 mm) and the minimum tread depth shall be 9 inches (229 the minimum winder tread depth at the walkline shall be 10 inches (254 mm); and the mini winder tread depth shall be 6 inches (152 mm). A nosing not less than ¾ inch (19.1 mm) bu more than 1 ¼ inches (32 mm) shall be provided on stairways with solid risers where the t depth is less than 11 inches (279 mm). - pdf_text
5 5. Access to the tank shall be made by careful excavation to the top of the tank. - pdf_text
5 5. An anemometer shall be installed on the tent and the tent shall be provided signage stating that the tent should be evacuated if winds exceed 35 mph. - pdf_text
5 5 p.m., except that in the case of an emergency he shall have the right of entry at any time, if such ent necessary in the interest of public safety. Pursuant to section 29-393 of the Connecticut General Stat on receipt of information from the local fire marshal or from any other authentic source that any buil in his jurisdiction, due to lack of exit facilities, fire, deterioration, catastrophe or other cause, is in condition as to be a hazard to any person or persons, the building official or his assistant shall immedi make inspection. (Amd) R104.10 Modifications. Modifications, variations, or exemptions from and approval of equiv or alternative compliance with the requirements of this code shall be in accordance with the provisio Sections 104.10.1 to 104.10.4, inclusive. (Del) R104.10.1 Flood hazard areas. Delete and substitute the following: - pdf_text
5 5. State the valuation of the proposed work. - pdf_text
5 5. Documentation of all inputs entered into the software used to produce the results fo reference design and/or the rated home. - pdf_text
5 5. Minor repair work, including the replacement of lamps and fuses or the connection of appr portable electrical equipment to approved permanently installed receptacles. Gas: - pdf_text
5 5. Replacement of any minor part that does not alter approval of equipment or make such equip unsafe. - pdf_text
5 5. If untreated, a statement that no treatment was applied when the fabric or material me requirements of Section 3102.3.1.2. (Add) 3102.3.1.4 Certificate. The certificate required by Section 3102.3.1.2 shall contain all o information specified in Section 3102.3.1.3. (Add) 3102.9 Spot lighting. Spot or effect lighting shall only be by electricity, and all combu construction located within 6 feet (1829 mm) of such equipment shall be protected with appr noncombustible insulation not less than 9¼ inches (235 mm) thick. (Add) 3102.10 Heating and cooking equipment. Heating and cooking equipment shall be in accord with Section 3104.15 of the Connecticut State Fire Safety Code. (Add) 3102.11 LP-gas. The storage, handling and use of LP-gas and LP-gas equipment shall accordance with Section 3104.16 of the Connecticut State Fire Safety Code. (Add) 3102.12 Flammable and combustible liquids. The use of flammable-fuel-fired equipment sh in accordance with Section 3104.17 of the Connecticut State Fire Safety Code. (Add) 3102.13 Separation of generators. Generators and other internal combustion power sources be separated from tents or membrane structures by a minimum of 20 feet (6096 mm) and shall be iso from contact with the public by fencing, enclosure or other approved means. - pdf_text
5 5. Within individual dwelling and sleeping units in Groups R-2 and R-3, where the buildi equipped throughout with an automatic sprinkler system installed in accordance with Se - pdf_text
5 5. Public restrooms with an area greater than 300 square feet (27.87 m2). - pdf_text
5 5. With an occupancy of 1,000 persons; - pdf_text
5 5. So that air intake opening locations are in accordance with Section R303.5.1. CHAPTER 15 – EXHAUST SYTEMS (Amd) M1502.4.2 Duct installation. Exhaust ducts shall be supported at intervals not to exceed 12 (3658 mm) and shall be secured in place. The insert end of the duct shall extend into the adjoining du fitting in the direction of airflow. Exhaust duct joints shall be sealed in accordance with Section M160 and shall be mechanically fastened. Ducts shall not be joined with screws or similar fasteners that prot more than 1/8 inch (3.2 mm) into the inside of the duct. Where dryer exhaust ducts are enclosed in w ceiling cavities, such cavities shall allow the installation of the duct without deformation. Exception: Manufactured oval duct with an equivalent diameter of 4 inches (102 mm) sha allowed. CHAPTER 19 – SPECIAL APPLIANCES, EQUIPMENT AND SYSTEMS (Amd) M1904.1 Installation. Gaseous hydrogen shall be installed in accordance with the appli requirements of Sections M1307.4 and M1903.1 and the 2021 International Building Code portion o - pdf_text
5 5. At least one accessible passenger loading zone, when loading zones are provided. - pdf_text
5 5. Heating and cooling systems, where installed at the time of the test, shall be turned off. - pdf_text
5 5. Where a platform lift is in a stationary position and the floor of the platform lift serves as the upp landing of a stairway, handrails shall not be required on the stairway, provided that all of the following criteria are met: - pdf_text
5 5. If untreated, a statement that no treatment was applied when the fabric or material me requirements of Section 3103.5.7.2. (Add) 3103.5.7.2 Certificate. The certificate required by Section 3103.5.7 shall contain all of the information specified in Section 3103.5.7.1. - pdf_text
5 5. The guard height in assembly seating areas shall comply with Section 1030.17 as applicable. - pdf_text
5 5. Exit access stairways and ramps within an atrium complying with the provisions of Section 4 - pdf_text
5 5. Slope factor(s), Cs. - pdf_text
5 5. A fabricator of wood trusses certified by the SBCRI TPI Third Party Quality Assurance Prog - pdf_text
5 5. Egress balconies as required by Section 1019.2. (Amd) 712.1.3 Escalator and stairway openings. Where a building is equipped throughout wit automatic sprinkler system in accordance with Section 903.3.1.1, vertical openings for escalato stairways which are not a portion of the means of egress shall be permitted where protected in accord with Section 712.1.3.1 or 712.1.3.2. (Amd) 712.1.3.1 Opening size. Protection by a draft curtain and closely spaced sprinklers in accord with NFPA 13 shall be permitted where the area of the vertical opening between stories does not ex twice the horizontal projected area of the escalator or stairway. In other than Groups B and M, application is limited to openings that do not connect more than four stories. CHAPTER 9 – FIRE PROTECTION SYSTEMS (Amd) 903.1.1 Alternative protection. In any occupancy where the character of fuel for fire is such extinguishment or control of fire is accomplished by a type of alternative automatic extinguishing sy complying with Section 904, such system shall be permitted in lieu of an automatic sprinkler system, shall be installed in accordance with the applicable standard and approved by the code official. (Amd) 903.2.1.2 Group A-2. An automatic sprinkler system shall be provided for fire areas contai Group A-2 occupancies and throughout all stories from the Group A-2 occupancy to and includin levels of exit discharge serving that occupancy where one of the following conditions exists: - pdf_text
5 5. Emergency exit discharge lighting. - pdf_text
5 5. In assembly seating areas, guards required at the end of aisles in accordance with Se - pdf_text
5 5. Facilities with more than eight residents shall be treated as two-family dwellings with rega water supply, and - pdf_text
5 5. In Group R-1 bed and breakfast establishments when illumination of the means of egre initiated upon initiation of a fire alarm. (Add) 1008.2.4 Arrangement of illumination. Required illumination shall be arranged so that the fa of any single lamp does not result in an illumination level of less than 0.2 foot-candle (2.15 lux) at the level. (Amd) 1008.3.3 Rooms and spaces. In the event of power supply failure, an emergency electrical sy shall automatically illuminate all of the following areas: - pdf_text
5 5. Sidewalks, driveways and on-grade concrete or masonry patios not more than 30 inches (762 above adjacent grade and not over any basement or story below. - pdf_text
5 (cont. 2) (Add) R104.10.1 Connecticut State Building Code. Pursuant to subsection (b) of section 29-254 o Connecticut General Statutes, the State Building Inspector may grant modifications, variation exemptions from, or approve equivalent or alternative compliance with, the Connecticut State Buil Code where strict compliance with the Connecticut State Building Code would entail practical diffi or unnecessary hardship, or is otherwise adjudged unwarranted, provided the intent of the law sha observed and public welfare and safety be assured. Any person aggrieved by any decision of the Building Inspector may appeal to the Codes and Standards Committee not later than 30 days after ma of the decision. (Add) R104.10.1.1 Action on application. The application for modification, variation, exemption f or approval of equivalent or alternative compliance with the requirements of the Connecticut State Buil Code shall be made on a form supplied by the State Building Inspector, which shall be submitted b applicant to the building official. Pursuant to subsection (b) of section 29-254 of the Connecticut Ge Statutes, any such application received by a building official shall be forwarded to the State Buil Inspector within 15 business days of receipt by such building official. The application shall includ building official’s comments on the merits of the application, and shall be signed by the building offic - pdf_text
5 (cont. 2) (Amd) 3103.1 General. The provisions of Sections 3103.1 through 3103.4 shall apply to structures er for a period of less than 180 days. Special event structures, tents, umbrella structures and other mem structures erected for a period of less than 180 days shall comply with Section 3103.5. Those erected longer period of time shall comply with the applicable sections of this code. (Amd) 3103.1.2 Permit required. Temporary structures that cover an area greater than 400 square fee m2), including connecting areas or spaces with a common means of egress or entrance that are us intended to be used for the gathering together of 25 or more persons, shall not be erected, operat maintained for any purpose without obtaining a permit from the building official. (Add) 3103.1.3 Outdoor assembly event. For the purposes of this section, an outdoor assembly event include a circus, carnival, tent show, theater, skating rink, dance hall or other place of assembly in or u which persons gather for any purpose. (Add) 3103.5 Tents and other membrane structures. All temporary tents and membrane structures comply with this section. (Add) 3103.5.1 Permit required. Tents and membrane structures having an area in excess of 400 s feet (37 m2) shall not be erected, operated or maintained for any purpose without obtaining a permit the building official. Exceptions: - pdf_text
5.1 5.1. Each dwelling unit has a direct independent exit to grade. - pdf_text
5.1 5.1. The stairway contains not more than two risers. - pdf_text
5.1 5.1. One means of egress and one emergency escape and rescue opening. - pdf_text
5.2 5.2. Two means of egress. - pdf_text
5.2 5.2. The exit(s) and dwelling units are separated from any nonresidential occupancy by a mini - pdf_text
5.2 5.2. A handhold, positioned horizontally or vertically, is located on one side of the stairway adja to the top landing. - pdf_text
5.3 5.3. The handhold is located not less than 34 inches (864 mm) and not more than 42 inches (1067 above the bottom landing of the stairway. - pdf_text
5.3 5.3. The nonresidential occupancy is protected by an automatic fire detection and alarm sy with notification in the dwelling unit(s). The use of any exceptions in this section shall not negate the requirements of Chapter 10. (Amd) 903.2.8.4 Care facilities. An automatic sprinkler system in accordance with Section 903.3.1.3 be permitted in a Group R-4 care facility with 16 or fewer residents when all of the following condi are met: - pdf_text
5.4 5.4. The handhold gripping surface complies with Section 1014.3, and is not less than 4.5 inches mm) in length. (Add) 1013.1.1 Accessible exits. Where exit signs are required by Section 1013.1 of this code, acces exit doors at the level of exit discharge that lead directly to accessible paths of exit discharge additionally be marked by the International Symbol of Accessibility. Such symbol shall be not less th inches (152 mm) high and shall be incorporated into the required exit sign or shall be located dir adjacent to it. Such symbol shall meet the requirements of Section 1013. (Amd) 1013.2 Low-level exit signs. Where exit signs are required from a room or space in Group occupancies, Group I-2 occupancies and Group R-2 occupancies by Section 1013.1, additional low-l exit signs shall be provided at doors within exit access corridors serving guestrooms in Group occupancies, patient and client sleeping areas of Group I-2 occupancies, and sleeping areas and dwe units in Group R-2 occupancies and shall comply with Section 1013.5. The bottom of the sign shall be not less than 10 inches (254 mm) nor more than 12 inches (305 mm) a the floor level. The sign shall be flush mounted to the door or wall on the same plane as the door. W mounted on the wall, the edge of the sign shall be within 4 inches (102 mm) of the door frame on the l side. Exception: Group R-1 bed and breakfast establishments. - pdf_text
5.4 (cont. 2) (Amd) 1014.9 Intermediate handrails. Stairways shall have intermediate handrails located in su manner that all portions of the stairway width exceeding 75 inches (1905 mm) required for egress cap are within 30 inches (762 mm) of a handrail. On monumental stairs, handrails shall be located alon most direct path of egress travel. - pdf_text
5013 5013, ASSE 5015, ASSE 5020, ASSE 5047, ASSE 5048, ASSE 5052, ASSE 5056, CSA B64.10 or B64.10.1. (Add) 312.10.2.1 Testing devices. Testing of devices shall be in accordance with section 19-13-B3 the Regulations of Connecticut State Agencies. (Add) 314.1.2 Neutralization. Liquid combustion by-products of condensing appliances shal neutralized prior to being discharged. CHAPTER 4 – FIXTURES, FAUCETS AND FIXTURE FITTINGS (Amd) 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum nu shown in Table 403.1, based on the actual use of the building or space. Uses not shown in Table 403.1 be considered individually by the building official. The number of occupants shall be determin accordance with the International Building Code. Exceptions: - pdf_text
506.3.6 506.3.6, shall be installed with the clearances specified by such listings. - pdf_text
517.16 517.16. (2) Sizing. Equipment grounding conductors and equipment bonding jumpers shall be sized in accord with 250.122. (Amd) 525.5 Overhead Conductor Clearances. Add the following exception to (B)(2): (Add) Exception: Tents erected and dismantled under the supervision of a licensed electrician or person approved by the authority having jurisdiction may be placed within the 15 feet (4.5 m) s provided the finished height of the tent is a minimum of 10 feet (3.0 m) below the conductors. CHAPTER 6 – SPECIAL EQUIPMENT (Del) 680.4 Inspections After Installation. Delete in its entirety without substitution. CHAPTER 7 - SPECIAL CONDITIONS - pdf_text
58 58, Liquefied Petroleum Gas Code, as incorporated in the 2022 Connecticut State Fire Safety Code an - pdf_text
58 58, Liquefied Petroleum Gas Code, as adopted in the 2022 Connecticut State Fire Safety Code and the Connecticut State Fire Prevention Code. These requirements apply to liquid petroleum storage systems piping systems extending from the point of delivery to the inlet connections of appliances, the install and operation of residential and commercial gas appliances and related accessories as covered by this (Add) 101.9 Connecticut State Fire Safety Code. References to the International Fire Code withi body of the model document shall be considered to be references to the 2022 Connecticut State Fire S Code. (Add) 101.10 Means of egress. In addition to the requirements of this code, means of egress in exi buildings shall meet the requirements of the 2022 Connecticut State Fire Safety Code for the prop occupancy. - pdf_text
58 58, Liquefied Petroleum Gas Code, as adopted in the 2022 Connecticut State Fire Safety and Connecticut State Fire Prevention Codes. These requirements apply to liquid petroleum storage syst gas piping systems extending from the point of delivery to the inlet connections of appliances, installation and operation of residential and commercial gas appliances and related accessories as cov by this code. (Add) 101.2.2 Electrical. The provisions of the 2020 NFPA 70, National Electrical Code, shall app the installation of electrical systems, including alterations, repairs, replacement, equipment, applia fixtures, fittings and appurtenances thereto. (Amd) 102.6 Historic buildings. Pursuant to section 29-259 of the Connecticut General Stat exemptions may be granted to the provisions of this code for historic structures, as described in sectio - pdf_text
58 58, Liquefied Petroleum Gas Code. (Add) R101.4.2 Private sewage disposal. The International Private Sewage Disposal Code is not ado by the state of Connecticut. Private sewage disposal systems shall be designed and installed in accord with the Public Health Code adopted under authority of section 19a-36 of the Connecticut General Stat Any reference to the International Private Sewage Disposal Code within the body of this code sha deemed a reference to the regulations adopted pursuant to section 19a-36 of the Connecticut Ge Statutes, known as the Public Health Code. (Add) R101.4.3 Property maintenance. The International Property Maintenance Code is not adopt the state of Connecticut. Property maintenance shall be in accordance with the requirements of this co the requirements of local property maintenance codes when such codes are adopted by the town, ci borough. References to the International Property Maintenance Code found within the body of the document shall be considered null and void. - pdf_text
58 58, Liquefied Petroleum Gas Code, as adopted in the 2022 Connecticut State Fire Safety Code and the Connecticut State Fire Prevention Code. These requirements apply to liquid petroleum storage systems piping systems extending from the point of delivery to the inlet connections of appliances, the install and operation of residential and commercial gas appliances, and related accessories as covered by this (Amd) 101.4.3 Plumbing. The provisions of the International Plumbing Code shall apply to installation, alterations, repairs and replacement of plumbing systems (including equipment, applia fixtures, fittings and appurtenances) where such systems are connected to a water or sewage system a all aspects of a medical gas system. The International Private Sewage Disposal Code is not adopted b state of Connecticut. Any reference to the International Private Sewage Disposal Code within the bo this code shall be deemed a reference to the regulations adopted pursuant to section 19a-36 of Connecticut General Statutes, known as the Public Health Code. - pdf_text
58 (cont. 2) (Amd) 101.4.4 Property maintenance. The International Property Maintenance Code is not adopte the state of Connecticut. Property maintenance shall be in accordance with the requirements of this and the applicable provisions of the 2022 Connecticut State Fire Safety Code and the 2022 Connec State Fire Prevention Code. All references to the International Property Maintenance Code found w the body of the model document shall be considered null and void. (Add) 101.4.5.1 Connecticut State Fire Safety Code. References to the International Fire Code w the body of the model documents shall be considered to be references to the 2022 Connecticut State Safety Code. (Add) 101.4.8 Electrical. The provisions of the 2020 NFPA 70, National Electrical Code, shall app the installation of electrical systems, including alterations, repairs, replacement, equipment, applia fixtures, fittings and appurtenances thereto. - pdf_text
5990 5990). (Del) 304.3.1 Circular Space. Delete section, subsections, and figures and replace with the followin (Add) 304.3.1 Circular Space. The turning space shall be a circular space with a 60-inch (1525 minimum diameter. The turning space shall be permitted to include knee and toe clearance complying - pdf_text
5a 5a Copper or copper-alloy pipe - pdf_text
5a 5a Chlorinated polyvinyl chloride (CPVC) pipe and tubing, 1 inch and smaller - pdf_text
6 6. The sprinkler system is provided with valve supervision by one of the following methods: - pdf_text
6 6. Family or assisted-use toilet and bathing rooms and single-occupancy toilet rooms. - pdf_text
6 6. Painting, papering, tiling, carpeting, cabinets, countertops and similar finish work not invol structural changes or alterations. - pdf_text
6 6. A fabricator of structural timber components and assemblies certified by the American Institu Timber Construction’s Certified Fabricator Program. At the completion of fabrication, the approved fabricator shall submit a certificate of compliance t owner or the owner’s authorized agent for submittal to the building official as specified in Section 1 stating that the work was performed in accordance with the approved construction documents. (Amd) 1705.2.4 Cold-formed steel trusses. Where a cold-formed steel truss has an overall height inches (1524 mm) or greater, the special inspector shall verify that the permanent individual truss me restraint/bracing is installed in accordance with the approved truss submittal package. Where a cold-fo steel truss clear span is 60 feet (18 288 mm) or greater, the special inspector shall verify that the temp installation restraint/bracing and the permanent individual truss member restraint/bracing are install accordance with the approved truss submittal package. - pdf_text
6 6. Means of egress components, other than those within sleeping rooms, of Group R-1 bed breakfast establishments. (Add) 1008.3.6 Activation. The emergency means of egress illumination system shall be arrang provide the required illumination automatically in the event of any interruption of normal lighting d any of the following: - pdf_text
6 6. Along alternating tread devices and ships ladders, guards whose top rail also serves as a han shall have height not less than 30 inches (762 mm) and not more than 34 inches (864 measured vertically from the leading edge of the device tread nosing. - pdf_text
6 6. The riser height and tread depth of existing stairways in buildings undergoing addition, altera repair, relocation or change of occupancy that involve the existing stairways shall be permitt remain, provided the greatest riser height within any flight of stairs shall not exceed the sma by 3/8 inch (9.5 mm) and the greatest tread depth within any flight of stairs shall not excee smallest by 3/8 inch (9.5 mm). - pdf_text
6 6. Be signed by the applicant, or the applicant’s authorized agent. - pdf_text
6 6. Sidewalks, driveways and on-grade concrete or masonry patios not more than 30 inches (762 above adjacent grade, not requiring guards, and not over any basement or story below and are not part of an accessible route. - pdf_text
6 6. Fire wall. Exceptions: - pdf_text
6 6. Within individual dwelling units and sleeping units in Group R-2 and R-3 occupancies, guar the open sides of stairs shall not have openings which allow passage of a sphere 4⅜ inches mm) in diameter. - pdf_text
6 6. At least one accessible route connecting accessible parking and accessible passenger loading z to an accessible entrance. - pdf_text
6 6 Copper or copper-alloy tubing, 11/2-inch diameter and larger - pdf_text
6 6. Toilet rooms or bathing rooms designed for bariatrics patients are not required to comply wit toilet room and bathing room requirement in ICC A117.1. The sleeping units served by bari toilet or bathing rooms shall not count toward the required number of Accessible sleeping uni - pdf_text
6 6. Supply and return registers, where installed at the time of the test, shall be fully open. Exceptions: - pdf_text
6 6. Exit access stairways and ramps in open parking garages that serve only the open parking ga - pdf_text
6 6. Group I (Institutional) use with 150 beds or persons; - pdf_text
6 6. Low voltage landscape lighting. - pdf_text
6 6. An evacuation plan certified by the operator of the tent shall be submitted t building official as part the permit application. - pdf_text
6 6. Drift surcharge load(s), pd. - pdf_text
6 6 Copper or copper-alloy tubing (11/2 inches in diameter and larger) - pdf_text
6 6. Portable evaporative coolers. - pdf_text
6 6. All exposed piping, gauging and tank fixtures, and other appurtenances, except the vent, sha disconnected and removed. - pdf_text
6 6. A certificate indicating that the proposed design has an ERI less than or equal to the approp score indicated in Section R406.5 when compared to the ERI reference design. The certif shall document the building component energy specifications that are included in calculation, including: component level insulation R-values or U-factors; assumed duct sy and building envelope air leakage testing results; and the type and rated efficienci proposed heating, cooling, mechanical ventilation, and service water-heating equipment installed. If on-site renewable energy systems will be installed, the certificate shall repor type and production size of the proposed system. - pdf_text
6 6 PB pipe or tubing - pdf_text
6 (cont. 2) (Add) 1705.2.5 Cold-formed steel light-frame construction. Special inspections of prefabricated formed steel light-frame structural elements and assemblies shall be in accordance with Section 170 Special inspections of site-built cold-formed steel light-frame structural elements and assemblies sha in accordance with this section and Table 1705.2.5. Exceptions: Special inspections, other than Items 5(a) and 5(b) of Table 1705.2.5, of site-built formed steel light-frame structural elements and assemblies shall not be required in the following c - pdf_text
6.1 6.1. A single listed control valve that shuts off both domestic and sprinkler system water su and a separate valve that shuts off the domestic system only. - pdf_text
6.2 6.2. Electrical supervision connected to the facility’s fire alarm system. - pdf_text
6.3 6.3. Valve closure that causes the sounding of an audible alarm audible throughout the premi - pdf_text
606.2.3 606.2.3, inclusive. Exception: Smoke detectors shall not be required where air distribution systems are incapabl spreading smoke beyond the enclosing walls, floors and ceilings of the room or space in whic smoke is generated, or where the sole purpose of the air distribution system is to remove air fro inside of the building to the outside of the building. CHAPTER 10 - BOILERS, WATER HEATERS AND PRESSURE VESSELS (Add) 1001.1.1 Boilers and water heaters. Boilers and water heaters shall also be governed by regulations adopted under authority of chapter 540 of the Connecticut General Statutes. - pdf_text
608.4 608.4 and 309.4. Exception: Controls in Group I-2 long-term health care facilities that provide supervised, ass bathing shall be permitted to be located outside of the shower compartment. (Amd) 703.6.3.1 International Symbol of Accessibility. Pursuant to section 29-269c of the Connec General Statutes, references in this code to the International Symbol of Accessibility shall be deem mean Connecticut’s symbol of access and shall comply with Figure 703.6.3.1. (Amd) FIG. 703.6.3.1 - pdf_text
69 69 Amendments to the 2021 International Existing Building Code - pdf_text
7 7. Width of snow drift(s), w. - pdf_text
7 7. Self-contained refrigeration systems containing - pdf_text
7 7. The tank shall be completely filled with an inert solid material. - pdf_text
7 7. Accessible dressing, fitting and locker rooms where not all such rooms are accessible. - pdf_text
7 7. Where permitted in Section 1108, in toilet rooms or bathrooms serving Accessible units, closets designed for assisted toileting shall comply with Section 1110.2.2. - pdf_text
7 7. A plan indicating the location of all ballast and weights shall be submitted t building official as part of the permit application. Ballast shall be calculate one of the following: a. For ballast systems where the tent poles and ballast are connected us common base plate or similar means, the weight of the ballast provid each tent pole shall be not less than the following: For each pole perpendicular to the ridge: Pball = 5wsx (pounds) For each pole on a hip end: Pball = 2.5wsx (pounds) - pdf_text
7 7. Group R-1 (Residential) hotels or motels with 200 rooms in a single structure; - pdf_text
7 7. At least one accessible toilet room or toilet and bathing facility complying with Section 110 of the International Building Code. Where it is technically infeasible to comply with the new construction standards for any of requirements for a change of group or occupancy, the above items shall conform to the requirements t maximum extent technically feasible. Exception: The accessible features listed in Items 1 through 7 of this Section are not required f accessible route to Type B units. - pdf_text
7 7. Self-contained refrigeration systems containing 10 pounds (4.54 kg) or less of refrigerant or are actuated by motors of 1 horsepower (746 W) or less. - pdf_text
7 7. In Group R-1 bed and breakfast establishments, guards shall have balusters or ornamental pat such that a 6-inch-diameter (152 mm) sphere cannot pass through any opening. - pdf_text
7 7. Sign illumination. - pdf_text
7 7. Exit access stairways and ramps serving smoke-protected or open-air assembly seating compl with the exit access travel distance requirements of Section 1030.7. - pdf_text
7 7. When a site-specific report is not generated, the proposed design shall be based on the w case orientation and configuration of the rated home CHAPTER 5 – EXISTING BUILDINGS (Amd) R502.3.1 Building envelope. New building envelope assemblies that are part of the addition comply with Sections R402.1, R402.2, R402.3.1 through R402.3.5 and R402.4. Exceptions: - pdf_text
7 7. In Group F occupancies where exit access stairways serve fewer than three stories and stairways are not open to the public, and where the top of the guard also serves as a handrai top of the guard shall be not less than 34 inches (864 mm) and not more than 38 inches (965 measured vertically from a line connecting the leading edges of the treads. (Amd) 1015.4 Opening limitations. Required guards shall not have openings which allow passage sphere 4 inches (102 mm) in diameter from the walking surface to the required guard height. Exceptions: - pdf_text
7 7. Painting, papering, tiling, carpeting, cabinets, countertops and similar finish work not invol new construction, structural changes or alterations. - pdf_text
7 7. Prefabricated swimming pools that are equal to or less than 24 inches (610 mm) deep. - pdf_text
7 7. See Section 503.1 of the International Existing Building Code for the replacement existing stairways. - pdf_text
7 7. Give such other data and information as required by the building official. - pdf_text
7.4-1 7.4-1 of ASCE 7 shall not be utilized, unless approved by the building official. - pdf_text
7.4-1 7.4-1 of ASCE 7 may be utilized when obstructions that would prevent sliding of snow from the roo not present. (Add) 3103.5.5.5.1 Ballast anchoring systems for tents supported only by perimeter poles. B anchoring systems for tents complying with Section 3103.5.5.4 that are supported only by perimeter and do not require X-bracing within the plane of the side walls shall be deemed to comply wit applicable wind requirements, provided the following conditions are met: - pdf_text
7.7 7.7, 7.8 and 7.9 of ASCE 7, without the 30-pounds-per-square-foot minimum requirement of pf stipula in Sections 1608.1.1 and 1608.1.2. The minimum snow load outside snow drift regions shall not be than the balanced flat roof or sloped roof snow load with the 30-pounds-per-square-foot minim requirement of pf stipulated in Sections 1608.1.1 and 1608.1.2. (Amd) 1608.2 Ground snow loads. Ground snow loads to be used in determining the design snow lo for roofs shall be as listed in Appendix P. (Add) 1608.4 Snow loads on adjacent buildings. If a new structure or addition is located within 20 (6.1 m) of an adjacent existing building, and the new structure or addition exceeds the height of adjacent existing building, a statement from a professional engineer confirming compliance with on more of the following shall be provided: - pdf_text
70 70, National Electrical Code, for any electric fire pump installed to provide an adequate water supp minimum operating pressure to a required automatic sprinkler system. (Amd) 915.1 General. Carbon monoxide detectors shall be installed in new buildings and occupanci accordance with Sections 915.1.1 through 915.6. When alterations or additions requiring a permit occ existing buildings, carbon monoxide detection shall be provided in accordance with Section 915.7. (Amd) 915.1.1 Where required. Carbon monoxide detection shall be provided in the following locat - pdf_text
700.3 700.3 Tests and Maintenance (Del) (F) Temporary Source of Power for Maintenance or Repair of the Alternate Source of Po Delete in its entirety without substitution. (Amd) 700.7 Signs. Amend (A) as follows: (Amd) (A) Emergency sources. A sign shall be placed at the service-entrance equipment, at the location, and on any equipment up to the service entrance-equipment, indicating type and location o site emergency power sources. Exception: A sign shall not be required for individual unit equipment as specified in 700.12(I). - pdf_text
703.3 703.3 of the International Building Code. Fire-resistance-rated floor-ceiling and wall assemblies extend to and be tight against the exterior wall, and wall assemblies shall extend to the underside o roof sheathing. Fire-resistance-rated assemblies shall be supported to the foundation by construction the same fire-resistance rating as the assembly supported. Exceptions: - pdf_text
710 710 and the doorway to the sleeping area hallway from such spaces shall have a minimum 20-minut resistance rating and be self-closing or automatic-closing. (Add) 407.14.1.2 Sleeping room walls. All client sleeping room walls separating the sleeping rooms the hallways and other habitable or occupiable spaces of the building shall be constructed as s partitions in accordance with Section 710. (Add) 407.14.1.3 Means of escape. In addition to the means of egress requirements of Chapter 10 following two requirements shall also be met: - pdf_text
72 72 hours. (Amd) R107.3 Temporary power. The building official is authorized to give permission to tempor supply utilities before an installation has been fully completed and the final certificate of approval has issued. The part covered by the temporary permission shall comply with the requirements specifie temporary lighting, heat or power in this code or in the NFPA 70, National Electrical Code, portion o - pdf_text
73 73 Amendments to the 2021 International Plumbing Code - pdf_text
8 8. Portable fuel-cell appliances that are not connected to a fixed piping system and are interconnected to a power grid. - pdf_text
8 8. Festoon lighting as defined in NFPA 70, National Electrical Code. - pdf_text
8 8. Group R-2 (Residential) multiple-family with 100 dwelling units in a single structure; - pdf_text
8 8. Swings, nonhabitable tree houses and other playground equipment. - pdf_text
8 8. Accessible areas of refuge required by Section 1009.9. - pdf_text
8 8. Be accompanied by a statement of special inspections as required by Section 1704.3. - pdf_text
8 8. Portable fuel cell appliances that are not connected to a fixed piping system and are interconnected to a power grid. - pdf_text
8 8 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. See Section 301.18. b. The maximum horizontal spacing of cast-iron pipe hangers shall be increased to 10 feet wher foot lengths of pipe are installed. c. Mid-story guide. d. The maximum horizontal spacing of PP or PP-RCT pipe hangers shall be increase manufacturer's installation requirements based on maximum operating temperature design. (Add) 307.1.2 Neutralization. Liquid combustion by-products of condensing appliances shal neutralized prior to being discharged. - pdf_text
8 8. Exit access stairways and ramps between the balcony, gallery or press box and the main asse floor in occupancies such as theaters, places of religious worship, auditoriums and sport facili - pdf_text
8 8. In Group I-3 facilities, stairways providing access to guard towers, observation stations and co rooms, not more than 250 square feet (23 m²) in area, shall be permitted to have a maximum height of 8 inches (203 mm) and a minimum tread depth of 9 inches (229 mm). (Amd) 1011.5.3 Winders. Winder treads are not permitted in means of egress stairways except wit dwelling unit and within existing detached one- and two-family dwellings undergoing a chang occupancy to Group R-1 bed and breakfast establishments. Exceptions: - pdf_text
8 8. The tank vent and remaining underground piping shall be capped or removed. - pdf_text
8 8. Where permitted in Section 1108, in bathrooms serving Accessible units, showers designe assisted bathing shall comply with Section 1110.2.3. - pdf_text
8 8. Existing roofs. Confirmation that existing adjacent lower roofs within 20 feet of the prop structure or addition comply with Section 1608.4. (Amd) 1603.1.6 Geotechnical information. The following geotechnical information, as applicable, be shown on the construction documents: - pdf_text
8 8 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. For sizes 2 inches and smaller, a guide shall be installed midway between required vertical sup Such guides shall prevent pipe movement in a direction perpendicular to the axis of the pipe. b. The maximum horizontal spacing of PP or PP-RCT pipe hangers shall be increase manufacturer's installation requirements based on maximum operating temperature design. CHAPTER 22 – SPECIAL PIPING AND STORAGE SYSTEMS (Amd) M2201.7 Tank abandonment and removal. Tank abandonment and removal shall b accordance with Section M2201.7.1, M2201.7.2 or M2201.7.3. (Add) M2201.7.1 Removal from service of tanks and related equipment. Except as provided in Se M2201.7.2 or M2201.7.3, if a tank and its related piping are abandoned for whatever reason, the tan all piping connected to it, including the outside fill and vent piping and any piping connected t appliance, shall be emptied of all contents, cleaned, removed from the premises or property, and disp of in accordance with applicable local, state, and federal rules and regulations. - pdf_text
8 8. Temporary motion picture, television and theater stage sets and scenery. - pdf_text
8 8 CPVC pipe or tubing, 1 inch and smaller - pdf_text
81 81 Amendments to the 2021 International Mechanical Code - pdf_text
8501 8501 East Pleasant Valley Road Cleveland, OH 44131-5516 CAN/CSA/C22.2 No. 60335-2-40—2019 Safety of Household and Similar Electrical Appliances, Part 2-40: Particular Requirements for Electri Heat Pumps, Air-Conditioners and Dehumidifiers M1403.1, M1412.1, M1413.1 (Amd) NFPA National Fire Protection Association - pdf_text
89 89 Amendments to the 2021 International Energy Conservation Code - pdf_text
9 9. Exterior areas for assisted rescue in accordance with Section 1009.9. - pdf_text
9 9. Window awnings supported by an exterior wall which do not project more than 54 inches ( mm) from the exterior wall and which do not require additional support. - pdf_text
9 9. Temporary lighting for emergencies, repairs, construction, special events or similar activities CHAPTER 28 - MECHANICAL SYSTEMS (Amd) 2801.1 Scope. The provisions of this chapter, the International Mechanical Cod the International Fuel Gas Code shall govern the design, construction, erection and installatio mechanical appliances, equipment and systems used in buildings and structures covered by this Masonry chimneys, fireplaces and barbecues shall comply with the International Mecha Code and Chapter 21 of this code. The International Existing Building Code, the International Mecha Code and the International Fuel Gas Code shall govern the alteration, repair, relocation, replacemen addition of mechanical components, appliances, equipment and systems. (Add) 2801.2 Space heaters. Space heaters shall comply with the requirements of sections 29-318 - pdf_text
9 9. Group S (Storage) parking structures with 1,000 cars. Threshold limits shall not apply to alterations, repairs or change of occupancy to any existing buildin - pdf_text
9 9. The tank excavation shall be backfilled. CHAPTER 24 – FUEL GAS (Amd) G2402.3 Terms defined in other codes. Where terms are not defined in this code and are de in other portions of the 2022 Connecticut State Building Code, such terms shall have the meanings asc to them as in those portions of the code. (Amd) G2412.2 Liquefied petroleum gas storage. The storage system for liquefied petroleum gas be designed and installed in accordance with NFPA 58. (Add) G2412.2.1 Identification label. LP-gas fuel suppliers shall affix and maintain in a legible condi their firm name(s) and emergency telephone number(s) in a readily visible location on LP-gas sup owned Department of Transportation (DOT) and American Society of Mechanical Engineers (AS containers installed on a consumer’s premises. The firm name(s) and emergency telephone number(s) be at least ½ inch (12.7 mm) high and of contrasting color to the container. The emergency telep number(s) shall be staffed 24 hours a day to ensure that the LP-gas supplier is available in the event emergency at the consumer’s premises. Cylinders, tanks or containers shall be filled, evacuate transported only by the owner of the cylinder, tank or container or upon the owner’s authorization. CHAPTER 26 – GENERAL PLUMBING REQUIREMENTS (Del) P2603.5.1 Sewer depth. Delete without substitution. - pdf_text
9 9. Stairways serving outdoor facilities where all portions of the means of egress are essentially to the outside. - pdf_text
9 9. Where toilet facilities are primarily for children’s use, required accessible water closets, t compartments and lavatories shall be permitted to comply with the children’s provisions of A117.1. (Amd) 1110.2.1.2 Family or assisted-use toilet rooms. Family or assisted-use toilet rooms shall incl only one water closet and only one lavatory and baby changing facilities. A family or assisted-use bat room in accordance with Section 1109.2.1.3 shall be considered to be a family or assisted-use toilet r Exception: The following additional fixtures shall be permitted in a family or assisted-use toilet room: - pdf_text
9 9. Identify if the structure or addition exceeds the threshold limits cited in Section 107.7. - pdf_text
9 9 for visible alarms of the International Building Code apply only to the quantity of the spaces being a Where Group I-1, I-2, R-1, R-2, R-3, or R-4 dwelling or sleeping units are being altered and where the area is greater than 50 percent of the aggregate area of the building, the requirements of Section 110 Type B units and Chapter 9 for visible alarms of the International Building Code apply only to the qua of the spaces being altered. (Amd) 306.7.16.4 Toilet facilities. Where toilet rooms are provided, not fewer than one accessible si user toilet room or one accessible family or assisted-use toilet room complying with Section 1110.2 the International Building Code shall be provided. At the inaccessible toilet rooms, directional indicating the location of the nearest accessible toilet room shall be provided. These directional signs include the International Symbol of Accessibility and sign characters shall meet the visual char requirements in accordance with ICC A117.1. (Amd) 306.7.16.5 Bathing facilities. Where bathing rooms are provided, not fewer than one acces single-user bathing room or one accessible family or assisted-use bathing room complying with Se - pdf_text
9 9. Prefabricated swimming pools accessory to a Use Group R-3 occupancy, as applicable in Se - pdf_text
903.2.11.1 903.2.11.1 through 903.2.11.7. (Add) 903.2.11.7 Additional statutory requirements. Pursuant to section 29-315 of the Connec General Statutes, automatic fire extinguishing systems shall be installed in any building or structure t built more than four stories tall and used for human occupancy and in other occupancies as required b State Fire Marshal in the interest of safety because of special occupancy hazards. (Amd) 903.3.1.1.1 Exempt locations. Automatic sprinklers shall not be required in the following ro or areas where such rooms or areas are protected with an approved automatic fire detection syste accordance with Section 907.2 that will respond to visible or invisible particles of combustion. Sprin shall not be omitted from any room merely because it is damp, is of fire-resistance-rated constructi contains electrical equipment. - pdf_text
903.3.1 903.3.1 with other than Group H or I occupancies, exit access stairways and ramps servin occupant load of less than 10 not more than one story above the level of exit discharge. - pdf_text
903.3.1.1 903.3.1.1, 903.3.1.2 or 903.3.1.3, sleeping rooms in basements shall not be required to emergency escape and rescue openings provided that the basement has one of the followi - pdf_text
915.1.6 915.1.6 exist. (Amd) 915.1.2 Fuel-burning appliances and fuel-burning fireplaces. Carbon monoxide detection be provided in dwelling units and sleeping units that contain a fuel-burning appliance or fuel-bu fireplace. (Amd) 915.1.3 Fuel-burning, forced-air furnaces. Carbon monoxide detection shall be provid dwelling units and sleeping units served by a fuel-burning, forced-air furnace. Exception: Carbon monoxide detection shall not be required in dwelling units and sleeping unit carbon monoxide detector is provided in the first room or area served by each main duct leavin furnace, and the carbon monoxide alarm signals are automatically transmitted to an approved loca (Amd) 915.1.4 Fuel-burning appliances outside of dwelling units and sleeping units. Carbon mon detection shall be provided in dwelling units and sleeping units located in buildings that contain burning appliances or fuel-burning fireplaces. - pdf_text
915.4.1 915.4.1. For the purpose of this section, “work area” is defined as: that portion or portions of a buil consisting of all reconfigured spaces as indicated on the construction documents. Work area excludes portions of the building where incidental work entailed by the intended work must be performed portions of the building where work not initially intended by the owner is specifically required by this Exceptions: - pdf_text
927 927 L) capacity and are installed entirely above ground. - pdf_text
97 97 Amendments to the 2020 NFPA 70, National Electrical Code - pdf_text
Section 1014 Section 1014. Where glass is used to provide the handrail, the handrail shall comply with Section 24 Exceptions: - pdf_text
Section 108 Section 108 of the 2021 International Building Code portion or Section R107 of the 2021 Internati Residential Code portion, as applicable, of the 2022 Connecticut State Building Code – Temp Structures and Uses. (Del) SECTION 108 FEES. Delete in its entirety and refer to Section 109 of the 2021 Internati Building Code portion or Section R108 of the 2021 International Residential Code portion, as applic of the 2022 Connecticut State Building Code – Fees. (Del) SECTION 109 INSPECTIONS. Delete in its entirety and refer to Section 110 of the International Building Code portion or Section R109 of the 2021 International Residential Code por as applicable, of the 2022 Connecticut State Building Code – Inspections. (Del) SECTION 110 CERTIFICATE OF OCCUPANCY. Delete in its entirety and refer to Sectio of the 2021 International Building Code portion or Section R110 of the 2021 International Reside Code portion, as applicable, of the 2022 Connecticut State Building Code – Certificate of Occupancy. (Del) SECTION 111 SERVICE UTILITIES. Delete in its entirety and refer to Section 112 of the International Building Code portion or Section R111 of the 2021 International Residential Code por as applicable, of the 2022 Connecticut State Building Code – Service Utilities. - pdf_text
Section 108 (cont. 2) (Del) SECTION 112 – MEANS OF APPEALS. Delete in its entirety and refer to Section 113 of the International Building Code portion or Section R112 of the 2021 International Residential Code por as applicable, of the 2022 Connecticut State Building Code – Means of Appeal. (Del) SECTION 113 - VIOLATIONS. Delete in its entirety and refer to Section 114 of the International Building Code portion or Section R113 of the 2021 International Residential Code por as applicable, of the 2022 Connecticut State Building Code – Violations. - pdf_text
Section 1106.6.1 Section 1106.6.1 and that have 8 feet 2 inches of vertical clearance. (Amd) 1108.6.2.2.1 Type A units. In Group R-2 occupancies containing more than 20 dwelling uni sleeping units, at least 10 percent of the units shall be a Type A unit in accordance with ICC/ANSI A1 All R-2 units on the site, within the building or within the complex shall be considered to determin total number of units and the required number of Type A units. Type A units shall be dispersed amon various classes of units. Exceptions: - pdf_text
Section 116 Section 116 of the 2021 International Building Code portion of the 2022 Connecticut State Building – Unsafe Buildings and Equipment. (Del) SECTION 116 – EMERGENCY MEASURES. Delete in its entirety and refer to Section 1 the 2021 International Building Code portion of the 2022 Connecticut State Building Code – Emerg Measures. (Del) SECTION 117 – DEMOLITION. Delete in its entirety and refer to Section 102.6.3 of the International Building Code portion of the 2022 Connecticut State Building Code – Demolitio Structures. CHAPTER 2 – DEFINITIONS (Amd) 201.3 Terms defined in other codes. Where terms are not defined in this code and are defin other codes adopted as portions of the 2022 Connecticut State Building Code, such terms shall hav meanings ascribed to them as in those codes. (Add) 202.1 Definitions. Amend or add the following definitions: (Add) BUILDING OFFICIAL. The officer or other designated authority charged with the administr and enforcement of this code, or a duly authorized representative. Also known as the local building off or the code official. (Amd) CODE OFFICIAL. See Building official. (Amd) EXISTING BUILDING. A building or structure, or portion thereof, erected in whole or in for which a legal building permit and a certificate of occupancy has been issued. Buildings or structur portions thereof erected prior to October 1, 1970 shall be deemed existing buildings regardless o existence of a legal permit or a certificate of occupancy. - pdf_text
Section 116 Section 116 has been instituted. (Add) 117.3 Temporary closings. When necessary for public safety, the building official shall tempor close buildings and structures and close, or order the authority having jurisdiction to close, sidew streets, public ways and places adjacent to unsafe structures, and prohibit the same from being used. (Add) 117.4 Emergency work. When imminent danger or an unsafe condition requiring immediate a exists and the owner of the building or structure cannot be located, or refuses or is unable to expeditio render the premises safe, the building official shall order the employment of the necessary labor materials to perform the required work as expeditiously as possible. Such work shall include that requ in the building official’s sole opinion, to make the premises temporarily safe, up to and inclu demolition. (Add) 117.5 Costs of emergency work. Costs incurred in the performance of emergency repair demolition under the order of the building official shall be paid from the treasury of the town, cit borough in which the building or structure is located on approval of the building official. The legal co of the town, city or borough shall institute appropriate action against the owner of the premises wher unsafe building or structure is or was located. (Add) SECTION 118 – VACANT BUILDINGS - pdf_text
Section 116 Section 116 of this code. Work performed under such permits shall be completed as expeditious possible. (Add) 105.5.1 Nine-year closure. Pursuant to subsection (c) of section 29-265 of the Connecticut Ge Statutes, nine years from the date of issuance of a building permit issued pursuant to section 29-263 o Connecticut General Statutes for construction or alteration of a one-family dwelling, two-family dwe or structure located on the same parcel as a one-family dwelling or two-family dwelling, for w construction or alteration a certificate of occupancy, as defined in the regulations adopted pursua - pdf_text
Section 116 (cont. 2) (Add) 118.1 General. Temporarily unoccupied buildings, structures, premises or portions thereof, including tenant spaces, shall be safeguarded and maintained in accordance with this section. (Add) 118.1.1 Abandoned premises. Buildings, structures and premises for which an owner cann identified or located by dispatch of a certificate of mailing to the last known or registered address, w persistently or repeatedly become unprotected or unsecured; which have been occupied by unauthor persons or for illegal purposes; or which present a danger of structural collapse or fire spread to adja properties shall be considered abandoned, declared unsafe and abated or demolished in accordance this code. - pdf_text
Section 116 (cont. 2) (Amd) TECHNICALLY INFEASIBLE. An alteration of a building or a facility that has little likeli of being accomplished because the existing structural conditions require the removal or alteration of a l bearing member that is an essential part of the structural frame, or because other physical or site constr prohibit modification or addition of elements, spaces or features that are in full and strict compliance the minimum requirements for new construction and that are necessary to provide accessibility. Pur to subsection (b) of section 29-269 of the Connecticut General Statutes, the determination of tech infeasibility shall be made by the State Building Inspector. CHAPTER 3 – PROVISIONS FOR ALL COMPLIANCE METHODS (Amd) 302.2 Additional codes. Alterations, repairs, additions and changes of occupancy to, or reloc of, existing buildings and structures shall comply with the provisions for alterations, repairs, addition changes of occupancy or relocation, respectively, in this code and the International Energy Conserv Code, International Mechanical Code, International Plumbing Code, International Residential Cod NFPA 70. Where provisions of the other codes conflict with provisions of this code, the provisions o code shall take precedence. - pdf_text
Section 306 Section 306. (Add) FIGURE 304.3.1 Circular Turning Space. (Del) 304.3.2 T-Shaped space. Delete section, subsections, and figures and replace with the followi (Add) 304.3.2 T-Shaped space. The turning space shall be a T-shaped space within a 60-inch (1525 minimum square, with arms and base 36 inches (915 mm) minimum in width. Each arm of the T sha clear of obstructions 12 inches (305 mm) minimum in each direction, and the base shall be cle obstructions 24 inches (610 mm) minimum. The turning space shall be permitted to include knee an clearance complying with Section 306 only at the end of either the base or one arm. - pdf_text
Section 7.3 Section 7.3 of ASCE 7. The calculated value of pf shall not be less than 30 pounds per square foot and be used in the calculation of sloped roof snow loads in accordance with Section 7.4 of ASCE 7. provisions of Section 7.3.4 of ASCE 7 shall not be used. (Add) 1608.1.2 Sloped roof snow loads. The sloped roof snow load, ps, shall be calculated in accord with Section 7.4 of ASCE 7. The value of pf used in such calculation shall not be less than 30 pound square foot, except where permitted in Section 1608.1.3. Values for “unobstructed slippery roofs” in F - pdf_text
Section 903.3.1.1 Section 903.3.1.1 or Section 903.3.1.2 and where the highest floor level is not more than 75 feet a the lowest level of fire department vehicle access, Class I standpipes shall have an automatic or ma wet supply. (Del) 905.3.4.1 Hose and cabinet. Delete section. (Del) SECTION 906 - PORTABLE FIRE EXTINGUISHERS. Delete this section in its entirety replace with the following: (Add) SECTION 906 - PORTABLE FIRE EXTINGUISHERS (Add) 906.1 Where required. Portable fire extinguishers shall be provided in occupancies and loca as required by the 2022 Connecticut State Fire Prevention Code. (Add) 906.2 Maintenance. Portable fire extinguishers shall be maintained in accordance with the Connecticut State Fire Prevention Code. - pdf_text
Section 907 Section 907 of the International Building Code as required for new construction. CHAPTER 12 – HISTORIC BUILDINGS (Add) 1201.1.1 Exemptions. Pursuant to section 29-259 of the Connecticut General Statutes, exempt may be granted to the provisions of this code for historic structures. CHAPTER 13 – PERFORMANCE COMPLIANCE METHODS (Amd) 1301.2 Applicability. Existing buildings or structures in which there is work involving addit alterations or changes of occupancy shall be made to conform to the requirements of this chapter o provisions of Chapters 6 through 12. The provisions of Sections 1301.2.1 through 1301.2.6 shall app existing occupancies that will continue to be, or are proposed to be, in Groups A, B, E, F, I-2, M, R a These provisions shall also apply to Group U occupancies where such occupancies are undergoing a ch of occupancy or a partial change in occupancy with separations in accordance with Section 1301.2.2. T provisions shall not apply to buildings with occupancies in Group H, I-1, I-3 or I-4. CHAPTER 16 – REFERENCED STANDARDS (Amd) NFPA National Fire Protection Association - pdf_text
Section 907.2.11.2 Section 907.2.11.2. (Add) 907.2.11.2.2 Alterations and additions. When an alteration or addition is made to a buildin structure of Group I-4 and E day care facilities, Group I-1 or R occupancy, or when one or more slee rooms are added or created in existing dwelling units, the entire dwelling unit or building shall be prov with smoke detectors located as required for new buildings. Such smoke detectors within existing sp - pdf_text
section 10-410 section 10-410 of the Connecticut General Statutes, which have been classified as such in the State Reg of Historic Places as long as the provisions of subsection (b) of section 29-259 of the Connecticut Ge Statutes are adhered to and provided that such exemptions shall not affect the safe design, us construction of such property. (Add) 104.10.4 Urban homesteading property exemption. Pursuant to section 29-259 of the Connec General Statutes, exemptions may be granted to the provisions of this code for property acquired b urban homesteading agency, pursuant to section 8-169r of the Connecticut General Statutes and transf to a qualified applicant pursuant to section 8-169s of the Connecticut General Statutes, provided exemptions shall not affect the safe design, use or construction of such property. Exemptions sha granted in accordance with Section 104.10.1 of this code. (Add) 104.10.5 Elevators and escalators. Pursuant to section 29-192 of the Connecticut General Stat the State Building Inspector may approve variations or exemptions from, or equivalent or alte compliance with, regulations governing elevators and escalators where strict compliance with provisions would cause practical difficulty or unnecessary hardship. Any person aggrieved by the dec of the State Building Inspector may appeal to the Commissioner of Administrative Services or commissioner’s designee not later than 30 days after notice of such decision has been rendered. - pdf_text
section 10-410 section 10-410 of the Connecticut General Statutes, which have been classified as such in the State Re of Historic Places as long as the provisions of subsection (b) of section 29-259 of the Connecticut Ge Statutes are adhered to and provided that such exemptions shall not affect the safe design, u construction of such property. Exemptions shall be granted in accordance with Section R104.10.1 o code. (Add) R104.10.4 Urban homesteading property exemption. Pursuant to section 29-259 of Connecticut General Statutes, exemptions may be granted to the provisions of this code for pro acquired by an urban homesteading agency, pursuant to section 8-169r of the Connecticut General Stat and transferred to a qualified applicant pursuant to section 8-169s of the Connecticut General Stat provided such exemptions shall not affect the safe design, use or construction of such property. Exemp shall be granted in accordance with Section R104.10.1 of this code. (Add) R104.11.2 Research reports. Submission to the local building official of a valid research r prepared by an approved evaluation service that supports the efficacy of use of any material, applia equipment or method of construction not specifically provided for in this code, or that demonst compliance with this code, may be deemed evidence of compliance with this code. - pdf_text
section 10-410 (cont. 2) (Amd) R105.1 Required. Any owner or owner’s authorized agent who intends to construct, enlarge, repair, move, demolish or change the occupancy of a building or structure, or to move a lot line that affect any existing building or structure, or to erect, install, enlarge, alter, repair, remove, convert or re any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this cod to cause any such work to be performed, shall first make application to the building official and obtai required permit. (Add) R105.1.1 By whom application is made. Pursuant to section 29-263 of the Connecticut Ge Statutes, application for a permit shall be made by the owner or by an authorized agent. If the autho agent is a contractor, such contractor shall follow the provisions of section 20-338b of the Connec General Statutes. The applicant shall include the full names and addresses of the owner, agent an responsible officers, if the owner or agent is a corporate body. (Add) R105.1.2 Permit issuance to a home improvement contractor. No permit shall be issued contractor who is required to be registered pursuant to chapter 400 of the Connecticut General Statute work to be performed by such contractor, unless the name, business address and Department of Cons Protection registration number of such contractor is clearly marked on the application for permit, an contractor has presented such contractor’s certificate of registration as a home improvement contracto - pdf_text
section 10-410 (cont. 2) (Add) 104.10.6 Lift and limited use/limited application elevator approval. Lifts and limited use, li access elevators shall not be part of a required accessible path unless approved in accordance wit provisions of Section 1110.9 of this code. (Amd) 105.1 Required. Any owner or owner’s authorized agent who intends to construct, enlarge, repair, move, demolish or change the occupancy of a building or structure, or to move a lot line that affect any existing building or structure, or to erect, install, enlarge, alter, repair, remove, convert or re any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this cod to cause any such work to be performed, shall first make application to the building official and obtai required permit. (Add) 105.1.3 Connecticut State Fire Safety Code abatement. Where conflicts exist betwee requirements of this code and the requirements of a Connecticut State Fire Safety Code abatement issued in writing by the local fire marshal with respect to an existing building, the requirements of portion of the Connecticut State Fire Safety Code that regulates existing buildings shall take preceden Exceptions: - pdf_text
section 19a-36 section 19a-36 of the Connecticut General Statutes. Exception: Swimming pools accessory to owner-occupied, detached one-, two- or three-fa residences and swimming pools accessory to a single one-family townhouse where the pool is inte to be used exclusively by the owner and invited guests. (Add) 3109.2 Public swimming pools. Public swimming pools shall be completely enclosed by a ba meeting the requirements of 2021 International Swimming Pool and Spa Code portion of the Connecticut State Building Code. (Add) 3109.3 Swimming pool barriers. Residential and public swimming pool barriers shall comply the requirements of 2021 International Swimming Pool and Spa Code portion of the 2022 Connec State Building Code. (Del) SECTION 3114 PUBLIC USE RESTROOM BUILDINGS IN FLOOD HAZARD AR Delete section in its entirety CHAPTER 33 – SAFEGUARDS DURING CONSTRUCTION (Add) 3303.8 Demolition of structures. The demolition of structures shall be conducted in accord with the State Demolition Code as found in part IV of chapter 541 of the Connecticut General Statutes with this chapter. - pdf_text
section 19a-77 section 19a-77 of the Connecticut General Statutes, that operates in accordance with the licen requirements of the Office of Early Childhood shall be classified as Group R-3 or shall comply wit International Residential Code. (Add) 307.5.1 Consumer fireworks, Class 1.4G. Sparklers and fountain display items permitted to be in Connecticut shall be exempt from the requirements of an H-3 occupancy under the follo circumstances: - pdf_text
section 29-252 section 29-252 of the Connecticut General Statutes, has not been issued by the building official, building permit shall be deemed closed. (Amd) 107.2.1 Information on construction documents. Construction documents shall be dimensi and drawn on suitable material. Electronic media documents are permitted to be submitted where appr by the building official. Construction documents shall be of sufficient clarity to indicate the location, n and extent of the work proposed and show in detail that it will conform to the provisions of this code relevant laws, ordinances, rules and regulations, as determined by the building official. When the qu or arrangement of materials is essential for conformity to this code, specific information shall be giv establish such quality or arrangement, and this code shall not be cited, or terms such as “legal,” “per c or their equivalent used as a substitute for specific information. - pdf_text
section 29-252 (cont. 2) (Amd) 107.2.2 Fire sprinkler system shop drawings. Shop drawings for fire sprinkler system(s) sha submitted to indicate conformance to this code and the construction documents and shall be approved to the start of system installation. Shop drawings shall contain all information as required by the refere installation standards in Chapter 9. Pursuant to section 29-263a of the Connecticut General Statutes, documents shall be accompanied by evidence of licensure as an automatic fire sprinkler layout techni in accordance with section 20-304a of the Connecticut General Statutes or a professional engineer lice in accordance with chapter 391 of the Connecticut General Statutes. (Add) 107.2.6.2 Private sewage disposal system. The site plan shall indicate the location of a pri sewage disposal system where a public sewer is not available. Private sewage disposal systems sha designed and installed in accordance with the requirements of the Public Health Code adopted u authority of section 19a-36 of the Connecticut General Statutes. All technical and soil data required b Public Health Code shall be submitted with the site plan. Approval of such systems shall be by the l authority having jurisdiction. When such approval is required by the local authority having jurisdic written proof of such approval shall be submitted to the building official prior to issuance of a buil permit. - pdf_text
section 29-252 (cont. 3) (Amd) 107.3.4.1 Deferred submittals. Deferral of any submittal items shall have the prior approval o building official. The registered design professional in responsible charge shall list the deferred submi on the construction documents for review by the building official. Documents for deferred submittal items shall be submitted to the registered design profession responsible charge, who shall review them and forward them to the building official with a not indicating that the deferred submittal documents have been reviewed and found to be in ge conformance to the design of the building. The deferred submittal items shall not be installed unti deferred submittal documents have been approved by the building official. - pdf_text