Chicago, IL — Building Code (Title 14B)

(jurisdiction reference document) / - / - / pdf_2d

3767 clause(s)

LabelTextPageExtraction method
0 0 to less than 3 b, c, k Unprotected, Nonsprinklered (UP, NS) Not Permitt Unprotected, Sprinklered (UP, S) i Not Permitt Protected (P) Not Permitt 55 pdf_text
0 0 to less than 3 53 pdf_text
0.25 0.25 f 'c Precast nonprestressed 171 pdf_text
0.3 0.3 f 'c Cast-in-place grout without a permanent casing 171 pdf_text
0.33 0.33 f 'c Precast prestressed 171 pdf_text
0.33 0.33 f 'c Cast-in-place concrete without a permanent casing 171 pdf_text
0.35 0.35 Fy ≤ 24,000 psi 171 pdf_text
0.4 0.4 f 'c Cast-in-place in a pipe, tube, other permanent casing 171 pdf_text
0.4 0.4 fy ≤ 30,000 psi 171 pdf_text
0.4 0.4 Fy ≤ 32,000 psi Other pipes, tubes, helicals or H-piles 171 pdf_text
0.5 0.5 Fy ≤ 32,000 psi Other pipes, tubes, helicals or H-piles 171 pdf_text
0.5 0.5 Fy ≤ 32,000 psi Pipes, tubes, helicals or H-piles, where justified in accordance with Section 171 pdf_text
0.5 0.5 Fy ≤ 32,000 psi Pipes or tubes for micropiles 171 pdf_text
0.5 0.5 fy ≤ 40,000 psi 171 pdf_text
0.6 0.6 fy ≤ 40,000 psi Other conditions 171 pdf_text
1 1. Revise Section 1505.2 by replacing "approved testing agency" with "approved agency." 136 pdf_text
1 1. Delete the last two sentences of Section 3307.1. 209 pdf_text
1 1. Noncombustible materials. 212 pdf_text
1 1. Revise Section 1707.1 to read: "1707.1 General. New materials shall be evaluated in accordance with Chapter 10 of the Chicago Construction Codes Administrative 161 pdf_text
1 1. Revise Table 1607.1 by replacing “OCCUPANCY OR USE” with “FUNCTION OR USE” in the heading of the 146 pdf_text
1 1. The bottom of the clear opening of an operable window is located less than 24 inches (610 the finished floor and at least 72 inches (1829 mm) but not more than 20 feet (6096 mm) abov grade or other surface below on the exterior of the building. 100 pdf_text
1 1. Revise exception 1 to Section 1011.2 by replacing "an occupant load" with "a story or mezzanine with an occupa 95 pdf_text
1 1. Stairways connecting five or more stories shall be built of and supported by noncombustib Shaft enclosures for stairways connecting five or more stories shall be built of noncombustibl 97 pdf_text
1 1. Revise the first sentence of Section 2513.3 to read: "The bedding coat for interior surfaces or exterior surfaces shall be composed of one part Portland cement and one p lime; or one part blended cement and one part Type S lime; or masonry cement; or plastic cement and not more than graded white or natural sand by volume." 191 pdf_text
1 1. Revise Section 902.1.2 by deleting "with an approved sign." 67 pdf_text
1 1. Flights of stairs within dwelling units and spiral stairways are permitted to have a handrail on one 97 pdf_text
1 1. Revise item 1 in the first paragraph of Section 1605.1 to read: "1. The load combinations specified in Section 1605.2 or 1605.3.1." 146 pdf_text
1 1. Revise note c to Table 2304.8(3) to delete "approved." 184 pdf_text
1 1. Revise Section 1407.4.1 and its subsections to read: "1407.4.1 Drainage. EIFS without drainage (barrier-type) shall not be permitted. EIFS shall have an average minimum drainage efficienc when tested in accordance with the requirements of ASTM E2273. Details of the required drainage mechanisms shal on the construction documents. 132 pdf_text
1 1. Revise the exception to Section 1908.4.2 to read: "Exception: Where approved by the building official, required clearances may be reduced where it is demonstrated preconstruction tests that adequate encasement of the bars used in the design will be achieved." 177 pdf_text
1 1. Revise Section 2502.1 by adding the following at the end: "Where walls or ceiling coverings of gypsum materials will be permanently or periodically exposed to the exterior c must be designed for exterior exposure." 190 pdf_text
1 1 UL B NS UL 38 pdf_text
1 1. Rooms and spaces accessory to an assembly occupancy providing such day care during events sha as part of the primary occupancy. 20 pdf_text
1 1. Add a new exception to Section 914.1.1 to read: "Exception: Markings shall not be required on shaftway openings that are readily discernible as openings onto a sha construction or arrangement." 81 pdf_text
1 1. In provisions adopted by reference, reset the following terms in italic type: "accessible"; "approved"; "building of "carport"; "open parking garage"; "private garage" and "repair garage." 28 pdf_text
1 1. Revise the last sentence of Section 2104.1.2 to read: "Terra cotta and metal cornices shall be anchored to a structural frame of noncombustible material." 179 pdf_text
1 1. In kitchens, at least 5 percent, but no less than one of each type of storage facility p comply with Section 905. Types of storage facilities include: drawers, open shelves, an cabinets. 109 pdf_text
1 1. Revise Section 911.1.1 to read: "911.1.1 Location and access. The location and accessibility of the fire command center shall be reviewed and accepted by the fire code official. Th command center shall comply with the following criteria: 79 pdf_text
1 1. Fire walls are not required on property lines dividing a building on a single zoning lot for owners where the aggregate height and area of the portions of the building located on both sides of the proper exceed the maximum height and area requirements of this code and a perpetual recorded easement or contractual agreement, such as a condominium declaration, authorizes the owners of portions of the b on either side of the property line to access the other side for purposes of maintaining the building an 57 pdf_text
1 1. Revise Section 501.1 by adding a second paragraph to read: "Nothing in this chapter shall be interpreted to prevent the application of other limitations provided by the Chicago Z Ordinance." 35 pdf_text
1 1. In buildings and structures assigned to Seismic Design Category C, special are not required for structural steel seismic force-resisting systems where the re modification coefficient, R, designated for "Steel systems not specifically detail resistance, excluding cantilever column systems" in ASCE 7, Table 12.2-1, has design and detailing. 158 pdf_text
1 1. Delete the exceptions to Section 3104.3. 203 pdf_text
1 1. The reactions resulting from the dead load and live load specified in Table 1607.1, or the snow loa 145 pdf_text
1 1. Revise Section 2508.4 to read: "2508.4 Adhesives. Gypsum board and gypsum panel products secured to framing with adhesives in ceiling assemblies shall be attached fastening schedule recommended by the manufacturer. Expandable foam adhesives for fastening gypsum wallboard to ASTM D6464. Other adhesives for the installation of gypsum wallboard shall conform to ASTM C557." 190 pdf_text
1 1. Aggregate used as surfacing for roof coverings. 135 pdf_text
1 1. Revise section 3003.2 to read: "3003.2 Fire fighters’ emergency operation. Elevators shall be provided with Phase I emergency recall operation and Phase II emergency in-car operation in acco Chapters 3 and 4 of the Chicago Conveyance Device Code." 199 pdf_text
1 1. Revise Section 3305.1 to read: "3305.1 Facilities required. Adequate sanitary facilities for workers shall be provided during construction, rehabilitation or demolition activities with the Chicago Plumbing Code." 209 pdf_text
1 1. The minimum diameter for drilled micropiles shall be 4.5 inches (114 mm) and for jacked inches (76 mm). 173 pdf_text
1 1. Revise Section 2205.2.1.2 to read: "2205.2.1.2 Seismic Design Category D. Structures assigned to Seismic Design Category D shall be designed and detailed in accordance with AISC 341, exce in ASCE 7, Table 15.4-1." 181 pdf_text
1 1. Foam plastic insulation shall conform to the material and installation requirements of Cha 138 pdf_text
1 1. Delete exception 1 to Section 1020.1. 101 pdf_text
1 1. Revise Tables 1507.1.1(1), 1507.1.1(2) and 1507.1.1(3) by changing the title of the third column to "INSTALLA STANDARD" and deleting the fourth column. 136 pdf_text
1 1. In occupancy Group R-2, R-3 or R-5, threshold heights for sliding and side-hinged exterior doors permitted to be up to 8 inches (203 mm) in height if all of the following apply: 93 pdf_text
1 1. Elevators cars. 76 pdf_text
1 1. The sheathing is gypsum board or fiberboard. 159 pdf_text
1 1. Revise Section 2601.1 by replacing "foam plastic insulation" with "foam plastic insulation (including insulated p foam plastic insulation)." 192 pdf_text
1 1 I-4 NS UL 38 pdf_text
1 1. Revise Section 2112.4 by replacing "Seismic Design Category D, E or F" with "Seismic Design Category D." 179 pdf_text
1 1. Revise Table 2506.2 by inserting a row to read: "Abuse-resistant gypsum panel products | ASTM C1629" 190 pdf_text
1 1. Revise the last sentence of Section 1004.5 to read: "Where an intended function is not listed in Table 1004.5, selection of a listed function that most nearly resembles th function shall be approved by the building official." 85 pdf_text
1 1. A shaft enclosure in accordance with Section 713. 62 pdf_text
1 1. Smoke control system. 27 pdf_text
1 1. Add a new Section 901.1.1 to read: "901.1.1 Modification of reference standards. The fire code official shall be authorized to promulgate rules, not inconsistent with this code, which modify the follo referenced standards for the design of fire protection systems for consistency with existing installations and the opera Chicago Fire Department: NFPA 10, NFPA 13, NFPA 13D, NFPA 13R, NFPA 14, NFPA 20, NFPA 25, NFPA 72 a Where the fire code official has promulgated such rules and posted them on the city's public web site, references to s in the Chicago Construction Codes shall mean such standards as modified by the fire code official's rules. 66 pdf_text
1 1. Revise Section 712.1.2 to read: "712.1.2 Individual dwelling unit. Unconcealed and unprotected vertical openings totally within an individual residential dwelling unit and connecting less shall be permitted." 59 pdf_text
1 1. Delete Section 802.4. 64 pdf_text
1 1. Revise exception 1 to Section 913.2.1 to read: "1. In buildings less than 55 feet (16.8 m) in building height, separation by 1-hour fire barriers constructed i with Section 707 or 1-hour horizontal assemblies constructed in accordance with Section 711, or both, shall b buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 9 81 pdf_text
1 1. Revise Section 2604.1 by deleting "where approved." 194 pdf_text
1 1. Group H occupancies shall be separated from all other occupancies in accordance with Section 50 45 pdf_text
1 1. Revise exception 1 to Section 1028.1 by replacing "through areas on the level of discharge" with "through a lobb common area on the level of exit discharge." 104 pdf_text
1 1. Bathrooms, toilet rooms, kitchens, storage rooms, laundry rooms and spaces above and bel mezzanine shall have a ceiling height of not less than 7 feet (2134 mm) above the finished floo 125 pdf_text
1 1. Any building, structure or site improvement which is: owned by or on behalf of a governmental u rented or used in whole or in part, by a governmental unit; or financed, in whole or in part, by a grant or guaranteed by a governmental unit. 13 pdf_text
1 1. Revise Section 714.4.1.1 by deleting "approved." 60 pdf_text
1 1 I-2, Condition 2 NS f UL 38 pdf_text
1 1. The structure consists of light-frame construction; and the building height of the structure exceed 35 feet (10 668 mm). 158 pdf_text
1 1. Revise Section 2407.1 to read: "2407.1 Materials. Glass used in a guard or to support a handrail shall be laminated glass constructed of fully tempered or heat- strengt shall comply with Category II or CPSC 16 CFR Part 1201 or Class A of ANSI Z97.1. Glazing in guard in-fill panels recognized safety glazing material that conforms to the provisions of Section 2406.1.1. For all glazing types, the min thickness shall be 1/4 inch (6.4 mm). Exception: Single fully tempered glass complying with Category II of CPSC 16 CFR Part 1201 or Class A o shall be permitted to be used in guards where there is no walking surface beneath them or the walking surfac permanently protected from the risk of falling glass." 188 pdf_text
1 1. Does not connect more than two stories and: 59 pdf_text
1 1 hour Waste, recycling and linen collection rooms over 100 square feet 46 pdf_text
1 1. Temporary tents, canopies, platforms, stages reviewing stands and similar structures. 219 pdf_text
1 1. Revise Section 701.1 to read: "701.1 Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance a resistance-rated construction, separation of adjacent spaces to safeguard against the spread of fire and smoke within the spread of fire to or from buildings." 51 pdf_text
1 1. Revise Section 1807.1.3 by replacing "Seismic Design Category C, D, E or F" with "Seismic Design Category C 168 pdf_text
1 1. The name and address for the owner of the structure. 202 pdf_text
1 1. Revise items 2, 3 and 4 in Section 1019.3 to read: "2. In Group R-1, R-2, R-3 or R-5 occupancies, exit access stairways and ramps connecting four stories or l contained within an individual dwelling unit or sleeping unit or live/work unit. 101 pdf_text
1 1. Revise exception 1 to Section 405.1 by replacing "One- and two-family dwellings" with "Group R-5 occupancies 27 pdf_text
1 1. The types of domestic cooking appliances permitted shall be limited to ovens, cooktops, ra makers, warmers and microwaves. 34 pdf_text
1 1. Revise Section 2306.1.3 by replacing "an approved method" with "a method." 185 pdf_text
1 1. Occupancies in Group U. 92 pdf_text
1 1. In provisions adopted by reference, reset the following term in italic type: "MCM system." 132 pdf_text
1 1. Revise Section 1907.1 by deleting "approved" and replacing "6 inches (152 mm)" with "12 inches (305 mm)." 177 pdf_text
1 1. Revise Section 1003.3.1 to read: "1003.3.1 Headroom. Protruding objects are permitted to extend below the minimum ceiling height required by Section 1003.2 where a mi headroom of 80 inches (2032 mm) is provided over any circulation paths, including walks, corridors, aisles and pass more than 50 percent of the ceiling area of a means of egress shall be reduced in height by protruding objects. A barrier shall be provided where the vertical clearance above a circulation path is less than 80 inches (2032 mm) hi finished floor. The leading edge of such a barrier shall be located 27 inches (686 mm) maximum above the finished f Exceptions: 84 pdf_text
1 1. Revise Section 706.1.1 to read: "706.1.1 Party walls. Any wall located on a property line between adjacent buildings, which is used or adapted for joint service between t buildings, shall be constructed as a fire wall in accordance with Section 706. Party walls shall be constructed without shall create separate buildings. Exceptions: 57 pdf_text
1 1. Revise Section 1027.2 to read: "1027.2 Use in a means of egress. Exterior exit stairways shall not be used as an element of a required means of egress for Group I-2 occupancies. For other than Group I-2, exterior exit stairways and exterior exit ramps shall be permitted as an element of a required m for levels not more than 45 feet (13.7 m) above grade adjacent to the exterior exit stairway. 103 pdf_text
1 1. Revise Section 1709.1 to read: "1709.1 General. Where proposed construction is not capable of being designed by accepted engineering practices, or where the propo construction design method does not comply with the applicable material design standard, the system of construction structural unit and the connections shall be subjected to the tests prescribed in Section 1709. The building official sha certified reports of such tests conducted by an approved agency, provided that such tests meet the requirements of thi specified procedures." 162 pdf_text
1 1. Building height shall be measured to the highest walking surface of an occupiable rooftop the highest story. 17 pdf_text
1 1. Revise Section 804.4.2 to read: "804.4.2 Minimum critical radiant flux. In all occupancies, interior floor finish and floor covering materials within enclosures for interior exit stairways, inte ramps, exit passageways, lobbies which are part of the exit discharge, corridors and rooms or spaces not separated fr by partitions extending from the floor to the underside of the ceiling shall withstand a minimum critical radiant flux. critical radiant flux shall be not less than Class I throughout Groups I-1, I-2, I-3 and R-4, not less than Class I within interior exit stairways, interior exit ramps, exit passageways and lobbies which are part of the exit discharge in Grou H, I-4, M, R-1, R-2 and S, and not less than Class II in corridors and spaces not separated from corridors by partitio from the floor to the underside of the ceiling in Groups A, B, E, F, H, I-4, M, R-1, R-2 and S. Exception: In areas other than within enclosures for interior exit stairways, interior exit ramps or exit passag lobbies which are part of the exit discharge, where a building is equipped throughout with an automatic sprin accordance with Section 903.3.1.1 or 903.3.1.2, Class II materials are permitted in any area where Class I ma required and materials complying with DOC FF-1 "pill test" (CPSC 16 CFR Part 1630) or with ASTM D285 in any area where Class II materials are required." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 27; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 12) 65 pdf_text
1 1. Delete Section 414.1 and its subsections. 32 pdf_text
1 1. The ceiling height in both the remote room and adjoining room shall be no less than 9 feet mm) at the lowest point. 123 pdf_text
1 1. Operable windows where the bottom of the clear opening is located more than 75 feet (22 860 mm finished grade or other surface below and that are provided with window fall prevention devices that c ASTM F2006. 100 pdf_text
1 1. ON-AUTO-OFF control over each individual piece of operating smoke control equipment controlled from other sources within the building. This includes stairway pressurization fans; s fans; supply, return and exhaust fans; elevator shaft fans and other operating equipment used o smoke control purposes. 226 pdf_text
1 1. The loft shall have a floor area of not less than 35 square feet (3.25 m2) and not more than 150 squ m2). 125 pdf_text
1 1. Revise Section 409.3.3 by replacing "approved" with "intended." 31 pdf_text
1 1. Delete Section 411.5. 32 pdf_text
1 1. Revise Table 716.1(2) by changing the rows for the first two types of assemblies as shown: Revisions to TABLE 716.1(2) TYPE OF ASSEMBLY REQUIRED WALL ASSEMBLY RATING (hours) MINIMUM FIRE DOOR AND FIRE SHUTTER ASSEMBLY RATING (hours) DOOR VISION PANEL SIZE b FIRE-RATED GLAZING MARKING DOOR VISION PANEL c, e MINIMUM SIDELIGHT/ TRANSOM ASSEMBLY RATING (hours) FIRE-RATE MARKING TRANSO Fire protection Fire resistance Fire protection TYPE OF ASSEMBLY REQUIRED WALL ASSEMBLY RATING (hours) MINIMUM FIRE DOOR AND FIRE SHUTTER ASSEMBLY RATING (hours) DOOR VISION PANEL SIZE b FIRE-RATED GLAZING MARKING DOOR VISION PANEL c, e MINIMUM SIDELIGHT/ TRANSOM ASSEMBLY RATING (hours) FIRE-RAT MARKING TRANSO Fire protection Fire resistance Fire protection Fire walls and fire barriers having a required fire- resistance rating greater than 1 hour 61 pdf_text
1 1. Revise the first sentence of Section 2512.2 to read: "Only plasticity agents in amounts recommended by the manufacturer shall be added to Portland cement or blended 191 pdf_text
1 1. Revise Section 3111.3.5.1 by replacing "local jurisdiction" with "fire code official." 204 pdf_text
1 1. In provisions adopted by reference, reset the following term in italic type: "foam plastic insulation." 192 pdf_text
1 1. Revise Section 1007.1 by adding the following sentence at the end: "Interlocking or scissor stairways shall be counted as one exit stairway." 91 pdf_text
1 1. Continuous special inspection shall be required during field gluing operations of elements force-resisting system. 159 pdf_text
1 1. Delete the word "approved" wherever it appears. 63 pdf_text
1 1. Revise Section 904.2 to read: "904.2 Where permitted. Automatic fire-extinguishing systems installed as an alternative to the required automatic sprinkler systems of Sectio approved by the fire code official. As a condition of approval, the fire code official may require signs indicating the t alternative automatic fire-extinguishing system be installed in prominent locations at each building entrance." 71 pdf_text
1 1. Anchorage of electrical equipment for emergency power systems and standby power syste assigned to Seismic Design Category C or D. 160 pdf_text
1 1. Revise Section 1808.1 to read: 168 pdf_text
1 1. Where the operation of components is bypassed from the preprogrammed weekly t of power downstream of all disconnects shall be verified weekly by a listed control uni 225 pdf_text
1 1. Revise Section 916.2 to read: "916.2 Permits. Permits shall be required as set forth in the Chicago Fire Prevention Code." 82 pdf_text
1 1. Revise Section 1509.1 to replace "deck" with "roof deck." 138 pdf_text
1 1. Add a new Section 1103.1.1 to read: "1103.1.1 Multiple purposes. An area, room or space that is intended to be occupied at different times for different purposes shall comply with all that are applicable to each of the purposes for which the area, room or space will be occupied." 109 pdf_text
1 1. Revise Section 3001.1 to read: 197 pdf_text
1 1. Revise the first sentence of Section 3309.1 to read: "Structures under construction, alteration or demolition shall be provided with not fewer than one portable fire extin accordance with Section 906 and sized for not less than ordinary hazard as follows:" 210 pdf_text
1 1. Delete Section 412.2.2.1. 32 pdf_text
1 1. Davisson Offset Limit. 172 pdf_text
1 1. Isolated deep foundation elements supporting posts of Group R-3, R-4, R-5 and U occupan exceeding two stories of light-frame construction shall be permitted to be reinforced as require analysis but with not less than one No. 4 bar, without ties or spirals, where detailed so the ele subject to lateral loads and the soil provides adequate lateral support in accordance with Sectio 174 pdf_text
1 1. Revise Section 3312.1 to read: "3312.1 Completion before occupancy. In buildings where an automatic sprinkler system is required by this code, it shall be unlawful to occupy any portion or structure until the automatic sprinkler system installation has been tested and accepted by the fire code official, ex provided in Chapter 7 of the Chicago Construction Codes Administrative Provisions. 210 pdf_text
1 1. Revise Section 1610.1, excluding the exception, to read: "1610.1 General. Foundation walls and retaining walls shall be designed to resist lateral soil loads. Soil loads specified in Table 1610. as the minimum design lateral soil loads unless determined otherwise by a geotechnical investigation in accordance 151 pdf_text
1 1. Revise Section 420.1 to read: "420.1 General. Occupancies in Groups I-1, R-1, R-2, R-3, R-4 and R-5 shall comply with the provisions of Sections 420.1 through 4 other applicable provisions of this code." 34 pdf_text
1 1. Bedrooms shall have exterior openings with a net glazed area of at least 6 percent of the fl room. 123 pdf_text
1 1. In private garages that serve Group R-2, R-3 and R-4 occupancies, van-accessible parking spaces permitted to have vehicular routes, entrances, parking spaces and access aisles with a minimum vertic 112 pdf_text
1 1. Revise Section 1202.1 to read: "1202.1 General. Every space intended for human occupancy shall be provided with natural ventilation in accordance with Section 12 mechanical ventilation in accordance with the Chicago Mechanical Code. Exceptions: 120 pdf_text
1 1. Shops and storerooms located in a Group R-5 occupancy. 70 pdf_text
1 1. Revise Section 1013.1 by deleting "approved." 98 pdf_text
1 1 hour Hydrogen fuel gas rooms, not classified as Group H 46 pdf_text
1 1. Revise Section 3303.1 to read: "3303.1 Procedure. Demolition of any building or structure shall begin at the top thereof, and each story shall be completely razed or de the material therefrom completely removed before demolition work begins on the next lower story, unless an alternat is approved by the building official." 208 pdf_text
1 1. Revise the first sentence of exception 4 to Section 2405.3 to read: "Screens shall not be required in individual dwelling units in Groups R-2, R-3 and R-5 where fully tempered glass is glazing or as both panes in an insulating glass unit, and the following conditions are met:" 187 pdf_text
1 1. Add a new Section 1501.1.1 to read: "1501.1.1 Dormers. Dormers shall either be of the same type of construction as required for the roof assembly in which such dormers are same type of construction as required for the exterior walls of the building." 134 pdf_text
1 1. Exterior cladding, interior and exterior nonbearing walls and interior and exterior v (9144 mm) or less in height above grade or walking surface. 159 pdf_text
1 1. Revise Section 1810.1.2 to read: "1810.1.2 Use of existing deep foundation elements. Deep foundation elements left in place where a structure has been demolished shall not be used for the support of ne unless satisfactory evidence is submitted to the building official, which indicates that the elements are sound and mee requirements of this code. Such elements shall be analyzed by a registered geotechnical engineer using non-destructi material testing, load tested or redriven to verify their capacities. The design load applied to such elements shall be t allowable load as determined by analysis, tests or redriving data." 170 pdf_text
1 1. Assembly (see Section 303): Groups A-1, A-2, A-3, A-4 and A-5. 19 pdf_text
1 1. In provisions adopted by reference, reset the following terms in italic type: "approved"; "light-transmitting plasti "roof covering" and "unit skylight." 195 pdf_text
1 1. Revise item 3 in Section 806.1 to read: "3. Furnishings or other objects shall not be placed to obstruct the means of egress." 65 pdf_text
1 1. Revise Section 1604.2 to read: "1604.2 Strength. Buildings and other structures, and parts thereof, shall be designed and constructed to support the factored loads in lo combinations defined in this code without exceeding the appropriate strength limit states for the materials of constru Alternatively, buildings and other structures, and parts thereof, shall be designed and constructed to support the nomi load combinations defined in this code without exceeding the appropriate specified allowable stresses for the materia construction. Loads and forces for occupancies or uses not covered in this chapter shall be approved by the building official." 144 pdf_text
1 1. Revise Section 1614.1 to read: "1614.1 General. Ice-sensitive structures shall be designed for atmospheric ice loads in accordance with Chapter 10 of ASCE 7." 154 pdf_text
1 1. Revise Section 2103.1, excluding the exception, to read: "2103.1 Masonry units. Concrete masonry units, clay or shale masonry units, stone masonry units, glass unit masonry and AAC masonry unit with Article 2.3 of TMS 602. Architectural cast stone shall conform to ASTM C1364 and TMS 504. Calcium silicate masonry units shall conform to ASTM C73 or C744. Adhered manufactured stone masonry veneer units shall confor 178 pdf_text
1 1. Revise the last sentence of Section 1611.1 to read: "The design rainfall shall be based on a 100-year hourly rainfall rate of 4.03 inches (102 mm)." 151 pdf_text
1 1. Add new Section 2101.2.2 to read: "2101.2.2 Single-wythe exterior walls. Masonry units used in single-wythe exterior walls of buildings containing a Group R occupancy shall be tested in ac ASTM E514 and shall have integral water repellant included in the manufacturing process. Exception: Grade SW clay or shale masonry units. Mortar used in single-wythe exterior walls of buildings containing a Group R occupancy shall have a compatible wat added to the mixture." (Amend Coun. J. 10-7-20, p. 21791, Art. II, § 30) 178 pdf_text
1 1. Revise item 3 in the exception to Section 410.2.1 by deleting "approved." 31 pdf_text
1 1. Revise Section 3308.1 to read: "3308.1 General. The temporary use of streets or public property for the storage or handling of materials or of equipment required for 209 pdf_text
1 1 UL S-13 UL UL UL UL 38 pdf_text
1 1. Add a new exception to Section 713.4 to read: "Exception: Where shafts contain only noncombustible pipes, noncombustible conduit or iron, steel or aluminum du floor penetrations not exceeding 9 square feet (0.8 m2) per story, the shaft enclosures connecting any number of stori fire-resistance rating of not less than 1 hour." 60 pdf_text
1 1 hour Refrigerant machinery room 46 pdf_text
1 1. Delete the cross-reference to provisions of the IBC following each reference. 216 pdf_text
1 1. Revise Section 1803.1 by replacing "registered design professional" with "registered geotechnical engineer." 163 pdf_text
1 1. Combustible exterior wall coverings shall not exceed 10 percent of an exterior wall surface area separation distance is 15 feet (4572 mm) or less. 131 pdf_text
1 1. Where stairways connect stepped aisles to cross aisles or concourses, stairway landings ar 96 pdf_text
1 1. Delete the exception to Section 704.1. 51 pdf_text
1 1 hour Group I-3 cells and Group I-2 patient rooms equipped with padded surfaces 46 pdf_text
1 1. The basic design wind speed, V, for use in the design of Risk Category I structures shall be 101 m 149 pdf_text
1 1. Revise Section 1901.2 by replacing "Seismic Design Category C, D, E or F" with "Seismic Design Category C or 176 pdf_text
1 1. The occupant load, number of dwelling units and common path of egress travel distance do not ex in Table 1006.3.3(1). 89 pdf_text
1 1. An accessible route is not required to a basement, second story above grade plane or mezz an area of not more than 1,000 square feet (93 m2) and is either the second story of a two- stor mezzanine of a one-story building, or the basement of a one- or two-story building. This except apply to: 110 pdf_text
1 1 hour and provide automatic sprinkler system In ambulatory care facilities, laboratories not classified as Group H 46 pdf_text
1 1. Walls A/Aw = 0.00100 221 pdf_text
1 1. In no case shall grade plane be lower than the top of the established curb at the midpoint of the fr line of the lot on which the building is located. 17 pdf_text
1 1. Delete the exception to Section 711.2.3. 59 pdf_text
1 1. Revise Section 912.2 to read: "912.2 Location. With respect to hydrants, driveways, buildings and landscaping, fire department connections shall be so located that t apparatus and hose connected to supply the system will not obstruct access to buildings for other fire apparatus. At le department connection shall be provided on each street exposure where the building is located closer than 100 feet (3 curb. If any street exposure is more than 250 feet (76.2 m) long, there shall be two fire department connections at lea (61.0 m) apart. Where a building has no street frontage, the fire department connection shall be located at the main e location of fire department connections shall be reviewed and accepted by the fire code official. Exceptions: 80 pdf_text
1 1. Revise the exceptions to Section 1613.1 to read: 151 pdf_text
1 1. Revise Section 15010.1 and its subsections to read: "1510.1 General. The provisions of this section shall govern the construction of unoccupied rooftop structures. 138 pdf_text
1 1. Spiral stairways used as a means of egress from technical production areas. 97 pdf_text
1 1. Revise Section 301.1 to read: 18 pdf_text
1 1 hour Laundry rooms over 100 square feet 46 pdf_text
1 1. On the ceiling or wall outside of and within 15 feet (4572 mm) of each room used for sleeping pur 75 pdf_text
1 1 hour Storage rooms over 100 square feet in ambulatory care facilities and Group A, E, I, R-1, R-2, R-3 or R-4 occupancies 46 pdf_text
1 1. In provisions adopted by reference, reset the following term in italic type: "ambulatory care facilities" and "fire a 34 pdf_text
1 1. In buildings and structures assigned to Seismic Design Category C, special structural steel elements are not required for seismic force-resisting systems wit modification coefficient, R, of 3 or less. 159 pdf_text
1 1. The canopy and its supports shall be of noncombustible material. Exception: Any textile covering for the canopy shall be flame resistant as determined by tests accordance with NFPA 701 after both accelerated water leaching and accelerated weathering. 218 pdf_text
1 1. In every required interior exit stairway, a hose connection shall be provided for each story above a grade plane. Hose connections shall be located at the floor landing. 72 pdf_text
1 1. Opening protectives are not required where the roof assembly of the adjacent building has resistance rating of not less than 2 hours for a minimum distance of 15 feet (4572 mm) horizo exterior wall facing the imaginary line and the entire length and span of the supporting elemen resistance-rated roof assembly has a fire-resistance rating of not less than 2 hours. 56 pdf_text
1 1. Delete the exceptions to Section 1029.1.1.1. 105 pdf_text
1 1. Revise the list in Section 312.1 to read: "Agricultural buildings Equipment structures with a gross floor area of less than 1,500 square feet (139 m2) Lumber yards (open exterior type only) Parking facilities Private garages and carports Stables" 23 pdf_text
1 1. Door closers and stops that project no more than 4 inches (102 mm) shall not reduce headroom to inches (1981 mm). 84 pdf_text
1 1. Revise Section 707.3.2 by replacing "Section 1023.1" with "Section 1023.2." 58 pdf_text
1 1. Where the air infiltration rate in a dwelling unit is less than 5 air changes per hour where te blower door at a pressure 0.2 inch w.c. (50 Pa) in accordance with the Chicago Energy Conser the dwelling unit shall be ventilated by mechanical means in accordance with Section 403 of t Mechanical Code. 120 pdf_text
1 1. Add new Sections 905.2.1, 905.2.2, 905.2.3 and 905.2.4 to read: "905.2.1 Water supply. Where wet standpipes are installed in buildings that are 80 feet (24.4 m) or less in building height and the building is throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2, the water supply f may be designed to provide 100 pounds per square inch (689 kPa) pressure with 500 gallons per minute (31.6 L/s) fl two hydraulically most remote outlets in the standpipe system. The standpipe system shall be designed for full stand accordance with NFPA 14. 71 pdf_text
1 1. Construction materials and systems that are approved as alternatives to materials and systems pres code. 157 pdf_text
1 1. Revise Section 1405.1.1 to read: "1405.1.1 Types I, II, III and IV construction. On buildings of Types I, II, III and IV construction, exterior wall coverings shall be permitted to be constructed of c materials, complying with the following limitations: 131 pdf_text
1 1. Revise the exception to Section 413.2 to read: "Exception: Neither fire-resistance-rated construction nor opening protectives are required in any of the following lo 32 pdf_text
1 1. Revise Section 1021.4 to read: "1021.4 Location. Exterior egress balconies shall have a minimum fire separation distance of 10 feet (3048 mm) measured at right angl exterior edge of the egress balcony to: 102 pdf_text
1 1. Revise Section 503.1 to read: "503.1 General. Unless otherwise specifically modified in Chapter 4 and this chapter, building height, number of stories above grade building area shall not exceed the limits specified in Sections 504 and 506 based on the type of construction as deter 36 pdf_text
1 1. Revise Section 803.3 to read: "803.3 Heavy timber exemption. In buildings protected throughout by an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1. portions of structural elements complying with the requirements for heavy timber construction in Section 602.4 or Se shall not be subject to interior finish requirements except in interior exit stairways, interior exit ramps, and exit pass 64 pdf_text
1 1. Delete the last sentence of Section 2113.3. 180 pdf_text
1 1. Revise Section 304.1 to replace "Electronic data processing" with "Electronic data processing (with routine huma occupancy)." 19 pdf_text
1 1. Compressed gas piping systems other than fuel gas piping systems where in accord Chicago Fire Prevention Code. 213 pdf_text
1 1. During erection of ductwork and prior to concealment for the purposes of leakage t recording of device location. 227 pdf_text
1 1. Revise Section 1704.2 to read: "1704.2 Special inspections and tests. Where application is made to the building official for construction as specified in Chapter 4 of the Chicago Construc Administrative Provisions, the owner shall employ one or more special inspection agencies to provide special inspec during construction on the types of work specified in Section 1705 and identify the special inspection agencies to the official. These special inspections and tests are in addition to the inspections by the building official that are identifie 155 pdf_text
1 1 H-3 NS c, d UL 38 pdf_text
1 1. Required exterior openings are permitted to open into an open porch or exterior ba the open porch or exterior balcony meets all of the following criteria: 123 pdf_text
1 1. ON-OFF and OPEN-CLOSE control actions shall have the highest priority of any control the building. Once issued from the fire fighter’s control panel, automatic or manual control fro control point within the building shall not contradict the control action. Where automatic mean to interrupt normal, nonemergency equipment operation or produce a specific result to safegua or equipment including, but not limited to, duct freezestats, duct smoke detectors, high-temper temperature-actuated linkage and similar devices, such means shall be capable of being overri fire fighter’s control panel. The last control action as indicated by each fire fighter’s control pa position shall prevail. Control actions shall not require the smoke control system to assume m configuration at any one time. Exception: Power disconnects required by the Chicago Electrical Code. 226 pdf_text
1 1. In provisions adopted by reference, reset the following term in italic type: "marquee." 204 pdf_text
1 1. Fans, dampers and other operating equipment in their normal status – WHITE. 226 pdf_text
1 1. Revise Section 1806.1 by replacing "Table 1806.2" with "Table 1806.2(1) or 1806.2(2), as applicable" and deleti sentence. 165 pdf_text
1 1. Delete Section 1703.1 and its subsections. 155 pdf_text
1 1. Exit signs and means of egress illumination required by Chapter 10. 25 pdf_text
1 1. Windows in bathrooms and kitchens. 119 pdf_text
1 1. Replace Table 602 as shown: TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DI g 48 pdf_text
1 1. Add a new Section 1180.2.9.2 to read: "1108.2.9.2 Raised platform. In banquet rooms or spaces where a head table or speaker’s lectern is located on a raised platform, an accessible rout provided to the platform. Open edges of a raised platform shall be protected by placement of tables or by a curb." 118 pdf_text
1 1. Delete exception 1 to Section 508.1. 44 pdf_text
1 1. Revise Section 1208.1 to read: "1208.1 Crawl spaces. Crawl spaces shall be provided with not less than one access opening that shall be not less than 24 inches by 24 inch 126 pdf_text
1 1. Curved stairways in accordance with Section 1011.9. 96 pdf_text
1 1. Places of detention or restraint. 94 pdf_text
1 1. Means of egress components only serving an occupiable rooftop. 103 pdf_text
1 1. Revise Section 3102.1 by replacing "the International Fire Code" with "Section 3103." 201 pdf_text
1 1. The structure is classified as Risk Category IV. 157 pdf_text
1 1. Complex systems, where approved, where the controls and indicators are combine and indicate all elements of a single smoke zone as a unit. 226 pdf_text
1 1. Revise Section 1001.1 by replacing "an approved" with "a." 84 pdf_text
1 1. Add a new exception 3 to Section 1105.1 to read: "3. In multi-story housing, at least 50 percent of all public entrances shall be accessible." 111 pdf_text
1 1. On floors containing only Group R occupancies, the pressure differential is permitted to be between the hoistway and a dwelling unit or sleeping unit. 230 pdf_text
1 1. Revise exception 1 to Section 2406.3 to read: "1. For other than tempered glass, manufacturer’s designations are not required where the use of a certificate, affida evidence confirming compliance with this code is approved by the building official." 188 pdf_text
1 1. Control wiring and power wiring located outside of a 2-hour fire barrier co be protected using any one of the following methods: 229 pdf_text
1 1. Exterior exit stairways, porches and exterior exit ramps serving not more than 4 stories or rooftops in Group R-2, R-3 and R-5 occupancies shall have a minimum separation distance of mm) if constructed of combustible materials; a separation distance is not required for exterior porches and exterior exit ramps constructed of entirely noncombustible materials. 104 pdf_text
1 1. In provisions adopted by reference, reset the following terms in italic type: "ambulatory care facility"; "emergenc system"; "high-rise building" and "standby power system." 196 pdf_text
1 1. Insect screens shall not be required where other effective means of insect protection, such or insect repellant fans are provided. 127 pdf_text
1 1. Revise Table 1106.1 by replacing "2% of total" with "2% of total (rounded up to nearest whole number)." 111 pdf_text
1 1. Vinyl, or horizontal aluminum siding applied over a weather-resistive barrier as specified in this c 129 pdf_text
1 1. Buildings of Group R-5 occupancy. 69 pdf_text
1 1. The structure is classified as "enclosed" in accordance with Chapter 26 of ASCE 7. 149 pdf_text
1 1. Temporary structures associated with ongoing construction activity shall not be subject to limit. 201 pdf_text
1 1. Revise item 2 of Section 2605.2 by replacing "50 feet (15 240 mm)" with "40 feet (12 190 mm)" and "grade" wit plane." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 89) 194 pdf_text
1 1. Revise Section 1005.2 by adding the following sentence at the end: "The width of means of egress components shall be measured in the clear at the narrowest point of the means of egre under consideration, excepting projections permitted by this chapter." 87 pdf_text
1 1. Group A-1 occupancies. 82 pdf_text
1 1. A site plan of the entire planned development identifying the location of units required to comply 116 pdf_text
1 1. The minimum distance between horizontal sliding power-operated doors in a series shall be 48 inc mm). 94 pdf_text
1 1 I-2, Condition 1 NS f UL 38 pdf_text
1 1. Revise Section 1503.1 by deleting "approved." 135 pdf_text
1 1. Delete Section 408.9. 31 pdf_text
1 1. The toilet room shall be separated from the remainder of the building by fire-resistance-rated cons meeting the requirements of Section 1020.1. 102 pdf_text
1 1 H-2 NS c, d UL 38 pdf_text
1 1. Revise Section 1705.1.1 to read: "1705.1.1 Special cases. Special inspections and tests may be required by the building official or registered design professional for proposed the opinion of the building official or registered design professional, unusual in its nature, such as, but not limited to, examples: 157 pdf_text
1 1. Outdoor areas accessed exclusively for maintenance need only have one means of egress. 86 pdf_text
1 1. The heat alarm or heat detector shall be rated for the ambient environment. 75 pdf_text
1 1. Within a dwelling unit. 97 pdf_text
1 1. Revise Section 3301.1 to read: "3301.1 Scope. The provisions of this chapter shall govern safety during construction, demolition and rehabilitation work and the pr adjacent public and private properties. Provisions of this chapter pertaining to dust control shall be enforced by the C Sustainability Officer in accordance with Chapter 11-4 of the Municipal Code." 207 pdf_text
1 1. For columns, one-twelfth the smallest dimension of cross section with a minimum thickness of 3/ 182 pdf_text
1 1. Golf facilities. 119 pdf_text
1 1. Add a new exception 8 to Section 1015.2 to read: "8. On the loading side of passenger platforms for fixed guideway transit and passenger rail systems." 99 pdf_text
1 1. Revise Section 302.1 to read: "302.1 Occupancy classification. Occupancy classification is the formal designation of the primary purpose of the building, structure or portion thereo shall be classified into one or more of the occupancy groups listed in this section based on the nature of the hazards a occupants generally associated with the intended purpose of the building. Structures that are not buildings shall be cl Group U. An area, room or space that is intended to be occupied at different times for different purposes shall compl applicable requirements associated with each potential purpose. Buildings containing multiple occupancy groups sha 19 pdf_text
1 1. be unobstructed and shall have an area of not less than 8 percent of the floor area o room or space, but not less than 25 square feet (2.3 m2). 121 pdf_text
1 1. Revise Section 504.1, excluding the exception, to read: "504.1 General. The allowable building height, in feet, and the allowable number of stories above grade plane of a building shall be based on the type of construction, occupancy classification and whether there is an automatic sprinkler system install the building." 36 pdf_text
1 1. Revise Section 2305.2 by replacing "approved method" with "accepted engineering practice." 185 pdf_text
1 1. Revise Section 3306.1 to read: "3306.1 Protection required. Pedestrians shall be protected during construction, rehabilitation and demolition activities as required by this chapter A of Chapter 10-28 of the Municipal Code." 209 pdf_text
1 1. Where a building has more than two street exposures, fire department connections are only two of the street exposures. 81 pdf_text
1 1. Revise Section 1110.4.7 to read: "1110.4.7 Animal containment areas. Animal cages, pens, corrals, and similar areas in which animals are contained shall be on an accessible route but shal be required to comply with these requirements. Public circulation routes where animals may travel, such as in petting passageways alongside animal pens in state fairs, are not eligible for this exception." 119 pdf_text
1 1. The lower roof assembly within 15 feet (4572 mm) horizontally of the fire wall has not les fire-resistance rating and the entire length and span of supporting elements for the rated roof a fire-resistance rating of not less than 2 hours. 58 pdf_text
1 1. Revise Section 3202.1.1 to read: "3202.1.1 Structural support. A part of a building erected below grade that is necessary for structural support of the building or structure shall not the property lines, except as provided in Sections 3202.1.1.1 through 3202.1.1.4." 206 pdf_text
1 1. Revise Section 311.2 to insert, alphabetically: "Computers and office machines." 23 pdf_text
1 1. Revise Section 1904.1 by replacing "Group R-2 and R-3" with "Group R." 177 pdf_text
1 1. Revise Section 1609.1.1 to read: "1609.1.1 Determination of wind loads. Wind loads on every building or structure shall be determined in accordance with Chapters 26 to 30 of ASCE 7. The wind speed, V, and the exposure category for a site shall be determined in accordance with Section 1609. Wind shall come from any horizontal direction and wind pressures shall be assumed to act normal to the surface considered. Exceptions: 148 pdf_text
1 1. Revise Section 2501.2 to read: "2501.2 Other materials. Other wall or ceiling coverings may be approved by the building official and, if so, shall be installed in accordance w recommendations of the manufacturer and the conditions of approval." 190 pdf_text
1 1. Throughout the provisions adopted by reference, replace the term "fire district" with "fire limits." 217 pdf_text
1 1. Revise the definition of "accessible" to read: "ACCESSIBLE. A site, building, facility or portion thereof that complies with Section 907.5.2.3, Chapters 10 and 1 Appendix E." 3 pdf_text
1 1. In provisions adopted by reference, reset the following terms in italic type: "fire-resistance rating" and "light- tra plastic roof panels." 195 pdf_text
1 1. Revise item 2 in the exception to Section 403.1 to read: "2. Parking facilities in accordance with Section 406.9." 24 pdf_text
1 1. One-story buildings. 134 pdf_text
1 1. Revise the exception to Section 1603.1 by deleting item 5. 144 pdf_text
1 1. Revise Section 3201.1 by replacing "public right-of-way" with "public way." 205 pdf_text
1 1. In provisions adopted by reference, reset the following terms in italic type: "greenhouse" and "light-transmitting panels." 194 pdf_text
1 1. Revise Section E101.1 to read: "E101.1 Scope. The provisions of this appendix shall control the supplementary requirements for the design and construction of facil accessibility for individuals with disabilities." 219 pdf_text
1 1. Delete Section 303.1.4. 19 pdf_text
1 1. Revise Section 2204.3 by replacing "approved" with "permitted." 181 pdf_text
1 1. Equipment, control wiring, power wiring and ductwork shall be located exterior to and directly connected to the smokeproof enclosure or connected to the smokeproof en ductwork enclosed by not less than 2-hour fire barriers constructed in accordance with horizontal assemblies constructed in accordance with Section 711, or both. 229 pdf_text
1 1. Delete the exception to Section 2611.1. 195 pdf_text
1 1. The aggregate area of mezzanines in buildings of Type I or II construction for special indu occupancies in accordance with Section 503.1.1 shall be not greater than two-thirds of the floo room. 40 pdf_text
1 1. Welding operations of elements of the seismic force-resisting system. 159 pdf_text
1 1. Revise the exception to Section 1109.1 to read: "Exception: Accessible units, Type A units, Type B units and Type C units shall comply with Chapter 10 of ICC A11 118 pdf_text
1 1. Revise the title of Section 717.1.1 to "Transfer ducts." 62 pdf_text
1 1. Revise Section 1504.1.1 to read: "1504.1.1 Wind resistance of asphalt shingles. Asphalt shingles shall be tested in accordance with ASTM D7158 and have a classification of D, G or H. Asphalt shi shall bear a label to indicate compliance with ASTM D7158 and the required classification. Exception: Asphalt shingles not included in the scope of ASTM D7158 shall be tested and labeled in accord ASTM D3161 and have a classification of A, D or F. Asphalt shingle packaging shall bear a label to indicate with ASTM D3161 and the required classification." 135 pdf_text
1 1. The grade-level tier is allowed to contain an office, waiting and toilet rooms having a total of not more than 1,000 square feet (93 m 2). Such area need not be separated from the parking 31 pdf_text
1 1. Delete Section 703.2.5. 51 pdf_text
1 1. Interior stairways that are not required to comply with Section 1009.3, provided that the o treads does not permit the passage of a sphere with a diameter of 6 inches (152 mm). 96 pdf_text
1 1. Special inspections and tests are not required for construction of a minor nature or as warr conditions approved by the building official. 155 pdf_text
1 1. Single- and multiple-station smoke alarms required by Section 907.2.10. 67 pdf_text
1 1. Concrete or grout in compression b Cast-in-place with a permanent casing in accordance with Section 1810.3.2.7, 171 pdf_text
1 1. Revise Section 2303.1.1 and its subsections to read: "2303.1.1 Sawn lumber. Sawn lumber used for load-supporting purposes, including end-jointed or edge-glued lumber, machine stress- rated o evaluated lumber, shall be identified by the grade mark of a lumber grading or inspection agency accredited by an ac body that complies with DOC PS 20 or approved equivalent. Grading practices and identification shall comply with r by an agency certified in accordance with the procedures of DOC PS 20 or approved equivalent procedures. 183 pdf_text
1 1. For applications listed in Section 1109.8. 118 pdf_text
1 1. Revise Section 719.3 by deleting "approved." 63 pdf_text
1 1. Revise Section 715.1 by replacing "an approved" with "a." 60 pdf_text
1 1. Revise section 1023.2 by replacing "basements" with "basements and occupiable rooftops (even if not counted a other purposes)." 103 pdf_text
1 1. Revise Section 1805.1 to read: "1805.1 General. Walls or portions thereof that retain earth and enclose interior spaces and floors below grade shall be waterproofed a dampproofed in accordance with this section. Exception: Spaces containing occupancies other than Group A, E, I or R where such omission is not detrime building or occupancy." 165 pdf_text
1 1. A shaft or unenclosed open well is provided to accommodate the future installation residential elevator or lift complying with the Chicago Conveyance Device Code. The shall be structurally sufficient to allow future installation of the elevator or lift without reinforcement or alteration of structural elements. Conduit for future electrical wiring a operation of the elevator or lift shall be provided at the shaft or unenclosed open well. I provided, the space occupied for a shaft is not restricted from being used for other purp the elevator or wheelchair lift is installed. The floor openings within the shaft or unenc well may be in-filled with flooring if the in-fill flooring can be removed at the time of i the elevator or lift without additional reinforcement or alteration of other structural ele Maneuvering clearances at landings where entrances to the elevator or lift occur shall if the width of the corridor, hallway or other space in front of the shaft is not less than mm). 117 pdf_text
1 1. Delete Section 1403.2. 128 pdf_text
1 1. Group I occupancies where the floor area of any story exceeds 8,000 square feet (743 m 2 ). 77 pdf_text
1 1. Revise Section 2207.4 by replacing "approved construction documents" with "permitted construction documents. 181 pdf_text
1 1 I-3 NS d, e UL 38 pdf_text
1 1. In multilevel parking structures, van-accessible parking spaces required by Section 1106.5 are per level. 112 pdf_text
1 1. Revise Section 3004.1 to read: "3004.1 General. Conveyance devices, other than elevators, shall comply with the Chicago Conveyance Device Code and the provisio 199 pdf_text
1 1. Revise Section 1006.1 by replacing "occupied roofs" with "occupiable rooftops." 87 pdf_text
1 1. Delete Section 2409.2.2. 189 pdf_text
1 1. Add a new Section 3105.1.1 to read: "3105.1.1 Awnings and canopies over the public way. Awnings and canopies installed over the public way shall also comply with Chapter 32 of this code and Chapter 10-2 Municipal Code." 203 pdf_text
1 1. Roof coverings installed with a slope of 5:12 (41 percent) or greater. 143 pdf_text
1 1. Revise Section 505.2 to read: "505.2 Mezzanines. A mezzanine or mezzanines in compliance with Section 505.2 shall be considered a portion of the story below. Such shall not contribute to the number of stories above grade plane as regulated by Section 503.1. The area of the mezza 39 pdf_text
1 1. Within the rear 60 percent of the seats provided: or 109 pdf_text
1 1. Tubing shall comply with the requirements of the Chicago Mechanical Code. 225 pdf_text
1 1. Add a new Section 3310.3 to read: "3310.3 Floor required. In buildings where construction of the superstructure precedes construction of the permanent floor, a substantial tem shall be constructed at a level not more than two floors below the highest level where work is being performed." 210 pdf_text
1 1. Revise Section 2509.1 to read: "2509.1 Finish materials. Shower areas, bathing areas and public toilet walls shall conform to Section 1209.2." 191 pdf_text
1 1. Revise Section 1701.1 to read: "1701.1 Scope. The provisions of this chapter shall govern the quality, workmanship and requirements for materials covered. Constr materials and test procedures shall conform to the applicable standards listed in this code and the other Chicago Con Codes." 154 pdf_text
1 1. Where more than 50 percent of the roof area is a vegetative roof or roof garden, th the roof area shall have a three-year-aged solar reflectance value of 0.3 or greater. 143 pdf_text
1 1 hour In Group I-2 occupancies, laboratories not classified as Group H 46 pdf_text
1 1. Revise Section 3007.1, including its exception, to read: "3007.1 General. Where required by Section 403.6.1, every area of every story of the building shall be served by a fire service access complying with Sections 3007.1, 3007.5, 3007.6.5, 3007.7, and 3007.8. Except as modified in this section, fire servi elevators shall be installed in accordance with this chapter and the Chicago Conveyance Device Code." 200 pdf_text
1 1. Revise Section 1606.2 to read: "1606.2 Design dead load. For purposes of design, the actual weights of materials of construction and fixed equipment shall be used. In the abse information, values used shall be approved by the building official." 146 pdf_text
1 1. From a height of 36 inches (914 mm) to 42 inches (1067 mm), guards shall not have openings that of a sphere 6 inches (152 mm) in diameter. 99 pdf_text
1 1. Airport traffic control towers in accordance with Sections 412 and 907.2.21. 76 pdf_text
1 1. Group H occupancies shall not be classified as accessory occupancies and shall be separated from occupancies in accordance with Section 508.4. 44 pdf_text
1 1. Add a new Section 903.1.2 to read: "903.1.2 Where prohibited. Automatic sprinkler systems shall not be installed in hazardous chemical rooms or in hazardous chemical storage buil the chemical has the ability to react with water to produce substances or violent chemical reactions which increase th When the presence of water will not add to the hazard, an automatic sprinkler system shall be required in such hazar room or building." 67 pdf_text
1 1. Revise Section 2110.1.1, excluding the exception, to read: "2110.1.1 Limitations. Solid or hollow glass block shall not be used in fire walls, party walls, fire barriers, fire partitions or smoke barriers, bearing construction. Glass blocks shall be erected with mortar and reinforcement in metal channel-type frames, stru masonry or concrete recesses, embedded panel anchors as provided for both exterior and interior walls or other appr materials. Wood strip framing shall not be used in walls required to have a fire-resistance rating by other provisions 179 pdf_text
1 1. Revise Section 910.2, excluding the exceptions, to read: "910.2 Where required. Smoke and heat vents or a mechanical smoke removal system shall be installed as required by Sections 910.2.1 throu 79 pdf_text
1 1. Revise exception 1 to Section 1012.6.3 by replacing "Group R-2 and R-3" with "Group R-2, R-3 and R-5." 98 pdf_text
1 1. Revise Section 1506.3 by replacing "approved testing agency" with "approved agency." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 68) 136 pdf_text
1 1. Revise Section 1706.1 to read: "1706.1 Conformance to standards. The design strengths and permissible stresses of any structural material that are identified by a manufacturer’s desig manufacture and grade by mill tests, or the strength and stress grade is otherwise confirmed to the satisfaction of the official, shall conform to the specifications and methods of design of accepted engineering practice or be approved in with Chapter 10 of the Chicago Construction Codes Administrative Provisions." 161 pdf_text
1 1. The closest abutting property line. 9 pdf_text
1 1. Revise Section 407.3 to read: "407.3 Corridor wall construction. Corridor walls shall be constructed as smoke barriers in accordance with Section 709." 31 pdf_text
1 1. Revise the exception to Section 1104.1 to read: "Exception: Other than in buildings or facilities containing or serving Type B units, an accessible route shall not be between site arrival points and the building or facility entrance if the only means of access between them is a vehicul providing for pedestrian access. Access from site arrival points is permitted to include vehicular ways. Where a vehic portion of a vehicular way is provided for pedestrian travel, such as within a shopping center or shopping mall parki exception shall not apply." 110 pdf_text
1 1. Revise the exception to Section 1906.1 by replacing "Group R-3" with "Groups R-3 and R-5." 177 pdf_text
1 1. Revise Section 3302.1, excluding the exceptions, to read: "3302.1 Alterations, repairs and additions. Required means of egress components, existing structural elements, fire protection devices and sanitary safeguards s maintained at all times during alterations, repairs or additions to any building or structure." 208 pdf_text
1 1. Revise Section 1203.1, excluding the exceptions, to read: "1203.1 Heating equipment and systems. Interior spaces intended for human occupancy shall be provided with active or passive space heating systems capable maintaining an indoor temperature of not less than 68°F (20°C) at a point 3 feet (914 mm) above the floor when the temperature is -7°F (-22°C)." 122 pdf_text
1 1. Add a new Section 3304.2 to read: "3304.2 Drainage across property lines. Drainage across property lines shall not exceed that which existed prior to site work. Excess or concentrated drainag contained on site or directed to a permitted drainage facility. Erosion of the ground in the area of discharge shall be p installation of nonerosive down drains or similar devices." 209 pdf_text
1 1. Governmental facilities which contain or provide administrative services available to the general p 111 pdf_text
1 1. In provisions adopted by reference, reset the following term in italic type: "24-hour basis" and "custodial care." 21 pdf_text
1 1. Revise Section 1002.1 to read: "1002.1 Maintenance. Means of egress shall be maintained in accordance with the Chicago Minimum Requirements for Existing Buildings a Fire Prevention Code." 84 pdf_text
1 1. Revise item 1 of Section 1809.5 to read: "1. Extending at least 42 inches (1067 mm) below final grade." 169 pdf_text
1 1. Revise Section 1408.1 to read: "1408.1 General. The provisions of this section shall govern the materials, construction and quality of High-Pressure Decorative Exter Compact Laminates (HPL) for use as exterior wall coverings in addition to other applicable requirements of Chapter 133 pdf_text
1 1 hour Waste, recycling and linen collection rooms with containers that have an aggregate volume of 10 cubic feet or greater in ambulatory care facilities or Group I-2 occupancies 46 pdf_text
1 1. Add new exceptions 3 and 4 to item 1 in Section 906.1 to read: "3. In Group R-2 occupancies not more than three stories above grade plane and having a floor area not exc square feet (279 m 2 ). 73 pdf_text
1 1 foot (305 mm) or fraction thereof in height up to a maximum width of 15 feet (4572 mm). Openings on opp an outer court shall be separated by not less than 6 feet (1829 mm). 124 pdf_text
1 1. On buildings of Type I and II-A construction, the exterior walls and roof decks of mechan penthouses with a fire separation distance greater than 5 feet (1524 mm) and less than 20 feet shall be noncombustible construction and permitted to have not less than a 1-hour fire-resistan 138 pdf_text
1 1. Revise Section 1204.1 to read: "1204.1 General. Every space intended for human occupancy shall be provided with natural light in accordance with Section 1204.2 or provided with artificial light in accordance with Section 1204.3. Exceptions: 122 pdf_text
1 1. Passive smoke control systems with automatic-closing devices actuated by spot-typ detectors listed for releasing service installed in accordance with Section 907.3. 222 pdf_text
1 1. Delete Section 2612.4. 195 pdf_text
1 1. Revise Section 1502.1 to read: "1502.1 General. Design and installation of roof drainage systems shall comply with Section 1502 of this code and Section 1106 of the Plumbing Code." 134 pdf_text
1 1. All panels shall be located in the line of sight immediately inside the primary entrance to the build facing the street of the building address. The building address number shall be conspicuously displaye next to the primary entrance doors. 79 pdf_text
1 1. More than 6 feet (1829 mm) above grade plane; or 15 pdf_text
1 1. Detached single-family dwellings shall comply with Section 1107.8.4. 116 pdf_text
1 1. Revise Section 3005.1 by replacing "An approved" with "Acceptable." 199 pdf_text
1 1. A temporary covered passageway, no more than 8 feet (2438 mm) wide, with open sides, may be provided to connect temporary structures to existing buildings. 202 pdf_text
1 1. Revise item 3 in Section 1024.6 to read: "3. Security systems covering the exit passageway." 103 pdf_text
1 1. Revise note e to Table 307.1(1) to delete "approved" and "Section 5003.9.10 of." 20 pdf_text
1 1. In each mechanical equipment, electrical, transformer, telephone equipment or similar room that i with sprinkler protection. 76 pdf_text
1 1. Revise Section 720.5 by replacing "approved roof coverings" with "a Class A or Class B roof covering." 63 pdf_text
1 1. Revise Section 1804.2.1 by replacing "approved" with "permitted." 164 pdf_text
1 1. Replace Table 601 as shown: TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) 47 pdf_text
1 1. Walls in which the water-resistive barrier or air barrier required by the Chicago Energy C Code is the only combustible component and the exterior wall has an exterior wall covering o concrete, stone, terracotta, stucco or steel with minimum thicknesses in accordance with Table 128 pdf_text
1 1. Geotechnical investigations are not required for single-story storage structures without basements private garages not exceeding 2,000 square feet (185.8 m2). 163 pdf_text
1 1. Revise Section 502.1 to read: "502.1 Address identification. Address identification shall be provided in accordance with Chapter 10-4 of the Municipal Code." 35 pdf_text
1 1. Where the number of required Type A units exceeds the number of dwelling units a units and at least one bedroom in each dwelling unit and sleeping unit is a Type A unit, bedroom in each dwelling unit and sleeping unit may count toward the number of requi units. 114 pdf_text
1 1. Replace Table 509 as shown: TABLE 509 INCIDENTAL USES ROOM OR AREA SEPARATION AND/OR PROTECTION ROOM OR AREA SEPARATION AND/OR PROTECTION Furnace room where any piece of equipment is over 400,000 Btu per hour input 46 pdf_text
1 1. The number of Type A units is permitted to be reduced in accordance with S exceptions allowed for Type B units. 114 pdf_text
1 1. Revise exception 2 to Section 1014.2 by replacing "Group R-3" with "Group R-3 or R-5." 99 pdf_text
1 1. Revise Section 2105.1 by replacing "approved" with "permitted." 179 pdf_text
1 1. Revise Section 722.1 by inserting the following before the first sentence: "The procedures described in Section 722 may only be used where approved by the building official." 63 pdf_text
1 1. Add a new Section 1102.1.1 to read: "1102.1.1 Equivalent facilitation. Nothing in this chapter prevents the use of designs, products or technologies as alternatives to those prescribed, provi in substantially equivalent or greater access and usability for individuals with disabilities." 109 pdf_text
1 1. Delete exception 2 and its subparts to Section 1402.2. 128 pdf_text
1 1. Delete the last sentence of Section 2308.1. 185 pdf_text
1 1. Revise Section 3109.1 by replacing "International Swimming Pool and Spa Code" with "Chicago Plumbing Cod (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 96) 204 pdf_text
1 1. Delete the exception to item 1 in Section 1111.1. 119 pdf_text
1 1. Foam plastic used as interior wall or ceiling finish or interior trim in plenum-served spaces flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in ac ASTM E84 or UL 723 at the maximum thickness and density intended for use, where it is sep airflow in the plenum by a thermal barrier complying with Section 2603.4. 193 pdf_text
1 1. Floor drains, sumps and sump pumps shall be permitted at the base of the hoistway enclos that they are indirectly connected to the plumbing system. 198 pdf_text
1 1. Revise Section 3002.1.2 to read: "3002.1.2 Hardware. Hardware on opening protectives shall be installed as tested, except that interlocks, mechanical locks and electric co gate electric contacts and door-operating mechanisms shall be exempt from the fire test requirements." 198 pdf_text
1 1. Isolated cast-in-place deep foundation elements without lateral bracing shall be permitted horizontal dimension is not less than 30 inches (762 mm), adequate lateral support in accordan 170 pdf_text
1 1. Delete the exception to Section 1026.2. 103 pdf_text
1 1. Revise Section 705.2, its subsections, and related tables to read: "705.2 Projections. Cornices, eave overhangs, exterior balconies, decks and similar projections extending beyond the exterior wall shall requirements of this section and Section 1405. Egress balconies shall comply with Section 1021. Porches, exterior e and exterior exit ramps shall comply with Section 1027. Projections shall not extend any closer to the line used to de separation distance than shown in Table 705.2. Exception: Buildings on the same lot and considered as portions of one building in accordance with Section required to comply with this section for projections between the buildings. TABLE 705.2 MINIMUM DISTANCE OF PROJECTION For SI: 1 foot = 304.8 mm; 1 inch = 25.4 mm. a. Detached private garages and buildings of Group R-3 or R-5 occupancy located within 28 inches (711 mm) of a property line are permitted to have r projections not exceeding 4 inches (102 mm). 52 pdf_text
1 1. Revise Section 1201.1 by deleting "sound transmission." 120 pdf_text
1 1. Revise Section 1209.1 by replacing "Chapter 29" with "the Chicago Plumbing Code." 126 pdf_text
1 1. Metal composite material (MCM) systems complying with Section 1406. 131 pdf_text
1 1. Equipment shall be located so that exhausts do not discharge against combustible material. 214 pdf_text
1 1. Replace each occurrence of "International Codes" with "Chicago Construction Codes." 2 pdf_text
1 1. Delete item 8 in Section 718.2.1. 63 pdf_text
1 1. Four or more care recipients are incapable of self-preservation. 68 pdf_text
1 1. Revise Section 1107.2 to read: "1107.2 Design. Dwelling units and sleeping units that are required to be Accessible units, Type A units, Type B units or Type C units with the applicable provisions of Chapter 10 of ICC A117.1. Units required to be Type A units may be designed and Accessible units. Units required to be Type B units may be designed and constructed as Accessible units or Type A un required to be Type C units may be designed and constructed as Accessible units, Type A units, or Type B units." 112 pdf_text
1 1 hour In Group I-2, physical plant maintenance shops 46 pdf_text
1 1. Delete exception 2 to Section 2510.6. 191 pdf_text
1 1. Revise the last sentence of Section 709.4 to read: "Smoke-barrier walls used to enclose areas of refuge in accordance with Section 1009.6.4 or to enclose elevator lobb accordance with Section 405.4.3, 3007.6.2, or 3008.6.2 shall comply with Section 709.4.2." 59 pdf_text
1 1. A supervising station is not required for automatic sprinkler systems protecting Gr occupancies. 67 pdf_text
1 1. Revise Section 915.1 by replacing "Chapter 11 of the International Fire Code" with "the Chicago Minimum Req Existing Buildings." 81 pdf_text
1 1. Revise Section 1008.2 to read: "1008.2 Illumination required. 91 pdf_text
1 1. Where the floor area of the parking garage exceeds 12,000 square feet (1115 m2). 69 pdf_text
1 1. Revise Section 1508.1 to read: "1508.1 General. 137 pdf_text
1 1. In dwelling units and sleeping units in Group R, I-1, and I-2 occupancies, all living, dining rooms with a floor area of 70 square feet (6.5 m 2 ) or more shall be provided with natural ligh with Section 1204.2 and artificial light in accordance with Section 1204.3. 122 pdf_text
1 1. Revise item 1 of Section 1016.2 by deleting the second sentence. 100 pdf_text
1 1. In Group R-2, R-3 and R-4 occupancies that are required to have Accessible, Type A or Type B dw sleeping units, accessible parking spaces shall be provided in compliance with Table 1106.2. 111 pdf_text
1 1. Revise item 1 and its subparts in Section 603.1 to read: "1. Fire-retardant-treated wood shall be permitted in: 49 pdf_text
1 1. Revise Section 2211.1.1.2 to read: "2211.1.1.2 Seismic Design Category D. In cold-formed steel light-frame construction assigned to Seismic Design Category D the seismic force-resisting syst designed and detailed in accordance with AISI S400." 181 pdf_text
1 1. Revise Section 2403.1 by replacing "approved construction documents" with "permitted construction documents. 187 pdf_text
1 1 hour in Group B, F, M, S and U occupancies; 46 pdf_text
1 1. Revise Section 506.1 and its subsections to read: "506.1 General. The allowable building area of a building shall be determined based on the type of construction, occupancy classific there is an automatic sprinkler system installed throughout the building and the amount of building frontage on a pub yard. 40 pdf_text
1 1. Where the cladding manufacturer has provided installation instructions for application ove sheathing, those requirements shall apply. 193 pdf_text
1 1. Buildings and structures assigned to Seismic Design Category A shall comply with Section 1613. 152 pdf_text
1 1. Revise Section 1608.2 to read: "1608.2 Ground snow load. The ground snow load to be used in determining the design snow loads for roofs shall be 25 pounds per square foot ( 148 pdf_text
1 1. Plasticity index (PI) of 15 or greater, determined in accordance with ASTM D4318. 163 pdf_text
1 1. Exit signs are not required in rooms or areas that require only one exit or exit access. 98 pdf_text
1 1. Revise the exception to Section 419.1 to read: "Exception: Dwelling units or sleeping units that include workspace that is less than 20 percent of the area of the dw 33 pdf_text
1 1. Revise Section 306.2 to replace "Laundries" with "Laundries (other than pick-up and delivery stations and self- s 20 pdf_text
1 1. Revise Section 1905.1.2 by replacing "Seismic Design Category B, C, D, E or F" with "Seismic Design Categor and "Seismic Design Category C, D, E or F" with "Seismic Design Category C or D." 177 pdf_text
1 1. Where interior exit stairways or exit access ramps are interconnected by a 1-hour fire-resis corridor conforming to the requirements of Section 1020, the required separation distance shal along the shortest direct line of travel within the corridor. 91 pdf_text
1 1. Revise the exception to Section 404.2 by deleting "approved." 27 pdf_text
1 1. Revise note a to Table 1017.2 to delete "Section 402: For the distance limitation in malls." 100 pdf_text
1 1. The veneer shall not exceed 40 feet (12 190 mm) in height above grade. 129 pdf_text
1 1. Revise the exception to Section 2511.1 to read: "Exception: Gypsum veneer plaster and cement plaster specifically designed and recommended by the manufacturer applications." 191 pdf_text
1 1. Class I standpipes are allowed in buildings equipped throughout with an automatic sprinkl accordance with Section 903.3.1.1 or 903.3.1.2. 72 pdf_text
1 1. Recommended deep foundation types and installed capacities. 163 pdf_text
1 1. Dwelling units and sleeping units in Group I occupancies shall comply with Section 1107. 115 pdf_text
1 1. A room where the application of water, or flame and water, constitutes a serious life or fire hazard 70 pdf_text
1 1. Revise Section 1708.1 to read: "1708.1 General. Whenever there is a reasonable doubt as to the strength, stability or load-bearing capacity of a completed building, st portion thereof for the expected loads, an engineering assessment shall be required. The engineering assessment shall a structural analysis or an in-situ load test, or both, as determined by the building official. A structural analysis shall actual material properties and other as-built conditions that affect strength, stability or load-bearing capacity, and sha conducted in accordance with the applicable design standard. In-situ load tests shall be conducted in accordance with 162 pdf_text
1 1. If the volume of the atrium does not exceed 600,000 cubic feet (16 990 m 3), the exhaust system s not less than 6 air changes per hour. 78 pdf_text
1 1. Revise the exceptions to Section 1009.2.1 by replacing "an automatic sprinkler system" with "a supervised autom system." 92 pdf_text
1 1. Throughout all Group E fire areas and all connected Group A fire areas in buildings where the ag of all Group E and connected Group A fire areas is 7,200 square feet (669 m2) or greater. 68 pdf_text
1 1. Atriums shall not be allowed within Group H occupancies. 59 pdf_text
1 1. Revise item 2 to section 2608.2, excluding its exception, to read: "2. Flame barriers extending 30 inches (762 mm) beyond the exterior wall in the plane of the floor, or vertic less than 4 feet (1219 mm) in height, shall be installed between glazed units located in adjacent stories." 195 pdf_text
1 1. Delete items 2 and 4 in Section 708.1. 58 pdf_text
1 1. Pickets, handrails and similar vertical elements not more than 4 feet (1219 mm) in the adjacent walking surface of material not less fire resistive than untreated wood or p composites that comply with ASTM D7032 and Section 2612 if the fire separation dis than or equal to 20 feet (6096 mm). 141 pdf_text
1 1. Revise exception 1 to Section 1010.1.1 to read: "1. Within Group R-2, R-3 and R-5 dwelling and sleeping units that are not required to be an Accessible unit or Type B unit, the minimum clear opening width of an exit access doorway, other than the primary entrance t shall be 28 inches (711 mm), and the minimum and maximum width shall not apply to door openings that are required means of egress." 92 pdf_text
1 1. In provisions adopted by reference, reset the following term in italic type: "approved." 195 pdf_text
1 1. Walking surfaces of occupiable rooftops. 142 pdf_text
1 1. Revise Section 1404.2 by deleting "approved." 129 pdf_text
1 1. In provisions adopted by reference, reset the following terms in italic type: "approved"; "greenhouse" and "light- system." 194 pdf_text
1 1. Revise Section 907.1.1 to read: "907.1.1 Construction documents. Construction documents for fire alarm systems shall be of sufficient clarity to indicate the location, nature and extent proposed and show in detail that it will conform to the provisions of this code, the Chicago Electrical Code and the Prevention Code." 73 pdf_text
1 1. Delete the last sentence of Section 2111.3. 179 pdf_text
1 1. For other than fire service access elevators, where machine rooms, machinery spaces, control roo spaces do not abut and do not have openings to the hoistway enclosure they serve, the fire barriers co accordance with Section 707 or horizontal assemblies constructed in accordance with Section 711, or permitted to be reduced to a 1-hour fire-resistance rating. 199 pdf_text
1 1. Revise Section 3101.1 to read: "3101.1 Scope. The provisions of this chapter shall govern special construction including membrane structures, temporary structures walkways and tunnels, automatic vehicular gates, awnings and canopies, marquees, towers, antennas swimming pool and safety devices, solar energy systems, greenhouses and fences." 201 pdf_text
1-1 1-1/2 Not Permitted Enclosures for shafts, interior exit stairways and interior exit ramps 61 pdf_text
1.1 1.1. Revise exception 1.1 to Section 1028.1 by replacing "from the point of termination of the enclosure." with "wit (7620 mm) and no more than two turns, each not exceeding 90 degrees (1.57 rad), from the point of termination of th There shall be no dead-end corridors or similar conditions exceeding 10 feet (3048 mm) in length adjacent to the poi termination of the enclosure." 104 pdf_text
1.1 1.1. The only means of access between them is a vehicular way not providing for pedestrian access. 110 pdf_text
1.1 1.1. Delete Table 1504.1.1. 135 pdf_text
1.1 1.1. Revise exception 3 to Section 1011.2 by replacing "Group R-3" with "Group R-3 or R-5." 95 pdf_text
1.1 1.1. Revise exception 2 to Section 508.1 by replacing "Table 415.6.2" with "the Chicago Fire Prevention Code." 44 pdf_text
1.1 1.1. Revise Section 406.1 by adding a final sentence to read: "Parking facilities shall also comply with Section 406.9." 28 pdf_text
1.1 1.1. Does not penetrate a horizontal assembly that separates fire areas or smoke barriers that compartments. 59 pdf_text
1.1 1.1. Revise Section 901.2 by replacing "reduction to the provisions" with "reduction under the provisions." 66 pdf_text
1.1 1.1. Revise Table 1004.5 by changing the value for "Baggage claim" under "Airport terminal" from "20 gross" to "5 85 pdf_text
1.1 1.1. Shopping centers or shopping malls. 110 pdf_text
1.1 1.1. Nonbearing partitions where the required fire-resistance rating is 1 hour or less. 49 pdf_text
1.1 1.1. Revise row 2 of Table 1607.1 to read: 146 pdf_text
1.1 1.1. Insert a section to read: " AFSI Architectural Fabric Structur Industrial Fabric Association 216 pdf_text
1.1 1.1. Revise Section 308.2 by replacing "Alcohol and drug centers" with "Alcohol and drug abuse treatment facilitie 21 pdf_text
1.1 1.1. Revise Section 1107.3, excluding the exceptions, to read: "1107.3 Accessible spaces. Rooms and spaces available to the general public or available for use by residents and serving Accessible units, Type B units or Type C units shall be accessible. Accessible spaces shall include toilet and bathing rooms, kitchen, living a areas and any exterior spaces, including patios, terraces and balconies." 112 pdf_text
1.1 1.1. Abuts a public way, or a yard or court complying with Section 1205. 123 pdf_text
1.1 1.1. Cables used for survivability of required critical circuits shall be l accordance with UL 2196 and shall have a fire-resistance rating of not l hours. 229 pdf_text
1.2 1.2. Has a ceiling height of not less than 7 feet (2134 mm). 123 pdf_text
1.2 1.2. Where encased with not less than 2 inches (51 mm) of concrete. 229 pdf_text
1.2 1.2. Revise exception 1.3 to Section 1028.1 by deleting "approved." 104 pdf_text
1.2 1.2. Add a new Section 406.1.1 to read: "406.1.1 Covered loading spaces and driveways. Loading spaces and driveways which are used for the storage of unattended motor vehicles and extend more than 5 f into a building shall be classified as parking garages or carports. Exception: Interior parking and loading spaces that occupy no more than 20 percent of the overall floor area or S occupancy and which are separated from other areas by a change in level, curb, guard or other fixed barr 28 pdf_text
1.2 1.2. Stories or mezzanines containing offices of health care providers (Group B or I). 110 pdf_text
1.2 1.2. Delete the entire section for ALI. 216 pdf_text
1.2 1.2. Revise Table 1004.5 by changing the value for “Gaming floors (keno, slots, etc.)” under “Assembly” from “11 gross”. 85 pdf_text
1.2 1.2. Revise Section 1504.4 to read: "1504.4 Ballasted low-sloped roof systems. Ballasted low-sloped roof single-ply roof system coverings installed in accordance with Sections 1507.12 and 1507.1 designed in accordance with Section 1504.8 and ANSI/SPRI RP-4." 135 pdf_text
1.2 1.2. The door is not part of an accessible route as required by Chapter 11. 93 pdf_text
1.2 1.2. Is not concealed within the construction of a wall or a floor/ceiling assembly. 59 pdf_text
1.2 1.2. Due to circumstances outside the control of the owner, either the slope of the finished ground le accessible facilities and buildings exceeds 1:12 or physical or legal restrictions prevent the installatio accessible route. 110 pdf_text
1.3 1.3. Is not open to a corridor in Group I and R occupancies. 59 pdf_text
1.3 1.3. Parking that complies with Section 1106 is provided at each accessible building, facility, elemen 110 pdf_text
1.3 1.3. Delete the entire section for AMCA. 216 pdf_text
1.3 1.3. Passenger transportation facilities and airports (Group A-3 or B). 110 pdf_text
1.3 1.3. The door is not part of an Accessible unit, Type A unit or Type B unit. 93 pdf_text
1.3 1.3. Roof construction, including girders, trusses, framing and decking of one-story buildings that do the height and area limitations for Type IIB construction." 49 pdf_text
1.3 1.3. Electrical circuit protective systems shall have a fire-resistance rat than 2 hours. Electrical circuit protective systems shall be installed in ac their listing requirements. S101.20.6.2 Standby power. Mechanical vestibule and stairway and ramp shaft ventilation systems and automatic fire detection sy provided with standby power in accordance with Section 2702. S101.20.6.3 Acceptance and testing. Before the mechanical equipment is put into operation, the system shall be tested in the presence of th 229 pdf_text
1.3 1.3. Has a longer side, parallel to the plane of the openings, at least 55 percent unobstructed from finished floor to underside of surface above. 123 pdf_text
1.4 1.4. The building is equipped throughout with an automatic sprinkler system in accordance w 59 pdf_text
1.4 1.4. Publicly-owned buildings. 110 pdf_text
1.5 1.5. Is separated from floor openings and air transfer openings serving other floors by constr conforming to required shaft enclosures. 60 pdf_text
1.6 1.6. Does not connect to a story containing a mezzanine. 60 pdf_text
10 10. Delete the following standards under ICC: ICC 500–14; ICC 600–14; IEBC–18; IECC–18; IFC–18; IFGC–18; 217 pdf_text
10 10. Revise the title and first sentence of Section 1704.5 to read: "1704.5 Documents made available to the building official. In addition to the reports of special inspections and tests in accordance with Section 1704.2.4, reports and certificates submitted to the owner and made available to the building official for each of the following:" 156 pdf_text
10 10. Revise Section 1507.8.9 by replacing "approved grading or inspection bureau or agency" with "approved agenc 137 pdf_text
10 10. Revise the definition of "aerosol product" to read: "AEROSOL PRODUCT. As defined in Chapter 2 of the Chicago Fire Prevention Code." 4 pdf_text
10 10. All panels shall be clearly labeled at the top to indicate the purpose or function, such as "detectio communication," "elevators," or "generator." 80 pdf_text
10 10,0 S1 UL UL 42 pdf_text
10 10. Replace each occurrence of "International Existing Building Code" with "Chicago Building Rehabilitation Cod 2 pdf_text
10 10 percent of units required to provide mobility features complying with Section 1107.5.1.1 or 1107.6.1.1 shall be us the minimum number of units required to provide accessible communication features complying with Section E104. 220 pdf_text
10 10. Revise Section 903.2.1.7 by replacing "shall be provided" with "shall be provided throughout the building." 68 pdf_text
10 10. Revise the exception to Section 2603.4.1.9 to read: "Exception: Garage doors using foam plastic insulation complying with Section 2603.3 in detached and attached pri associated with buildings of Group R-5 occupancy need not be provided with a thermal barrier." 192 pdf_text
10 10. Revise Section 1807.2.2 by replacing "Seismic Design Category D, E or F" with "Seismic Design Category D." 168 pdf_text
10 10. Delete the exceptions to Section 717.5.4. 62 pdf_text
10 10. Revise Section 907.2.3, including the exceptions, to read: "907.2.3 Group E. A manual fire alarm system shall be installed in Group E occupancies. Where automatic sprinkler systems or smoke installed, such systems or detectors shall be connected to the building fire alarm system." 74 pdf_text
10 10. Revise Section 2304.11.4 to replace "approved hardware" with "other approved hardware." 184 pdf_text
10 10. Revise Section D102.2.8 to read: "D102.2.8 Permanent canopies. Permanent canopies are permitted to extend over adjacent open spaces provided that all of the following are met: 218 pdf_text
10 10. Delete Section 2702.2.12. 196 pdf_text
10 10. Delete Figure 1808.7.1. 169 pdf_text
10 10. Revise Section 1404.7 to read: "1404.7 Anchored stone veneer. Anchored stone veneer units not exceeding 10 inches (254 mm) in thickness shall be anchored directly to masonry, c metal stud construction by corrosion-resistant clips or anchors located in the edge or back of the units. Veneer ancho capable of resisting a force equal to two times the weight of the attached veneer in tension and compression." 129 pdf_text
10 10. Revise Section 705.8.1 by replacing "Table 705.8" with "Table 705.8(1) or 705.8(2), as applicable" and insertin and 4 to read: "3. Where fire separation distance is based on an imaginary line between buildings on the same lot, the max protected exterior wall openings shall be the greater of the value in Table 705.8(1) or 10 percent for stories th 56 pdf_text
10 10. Revise row 27 of Table 1607.1 by adding an entry for "Shops" with a uniform value of "100" and concentrated "2,000." 147 pdf_text
10 10. An occupiable rooftop provided all the following criteria are met: 90 pdf_text
10 10,000 N H-4 NS c, d UL UL 42 pdf_text
10 10. Revise Section 1609.4.2 by deleting the second sentence describing Surface Roughness D. 149 pdf_text
10 10. Revise Section 406.5.3 to read: "406.5.3 Mixed occupancies and uses. Mixed uses shall be allowed in the same building as an open parking garage subject to the provisions of Sections 40 30 pdf_text
10 10. Add a new Section 1810.3.2.5.1 to read: 170 pdf_text
10 10. Revise the title and first sentence of Section 403.3.2 to read: "403.3.2 Secondary water supply to required fire pumps. In buildings that are more than 300 feet (91.4 m) in building height, required fire pumps shall be supplied by connect fewer than two water mains located in different streets." 25 pdf_text
10 10. Sheds open on a long side not over 15 feet (4572 mm) high and 400 square feet (37.2 m2) in area 219 pdf_text
10 10. Revise Section 2308.4.2.3 by deleting "in an approved manner." 185 pdf_text
10 10. Revise Section 1107.6.1.1 to read: "1107.6.1.1 Accessible units. Accessible units shall be provided in accordance with Table 1107.6.1.1. On a multiple-building site, Each structure t more than 50 dwelling units or sleeping units shall be considered separately for determining the minimum number an Accessible units required. On a multiple-building site, all structures that individually contain 50 or fewer dwelling un units, shall be considered together to determine the minimum number and type of Accessible units required. Accessib be dispersed among the various classes of units." 113 pdf_text
10 10. Revise Section 1202.4.1 to read: "1202.4.1 Ventilation openings. Ventilation openings through foundation walls shall be provided. The openings shall be placed so as to provide cross the under-floor space. The net area of ventilation openings shall be in accordance with Section 1202.4.1.1 or 1202.4. 121 pdf_text
10 10. Revise Section 714.5.4 by replacing "an approved" with "a." 60 pdf_text
10 10. Revise Section 1510.8 by replacing "Sections 1510.8.1 through 1510.8.5, as applicable" with "Section 1510.8.1. 139 pdf_text
10 10. Delete exception 2 to Section 706.6. 57 pdf_text
10 10. Revise Section 905.4 to read: "905.4 Location of Class I standpipe hose connections. Class I standpipe hose connections shall be provided in all of the following locations: 72 pdf_text
10 10. Delete exception 1 (and its subparts) to Section 1029.7. 105 pdf_text
10 10. Revise Table 1004.5 by revising the entries under "Residential" to read: 85 pdf_text
10 10. Revise Section 1805.3.2 by replacing "approved" with "equivalent." 165 pdf_text
10 10 to less than 15 e, g Unprotected, Nonsprinklered (UP, NS) 55 pdf_text
10 10. Delete the exception to Section 506.3.2. 44 pdf_text
10 10. Delete Section 1010.1.4.4.1. 93 pdf_text
10 10. Utility and Miscellaneous (see Section 312): Group U." 19 pdf_text
10 10. Revise Section 2303.2.9 to read: "2303.2.9 Type I and II construction applications. 183 pdf_text
10 10,0 S13R UL UL 42 pdf_text
10 10. Revise item 1 in Section 307.1.1 to delete "Section 416 and." 20 pdf_text
10 10% Unprotected, Sprinklered (UP, S) i 55 pdf_text
10 10. Delete Section 420.10 and its subsections. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 14; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 6)) 34 pdf_text
10 10. Revise the exception to Section 1011.7.3 by replacing "Group R-2 or R-3" with "Group R-2, R-3 or R-5." 97 pdf_text
10 10. Revise Section 308.5.4 to read: "308.5.4 Five or fewer individuals receiving care in a dwelling unit. A facility such as the above within a dwelling unit and having five or fewer individuals receiving custodial care shall as a Group R-2, R-3 or R-5 occupancy." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 4) 21 pdf_text
10 10. Delete Section 1406.11.4 and its subsections. 132 pdf_text
10 10,000 N SM UL 42 pdf_text
10 10. Add a new Section 1006.2.2.7 to read: "1006.2.2.7 Electrical rooms. Two exit access doorways are required in electrical rooms containing equipment rated 3,000 amperes or greater. Exit doorways shall be separated by a horizontal distance equal to not less than one-half the length of the maximum overa dimension of the room." 89 pdf_text
10 10. Revise items 1 and 2 in Section 1803.5.9 to read: "1. Recommended specifications for the preparation of the site prior to placement of the CLSM. 164 pdf_text
10 10. A telephone for fire department use. 80 pdf_text
10.1 10.1. Delete the entire section for MHI. 217 pdf_text
10.1 10.1. The occupiable rooftop is adjacent to a public way. 90 pdf_text
10.2 10.2. The occupiable rooftop is located no more than 12 feet (3658 mm) above the level of th 90 pdf_text
10.3 10.3. The net floor area does not exceed 800 square feet (74.3 m2). 90 pdf_text
100 100 sq. in. D-H-W-240 Not Permitted 61 pdf_text
100 100 sq. in. b < 100 sq. in. = D- H-90 >100 sq. in.= D- H-W-90 Not Permitted 61 pdf_text
100 100 sq. in. b, c < 100 sq. in. = D- H-90 > 100 sq. in.= D- H-T-W-90 Not Permitted 61 pdf_text
100 100. Revise the definition of "flammable liquefied gas" to read: "FLAMMABLE LIQUEFIED GAS. As defined in Chapter 2 of the Chicago Fire Prevention Code." 9 pdf_text
100 100 sq. in. D-H-W180 Not Permitted 61 pdf_text
1004 1004 to use an occupant load factor more intensive that 125 gross, the maximum occupant load is 49. i. Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.2. See Section 903 for occupancies where auto systems are permitted in accordance with Section 903.3.1.2. 88 pdf_text
1004.10.1 1004.10.1 and the cumulative occupant load for the occupancy shall be determined in accordance with Section 1004. 86 pdf_text
1004.10.1 1004.10.1 Occupant load for egress from the room or area. Means of egress directly from a room or area used in full for assembly-type functions shall be designed for th load determined in accordance with Section 1004.3 and Sections 1004.5 through 1004.8. 86 pdf_text
1004.10.2 1004.10.2 Cumulative occupant load. The cumulative occupant load for the Group B, F or M occupancy shall be determined in accordance with Se 86 pdf_text
1004.10.2.1 1004.10.2.1 Rooms up to 150 square feet. For individual rooms or spaces with a gross floor area of 150 square feet (13.9 m 2 ) or less, the occu be determined by applying the occupant load factor in Table 1004.5 that is applicable to the predomin adjacent spaces within the same suite and same story which are not used for assembly-type functions. 86 pdf_text
1004.10.2.2 1004.10.2.2 Rooms up to 750 square feet. For individual rooms or spaces with a gross floor area greater than 150 square feet (13.9 m 2 ) but not 87 pdf_text
1004.10.2.3 1004.10.2.3 Non-public meeting and training rooms. For rooms and spaces used with tables and chairs for meetings, conferences and training primarily att individuals employed in the same building and not open to the general public, the occupant load shall by applying the occupant load factor for "classroom areas" in Table 1004.5." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 40; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 20; Amend Coun. J. 6-25-21, II, § 15; Amend Coun. J. 1-24-24, p. 8634, Art. IV, § 2) 87 pdf_text
101 101. Revise the definition of "flammable liquid" to read: "FLAMMABLE LIQUID. As defined in Chapter 2 of the Chicago Fire Prevention Code." 9 pdf_text
101.1 101.1 Title. This Title 14B of the Municipal Code of Chicago shall be known as the Chicago Building Code, hereinafter referred code." 2 pdf_text
101.3 101.3 Intent. The purpose of this code is to establish the minimum requirements to provide a reasonable level of safety, public hea welfare through structural strength, means of egress facilities, stability, sanitation, adequate light and ventilation, ene conservation, and safety to life and property from fire, explosion and other hazards, and to provide a reasonable level fire fighters and emergency responders during emergency operations." CHAPTER 14B-2 DEFINITIONS AND MEASUREMENTS 3 pdf_text
1010.2.2.1 1010.2.2.1 Small residential buildings. On a lot containing buildings with not more than 4 stories above grade plane and not more than 4 dwelling u units, an exterior gate is allowed to require a key or special tool to operate in either or both directions. 95 pdf_text
1010.2.2.2 1010.2.2.2 Large residential buildings. On a lot containing buildings with 5 or more stories above grade plane or containing 5 or more dwelling unit units, an exterior gate shall not require a key or special tool to operate in the direction of egress." 95 pdf_text
1011.4.1 1011.4.1 Other than Group R-5 occupancies and within dwelling units. The walkline across winder treads in other than R-5 occupancies and within individual dwelling units in Grou 95 pdf_text
1011.4.2 1011.4.2 Group R-5 occupancies and within dwelling units. The walkline across winder treads in R-5 occupancies and within individual dwelling units in Group R-2 occu be concentric to the direction of travel through the turn and located 18 inches (457 mm) from the side where t narrower." 96 pdf_text
1013.6.1 1013.6.1 Graphics. Every exit sign and directional exit sign shall have plainly legible letters not less than 3 3/8 inches (86 mm) h principal strokes of the letters not less than 9/16 inch (14 mm) wide. Directional exit signs shall have a horizo 98 pdf_text
1013.6.1.1 1013.6.1.1 Exit sign. Exit signs, other than those subject to Section 1013.6.1.2 or 1013.6.1.3 shall read "EXIT." 99 pdf_text
1013.6.1.2 1013.6.1.2 Stair sign. Exit signs located immediately over an exit access stairway or exit access door leading to an exit stair "STAIR" or "EXIT STAIR." In existing buildings, new exit signs may also read "STAIRS" or "STAI consistent with existing exit signs. 99 pdf_text
1013.6.1.3 1013.6.1.3 Fire escape sign. In existing buildings, exit signs and directional exit signs leading to a fire escape shall read "FIRE ES 99 pdf_text
1013.6.2 1013.6.2 Exit sign illumination. The face of an exit sign shall be illuminated to meet the luminance measurement test in UL 924. 99 pdf_text
1013.6.3 1013.6.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 case of primary power loss, the sign illumination means shall be connected to an emergency power system pr storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shal accordance with Article 700 of the Chicago Electrical Code." 99 pdf_text
102 102. Revise the definition of "flammable material" to read: "FLAMMABLE MATERIAL. As defined in Chapter 2 of the Chicago Fire Prevention Code." 9 pdf_text
1027.2.1 1027.2.1 Limitation. Not more than 50 percent of the number and minimum width or required capacity of means of egress compon provided using exterior exit stairways or exterior exit ramps. Exceptions: 103 pdf_text
103 103. Revise the definition of "flammable solid" to read: "FLAMMABLE SOLID. As defined in Chapter 2 of the Chicago Fire Prevention Code." 9 pdf_text
1031.1 1031.1 Frontage requirement. The portion of a building containing a Group E-1 occupancy shall abut the number and type of public ways or yards Table 1031.1. For purposes of this section, each side shall be at least 12 percent of the perimeter of the occupancy. T required public ways and yards shall be measured as provided in Section 506.3. TABLE 1031.1 FRONTAGE REQUIREMENTS For SI: 1 foot = 304.8 mm. 106 pdf_text
1031.2 1031.2 Fire department access panels. Where the exterior wall on any story of a Group E-1 occupancy exceeds 100 linear feet (30.5 m) without windows, d similar openings, fire department access panels shall be provided at intervals not exceeding 50 feet (15.2 m). Exception: Exterior walls of auditoriums, assembly halls, field houses, gymnasiums, swimming pools, and t 106 pdf_text
1031.2.1 1031.2.1 Dimensions. Fire department access panels shall be not less than 32 inches (812.8 mm) wide and 48 inches (1219.2 mm) h department access panels shall be located not more than 32 inches (812.8 mm) above the floor. 106 pdf_text
1031.2.2 1031.2.2 Construction. Fire department access panels shall be approved by the fire code official and constructed of materials and inst manner to be readily removed by the fire department. (Added Coun. J. 10-7-20, p. 21791, Art. II, § 25) CHAPTER 14B-11 ACCESSIBILITY 106 pdf_text
104 104. Revise the definition of "flammable vapors or fumes" to read: "FLAMMABLE VAPORS OR FUMES. As defined in Chapter 2 of the Chicago Fire Prevention Code." 9 pdf_text
105 105. Revise the definition of "flash point" to read: "FLASH POINT. As defined in Chapter 2 of the Chicago Fire Prevention Code." 9 pdf_text
106 106. Delete the definition of "flood damage-resistant materials." 9 pdf_text
107 107. Delete the definition of "flood, design." 9 pdf_text
108 108. Delete the definition of "flood elevation, design." 9 pdf_text
109 109. Delete the definition of "flood hazard area." 9 pdf_text
11 11 where the risers and treads comply with Section 1011.5, the minimum depth of the tread is 13 inches (330 handrail is provided in accordance with Section 1014." 85 pdf_text
11 11. Insert the following definition: "AFFORDABLE UNIT (for Chapter 11). A dwelling unit or sleeping unit required to be affordable, as that term is Chapter 2-44 of the Municipal Code, pursuant to Chapter 2-44 of the Municipal Code, an agreement between the ow City, or an agreement between the owner and another governmental entity." 4 pdf_text
11 11. Revise Section 1807.2.3 by replacing "1.5 in each case" with "1.5 and 2.0 respectively." 168 pdf_text
11 11. An occupiable rooftop provided both of the following criteria are met: 90 pdf_text
11 11. Revise item 17 in Section 307.1.1 to delete "Section 428 and Chapter 38 of." 20 pdf_text
11 11. Delete Section 1202.4.2. 121 pdf_text
11 11. Revise Section 705.8.3 by replacing "approved materials" with "materials allowed by this code." 56 pdf_text
11 11. Revise Section 1011.8 to read: "1011.8 Vertical rise. A flight of stairs shall not have a vertical rise greater than 12 feet (3658 mm) between floor levels or landings. Exceptions: 97 pdf_text
11 11. Revise Section 1006.3 to read: "1006.3 Egress from stories or occupiable rooftops. The means of egress system serving any story or occupiable rooftop shall be provided with the number of separate a or access to exits based on the aggregate occupant load served in accordance with this section. Where stairways serv one story or occupiable rooftop, only the occupant load of each story or occupiable rooftop considered individually s calculating the required number of exits or access to exits serving that story or occupiable rooftop." 89 pdf_text
11 11. Revise Exception 3 to Section 706.6 by replacing "Class B roof covering" with "Class A roof covering." 57 pdf_text
11 11. Revise Table 1808.8.1 by replacing "Seismic Design Category D, E or F" with "Seismic Design Category D." 169 pdf_text
11 11. Revise Table 1810.3.2.6, excluding the notes, as follows: MATERIAL TYPE AND CONDITION MAXIMUM ALLOWABLE ST MATERIAL TYPE AND CONDITION MAXIMUM ALLOWABLE ST 171 pdf_text
11 11. Delete Sections 1510.8.2, 1510.8.3, 1510.8.4, and 1510.8.5. 139 pdf_text
11 11. Delete Section 2603.4.1.12. 192 pdf_text
11 11. Revise Section 2304.11.4.1 to read: "2304.11.4.1 Cross-laminated timber roofs. Where approved for use, cross-laminated timber roofs shall comply with this section. Cross-laminated timber roofs less than 3 inches (76 mm) in actual thickness, and shall be continuous from support to support. Individual panels sh mechanically fastened to one another." 184 pdf_text
11 11. Revise note a to Table 1004.5 to read: "a. Net floor area or gross floor area in square feet per occupant." 86 pdf_text
11 11. Revise Section 903.2.2 to read: "903.2.2 Group B. An automatic sprinkler system shall be provided for Group B occupancies as provided in this section. 68 pdf_text
11 11. Revise Section 1507.9.10 by replacing "approved grading or inspection bureau or agency" with "approved agen 137 pdf_text
11 11. Revise Section D102.2.9 to read: "D102.2.9 Rooftop structures. Rooftop structures, except aerial supports 12 feet (3658 mm) high or less shall be of noncombustible material and sh by construction of noncombustible material." 218 pdf_text
11 11. Revise Section 2702.2.13 by replacing "90 minutes" with "required by the Chicago Electrical Code." 196 pdf_text
11 11. Revise Section 714.6.1 by replacing "an approved" with "a." 60 pdf_text
11 11. Revise exception 1 to Section 1010.1.5, exclusive of subparts, to read: "1. Doors serving individual dwelling units in Groups R-2, R-3 and R-5 occupancies where the following ap 93 pdf_text
11 11. Revise Section 1704.5, item 7, by replacing "Seismic Design Category B, C, D, E or F" with "Seismic Design C D." 156 pdf_text
11 11. Revise Equation 5-5 to read: "If = (F/P)(W/30)(S) (Equation 5-5) where: If = Area factor increase due to frontage. F = Building perimeter that fronts on a public way or yard having a minimum width of 20 feet (609 P = Perimeter of entire building (feet). W = Width of public way or yard (feet) in accordance with Section 506.3.2. S = Where building is equipped throughout with an automatic sprinkler system in ac 44 pdf_text
11 11. Revise Section 1705.6, excluding the exception, to read: "1705.6 Soils. Special inspections and tests of existing site soil conditions, fill placement and load-bearing requirements shall be pe accordance with this section and Table 1705.6. The geotechnical report prepared by the registered geotechnical engi permitted construction documents shall be used to determine compliance. During fill placement, the special inspecto that proper materials and procedures are used in accordance with the provisions of the geotechnical report." 158 pdf_text
11 11. Revise the title of Table 1107.6.1.1 to "ACCESSIBLE UNITS." 113 pdf_text
11 11. Delete Section 717.5.4.1. 62 pdf_text
11 11. Revise Section 1805.3.3 by replacing "approved" with "equivalent." 165 pdf_text
11 11. Delete Section 1803.5.10. 164 pdf_text
11 11. Revise the first sentence of Section 2303.4.1.1 to read: "The written, graphic and pictorial depiction of each individual truss shall be provided to the registered design profes responsible charge for approval prior to installation." 184 pdf_text
11 11. Revise exception 2 to Section 1029.8 by deleting "smoke-protected or." 105 pdf_text
11 11. Delete the following standards under NFPA: 4–18; 70–17; and 221–18. 217 pdf_text
11 11. Delete Section 1404.8. 129 pdf_text
11 11. Replace each occurrence of "International Property Maintenance Code" with "Chicago Minimum Requirements Buildings." 2 pdf_text
11 11. Delete Sections 406.5.4 and 406.5.4.1 and Table 406.5.4 30 pdf_text
11 11. Revise the title and first sentence of Section 403.3.3 to read: "403.3.3 Secondary on-site water supply. An automatic secondary on-site water supply having a capacity not less than the hydraulically calculated sprinkler de including the hose stream requirement, shall be provided for high-rise buildings assigned to Seismic Design Categor determined by Section 1613." 25 pdf_text
11 11. Insert a new Section 1609.6 to read: "1609.6 Alternative wind loads for enclosed structure with mean roof height of 60 feet or less. Where the mean roof height of a structure is 60 feet (18.3 m) or less, wind loads on the main windforce-resisting sys components and cladding shall be permitted to be determined in accordance with Section 1609.6, provided the follo are met: 149 pdf_text
11 11. Revise row 30 of Table 1607.1 by replacing "One- and two-family" with "Group R-5 (interior)." 147 pdf_text
11 11. Revise Section 2308.4.4.1 to read: "2308.4.4.1 Openings in floor diaphragms in Seismic Design Category B or C. Openings in horizontal diaphragms in Seismic Design Category B or C with a dimension that is greater than 4 feet (1 be constructed with metal ties and blocking in accordance with this section and Figure 2308.4.4.1(1). Metal ties shall than 0.058 inch [1.47 mm (16 galvanized gage)] in thickness by 1 1/2 inches (38 mm) in width and shall have a yield than 33,000 psi (227 Mpa). Blocking shall extend not less than the dimension of the opening in the direction of the ti blocking. Ties shall be attached to blocking in accordance with the manufacturer's instructions but with not less than common nails on each side of the header-joist intersection." 185 pdf_text
11 11. Fire pump status indicators. 80 pdf_text
11 11. Revise the exception to Section 905.4.1 to delete "approved." 73 pdf_text
11 11. Revise the exception to Section 907.2.4 to read: "Exception: Manual fire alarm boxes are not required where the building is equipped throughout with an automatic system installed in accordance with Section 903.3.1.1 and the occupant notification appliances will activate in accord 74 pdf_text
11.1 11.1. Add a new Section 403.3.5 to read: "403.3.5 Standpipe system. Where building height exceeds 500 feet (152.4 m), the connection to the source of supply shall be located in the low building, and the piping system shall be completely looped, without dead ends." 25 pdf_text
11.1 11.1. The occupiable rooftop is located no more than 40 feet (12.2 m) above grade plane. 90 pdf_text
11.2 11.2. The net floor area does not exceed 300 square feet (27.9 m2). 90 pdf_text
110 110. Delete the definition of "flood hazard areas, special." 9 pdf_text
1101.1 1101.1 Scope. The provisions of this chapter and Appendix E shall control the design and construction of facilities for accessibility with disabilities. 107 pdf_text
1101.2 1101.2 Rulemaking. The Commissioner of the Mayor’s Office for People with Disabilities and the building official may jointly promulgat necessary to implement the requirements of this chapter. Rules promulgated under this section shall comply with the and comment procedures in Section 104.4 of the Chicago Construction Codes Administrative Provisions and be post City’s public website. 107 pdf_text
1101.2.1 1101.2.1 Illinois Accessibility Code. The Commissioner of the Mayor’s Office for People with Disabilities may promulgate rules to enforce a spec of the Illinois Accessibility Code if the Commissioner determines that the provision requires a greater degree usability for individuals with disabilities than the corresponding provision of this code. 107 pdf_text
1101.2.2 1101.2.2 Projects owned or financed by a governmental unit. The Commissioner of the Mayor’s Office for People with Disabilities and the Commissioner of Housing may promulgate rules for housing that is owned or financed by a governmental unit. Such rules may require a grea access and usability for individuals with disabilities than is provided for in this chapter. 107 pdf_text
1101.3 1101.3 Notice and warning. While efforts have been made to coordinate the accessibility requirements of this code with similar laws, this code h certified by the federal government or State of Illinois as a safe-harbor under the Americans with Disabilities Act (" Rehabilitation Act, the Fair Housing Act or any State of Illinois accessibility laws, including but not limited to the E Barriers Act, and may not conform in all respects with those laws. Therefore, compliance with this code does not ass with the ADA, the Rehabilitation Act, the Fair Housing Act or any other federal or state laws, or any rules promulgat respect to such laws. The City of Chicago is not responsible for enforcement of the ADA, Rehabilitation Act, Fair H such other federal or state laws, except as specifically provided in this code. Permit applications submitted under this reviewed and permitted work will be inspected for compliance with the Chicago Construction Codes and will not be compliance with the requirements of the ADA, Rehabilitation Act, Fair Housing Act or other federal or state laws, e specifically provided in this code. Therefore, it is the responsibility of the developer or owner to have plans or faciliti independently evaluated by knowledgeable professionals in order to meet or exceed the applicable requirements of a federal and state accessibility laws. Similarly, compliance with federal and state laws does not establish compliance Exception: Where work is done by, on behalf of or with 107 pdf_text
1101.3 (cont. 2) financial assistance provided by the City, the Comm Mayor’s Office for People with Disabilities shall prescribe procedures to ensure the work complies with the obligations under federal and state law and Section 1101.2.2. 107 pdf_text
1101.4 1101.4 Modifications to ICC A117.1. The text of ICC A117.1 shall be modified as indicated in Sections 1101.4.1 through 1101.4.8. 107 pdf_text
1101.4.1 1101.4.1 ICC A117.1 Section 302.1. Modify Section 302.1 by adding exceptions to read as follows: "1. Animal containment areas shall not be required to comply with this section or with Sectio 107 pdf_text
1101.4.10 1101.4.10 IAC A117.1 Section 804.5.2. Modify Section 804.5.2 by adding a new Exception 3 to read as follows: "3. Filters in dishwashers and refrigerators and other parts or controls used only for periodic appliances shall not be required to comply with Section 309." 109 pdf_text
1101.4.11 1101.4.11 ICC A117.1 Section 1003.11.2. Modify Section 1003.11.2 by adding a new Section 1003.11.2.6 to read as follows: "1003.11.2.6 Toilet Paper Dispenser. Toilet paper dispensers shall comply with Section 604.7." 109 pdf_text
1101.4.12 1101.4.12 ICC A117.1 Sections 1002.14 and 1003.14. Modify Sections 1002.14 and 1003.14 by revising the exception to each section to read as follows: "EXCEPTIONS: 109 pdf_text
1101.4.13 1101.4.13 ICC A117.1 Section 1005.4. Modify Section 1005.4, including the exception, to read as follows: "1005.4 Interior Spaces. The entrance level shall include a toilet room or bathroom complying with one food preparation area complying with Section 1005.7, and a habitable space, other than the food p area, with a floor area at least 70 square feet (6.5 m2)." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 54; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 12) 109 pdf_text
1101.4.2 1101.4.2 ICC A117.1 Section 404.2.8. Modify Section 404.2.8 by adding Item 3 to read as follows: "3. Exterior hinged doors and gates: 8.5 pounds (37.8N) maximum" 107 pdf_text
1101.4.3 1101.4.3 ICC A117.1 Section 502. Modify Section 502 by replacing it in its entirety with Section 502 of the Illinois Accessibility Code. 108 pdf_text
1101.4.4 1101.4.4 ICC A117.1 Section 604.3. Modify Section 604.3 by adding a new Section 604.3.4 to read as follows: "604.3.4 Changes in Level. Floor or ground surfaces within the required clearance shall comply with Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted." 108 pdf_text
1101.4.5 1101.4.5 ICC A117.1 Section 607.2. Modify Section 607.2 by adding the following sentence and exception at the end: "Floor or ground surfaces within the required clearance shall comply with Section 302. Changes in le permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted." 108 pdf_text
1101.4.6 1101.4.6 ICC A117.1 Section 607.6. Modify Section 607.6 to read: "A hand shower with a hose 59 inches (1500 mm) minimum in length that can be used as both a fixed shower hand shower shall be provided. The shower spray unit shall be located within one or more of the reach ranges 108 pdf_text
1101.4.7 1101.4.7 ICC A117.1 Section 608.2. Modify Section 608.2 by adding the following sentence and exception at the end: "Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted." 108 pdf_text
1101.4.8 1101.4.8 ICC A117.1 Section 802. Modify Section 802.1 to read as follows: "802.1 General. Wheelchair spaces and wheelchair space locations in assembly areas with spe shall comply with Section 802. Where tiered seating includes dining surfaces or work surfaces spaces and wheelchair space locations shall comply with Section 802.6. 802.7, 802.9, 802.10 a and player seating shall comply with Sections 802.2 through 802.7." Modify Section 802.7.2 to read as follows: "802.7.2 Companion Seat Alignment. In row seating, the companion seat shall be located to shoulder alignment with the wheelchair space occupant. The shoulder of the wheelchair space considered to be 36 inches (915 mm) or more from the front and 12 inches (305 mm) or more of the wheelchair space. The floor surface for the companion seat shall be at the same elevatio wheelchair space floor surface. EXCEPTION: Companion seat alignment shall not be required in tiered seating that i surfaces or work surfaces." Modify Section 802.8.2 to read as follows: "802.8.2 Identification. Each designated aisle seat shall be identified by a sign or marker." Modify Section 802.10.1, excluding its exception, to read as follows: "802.10.1 Horizontal Dispersion. Wheelchair space locations shall be dispersed horizontally viewing options. Where seating encircles the stage or field, in whole or in part, horizontal disp include the entire seating area. Two wheelchair spaces shall be permitted to be located side-by Modify Section 802.10.4.1 t 108 pdf_text
1101.4.8 (cont. 2) o read as follows: "802.10.4.1 Spaces with Seating on Risers. Where tiered seating is provided, wheelchair spa shall be integrated into the tiered seating area on a riser or a cross-aisle." Modify Section 802.10.4.2 to read as follows: "802.10.4.2 Distance from the Screen. Wheelchair space locations shall be located in accord of the following: 108 pdf_text
1101.4.9 1101.4.9 ICC A117.1 Section 803. Modify Section 803 by adding a new Section 803.6 to read as follows: "803.6 Mirrors. Mirrors provided within the room shall be installed with the bottom edge of the refle 109 pdf_text
1107.5.5.1 1107.5.5.1 through 1107.5.5.3 and Appendix E." 113 pdf_text
1107.6.2.1 1107.6.2.1 Live/work units. In live/work units constructed in accordance with Section 419, the nonresidential portion is required to be acc multi-story housing, the residential portions of at least 20 percent of the live/work units shall be Type A units. where there are four or more live/work units, the residential portions of the live/work units shall be Type B uni Exception: The number of Type B units is permitted to be reduced in accordance with Section 1107.7 114 pdf_text
1107.6.2.2 1107.6.2.2 Apartment houses and congregate living facilities. Type A units and Type B units shall be provided in apartment houses and congregate living facilities, other th place of education required to comply with Section 1107.6.2.3, in accordance with Sections 1107.6.2.2.1 and Bedrooms in congregate living facilities shall be counted as sleeping units for the purpose of determining the units. Where the bedrooms are grouped into dwelling units or sleeping units, only one bedroom in each dwelli sleeping unit shall count toward the number of required Type A units. Exception: Where the number of required Type A units exceeds the number of dwelling units and sle at least one bedroom in each dwelling unit and sleeping unit is a Type A unit, more than one bedroom dwelling unit and sleeping unit may count toward the number of required Type A units. 114 pdf_text
1107.6.2.2.1 1107.6.2.2.1 Type A units. 114 pdf_text
1107.6.2.2.1.1 1107.6.2.2.1.1 Multi-story housing In multi-story housing, at least 20 percent of the dwelling units and sleeping units shall be Typ 114 pdf_text
1107.6.2.2.1.2 1107.6.2.2.1.2 Other than multi-story housing. In buildings three stories or less in height containing more than 20 dwelling units or sleeping u percent but not less than one of the units shall be a Type A unit. Exceptions: 114 pdf_text
1107.6.2.2.1.3 1107.6.2.2.1.3 Dispersion. Type A units shall be distributed proportionally throughout the building to provide a variety of locations and of affordable units and market rate units. 114 pdf_text
1107.6.2.2.2 1107.6.2.2.2 Type B units. Where there are four or more dwelling units or sleeping units in a single structure, every dwelling unit unit shall be a Type B unit. Exception: The number of Type B units is permitted to be reduced in accordance with Section 114 pdf_text
1107.6.2.3 1107.6.2.3 Housing at a place of education. In housing at a place of education, Accessible units and Type B units shall be provided in accordance with Se 114 pdf_text
1107.6.2.3.1 1107.6.2.3.1 and 1107.6.2.3.2. Bedrooms within congregate living facilities shall be counted as sleeping units purpose of determining the number of units. Where the bedrooms are grouped into dwelling units or sleeping bedroom in each dwelling unit or sleeping unit shall be permitted to count toward the number of required Acc Exceptions: 114 pdf_text
1107.6.2.3.1 1107.6.2.3.1 Accessible units and units with communication features. Accessible units and units with communication features shall be provided in accordance with Section Appendix E. 115 pdf_text
1107.6.2.3.2 1107.6.2.3.2 Type B units. Where there are four or more dwelling units or sleeping units in a single structure, every dwelling unit sleeping unit shall be a Type B unit. Exception: The number of Type B units is permitted to be reduced in accordance with Section 115 pdf_text
1107.7.7 1107.7.7 Multistory Type A units with provision for future elevator. A multistory unit required to be a Type A unit may be constructed so that an accessible route to levels above or belo level can be provided by the owner by the installation of a limited-use/limited application elevator, private residence platform lift when appropriate. Provisions for the future elevator or platform lift shall comply with Section 1107.8.3. 115 pdf_text
1107.8.1 1107.8.1 Construction documents. The following information shall be included in the construction documents: 116 pdf_text
1107.8.2 1107.8.2 Type A units. At least 10 percent of units, but not less than one, in a planned development shall be Type A units. The required Type be distributed proportionally among the various types and classes of units provided in the planned development. Exceptions: 116 pdf_text
1107.8.3 1107.8.3 Attached multistory units with separate means of egress. Attached multistory units with separate means of egress required to be Type A units may be designed and constructed units or in accordance with Section 1107.8.3.1. 116 pdf_text
1107.8.3.1 1107.8.3.1 Multistory unit standard. Units shall be constructed as Type C units and shall comply with Sections 1107.8.3.1.1 through 1107.8.3.1.3. 116 pdf_text
1107.8.3.1.1 1107.8.3.1.1 Toilet and bathing facility. All toilet and bathing facilities shall comply with the requirements for toilet and bathing facilities in T however toilet and bathing facilities other than those required for Type C units shall be allowed to be l levels not initially provided with vertical access. This provision is not intended to require more than o bathing facility within a unit. 116 pdf_text
1107.8.3.1.2 1107.8.3.1.2 Kitchen. At least one kitchen complying with the kitchen requirements for a Type A unit shall be provided, how kitchen shall be allowed to be located on a level not initially provided with vertical access. 116 pdf_text
1107.8.3.1.3 1107.8.3.1.3 Provision for vertical access. Provisions for future access within the unit to all levels above and below the entrance level shall be p of the following methods: 116 pdf_text
1107.8.4 1107.8.4 Type B units. Where there are four or more dwelling units or sleeping units in a single structure, every dwelling unit and every slee be a Type B unit. Exception: The number of Type B units is permitted to be reduced in accordance with Section 1107.7. 117 pdf_text
1107.8.5 1107.8.5 Type C (visitable) units. Type C units shall be provided in accordance with Section 1107.8.5.1 or 1107.8.5.2. 117 pdf_text
1107.8.5.1 1107.8.5.1 Multi-unit buildings. At least 10 percent of units, but not less than one, in multi-unit buildings in planned developments shall be Ty Units provided to satisfy Section 1107.8.2 or 1107.8.3 shall not be counted toward the number of Type C unit this section. Exception: In a building in which the minimum number of required Type A units has been provided, t Type C units is not required to exceed the remaining number of units, if any, on the levels that contain 117 pdf_text
1107.8.5.2 1107.8.5.2 Detached single-family dwellings. At least 20 percent, but not less than one, of all detached single-family dwellings in a planned development s units. 117 pdf_text
1107.8.6 1107.8.6 Units with visible alarm notification appliances. In buildings required to have a fire alarm system of a type that sends an alarm signal to occupants of more than just a dwelling unit or sleeping unit, not less than 20 percent of the dwelling units and sleeping units shall be provided with notification appliances or provided with connections to allow the future installation of visible alarm notification appl dwelling units and sleeping units shall be distributed proportionally among the various types and classes of units pro 117 pdf_text
1107.9.1 1107.9.1 Type A units. At least 20 percent of affordable units, but not less than one, shall be Type A units. The required Type A units distributed proportionally among the various types and classes of units provided in the development. 117 pdf_text
1107.9.1 1107.9.1 shall not be counted toward the number of Type C units required by this section. 117 pdf_text
1107.9.2 1107.9.2 Type B units. Where there are four or more dwelling units or sleeping units in a single structure, every affordable unit shall unit. Exception: The number of Type B units is permitted to be reduced in accordance with Section 1107.7 117 pdf_text
1107.9.3 1107.9.3 Type C (visitable) units. At least 10 percent of affordable units, but not less than one, shall be Type C units. Type A units provided to s 117 pdf_text
1107.9.4 1107.9.4 Units with visible alarm notification appliances. In buildings required to have a fire alarm system of a type that sends an alarm signal to occupants of more tha individual dwelling unit or sleeping unit, not less than 20 percent of the affordable units shall be provided wit notification appliances or provided with connections to allow the future installation of visible alarm notificati These units shall be distributed proportionally among the various types and classes of affordable units provid (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 55; Amend Coun. J. 6-25-21, p. 32180, Art. II, § 20; Amend Coun. J. 9-14-21, XV, § 9) 118 pdf_text
1109.12.1.2 1109.12.1.2 Mirrors. Where mirrors are provided in dressing rooms of the same use, then at least one accessible mirror shall be provided i accessible dressing room." 119 pdf_text
111 111. Delete the definition of "flood insurance rate map (FIRM)." 9 pdf_text
112 112. Delete the definition of "flood insurance study." 9 pdf_text
113 113. Delete the definition of "floodway." 9 pdf_text
114 114. Revise the definition of "floor area, gross" to read: "FLOOR AREA, GROSS. The value determined in accordance with section 203.5.1." 9 pdf_text
115 115. Revise the definition of "floor area, net" to read: "FLOOR AREA, NET. The value determined in accordance with section 203.5.2." 9 pdf_text
116 116. Delete the definition of "food court." 9 pdf_text
117 117. Revise the definition of "foster care facilities" to read: 9 pdf_text
118 118. Revise the definition of "gas cabinet" to read: "GAS CABINET. As defined in Chapter 2 of the Chicago Fire Prevention Code." 10 pdf_text
119 119. Revise the definition of "gaseous hydrogen system" to read: "GASEOUS HYDROGEN SYSTEM. As defined in Chapter 2 of the Chicago Fire Prevention Code." 10 pdf_text
12 12. Revise Section 2603.4.1.14 by replacing "approved" with "approved." 192 pdf_text
12 12. The minimum clear opening width shall not apply to the doors for toilet stalls or single-user toilet rooms to be accessible." 93 pdf_text
12 12. Site class in accordance with Chapter 20 of ASCE 7 and the horizontal seismic forces to be considered i stability analysis." 164 pdf_text
12 12. Revise Section 905.5.3 by replacing "approved" with "permitted." 73 pdf_text
12 12. Add a new Section 11107.6.1.1.1 to read: "1107.6.1.1.1 Beds. In sleeping units having more than 25 beds, at least 5 percent of the beds shall be accessible." 113 pdf_text
12 12. Delete Section 2303.4.1.4 and its subsections. 184 pdf_text
12 12,0 SM UL 42 pdf_text
12 12. Revise Section 903.2.3 to read: "903.2.3 Group E. An automatic sprinkler system shall be provided for Group E occupancies as follows: 68 pdf_text
12 12. Revise exception 3 to Section 1010.1.5 to read: "3. In Group R-2, R-3 and R-5 occupancies not required to be Accessible units, Type A units or Type B units, an exterior doorway shall be not more than 8 inches (203 mm) below the top of the threshold, provided the d an exterior storm or screen door, does not swing over the landing." 93 pdf_text
12 12. Revise Section 2702.2.14 by deleting the last sentence. 196 pdf_text
12 12. Revise Section 1507.11 and its subsections by replacing each instance of "modified bitumen roofing" with "mod roof covering." 137 pdf_text
12 12. Revise Section 1805.4 to read: "1805.4 Subsoil drainage system. Where a permanent hydrostatic pressure condition does not exist, dampproofing shall be provided and a granular bas be installed under the floor and a drain installed around the foundation perimeter. A subsoil drainage system designe constructed in accordance with Section 1805.1.3 shall be deemed adequate for lowering the ground-water table." 165 pdf_text
12 12. A basement with a floor area that does not exceed 2,000 square feet (185.8 m2) that is used exclu storage or mechanical equipment, with only incidental human occupancy. 90 pdf_text
12 12. Revise Section 907.2.5 by deleting "Chapters 60, 62 and 62, respectively, of." 74 pdf_text
12 12. Delete Section 1202.4.4. 121 pdf_text
12 12. Delete each bracketed designation of ICC code development committee responsibility preceding a section numb 2 pdf_text
12 12. Revise row 31 of Table 1607.1 to read: 147 pdf_text
12 12. Delete exceptions 4 and 5 to Section 706.6. 58 pdf_text
12 12. Revise Section 1004.5.1 to read: "1004.5.1 Increased occupant load. Where approved by the building official, the occupant load permitted in any building, or portion thereof, may be incr that number established for the occupancies in Table 1004.5, provided that all other requirements of the code are met modified number and the occupant load does not exceed one occupant per 7 square feet (0.65 m2) of occupiable floor aisle, seating or fixed equipment diagram substantiating any increase in occupant load shall be submitted." 86 pdf_text
12 12. Revise Section 403.4.4 to read: "403.4.4 Voice communication systems. Voice communication systems shall be provided in accordance with Section 907.2.12.2." 25 pdf_text
12 12. Revise the title of Section D103 to: "CHANGES TO BUILDINGS AND STRUCTURES." 218 pdf_text
12 12. Revise Sections 2304.12.1.1, 2304.12.1.2, 2304.12.1.3, 2304.12.1.4 and 2304.12.1.5 to replace "naturally durab preservative-treated wood" with "naturally durable wood or preservative-treated wood." 184 pdf_text
12 12. Revise the title and first sentence of Section 1803.5.11 to read: "1803.5.11 Seismic Design Category C or D. For structures assigned to Seismic Design Category C or D a geotechnical investigation shall be conducted, and shall evaluation of all of the following potential geologic and seismic hazards:" 164 pdf_text
12 12. Revise exception 1 to Section 1006.3.1 by replacing "Group R-1, R-2 or R-2" with "Group R." 89 pdf_text
12 12. Revise Section 307.7 by replacing "Section 415.11" with "the Chicago Fire Prevention Code." 20 pdf_text
12 12. Revise Section 1704.6 and its subsections to read: "1704.6 Structural observations. Where required by the provisions of Section 1704.6.1 or 1704.6.2, the owner shall employ a registered design profes 156 pdf_text
12 12. Revise Section 1404.9 to read: "1404.9 Terra cotta. 129 pdf_text
12 12. Wood or other combustible veneers on exterior walls conforming to Section 1404.5, not extendi first story above grade plane. 219 pdf_text
12 12. Revise the exception to Section 1807.2.3 by adding a sentence at the end to read: "Earthquake loads shall not be required to be considered for the design of temporary earth retention systems during c (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 79) 168 pdf_text
12 12,0 SM UL UL 41 pdf_text
12 12. Revise the last sentence of Section 1810.3.2.8 to read: "The design and installation of the deep foundation elements shall be under the direct supervision of a registered geo engineer knowledgeable in the field of soil mechanics and deep foundations or their qualified representative who sha report to the owner stating that the elements as installed satisfy the design criteria. The report shall be made available building official." 171 pdf_text
12 12. Schematic building plans indicating the typical floor plan and detailing the building core, means protection systems, fire fighter air replenishment system, fire-fighting equipment and fire department location of fire walls, fire barriers, fire partitions, smoke barriers and smoke partitions. 80 pdf_text
12 12. Revise Section 714.6.2 by replacing "an approved" with "a." 60 pdf_text
12 12. Revise the definition of "alteration" to read: "ALTERATION. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 4 pdf_text
12 12. Revise the second sentence of Section 1705.7 to read: "The geotechnical report prepared by the registered geotechnical engineer and the permitted construction documents to determine compliance." 158 pdf_text
12 12. Revise row 4 of Table 1808.8.1 to read "4. Drilled shafts and auger cast piles." 169 pdf_text
12 12. Revise the exception to Section 1011.9 by replacing "Group R-3" with "Group R-3 and R 5." 97 pdf_text
12 12. Delete Section 2308.4.4.2 and its exception. 186 pdf_text
12 12. Revise the description of Ap in Equation 7-2 to read: "Actual area of protected openings." 56 pdf_text
12 12. Revise the exception to Section 1029.8.1 by deleting "smoke-protected or." 105 pdf_text
12 12. Insert the following standards under NFPA: "25–17: Standard for the Inspection, Testing and Maintenance of Water-based Fire Protection Systems" "914–15: Code for Fire Protection of Historic Structures" 217 pdf_text
12 12. Revise Section 717.5.5 by replacing "at each point" with "adjacent to each point." 62 pdf_text
12.1 12.1. Revise Section 2702.15 by deleting "as required in Section 415.11.10." 196 pdf_text
12.1 12.1. Revise the third sentence of Section 2603.5 to read: "Exterior walls of buildings of Type V construction shall comply with Sections 2603.2, 2603.3, 2603.4 and 2603.5.7 192 pdf_text
120 120. Insert the following definition: "GOVERNMENTAL UNIT. State agencies, as defined in the State Auditing Act, 30 ILCS 5/, circuit courts, units o government and their officers, boards of election commissioners, public colleges and universities and school districts 10 pdf_text
1202.5.1 1202.5.1 Ventilation area required. The net openable area of the openings to the outdoors, without regard for window opening control devices or be at least 4 percent of the floor area being ventilated. 121 pdf_text
1202.5.1.1 1202.5.1.1 Adjoining spaces. For the purpose of natural ventilation, any space is permitted to be considered as a portion of an adjoi where at least one-half of the area of the common wall is open and unobstructed and provides an open than 10 percent of the floor area of the interior space or 25 square feet (2.32 m2), whichever is greater. openable area shall be at least 4 percent of the aggregate floor area. 121 pdf_text
1202.5.1.2 1202.5.1.2 Remote rooms. Where rooms and spaces without openings to the outdoors are ventilated through an adjoining room, t the adjoining room shall either: 121 pdf_text
1202.5.1.3 1202.5.1.3 Residential basements. Where at least 40 percent of the net floor area of a Group R dwelling unit, not used as congregate livi located entirely above grade and provided with natural ventilation as required in this section, basemen occupiable spaces may be provided with mechanical ventilation and exhaust providing at least 0.35 ai hour in lieu of natural ventilation openings. 121 pdf_text
1202.5.1.4 1202.5.1.4 Openings below grade. Where openings below grade provide required natural ventilation, the outside horizontal clear space perpendicular to the opening shall be one and one-half times the depth of the opening. The depth of th shall be measured from the average adjoining ground level to the bottom of the opening. 121 pdf_text
1202.5.2 1202.5.2 Contaminants exhausted. Contaminant sources in naturally ventilated spaces shall be removed in accordance with the Chicago Mechan the Chicago Fire Prevention Code." 121 pdf_text
1203.2.1 1203.2.1 Group I-1, I-2, I-4 and R-4 occupancies. In Group I-1, I-2, I-4 and R-4 occupancies, indoor spaces intended for human occupancy shall be provided w passive space cooling and dehumidification equipment or systems capable of maintaining an indoor temperat (24ºC) and 50 percent relative humidity at a point 3 feet (914 mm) above the floor when the outdoor temperat (38ºC). 122 pdf_text
1203.2.2 1203.2.2 New Group E, I-3, R-1, R-2, R-3 and R-5 occupancies. In Group E, I-3, R-1, R-2, R-3 and R-5 occupancies constructed or established after the effective date of the a ordinance of 2022, indoor spaces intended for human occupancy shall be provided with active or passive spa dehumidification equipment or systems capable of maintaining an indoor temperature of 75ºF (24ºC) and 50 humidity at a point 3 feet (914 mm) above the floor when the outdoor temperature is 92ºF (33ºC) and the mea wet bulb temperature is 75ºF (24ºC)." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 57; Amend Coun. J. 6-22-22, p. 49372, § 5) 122 pdf_text
1204.2.1 1204.2.1 Direct natural light. The room shall be provided with exterior openings with a net glazed area of at least 8 percent of the floor are 122 pdf_text
1204.2.2 1204.2.2 Adjoining spaces. For the purpose of natural lighting, any room is permitted to be considered as a portion of an adjoining room one-half of the area of the common wall is open and unobstructed and provides an opening of not less than 10 floor area of the interior room or 25 square feet (2.32 m2), whichever is greater. The net glazed area of exteri 122 pdf_text
1204.2.3 1204.2.3 Remote rooms. A room without sufficient exterior openings is permitted to borrow natural lighting from an adjoining room t requirements of Section 1204.2.1 if the remote room, adjoining room and exterior openings meet all of the fo criteria: 123 pdf_text
1204.2.4 1204.2.4 Residential basements. Where at least 40 percent of the net floor area of a Group R dwelling unit, not used as congregate living facili entirely above grade and provided with natural light in accordance with Section 1204.2.1 or 1204.2.2, basem be provided with natural light as follows: 123 pdf_text
1204.2.5 1204.2.5 Exterior openings. Exterior openings required by Section 1204.2 for natural light shall open directly onto a public way or a yard complying with Section 1205. Exceptions: 123 pdf_text
1204.2.6 1204.2.6 Openings below grade. Where openings below grade are used to provide required natural light, the outside horizontal clear space me perpendicular to the opening shall be one and one-half times the depth of the opening. The depth of the openi measured from the average adjoining ground level to the bottom of the opening." 123 pdf_text
1205.1 1205.1 General. This section shall apply to yards and courts adjacent to exterior openings that provide natural light or natural ventilat yards and courts shall be on the same lot as the building. For purposes of this section, width shall be measured perpe plane of openings and length shall be measured parallel to the plane of openings. 124 pdf_text
1205.2 1205.2 Yards. Yards shall be not less than 3 feet (914 mm) in width for an exterior wall not more than 40 feet (12.2 m) in height ab floor receiving natural light or natural ventilation or grade plane, whichever is higher. Where the exterior wall excee (12.2 m) in height, the minimum width of the yard shall be increased 2 inches (76 mm) for each 1 foot (305 mm) or f in height up to a maximum width of 15 feet (4572 mm). 124 pdf_text
1205.3 1205.3 Courts. The length of a court shall be at least 150% of the horizontal dimension of required openings. Outer courts shall com 124 pdf_text
1205.3.2 1205.3.2 Outer courts. Outer courts shall be not less than 3 feet (914 mm) in width for an exterior wall not more than 40 feet (12.2 above the lowest floor receiving natural light or natural ventilation or grade plane, whichever is higher. Wher wall exceeds 40 feet (12.2 m) in height, the minimum width of the outer court shall be increased 2 inches (76 124 pdf_text
1205.3.3 1205.3.3 Inner courts. Inner courts shall be not less than 6 feet (1829 mm) in width for an exterior wall not more than 40 feet (12.2 above the lowest floor receiving natural light or natural ventilation or grade plane, whichever is higher. Wher wall exceeds 40 feet (12.2 m) in height, the minimum width of the inner court shall be increased 4 inches (10 each 1 foot (305 mm) or fraction thereof in height up to a maximum width of 15 feet (4572 mm). For irregula inner courts, the average width shall be at least as great as the minimum width required by this section and th not be less than 5 feet (1524 mm) at any point. 124 pdf_text
1205.3.3.1 1205.3.3.1 Court access. Access shall be provided to the bottom of inner courts for cleaning purposes. 124 pdf_text
1205.3.3.2 1205.3.3.2 Air intake. Inner courts more than two stories in height shall be provided with a horizontal air intake at the botto sectional area not less than 10 square feet (0.93 m 2 ) and leading to a yard or public way. Air intakes construction having a fire-resistance rating of not less than two hours and shall be open at both ends unobstructed for their full size and length, except that grilles of noncombustible construction are perm ends. Exception: In buildings equipped throughout with an automatic sprinkler system in accordanc 124 pdf_text
1205.3.3.3 1205.3.3.3 Court drainage. The bottom of every inner court shall be properly graded and drained to a public sewer or other appro system complying with the Chicago Plumbing Code. 124 pdf_text
1205.4 1205.4 Easements. The building official may adopt rules for considering permanent and perpetual easements or restrictive declarations o lots as a means of creating spaces equivalent to courts or yards." (Amend Coun. J. 6-25-21, p. 32180, Art. II, § 22; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 16) 124 pdf_text
1207.1 1207.1 Minimum room dimensions. Kitchens shall have a clear passageway of not less than 3 feet (914 mm) between counter fronts and appliances or co walls. Exception: Within a dwelling unit having a net floor area not exceeding 700 square feet (65 m2) and not req Accessible unit, Type A unit, Type B unit or Type C unit, a clear working space of not less than 30 inches (762 provided in front of kitchen counters and kitchen appliances. 125 pdf_text
1207.2 1207.2 Minimum ceiling heights. Occupiable spaces and corridors shall have a ceiling height of not less than 7 feet 6 inches (2286 mm) above the fini Exceptions: 125 pdf_text
1207.2.1 1207.2.1 Furred ceiling or projecting elements. Any room with a furred ceiling or projecting elements, such as beams, girders, ducts, or pipes, shall be requir minimum ceiling height in three-quarters of the area thereof, and in no case shall the clearance below a furred projecting element be less than 80 inches (2032 mm) above the finished floor. Exception: Within a dwelling unit or sleeping unit in a Group R occupancy, the clearance below a fur projecting element shall not be less than 6 feet 4 inches (1931 mm). 125 pdf_text
1207.3 1207.3 Room area. Every dwelling unit shall have at least one room that shall have not less than 120 square feet (11.2 m2) of net floor ar spaces shall have a net floor area of not less than 60 square feet (5.6 m2). Other habitable spaces shall have a net floo less than 70 square feet (6.5 m2). Where a single room is provided for cooking, dining and living purposes, it shall ha area of not less than 180 square feet (16.7 m2). 125 pdf_text
1207.5 1207.5 Lofts. Lofts used for sleeping or living space within a dwelling unit or sleeping unit in a Group R occupancy, and not contai providing exclusive means of access to any plumbing fixture, shall conform to the minimum requirements of this cod follows: 125 pdf_text
1207.5.1 1207.5.1 Accessibility. Lofts shall not be allowed within Accessible units and Type A units. Within Type B units, lofts shall not contai living or sleeping space, and all other spaces within the unit shall be on an accessible route. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 58; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 26; Amend Coun. J. 12-14-2 Art. III, § 6) 126 pdf_text
121 121. Revise the definition of "grade plane" to read: "GRADE PLANE. A reference plane established in accordance with Section 203.2." 10 pdf_text
1210.1 1210.1 General. Buildings containing rooms and spaces in which people live, sleep or work, or in which feed, food or foodstuffs are s prepared, processed, served or sold, shall be constructed in accordance with the provisions of this section. 126 pdf_text
1210.2 1210.2 Ventilation openings. Ventilation openings in exterior walls located less than 2 feet (610 mm) above the adjacent ground level shall be cov entire height and width with perforated sheet metal plates not less than 0.070 inch (1.8 mm) thick, expanded sheet m less than 0.047 inch (1.2 mm) thick, cast-iron grills or grating, extruded aluminum load-bearing vents, hardware clot (0.89 mm) wire or heavier, or other approved material providing equivalent protection against the entry of rodents. T therein shall not exceed 1/4 inch (6.4 mm). 126 pdf_text
1210.3 1210.3 Windows. When closed, the maximum clearance between any exterior window, window jambs and sills, where the window sill than 2 feet (610 mm) above the adjacent ground level shall be not greater than 3/8 inch (9.5 mm). 126 pdf_text
1210.4 1210.4 Exterior wall penetrations. Annular spaces around pipes, electric cables, conduits and similar openings in exterior walls shall be protected again of rodents by closing such openings with cement mortar, concrete masonry or noncorrosive metal. 127 pdf_text
1210.5 1210.5 Doors. When closed, the maximum clearance between any exterior door, door jambs and sills shall be not greater than 3/8 in (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 59) 127 pdf_text
1211.1 1211.1 General. Every exterior door, operable window and other outside opening used to provide ventilation for habitable spaces, fo areas, food service areas, or areas where products to be included or utilized in food for human consumption are proce manufactured, packed or stored shall be supplied with tightly fitting screens of minimum 16 mesh per inch (16 mesh Every screen door provided for insect control shall be self-closing. Exceptions: 127 pdf_text
1212.1 1212.1 General. Building entrances and each dwelling unit in buildings containing more than one Group I-1, R-2, R-3, R-4 or R-5 dw shall be provided with security devices in accordance with Section 403 of the Chicago Minimum Requirements for E Buildings." (Added Coun. J. 2-19-20, p. 14473, Art. II, § 61) CHAPTER 14B-13 ENERGY EFFICIENCY 127 pdf_text
122 122. Insert the following definition: "GROSS FLOOR AREA. See "Floor area, gross." 10 pdf_text
123 123. Delete the definition of "gross leasable area." 10 pdf_text
124 124. Revise the definition of "group home" to read: "GROUP HOME. A facility for social rehabilitation, substance abuse or mental health problems that contains a gro arrangement that provides custodial care but does not provide medical care." 10 pdf_text
125 125. Revise the definition of "guest room" to read: "GUEST ROOM. A room or suite of rooms used or intended to be used for rent or for hire by one or more guests fo sleeping purposes and located within a dwelling unit or a sleeping unit." 10 pdf_text
126 126. Revise the definition of "habitable space" to read: "HABITABLE SPACE. A space in a building for recreation, working, sleeping, eating or cooking. Bathrooms, toile closets, halls, incidental storage or utility spaces and similar areas are not considered habitable spaces." 10 pdf_text
127 127. Revise the definition of "hazardous materials" to read: "HAZARDOUS MATERIALS. As defined in Chapter 2 of the Chicago Fire Prevention Code." 10 pdf_text
128 128. Revise the definition of "hazardous production material (HPM)" to read: "HAZARDOUS PRODUCTION MATERIAL (HPM). As defined in Chapter 2 of the Chicago Fire Prevention C 10 pdf_text
129 129. Revise the definition of "health hazard" to read: "HEALTH HAZARD. As defined in Chapter 2 of the Chicago Fire Prevention Code." 10 pdf_text
13 13. Revise Section 1202.5 and its subsections to read: "1202.5 Natural ventilation. Where required, natural ventilation shall be through windows, doors, louvers or other openings to the outdoors that o public way or a yard or court complying with Section 1205. The operating mechanism for such openings shall be rea controllable by the occupants of the room or space served. 121 pdf_text
13 13. Revise Section 1404.10.1.2.1 to read: "1404.10.1.2.1 Flashing at foundation. A corrosion-resistant screed or flashing shall be installed to extend below the foundation plate line on exterior stud w accordance with Section 1404.4. The water-resistive barrier shall lap over the exterior of the attachment flange of th flashing." 130 pdf_text
13 13. Delete exception 2 to Section 1006.3.1. 89 pdf_text
13 13. Delete the definition of "anchor building." 4 pdf_text
13 13. Revise the title and first sentence of Section 1803.5.12 to read: "1803.5.12 Seismic Design Category D. For structures assigned to Seismic Design Category D, the geotechnical investigation required by Section 1803.5.11 all of the following as applicable:" 164 pdf_text
13 13. Revise Section 1507.12.2 by deleting "ASTM D5019." 137 pdf_text
13 13. Fire-retardant treated wood veneers conforming to Section 1404.5 not extending above the seco grade plane. 219 pdf_text
13 13. Add a new Section 1107.6.1.3 to read: 113 pdf_text
13 13. Delete Section 403.4.5. 25 pdf_text
13 13. Revise the title and first sentence of Section 903.2.4 to read: "903.2.4 Group F. An automatic sprinkler system shall be provided throughout all buildings containing a Group F occupancy where on following conditions exists:" 68 pdf_text
13 13. Revise the second and third sentences of Section 1808.8.3 to read: "1808.8.3 Placement of concrete. Concrete shall not be placed through water unless a tremie or other approved method is used. Where placed under or presence of water, the concrete shall be deposited by means to ensure minimum segregation of the mix and negligibl the water." 169 pdf_text
13 13. A Building Information Card that contains, information specified in rules adopted by the fire cod 80 pdf_text
13 13. Revise the first sentence of Section 1011.10 to read: "Spiral stairways are permitted to be used as a component in the means of egress in the following locations only: 97 pdf_text
13 13. Revise Section 2303.4.6 by deleting the last sentence. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 83) 184 pdf_text
13 13. Revise the second sentence of Section 1705.8 to read: "The geotechnical report prepared by the registered geotechnical engineer and the permitted construction documents to determine compliance." 158 pdf_text
13 13. Delete the entire section for PTI. 217 pdf_text
13 13. An outdoor area as provided in the exceptions to Section 1004.7." 90 pdf_text
13 13. Revise Section 2603.7 to read: "2603.7 Foam plastic as interior finish or interior trim in plenum-served spaces. Foam plastic used as interior wall or ceiling finish, or interior trim in plenum-served spaces, shall exhibit a flame spr or less and a smoke-developed index of 50 or less when tested in accordance with ASTM E84 or UL 723 at the maxi and density intended for use, and shall be tested in accordance with NFPA 286 and meet the acceptance criteria of Se As an alternative to testing to NFPA 286, the foam plastic may be approved based on tests conducted in accordance 193 pdf_text
13 13. Revise Section 905.7.1 by deleting "in an approved manner." 73 pdf_text
13 13. Delete Section 2702.2.17. 196 pdf_text
13 13. Revise exception 5 to Section 1010.1.5 to read: "5. Exterior decks, patios or exterior balconies that are part of Type B dwelling units, have impervious surfa not more than 4 inches (102 mm) below the finished floor level of the adjacent interior space of the dwelling 93 pdf_text
13 13. Add a new exception 7 to Section 706.6 to read: "7. Offset construction in accordance with Section 706.6.3." 58 pdf_text
13 13. Revise Sections 2304.12.2.1, 2304.12.2.2, 2304.12.2.3, 2304.12.2.4 and 2304.12.2.5 to replace "naturally durab preservative-treated wood" with "naturally durable wood or preservative-treated wood." 184 pdf_text
13 13. Add new exception 4 to Section 705.8.5 to read: "4. This section shall not apply to Group R-5 buildings." 56 pdf_text
13 13. Revise Section 1004.6 by deleting the last sentence. 86 pdf_text
13 13. Delete Section 406.5.5. 30 pdf_text
13 13. Add a new exception to Section 717.5.6 to read: "Exception: Fire dampers are not required in residential kitchen and clothes dryer exhaust systems." 62 pdf_text
13 13. Revise Section 1810.3.3 to read: "1810.3.3 Determination of allowable loads. The allowable axial and lateral loads on deep foundation elements shall be determined by an accepted engineering an tests." 171 pdf_text
13 13. Delete Section 2308.4.10. 186 pdf_text
13 13. Revise Section D103.1 to read: 218 pdf_text
13 13. Revise exceptions 3 and 4 to Section 1029.9.5 by deleting "smoke-protected or." 105 pdf_text
13 13. Revise the exceptions to Section 907.2.6 to read: "Exception: Occupant notification systems are not required to be activated where private operating mode signaling i accordance with NFPA 72 is permitted by the fire code official and staff evacuation responsibilities are included in t and evacuation plan required by the Chicago Fire Prevention Code." 74 pdf_text
13 13. Revise note d to Table 1607.1 by replacing "an approved method" with "an accepted engineering practice." 147 pdf_text
13 13. Revise Section 1805.4.2 to read: "1805.4.2 Foundation drain. A drain shall be placed at the perimeter of the foundation." 165 pdf_text
13.1 13.1 Revise item 4 in Section 903.2.4 to read: "4. A Group F-1 fire area used for the manufacture of upholstered furniture or mattresses exceeds 2,500 squ m 2 )." 68 pdf_text
13.1 13.1. Revise Section 706.6.1 to read: "Where a fire wall separates buildings having different roof levels, the fire wall shall terminate at a point not less tha (762 mm) vertically above the lower roof level provided that within 15 feet (4572 mm) above the lower roof level th shall have a fire-resistance rating of not less than 1 hour and opening protectives shall have a fire protection rating o 58 pdf_text
130 130. Revise the definition of "height, building" to read: "HEIGHT, BUILDING. See "Building height." 10 pdf_text
131 131. Revise the definition of "highly toxic" to read: "HIGHLY TOXIC. As defined in Chapter 2 of the Chicago Fire Prevention Code." 10 pdf_text
132 132. Revise the definition of "high-rise building" to read: "HIGH-RISE BUILDING. A building greater than 80 feet (24.4 m) in building height." 10 pdf_text
133 133. Revise the definition of "historic buildings" to read: "HISTORIC BUILDINGS. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 10 pdf_text
134 134. Insert the following definition: "HOTEL. A building kept, used, maintained as, advertised or held out to the public to be an inn, hotel, motel, family apartment hotel, boarding house, lodging house, dormitory or other place where sleeping or rooming accommodation for hire or rent on a transient basis, either with or without meals, excluding bed-and-breakfast establishments." 10 pdf_text
135 135. Insert the following definition: "HOUSEHOLD. As defined in Chapter 17-17 of the Chicago Zoning Ordinance." 10 pdf_text
136 136. Delete the definition of "hurricane-prone regions." 10 pdf_text
137 137. Revise the definition of "hydrogen fuel rooms" to read: 10 pdf_text
138 138. Insert the following definition: "ILLINOIS ACCESSIBILITY CODE. Rules adopted by the State of Illinois pursuant to the Environmental Barrie ILCS 25." 11 pdf_text
139 139. Revise the definition of "immediately dangerous to life and health (IDLH)" to read: "IMMEDIATELY DANGEROUS TO LIFE AND HEALTH (IDLH). As defined in Chapter 2 of the Chicago Fi Code." 11 pdf_text
14 14. Revise the first two sentences of Section 2308.5.5.1 to read: "Headers shall be provided over each opening in exterior bearing walls. The size and spans in Table 2308.4.1.1(1) ar be used for Group R-5 occupancies." 186 pdf_text
14 14. Revise Section 903.2.4.1 by replacing "fire areas" with "buildings." 68 pdf_text
14 14. Revise Section 905.9 by adding the following after the last sentence: "All valves in supply pipes to standpipe systems shall be secured open." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 31; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 15)) 73 pdf_text
14 14. Revise note k to Table 1607.1 by replacing "habitable attics and sleeping rooms" with "all other areas." 147 pdf_text
14 14. Revise Section 1404.10.2 to read: "1404.10.2 Exterior adhered masonry veneers- porcelain tile. Adhered porcelain tile units shall not exceed 5/8 inch (15.8 mm) thickness and 24 inches (610 mm) in any face dime than 3 square feet (0.28 m2) in total face area and shall not weigh more than 9 pounds psf (0.43 kN/m2). Porcelain til adhered to a backing system." 130 pdf_text
14 14. Delete the exception to Section 2304.12.2.3. 184 pdf_text
14 14. Delete Section 717.5.7. 62 pdf_text
14 14. Add a new Section 706.6.3 to read: "706.6.3 Offset construction. Where a fire wall is offset at an intermediate floor level, the offset floor and its supporting construction shall have a f rating of not less than 4 hours. Interior exit stairways and interior exit ramps shall not penetrate the horizontal offset 58 pdf_text
14 14. Single-story buildings of Type IIB construction not exceeding 5,000 square feet (465 m2) in area walls with a fire separation distance of less than 30 feet (9144 mm) shall have a fire- resistance rating than 1 hour. 219 pdf_text
14 14. Revise Section 1808.8.6 by replacing "Seismic Design Category C, D, E or F" with "Seismic Design Category Seismic Design Category D, E or F" with "Seismic Design Category D" and "Detached one- and two- family dwellin "Group R-5 occupancies." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 80) 169 pdf_text
14 14. Revise Section 1006.3.2 to read: "1006.3.2 Egress based on occupant load. Each story and occupiable rooftop shall have the minimum number of separate and distinct exits, or access to exits, a Table 1006.3.2. A single exit or access to a single exit shall be permitted in accordance with Section 1006.3.3. The re of exits, or exit access stairways or ramps providing access to exits, from any story or occupiable rooftop shall be ma arrival at the exit discharge or a public way. Exception: Two exits shall be permitted from a story separated by fire barriers into two areas of approximate that are connected by a horizontal exit where the occupant load of each area does not exceed 300." 89 pdf_text
14 14. Delete Section D104. 219 pdf_text
14 14. Delete Section 2603.8 and Figure 2603.8. 193 pdf_text
14 14. Revise the definition of "anchored masonry veneer" to read: "ANCHORED MASONRY VENEER. Veneer secured with mechanical fasteners to a backing." 4 pdf_text
14 14. Delete the following standard under UL: 1975–06. 217 pdf_text
14 14. Revise Section 1011.11 to read: "1011.11 Handrails. Flights of stairs shall have handrails on each side and shall comply with Section 1014. Where glass is used to provid the handrail, the handrail or support shall comply with Section 2407. Exceptions: 97 pdf_text
14 14. Revise Section the second sentence of 1705.9 to read: "The geotechnical report prepared by the registered geotechnical engineer and the permitted construction documents to determine compliance." 158 pdf_text
14 14. Revise Section 403.4.6 to read: "403.4.6 Fire command. A fire command center complying with Section 911 shall be provided in a location acceptable to the fire code official 25 pdf_text
14 14. Revise Section 705.8.6 to read: "Where fire separation distance is based on an imaginary line between buildings on the same lot and is less than 15 f mm), every opening that is less than 15 feet (4572 mm) vertically above the roof of adjacent buildings on the same l provided with opening protectives having a fire protection rating of not less than 3/4 hour. Exceptions: 56 pdf_text
14 14. Delete Section 1202.6. 121 pdf_text
14 14. Revise Section 1004.7 to read: "1004.7 Outdoor areas. Where occupants are provided access to yards, patios, decks, exterior balconies, occupiable rooftops, courts and sim areas, the outdoor areas shall be provided with means of egress as required by this chapter. The occupant load of suc areas shall be calculated in accordance with the anticipated use. Where the path of egress travel from the outdoor are through the building, means of egress requirements for the building shall be based on the sum of the occupant loads plus the outdoor areas. Exceptions: 86 pdf_text
14 14. Revise the first two sentences of Section 1810.3.3.1.1 to read: "The allowable compressive load on any driven deep foundation element where determined by the application of a dr shall not exceed 60 tons (598 kN) on soil and 100 tons (996 kN) on rock. For allowable loads above those values, the equation method of analysis shall be used to estimate driveability for both driving stresses and net displacement per ultimate load." 171 pdf_text
14 14. Revise Section 406.5.6 by replacing "adjacent lot line" with "abutting property line." Revise Section 406.5.7 to read: "406.5.7 Means of egress. Where persons other than parking attendants are permitted, open parking garages shall meet the means of egress req Chapter 10. Where persons other than parking attendants are not permitted, there shall be not fewer than two exit stai exit stairway shall be not less than 30 inches (762 mm) in width. Personnel lifts shall be permitted to be installed for employees only, provided that they are completely enclosed by noncombustible materials." 30 pdf_text
14 14. Delete Section 2702.3. 196 pdf_text
14 14. Revise Section 1805.4.3, excluding the exception, to read: "1805.4.3 Drainage discharge. The floor base course and foundation perimeter drain shall discharge by gravity or mechanical means into a drainage complies with the Chicago Plumbing Code." 165 pdf_text
14 14. Revise Section 1107.6.2 and its subsections to read: "1107.6.2 Groups R-2 and R-3. Accessible units, Type A units and Type B units shall be provided in Group R-2 and R-3 occupancies in accordance w 114 pdf_text
14 14. Revise the exception to Section 1029.13.2.1 by deleting "smoke-protected or." 105 pdf_text
14 14. Revise Section 1010.1.6 to read: "1010.1.6 Landings at doors. Landings shall have a width not less than the width of the stairway or the door, whichever is greater. Doors in the ful position shall not reduce a required dimension by more than one-quarter its required width. Landings shall have a len in the direction of travel of not less than 44 inches (1118 mm). Exception: Landing length in the direction of travel in Groups R-3, R-5 and U and within individual units of need not exceed 36 inches (914 mm)." 93 pdf_text
14 14. Revise item 5 in Section 1803.6 to replace "expansive" with "questionable." 164 pdf_text
14 14. Revise Section 907.2.6.1.1 by replacing "smoke alarms" with "smoke alarms, heat alarms and heat detectors" in heading and body. 74 pdf_text
14 14. Revise Section 1507.12.3 to read: "1507.12.3 Ballasted thermoset low-sloped roofs. Ballasted thermoset low-sloped roofs shall be installed in accordance with this section and Section 1504.4. Stone use shall comply with ASTM D448 or ASTM D7655." 137 pdf_text
14.1 14.1. Insert the following standards under UL: "521–99: Heat Detectors for Fire Protective Signaling Systems – with Revisions through March 2021 217 pdf_text
140 140. Revise the definition of "incompatible materials" to read: "INCOMPATIBLE MATERIALS. As defined in Chapter 2 of the Chicago Fire Prevention Code." 11 pdf_text
1404.14.1 1404.14.1 Application. The siding shall be applied over sheathing or materials listed in Section 2304.6. Siding shall be applied to con water-resistive barrier requirements in Section 1402. Siding and accessories shall be installed in accordance manufacturer’s written instructions. Unless otherwise specified in the manufacturer’s instructions, nails used siding and accessories shall have a minimum 0.313-inch (7.9 mm) head diameter and 1/8-inch (3.18 mm) sha The nails shall be corrosion resistant and shall be long enough to penetrate the studs or nailing strip not less t (19 mm). For cold-formed steel light-frame construction, corrosion-resistant fasteners shall be used. Screw fa penetrate the cold-formed steel framing not fewer than three exposed threads. Other fasteners shall be installe accordance with the permitted construction documents and manufacturer’s instructions. Where the siding is i horizontally, the fastener spacing shall not exceed 16 inches (406 mm) horizontally and 12 inches (305 mm) Where the siding is installed vertically, the fastener spacing shall not exceed 12 inches (305 mm) horizontally (305 mm) vertically." 131 pdf_text
1405.1.1.1.2 1405.1.1.1.2 Fire separation greater than 15 feet. For fire separation distances greater than 15 feet ( 4572 mm), any exterior wall covering shall be allowed tha exposed to a reduced level of incident radiant heat flux in accordance with the NFPA 268 test method withou 131 pdf_text
1406.10.4 1406.10.4 provided that such systems comply with Section 1406.11.1. 132 pdf_text
1406.11.1 1406.11.1 Installations up to 40 feet in height. MCM shall not be installed more than 40 feet (12 190 mm) in height above grade plane where installed in ac Sections 1406.11.1.1 and 1406.11.1.2. 132 pdf_text
1406.11.1.1 1406.11.1.1 Fire separation distance of 15 feet or less. Where the fire separation distance is 15 feet ( 4572 mm) or less, the area of MCM shall not exceed 1 exterior wall surface. 132 pdf_text
1406.11.1.2 1406.11.1.2 Fire separation distance greater than 15 feet. Where the fire separation distance is greater than 15 feet ( 4572 mm), the area of exterior wall surfac using MCM shall not be limited." 132 pdf_text
1407.4.1.1 1407.4.1.1 Water-resistive barrier. The water-resistive barrier shall comply with Section 1403.2 or ASTM E2570." 132 pdf_text
1408.11.1 1408.11.1 Installations up to 40 feet in height. HPL shall not be installed more than 40 feet (12 190 mm) in height above grade plane where installed in acc Sections 1408.11.1.1 and 1408.11.1.2. 133 pdf_text
1408.11.1.1 1408.11.1.1 Fire separation distance of 15 feet or less. Where the fire separation distance is 15 feet (4572 mm) or less, the area of HPL shall not exceed 10 p exterior wall surface. 133 pdf_text
1408.11.1.2 1408.11.1.2 Fire separation distance greater than 15 feet. Where the fire separation distance is greater than 15 feet (4572 mm), the area of exterior wall surface using HPL shall not be limited." 133 pdf_text
141 141. Revise the definition of "inert gas" to read: "INERT GAS. As defined in Chapter 2 of the Chicago Fire Prevention Code." 11 pdf_text
142 142. Delete the definition of "jurisdiction." 11 pdf_text
143 143. Delete the definition of "limit of moderate wave action." 11 pdf_text
144 144. Revise the definition of "liquid" to read: "LIQUID. As defined in Chapter 2 of the Chicago Fire Prevention Code." 11 pdf_text
145 145. Revise the definition of "live/work unit" to read: "LIVE/WORK UNIT. A dwelling unit in which a significant portion of the space includes a nonresidential use that a resident." 11 pdf_text
146 146. Revise the definition of "lodging house" to read: "LODGING HOUSE. A building with not more than four stories above grade plane or a dwelling unit where one o occupant is primarily permanent in nature and rent is paid for guest rooms." 11 pdf_text
147 147. Insert the following definition: "LOFT. A floor level located above the main floor level within a dwelling unit or sleeping unit, open to the main flo one side and used as a living or sleeping space." 11 pdf_text
148 148. Revise the definition of "lot" to read: "LOT. As defined in Chapter 17-17 of the Chicago Zoning Ordinance. Lot of record. As defined in Chapter 17-17 of the Chicago Zoning Ordinance. Zoning lot. As defined in Chapter 17-17 of the Chicago Zoning Ordinance." 11 pdf_text
149 149. Revise the definition of "lot line" to read: "LOT LINE. See "Property line." 11 pdf_text
14B 14B-[IBC chapter number]-[IBC section number] Provided that the appendices shall be deemed to be part of a new Chapter 36. 2 pdf_text
14B-1-001 14B-1-001 Adoption of the International Building Code by reference. 2 pdf_text
14B-1-001 14B-1-001 Adoption of the International Building Code by reference. The International Building Code, 2018 edition, first printing, and all erratum thereto identified by the publisher (hereinafter "IBC") is adopted by reference and shall be considered part of the requirements of this title except as modified by the specifi this title. If a conflict exists between a provision modified by this title and a provision adopted without modification, the modified pro control. 2 pdf_text
14B-1-002 14B-1-002 Citations. Provisions of IBC which are incorporated into this title by reference may be cited as follows: 2 pdf_text
14B-1-003 14B-1-003 Global modifications. The following modifications shall apply to each provision of IBC incorporated into this title: 2 pdf_text
14B-1-003 14B-1-003 Global modifications. 2 pdf_text
14B-1-100 14B-1-100 Chapter 1. The provisions of Chapter 1 of IBC are not adopted. The following is adopted as Chapter 1: "CHAPTER 1. SCOPE AND PURPOSE 2 pdf_text
14B-10-1001 14B-10-1001 Administration. The provisions of Section 1001 of IBC are adopted by reference with the following modifications: 84 pdf_text
14B-10-1002 14B-10-1002 Maintenance and plans. 83 pdf_text
14B-10-1002 14B-10-1002 Maintenance and plans. The provisions of Section 1002 of IBC are adopted by reference with the following modifications: 84 pdf_text
14B-10-1003 14B-10-1003 General means of egress. 83 pdf_text
14B-10-1003 14B-10-1003 General means of egress. The provisions of Section 1003 of IBC are adopted by reference with the following modifications: 84 pdf_text
14B-10-1004 14B-10-1004 Occupant load. The provisions of Section 1004 of IBC are adopted by reference with the following modifications: 85 pdf_text
14B-10-1004 14B-10-1004 Occupant load. 83 pdf_text
14B-10-1005 14B-10-1005 Means of egress sizing. The provisions of Section 1005 of IBC are adopted by reference with the following modifications: 87 pdf_text
14B-10-1005 14B-10-1005 Means of egress sizing. 83 pdf_text
14B-10-1006 14B-10-1006 Number of exits and exit access doorways. The provisions of Section 1006 of IBC are adopted by reference with the following modifications: 87 pdf_text
14B-10-1006 14B-10-1006 Number of exits and exit access doorways. 83 pdf_text
14B-10-1007 14B-10-1007 Exit and exit access doorway configuration. The provisions of Section 1007 of IBC are adopted by reference with the following modifications: 91 pdf_text
14B-10-1007 14B-10-1007 Exit and exit access doorway configuration. 83 pdf_text
14B-10-1008 14B-10-1008 Means of egress illumination. 83 pdf_text
14B-10-1008 14B-10-1008 Means of egress illumination. The provisions of Section 1008 of IBC are adopted by reference with the following modifications: 91 pdf_text
14B-10-1009 14B-10-1009 Accessible means of egress. 83 pdf_text
14B-10-1009 14B-10-1009 Accessible means of egress. The provisions of Section 1009 of IBC are adopted by reference with the following modifications: 92 pdf_text
14B-10-1010 14B-10-1010 Doors, gates and turnstiles. The provisions of Section 1010 of IBC are adopted by reference with the following modifications: 92 pdf_text
14B-10-1010 14B-10-1010 Doors, gates and turnstiles. 83 pdf_text
14B-10-1011 14B-10-1011 Stairways. The provisions of Section 1011 of IBC are adopted by reference with the following modifications: 95 pdf_text
14B-10-1012 14B-10-1012 Ramps. The provisions of Section 1012 of IBC are adopted by reference with the following modifications: 98 pdf_text
14B-10-1013 14B-10-1013 Exit signs. 83 pdf_text
14B-10-1013 14B-10-1013 Exit signs. The provisions of Section 1013 of IBC are adopted by reference with the following modifications: 98 pdf_text
14B-10-1014 14B-10-1014 Handrails. The provisions of Section 1014 of IBC are adopted by reference with the following modifications: 99 pdf_text
14B-10-1015 14B-10-1015 Guards. The provisions of Section 1015 of IBC are adopted by reference with the following modifications: 99 pdf_text
14B-10-1016 14B-10-1016 Exit access. 83 pdf_text
14B-10-1016 14B-10-1016 Exit access. The provisions of Section 1016 of IBC are adopted by reference with the following modification: 100 pdf_text
14B-10-1017 14B-10-1017 Exit access travel distance. 83 pdf_text
14B-10-1017 14B-10-1017 Exit access travel distance. The provisions of Section 1017 of IBC are adopted by reference with the following modifications: 100 pdf_text
14B-10-1018 14B-10-1018 Aisles. The provisions of Section 1018 of IBC are adopted by reference without modification. 101 pdf_text
14B-10-1019 14B-10-1019 Exit access stairways and ramps. 83 pdf_text
14B-10-1019 14B-10-1019 Exit access stairways and ramps. The provisions of Section 1019 of IBC are adopted by reference with the following modifications: 101 pdf_text
14B-10-1020 14B-10-1020 Corridors. The provisions of Section 1020 of IBC are adopted by reference with the following modifications: 101 pdf_text
14B-10-1021 14B-10-1021 Egress balconies. The provisions of Section 1021 of IBC are adopted by reference with the following modification: 102 pdf_text
14B-10-1021 14B-10-1021 Egress balconies. 83 pdf_text
14B-10-1022 14B-10-1022 Exits. The provisions of Section 1022 of IBC are adopted by reference without modification. 102 pdf_text
14B-10-1023 14B-10-1023 Interior exit stairways and ramps. 84 pdf_text
14B-10-1023 14B-10-1023 Interior exit stairways and ramps. 102 pdf_text
14B-10-1024 14B-10-1024 Exit passageways. 84 pdf_text
14B-10-1024 14B-10-1024 Exit passageways. The provisions of Section 1024 of IBC are adopted by reference with the following modifications: 103 pdf_text
14B-10-1025 14B-10-1025 IBC Section 1025. 84 pdf_text
14B-10-1025 14B-10-1025 IBC Section 1025. The provisions of Section 1025 of IBC are not adopted. 103 pdf_text
14B-10-1026 14B-10-1026 Horizontal exits. The provisions of Section 1026 of IBC are adopted by reference with the following modification: 103 pdf_text
14B-10-1026 14B-10-1026 Horizontal exits. 84 pdf_text
14B-10-1027 14B-10-1027 Exterior exit stairways and ramps. 84 pdf_text
14B-10-1027 14B-10-1027 Exterior exit stairways and ramps. The provisions of Section 1027 of IBC are adopted by reference with the following modifications: 103 pdf_text
14B-10-1028 14B-10-1028 Exit discharge. The provisions of Section 1028 of IBC are adopted by reference with the following modifications: 104 pdf_text
14B-10-1028 14B-10-1028 Exit discharge. 84 pdf_text
14B-10-1029 14B-10-1029 Assembly. The provisions of Section 1029 of IBC are adopted by reference with the following modifications: 105 pdf_text
14B-10-1030 14B-10-1030 IBC Section 1030. The provisions of Section 1030 of IBC are not adopted. 105 pdf_text
14B-10-1030 14B-10-1030 IBC Section 1030. 84 pdf_text
14B-10-1031 14B-10-1031 Frontage and fire department access requirements for Group E-1. The following language is adopted as a new Section 1031: "1031. FRONTAGE AND FIRE DEPARTMENT ACCESS REQUIREMENTS FOR GROUP E-1 106 pdf_text
14B-10-1031 14B-10-1031 Frontage and fire department access requirements for Group E-1. 84 pdf_text
14B-11-1100 14B-11-1100 Defined terms. 106 pdf_text
14B-11-1100 14B-11-1100 Defined terms. Where provisions of Chapter 11 of IBC are adopted by reference, the following terms shall be reset in italic type: "accessibl "disability"; "element"; "entrance"; "facility"; "space"; "structure"; "temporary" and "vehicular way." 107 pdf_text
14B-11-1101 14B-11-1101 General. The provisions of Section 1101 of IBC are not adopted. The following language is adopted as Section 1101: "1101. GENERAL 107 pdf_text
14B-11-1102 14B-11-1102 Compliance. The provisions of Section 1102 of IBC are adopted by reference with the following modification: 109 pdf_text
14B-11-1103 14B-11-1103 Scoping requirements. The provisions of Section 1103 of IBC are adopted by reference with the following modifications: 109 pdf_text
14B-11-1103 14B-11-1103 Scoping requirements. 106 pdf_text
14B-11-1104 14B-11-1104 Accessible route. The provisions of Section 1104 of IBC are adopted by reference with the following modifications: 110 pdf_text
14B-11-1104 14B-11-1104 Accessible route. 106 pdf_text
14B-11-1105 14B-11-1105 Accessible entrances. 110 pdf_text
14B-11-1105 14B-11-1105 Accessible entrances. 106 pdf_text
14B-11-1106 14B-11-1106 Parking and passenger loading facilities. 106 pdf_text
14B-11-1106 14B-11-1106 Parking and passenger loading facilities. The provisions of Section 1106 of IBC are adopted by reference with the following modifications: 111 pdf_text
14B-11-1107 14B-11-1107 Dwelling units and sleeping units. The provisions of Section 1107 of IBC are adopted by reference with the following modifications: 112 pdf_text
14B-11-1107 14B-11-1107 Dwelling units and sleeping units. 106 pdf_text
14B-11-1108 14B-11-1108 Special occupancies. 106 pdf_text
14B-11-1108 14B-11-1108 Special occupancies. The provisions of Section 1108 of IBC are adopted by reference with the following modification: 118 pdf_text
14B-11-1109 14B-11-1109 Other features and facilities. 106 pdf_text
14B-11-1109 14B-11-1109 Other features and facilities. The provisions of Section 1109 of IBC are adopted by reference with the following modifications: 118 pdf_text
14B-11-1110 14B-11-1110 Recreational facilities. 107 pdf_text
14B-11-1110 14B-11-1110 Recreational facilities. The provisions of Section 1110 of IBC are adopted by reference with the following modifications: 119 pdf_text
14B-11-1111 14B-11-1111 Signage. The provisions of Section 1111 of IBC are adopted by reference with the following modifications: 119 pdf_text
14B-12-1201 14B-12-1201 General. The provisions of Section 1201 of IBC are adopted by reference with the following modification: 120 pdf_text
14B-12-1202 14B-12-1202 Ventilation. The provisions of Section 1202 of IBC are adopted by reference with the following modifications: 120 pdf_text
14B-12-1203 14B-12-1203 Temperature control. The provisions of Section 1203 of IBC are adopted by reference with the following modifications: 122 pdf_text
14B-12-1203 14B-12-1203 Temperature control. 119 pdf_text
14B-12-1204 14B-12-1204 Lighting. The provisions of Section 1204 of IBC are adopted by reference with the following modifications: 122 pdf_text
14B-12-1205 14B-12-1205 Yards and courts. 120 pdf_text
14B-12-1205 14B-12-1205 Yards and courts. The provisions of Section 1205 of IBC are not adopted. The following language is adopted as Section 1205: "1205. YARDS AND COURTS 124 pdf_text
14B-12-1206 14B-12-1206 IBC Section 1206. The provisions of Section 1206 of IBC are not adopted. 124 pdf_text
14B-12-1206 14B-12-1206 IBC Section 1206. 120 pdf_text
14B-12-1207 14B-12-1207 Interior space dimensions. 120 pdf_text
14B-12-1207 14B-12-1207 Interior space dimensions. The provisions of Section 1207 of IBC are not adopted. The following language is adopted as Section 1207: 124 pdf_text
14B-12-1208 14B-12-1208 Access to unoccupied spaces. The provisions of Section 1208 of IBC are adopted by reference with the following modifications: 126 pdf_text
14B-12-1208 14B-12-1208 Access to unoccupied spaces. 120 pdf_text
14B-12-1209 14B-12-1209 Toilet and bathroom requirements. The provisions of Section 1209 of IBC are adopted by reference with the following modifications: 126 pdf_text
14B-12-1209 14B-12-1209 Toilet and bathroom requirements. 120 pdf_text
14B-12-1210 14B-12-1210 Rodent protection. 120 pdf_text
14B-12-1210 14B-12-1210 Rodent protection. The following language is adopted as a new Section 1210: "1210. RODENT PROTECTION 126 pdf_text
14B-12-1211 14B-12-1211 Insect screens. The following language is adopted as a new Section 1211: "1211. INSECT SCREENS 127 pdf_text
14B-12-1211 14B-12-1211 Insect screens. 120 pdf_text
14B-12-1212 14B-12-1212 Residential security devices. The following language is adopted as a new Section 1212: "1212. RESIDENTIAL SECURITY DEVICES 127 pdf_text
14B-12-1212 14B-12-1212 Residential security devices. 120 pdf_text
14B-13-1301 14B-13-1301 General. The provisions of Section 1301 of IBC are adopted by reference without modification. CHAPTER 14B-14 EXTERIOR WALLS 127 pdf_text
14B-14-1401 14B-14-1401 General. The provisions of Section 1401 of IBC are adopted by reference without modification. 128 pdf_text
14B-14-1402 14B-14-1402 Performance requirements. The provisions of Section 1402 of IBC are adopted by reference with the following modifications: 128 pdf_text
14B-14-1402 14B-14-1402 Performance requirements. 127 pdf_text
14B-14-1403 14B-14-1403 Materials. The provisions of Section 1403 of IBC are adopted by reference with the following modifications: 128 pdf_text
14B-14-1404 14B-14-1404 Installation of wall coverings. 128 pdf_text
14B-14-1404 14B-14-1404 Installation of wall coverings. The provisions of Section 1404 of IBC are adopted by reference with the following modifications: 129 pdf_text
14B-14-1405 14B-14-1405 Combustible materials on the exterior side of exterior walls. 128 pdf_text
14B-14-1405 14B-14-1405 Combustible materials on the exterior side of exterior walls. The provisions of Section 1405 of IBC are adopted by reference with the following modifications: 131 pdf_text
14B-14-1406 14B-14-1406 Metal composite materials (MCM). 128 pdf_text
14B-14-1406 14B-14-1406 Metal composite materials (MCM). The provisions of Section 1406 of IBC are adopted by reference with the following modifications: 132 pdf_text
14B-14-1407 14B-14-1407 Exterior insulation and finish systems (EIFS). The provisions of Section 1407 of IBC are adopted by reference with the following modifications: 132 pdf_text
14B-14-1407 14B-14-1407 Exterior insulation and finish systems (EIFS). 128 pdf_text
14B-14-1408 14B-14-1408 High-pressure decorative exterior-grade compact laminates (HPL). The provisions of Section 1408 of IBC are adopted by reference with the following modifications: 133 pdf_text
14B-14-1408 14B-14-1408 High-pressure decorative exterior-grade compact laminates (HPL). 128 pdf_text
14B-14-1409 14B-14-1409 Plastic composite decking. 128 pdf_text
14B-14-1409 14B-14-1409 Plastic composite decking. The provisions of Section 1409 of IBC are adopted by reference without modification. CHAPTER 14B-15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES 133 pdf_text
14B-15-1500 14B-15-1500 Defined terms. Where provisions of Chapter 15 of IBC are adopted by reference, the following terms shall be reset in italic type: "built-up r "interlayment"; "grade plane"; "metal roof panel"; "metal roof shingle"; "roof assembly"; "roof covering"; "roof covering sy deck"; "rooftop structures"; "single-ply membrane"; "skylights and sloped glazing" and "underlayment." 134 pdf_text
14B-15-1500 14B-15-1500 Defined terms. 133 pdf_text
14B-15-1501 14B-15-1501 General. The provisions of Section 1501 of IBC are adopted by reference with the following modification: 134 pdf_text
14B-15-1502 14B-15-1502 Roof drainage. The provisions of Section 1502 of IBC are adopted by reference with the following modifications: 134 pdf_text
14B-15-1502 14B-15-1502 Roof drainage. 133 pdf_text
14B-15-1503 14B-15-1503 Weather protection. 134 pdf_text
14B-15-1503 14B-15-1503 Weather protection. 134 pdf_text
14B-15-1504 14B-15-1504 Performance requirements. The provisions of Section 1504 of IBC are adopted by reference with the following modifications: 135 pdf_text
14B-15-1504 14B-15-1504 Performance requirements. 134 pdf_text
14B-15-1505 14B-15-1505 Fire classification. The provisions of Section 1505 of IBC are adopted by reference with the following modifications: 136 pdf_text
14B-15-1505 14B-15-1505 Fire classification. 134 pdf_text
14B-15-1506 14B-15-1506 Materials. The provisions of Section 1506 of IBC are adopted by reference with the following modification: 136 pdf_text
14B-15-1507 14B-15-1507 Requirements for roof coverings. 134 pdf_text
14B-15-1507 14B-15-1507 Requirements for roof coverings. The provisions of Section 1507 of IBC are adopted by reference with the following modifications: 136 pdf_text
14B-15-1508 14B-15-1508 Roof insulation. The provisions of Section 1508 of IBC are adopted by reference with the following modification: 137 pdf_text
14B-15-1508 14B-15-1508 Roof insulation. 134 pdf_text
14B-15-1509 14B-15-1509 Radiant barriers installed above deck. The provisions of Section 1509 of IBC are adopted by reference with the following modifications: 138 pdf_text
14B-15-1509 14B-15-1509 Radiant barriers installed above deck. 134 pdf_text
14B-15-1510 14B-15-1510 Unoccupied rooftop structures. The provisions of Section 1510 of IBC are adopted by reference with the following modifications: 138 pdf_text
14B-15-1510 14B-15-1510 Unoccupied rooftop structures. 134 pdf_text
14B-15-1511 14B-15-1511 Reroofing. The provisions of Section 1511 of IBC are not adopted. The following language is adopted as Section 1511: "1511. REROOFING 140 pdf_text
14B-15-1512 14B-15-1512 IBC Section 1512. 134 pdf_text
14B-15-1512 14B-15-1512 IBC Section 1512. The provisions of Section 1512 of IBC are not adopted. 140 pdf_text
14B-15-1513 14B-15-1513 Occupiable rooftops. 134 pdf_text
14B-15-1513 14B-15-1513 Occupiable rooftops. The following language is adopted as a new Section 1513: "1513. OCCUPIABLE ROOFTOPS 140 pdf_text
14B-15-1514 14B-15-1514 Vegetative roofs, roof gardens and landscaped roofs. 134 pdf_text
14B-15-1514 14B-15-1514 Vegetative roofs, roof gardens and landscaped roofs. The following language is adopted as a new Section 1514: "1514. VEGETATIVE ROOFS, ROOF GARDENS AND LANDSCAPED ROOFS 142 pdf_text
14B-15-1515 14B-15-1515 Solar reflectance. 134 pdf_text
14B-15-1515 14B-15-1515 Solar reflectance. The following language is adopted as a new Section 1515: "1515. SOLAR REFLECTANCE 142 pdf_text
14B-15-1516 14B-15-1516 Interior roof edge for shafts and fully enclosed courts. 134 pdf_text
14B-15-1516 14B-15-1516 Interior roof edge for shafts and fully enclosed courts. The following language is adopted as a new Section 1516: “1516. LOW-SLOPED ROOF EDGES AND OPENINGS 143 pdf_text
14B-16-1601 14B-16-1601 General. The provisions of Section 1601 of IBC are adopted by reference without modification. 144 pdf_text
14B-16-1602 14B-16-1602 Notations. The provisions of Section 1602 of IBC are adopted by reference without modification. 144 pdf_text
14B-16-1603 14B-16-1603 Construction documents. 143 pdf_text
14B-16-1603 14B-16-1603 Construction documents. The provisions of Section 1603 of IBC are adopted by reference with the following modifications: 144 pdf_text
14B-16-1604 14B-16-1604 General design requirements. 143 pdf_text
14B-16-1604 14B-16-1604 General design requirements. The provisions of Section 1604 of IBC are adopted by reference with the following modifications: 144 pdf_text
14B-16-1605 14B-16-1605 Load combinations. The provisions of Section 1605 of IBC are adopted by reference with the following modifications: 146 pdf_text
14B-16-1605 14B-16-1605 Load combinations. 143 pdf_text
14B-16-1606 14B-16-1606 Dead loads. 143 pdf_text
14B-16-1606 14B-16-1606 Dead loads. The provisions of Section 1606 of IBC are adopted by reference with the following modification: 146 pdf_text
14B-16-1607 14B-16-1607 Live loads. The provisions of Section 1607 of IBC are adopted by reference with the following modifications: 146 pdf_text
14B-16-1607 14B-16-1607 Live loads. 143 pdf_text
14B-16-1608 14B-16-1608 Snow loads. The provisions of Section 1608 of IBC are adopted by reference with the following modifications: 148 pdf_text
14B-16-1608 14B-16-1608 Snow loads. 143 pdf_text
14B-16-1609 14B-16-1609 Wind loads. The provisions of Section 1609 of IBC are adopted by reference with the following modifications: 148 pdf_text
14B-16-1609 14B-16-1609 Wind loads. 143 pdf_text
14B-16-1610 14B-16-1610 Soil lateral loads. 144 pdf_text
14B-16-1610 14B-16-1610 Soil lateral loads. The provisions of Section 1610 of IBC are adopted by reference with the following modifications: 151 pdf_text
14B-16-1611 14B-16-1611 Rain loads. The provisions of Section 1611 of IBC are adopted by reference with the following modifications: 151 pdf_text
14B-16-1611 14B-16-1611 Rain loads. 144 pdf_text
14B-16-1612 14B-16-1612 Flood design. 144 pdf_text
14B-16-1612 14B-16-1612 Flood design. The provisions of Section 1612 of IBC are not adopted. The following language is adopted as Section 1612: "1612. FLOOD DESIGN. 151 pdf_text
14B-16-1613 14B-16-1613 Earthquake loads. The provisions of Section 1613 of IBC are adopted by reference with the following modifications: 151 pdf_text
14B-16-1613 14B-16-1613 Earthquake loads. 144 pdf_text
14B-16-1614 14B-16-1614 Atmospheric ice loads. The provisions of Section 1614 of IBC are adopted by reference with the following modification: 154 pdf_text
14B-16-1614 14B-16-1614 Atmospheric ice loads. 144 pdf_text
14B-16-1615 14B-16-1615 IBC Section 1615. 144 pdf_text
14B-16-1615 14B-16-1615 IBC Section 1615. The provisions of Section 1615 of IBC are not adopted. 154 pdf_text
14B-16-1616 14B-16-1616 Structural integrity. The provisions of Section 1616 of IBC are adopted by reference without modification. CHAPTER 14B-17 SPECIAL INSPECTIONS AND TESTS 154 pdf_text
14B-16-1616 14B-16-1616 Structural integrity. 144 pdf_text
14B-17-1700 14B-17-1700 Defined terms. Where provisions of Chapter 17 of IBC are adopted by reference, the following terms shall be reset in italic type: "approved "building"; "designated seismic system"; "seismic force-resisting system"; "special inspection"; "special inspector"; "spraye materials"; "structure" and "owner." 154 pdf_text
14B-17-1700 14B-17-1700 Defined terms. 154 pdf_text
14B-17-1701 14B-17-1701 General. The provisions of Section 1701 of IBC are adopted by reference with the following modification: 154 pdf_text
14B-17-1702 14B-17-1702 IBC Section 1702. The provisions of Section 1702 of IBC are not adopted. 154 pdf_text
14B-17-1702 14B-17-1702 IBC Section 1702. 154 pdf_text
14B-17-1703 14B-17-1703 Products, materials and assemblies. 154 pdf_text
14B-17-1703 14B-17-1703 Products, materials and assemblies. 154 pdf_text
14B-17-1704 14B-17-1704 Special inspections and tests, contractor responsibility and structural observation. The provisions of Section 1704 of IBC are adopted by reference with the following modifications: 155 pdf_text
14B-17-1704 14B-17-1704 Special inspections and tests, contractor responsibility and structural observation 154 pdf_text
14B-17-1705 14B-17-1705 Required special inspections and tests. The provisions of Section 1705 of IBC are adopted by reference with the following modifications: 157 pdf_text
14B-17-1705 14B-17-1705 Required special inspections and tests. 154 pdf_text
14B-17-1706 14B-17-1706 Design strength of materials. 154 pdf_text
14B-17-1706 14B-17-1706 Design strength of materials. The provisions of Section 1706 of IBC are adopted by reference with the following modifications: 161 pdf_text
14B-17-1707 14B-17-1707 Alternative test procedure. 154 pdf_text
14B-17-1707 14B-17-1707 Alternative test procedure. The provisions of Section 1707 of IBC are adopted by reference with the following modification: 161 pdf_text
14B-17-1708 14B-17-1708 In-situ load tests. 154 pdf_text
14B-17-1708 14B-17-1708 In-situ load tests. 161 pdf_text
14B-17-1709 14B-17-1709 Preconstruction load tests. The provisions of Section 1709 of IBC are adopted by reference with the following modifications: 162 pdf_text
14B-17-1709 14B-17-1709 Preconstruction load tests. 154 pdf_text
14B-18-1800 14B-18-1800 Defined terms. Where provisions of Chapter 18 of IBC are adopted by reference, the following terms shall be reset in italic type: "deep foun "drilled shaft"; "helical pile"; "light-frame construction"; "micropile"; "plain masonry"; "shallow foundation"; "site" and "so shaft." 162 pdf_text
14B-18-1800 14B-18-1800 Defined terms. 162 pdf_text
14B-18-1802 14B-18-1802 Design basis. The provisions of Section 1802 of IBC are adopted by reference without modification. 163 pdf_text
14B-18-1802 14B-18-1802 Design basis. 162 pdf_text
14B-18-1803 14B-18-1803 Geotechnical investigations. 162 pdf_text
14B-18-1803 14B-18-1803 Geotechnical investigations. The provisions of Section 1803 of IBC are adopted by reference with the following modifications: 163 pdf_text
14B-18-1804 14B-18-1804 Excavation, grading and fill. The provisions of Section 1804 of IBC are adopted by reference with the following modifications: 164 pdf_text
14B-18-1804 14B-18-1804 Excavation, grading and fill. 162 pdf_text
14B-18-1805 14B-18-1805 Dampproofing and waterproofing. 162 pdf_text
14B-18-1805 14B-18-1805 Dampproofing and waterproofing. The provisions of Section 1805 of IBC are adopted by reference with the following modifications: 165 pdf_text
14B-18-1806 14B-18-1806 Presumptive load-bearing values of soils. 162 pdf_text
14B-18-1806 14B-18-1806 Presumptive load-bearing values of soils. The provisions of Section 1806 of IBC are adopted by reference with the following modifications: 165 pdf_text
14B-18-1807 14B-18-1807 Foundation walls, retaining walls and embedded posts and poles. The provisions of Section 1807 of IBC are adopted by reference with the following modifications: 168 pdf_text
14B-18-1807 14B-18-1807 Foundation walls, retaining walls and embedded posts and poles. 162 pdf_text
14B-18-1808 14B-18-1808 Foundations. The provisions of Section 1808 of IBC are adopted by reference with the following modifications: 168 pdf_text
14B-18-1809 14B-18-1809 Shallow foundations. 162 pdf_text
14B-18-1809 14B-18-1809 Shallow foundations. The provisions of Section 1809 of IBC are adopted by reference with the following modifications: 169 pdf_text
14B-18-1810 14B-18-1810 Deep foundations. 162 pdf_text
14B-18-1810 14B-18-1810 Deep foundations. The provisions of Section 1810 of IBC are adopted by reference with the following modifications: 170 pdf_text
14B-19-1901 14B-19-1901 General. The provisions of Section 1901 of IBC are adopted by reference with the following modifications: 176 pdf_text
14B-19-1902 14B-19-1902 Definitions. The provisions of Section 1902 of IBC are adopted by reference without modification. 176 pdf_text
14B-19-1903 14B-19-1903 Specifications for tests and materials. The provisions of Section 1903 of IBC are adopted by reference without modification. 177 pdf_text
14B-19-1903 14B-19-1903 Specifications for tests and materials. 176 pdf_text
14B-19-1904 14B-19-1904 Durability requirements. 176 pdf_text
14B-19-1904 14B-19-1904 Durability requirements. The provisions of Section 1904 of IBC are adopted by reference with the following modification: 177 pdf_text
14B-19-1905 14B-19-1905 Modifications to ACI 318. 176 pdf_text
14B-19-1905 14B-19-1905 Modifications to ACI 318. The provisions of Section 1905 of IBC are adopted by reference with the following modifications: 177 pdf_text
14B-19-1906 14B-19-1906 Structural plain concrete. 176 pdf_text
14B-19-1906 14B-19-1906 Structural plain concrete. The provisions of Section 1906 of IBC are adopted by reference with the following modification: 177 pdf_text
14B-19-1907 14B-19-1907 Minimum slab provisions. 176 pdf_text
14B-19-1907 14B-19-1907 Minimum slab provisions. The provisions of Section 1907 of IBC are adopted by reference with the following modifications: 177 pdf_text
14B-19-1908 14B-19-1908 Shotcrete. The provisions of Section 1908 of IBC are adopted by reference with the following modifications: 177 pdf_text
14B-2-201 14B-2-201 General. The provisions of Section 201 of IBC are not adopted. The following language is adopted as Section 201: "201. GENERAL 3 pdf_text
14B-2-202 14B-2-202 Definitions. The provisions of Section 202 of IBC are adopted by reference with the following modifications: 3 pdf_text
14B-2-203 14B-2-203 Measurements. The following language is adopted as a new Section 203: "203. MEASUREMENTS 17 pdf_text
14B-20-2001 14B-20-2001 General. The provisions of Section 2001 of IBC are adopted by reference without modification. 177 pdf_text
14B-20-2002 14B-20-2002 Materials. The provisions of Section 2002 of IBC are adopted by reference without modification. 177 pdf_text
14B-21-2100 14B-21-2100 Defined terms. 178 pdf_text
14B-21-2100 14B-21-2100 Defined terms. Where provisions of Chapter 21 of IBC are adopted by reference, the following terms shall be reset in italic type: "AAC mas "adhered masonry veneer"; "bed joint"; "chimney"; "fireplace"; "fireplace throat"; "fire-resistance rating"; "hollow masonry "masonry unit"; "mortar"; "solid masonry unit"; "stone masonry"; "structural clay tile"; "surface-bonding mortar" and "wyth 178 pdf_text
14B-21-2101 14B-21-2101 General. The provisions of Section 2101 of IBC are adopted by reference with the following modification: 178 pdf_text
14B-21-2102 14B-21-2102 Notations. The provisions of Section 2102 of IBC are adopted by reference without modification. 178 pdf_text
14B-21-2103 14B-21-2103 Masonry construction materials. The provisions of Section 2103 of IBC are adopted by reference with the following modifications: 178 pdf_text
14B-21-2103 14B-21-2103 Masonry construction materials. 178 pdf_text
14B-21-2104 14B-21-2104 Construction. The provisions of Section 2104 of IBC are adopted by reference with the following modification: 179 pdf_text
14B-21-2105 14B-21-2105 Quality assurance. The provisions of Section 2105 of IBC are adopted by reference with the following modification: 179 pdf_text
14B-21-2105 14B-21-2105 Quality assurance. 178 pdf_text
14B-21-2106 14B-21-2106 Seismic design. 178 pdf_text
14B-21-2106 14B-21-2106 Seismic design. The provisions of Section 2106 of IBC are adopted by reference without modification. 179 pdf_text
14B-21-2107 14B-21-2107 Allowable stress design. 178 pdf_text
14B-21-2107 14B-21-2107 Allowable stress design. The provisions of Section 2107 of IBC are adopted by reference without modification. 179 pdf_text
14B-21-2108 14B-21-2108 Strength design of masonry. The provisions of Section 2108 of IBC are adopted by reference without modification. 179 pdf_text
14B-21-2108 14B-21-2108 Strength design of masonry. 178 pdf_text
14B-21-2109 14B-21-2109 IBC Section 2109. 178 pdf_text
14B-21-2109 14B-21-2109 IBC Section 2109. The provisions of Section 2109 of IBC are not adopted. 179 pdf_text
14B-21-2110 14B-21-2110 Glass unit masonry. 178 pdf_text
14B-21-2110 14B-21-2110 Glass unit masonry. The provisions of Section 2110 of IBC are adopted by reference with the following modification: 179 pdf_text
14B-21-2111 14B-21-2111 Masonry fireplaces. 178 pdf_text
14B-21-2111 14B-21-2111 Masonry fireplaces. The provisions of Section 2111 of IBC are adopted by reference with the following modifications: 179 pdf_text
14B-21-2112 14B-21-2112 Masonry heaters. 178 pdf_text
14B-21-2112 14B-21-2112 Masonry heaters. The provisions of Section 2112 of IBC are adopted by reference with the following modification: 179 pdf_text
14B-21-2113 14B-21-2113 Masonry chimneys. 179 pdf_text
14B-21-2113 14B-21-2113 Masonry chimneys. 178 pdf_text
14B-21-2114 14B-21-2114 Dry-stack masonry. The provisions of Section 2114 of IBC are adopted by reference without modification. CHAPTER 14B-22 STEEL 180 pdf_text
14B-21-2114 14B-21-2114 Dry-stack masonry. 178 pdf_text
14B-22-2200 14B-22-2200 Defined terms. 180 pdf_text
14B-22-2200 14B-22-2200 Defined terms. 180 pdf_text
14B-22-2201 14B-22-2201 General. The provisions of Section 2201 of IBC are adopted by reference without modification. 181 pdf_text
14B-22-2202 14B-22-2202 Identification of steel for structural purposes. 180 pdf_text
14B-22-2202 14B-22-2202 Identification of steel for structural purposes. The provisions of Section 2202 of IBC are adopted by reference without modification. 181 pdf_text
14B-22-2203 14B-22-2203 Protection of steel for structural purposes. The provisions of Section 2203 of IBC are adopted by reference without modification. 181 pdf_text
14B-22-2203 14B-22-2203 Protection of steel for structural purposes. 180 pdf_text
14B-22-2204 14B-22-2204 Connections. The provisions of Section 2204 of IBC are adopted by reference with the following modification: 181 pdf_text
14B-22-2205 14B-22-2205 Structural steel. The provisions of Section 2205 of IBC are adopted by reference with the following modifications: 181 pdf_text
14B-22-2205 14B-22-2205 Structural steel. 180 pdf_text
14B-22-2206 14B-22-2206 Composite structural steel and concrete structures. The provisions of Section 2206 of IBC are adopted by reference without modification. 181 pdf_text
14B-22-2206 14B-22-2206 Composite structural steel and concrete structures. 180 pdf_text
14B-22-2207 14B-22-2207 Steel joists. 180 pdf_text
14B-22-2207 14B-22-2207 Steel joists. The provisions of Section 2207 of IBC are adopted by reference with the following modifications: 181 pdf_text
14B-22-2208 14B-22-2208 Steel cable structures. 180 pdf_text
14B-22-2208 14B-22-2208 Steel cable structures. The provisions of Section 2208 of IBC are adopted by reference without modification. 181 pdf_text
14B-22-2209 14B-22-2209 Steel storage racks. 180 pdf_text
14B-22-2209 14B-22-2209 Steel storage racks. The provisions of Section 2209 of IBC are adopted by reference without modification. 181 pdf_text
14B-22-2210 14B-22-2210 Cold-formed steel. The provisions of Section 2210 of IBC are adopted by reference without modification. 181 pdf_text
14B-22-2210 14B-22-2210 Cold-formed steel. 180 pdf_text
14B-22-2211 14B-22-2211 Cold-formed steel light-frame construction. 180 pdf_text
14B-22-2211 14B-22-2211 Cold-formed steel light-frame construction. The provisions of Section 2211 of IBC are adopted by reference with the following modifications: 181 pdf_text
14B-22-2212 14B-22-2212 Cast iron. 180 pdf_text
14B-22-2212 14B-22-2212 Cast iron. The following language is adopted as a new Section 2212: "2212. CAST IRON 182 pdf_text
14B-23-2300 14B-23-2300 Defined terms. Where provisions of Chapter 23 of IBC are adopted by reference, the following terms shall be reset in italic type: "accreditat "braced wall line"; "braced wall panel"; "cripple wall"; "diaphragm"; "drag strut"; engineered wood rim board"; "fiberboard" "hardboard"; "hold-down"; "naturally durable wood"; "particleboard"; "performance category"; "prefabricated wood I-joist"; category"; "structural composite lumber"; "tie-down" and "wood structural panel." 182 pdf_text
14B-23-2300 14B-23-2300 Defined terms. 182 pdf_text
14B-23-2302 14B-23-2302 Design requirements. The provisions of Section 2302 of IBC are adopted by reference without modification. 183 pdf_text
14B-23-2302 14B-23-2302 Design requirements. 182 pdf_text
14B-23-2303 14B-23-2303 Minimum standards and quality. 182 pdf_text
14B-23-2303 14B-23-2303 Minimum standards and quality. The provisions of Section 2303 of IBC are adopted by reference with the following modifications: 183 pdf_text
14B-23-2304 14B-23-2304 General construction requirements. 182 pdf_text
14B-23-2304 14B-23-2304 General construction requirements. The provisions of Section 2304 of IBC are adopted by reference with the following modifications: 184 pdf_text
14B-23-2305 14B-23-2305 General design requirements for lateral force-resisting systems. 182 pdf_text
14B-23-2305 14B-23-2305 General design requirements for lateral force-resisting systems. The provisions of Section 2305 of IBC are adopted by reference with the following modification: 185 pdf_text
14B-23-2306 14B-23-2306 Allowable stress design. 182 pdf_text
14B-23-2306 14B-23-2306 Allowable stress design. The provisions of Section 2306 of IBC are adopted by reference with the following modifications: 185 pdf_text
14B-23-2307 14B-23-2307 Load and resistance factor design. The provisions of Section 2307 of IBC are adopted by reference without modification. 185 pdf_text
14B-23-2307 14B-23-2307 Load and resistance factor design. 182 pdf_text
14B-23-2308 14B-23-2308 Conventional light-frame construction. 182 pdf_text
14B-23-2308 14B-23-2308 Conventional light-frame construction. The provisions of Section 2308 of IBC are adopted by reference with the following modifications: 185 pdf_text
14B-23-2309 14B-23-2309 Wood frame construction manual. The provisions of Section 2309 of IBC are adopted by reference without modification. CHAPTER 14B-24 GLASS AND GLAZING 187 pdf_text
14B-23-2309 14B-23-2309 Wood frame construction manual. 182 pdf_text
14B-24-2400 14B-24-2400 Defined terms. 187 pdf_text
14B-24-2400 14B-24-2400 Defined terms. Where provisions of Chapter 24 of IBC are adopted by reference, the following terms shall be reset in italic type: "decorativ "unit skylight." 187 pdf_text
14B-24-2401 14B-24-2401 General. The provisions of Section 2401 of IBC are adopted by reference without modification. 187 pdf_text
14B-24-2402 14B-24-2402 IBC Section 2402. 187 pdf_text
14B-24-2402 14B-24-2402 IBC Section 2402. The provisions of Section 2402 of IBC are not adopted. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 85) 187 pdf_text
14B-24-2403 14B-24-2403 General requirements for glass. 187 pdf_text
14B-24-2403 14B-24-2403 General requirements for glass. The provisions of Section 2403 of IBC are adopted by reference with the following modifications: 187 pdf_text
14B-24-2404 14B-24-2404 Wind, snow, seismic and dead loads on glass. The provisions of Section 2404 of IBC are adopted by reference without modification. 187 pdf_text
14B-24-2404 14B-24-2404 Wind, snow, seismic and dead loads on glass. 187 pdf_text
14B-24-2405 14B-24-2405 Sloped glazing and skylights. 187 pdf_text
14B-24-2405 14B-24-2405 Sloped glazing and skylights. The provisions of Section 2405 of IBC are adopted by reference with the following modifications: 187 pdf_text
14B-24-2406 14B-24-2406 Safety glazing. The provisions of Section 2406 of IBC are adopted by reference with the following modifications: 188 pdf_text
14B-24-2406 14B-24-2406 Safety glazing. 187 pdf_text
14B-24-2407 14B-24-2407 Glass in guards. 187 pdf_text
14B-24-2407 14B-24-2407 Glass in guards. The provisions of Section 2407 of IBC are adopted by reference with the following modifications: 188 pdf_text
14B-24-2408 14B-24-2408 Glazing in athletic facilities. The provisions of Section 2408 of IBC are adopted by reference without modification. 189 pdf_text
14B-24-2408 14B-24-2408 Glazing in athletic facilities. 187 pdf_text
14B-24-2409 14B-24-2409 Glass in walkways, elevator hoistways and elevator cars. The provisions of Section 2409 of IBC are adopted by reference with the following modifications: 189 pdf_text
14B-24-2409 14B-24-2409 Glass in walkways, elevator hoistways and elevator cars. 187 pdf_text
14B-25-2500 14B-25-2500 Defined terms. Where provisions of Chapter 25 of IBC are adopted by reference, the following terms shall be reset in italic type: "cement pl "exterior surfaces"; "gypsum board"; "gypsum panel products"; "gypsum plaster"; "gypsum veneer plaster"; "interior surface backing." 190 pdf_text
14B-25-2500 14B-25-2500 Defined terms. 189 pdf_text
14B-25-2501 14B-25-2501 General. The provisions of Section 2501 of IBC are adopted by reference with the following modification: 190 pdf_text
14B-25-2502 14B-25-2502 Performance. The provisions of Section 2502 of IBC are adopted by reference with the following modification: 190 pdf_text
14B-25-2503 14B-25-2503 IBC Section 2503. 189 pdf_text
14B-25-2503 14B-25-2503 IBC Section 2503. The provisions of Section 2503 of IBC are not adopted. 190 pdf_text
14B-25-2504 14B-25-2504 Vertical and horizontal assemblies. 189 pdf_text
14B-25-2504 14B-25-2504 Vertical and horizontal assemblies. The provisions of Section 2504 of IBC are adopted by reference without modification. 190 pdf_text
14B-25-2505 14B-25-2505 Shear wall construction. The provisions of Section 2505 of IBC are adopted by reference without modification. 190 pdf_text
14B-25-2505 14B-25-2505 Shear wall construction. 189 pdf_text
14B-25-2506 14B-25-2506 Gypsum board and gypsum panel product materials. 189 pdf_text
14B-25-2506 14B-25-2506 Gypsum board and gypsum panel product materials. The provisions of Section 2506 of IBC are adopted by reference with the following modifications: 190 pdf_text
14B-25-2507 14B-25-2507 Lathing and plastering. The provisions of Section 2507 of IBC are adopted by reference without modification. 190 pdf_text
14B-25-2507 14B-25-2507 Lathing and plastering. 189 pdf_text
14B-25-2508 14B-25-2508 Gypsum construction. 189 pdf_text
14B-25-2508 14B-25-2508 Gypsum construction. The provisions of Section 2508 of IBC are adopted by reference with the following modifications: 190 pdf_text
14B-25-2509 14B-25-2509 Wet areas. 190 pdf_text
14B-25-2509 14B-25-2509 Wet areas. 189 pdf_text
14B-25-2510 14B-25-2510 Lathing and furring for cement plaster (stucco). The provisions of Section 2510 of IBC are adopted by reference with the following modifications: 191 pdf_text
14B-25-2510 14B-25-2510 Lathing and furring for cement plaster (stucco). 189 pdf_text
14B-25-2511 14B-25-2511 Interior plaster. The provisions of Section 2511 of IBC are adopted by reference with the following modifications: 191 pdf_text
14B-25-2511 14B-25-2511 Interior plaster. 189 pdf_text
14B-25-2512 14B-25-2512 Exterior plaster. 189 pdf_text
14B-25-2512 14B-25-2512 Exterior plaster. The provisions of Section 2512 of IBC are adopted by reference with the following modifications: 191 pdf_text
14B-25-2513 14B-25-2513 Exposed aggregate plaster. The provisions of Section 2513 of IBC are adopted by reference with the following modification: 191 pdf_text
14B-25-2513 14B-25-2513 Exposed aggregate plaster. 189 pdf_text
14B-25-2514 14B-25-2514 Reinforced gypsum concrete. The provisions of Section 2514 of IBC are adopted by reference without modification. CHAPTER 14B-26 PLASTIC 191 pdf_text
14B-25-2514 14B-25-2514 Reinforced gypsum concrete. 189 pdf_text
14B-26-2601 14B-26-2601 General. The provisions of Section 2601 of IBC are adopted by reference with the following modification: 192 pdf_text
14B-26-2602 14B-26-2602 Finish and trim. 191 pdf_text
14B-26-2602 14B-26-2602 Finish and trim. The provisions of Section 2602 of IBC are adopted by reference without modification. 192 pdf_text
14B-26-2603 14B-26-2603 Foam plastic insulation. The provisions of Section 2603 of IBC are adopted by reference with the following modifications: 192 pdf_text
14B-26-2603 14B-26-2603 Foam plastic insulation. 192 pdf_text
14B-26-2604 14B-26-2604 Interior finish and trim. 192 pdf_text
14B-26-2604 14B-26-2604 Interior finish and trim. The provisions of Section 2604 of IBC are adopted by reference with the following modification: 194 pdf_text
14B-26-2605 14B-26-2605 Plastic veneer. 192 pdf_text
14B-26-2605 14B-26-2605 Plastic veneer. The provisions of Section 2605 of IBC are adopted by reference with the following modification: 194 pdf_text
14B-26-2606 14B-26-2606 Light-transmitting plastics. The provisions of Section 2606 of IBC are adopted by reference with the following modifications: 194 pdf_text
14B-26-2606 14B-26-2606 Light-transmitting plastics. 192 pdf_text
14B-26-2607 14B-26-2607 Light-transmitting plastic wall panels. 192 pdf_text
14B-26-2607 14B-26-2607 Light-transmitting plastic wall panels. The provisions of Section 2607 of IBC are adopted by reference with the following modifications: 194 pdf_text
14B-26-2608 14B-26-2608 Light-transmitting plastic glazing. The provisions of Section 2608 of IBC are adopted by reference with the following modifications: 195 pdf_text
14B-26-2608 14B-26-2608 Light-transmitting plastic glazing. 192 pdf_text
14B-26-2609 14B-26-2609 Light-transmitting plastic roof panels. 192 pdf_text
14B-26-2609 14B-26-2609 Light-transmitting plastic roof panels. The provisions of Section 2609 of IBC are adopted by reference with the following modifications: 195 pdf_text
14B-26-2610 14B-26-2610 Light-transmitting plastic skylight glazing. The provisions of Section 2610 of IBC are adopted by reference with the following modifications: 195 pdf_text
14B-26-2610 14B-26-2610 Light-transmitting plastic skylight glazing. 192 pdf_text
14B-26-2611 14B-26-2611 Light-transmitting plastic interior signs. 192 pdf_text
14B-26-2611 14B-26-2611 Light-transmitting plastic interior signs. The provisions of Section 2611 of IBC are adopted by reference with the following modification: 195 pdf_text
14B-26-2612 14B-26-2612 Plastic composites. 192 pdf_text
14B-26-2612 14B-26-2612 Plastic composites. The provisions of Section 2612 of IBC are adopted by reference with the following modification: 195 pdf_text
14B-26-2613 14B-26-2613 Fiber-reinforced polymer. The provisions of Section 2613 of IBC are adopted by reference with the following modification: 195 pdf_text
14B-26-2613 14B-26-2613 Fiber-reinforced polymer. 192 pdf_text
14B-26-2614 14B-26-2614 IBC Section 2614. 192 pdf_text
14B-26-2614 14B-26-2614 IBC Section 2614. The provisions of Section 2614 of IBC are not adopted. CHAPTER 14B-27 ELECTRICAL 196 pdf_text
14B-27-2701 14B-27-2701 General. The provisions of Section 2701 of IBC are adopted by reference without modification. 196 pdf_text
14B-27-2702 14B-27-2702 Emergency and standby power systems. 196 pdf_text
14B-27-2702 14B-27-2702 Emergency and standby power systems. The provisions of Section 2702 of IBC are adopted by reference with the following modifications: 196 pdf_text
14B-28-2801 14B-28-2801 General. The provisions of Section 2801 of IBC are adopted by reference without modification. CHAPTER 14B-29 PLUMBING SYSTEMS 197 pdf_text
14B-29-2900 14B-29-2900 Chapter 29. The provisions of Chapter 29 of IBC are not adopted. The following language is adopted as Chapter 29: "2901 GENERAL 197 pdf_text
14B-3-300 14B-3-300 Defined terms. Where provisions of Chapter 3 of IBC are adopted by reference, the following terms shall be reset in italic type: "building" a 18 pdf_text
14B-3-300 14B-3-300 Defined terms. 18 pdf_text
14B-3-301 14B-3-301 General. The provisions of Section 301 of IBC are adopted by reference with the following modification: 18 pdf_text
14B-3-302 14B-3-302 Occupancy classification and use designation. 18 pdf_text
14B-3-302 14B-3-302 Occupancy classification and use designation. The provisions of Section 302 of IBC are adopted by reference with the following modifications: 19 pdf_text
14B-3-303 14B-3-303 Assembly Group A. The provisions of Section 303 of IBC are adopted by reference with the following modifications: 19 pdf_text
14B-3-303 14B-3-303 Assembly Group A. 18 pdf_text
14B-3-304 14B-3-304 Business Group B. The provisions of Section 304 of IBC are adopted by reference with the following modifications: 19 pdf_text
14B-3-304 14B-3-304 Business Group B. 18 pdf_text
14B-3-305 14B-3-305 Educational Group E. The provisions of Section 305 of IBC are not adopted. The following language is adopted as Section 305: "305. EDUCATIONAL GROUP E 19 pdf_text
14B-3-305 14B-3-305 Educational Group E. 18 pdf_text
14B-3-306 14B-3-306 Factory Group F. 18 pdf_text
14B-3-306 14B-3-306 Factory Group F. The provisions of Section 306 of IBC are adopted by reference with the following modifications: 20 pdf_text
14B-3-307 14B-3-307 High-hazard Group H. 18 pdf_text
14B-3-307 14B-3-307 High-hazard Group H. The provisions of Section 307 of IBC are adopted by reference with the following modifications: 20 pdf_text
14B-3-308 14B-3-308 Institutional Group I. 18 pdf_text
14B-3-308 14B-3-308 Institutional Group I. The provisions of Section 308 of IBC are adopted by reference with the following modifications: 21 pdf_text
14B-3-309 14B-3-309 Mercantile Group M. The provisions of Section 309 of IBC are adopted by reference without modification. 21 pdf_text
14B-3-309 14B-3-309 Mercantile Group M. 18 pdf_text
14B-3-310 14B-3-310 Residential Group R. 18 pdf_text
14B-3-310 14B-3-310 Residential Group R. The provisions of Section 310 of IBC are not adopted. The following language is adopted as Section 310: 21 pdf_text
14B-3-311 14B-3-311 Storage Group S. 18 pdf_text
14B-3-311 14B-3-311 Storage Group S. The provisions of Section 311 of IBC are adopted by reference with the following modifications: 23 pdf_text
14B-3-312 14B-3-312 Utility and Miscellaneous Group U. 18 pdf_text
14B-3-312 14B-3-312 Utility and Miscellaneous Group U. The provisions of Section 312 of IBC are adopted by reference with the following modifications: 23 pdf_text
14B-30-3001 14B-30-3001 General. The provisions of Section 3001 of IBC are adopted by reference with the following modifications: 197 pdf_text
14B-30-3002 14B-30-3002 Hoistway enclosures. The provisions of Section 3002 of IBC are adopted by reference with the following modifications: 198 pdf_text
14B-30-3002 14B-30-3002 Hoistway enclosures. 197 pdf_text
14B-30-3003 14B-30-3003 Elevator emergency operations. 197 pdf_text
14B-30-3003 14B-30-3003 Elevator emergency operations. The provisions of Section 3003 of IBC are adopted by reference with the following modifications: 199 pdf_text
14B-30-3004 14B-30-3004 Other conveyance devices. The provisions of Section 3004 of IBC are adopted by reference with the following modifications: 199 pdf_text
14B-30-3004 14B-30-3004 Other conveyance devices. 197 pdf_text
14B-30-3005 14B-30-3005 Machine rooms. 197 pdf_text
14B-30-3005 14B-30-3005 Machine rooms. The provisions of Section 3005 of IBC are adopted by reference with the following modifications: 199 pdf_text
14B-30-3006 14B-30-3006 IBC Section 3006. 197 pdf_text
14B-30-3006 14B-30-3006 IBC Section 3006. 199 pdf_text
14B-30-3007 14B-30-3007 Fire service access elevator. 197 pdf_text
14B-30-3007 14B-30-3007 Fire service access elevator. The provisions of Section 3007 of IBC are adopted by reference with the following modifications: 200 pdf_text
14B-30-3008 14B-30-3008 IBC Section 3008. 197 pdf_text
14B-30-3008 14B-30-3008 IBC Section 3008. The provisions of Section 3008 of IBC are not adopted. CHAPTER 14B-31 SPECIAL CONSTRUCTION 200 pdf_text
14B-31-3102 14B-31-3102 Membrane structures. 200 pdf_text
14B-31-3102 14B-31-3102 Membrane structures. The provisions of Section 3102 of IBC are adopted by reference with the following modifications: 201 pdf_text
14B-31-3103 14B-31-3103 Temporary Structures. The provisions of Section 3103 of IBC are not adopted. The following is adopted as Section 3103: "3103.1 General. The provisions of Sections 3103.1 through 3103.3 shall apply to temporary structures. Structures erected on the sam than 180 days within a 12-month period shall comply with provisions of this code applicable to permanent structures Exceptions: 201 pdf_text
14B-31-3103 14B-31-3103 Temporary structures. 200 pdf_text
14B-31-3104 14B-31-3104 Pedestrian walkways and tunnels. The provisions of Section 3104 of IBC are adopted by reference with the following modifications: 203 pdf_text
14B-31-3104 14B-31-3104 Pedestrian walkways and tunnels. 200 pdf_text
14B-31-3105 14B-31-3105 Awnings and canopies. The provisions of Section 3105 of IBC are adopted by reference with the following modifications: 203 pdf_text
14B-31-3105 14B-31-3105 Awnings and canopies. 200 pdf_text
14B-31-3107 14B-31-3107 IBC Section 3107. 200 pdf_text
14B-31-3107 14B-31-3107 IBC Section 3107. The provisions of Section 3107 of IBC are not adopted. 204 pdf_text
14B-31-3108 14B-31-3108 Telecommunication and broadcast towers. 200 pdf_text
14B-31-3108 14B-31-3108 Telecommunication and broadcast towers. The provisions of Section 3108 of IBC are adopted by reference without modification. 204 pdf_text
14B-31-3109 14B-31-3109 Swimming pools, spas and hot tubs. The provisions of Section 3109 of IBC are adopted by reference with the following modification: 204 pdf_text
14B-31-3109 14B-31-3109 Swimming pools, spas and hot tubs. 200 pdf_text
14B-31-3110 14B-31-3110 Automatic vehicular gates. 200 pdf_text
14B-31-3110 14B-31-3110 Automatic vehicular gates. The provisions of Section 3110 of IBC are adopted by reference without modification. 204 pdf_text
14B-31-3111 14B-31-3111 Solar energy systems. The provisions of Section 3111 of IBC are adopted by reference with the following modification: 204 pdf_text
14B-31-3111 14B-31-3111 Solar energy systems. 200 pdf_text
14B-31-3112 14B-31-3112 Greenhouses. The provisions of Section 3112 of IBC are adopted by reference without modification. 204 pdf_text
14B-31-3113 14B-31-3113 IBC Section 3113. 200 pdf_text
14B-31-3113 14B-31-3113 IBC Section 3113. The provisions of Section 3113 of IBC are not adopted. 204 pdf_text
14B-31-3114 14B-31-3114 Fences. The following language is adopted as a new Section 3114: "3114. FENCES 204 pdf_text
14B-32-3201 14B-32-3201 General. The provisions of Section 3201 of IBC are adopted by reference with the following modifications: 205 pdf_text
14B-33-3301 14B-33-3301 General. The provisions of Section 3301 of IBC are adopted by reference with the following modifications: 207 pdf_text
14B-33-3302 14B-33-3302 Construction safeguards. 207 pdf_text
14B-33-3302 14B-33-3302 Construction safeguards. The provisions of Section 3302 of IBC are adopted by reference with the following modifications: 208 pdf_text
14B-33-3303 14B-33-3303 Demolition. The provisions of Section 3303 of IBC are adopted by reference with the following modifications: 208 pdf_text
14B-33-3304 14B-33-3304 Site work. 208 pdf_text
14B-33-3304 14B-33-3304 Site work. 207 pdf_text
14B-33-3305 14B-33-3305 Sanitary. The provisions of Section 3305 of IBC are adopted by reference with the following modification: 209 pdf_text
14B-33-3306 14B-33-3306 Protection of pedestrians. 207 pdf_text
14B-33-3306 14B-33-3306 Protection of pedestrians. The provisions of Section 3306 of IBC are adopted by reference with the following modifications: 209 pdf_text
14B-33-3307 14B-33-3307 Protection of adjoining property. 207 pdf_text
14B-33-3307 14B-33-3307 Protection of adjoining property. The provisions of Section 3307 of IBC are adopted by reference with the following modifications: 209 pdf_text
14B-33-3308 14B-33-3308 Temporary use of streets, alleys and public property. 207 pdf_text
14B-33-3308 14B-33-3308 Temporary use of streets, alleys and public property. The provisions of Section 3308 of IBC are adopted by reference with the following modifications: 209 pdf_text
14B-33-3309 14B-33-3309 Fire extinguishers. The provisions of Section 3309 of IBC are adopted by reference with the following modification: 210 pdf_text
14B-33-3309 14B-33-3309 Fire extinguishers. 207 pdf_text
14B-33-3310 14B-33-3310 Means of egress. 207 pdf_text
14B-33-3310 14B-33-3310 Means of egress. The provisions of Section 3310 of IBC are adopted by reference with the following modification: 210 pdf_text
14B-33-3311 14B-33-3311 Standpipes. The provisions of Section 3311 of IBC are adopted by reference without modification. 210 pdf_text
14B-33-3312 14B-33-3312 Automatic sprinkler system. The provisions of Section 3312 of IBC are adopted by reference with the following modification: 210 pdf_text
14B-33-3312 14B-33-3312 Automatic sprinkler system. 207 pdf_text
14B-33-3313 14B-33-3313 IBC Section 3313. The provisions of Section 3313 of IBC are not adopted. 210 pdf_text
14B-33-3313 14B-33-3313 IBC Section 3313. 207 pdf_text
14B-33-3314 14B-33-3314 Owner’s responsibility for fire protection. 207 pdf_text
14B-33-3314 14B-33-3314 Owner’s responsibility for fire protection. The provisions of Section 3314 of IBC are not adopted. The following language is adopted as Section 3314: "3314. OWNER’S RESPONSIBILITY FOR FIRE PROTECTION 210 pdf_text
14B-33-3315 14B-33-3315 Temporary heating equipment. The following language is adopted as a new Section 3315: "3315. TEMPORARY HEATING EQUIPMENT 211 pdf_text
14B-33-3315 14B-33-3315 Temporary heating equipment. 207 pdf_text
14B-33-3316 14B-33-3316 Precautions against fire. 207 pdf_text
14B-33-3316 14B-33-3316 Precautions against fire. The following language is adopted as a new Section 3316: 211 pdf_text
14B-33-3317 14B-33-3317 Flammable and combustible liquids. The following language is adopted as a new Section 3317: "3317. FLAMMABLE AND COMBUSTIBLE LIQUIDS 213 pdf_text
14B-33-3317 14B-33-3317 Flammable and combustible liquids. 207 pdf_text
14B-33-3318 14B-33-3318 Flammable gases. 207 pdf_text
14B-33-3318 14B-33-3318 Flammable gases. The following language is adopted as a new Section 3318: "3318. FLAMMABLE GASES 213 pdf_text
14B-33-3319 14B-33-3319 Explosive materials. 207 pdf_text
14B-33-3319 14B-33-3319 Explosive materials. The following language is adopted as a new Section 3319: "3319. EXPLOSIVE MATERIALS 213 pdf_text
14B-33-3320 14B-33-3320 Fire reporting. The following language is adopted as a new Section 3320: "3320. FIRE REPORTING 214 pdf_text
14B-33-3320 14B-33-3320 Fire reporting. 207 pdf_text
14B-33-3321 14B-33-3321 Motorized construction equipment. 207 pdf_text
14B-33-3321 14B-33-3321 Motorized construction equipment. The following language is adopted as a new Section 3321: "3321. MOTORIZED CONSTRUCTION EQUIPMENT 214 pdf_text
14B-33-3322 14B-33-3322 Safeguarding roofing operations. The following language is adopted as a new Section 3322: "3322. SAFEGUARDING ROOFING OPERATIONS 214 pdf_text
14B-33-3322 14B-33-3322 Safeguarding roofing operations. 207 pdf_text
14B-33-3323 14B-33-3323 Scaffolding. The following language is adopted as a new Section 3323: "3323. SCAFFOLDING 214 pdf_text
14B-33-3324 14B-33-3324 Construction site cleanliness. The following language is adopted as a new Section 3324: "3324. CONSTRUCTION SITE CLEANLINESS 215 pdf_text
14B-33-3324 14B-33-3324 Construction site cleanliness. 207 pdf_text
14B-35-3500 14B-35-3500 Chapter 35. The provisions of Chapter 35 of IBC are adopted by reference with the following modifications: 216 pdf_text
14B-36-3600 14B-36-3600 Appendices not adopted. 217 pdf_text
14B-36-3600 14B-36-3600 Appendices not adopted. The provisions of Appendices A, B, C, F, G, H, I, J, K, L, M, and N of IBC are not adopted. 217 pdf_text
14B-36-3604 14B-36-3604 Appendix D – Fire limits. The provisions of Appendix D of IBC are adopted by reference with the following modifications: 217 pdf_text
14B-36-3604 14B-36-3604 Appendix D – Fire limits. 217 pdf_text
14B-36-3605 14B-36-3605 Appendix E – Supplementary accessibility requirements. The provisions of Appendix E of IBC are adopted by reference with the following modifications: 219 pdf_text
14B-36-3605 14B-36-3605 Appendix E – Supplementary accessibility requirements. 217 pdf_text
14B-36-3619 14B-36-3619 Appendix S – Optional smoke control systems. 217 pdf_text
14B-36-3619 14B-36-3619 Appendix S – Optional smoke control systems. The following language is adopted as a new Appendix S: "APPENDIX S. OPTIONAL SMOKE CONTROL SYSTEMS S101. GENERAL S101.1 Scope and purpose. This appendix applies to mechanical or passive smoke control systems where they are installed. Where smoke contro proposed as an alternative to other requirements of this code, they shall be approved by the Committee on Standards accordance with Section 1004 of the Chicago Construction Codes Administrative Provisions. The purpose of this ap establish minimum requirements for the design, installation and acceptance testing of smoke control systems that are provide a tenable environment for the evacuation or relocation of occupants. These provisions are not intended for th of contents, the timely restoration of operations or for assistance in fire suppression or overhaul activities. Smoke co regulated by this appendix serve a different purpose than the smoke- and heat-removal provisions found in Section 9 Mechanical smoke control systems shall not be considered exhaust systems under Chapter 5 of the Chicago Mechani S101.2 General design requirements. Buildings, structures or parts thereof required by this code to have a smoke control system or systems shall have suc designed in accordance with the applicable requirements of Section S101 and the generally accepted and well-establi of engineering relevant to the design. The construction documents shall include sufficient information and 220 pdf_text
14B-36-3619 (cont. 2) detail to a describe the elements of the design necessary for the proper implementation of the smoke control systems. These doc be accompanied by sufficient information and analysis to demonstrate compliance with these provisions. S101.3 Special inspection and test requirements. 220 pdf_text
14B-4-401 14B-4-401 Scope. The provisions of Section 401 of IBC are adopted by reference without modification. 24 pdf_text
14B-4-402 14B-4-402 IBC Section 402. 23 pdf_text
14B-4-402 14B-4-402 IBC Section 402. The provisions of Section 402 of IBC are not adopted. 24 pdf_text
14B-4-403 14B-4-403 High-rise buildings. The provisions of Section 403 of IBC are adopted by reference with the following modifications: 24 pdf_text
14B-4-403 14B-4-403 High-rise buildings. 23 pdf_text
14B-4-404 14B-4-404 Atriums. The provisions of Section 404 of IBC are adopted by reference with the following modifications: 27 pdf_text
14B-4-405 14B-4-405 Underground buildings. The provisions of Section 405 of IBC are adopted by reference with the following modifications: 27 pdf_text
14B-4-405 14B-4-405 Underground buildings. 23 pdf_text
14B-4-406 14B-4-406 Motor-vehicle-related occupancies. 23 pdf_text
14B-4-406 14B-4-406 Motor-vehicle-related occupancies. 27 pdf_text
14B-4-407 14B-4-407 Group I-2. The provisions of Section 407 of IBC are adopted by reference with the following modifications: 31 pdf_text
14B-4-408 14B-4-408 Group I-3. The provisions of Section 408 of IBC are adopted by reference with the following modification: 31 pdf_text
14B-4-409 14B-4-409 Motion picture projection rooms. 24 pdf_text
14B-4-409 14B-4-409 Motion picture projection rooms. The provisions of Section 409 of IBC are adopted by reference with the following modification: 31 pdf_text
14B-4-410 14B-4-410 Stages, platforms and technical production areas. The provisions of Section 410 of IBC are adopted by reference with the following modifications: 31 pdf_text
14B-4-410 14B-4-410 Stages, platforms and technical production areas. 24 pdf_text
14B-4-411 14B-4-411 Special amusement buildings. 24 pdf_text
14B-4-411 14B-4-411 Special amusement buildings. The provisions of Section 411 of IBC are adopted by reference with the following modifications: 32 pdf_text
14B-4-412 14B-4-412 Aircraft-related occupancies. 24 pdf_text
14B-4-412 14B-4-412 Aircraft-related occupancies. The provisions of Section 412 of IBC are adopted by reference with the following modifications: 32 pdf_text
14B-4-413 14B-4-413 Combustible storage. The provisions of Section 413 of IBC are adopted by reference with the following modifications: 32 pdf_text
14B-4-413 14B-4-413 Combustible storage. 24 pdf_text
14B-4-414 14B-4-414 Hazardous materials. The provisions of Section 414 of IBC are adopted by reference with the following modifications: 32 pdf_text
14B-4-414 14B-4-414 Hazardous materials. 24 pdf_text
14B-4-415 14B-4-415 IBC Section 415. 24 pdf_text
14B-4-415 14B-4-415 IBC Section 415. The provisions of Section 415 of IBC are not adopted. 33 pdf_text
14B-4-416 14B-4-416 IBC Section 416. The provisions of Section 416 of IBC are not adopted. 33 pdf_text
14B-4-416 14B-4-416 IBC Section 416. 24 pdf_text
14B-4-417 14B-4-417 IBC Section 417. 24 pdf_text
14B-4-417 14B-4-417 IBC Section 417. The provisions of Section 417 of IBC are not adopted. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 11) 33 pdf_text
14B-4-418 14B-4-418 IBC Section 418. 24 pdf_text
14B-4-418 14B-4-418 IBC Section 418. The provisions of Section 418 of IBC are not adopted. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 12) 33 pdf_text
14B-4-419 14B-4-419 Live/work units. 24 pdf_text
14B-4-419 14B-4-419 Live/work units. The provisions of Section 419 of IBC are adopted by reference with the following modifications: 33 pdf_text
14B-4-420 14B-4-420 Groups I-1, R-1, R-2, R-3, R-4 and R-5. The provisions of Section 420 of IBC are adopted by reference with the following modifications: 34 pdf_text
14B-4-420 14B-4-420 Groups I-1, R-1, R-2, R-3, R-4 and R-5. 24 pdf_text
14B-4-421 14B-4-421 IBC Section 421. The provisions of Section 421 of IBC are not adopted. 34 pdf_text
14B-4-421 14B-4-421 IBC Section 421. 24 pdf_text
14B-4-422 14B-4-422 Ambulatory care facilities. 24 pdf_text
14B-4-422 14B-4-422 Ambulatory care facilities. The provisions of Section 422 of IBC are adopted by reference with the following modifications: 34 pdf_text
14B-4-423 14B-4-423 IBC Section 423. 24 pdf_text
14B-4-423 14B-4-423 IBC Section 423. The provisions of Section 423 of IBC are not adopted. 35 pdf_text
14B-4-424 14B-4-424 IBC Section 424. 24 pdf_text
14B-4-424 14B-4-424 IBC Section 424. The provisions of Section 424 of IBC are not adopted. 35 pdf_text
14B-4-425 14B-4-425 IBC Section 425. The provisions of Section 425 of IBC are not adopted. 35 pdf_text
14B-4-425 14B-4-425 IBC Section 425. 24 pdf_text
14B-4-426 14B-4-426 IBC Section 426. 24 pdf_text
14B-4-426 14B-4-426 IBC Section 426. The provisions of Section 426 of IBC are not adopted. 35 pdf_text
14B-4-427 14B-4-427 IBC Section 427. 24 pdf_text
14B-4-427 14B-4-427 IBC Section 427. The provisions of Section 427 of IBC are not adopted. 35 pdf_text
14B-4-428 14B-4-428 IBC Section 428. The provisions of Section 428 of IBC are not adopted. CHAPTER 14B-5 GENERAL BUILDING HEIGHTS AND AREAS 35 pdf_text
14B-4-428 14B-4-428 IBC Section 428. 24 pdf_text
14B-5-501 14B-5-501 General. The provisions of Section 501 of IBC are adopted by reference with the following modification: 35 pdf_text
14B-5-502 14B-5-502 Building address. The provisions of Section 502 of IBC are adopted by reference with the following modification: 35 pdf_text
14B-5-502 14B-5-502 Building address. 35 pdf_text
14B-5-503 14B-5-503 General building height and area limitations. 35 pdf_text
14B-5-503 14B-5-503 General building height and area limitations. 35 pdf_text
14B-5-504 14B-5-504 Building height and number of stories. The provisions of Section 504 of IBC are adopted by reference with the following modifications: 36 pdf_text
14B-5-504 14B-5-504 Building height and number of stories. 35 pdf_text
14B-5-505 14B-5-505 Mezzanines and equipment platforms. The provisions of Section 505 of IBC are adopted by reference with the following modifications: 39 pdf_text
14B-5-505 14B-5-505 Mezzanines and equipment platforms. 35 pdf_text
14B-5-506 14B-5-506 Building area. The provisions of Section 506 of IBC are adopted by reference with the following modifications: 40 pdf_text
14B-5-506 14B-5-506 Building area. 35 pdf_text
14B-5-507 14B-5-507 IBC Section 507. The provisions of Section 507 of IBC are not adopted. 44 pdf_text
14B-5-507 14B-5-507 IBC Section 507. 35 pdf_text
14B-5-508 14B-5-508 Mixed use and occupancy. 35 pdf_text
14B-5-508 14B-5-508 Mixed use and occupancy. The provisions of Section 508 of IBC are adopted by reference with the following modifications: 44 pdf_text
14B-5-509 14B-5-509 Incidental uses. 35 pdf_text
14B-5-509 14B-5-509 Incidental uses. The provisions of Section 509 of IBC are adopted by reference with the following modifications: 46 pdf_text
14B-5-510 14B-5-510 IBC Section 510. The provisions of Section 510 of IBC are not adopted. CHAPTER 14B-6 TYPES OF CONSTRUCTION 47 pdf_text
14B-5-510 14B-5-510 IBC Section 510. 35 pdf_text
14B-6-601 14B-6-601 General. The provisions of Section 601 of IBC are adopted by reference with the following modification: 47 pdf_text
14B-6-602 14B-6-602 Construction classification. The provisions of Section 602 of IBC are adopted by reference with the following modifications: 48 pdf_text
14B-6-602 14B-6-602 Construction classification. 47 pdf_text
14B-6-603 14B-6-603 Combustible material in Types I and II construction. The provisions of Section 603 of IBC are adopted by reference with the following modifications: 49 pdf_text
14B-6-603 14B-6-603 Combustible material in Types I and II construction. 47 pdf_text
14B-6-604 14B-6-604 Combustible material in Types III and IV construction. 47 pdf_text
14B-6-604 14B-6-604 Combustible material in Types III and IV construction. The following language is adopted as a new Section 604: "604. COMBUSTIBLE MATERIAL IN TYPES III AND IV CONSTRUCTION 50 pdf_text
14B-6-605 14B-6-605 Basement construction. 47 pdf_text
14B-6-605 14B-6-605 Basement construction. The following language is adopted as a new Section 605: "605. BASEMENT CONSTRUCTION 50 pdf_text
14B-7-701 14B-7-701 General. The provisions of Section 701 of IBC are adopted by reference with the following modification: 51 pdf_text
14B-7-702 14B-7-702 Multiple use fire assemblies. The provisions of Section 702 of IBC are adopted by reference without modification. 51 pdf_text
14B-7-702 14B-7-702 Multiple use fire assemblies. 50 pdf_text
14B-7-703 14B-7-703 Fire-resistance ratings and fire tests. The provisions of Section 703 of IBC are adopted by reference with the following modifications: 51 pdf_text
14B-7-703 14B-7-703 Fire-resistance ratings and fire tests. 50 pdf_text
14B-7-704 14B-7-704 Fire-resistance rating of structural members. 50 pdf_text
14B-7-704 14B-7-704 Fire-resistance rating of structural members. The provisions of Section 704 of IBC are adopted by reference with the following modifications: 51 pdf_text
14B-7-705 14B-7-705 Exterior walls. 50 pdf_text
14B-7-705 14B-7-705 Exterior walls. The provisions of Section 705 of IBC are adopted by reference with the following modifications: 52 pdf_text
14B-7-706 14B-7-706 Fire walls. The provisions of Section 706 of IBC are adopted by reference with the following modifications: 57 pdf_text
14B-7-706 14B-7-706 Fire walls. 50 pdf_text
14B-7-707 14B-7-707 Fire barriers. The provisions of Section 707 of IBC are adopted by reference with the following modifications: 58 pdf_text
14B-7-707 14B-7-707 Fire barriers. 50 pdf_text
14B-7-708 14B-7-708 Fire partitions. 50 pdf_text
14B-7-708 14B-7-708 Fire partitions. The provisions of Section 708 of IBC are adopted by reference with the following modifications: 58 pdf_text
14B-7-709 14B-7-709 Smoke barriers. 50 pdf_text
14B-7-709 14B-7-709 Smoke barriers. The provisions of Section 709 of IBC are adopted by reference with the following modifications: 59 pdf_text
14B-7-710 14B-7-710 IBC Section 710. The provisions of Section 710 of IBC are not adopted. 59 pdf_text
14B-7-710 14B-7-710 IBC Section 710. 51 pdf_text
14B-7-711 14B-7-711 Floor and roof assemblies. The provisions of Section 711 of IBC are adopted by reference with the following modifications: 59 pdf_text
14B-7-711 14B-7-711 Floor and roof assemblies. 51 pdf_text
14B-7-712 14B-7-712 Vertical openings. The provisions of Section 712 of IBC are adopted by reference with the following modifications: 59 pdf_text
14B-7-712 14B-7-712 Vertical openings. 51 pdf_text
14B-7-713 14B-7-713 Shaft enclosures. The provisions of Section 713 of IBC are adopted by reference with the following modifications: 60 pdf_text
14B-7-713 14B-7-713 Shaft enclosures. 51 pdf_text
14B-7-714 14B-7-714 Penetrations. The provisions of Section 714 of IBC are adopted by reference with the following modifications: 60 pdf_text
14B-7-715 14B-7-715 Fire-resistant joint systems. The provisions of Section 715 of IBC are adopted by reference with the following modifications: 60 pdf_text
14B-7-715 14B-7-715 Fire-resistant joint systems. 51 pdf_text
14B-7-716 14B-7-716 Opening protectives. The provisions of Section 716 of IBC are adopted by reference with the following modifications: 61 pdf_text
14B-7-716 14B-7-716 Opening protectives. 51 pdf_text
14B-7-717 14B-7-717 Ducts and air transfer openings. The provisions of Section 717 of IBC are adopted by reference with the following modifications: 62 pdf_text
14B-7-717 14B-7-717 Ducts and air transfer openings. 51 pdf_text
14B-7-718 14B-7-718 Concealed spaces. The provisions of Section 718 of IBC are adopted by reference with the following modifications: 63 pdf_text
14B-7-718 14B-7-718 Concealed spaces. 51 pdf_text
14B-7-719 14B-7-719 Fire-resistance requirements for plaster. The provisions of Section 719 of IBC are adopted by reference with the following modifications: 63 pdf_text
14B-7-719 14B-7-719 Fire-resistance requirements for plaster. 51 pdf_text
14B-7-720 14B-7-720 Thermal- and sound-insulating materials. The provisions of Section 720 of IBC are adopted by reference with the following modification: 63 pdf_text
14B-7-720 14B-7-720 Thermal- and sound-insulating materials. 51 pdf_text
14B-7-721 14B-7-721 Prescriptive fire resistance. The provisions of Section 721 of IBC are adopted by reference with the following modification: 63 pdf_text
14B-7-721 14B-7-721 Prescriptive fire resistance. 51 pdf_text
14B-7-722 14B-7-722 Calculated fire resistance. The provisions of Section 722 of IBC are adopted by reference with the following modifications: 63 pdf_text
14B-7-722 14B-7-722 Calculated fire resistance. 51 pdf_text
14B-8-801 14B-8-801 Scope. The provisions of Section 801 of IBC are adopted by reference without modification. 64 pdf_text
14B-8-802 14B-8-802 General. The provisions of Section 802 of IBC are adopted by reference with the following modification: 64 pdf_text
14B-8-803 14B-8-803 Wall and ceiling finishes. 63 pdf_text
14B-8-803 14B-8-803 Wall and ceiling finishes. The provisions of Section 803 of IBC are adopted by reference with the following modifications: 64 pdf_text
14B-8-804 14B-8-804 Interior floor finish. 63 pdf_text
14B-8-804 14B-8-804 Interior floor finish. The provisions of Section 804 of IBC are adopted by reference with the following modification: 65 pdf_text
14B-8-805 14B-8-805 Combustible materials in Types I and II construction. 63 pdf_text
14B-8-805 14B-8-805 Combustible materials in Types I and II construction. The provisions of Section 805 of IBC are adopted by reference without modification. 65 pdf_text
14B-8-806 14B-8-806 Decorative materials and trim. 63 pdf_text
14B-8-806 14B-8-806 Decorative materials and trim. The provisions of Section 806 of IBC are adopted by reference with the following modifications: 65 pdf_text
14B-8-807 14B-8-807 Insulation. The provisions of Section 807 of IBC are adopted by reference without modification. 66 pdf_text
14B-8-808 14B-8-808 Acoustical ceiling systems. 64 pdf_text
14B-8-808 14B-8-808 Acoustical ceiling systems. The provisions of Section 808 of IBC are adopted by reference without modification. CHAPTER 14B-9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS 66 pdf_text
14B-9-901 14B-9-901 General. The provisions of Section 901 of IBC are adopted by reference with the following modifications: 66 pdf_text
14B-9-902 14B-9-902 Fire pump and riser room size. 66 pdf_text
14B-9-902 14B-9-902 Fire pump and riser room size. The provisions of Section 902 of IBC are adopted by reference with the following modification: 67 pdf_text
14B-9-903 14B-9-903 Automatic sprinkler systems. 66 pdf_text
14B-9-903 14B-9-903 Automatic sprinkler systems. The provisions of Section 903 of IBC are adopted by reference with the following modifications: 67 pdf_text
14B-9-904 14B-9-904 Alternative automatic fire-extinguishing systems. 66 pdf_text
14B-9-904 14B-9-904 Alternative automatic fire-extinguishing systems. The provisions of Section 904 of IBC are adopted by reference with the following modifications: 71 pdf_text
14B-9-905 14B-9-905 Standpipe systems. 66 pdf_text
14B-9-905 14B-9-905 Standpipe systems. The provisions of Section 905 of IBC are adopted by reference with the following modifications: 71 pdf_text
14B-9-906 14B-9-906 Portable fire extinguishers. 66 pdf_text
14B-9-906 14B-9-906 Portable fire extinguishers. The provisions of Section 906 of IBC are adopted by reference with the following modifications: 73 pdf_text
14B-9-907 14B-9-907 Fire alarm and detection systems. 66 pdf_text
14B-9-907 14B-9-907 Fire alarm and detection systems. The provisions of Section 907 of IBC are adopted by reference with the following modifications: 73 pdf_text
14B-9-908 14B-9-908 IBC Section 908. 66 pdf_text
14B-9-908 14B-9-908 IBC Section 908. The provisions of Section 908 of IBC are not adopted. (Amend Coun. J. 10-7-20, p. 21791, Art. II, § 17) 78 pdf_text
14B-9-909 14B-9-909 Smoke control systems. 66 pdf_text
14B-9-909 14B-9-909 Smoke control systems. The provisions of Section 909 of IBC are not adopted. The following language is adopted as Section 909: "909. SMOKE CONTROL SYSTEMS 78 pdf_text
14B-9-910 14B-9-910 Smoke and heat removal. 66 pdf_text
14B-9-910 14B-9-910 Smoke and heat removal. The provisions of Section 910 of IBC are adopted by reference with the following modifications: 79 pdf_text
14B-9-911 14B-9-911 Fire command center. The provisions of Section 911 of IBC are adopted by reference with the following modifications: 79 pdf_text
14B-9-911 14B-9-911 Fire command center. 66 pdf_text
14B-9-912 14B-9-912 Fire department connections. 66 pdf_text
14B-9-912 14B-9-912 Fire department connections. The provisions of Section 912 of IBC are adopted by reference with the following modifications: 80 pdf_text
14B-9-913 14B-9-913 Fire pumps. The provisions of Section 913 of IBC are adopted by reference with the following modifications: 81 pdf_text
14B-9-913 14B-9-913 Fire pumps. 66 pdf_text
14B-9-914 14B-9-914 Emergency responder safety features. 66 pdf_text
14B-9-914 14B-9-914 Emergency responder safety features. The provisions of Section 914 of IBC are adopted by reference with the following modifications: 81 pdf_text
14B-9-915 14B-9-915 Carbon monoxide detection. The provisions of Section 915 of IBC are adopted by reference with the following modifications: 81 pdf_text
14B-9-915 14B-9-915 Carbon monoxide detection. 66 pdf_text
14B-9-916 14B-9-916 Gas detection systems. 66 pdf_text
14B-9-916 14B-9-916 Gas detection systems. The provisions of Section 916 of IBC are adopted by reference with the following modifications: 82 pdf_text
14B-9-917 14B-9-917 IBC Section 917. The provisions of Section 917 of IBC are not adopted. 82 pdf_text
14B-9-917 14B-9-917 IBC Section 917. 66 pdf_text
14B-9-918 14B-9-918 IBC Section 918. 66 pdf_text
14B-9-918 14B-9-918 IBC Section 918. The provisions of Section 918 of IBC are not adopted. 82 pdf_text
14B-9-919 14B-9-919 City fire alarm box. 66 pdf_text
14B-9-919 14B-9-919 City fire alarm box. The following language is adopted as a new Section 919: "919. CITY FIRE ALARM BOX 82 pdf_text
15 15. Revise Section 2304.12.3, excluding the exception, to read: "2304.12.3 Wood in contact with the ground or fresh water. Wood used in contact with exposed earth shall be naturally durable wood for both decay and termite resistance or pr treated wood in accordance with AWPA U1 for soil or fresh water use." 184 pdf_text
15 15 feet (4572 mm) vertically above the roof of adjacent buildings on the same lot. 56 pdf_text
15 15. Revise Section 706.7 by deleting "approved for fireblocking." 58 pdf_text
15 15,0 S-1 NS UL 42 pdf_text
15 15 to less than 20 f, g, j Unprotected, Nonsprinklered (UP, NS) 55 pdf_text
15 15% Unprotected, Sprinklered (UP, S) i 55 pdf_text
15 15. Revise Section 1507.13.3 to read: "1507.13.3 Ballasted thermoplastic low-sloped roofs. Ballasted thermoplastic low-sloped roofs shall be installed in accordance with this section and Section 1504.4. Stone shall comply with ASTM D448 or ASTM D7655." 137 pdf_text
15 15. Revise Section 1107.6.3, including the exception, to read: "1107.6.3 Attached residential buildings. Where there are four or more Group R dwelling units or sleeping units in a single structure, even if that structure is c multiple buildings under other provisions of this code, the structure shall comply with Section 1107.6.1 or 1107.6.2. within Group R congregate living facilities shall be counted as sleeping units for the purpose of determining the num 115 pdf_text
15 15. Revise Section 717.6.1 by deleting "approved." 62 pdf_text
15 15. Revise Section 1011.12 to read: "1011.12 Stairway to roof. In buildings with four or more stories above grade plane, one stairway shall extend to the roof surface unless the roo greater than or equal to three units vertical in 12 units horizontal (25-percent slope). Exception: Other than where required by Section 1011.12.1, in buildings without an occupiable rooftop, acc from the top story shall be permitted to be by an alternating tread device, a ship's ladder or a permanent ladde 97 pdf_text
15 15,0 F-2 NS UL UL 41 pdf_text
15 15. Revise Section 1006.3.3 to read: "1006.3.3 Single exits. A single exit or access to a single exit shall be permitted from any story or occupiable rooftop where one of the follo conditions exists: 89 pdf_text
15 15. Delete Section 1705.11 and its subsections. 158 pdf_text
15 15. Delete exception 5 to Section 705.11 and its subparts. 56 pdf_text
15 15. Revise Section 406.5.8 to read: "406.5.8 Fire protection systems. An open parking garage shall be equipped with a standpipe system as required by Section 905.3. An open parking g equipped with an automatic sprinkler system as required by Section 903.2.10." 30 pdf_text
15 15. Revise Section D105.1 to read: "D105.1 General. Nothing in this appendix shall prohibit within the fire limits, subject to the specified limitations, the erection of new structures, nor the enlargement of existing buildings or structures, nor the use of wood or other combustible veneers, 219 pdf_text
15 15. Revise Section 907.2.6.3.1 to read: "907.2.6.3.1 System initiation. Actuation of an automatic fire-extinguishing system, automatic sprinkler system, a manual fire alarm box or a fire de initiate a private operating mode fire alarm signal that automatically notifies staff throughout the facility." 74 pdf_text
15 15. Delete Section 2702.4. 196 pdf_text
15 15,0 R-3 h NS UL UL 42 pdf_text
15 15. Revise exception 1 to item 1 in Section 403.4.7 by deleting "or suite." 25 pdf_text
15 15,0 R-2 NS UL UL 42 pdf_text
15 15. Roofs over parking lots and bus stations of Type IIB construction where the roof is at least 10 fe above the floor and every 40 feet (12.2 m) there is an open roof ventilation area at least 6 feet (1829 extending either the full length of the roof or the full width of the roof." 219 pdf_text
15 15. Revise note l to Table 1607.1 to read: "l. Areas of occupiable rooftops accessible from a single dwelling unit shall be designed in accordance with of roofs with vegetation and not intended for occupancy shall be designed in accordance with Section 1607.1 147 pdf_text
15 15. Revise Section 1810.3.3.1.2 to read: "1810.3.3.1.2 Load tests. Where design compressive loads are greater than those determined using the allowable stresses specified in Section 1 where the design load for any deep foundation element is in doubt or exceeds the value in Table 1810.3.3.1.2, or whe place deep foundation elements have an enlarged base formed either by compacting concrete or by driving a precast 171 pdf_text
15 15. Revise Section 1004.8 to read: "1004.8 Concentrated business use areas. The occupant load factor for concentrated business use shall be applied to telephone call centers, trading floors, data centers and similar business use areas with a higher density of occupants than would normally be expected in a typic occupancy environment. The occupant load for concentrated business use areas shall be the actual occupant load, bu one occupant per 50 square feet (4.65 m2) of net floor area." 86 pdf_text
15 15,0 R-1 h NS d UL UL 42 pdf_text
15 15 psi and 10 horsepower 46 pdf_text
15 15. Revise Table 2308.5.11 by deleting the row for "Hardboard panel siding" and adding a row to read: "Cement board sheathing | 1/2 inch | 16 inches on center" 186 pdf_text
15 15. Add a new Section 903.2.4.2 to read: 68 pdf_text
15 15. Revise the exceptions to Section 1010.1.7 to read: "Exceptions: 93 pdf_text
15 15,0 R-4 h NS d UL UL 42 pdf_text
15 15. Revise Table 1029.13.2.1 by deleting "SMOKE-PROTECTED OR." 105 pdf_text
15 15. Revise the definition of "approved" to read: "APPROVED. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions." 4 pdf_text
15 15. Revise Section 1404.11 to read: "1404.11 Metal veneers. Veneers of metal shall be fabricated from corrosion-resistant materials or shall be protected front and back with porc or otherwise be treated to render the metal resistant to corrosion." 130 pdf_text
15 15. Revise Section 1803.6 to add new items to read: "11. Construction considerations: earth retention systems, underpinning, excavation slopes, effects on adjac utilities and improvements, corrosivity, drainage systems and dewatering, as necessary. 164 pdf_text
15 15,0 R-5 NS UL UL 42 pdf_text
15 15. Delete the entire section for WRI. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 103; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 34; Amend Coun. J. 6-25-2 Art. II, § 28; Amend Coun. J. 9-21-22, p. 52080, Art. II, § 7) CHAPTER 14B-36 APPENDICES 217 pdf_text
15 15. Generator supervision devices, manual start and transfer features. 80 pdf_text
15 15. Revise Section 2603.9 by replacing "specifically approved" with "approved." 193 pdf_text
15.1 15.1. Revise Section 2308.6.1 by deleting the last sentence. 186 pdf_text
15.2 15.2. Revise Table 2308.6.1 by deleting the row for a two-story building in Seismic Design Category C and all row Design Categories D and E. 186 pdf_text
150 150 percent of supply. Supply air shall enter and exhaust air shall discharge from the vestibule throug tightly constructed ducts used only for that purpose. Supply air shall enter the vestibule within 6 inche the floor level. The top of the exhaust register shall be located at the top of the smoke trap but not mor inches (152 mm) down from the top of the trap, and shall be entirely within the smoke trap area. Door position shall not obstruct duct openings. Duct openings with controlling dampers are permitted wher meet the design requirements, but dampers are not otherwise required. 228 pdf_text
150 150. Insert the following definition: "LOT OF RECORD. See "Lot." 11 pdf_text
150 150 feet of floor surface, exclusive of stairs, per dwelling unit U No Yes Yes P, UNC Yes Yes Yes Repair or replacement of enclosed porches existing on December 31, 2018, serving no more than 3 stories above grade plane P1 Yes Yes Yes U No No Yes Repair or replacement of porches existing on January 20, 54 pdf_text
151 151. Revise the definition of "lower flammable limit (LFL)" to read: "LOWER FLAMMABLE LIMIT (LFL). As defined in Chapter 2 of the Chicago Fire Prevention Code." 11 pdf_text
1510.1.1 1510.1.1 Area limitation. The combined area of parapet walls, unoccupied rooftop structures, rooftop access penthouses in accordance 138 pdf_text
1510.2 1510.2 and structures accessory to an occupiable rooftop in accordance with Section 1513.1.1 shall not excee area of the supporting roof deck. Such rooftop structures shall not be required to be included in determining b number of stories above grade plane or building area in accordance with Chapter 2, nor shall the area of suc structures be included in determining the fire areas specified in Section 901.7. Exception: If the combined area of rooftop structures exceeds one-third the horizontal area of the sup deck, the height and area of the rooftop structures shall be considered in determining building height, stories above grade plane, building area and fire area." 138 pdf_text
1510.2.1 1510.2.1 Height above roof deck. Mechanical penthouses shall not exceed 18 feet (5486 mm) in height above the roof deck as measured to the of the roof of the penthouse. Exception: On buildings of Type I construction, mechanical penthouses shall be permitted to have a height of 28 feet (8534 mm) above the roof deck. 138 pdf_text
1510.2.2 1510.2.2 Use limitations. Mechanical penthouses shall not be used for purposes other than the shelter of mechanical or electrical equip elevators and related machinery, or vertical shaft openings in the roof assembly. 138 pdf_text
1510.2.3 1510.2.3 Weather protection. Provisions such as louvers, louver blades or flashing shall be made to protect the mechanical and electrical eq the building interior from the elements. 138 pdf_text
1510.2.4 1510.2.4 Type of construction. Mechanical penthouses shall be constructed with walls, floors and roofs as required for the type of constructi building on which such penthouses are built. Exceptions: 138 pdf_text
1510.5.1 1510.5.1 Noncombustible construction required. Features greater than 60 feet (18 288 mm) in height above the highest point at which such feature contacts th measured to the highest point on such feature, or that exceeds 200 square feet (18.6 m2) in area at any horizo which is intended to be used for any purpose other than a belfry or architectural embellishment, or is located building greater than 50 feet (1524 mm) in building height shall be constructed of and supported by noncomb materials and shall be separated from the building below by construction having a fire-resistance rating of no hours with openings protected in accordance with Section 711. Such features located on the top of a building feet (15 240 mm) in building height shall be supported by noncombustible construction. 139 pdf_text
1510.5.2 1510.5.2 Enclosed features Enclosed features shall have exterior walls constructed as required for the building on top of which such feat The roof covering of features shall be not less than the same class of roof covering required for the building o the feature is located." 139 pdf_text
1511.1 1511.1 General. Roof repairs and roof replacement shall comply with Section 306 of the Chicago Building Rehabilitation Code." 140 pdf_text
1513.1 1513.1 General. The provisions of this section shall govern the construction of occupiable rooftops and associated rooftop structures. 140 pdf_text
1513.1.1 1513.1.1 Area limitation. The combined area of rooftop structures associated with an occupiable rooftop and exceeding 48 inches (121 height above the lowest walking surface of the occupiable rooftop shall comply with Section 1510.1.1. 140 pdf_text
1513.2 1513.2 Rooftop access penthouses. Where the occupied rooftop is located above the highest story, penthouses providing access to or egress from an occ in compliance with Sections 1513.2.1 through 1513.2.5 shall be considered as a portion of the story directly below th which such penthouses are located. Other fully-enclosed occupiable space at the roof level shall be considered as an story of the building. 140 pdf_text
1513.2.1 1513.2.1 Height above roof deck. Rooftop access penthouses shall not exceed 12 feet (3658 mm) in height above the roof deck as measured to t height of the roof of the penthouse. Exception: Where used to enclose elevators that travel to the roof level, rooftop access penthouses sh permitted to have a maximum height of 20 feet (6096 mm) above the roof deck. 140 pdf_text
1513.2.2 1513.2.2 Use limitations. Rooftop access penthouses shall not contain habitable space or any occupiable space other than circulation p to access means of egress and elevators serving an occupiable rooftop. Rooftop access penthouses shall not c rooms or bathrooms. 140 pdf_text
1513.2.3 1513.2.3 Type of construction. Rooftop access penthouses shall be constructed with walls, floors and roofs as required for the type of constr building on which such penthouses are built. 140 pdf_text
1513.3 1513.3 Outdoor elements. The walking surface and other outdoor elements of an occupiable rooftop shall comply with the requirements of Sect through 1513.3.2. 140 pdf_text
1513.3.1 1513.3.1 Buildings not exceeding 55 feet in building height. The outdoor elements of occupiable rooftops on buildings not exceeding 55 feet (16.8 m) in building height s noncombustible materials or combustible materials as allowed by Table 1513.3.1 or Table 705.2.1 or 705.2.2 Outdoor elements not listed in the tables shall conform to the type of construction and fire-resistance rating r building to which they are attached. TABLE 1513.3.1 REQUIRED FIRE SEPARATION DISTANCE FOR OUTDOOR ELEMENTS OF OCCUPIABLE ROOFTOPS ON BUILDINGS UP TO 55 FEET IN BUILDING HEIGHT a Material Fire Separation Distance 140 pdf_text
1513.3.2 1513.3.2 Buildings greater than 55 feet in height. The outdoor elements of occupiable rooftops on buildings greater than 55 feet (16.8 m) in height shall be of n materials. Exceptions: 141 pdf_text
1513.4 1513.4 Structures providing weather protection. Structures above an occupiable rooftop that provide weather protection equivalent to a roof and project more than 24 mm) horizontally from a wall or other support shall be treated as part of the building to which they are attached for p determining building height and number of stories above grade plane. 141 pdf_text
1513.5 1513.5 Means of egress. 141 pdf_text
1513.6 1513.6 Construction type. Occupiable rooftops shall not be installed on buildings of Type VB construction. The roof assembly below an occupi shall have a fire-resistance rating of not less than 1 hour." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 71) 142 pdf_text
1514.1 1514.1 General. Vegetative roofs, roof gardens and landscaped roofs shall be installed and maintained in accordance with Sections 15 and 1514.2 through 1514.6. 142 pdf_text
1514.1.1 1514.1.1 Intended for occupancy. Vegetative roofs, roof gardens and landscaped roofs that are intended for occupancy shall also comply with S 142 pdf_text
1514.2 1514.2 Standard. Vegetative roofs, roof gardens and landscaped roofs shall be installed in accordance with ANSI/SPRI VF-1. 142 pdf_text
1514.3 1514.3 Maximum area. Vegetative roof, roof garden or landscaped roof areas shall not exceed 15,625 square feet (1450 m2) for any single ar maximum dimension of 125 feet (39 m) in length and width. A minimum 6 foot (1.8 m) wide clearance consisting of covering shall be provided between adjacent vegetative roof, roof garden or landscaped roof areas. 142 pdf_text
1514.4 1514.4 Clearances. Vegetative roof, roof garden and landscaped roof areas shall be separated from combustible vertical surfaces, intake openings and rooftop equipment by a 6 foot (1.8 m) wide surface consisting of Class A roof covering. Exception: Separation from plumbing exhaust openings is not required. 142 pdf_text
1514.5 1514.5 Maintenance. Vegetation shall be maintained in accordance with Sections 1514.5.1 through 1514.5.3. 142 pdf_text
1514.5.1 1514.5.1 Maintenance plan. The fire code official is authorized to require a maintenance plan for vegetation placed on roofs. 142 pdf_text
1514.5.2 1514.5.2 Water source. A water source shall be provided to maintain levels of hydration necessary to keep vegetation alive and to ke to a minimum. 142 pdf_text
1514.5.3 1514.5.3 Dead foliage. Excess biomass, such as overgrown vegetation, leaves and other dead and decaying material shall be remove intervals not less than two times per year. 142 pdf_text
1514.6 1514.6 Maintenance equipment. Fueled equipment used for the care and maintenance of vegetation on roofs shall be stored in accordance with the C Prevention Code." 142 pdf_text
1515.1 1515.1 Scope. Roof coverings shall comply with the solar reflectance requirements in Section 1515.2. Exceptions: 142 pdf_text
1515.2 1515.2 Solar reflectance. All roof coverings shall have a minimum solar reflectance as specified in Sections 1515.2.1 or 1515.2.2 as tested in a ASTM C1549, ASTM E903, ASTM E1918 or CRRC-S100. 143 pdf_text
1515.2.1 1515.2.1 Low-sloped roofs. Roof coverings on low-sloped roofs shall have an initial reflectance value of 0.72 or a three-year-aged solar re value of 0.5 or greater. Exceptions: 143 pdf_text
1515.2.2 1515.2.2 Other than low-sloped roofs. Roof coverings on other than low-sloped roofs shall have an initial reflectance value of 0.15 or greater. Exceptions: 143 pdf_text
1516.1 1516.1 Scope. Low-sloped roofs shall comply with the applicable requirements in Sections 1516.2 and 1516.3. 143 pdf_text
1516.2 1516.2 Roof edges adjoining shafts and fully enclosed courts. The edges of a low-sloped roof that adjoin a shaft or a court that is enclosed on all sides shall be provided with a para masonry, or guard, or any combination thereof, that meets the requirements of Section 1015. 143 pdf_text
1516.3 1516.3 Skylights and other openings. All skylights and other openings located in the plane of a low-sloped roof that are not otherwise required to remain o unobstructed by law shall be either: (i) glazed with wired glass, plain glass, or glass block that is designed to meet th live load requirements for the roof under Section 1607; or (ii) provided with a parapet, extended masonry, or guard, combination thereof, that meets the requirements of Section 1015.” (Added Coun. J. 10-9-24, p. 18818, § 1) CHAPTER 14B-16 STRUCTURAL DESIGN 143 pdf_text
152 152. Delete the definition of "lowest floor." 11 pdf_text
153 153. Insert the following definition: "LOW-SLOPED ROOF. A roof with a slope of less than two units vertical in 12 units horizontal (17 percent slope) 11 pdf_text
154 154. Insert the following definition: "MAILBOXES (for Chapter 11). Receptacles for the receipt of documents, packages or other deliverable matter. include, but are not limited to, post office boxes and receptacles provided by commercial mail- receiving agencies, a facilities or schools." 11 pdf_text
155 155. Delete the definition of "mall building, covered" and "mall building, open." 11 pdf_text
156 156. Insert the following definition: "MARKED CROSSING (for Chapter 11). A crosswalk or other identified path intended for pedestrian use in cros vehicular way." 11 pdf_text
157 157. Revise the definition of "means of egress" to read: 11 pdf_text
158 158. Insert the following definition: "MEANS OF EGRESS (for Chapter 11). A continuous and unobstructed way of egress travel from any point in a facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way." 12 pdf_text
159 159. Insert the following definition: "MEAN ROOF HEIGHT. The average of the eave height and the vertical distance from grade plane to the highest highest roof surface, except that for roof slopes of less than 10 percent, the mean roof height is permitted to be taken height." 12 pdf_text
16 16. Revise exception 2 to Section 903.2.6 to read: "2. An automatic sprinkler system is not required where Group I-4 day care facilities are at the level of exit where every room where care is provided has not fewer than one exterior exit door." 69 pdf_text
16 16. Add a new exception following Section 1803.6 to read: "Exception: For construction not exceeding four stories above grade plane, not requiring excavation more than 8 fe below existing grade, and not covering more than 16,000 square feet (1486.4 m2) of ground area, a written report of investigations shall not be required at the time of permit application but shall be completed prior to the actual start of to confirm presumed conditions used as the basis for design. The report shall be made available to the building offici request. Where the written report of geotechnical investigations, completed after permit application, does not confir conditions used as the basis for design, a revised permit application and revised construction documents shall be sub building official and construction shall not commence until the revised permit has been issued." 164 pdf_text
16 16. Revise Section 706.11 by replacing "lot line" with "property line." (Amend Coun. J. 6-25-21, p. 32180, Art. II, § 10; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 7) 58 pdf_text
16 16. Add a new note p to Table 1607.1 to read: "p. Where actual fixed equipment loads are known, permanent aisles shall be allowed to be designed for a li pounds per square foot and equipment areas shall be allowed to be designed for the actual dead loads." 147 pdf_text
16 16. Revise Section 1507.15 to read: "1507.15 Liquid-applied roofing. The installation of cold and hot applied liquid-applied roofing shall comply with the provisions of this section." 137 pdf_text
16 16. Revise the exception to Section 717.6.1 by replacing "three floors" with "four floors." 62 pdf_text
16 16. Revise Section 2603.11 by replacing "approved" with "engineered." 193 pdf_text
16 16. Revise Section 403.4.8.1, excluding the exception, to read: "403.4.8.1 Equipment room. If the standby power system or emergency power system includes a generator set inside a building, the generator set s in a separate room enclosed with 2-hour fire barriers constructed in accordance with Section 707 or horizontal assem constructed in accordance with Section 711, or both. System supervision with manual start and transfer features shall the fire command center." 25 pdf_text
16 16. Public address system, where specifically required by other sections of this code. 80 pdf_text
16 16. Revise Section 1107.6.4.1 to read: "1107.6.4.1 Accessible units. In Group R-4, Condition 1, at least one of the sleeping units shall be an Accessible unit. In Group R-4, Condition 2, a the sleeping units shall be Accessible units. In Group R-4, Condition 1 or Condition 2, owned or financed by a governmental unit, at least 20 percent of the sleep be Accessible units." 115 pdf_text
16 16. Revise Section 907.2.6.3.2 to read: "907.2.6.3.2 Manual fire alarm boxes. Manual fire alarm boxes are not required to be located in accordance with Section 907.4.2 where manual fire alarm provided at staff-attended locations having direct supervision over areas where manual fire alarm boxes have been o 74 pdf_text
16 16. Delete Section D106. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 104) 219 pdf_text
16 16. Revise Section 1011.12.2 to read: 97 pdf_text
16 16. Insert new Table 1810.3.3.1.2 to read: TABLE 1810.3.3.1.2 MAXIMUM AXIAL LOADS ALLOWED WITHOUT LOAD TEST For SI: 1 ton = 907 kg a. Nondestructive tests are required for non-driven piles. 172 pdf_text
16 16. Revise Table 2308.6.3(5) by deleting all rows for "direct to studs" siding. 186 pdf_text
16 16. Delete item 2 in Section 406.5.11. 30 pdf_text
16 16. Revise Section 1004.9 to read: "1004.9 Posting of maximum capacity signs. Maximum capacity signs shall be posted where required by Section 802 of the Chicago Construction Codes Adminis Provisions." 86 pdf_text
16 16. Revise the exceptions to Section 1010.1.8 to read: "Exceptions: 94 pdf_text
16 16. Replace Table 1006.3.3(1) as shown: TABLE 1006.3.3(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2, R-3, R-4 AND R-5 OCCUPANCIES 90 pdf_text
16 16. Delete Section 2304.12.4. 184 pdf_text
16 16. Revise the definition of "approved agency" to read: "APPROVED AGENCY. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions." 4 pdf_text
16 16. Revise Section 1705.12 and its subsections to read: "1705.12 Special inspections for seismic resistance for Risk Category IV buildings. Special inspections for seismic resistance for Risk Category IV buildings shall be required as specified in Sections 1 through 1705.12.9, unless exempted by the exceptions of Section 1704.2. Exception: The special inspections specified in Sections 1705.12.1 through 1705.12.9 are not required for st designed and constructed in accordance with one of the following: 158 pdf_text
16 16. Revise Section 1404.11.1 to read: "1404.11.1 Attachment. Exterior metal veneer shall be securely attached to the supporting masonry or framing members with corrosion- resis metal ties or by other approved devices or methods. Such attachments and their supports shall be designed and const the wind loads as specified in Section 1609 for components and cladding." 130 pdf_text
16 16. Revise the exception to Section 1029.13.2.2 by deleting "smoke-protected or." 105 pdf_text
16.1 16.1. Delete Section 406.6.1. 30 pdf_text
160 160. Insert the following definition: "MULTI-STORY HOUSING (for Chapter 11). Any building of four or more stories containing ten or more dwell sleeping units constructed to be held out for sale or lease by any person to the public. Multi-story housing includes, b limited to, the following building types: apartment buildings, condominium buildings, convents, housing for the elde monasteries." 12 pdf_text
1607.8.1.1 1607.8.1.1 shall be applied." 148 pdf_text
1609.3.1 1609.3.1 shall be used when the provisions of the standards referenced in Exceptions 4 and 5 are used." 149 pdf_text
1609.6.1 1609.6.1 Main windforce-resisting system. The load due to wind pressure, W, on the main windforce-resisting system shall be based on exposure categor category as indicated in Table 1609.6.1. TABLE 1609.6.1 149 pdf_text
1609.6.2 1609.6.2 Components and cladding. The load due to wind pressure, W, on components and cladding shall be the values in Table 1609.6.1 multipli multiplier provided in Table 1609.6.2. TABLE 1609.6.2 MULTIPLIERS TO DETERMINE COMPONENTS AND CLADDING WIND PRESSURE For SI: 1 foot = 304.8 mm, 1 degree = 0.017 rad. a. Wall pressures shall act toward (positive) or away (negative) from the surface. b. Roof pressures shall be considered as acting away (negative) from the surface. c. Wall corners shall be defined as a distance from the corner equal to the lesser of 0.1 times the least horizontal dimension or 0.4 times the height in bot (minimum 3 feet). d. Flat roof edges shall be defined as a distance from the roof edge of 1.2 times the height. e. Flat roof corners shall be defined as a distance from each roof corner of 0.6 times the height (for a width of 0.2 times the height). f. Sloped gable roof edges shall be defined as a distance from the roof edge equal to the lesser of 0.1 times the least horizontal dimension or 0.4 times th (minimum 3 feet) from the roof edge. 150 pdf_text
161 161. Insert the following definition: "NET FLOOR AREA. See "Floor area, net." 12 pdf_text
1612.1 1612.1 General. Development in special flood hazard areas shall comply with Chapter 16-6 of the Municipal Code." 151 pdf_text
1613.2.1 1613.2.1 Acceleration parameters. The acceleration parameters shall be: mapped 0.2 sec. spectral response acceleration (5% of critical damping, Ss = 0.125 g and mapped 1.0 sec. spectral response acceleration (5% of critical damping, Site Class B) S1 = 0 152 pdf_text
1613.2.2 1613.2.2, shall be designed and constructed to withstand maximum imposed curvatures from earthquake ground mot structure response." 170 pdf_text
1613.2.2 1613.2.2 Site class definitions. Based on the site soil properties, the site shall be classified as Site Class A, B, C, D, E or F in accordance wit of ASCE 7. The site class shall reflect the soil conditions that affect the ground motion input to the structure. Where the soil properties are not known in sufficient detail to determine the site class, Site Class D, subjecte requirements of Section 1613.2.3, shall be used unless the building official or a registered geotechnical engin that Site Class E or F soils are present at the site. Where site investigations that are performed in accordance with Chapter 20 of ASCE 7 reveal rock condition with Site Class B, but site-specific velocity measurements are not made, the site coefficients Fa and Fv shall unity (1.0). 152 pdf_text
1613.2.3 1613.2.3 Site coefficients and adjusted maximum considered earthquake spectral response acceleration The maximum considered earthquake spectral response acceleration for short periods, SMS, and at 1-second p adjusted for site class effects and five-percent damped design spectral response acceleration at short periods, second period, SD1 shall be as provided in Table 1613.2.3. Where the simplified design procedure of ASCE 7 Section 12.14 is used, these values shall be determined in with ASCE 7 Section 12.14.8.1. TABLE 1613.2.3 SEISMIC DESIGN PARAMETERS 152 pdf_text
1613.2.5 1613.2.5 Determination of seismic design category. Structures shall be assigned to a Seismic Design Category in accordance with Table 1613.2.3. 153 pdf_text
1613.2.5.2 1613.2.5.2 Simplified design procedure. Where the alternate simplified design procedure of ASCE 7 is used, the seismic design category shall in accordance with ASCE 7." 153 pdf_text
1613.4.1 1613.4.1 General. All structures shall be provided with a continuous load path in accordance with the requirements of Section 1 shall have a complete lateral force-resisting system with adequate strength to resist the forces indicated in Sec All members of the structural system shall be connected to their supporting members in accordance with Sect Structural walls shall be anchored to diaphragms and supports in accordance with Section 1613.4.5. The effec structure and its components caused by the forces stipulated in this section shall be taken as the notional load combined with the effects of other loads in accordance with the load combinations of Section 1605. Where m resistance depends on load duration, notional loads are permitted to be taken as having a duration of 10 minut 153 pdf_text
1613.4.2 1613.4.2 Load path connections. All parts of the structure between separation joints shall be interconnected to form a continuous path to the la resisting system, and the connections shall be capable of transmitting the lateral forces induced by the parts b connected. Any smaller portion of the structure shall be tied to the remainder of the structure with elements h strength to resist a force of not less than 5% of the portion’s weight. 153 pdf_text
1613.4.3 1613.4.3 Lateral forces. Each structure shall be analyzed for the effects of static lateral forces applied independently in each of two or directions. In each direction, the static lateral forces at all levels shall be applied simultaneously. For purpose the force at each level shall be determined using Equation 16-36a. Fx = 0.01Wx (Equation 16-36a) where: Fx = The design lateral force applied at level x. Wx = the portion of the total dead load of the structure, D, located or assigned to level x. 153 pdf_text
1613.4.4 1613.4.4 Connection to supports. A positive connection for resisting a horizontal force acting parallel to the member shall be provided for each or truss either directly to its supporting elements or to slabs designed to act as diaphragms. Where the connec a diaphragm, the member’s supporting element shall also be connected to the diaphragm. The connection sha strength to resist a force of 5% of the unfactored dead load plus live load reaction imposed by the supported supporting member. 153 pdf_text
1613.4.5 1613.4.5 Anchorage of structural walls. Walls that provide vertical load bearing or lateral shear resistance for a portion of the structure shall be ancho and all floors and members that provide lateral support for the wall or that are supported by the wall. The anc provide a direct connection between the walls and the roof or floor construction. The connections shall be cap resisting a strength level horizontal force perpendicular to the plane of the wall equal to 0.2 times the weight 153 pdf_text
162 162. Insert the following definition: "OCCUPIABLE ROOFTOP. An exterior floor structure or walking surface, intended for human occupancy, other occasional use by maintenance and service personnel, that is installed above a roof deck. " 12 pdf_text
163 163. Revise the definition of "occupiable space" to read: "OCCUPIABLE SPACE. A room or enclosed space intended for human occupancy in which individuals reside; co amusement, education or similar purposes; or are engaged at labor, and which is required to be equipped with means light and ventilation facilities by this code. All habitable spaces are occupiable spaces. A space which is only require to be provided with means of access by maintenance and service personnel is not an occupiable space." 12 pdf_text
164 164. Revise the definition of "open system" to read: "OPEN SYSTEM. As defined in Chapter 2 of the Chicago Fire Prevention Code." 12 pdf_text
165 165. Revise the definition of "operating building" to read: "OPERATING BUILDING. As defined in Chapter 2 of the Chicago Fire Prevention Code." 12 pdf_text
166 166. Revise the definition of "organic peroxide" to read: "ORGANIC PEROXIDE. As defined in Chapter 2 of the Chicago Fire Prevention Code." 12 pdf_text
167 167. Revise the definition of "owner" to read: "OWNER. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions." 12 pdf_text
168 168. Revise the definition of "oxidizer" to read: "OXIDIZER. As defined in Chapter 2 of the Chicago Fire Prevention Code." 12 pdf_text
169 169. Revise the definition of "oxidizing gas" to read: "OXIDIZING GAS. As defined in Chapter 2 of the Chicago Fire Prevention Code." 12 pdf_text
17 17. Revise Section 403.4.8.2 to read: "403.4.8.2 Fuel line piping protection. Fuel lines supplying a generator set inside a building shall be of double wall pipe with leak detection provided in the space and separated from areas of the building other than the room the generator is located in by an assembly that ha resistance rating of not less than 2 hours." 25 pdf_text
17 17. Add new Section 705.12 to read: "705.12 Easements. The building official may adopt rules for considering permanent and perpetual easements or restrictive declarations o lots as a means of adjusting requirements in this section based on fire separation distance." 56 pdf_text
17 17. Revise Section 1404.11.2 to read: "1404.11.2 Weather protection. Metal supports for exterior metal veneer shall be corrosion-resistant. Wood studs, furring strips or other wood suppo metal veneer shall be pressure-treated wood or protected as required in Section 1402.2. Joints and edges exposed to t shall be caulked with durable waterproofing material or by other approved means to prevent penetration of moisture. 130 pdf_text
17 17. Revise Section 1507.15.2 to read: "1507.15.2 Material standards. Liquid-applied roofing shall comply with ASTM C836, ASTM C957, ASTM D1227 or ASTM D3468, ASTM D608 D6694, ASTM D6947 or other approved material standard." 137 pdf_text
17 17. Revise the exceptions to Section 907.2.7 to read: "Exception: Manual fire alarm boxes are not required where the building is equipped throughout with an automatic system installed in accordance with Section 903.3.1.1 and the occupant notification appliances will activate in accord 75 pdf_text
17 17. Delete exception 3 to Section 903.2.6. 69 pdf_text
17 17. Revise Section 2308.6.5.1 by deleting "approved." 186 pdf_text
17 17. Revise Section 1107.6.4.2, excluding the exception, to read: "1107.6.4.2 Type B units. In structures with four or more sleeping units, every sleeping unit shall be a Type B unit." 115 pdf_text
17 17. Revise exception 3 to Section 1029.15 by replacing "three" with "five." 105 pdf_text
17 17. Revise Section 1010.1.9.4 to read: "1010.1.9.4 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exist: 94 pdf_text
17 17. Revise Section 1810.3.3.1.3 to read: "1810.3.3.1.3 Load test evaluation methods. Load test results must be accepted by the registered geotechnical engineer who prepared the geotechnical investigati unless otherwise approved by the building official. It shall be permitted to evaluate load tests of deep foundation ele of the following methods: 172 pdf_text
17 17. Revise Section 717.6.2 by deleting "approved." 62 pdf_text
17 17. Elevator fire recall switch in accordance with the Chicago Conveyance Device Code. 80 pdf_text
17 17. Revise the exception to Section 406.6.2 to read: "Exception: Mechanical ventilation shall not be required for private garages." 30 pdf_text
17 17. Revise Section 1607.2 to read: "1607.2 Loads not specified. For occupancies or uses not designated in Table 1607.1, the live load shall be approved by the building official." 147 pdf_text
17 17. Insert a new Section 1004.10 to read: "1004.10 Limited areas used for assembly-type functions. Where a Group B, F or M occupancy contains limited areas used for functions classified as either "assembly" or "ass fixed seats" in accordance with Table 1004.5, the occupant load for those areas shall be determined in accordance wi 86 pdf_text
17 17. Add a new exception to Section 1705.13 to read: "Exception: Buildings and structures assigned to Seismic Design Category A or B." 160 pdf_text
17 17. Delete the definition of "approved source." 4 pdf_text
17 17. Revise Section 1011.14 by adding the following after the last sentence: "The minimum clear width at and below the handrails shall be 20 inches (508 mm)." 98 pdf_text
17 17. Revise exception 1 to Section 2603.11 by deleting "approved." Revise Section 2603.12 to read: "2603.12 Cladding attachment over foam sheathing to cold-formed steel framing. Cladding shall be specified and installed in accordance with Chapter 14 and the cladding manufacturer’s installation including any limitations for use over foam plastic sheathing, or an engineered design. Where used, furring and furri shall be designed to resist design loads determined in accordance with Chapter 16. In addition, the cladding or furrin through foam sheathing to cold-formed steel framing shall meet or exceed the minimum fastening requirements of S 193 pdf_text
17 17. Delete Table 1006.3.3(2). 91 pdf_text
17.1 17.1. Revise item 4 in Section 903.2.7 to read: "4. A Group M occupancy where the area used for the display and sale of upholstered furniture or mattresse 69 pdf_text
170 170. Insert the following definition: "PARKING FACILITY (except for Chapter 11). A multi-level structure in which each level is used primarily for storing private motor vehicles, and which does not necessarily have enclosing walls." 12 pdf_text
1703.6.1 1703.6.1 Follow-up inspection. The owner shall provide for special inspections of fabricated items in accordance with Section 1704.2.5. 155 pdf_text
1703.6.2 1703.6.2 Test and inspection records. Copies of necessary test and special inspection records shall be maintained by the owner and made available t official." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 77) 155 pdf_text
1704.2.1.1 1704.2.1.1 Evidence of qualifications. A special inspection agency shall provide all information as necessary for the owner to determine that the ag applicable requirements specified in Sections 1704.2.1.1.1 through 1704.2.1.1.3. 156 pdf_text
1704.2.1.1.1 1704.2.1.1.1 Independence. A special inspection agency shall be objective, competent and independent from the contractor respon work being inspected. The agency shall disclose to the owner and the registered design professional i charge possible conflicts of interest so that objectivity can be confirmed. 156 pdf_text
1704.2.1.1.2 1704.2.1.1.2 Equipment. A special inspection agency shall have adequate equipment to perform required tests. The equipment periodically calibrated. 156 pdf_text
1704.2.1.1.3 1704.2.1.1.3 Personnel. A special inspection agency shall employ experienced personnel educated in conducting, supervising tests and special inspections. 156 pdf_text
1704.6.1 1704.6.1 Structural observations for structures. Structural observations shall be provided for those structures where the work involves construction or altera primary structural frame and one or more of the following conditions exist: 157 pdf_text
1704.6.2 1704.6.2 Structural observations for seismic resistance - Risk Category IV. Structural observations shall be provided for those structures assigned to Seismic Design Category D where t classified as Risk Category IV." 157 pdf_text
1705.12.1 1705.12.1 Structural steel. Special inspections for seismic resistance shall be in accordance with Section 1705.12.1.1 or 1705.12.1.2, as 158 pdf_text
1705.12.1.1 1705.12.1.1 Seismic force-resisting systems. Special inspections of structural steel in the seismic force-resisting systems in buildings and structures Seismic Design Category C, D, E or F shall be performed in accordance with the quality assurance re AISC 341. Exceptions: 158 pdf_text
1705.12.1.2 1705.12.1.2 Structural steel elements. Special inspections of structural steel elements in the seismic force-resisting systems of buildings and 158 pdf_text
1705.12.2 1705.12.2 Structural wood. For structural wood elements in the seismic force-resisting systems of structures assigned to Seismic Design D: 159 pdf_text
1705.12.3 1705.12.3 Cold-formed steel light-frame construction. For the seismic force-resisting systems of structures assigned to Seismic Design Category C or D, periodic sp inspection shall be required for both: 159 pdf_text
1705.12.4 1705.12.4 Designated seismic systems. For structures assigned to Seismic Design Category C or D, the special inspector shall examine designated s requiring seismic qualification in accordance with Section 13.2.2 of ASCE 7 and verify that the label, anchor mounting conform to the certificate of compliance. 159 pdf_text
1705.12.5 1705.12.5 Architectural components. Periodic special inspection is required for the erection and fastening of exterior cladding, interior and exterio walls and interior and exterior veneer in structures assigned to Seismic Design Category D. Exception: Periodic special inspection is not required for the following: 159 pdf_text
1705.12.5.1 1705.12.5.1 Access floors. Periodic special inspection is required for the anchorage of access floors in structures assigned to Sei Category D. 159 pdf_text
1705.12.6 1705.12.6 Plumbing, mechanical and electrical components. Periodic special inspection of plumbing, mechanical and electrical components shall be required for the follo 159 pdf_text
1705.12.7 1705.12.7 Storage racks. Periodic special inspection is required for the anchorage of storage racks that are 8 feet (2438 mm) or greater structures assigned to Seismic Design Category D. 160 pdf_text
1705.12.8 1705.12.8 Seismic isolation systems. Periodic special inspection shall be provided for seismic isolation systems in seismically isolated structures a Seismic Design Category C or D during the fabrication and installation of isolator units and energy dissipatio 160 pdf_text
1705.12.9 1705.12.9 Cold-formed steel special bolted moment frames. Periodic special inspection shall be provided for the installation of cold-formed steel special bolted moment f seismic force-resisting systems of structures assigned to Seismic Design Category D. 160 pdf_text
1705.8 1705.8, shall be required to confirm the suitable bearing soil and bottom of bell cleanup to remove excess cuttings. A where belled caissons are used, the caisson bell diameter shall be allowed to be oversized by 15 percent, for a minim increase of 6 inches (152 mm) up to a maximum diameter increase of 1 foot (305 mm)." 175 pdf_text
1708.2 1708.2. If the building, structure or portion thereof is found to have inadequate strength, stability or load-bearing cap expected loads, modifications to ensure structural adequacy or the removal of the inadequate construction shall be re 162 pdf_text
171 171. Revise the definition of "penthouse" to read: "PENTHOUSE. An enclosed, rooftop structure used for sheltering mechanical and electrical equipment, tanks, elev related machinery, and vertical shaft openings." 12 pdf_text
172 172. Revise the definition of "permit" to read: "PERMIT. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions." 12 pdf_text
172.1 172.1. Insert the following definition "PERMITTED CONSTRUCTION DOCUMENTS. As defined in Chapter 2 of the Chicago Construction Codes Provisions." 12 pdf_text
173 173. Revise the definition of "person" to read: "PERSON. As defined in Section 1-4-090 of the Municipal Code." 13 pdf_text
174 174. Revise the definition of "physical hazard" to read: "PHYSICAL HAZARD. As defined in Chapter 2 of the Chicago Fire Prevention Code." 13 pdf_text
175 175. Revise the definition of "physiological warning threshold level" to read: "PHYSIOLOGICAL WARNING THRESHOLD LEVEL. As defined in Chapter 2 of the Chicago Fire Preventio 13 pdf_text
176 176. Insert the following definition: "PLANNED DEVELOPMENT. A lot subject to zoning regulations in accordance with Chapter 17-8 of the Chicag Ordinance." 13 pdf_text
177 177. Revise the definition of "platform" to read: "PLATFORM. A raised area used for worship; the presentation of music, plays or other entertainment; the head tab guests; the raised area for lecturers and speakers; boxing and wrestling rings; theater-in-the- round; and similar purpo other than horizontal sliding curtains, there are no overhead hanging curtains, drops, scenery or theatrical effects oth lighting and sound." 13 pdf_text
178 178. Delete the definition of "polypropylene siding." 13 pdf_text
179 179. Insert the following definition: "PORCH. An unheated roofed or covered structure, containing a stairway used for ingress and egress and additiona that is separated from heated areas of the building by a fire-resistance rated exterior wall and unprotected openings. Open porch. A porch that is open to the atmosphere on at least one side. Enclosed porch. Any porch other than an open porch." 13 pdf_text
1791 1791 Tul Atlan 216 pdf_text
18 18. Revise note c to Table 2603.12.2 by replacing "approved" with "engineered." 193 pdf_text
18 18. Revise Section 1107.7 to read: "1107.7 General exceptions. Where specifically permitted by Section 1107.5 or 1107.6, the required number of Type B units is permitted to be red accordance with Sections 1107.7.1 through 1107.7.5. The distribution and features of Type A units may be altered in with Sections 1107.7.6 and 1107.7.7." 115 pdf_text
18 18. Revise Section 1810.3.3.1.4 to read: "1810.3.3.1.4 Allowable shaft resistance. The assumed shaft resistance developed by any uncased cast-in-place deep foundation element shall not exceed one- bearing value of the soil material at minimum depth as set forth in Table 1806.2, up to 500 psf (24 kPa), unless a gre recommended by the registered geotechnical engineer and allowed by the building official on the basis of a geotechn investigation as specified in Section 1803 or a greater value is substantiated by a load test in accordance with Section Shaft resistance and end-bearing resistance shall not be assumed to act simultaneously unless determined by a geotec investigation in accordance with Section 1803." 172 pdf_text
18 18. Elevator emergency or standby power selector switch(es), where emergency or standby power is 80 pdf_text
18 18. Add a new item 5 to Section 903.2.7 to read: "5. A Group M fire area is located in a basement." 69 pdf_text
18 18; IPMC–18; IPSDC–18; IRC–18; ISPSC–18; and IWUIC–18. 217 pdf_text
18 18. Delete the exception to Section 1011.14.2. 98 pdf_text
18 18,0 E-1 NS UL UL 41 pdf_text
18 18. Delete Section 1404.12.3. 130 pdf_text
18 18. Revise Section 2308.6.6.1 to read: "2308.6.6.1 Cripple wall bracing in Seismic Design Categories A, B and C. For the purposes of this section, cripple walls in Seismic Design Categories A, B and C having a stud height exceedi (356 mm) shall be considered to be a story and shall be braced in accordance with Table 2308.6.1. Spacing of edge n required cripple wall bracing shall not exceed 6 inches (152 mm) on center along the foundation plate and the top pla cripple wall. Nail size, nail spacing for field nailing and more restrictive boundary nailing requirements shall be as re elsewhere in the code for the specific bracing material used." 186 pdf_text
18 18. Revise Section 717.6.3 to read: "717.6.3 Nonfire-resistance-rated floor assemblies. Duct systems constructed of materials in accordance with the Chicago Mechanical Code that penetrate nonfire- resis floor assemblies shall be protected by any of the following methods: 62 pdf_text
18 18. Revise Section 1705.13.1.1 by replacing "Seismic Design Category B, C, D, E or F" with "Seismic Design Cate 160 pdf_text
18 18. Revise exception 4 to Section 1029.15 to read: "4. In a building, room or space used for assembly purposes where flexibility of the seating arrangement is an integr design and function of the space and seating is on tiered levels, up to 200 seats shall not be required to be fastened to Plans showing seating, tiers and aisles shall be submitted to the fire code official for review." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 53) 105 pdf_text
18 18. Delete Section 907.2.7.1. 75 pdf_text
18 18. Delete exception 3 to Section 1010.1.9.5. 94 pdf_text
18 18. Revise Section 406.7.2 to read: "406.7.2 Canopies. Canopies under which fuels are dispensed shall have a clear, unobstructed height of not less than 13 feet 6 inches (41 lowest projecting element in the vehicle drive-through area. Canopies and their supports over pumps shall be of nonc materials or construction providing 1-hour fire resistance." 30 pdf_text
18 18. Revise the definition of "area, building" to read: "AREA, BUILDING. See "Building area." 4 pdf_text
18 18. Revise Section 403.4.8.3 to read: "403.4.8.3 Standby power loads. The following are classified as standby power loads: 25 pdf_text
18 18. Revise item 1 in Section 1607.7.2 to read: "1. The actual operational loads, including outrigger reactions and contact areas of the vehicles." 147 pdf_text
18 18. Delete Section 1006.3.3.1. (Amend Coun. J. 7-24-19, p. 3646, § 31; Amend Coun. J. 2-19-20, p. 14473, Art. II, § 42; Amend Coun. J. 10-7-20, p. 2179 Amend Coun. J. 6-25-21, p. 32180, Art. II, § 17; Amend Coun. J. 9-14-21, p. 35949, Art. XV, § 8; Amend Coun. J. 1-26-22, II, § 8) 91 pdf_text
18 18. Revise Section 1507.16 to read: "1507.16 Vegetative roofs, roof gardens and landscaped roofs. Vegetative roofs, roof gardens and landscaped roofs shall comply with the requirements of this chapter and Section 1 137 pdf_text
180 180. Delete the definition of "prestressed masonry." 13 pdf_text
180.1 180.1. Revise the definition of "primary structural frame" by adding Item 5 to read: "5. Bearing walls in light-frame construction." 13 pdf_text
1801 1801 County Rosevil FSAAS–16: Fabric Structures Associated Air Structures 2016" 216 pdf_text
1803 1803. Foundation walls and other walls in which horizontal movement is restricted at the top shall be designed for at Retaining walls free to move and rotate at the top shall be permitted to be designed for active pressure. Design lateral surcharge loads shall be added to the lateral earth pressure load. Foundation walls shall be designed to support the w hydrostatic pressure of undrained backfill unless a drainage system is installed in accordance with Sections 1805.4.2 Where a portion or the whole of the adjacent soil is below a free-water surface, computations shall be based on the w soil diminished by buoyancy, plus full hydrostatic pressure." 151 pdf_text
1804.6 1804.6. Exception: Expansive soil or fill need not be removed to the depth of constant moisture, provided that the co pressure in the expansive soil or fill created by the newly placed fill material and supported structure exceeds pressure." 169 pdf_text
1808.6.2 1808.6.2, the soil or fill shall be stabilized by chemical, dewatering, presaturation or equivalent techniques." 169 pdf_text
181 181. Revise the definition of "private garage" to read: "PRIVATE GARAGE. A building or portion of a building in which not more than five motor vehicles used by the o the building or buildings on the premises are stored or kept, without provisions for repairing or servicing such vehicl inclusive of any attached enclosed walkway." 13 pdf_text
1810.3.3.1.3 1810.3.3.1.3 with consideration for the test type, duration and subsoil. The ultimate axial load capacity shall be deter registered geotechnical engineer with consideration given to tolerable total and differential settlements at design loa accordance with Section 1810.2.3. In subsequent installation of the balance of deep foundation elements, all element deemed to have a supporting capacity equal to that of the control element where such elements are of similar type, si length as the test element; are installed using the same or comparable methods and equipment as the test element; are similar subsoil conditions as the test element; and, for driven elements, where the rate of penetration (for example, n per blow) of such elements is equal to or less than that of the test element driven with the same hammer through a co driving distance." 172 pdf_text
1810.3.3.1.7.1 1810.3.3.1.7.1 Load testing. Deep foundation elements shall develop ultimate load capacities of not less than 2 times the design working l designated load-bearing layers when load testing is used. 173 pdf_text
1810.3.3.1.7.2 1810.3.3.1.7.2 Routine soil testing. Deep foundation elements shall develop ultimate load capacities of not less than 3 times the design working l designated load-bearing layers when routine soil testing is used to determine soil properties. Analysis shall sh layers underlying the designated load-bearing layers do not cause the load- bearing safety factor to be less tha 173 pdf_text
1810.3.3.1.7.3 1810.3.3.1.7.3 In-situ soil testing. Deep foundation elements shall develop ultimate load capacities of not less than 2.5 times the design working designated load-bearing layers when in-situ soil testing is used to determine soil properties. Analysis shall sh layers underlying the designated load-bearing layers do not cause the load-bearing safety factor to be less tha 173 pdf_text
1810.3.9.4.1 1810.3.9.4.1. Where a structure is assigned to Seismic Design Category D, reinforcement shall be provided in accord 174 pdf_text
182 182. Insert the following definition: "PROPERTY LINE. As defined in Chapter 17-17 of the Chicago Zoning Ordinance. Abutting property line. As defined in Chapter 17-17 of the Chicago Zoning Ordinance. Front property line. As defined in Chapter 17-17 of the Chicago Zoning Ordinance. Rear property line. As defined in Chapter 17-17 of the Chicago Zoning Ordinance. Side property line. As defined in Chapter 17-17 of the Chicago Zoning Ordinance." 13 pdf_text
183 183. Insert the following definition: "PUBLIC (for Chapter 11). Any group of people who are users of the building or employees of the building. The te does not include those people who are employed by the owner of a building for the sole purpose of construction or al building during the time in which the building is being constructed or altered." 13 pdf_text
184 184. Insert the following definitions: "PUBLIC FACILITY (for Chapter 11). A public facility includes any of the following: 13 pdf_text
185 185. Revise the definition of "public way" to read: "PUBLIC WAY. As defined in Chapter 17-17 of the Chicago Zoning Ordinance." 14 pdf_text
186 186. Revise the definition of "public-use areas" to read: "PUBLIC-USE AREAS. Interior or exterior rooms or spaces that are made available to the general public. Employe are not public-use areas." 14 pdf_text
187 187. Revise the definition of "pyrophoric" to read: "PYROPHORIC. As defined in Chapter 2 of the Chicago Fire Prevention Code." 14 pdf_text
188 188. Revise the definition of "pyrotechnic composition" to read: "PYROTECHNIC COMPOSITION. As defined in Chapter 2 of the Chicago Fire Prevention Code." 14 pdf_text
189 189. Delete the definition of "record drawings." 14 pdf_text
19 19. Revise Section 406.8.2.2 by replacing "an approved" with "a central." 30 pdf_text
19 19. Revise exception 4 to Section 1010.1.9.5 to read: "4. Where a pair of doors serves a Group B, F or S occupancy, manually operated edge- or surface-mounted permitted on the inactive leaf provided that such inactive leaf is not needed to meet egress capacity requireme inactive leaf shall not contain doorknobs, panic bars or similar operating hardware." 94 pdf_text
19 19. Revise Section 1404.12.4.1 to read: "1404.12.4.1 Installation above sidewalk level. Where thin exterior structural glass veneer is installed above the level of the top of a bulkhead facing, or at a level m inches (914 mm) above the sidewalk level, the mastic cement binding shall be supplemented with nonferrous metal s located in the horizontal joints in every course. Such shelf angles shall be not less than 0.0478-inch (1.2 mm) thick a than 2 inches (51 mm) long, with not less than two angles for each glass unit. Shelf angles shall be secured to the wal with expansion bolts, toggle bolts or by other approved methods." 130 pdf_text
19 19. Revise exception 1 to Section 1705.13.1.1 by replacing "B or C" with "C." 160 pdf_text
19 19. Delete Section 2308.6.6.2. 186 pdf_text
19 19. Revise Section 1810.3.3.1.5 to read: "1810.3.3.1.5 Uplift capacity of a single deep foundation element. Where required by the design, the uplift capacity of a single deep foundation element shall be determined by accepte analysis based on a minimum factor of safety of three or by load tests conducted in accordance with ASTM D3689 o D8169. The maximum allowable uplift load shall not exceed the ultimate load capacity as determined in Section 181 using the results of load tests conducted in accordance with ASTM D3689 or ASTM D8169, divided by a factor of s 172 pdf_text
19 19. Delete exception 2 (and subitems) to Section 907.2.8.1. 75 pdf_text
19 19. Revise the exception to Section 1607.7.3 by deleting "and are approved by the building official." 148 pdf_text
19 19. Revise Section 1107.7.1 to read: "1107.7.1 Structures without elevator service. Where elevator service is not provided in a structure, only the dwelling units and sleeping units that are located on st in Sections 1107.7.1.1 and 1107.7.1.2 are required to be Type B units." 115 pdf_text
19 19. Revise Section 1507.17.2 to read: "1507.17.2 Deck slope. Photovoltaic shingles shall not be installed on low-sloped roofs." 137 pdf_text
19 19. Add a new exception to Section 717.7. 62 pdf_text
19 19. Insert the following definition: "ASSISTIVE LISTENING SYSTEM (ALS). An amplification system using transmitters, receivers and coupling d bypass the acoustical space between a sound source and a listener by means of induction loop, radio frequency, infra wired equipment." 4 pdf_text
19 19. Revise Section 403.4.8.4 to read: "403.4.8.4 Emergency power loads. The following are classified as emergency power loads: 25 pdf_text
19 19. Add new exceptions to Section 903.2.8 to read: "Exceptions: 69 pdf_text
19 19. Revise the second sentence of Section 1011.16 to read: "Permanent ladders shall be constructed in accordance with the Chicago Mechanical Code." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 45; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 23; Amend Coun. J. 1-26-22, II, § 9) 98 pdf_text
19 19. Revise Section 2603.13 to read: "2603.13 Cladding attachment over foam sheathing to wood framing. Cladding shall be specified and installed in accordance with Chapter 14 and the cladding manufacturer’s installation Where used, furring and furring attachments shall be designed to resist design loads determined in accordance with addition, the cladding or furring attachments through foam sheathing to framing shall meet or exceed the minimum f requirements of Section 2603.13.1 or 2603.13.2, or an engineered design for support of cladding weight. Exceptions: 193 pdf_text
19.1 19.1. Revise Section 907.2.8.3 by replacing "smoke alarms" with "smoke alarms, heat alarms and heat detectors" in heading and body. 75 pdf_text
190 190. Revise the definition of "registered design professional" to read: "REGISTERED DESIGN PROFESSIONAL. As defined in Chapter 2 of the Chicago Construction Codes Admini Provisions." 14 pdf_text
191 191. Revise the definition of "registered design professional in responsible charge" to read: "REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. As defined in Chapter 2 of the Chi Construction Codes Administrative Provisions." 14 pdf_text
192 192. Insert the following definition: "REGISTERED GEOTECHNICAL ENGINEER. As defined in Chapter 2 of the Chicago Construction Codes Ad Provisions." 14 pdf_text
193 193. Delete the definition of "religious worship, place of." 14 pdf_text
194 194. Revise the definition of "repair" to read: "REPAIR. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 14 pdf_text
195 195. Revise the definition of "reroofing" to read: "REROOFING. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 14 pdf_text
1950 1950, serving no more than 4 stories above grade plane U Yes Yes Yes For SI: 1 foot = 304.8 mm; 1 inch = 25.4 mm; 1 square foot = 0.0929 m 2. U = any material not less fire resistive than untreated wood or plastic composites that comply with ASTM D7032 and Section 2612, unprotected P = any material, protected with construction providing fire-resistance rating as required for exterior wall P1 = any material, protected with construction providing fire-resistance rating of at least one hour HT = heavy timber construction, complying with Section 2304.11 UNC = noncombustible, unprotected PNC = noncombustible, protected with construction providing fire-resistance rating as required for exterior wall a. Where material type U is allowed, material types P, HT, UNC and PNC shall also be allowed; where material type P is allowed, material types HT, U shall also be allowed; where material type UNC is allowed, material type PNC shall also be allowed. b. Egress balconies shall also comply with Section 1021. Exterior exit stairways and exterior exit ramps shall also comply with Section 1027. 54 pdf_text
196 196. Delete the definition of "residential aircraft hangar." 14 pdf_text
197 197. Revise the definition of "restricted entrance" to read: "RESTRICTED ENTRANCE. An entrance that is made available for common use on a controlled basis, but not p that is not a service entrance. Such entrances shall include, but are not limited to, employee- only entrances." 14 pdf_text
198 198. Revise the definition of "roof recover" to read: "ROOF RECOVER. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 14 pdf_text
199 199. Revise the definition of "roof repair" to read: "ROOF REPAIR. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 14 pdf_text
2 2. Delete Sections 3308.1.1 and 3308.2. 210 pdf_text
2 2. Revise note e to Table 1017.2 to replace "Group R-3 and R-4" with "Group R-3, R-4 and R-5." 100 pdf_text
2 2. Delete all figures and tables included in Section 1608. 148 pdf_text
2 2. In each room used for sleeping purposes. 75 pdf_text
2 2. Revise Section 712.1.3.2 by replacing "approved" with "approved." 59 pdf_text
2 2. Revise section 713.11, including the exception, by deleting "approved." 60 pdf_text
2 2 hours Furnace rooms and boiler rooms in Group I occupancies 46 pdf_text
2 2. Revise item 4 in Section 906.1 to read: "4. On each floor of structures under construction, except Group R-3, R-4 and R-5 occupancies, in accordan Chapter 33." 73 pdf_text
2 2. Revise Section 3104.4 to read: "3104.4 Contents. No furnishings or decorations shall be located in the pedestrian walkway unless approved by the fire code official." 203 pdf_text
2 2. Revise the definition of "accessible means of egress" to read: "ACCESSIBLE MEANS OF EGRESS. A continuous and unobstructed way of egress travel, from any accessible building or facility to a public way, that complies with Section 1009." 3 pdf_text
2 2. Add a new Section 1110.4.16 to read: "1110.4.16 Other recreational facilities. The following recreational facilities shall comply with the Illinois Accessibility Code: 119 pdf_text
2 2. Revise the exceptions to Section 1013.1 to read: "Exceptions: 98 pdf_text
2 2. Brinch-Hansen 90-percent Criterion. 172 pdf_text
2 2. Delete the word "approved" in Section 3004.2. 199 pdf_text
2 2. Equipment, control wiring, power wiring and ductwork shall be located within the enclosure with intake or exhaust directly from and to the outside or through ductwork less than 2-hour fire barriers constructed in accordance with Section 707 or horizontal constructed in accordance with Section 711, or both. 229 pdf_text
2 2 hours Furnace rooms and boiler rooms in other than Group R-5 occupancies 46 pdf_text
2 2. Continuous concrete footings supporting walls of buildings four stories or less above grade plane that are supported on earth or rock where: 157 pdf_text
2 2. Revise the definition of "transient lodging" in Section E102.1 to read: "TRANSIENT LODGING. A building, facility or portion thereof, excluding inpatient medical care facilities and nu that contains one or more dwelling units or sleeping units occupied on a transient basis. Examples of transient lodgin are not limited to, group homes, hotels, homeless shelters, halfway houses and social service lodging. Transient lodg includes housing at a place of education required to comply with Section 1107.6.2.3." 219 pdf_text
2 2. Revise note a to Table 2304.8(4) to delete "approved." 184 pdf_text
2 2. Revise Section 1029.2 by replacing "10 feet (3048 mm)" with "20 feet (6096 mm)." 105 pdf_text
2 2. Delete Section 2409.4.2. CHAPTER 14B-25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTE 189 pdf_text
2 2. The far boundary of a public way adjoining the lot. 9 pdf_text
2 2. Insect screens shall not be required for openings more than 50 feet (15.2 m) above the gro building official determines that unusual insect prevalence exists at the premises." (Added Coun. J. 2-19-20, p. 14473, Art. II, § 60) 127 pdf_text
2 2. Revise Section 2113.5 to read: "2113.5 Corbeling. Masonry chimneys shall not be corbeled more than half of the chimney’s wall thickness from a wall or foundation, n chimney be corbeled from a wall or foundation that is less than 12 inches (305 mm) in thickness unless it projects eq side of the wall, except that on the second story of a two-story building of Group R-5 occupancy, corbeling of chimn exterior of the enclosing walls is permitted to equal the wall thickness. The projection of a single course shall not exc the unit height or one-third of the unit bed depth, whichever is less." 180 pdf_text
2 2. Revise item 1 to Section 2205.2.2 to read: "1. The structure is assigned to Seismic Design Category D except as permitted in ASCE 7, Table 15.4-1." 181 pdf_text
2 2. Where two adjacent street exposures have a combined length not greater than 250 feet (76. department connection shall be allowed." 81 pdf_text
2 2. Delete Section 504.1.1. 36 pdf_text
2 2. Revise Section 1003.4 to read: "1003.4 Slip-resistant surface. Circulation paths of the means of egress shall have a slip-resistant surface that is securely attached. Exception: Where a mat is used on a temporary or seasonal basis, the mat shall be securely attached or have designed to be non-slip." 84 pdf_text
2 2. Add new Sections 3202.1.1.1 through 3202.1.1.4 to read: "3202.1.1.1 Foundations. The portions of foundations above a level 20 feet (6096 mm) below city datum may project into a public way four an inches (114 mm) per foot (305 mm) of depth below sidewalk or alley grade but not more than 36 inches (914 mm). 206 pdf_text
2 2 hours Furnace rooms and boiler rooms in buildings having an occupant load exceeding 200 persons 46 pdf_text
2 2. Delete Table 3306.1. 209 pdf_text
2 2. Openings in the lower roof shall not be located within 15 feet (4572 mm) horizontally of t 58 pdf_text
2 2. Revise Section 311.2 to insert, alphabetically: "Electronic data processing (with only incidental human occupanc 23 pdf_text
2 2 E-2 NS UL 38 pdf_text
2 2. For exterior insulation and finish systems, refer to Section 1407. 193 pdf_text
2 2. The loft shall not be less than 5 feet (1524 mm) in any horizontal dimension. 125 pdf_text
2 2 d H-5 – – – – – – – – – – – – – – – – – – – S = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. NS = Buildings not equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. N = No separation requirement. NP = Not Permitted. a. See Section 420. b. The required separation from parking garages and other motor-vehicle-related occupancies shall be in accordance with Section 406. c. [Reserved.] d. Separation is not required between occupancies of the same classification. e. See Section 422.2 for ambulatory care facilities. f. Occupancy separations that serve to define fire area limits established in Chapter 9 for requiring fire protection systems shall also comply with Section 45 pdf_text
2 2. Add a new Section 1109.5.3 to read: "1109.5.3 Bottle fillers. Where a bottle filler is provided, the bottle filler shall be accessible and located on an accessible route." 118 pdf_text
2 2. Revise Section 508.2.2 to read: "508.2.2 Allowable building height. The allowable building height and number of stories above grade plane of the building containing accessory occupa in accordance with Section 504 for the main occupancy of the building." 44 pdf_text
2 2. Revise the first two sentences of Section 2511.4 to read: "Condition of surfaces shall be as specified in Section 2510.7. Specially prepared gypsum plaster designed for applic concrete surfaces or acoustical plaster shall be permitted." 191 pdf_text
2 2. For habitable spaces other than bedrooms, the basement level, as a whole, shall be provide openings with a net glazed area of at least 4 percent of the aggregate floor area of all habitable basement. 123 pdf_text
2 2. Panels shall not be located in a separate room. 79 pdf_text
2 2. Approved calculations performed in an approved manner. 61 pdf_text
2 2. Revise Table 716.1(2) by deleting the rows for "Horizontal exits in fire walls" and the rows for assemblies with a assembly rating of 0.5 hours. 61 pdf_text
2 2. Revise the numbered portion of Section 703.3 to read: "1. Fire-resistance designs documented in a test report prepared by an approved agency or test results comp Online Certifications Directory, Intertek Directory of Building Products, GA 600 or another approved source. 51 pdf_text
2 2. Revise row 4 of Table 1607.1 by inserting an entry for "Dressing rooms" with a value of "40." 146 pdf_text
2 2. Interior balconies within Group A occupancies, mezzanines and equipment platforms that 59 pdf_text
2 2. Serving a single dwelling unit. 97 pdf_text
2 2. Revise Section 901.3 to read: "901.3 Modifications. It is unlawful for any person to remove, modify or disable for more than 24 hours any automatic sprinkler system, a extinguishing system, standpipe system or fire pump installed or maintained under the provisions of this code or the Prevention Code without a permit from the fire code official. It is unlawful for any person to remove, modify or disa than 24 hours a fire alarm and detection system, smoke control system or carbon monoxide detection system without 66 pdf_text
2 2. Group R-3 and R-5 occupancies. 152 pdf_text
2 2. Delete exception 8 to Section 1010.1.1. 92 pdf_text
2 2. Revise exception 1 to Section 2610.2 to read: "1. Curbs shall not be required for skylights used on roofs having a minimum slope of three units vertical in horizontal (25-percent slope) in occupancies in Group R-3 or R-5 and on buildings with a nonclassified roof 195 pdf_text
2 2. Delete Section 1502.2. 134 pdf_text
2 2. Revise Section 3102.3, excluding its exception, to read: "3102.3 Type of construction. Noncombustible membrane structures shall be classified as Type IIB construction. Noncombustible frame or cable-s structures covered by a membrane in accordance with Section 3102.3.1 shall be classified as Type IIB construction. membrane structures shall be classified as Type VB construction." 201 pdf_text
2 2. Recommended center-to-center spacing of deep foundation elements. 163 pdf_text
2 2. Revise Section 2603.1 by replacing "foam plastic insulation" with "foam plastic insulation (including insulated p foam plastic insulation)." 192 pdf_text
2 2. Revise Section 1002.2 to read: "1002.2 Fire safety and evacuation plans. Fire safety and evacuation plans shall be provided for all occupancies and buildings where required by the Chicago Code. Such fire safety and evacuation plans shall comply with the applicable provisions of the Chicago Fire Prevent (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 38) 84 pdf_text
2 2. Stories, mezzanines or occupiable rooftops that do not contain accessible elements or other determined by Section 1107 or 1108 are not required to be served by an accessible route from level. 110 pdf_text
2 2. Revise Section 914.2 to read: "914.2 Equipment room identification. Fire protection equipment shall be clearly identified. Rooms containing controls for air-conditioning systems, sprinkl valves or other fire detection, suppression or control elements shall be identified for the use of the fire department. Si to identify fire protection equipment and equipment location shall be constructed of durable materials, permanently i readily visible." 81 pdf_text
2 2. Revise the exceptions to Section 1202.2.1 to read: "Exception: The net free cross-ventilation area shall be permitted to be reduced to 1/300 provided at least 40 percent than 50 percent of the required venting area is provided by ventilators located in the upper portion of the attic or raft ventilators shall be located not more than 3 feet (914 mm) below the ridge or highest point of the space, measured ve the balance of the ventilation provided by eave or cornice vents. Where the location of wall or roof framing members the installation of upper ventilators, installation more than 3 feet (914 mm) below the ridge or highest point of the sp permitted." 120 pdf_text
2 2. Combustible exterior wall coverings shall be limited to 40 feet (12 192 mm) in height above grad Exceptions: 131 pdf_text
2 2. Group I-1, R-1, R-2, R-3, R-4 and R-5 dwelling units and sleeping units shall not be classified as a occupancies and shall be separated from other dwelling or sleeping units and from other occupancies them in accordance with the requirements of Section 420. 44 pdf_text
2 2. Revise the exceptions to 1505.2 by replacing "decks" with "roof decks." 136 pdf_text
2 2. Interior exit stairways and ramps and exit passageways: A/Aw = 0.00035 221 pdf_text
2 2. A facility having three or fewer children receiving such day care shall be classified as part of the p occupancy. 20 pdf_text
2 2. Any canopy covering, other than textiles, shall have a flame spread index not greater than 25 whe accordance with ASTM E84 or UL 723 in the form intended for use. 218 pdf_text
2 2. For all structures on a zoning lot not exceeding 10,000 square feet (929 m2) in area, "grade," deter accordance with Section 17-17-0265 of the Chicago Zoning Ordinance, shall be allowed to be used as 17 pdf_text
2 2. Revise Section 704.3 to read: 51 pdf_text
2 2 hours in Group A, E, I and R occupancies. Incinerator rooms 46 pdf_text
2 2. The top of the exterior glazing shall be no less than 9 feet (2743 m) above the finished floo 123 pdf_text
2 2. Date the fabric was last treated with flame-retardant solution, if applicable. 202 pdf_text
2 2. Parking facilities in accordance with Section 406.9. 76 pdf_text
2 2. A room or space where sprinklers are considered undesirable because of the nature of the contents approved by the fire code official. 70 pdf_text
2 2. Delete the last sentence of Section 2111.4. 179 pdf_text
2 2. The fire area has an occupant load of 300 or more. 68 pdf_text
2 2. Piping systems regulated by the Chicago Fuel Gas Code. 213 pdf_text
2 2. Revise Section 1027.5 to read: "1027.5 Location. Exterior exit stairways and exterior exit ramps shall have a minimum separation distance of 10 feet (3048 mm) meas angles from the exterior edge of the stairway or ramps, including landings, to: 104 pdf_text
2 2. Add an exception to Section 2512.9 to read: "Exception: Acrylic-based or siliconized acrylic-based finish coat systems manufactured for application as a finish c Portland cement based exterior stucco or plaster assemblies shall be allowed as a finish coat." 191 pdf_text
2 2. Exterior insulation and finish systems (EIFS) complying with Section 1407. 131 pdf_text
2 2. Revise Section 2303.1.3 to read: "2303.1.3 Structural glued-laminated timber. Structural glued-laminated timbers shall be manufactured and identified as required in ANSI/AITC A 190.1 and ASTM D3 183 pdf_text
2 2. Shops and storerooms not exceeding 1,000 square feet (93 m2) in a building not exceeding one sto plane." 70 pdf_text
2 2. Replace Table 803.13 as shown: TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY k GROUP SPRINKLERED l NONSPRINKLERED Interior exit stairways and ramps, exit passageways and interior portions of the exit discharge a Corridors and enclosure for exit access stairways and ramps Rooms and enclosed spaces c Interior exit stairways and ramps, exit passageways and interior portions of the exit discharge a Corridors and enclosure for exit access stairways and ramps en GROUP SPRINKLERED l NONSPRINKLERED Interior exit stairways and ramps, exit passageways and interior portions of the exit discharge a Corridors and enclosure for exit access stairways and ramps Rooms and enclosed spaces c Interior exit stairways and ramps, exit passageways and interior portions of the exit discharge a Corridors and enclosure for exit access stairways and ramps en A-1, A-2 A B C A A A-3, A-4, A-5 A B C A A B, E, M, R-1 A C m C A B R-4 B C C A B F A C C A C H A B C g A A I-1 A C C A B I-2 A B B h, i A A I-3 A A j C A A I-4 A B B h, i A A R-2 A C C A B R-3, R-5 C C C C C S A C C A B U No restrictions No restrictions 64 pdf_text
2 2. In Group R-3 and R-5 occupancies a flight of stairs may have a vertical rise not greater than 151 i mm) between floor levels or landings." 97 pdf_text
2 2. Throughout buildings containing Group E occupancies owned by, operated by or constructed with a governmental unit. 68 pdf_text
2 2. More than 12 feet (3658 mm) above the adjacent finished ground level at any point." 15 pdf_text
2 2. Revise Sections 1209.2.1, 1209.2.2 and 1209.2.3 by replacing "a smooth, hard, nonabsorbent" with "an easily-cle nonabsorbent." 126 pdf_text
2 2. Dwelling units and sleeping units in Group R-1 occupancies shall comply with Section 11 not be considered in determining the number of units in a planned development for purposes o 116 pdf_text
2 2. Add a new Section 3304.3 to read: "3304.3 Fencing of excavation work. Where excavation work to any depth will occur within 5 feet (1524 mm) of a walkway on public or private property, fencing, not less than 4 feet (1219 mm) in height shall be erected around the area of excavation. Such fencing shall b supported to prevent it from collapsing due to wind. Where the depth of excavation work exceeds 30 inches (762 m shall meet the requirements for guards in Chapters 10 and 16. No person shall remove or open a required fence exce necessary delivery and removal of materials, tools and equipment or passage of workers, inspectors or other persons presence is required at the site." 209 pdf_text
2 2. Camping facilities. 119 pdf_text
2 2. Membrane structures that are erected on occupiable rooftops, exterior balconies, decks or structures for any period of time shall be regulated as permanent membrane structures in acco 201 pdf_text
2 2. The restrictions on door swing shall not apply to doors within individual dwelling units an of Group R-2, R-3 and R-5 occupancies. 87 pdf_text
2 2. Revise Section 1806.2 to read: "1806.2 Presumptive load-bearing values. 165 pdf_text
2 2. Revise Section 404.3 to read: "404.3 Automatic sprinkler protection. An automatic sprinkler system shall be installed throughout the entire building. Exception: Where the ceiling of the atrium is more than 55 feet (16 764 mm) above the floor, sprinkler prote ceiling of the atrium is not required." 27 pdf_text
2 2. Revise Section 903.2 by deleting "Approved." 67 pdf_text
2 2. Elevator car lighting. 25 pdf_text
2 2. Delete Section 1706.2. 161 pdf_text
2 2. Main exterior exit doors or gates that are obviously and clearly identifiable as exits need not have where approved by the fire code official. 98 pdf_text
2 2. The fire department communications system. 80 pdf_text
2 2. Revise Section 916.4 to read: "916.4 Power connections. Gas detection systems shall be permanently connected to the building electrical power supply." 82 pdf_text
2 2. Add an exception to item 6 in Section 603.1 to read: "Exception: Combustible millwork shall not be permitted in exterior wall openings that are within 5 feet (1524 mm) and 3 feet (914 mm) vertically of an opening in an adjacent story." 49 pdf_text
2 2. Revise Section 1407.5 to read: 132 pdf_text
2 2. Revise Table 2308.2.1 to read: TABLE 2308.2.1 ALLOWABLE STORY HEIGHT 185 pdf_text
2 2. The toilet room shall not directly connect to any habitable space. 102 pdf_text
2 2. Revise Section 722.5.2.1 by replacing "approved" with "tested." 63 pdf_text
2 2. Recommended specifications for material to be used as compacted fill." 164 pdf_text
2 2. Add a new exception following Section 2103.1.1 to read: "Exception: Undamaged masonry units may be reused on the same site for the same purpose without needing to con requirements for new masonry units." 179 pdf_text
2 2. Revise Section 1709.5.1 by replacing "approved labeling agency" with "approved agency." CHAPTER 14B-18 SOILS AND FOUNDATIONS 162 pdf_text
2 2. Revise Section D101.1 to read: "D101.1 Scope. The fire limits shall include that portion of the city bounded by: Division Street; Lake Michigan; the Stevenson Expr CTA red line right-of-way; Cermak Road; the Metra SouthWest Service right-of-way; the South Branch of the Chica Street; the Dan Ryan Expressway; Roosevelt Road; Halsted Street, the Eisenhower Expressway; Ashland Avenue; O Hubbard Street; the Kennedy Expressway; Ogden Avenue; Chicago Avenue; North Halsted Street; and the North Br 218 pdf_text
2 2. Delete Section 911.1.2. 80 pdf_text
2 2. Revise Section 907.1.2 to read: "907.1.2 Fire alarm shop drawings. Shop drawings for fire alarm systems shall be prepared in accordance with NFPA 72 and submitted for a separate pe system installation." 73 pdf_text
2 2. The heat alarm or heat detector shall either be interconnected with the smoke alarms within the att 75 pdf_text
2 2. The structure is a high-rise building. 157 pdf_text
2 2. Aisle accessways in Group A. 92 pdf_text
2 2. Revise the first sentence of exception 5 to Section 2405.4 to read: "Screens shall not be required for laminated glass with a 15-mil (0.38 mm) polyvinyl butyral (or equivalent) interlay individual dwelling units in Groups R-2, R-3 and R-5 within the following limits:" 188 pdf_text
2 2. Revise the last sentence of Section 1908.5 to read: "Reports of preconstruction tests shall be made available to the building official as specified in Section 1704.5." 177 pdf_text
2 2. Where a concrete roof deck is used and the above-deck thermal insulation is covered with covering." 138 pdf_text
2 2. In structures assigned to Seismic Design Category D, special inspections of steel elements are not required for seismic force-resisting systems where design other than AISC 341 is permitted by ASCE 7, Table 15.4-1. Special inspection accordance with the applicable referenced standard listed in ASCE 7, Table 15. 159 pdf_text
2 2. No more than 50 percent of the floor area of the first story above grade plane is allowed t Group A, B or M occupancies that exit directly to a public way, are provided with an automati system in accordance with Section 903.3.1.1 or 903.3.1.2 and are separated from the remainde structure by fire barriers and horizontal assemblies having a fire-resistance rating of not less t 31 pdf_text
2 2. Delete the exception to Section 1024.6. 103 pdf_text
2 2. Revise section 3003.3 to read: "3003.3 Standardized fire service elevator keys. All elevators shall be equipped to operate with a standardized fire service elevator key in accordance with the Chicag Device Code." 199 pdf_text
2 2. Revise exception 1 to Section 1005.3.1 by deleting "and an emergency voice/alarm communication system in acc 87 pdf_text
2 2. Brick veneer with a clear airspace as specified in this code. 129 pdf_text
2 2-hour fire barriers constructed in accordance with Section 707 or horizontal assembli in accordance with Section 711, or both. Exceptions: 229 pdf_text
2 2. Revise the first sentence of Section 709.4.2 to read: "Smoke-barrier walls used to enclose areas of refuge in accordance with Section 1009.6.4, shall form an effective m enclosure that terminates at a fire barrier wall having a level of fire protection rating not less than 1 hour, another sm wall or an outside wall." 59 pdf_text
2 2. Tubing and connected devices shall be completely enclosed within a galvanized or steel enclosure having a minimum thickness of 0.0296 inch (0.7534 mm) (No. 22 gage enclosure shall be by copper tubing with a protective grommet of neoprene or Teflon o brass compression to male barbed adapter. 225 pdf_text
2 2. For other than fire service access elevators, in buildings four stories or less above grade plane equ automatic sprinkler system where machine room, machinery spaces, control rooms and control spaces and do not have openings to the hoistway enclosure they serve, the machine room, machinery spaces, and control spaces are not required to be fire- resistance rated." 199 pdf_text
2 2. Revise Section 912.2.1 by deleting "approved." 81 pdf_text
2 2. Delete Section 2506.2.1. 190 pdf_text
2 2. Revise Table 1004.5 by adding a new entry under "Assembly without fixed seats" to read: "Outdoor areas (greater than 400 square feet) | 20 net" 85 pdf_text
2 2. Elevator lobbies. 76 pdf_text
2 2. Group I-1, R-1, R-2, R-3, R-4 and R-5 dwelling units and sleeping units shall be separated from ot or sleeping units and from other occupancies contiguous to them in accordance with the requirements 45 pdf_text
2 2. Revise the exception to Section 905.3 to read: "Exception: Standpipe systems are not required in Group R-2, R-3, R-4 and R-5 occupancies not more than four sto grade plane." 72 pdf_text
2 2 hours or 1 hour and provide automatic sprinkler sys Storage rooms used for combustible material in buildings with an exhibition area 46 pdf_text
2 2. The basic design wind speed, V, for use in the design of Risk Category II structures shall be 107 149 pdf_text
2 2. Revise the exceptions to Section 1907.1 by replacing "Group R-3" with "Group R-3 or R-5." (Amend Coun. J. 6-25-21, p. 32180, Art. II, § 25) 177 pdf_text
2 2. Rooms, areas and spaces in the first story above grade plane complying with Section 1006.2 with discharge directly to the exterior at the level of exit discharge, are permitted to have one exit. 89 pdf_text
2 2. Revise the first sentence of Section 1507.1.2 to read: "At eaves, an ice barrier shall be installed for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slat type shingles, wood shingles and wood shakes." 136 pdf_text
2 2. Revise Section 2702.1.2 to read: "2702.1.3 Installation. Emergency power systems and standby power systems required by this code, the Chicago Electrical Code or the Chi Prevention Code shall be installed in accordance with the Chicago Electrical Code." 196 pdf_text
2 2. If the volume of the atrium exceeds 600,000 cubic feet (16 990 m 3), the exhaust system shall pro than 4 air changes per hour. 78 pdf_text
2 2. Located within the area of an auditorium in which the vertical viewing angl measured to the too of the screen, are from the 40th to the 100th percentile of v angles for all seats as ranked from the seats in the first row (1st percentile) to se row (100th percentile)." 109 pdf_text
2 2. Foam plastic used as interior wall or ceiling finish or interior trim in plenum-served spaces flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in ac ASTM E84 or UL 723 at the maximum thickness and density intended for use, where it is sep airflow in the plenum by corrosion-resistant steel having a base metal thickness of not less tha (0.4 mm). 193 pdf_text
2 2. Revise Section 312.1.1 to read: "312.1.1 Greenhouses. Greenhouses not classified as another occupancy shall be classified as Use Group U." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 7) CHAPTER 14B-4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCU 23 pdf_text
2 2. Revise Section 1901.5 by replacing "Seismic Design Category D, E or F" with "Seismic Design Category D." 176 pdf_text
2 2. Delete item 4 in the exception to Section 715.1. 61 pdf_text
2 2. In Group I-4 occupancies all living and sleeping rooms for persons receiving custodial car provided with natural light in accordance with Section 1204.2 and artificial light in accordance 122 pdf_text
2 2. Storm and screen doors serving individual dwelling units in Groups R-2, R-3 and R-5 need not be inches (1219 mm) from the other door. 94 pdf_text
2 2. Revise the last sentence of Section 2403.5 to read: "Where other glass types are used, the design shall be approved by the building official." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 86) 187 pdf_text
2 2. Revise exception 1.2 to Section 714.4.2 by deleting "cellulose loose fill." 60 pdf_text
2 2 hours and provide automatic sprinkler system 46 pdf_text
2 2. Where doors are allowed by Section 1010.1.5." 97 pdf_text
2 2 Not Permitted 61 pdf_text
2 2. Delete figures accompanying Section 1611.1. 151 pdf_text
2 2. Revise note g to Table 2306.3(1) by replacing "Seismic Design Category D, E or F" with "Seismic Design Categ 185 pdf_text
2 2. Delete Section 1001.2. 84 pdf_text
2 2. Revise items 1 and 2 in Section 419.1.1 to read: "1. The live/work unit shall be not less than 800 square feet (74.3 m2) and not greater than 3,000 square feet (279 m2 area. 33 pdf_text
2 2. Delete Section 3302.2. 208 pdf_text
2 2. Revise Section 2207.5 by replacing "approved construction documents" with "permitted construction documents. 181 pdf_text
2 2. Roofs with a minimum of 15 pounds per square foot (0.72 kN/m 2 ) of ballast insta entire roof area to resist wind uplift shall have a three-year-aged solar reflectance value greater. 143 pdf_text
2 2. Within Type B units. 93 pdf_text
2 2. Group I occupancies in buildings with more than three stories. 77 pdf_text
2 2. Revise item 3 to section 2608.2, including its exception, to read: "3. Light-transmitting plastics shall not be installed more than 40 feet (12 190 mm) above grade plane." 195 pdf_text
2 2. Delete Section 717.2.1. 62 pdf_text
2 2. Delete exception 2 to Section 412.2.3.2. 32 pdf_text
2 2. In dwelling units in Group I-1, R-2, R-3, and R-5 occupancies, natural ventilation in accor 120 pdf_text
2 2. Revise the exception to Section 1026.4.2 by replacing the initial "The" with "In Group I-3, the". (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 50) 103 pdf_text
2 2. Only the AUTO position of each three-position fire-fighter’s control panel switch shall all or manual control action from other control points within the building. The AUTO position sh NORMAL, nonemergency, building control position. Where a fire fighter’s control panel is in position, the actual status of the device (on, off, open, closed) shall continue to be indicated by indicator described in Section S101.16.1. Where directed by an automatic signal to assume an condition, the NORMAL position shall become the emergency condition for that device or gro within the zone. Control actions shall not require the smoke control system to assume more th configuration at any one time. S101.17 System response time. Smoke-control system activation shall be initiated immediately after receipt of an appropriate automatic or manual a command. Smoke control systems shall activate individual components (such as dampers and fans) in the sequence n prevent physical damage to the fans, dampers, ducts and other equipment. For purposes of smoke control, the fire fig 226 pdf_text
2 2. Delete the second sentence of Section 602.3. 49 pdf_text
2 2. In Group I-3 facilities, an accessible route is not required to connect stories or mezzanines Accessible units, all common use areas serving Accessible units and all public use areas are on route. 112 pdf_text
2 2. Revise Section 303.3 to insert, alphabetically: "Dance halls (including food or drink consumption)." 19 pdf_text
2 2. Revise Section 503.1.1 to read: "503.1.1 Special industrial occupancies. Single-story buildings and structures of Type I or II construction used exclusively for the production and distribution gas or steam or for low-hazard industrial processes that require large areas and unusual building heights to accommo or special machinery and equipment shall be exempt from the building height and building area limitations specified 36 pdf_text
2 2. Prescriptive designs of fire-resistance-rated building elements, components or assemblies as prescribed in 51 pdf_text
2 2. Recommended specifications for the CLSM." 164 pdf_text
2 2. Materials that meet a peak rate of heat release not exceeding 300 kW/ m2 when tested in ac ASTM E1354 at an incident heat flux of 50 kW/m2 in the horizontal orientation. 212 pdf_text
2 2. In Type B units, where Exception 5 to Section 1010.1.5 permits a 4-inch (102 mm) elevation chan the threshold height on the exterior side of the door shall not exceed 4 3/4 inches (120 mm) in height exterior deck, patio or exterior balcony for sliding doors or 4 1/2 inches (114 mm) above the exterior exterior balcony for other doors." 94 pdf_text
2 2. Delete Section 1807.1.4. 168 pdf_text
2 2. Revise the exception to Section 1014.3 by replacing "Group R-3" with "Group R-3 or R-5." 99 pdf_text
2 2. Revise note b to Table 2508.6 to read: "Values shall be reduced 50 percent in Seismic Design Category D." 190 pdf_text
2 2. Revise Section 1509.2 to replace "decks" with "roof decks" and "an approved" with "a." 138 pdf_text
2 2. The nonresidential area shall be not more than 50 percent of the area of each live/work unit." 33 pdf_text
2 2. Spiral stairways in accordance with Section 1011.10. 96 pdf_text
2 2. Geotechnical investigations are not required for alterations and additions that do not require new and do not result in an increase in loads exceeding 5 percent of the existing foundation design capacit 163 pdf_text
2 2. Nonprestressed reinforcement in compression 171 pdf_text
2 2. Revise Section 1704.2.1 to read: "1704.2.1 Special inspection agency qualifications. Prior to the start of construction, the special inspection agencies shall provide written documentation to the owner de the competence and relevant experience or training of the special inspectors who will perform the special inspection during construction. Experience or training shall be considered to be relevant where the documented experience or tr 155 pdf_text
2 2. Revise Section 915.1.1 by replacing "through 915.1.6" with "through 915.1.5." 81 pdf_text
2 2. Mechanical systems associated with hoistway pressurization or cooling." 198 pdf_text
2 2. Delete items 4 and 5 in the exception to Section 403.1. 24 pdf_text
2 2. Historic buildings." (Amend Coun. J. 9-21-22, p. 52080, Art. II, § 6) 143 pdf_text
2 2 hours and provide automatic sprinkler system Paint shops, not classified as Group H, located in occupancies other than Group F 46 pdf_text
2 2. Exterior cladding and interior and exterior veneer weighing 5 psf (24.5 N/ m2) or le 159 pdf_text
2 2. The space containing the domestic cooking facilities shall be arranged so as not to obstruct required exit. 34 pdf_text
2 2. Fans, dampers and other operating equipment in their off or closed status – RED. 226 pdf_text
2 2. Revise Section 3303.3 to read: "3303.3 Means of egress. A horizontal exit shall not be destroyed unless and until a substitute means of egress has been provided." 208 pdf_text
2 2 NP NP 45 pdf_text
2 2 F-1 NS UL 38 pdf_text
2 2. Revise Section 411.6 and its subsections to read: "411.6 Exit marking. Exit signs shall be installed at the required exit or exit access doorways of amusement buildings in accordance with t 32 pdf_text
2 2. In kitchens, the lowest shelf of a storage facility mounted above a work surface co 109 pdf_text
2 2. Delete Section 1208.2. 126 pdf_text
2 2. Alternative elevations for kitchens in units required to comply with Section 1107.8.2 showing acc after adaptation. 116 pdf_text
2 2. For bases and flanges, 1 inch (25 mm) and reinforced with fillets and brackets. 182 pdf_text
2 2. Walls in which the water-resistive barrier or air barrier required by the Chicago Energy C Code is the only combustible component and the water-resistive barrier or air barrier required Chicago Energy Conservation Code has a peak heat release rate of less than 150 kW/m2, a tot of less than 20 MJ/m2 and an effective heat of combustion of less than 18 MJ/kg as determine with ASTM E1354 and has a flame spread index of 25 or less and a smoke-developed index of determined in accordance with ASTM E84 or UL 723. The ASTM E1354 test shall be conduc specimens at the thickness intended for use, in the horizontal orientation and at an incident rad of 50 kW/m2." 128 pdf_text
2 2. Decks, patios and walkways accessory to Group R-5 occupancies or individual dwelling units that change in elevation where the landing depth on each side of the change of elevation is greater than wh for a landing do not require handrails. 97 pdf_text
2 2. On any side of an exterior exit stairway or exterior exit ramp protected by a solid wall wit resistance rating of at least one hour that extends at least 3 feet (914 mm) beyond the exterior adjacent sides and 8 feet (2438 mm) above the highest landing, the separation distance may be feet (914 mm). 104 pdf_text
2 2. Revise Section 718.2.1.3 to read: "718.2.1.3 Loose-fill insulation material. Loose-fill insulation material, insulating foam sealants and caulk materials shall not be used as a fireblock." 63 pdf_text
2 2. Revise Section 3002.3, including its exception, to read: "3002.3 Emergency signs. A pictorial sign shall be posted adjacent to each elevator call station on all floors instructing occupants to use the exit not to use the elevators in case of fire." 198 pdf_text
2 2. Aggregate, gravel or stone used as ballast." 135 pdf_text
2 2. Buildings on the same lot that are considered as portions of one building in accordance wit 56 pdf_text
2 2. Walking surfaces listed as a Class A roof assembly or a Class A roof covering inst noncombustible roof assembly. 141 pdf_text
2 2. Buildings of Group R occupancy with no more than 4 stories above grade plane. 134 pdf_text
2 2. Revise the exceptions to Section 420.2 to read: "Exception: Within Group R congregate living facilities, where sleeping units are arranged in suites containing no sleeping units each, walls between the sleeping units and shared living spaces are not required to be constructed as fir 34 pdf_text
2 2. The annular space around the penetrating duct is protected with a noncombustible material that re passage of flame and the products of combustion. Exception: Fire dampers are not required in ducts within individual residential dwelling units." 62 pdf_text
2 2. Revise item 4 in Section 806.1 to read: "4. The permissible amount of decorative live vegetation and noncombustible decorative materials shall not 65 pdf_text
2 2. Replace each occurrence of "International Building Code" with "Chicago Building Code." 2 pdf_text
2 2. Testing of all components bypassed from the preprogrammed weekly test shall be i with the Chicago Fire Prevention Code. S101.12.2 Wiring. In addition to meeting requirements of the Chicago Electrical Code, all wiring, regardless of voltage, shall be within continuous raceways. S101.12.3 Activation. Smoke control systems shall be activated in accordance with this section. S101.12.3.1 Pressurization, airflow or exhaust method. Mechanical smoke control systems using the pressurization, airflow or exhaust method shall have co automatic control. S101.12.3.2 Passive method. Passive smoke control systems actuated by spot-type detectors listed for releasing service shall be per S101.12.4 Automatic control. Where completely automatic control is required or used, the automatic-control sequences shall be initiated fr appropriately zoned automatic sprinkler system complying with Section 903.3.1.1, manual controls provided access for the fire department and any smoke detectors required by engineering analysis. S101.13 Control air tubing. Control air tubing shall be of sufficient size to meet the required response times. Tubing shall be flushed clean and dr connections and shall be adequately supported and protected from damage. Tubing passing through concrete or maso sleeved and protected from abrasion and electrolytic action. S101.13.1 Materials. Control-air tubing shall be hard-drawn copper, Type L, ACR in accordance with ASTM B42, ASTM B43, A ASTM B88, ASTM B251 and ASTM B280. Fi 225 pdf_text
2 2. Revise Section 1007.1.1 to read: "1007.1.1 Two exits or exit access doorways. Where two exits, exit access doorways, exit access stairways or exit access ramps, or any combination thereof, are re any portion of the exit access, they shall be placed a distance apart equal to not less than one- half of the length of th overall diagonal dimension of the building or area to be served measured in a straight line between them. Exceptions: 91 pdf_text
2 2. The veneer is attached to or furred from a noncombustible backing that is fire-resistance rated as required provisions of this code. 129 pdf_text
2 2. Skylights that are unobstructed to the sky are not required to open directly onto a p or court. 123 pdf_text
2 2. Revise items 1 and 2 of Section 2606.7 to read: "1. Group A with an occupant load of 300 or more. 194 pdf_text
2 2. Revise item 7 in Section 1019.3 to delete "smoke-protected or." 101 pdf_text
2 2. Revise Section 1103.2.3 to read: "1103.2.3 Group R-5. Group R-5 occupancies, their accessory structures and their associated sites and facilities are not required to comply 109 pdf_text
2 2. Revise exception 1 to Section 1104.2 to read: "1. An accessible route is not required between accessible buildings, accessible facilities, accessible elements and spaces where all of the following conditions are met: 110 pdf_text
2 2. Delete exception 3 to Section 1023.3.1. 103 pdf_text
2 2. A stair with a single riser or with two risers and a tread is permitted at locations not required to be accessi 85 pdf_text
2 2. Revise exception 4 to Section 2406.4.2 to read: "4. Glazing in walls on the latch side of and perpendicular to the plane of the door in a closed position in buildings occupancy or within dwelling units and sleeping units in other Group R occupancies." 188 pdf_text
2 2. The triangular openings at the open sides of a stair, formed by the riser, tread and bottom rail shal passage of a sphere 6 inches (152 mm) in diameter. 99 pdf_text
2 2. Fire walls shall be permitted to terminate at the interior surface of noncombustible exterior sheath siding or other noncombustible exterior finishes provided that the sheathing, siding or other exterior n finish extends a horizontal distance of not less than 4 feet (1220 mm) on both sides of the fire wall. U openings are not permitted within the horizontal distance of 4 feet (1220 mm). 57 pdf_text
2 2. Revise item 5 in Section 1111.2 by deleting "approved." CHAPTER 14B-12 INTERIOR ENVIRONMENT 119 pdf_text
2 2. be equipped with doors, movable panels, or louvers that are operable from within t room and that when fully open provide a net open area of not less than 10 percent of th the remote room or space, but not less than 30 square feet (2.8 m2). The openable area of the openings to the outdoors shall be based on the total floor area being ventilate 121 pdf_text
2 2. Fixed openings between smoke zones that are protected utilizing the airflow metho 222 pdf_text
2 2. Delete item 3 in the third paragraph of Section 1605.1. 146 pdf_text
2 2. Limited area systems in accordance with Section 903.3.8. 67 pdf_text
2 2. In each elevator machine room, machinery space, control room and control space and in elevator l 76 pdf_text
2 2. Revise exception 1 to Section 910.2 by deleting "approved." 79 pdf_text
2 2. Delete the exception to Section 711.2.4.3. 59 pdf_text
2 2. Where a building is equipped throughout with an automatic sprinkler system in accordanc 91 pdf_text
2 2. Means of egress components only serving occupancies that are open to the atmosp open parking garages or Group A-5 occupancies. 103 pdf_text
2 2 NP NP NP 45 pdf_text
2 2. Occupancies in Group I-3 or in Group F, H and S occupancies other than areas accessible t The size of the opening in the riser is not restricted. 96 pdf_text
2 2. Building height shall be measured to the top of a parapet wall that exceeds 42 inches (1067 the highest point of a low-sloped roof or occupiable rooftop. 17 pdf_text
2 2. For applications subject to an exception to Section 1104.4. 118 pdf_text
2 2. OPEN-AUTO-CLOSE control over individual dampers relating to smoke control and that from other sources within the building. 226 pdf_text
2 2. Replace Table 506.2 as shown: TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET a, b OCCUPANCY CLASSIFICATION SEE NOTES CONSTRUCTION TYPE TYPE I TYPE II TYPE III TYPE IV A B A B A B HT OCCUPANCY CLASSIFICATION SEE NOTES CONSTRUCTION TYPE TYPE I TYPE II TYPE III TYPE IV A B A B A B HT A A-1 NS UL UL 41 pdf_text
2 2. Revise the exception to Section 1008.2.1 to read: "Exception: For auditoriums, theaters, concert or opera halls, galleries and similar assembly occupancies, the illumi walking surface is permitted to be reduced during performances or exhibits to not less than 0.1 footcandle (1 lux) at t surface, provided that the required illumination is automatically restored upon failure of normal power or activation premises’ fire alarm system." 92 pdf_text
2 2. Within a dwelling unit or sleeping unit in a Group R occupancy, habitable spaces and hall a ceiling height of not less than 7 feet (2134 mm) above the finished floor. Bathrooms, toilet r laundry rooms shall have a ceiling height of not less than 6 feet 8 inches (2032 mm) above the 125 pdf_text
2 2. Revise Section 1810.2.1 by replacing "registered design professional" with "registered geotechnical engineer." 170 pdf_text
2 2. Spaces within dwelling units and sleeping units, other than Accessible units and Type A units, and egress from a single unit shall comply with Section 1207." 84 pdf_text
2 2. Revise note i to Table 307.1(1) to delete "Section 603.3.2 of." 20 pdf_text
2 2. Where the parking garage has a storage capacity of more than 20 vehicles and is located beneath o occupancies. 69 pdf_text
2 2. Revise Section 3201.2 by replacing "lot line" with "property line." 205 pdf_text
2 2. Revise Section 407.4 by deleting "Sections 403 and 404 of." 31 pdf_text
2 2. Revise Section 719.4 by deleting "approved." 63 pdf_text
2 2. Unusual design applications of materials described in this code. 157 pdf_text
2 2. Revise Section 1408.5 to read: "1408.5 Approval. Results of tests or an engineering analysis shall be submitted to the building official with the construction documents compliance with the requirements of Chapter 16 for wind loads." 133 pdf_text
2 2. Revise the exception to item 5 of Section 1016.2 by replacing "kitchen" with "kitchen, laundry or open storage ar (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 47; Amend Coun. J. 6-25-21, p. 32180, Art. II, § 18) 100 pdf_text
2 2. The far side of a public way. 43 pdf_text
2 2. Instead of meeting the requirements for Type A units, attached multistory units with separa egress may be designed and constructed in accordance with Section 1107.8.3. 116 pdf_text
2 2. Areas of sport activity shall not be required to comply with this section or with Section 30 107 pdf_text
2 2. The bottom of the clear opening of an operable window is located less than 36 inches (914 the finished floor and more than 20 feet (6096 mm) above the finished grade or other surface b exterior of the building." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 46; Amend Coun. J. 12-14-22, p. 58278, Art. III, § 4) 100 pdf_text
2 2. Revise Section 1006.2 by deleting "or basement." 87 pdf_text
2 2. Periodic special inspection shall be required for nailing, bolting, anchoring and other faste elements of the seismic force-resisting system, including wood shear walls, wood diaphragms, braces, shear panels and hold-downs. Exception: Special inspections are not required for wood shear walls, shear panels and diaphragms, i nailing, bolting, anchoring and other fastening to other elements of the seismic force- resisting system, fastener spacing of the sheathing is more than 4 inches (102 mm) on center. 159 pdf_text
2 2. Revise Section 410.2.2, including its exception, to read: "410.2.2 Technical production areas: galleries, gridirons and catwalks. Beams designed only for the attachment of portable or fixed theater equipment, gridirons, galleries and catwalks shal constructed of noncombustible materials and a fire-resistance rating shall not be required. These areas shall not be c floors, stories, mezzanines or levels in applying this code." 31 pdf_text
2 2. Revise Section 505.2.1 to read: "505.2.1 Area limitation. The aggregate area of a mezzanine or mezzanines within a room shall be not greater than twenty percent of the floor room or space in which they are located. The enclosed portion of a room shall not be included in a determination of t of the room in which the mezzanine is located. In determining the allowable mezzanine area, the area of the mezzani included in the floor area of the room. Exceptions: 40 pdf_text
2 2. Revise Section 308.2.3 to read: "308.2.3 Six to 16 individuals receiving custodial care. A facility housing not fewer than six and not more than 16 individuals receiving custodial care shall be classified as 21 pdf_text
2 2. Revise the first sentence of Section 3105.3 to read: "Awnings and canopies shall be provided with a covering that complies with one of the following:" 203 pdf_text
2 2. Delete Section 3001.2. 198 pdf_text
2 2 hours Rooms with boilers where the largest piece of equipment is over 46 pdf_text
2 2. Revise exception 3 to Section 2609.4 to read: "3. Greenhouses that are occupied for growing or maintaining plants, without public access, shall be exempt limitations of Table 2609.4 provided that they have a minimum fire separation distance of 10 feet (3048 mm) 195 pdf_text
2 2. Revise Section 1808.2 to read: "1808.2 Design for capacity and settlement. Foundations shall be so designed that the allowable bearing capacity of the soil is not exceeded, and that differential minimized. Foundations in areas with expansive soils or fills shall be designed in accordance with the provisions of Analysis shall consider soil layers underlying the designated load-bearing layer." 169 pdf_text
2 2. Delete Section 1609.1.1.1. 149 pdf_text
2 2. Revise item 1 of Section 1015.3 to read: "1. From adjacent walking surfaces, excluding any horizontal surface 12 inches (305 mm) or less in depth measured to the guard." 99 pdf_text
2 2. Delete Section 1804.4. 164 pdf_text
2 2. In buildings three stories or less in height, townhouses are not required to b 114 pdf_text
2 2. Revise Section 1107.4 to read: "1107.4 Accessible route. Not fewer than one accessible route shall connect accessible building or facility entrances with the primary entrance Accessible unit, Type A unit, Type B unit and Type C unit within the building or facility and with those exterior and i and facilities that serve the units. Exceptions: 112 pdf_text
2 2. Revise Section 2510.7 by deleting "approved." 191 pdf_text
2 2. Temporary structures need not be separated from existing buildings where the aggr area of temporary structures does not exceed 5,000 square feet (465 m2) and the tempo will not impede required means of egress for the existing building. 202 pdf_text
2 2. Revise Section 2613.5, exception 2.2 by replacing "5 feet (1524 mm)" with "15 feet (4572 mm)." 195 pdf_text
2 2. Revise Sections 1405.1.1.1.1 and 1405.1.1.1.2 to read: "1405.1.1.1.1 Fire separation 15 feet or less. Where installed on exterior walls having a fire separation distance of 15 feet (4572 mm) or less, combustible exterio coverings shall not exhibit sustained flaming as defined in NFPA 268. 131 pdf_text
2 2. Revise Table 1404.2 by deleting the rows for: asbestos cement board, asbestos shingles, lead-coated copper, and high-yield copper; and replacing "Steel (approved corrosion resistant)" with "Steel (corrosion resistant)." 129 pdf_text
2 2. Revise Section 904.2.2 to read: "904.2.2 Commercial hood and duct systems. Each required commercial kitchen exhaust hood and duct system required by the Chicago Fire Prevention Code or C Mechanical Code to have a Type I hood shall be protected with an automatic fire-extinguishing system installed in a this code." 71 pdf_text
2 2. Business (see Section 304): Group B. 19 pdf_text
2 2. Insert Tables 705.2.1 and 705.2.2 as shown: TABLE 705.2.1 PROJECTIONS FROM WALLS OF ANY TYPE OF CONSTRUCTION a Type of Projection Material Type Fire Separation Distance (fee 53 pdf_text
2 2. Revise Section 1204.2 and its subsections to read: "1204.2 Natural light. Where required, natural light shall be provided in accordance with Section 1204.2.1, 1204.2.2, 1204.2.3 or 1204.2.4. comply with Sections 1204.2.5 and 1204.2.6. 122 pdf_text
2 2. Delete the exceptions to Section 708.3. 58 pdf_text
2 2. Revise Section 1613.2 to read: "1613.2 Seismic ground motion values. Seismic ground motion values shall be determined in accordance with this section. 152 pdf_text
2 2. Revise Section 1604.5, including the exception, to read: "1604.5 Risk category. Each building and structure shall be assigned a risk category in accordance with Table 1604.5. Where a referenced st specifies an occupancy category, the risk category shall not be taken as lower than the occupancy category specified 144 pdf_text
2 2. Delete Section 3007.2 and its subsections. 200 pdf_text
2 2 hours; or 1 hour and provide automatic sprinkler sy In Group E occupancies, laboratories and vocational shops not classified as Group H 46 pdf_text
2 2. Delete item 4 in Section 913.4. 81 pdf_text
2 2. Add a new Section 3106.1.1 to read: "3106.1.1 Marquees over the public way. Marquees installed over the public way shall also comply with Chapter 32 and Chapter 10-28 of the Municipal Code 204 pdf_text
2 2. Revise Section 306.2 to insert, alphabetically: "Recycling plants." 20 pdf_text
2 2. Prior to occupancy and after sufficient completion for the purposes of pressure-diff flow measurements, and detection and control verification. S101.18.8.2 Qualifications. Approved agencies for smoke control testing shall have expertise in fire protection engineering, mech engineering and certification as air balancers. S101.18.8.3 Reports. A complete report of testing shall be prepared by the approved agency. The report shall include identi devices by manufacturer, nameplate data, design values, measured values and identification tag or ma shall be reviewed by the responsible registered design professional and, when satisfied that the design been achieved, the responsible registered design professional shall sign, seal and date the report. S101.18.8.3.1 Report filing. A copy of the final report shall be filed with the fire code official and an identical copy shall b the building. S101.18.9 Identification and documentation. 227 pdf_text
2 2. Add a new Section 1403.3.3 to read: "1403.3.3 Wood shingles and shakes. Wood shingles and shakes shall comply with Section 1507.8.5." 128 pdf_text
2 2. Add a new Section 1105.2 to read: "1105.2 Entrances to rooms or spaces. Within a building or facility, all required doors, doorways and gates on an accessible route which serve accessible ro shall be accessible." 111 pdf_text
2 2. Add a new Section 1203.2 to read: "1203.2 Cooling and dehumidification equipment and systems. Permanent cooling and dehumidification equipment or systems shall be provided in accordance with Sections 1203.2 122 pdf_text
2 2. Delete the exception to Section 414.2. 32 pdf_text
2 2. Where an elevator opens into a lobby enclosed in accordance with Section 3007.6 or 3008. differential is permitted to be measured between the hoistway and the space immediately outsi from the floor to the enclosed lobby. 230 pdf_text
2 2. Exhausts shall be piped to the outside of the building. 214 pdf_text
2 2. In structures assigned to Seismic Design Category D, special inspections ar for structural steel seismic force-resisting systems where design and detailing in with AISC 360 is permitted by ASCE 7, Table 15.4-1. 158 pdf_text
2 2. In Group R-1 occupancies, only windows in Accessible units are required to be accessible. 119 pdf_text
2 2. Outdoor areas associated with Group R-5 occupancies and located not more than 15 feet (4 above grade plane need only have one means of egress and shall not be assigned an occupant l 86 pdf_text
2 2. Party walls dividing a structure on a single zoning lot into separate buildings are permitted to hav openings in accordance with Section 716 where a perpetual recorded easement or recorded contractua such as a condominium declaration, authorizes the owners of portions of the building located on eithe property line to access the other side for purposes of egress and maintaining the building and its syste 57 pdf_text
2 2. Revise the exception to Section 509.1 to read: "Exception: Incidental uses within and serving a single dwelling unit or sleeping unit are not required to comply wit 47 pdf_text
2 2. Buildings of Group R-2 occupancy, other than congregate living facilities, with not more than fou grade plane and containing not more than ten dwelling units where each fire area contains not more t dwelling units and all required vertical exits are interior exit stairways." 69 pdf_text
2 2. Revise Section 1510.2 and its subsections to read: "1510.2 Mechanical penthouses. Mechanical penthouses in compliance with Sections 1510.2.1 through 1510.2.5 shall be considered as a portion of th below the roof deck on which such penthouses are located. Other penthouses shall be considered as an additional stor building. 138 pdf_text
2 2. Revise Section 2607.1 to read: "2607.1 General. Light-transmitting plastics shall not be used as wall panels in exterior walls in occupancies in Groups A-1, A-2, A-3, and I-3. In other groups, light-transmitting plastics shall be permitted to be used as wall panels in exterior walls, pro walls are not required to have a fire-resistance rating and the installation conforms to the requirements of this sectio shall be erected and anchored on a foundation, waterproofed or otherwise protected from moisture absorption and se of mastic or other approved waterproof coating. Light-transmitting plastic wall panels shall comply with Section 260 194 pdf_text
2 2. Complex systems, where approved, where the control is accomplished by compute using approved, plain English commands. S101.16.3 Control action and priorities. The fire-fighter’s control panel actions shall be as follows: 226 pdf_text
2 2. One or more care recipients that are incapable of self-preservation are located at other than exit discharge serving such a facility. In buildings where ambulatory care is provided on levels other than the level of exit discharge, an automatic system shall be installed throughout the entire floor as well as all floors between the level of ambulatory care level of exit discharge, the level of exit discharge, and all floors below the level of exit discharge. 68 pdf_text
2 2. Museums with a gross floor area of 5,000 square feet (465 m2) or more. 111 pdf_text
2 2. Revise Section 2407.1.1 to read: "2407.1.1 Loads. The panels and their support system shall be designed to withstand the loads specified in Section 1607.8. Glass guar shall be designed using a factor of safety of four in combination with the mean modulus of rupture for the type of gla Table 2407.1.1. TABLE 2407.1.1 MODULUS OF RUPTURE 188 pdf_text
2 2. Both the windward and leeward wind loads are transmitted by roof and vertically spanning wall as through continuous floor and roof diaphragms, to the main windforce-resisting system. 149 pdf_text
2 2. The reactions resulting from the dead load and live load specified in Table 1607.1, or the snow loa 146 pdf_text
2 2. Delete Section 405.5 and its subsections. 27 pdf_text
2 2. Vegetative roofs, roof gardens and landscaped roofs. 142 pdf_text
2 2. Revise the first sentence of Section 1708.2.2 to read: "In the absence of applicable load test procedures contained within a material standard referenced by this code or acc criteria for a specific material or method of construction, the existing structure shall be subjected to a test procedure registered design professional that simulates applicable loading and deformation conditions. The test procedure shall by the building official." 162 pdf_text
2 2. Any building or structure or site improvement used or held out for use or intended for use by the p employees for one or more of, but not limited to, the following: the purpose of gathering, recreation, t lodging, education, employment, institutional care, or the purchase, rental, sale or acquisition of any g property or services; places of public display or collection; social service establishments; and stations specified public transportation. 13 pdf_text
2 2. Replace Table 1020.1 as shown: TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING a. For requirements for occupancies in Group I-2, see Sections 407.2 and 407.3. b. For a reduction in the fire-resistance rating for occupancies in Group I-3, see Section 408.8. c. [Reserved.] d. [Reserved.] e. In Groups A-1, A-2, A-3, and A-4 occupancies, corridors serving and visually separated from a room or suite of rooms with an occupant load of 300 have a fire-resistance rating of not less than 1 hour. 101 pdf_text
2 2. Revise Section 422.3.1 by deleting "Sections 403 and 404 of." 34 pdf_text
2 2. The sheathing is wood structural panel or steel sheets on only one side of the shear panel or diaphragm assembly and the fastener spacing of the sheathing is more than 4 i mm) on center. 159 pdf_text
2 2. Add a new Section 304.2 to read: "304.2 Telecommunications equipment areas. A telecommunication equipment area that is associated with an occupancy in the same building is not considered a s occupancy." 19 pdf_text
2 2. Revise Table 2509.2 by adding a row to read: "Fiber-reinforced gypsum panels | ASTM C1278" 191 pdf_text
2 2. Revise the exception to Section 1012.6.4 by replacing "Group R-2 and R-3" with "Group R-2, R-3 and R-5." 98 pdf_text
2 2. Does not connect more than two stories and: 60 pdf_text
2 2. Revise Section 1402.4 by replacing "Exterior walls" with "Exterior walls, including fire-resistant joint systems,". 128 pdf_text
2 2. Add new exceptions following Section 1803.1 to read: "Exceptions: 163 pdf_text
2 2. Operable windows where the openings will not allow a 4-inch-diameter (102 mm) sphere within 3 mm) of the finished floor or a 6-inch-diameter (152 mm) sphere within 42 inches (1067 mm) of the fi pass through the opening when the window is in its largest opened position. 100 pdf_text
2 2. For occupancies in Group R-3 and R-5, and within individual dwelling units in occupancies in Group R-2 open sides of stairs shall have a height not less than 34 inches (864 mm) measured vertically from a line conn leading edges of the treads. 99 pdf_text
2 2. A stairway is designed to accommodate the future installation of a wheelchair lift t with the Chicago Conveyance Device Code. Maneuvering clearances at the top and bot wheelchair lift shall not be required if the width of the corridor, hallway or other space stairway is not less than 36 inches (914 mm). Conduit for future electrical wiring and p operation of a wheelchair lift shall be provided from the power source to a location at t where the connection would be made when the lift is installed. 117 pdf_text
2 2. Revise Section 1809.6 by deleting "in an approved manner." 170 pdf_text
2 2. Add a new exception 4 to Section 1028.1 to read: "4. Up to 100 percent of the number, minimum width, and required capacity of interior exit stairways and exterior e permitted to egress through a lobby or similar common area on the level of exit discharge provided that all of the foll conditions are met: 104 pdf_text
2 2. Revise Section 1504.5 to read: "1504.5 Edge securement for low-sloped roofs. Low-sloped roof built-up, modified bitumen and single-ply roof system metal edge securement, except gutters, shall and installed for wind loads in accordance with Chapter 16 and tested for resistance in accordance with Test Method and RE-3 of ANSI/SPRI ES-1, except basic design wind speed, V, shall be determined from Section 1609.3." 135 pdf_text
2 2. Insert the following standard under ASCE: "41–17: Seismic Evaluation and Retrofit of Existing Buildings" 216 pdf_text
2 2. Van-accessible spaces are not required in a parking facility exclusively serving the residents of a or R-4 occupancy that contains zero Accessible units and no more than 19 dwelling units or sleeping u either Type A units or Type B units." 112 pdf_text
2 2. Revise Section 1406.5 to read: "1406.5 Approval. Results of tests or an engineering analysis shall be submitted to the building official as part of the construction docum demonstrate compliance with the requirements of Chapter 16 for wind loads." 132 pdf_text
2 2. Isolated deep foundation elements supporting posts and bracing from decks and patios app Group R-3, R-4, R-5 and U occupancies not exceeding two stories of light-frame construction permitted to be reinforced as required by rational analysis but with not less than one No. 4 bar, spirals, where the lateral load, E, to the top of the element does not exceed 200 pounds (890 N provides adequate lateral support in accordance with Section 1810.2.1. 174 pdf_text
2 2. Smoke detectors in Group I-3 occupancies. 67 pdf_text
2 2. Revise the first two sentences of Section 1603.1.3 to read: "The ground snow load, Pg, shall be indicated. The following additional information shall also be provided, regardle snow loads govern the design of the roof:" 144 pdf_text
2 2. Add a new Section 3301.3 to read: "3301.3 Delivery and removal. Delivery and removal of equipment and materials from the construction site shall be done in a manner that prevents i damage to persons, adjoining properties and the public way." 207 pdf_text
2 2. Replace Table 1610.1 as follows: TABLE 1610.1 LATERAL SOIL LOAD For SI: 1 pound per square foot per foot of depth = 0.157 kPa/m, 1 foot = 304.8 mm. 151 pdf_text
2 2. A single row of deep foundation elements without lateral bracing is permitted for Group R and light-frame construction not exceeding two stories above grade plane or 35 feet (10 668 height, provided that the centers of the elements are located within the width of the supported 170 pdf_text
2 2. Delete Section 706.2. 57 pdf_text
2 2. Delete Section 1703.2. 155 pdf_text
2 2. Delete Section 1805.1.1. 165 pdf_text
2 2. For mandrel-driven pipes or tubes, the minimum wall thickness shall be 1/10 inch (2.5 mm 173 pdf_text
2 2. More than 10 percent of the soil particles pass a No. 200 sieve (75 µm), determined in accordance D422. 163 pdf_text
2 2. Revise Section 1011.3 by replacing "80 inches (2032 mm)" with "7 feet (2134 mm)." 95 pdf_text
2 2. Where approved by the fire code official, in buildings in occupancy Group A having an occupant less, Groups B, F, M and S, and in places of religious worship, the main door or doors are permitted t with key-operated locking devices from the egress side provided: 94 pdf_text
2 2. The seismic force-resisting system of the structure consists of reinforced masonry or reinf and the building height of the structure does not exceed 25 feet (7620 mm). 158 pdf_text
2 2. Add a new Section 3307.2 to read: "3307.2 Additional requirements. Excavation work on private property shall comply with Section 406 of the Chicago Construction Codes Administrati Provisions." 209 pdf_text
2 2. Revise Section 707.3.5 by replacing "Section 1026.1" with "Section 1026.2." 58 pdf_text
2 2. Revise Section 1705.2 and its exception to read: "1705.2 Steel construction. The special inspections and nondestructive testing of steel construction shall be in accordance with this section. Exception: Special inspections of the steel fabrication process shall not be required where the fabrication pro entire building or structure does not include any welding, thermal cutting or heating operation of any kind. In fabricator shall be required to maintain records so that, at any time during the fabrication process, the materia and grade for the main stress-carrying elements are capable of being determined." 157 pdf_text
2 2. Group I occupancies. 82 pdf_text
2 2. Group U occupancies. 32 pdf_text
2 2. Revise Section 2211.1.2 to read: "2211.1.2 Prescriptive framing. Group R-5 occupancies, less than or equal to three stories above grade plane, shall be permitted to be constructed in with AISI S230 subject to the limitations therein, provided that the building may contain up to three dwelling units." 182 pdf_text
2 2. Revise Section 3005.4 by replacing "fire-protection rating" with "fire-resistance rating." 199 pdf_text
2 2. Revise Section 1106.2 to read: "1106.2 Groups R-2, R-3 and R-4. Accessible parking spaces shall be provided in Group R-2, R-3 and R-4 occupancies in accordance with Items 1 thro applicable. 111 pdf_text
2 2. Trailers used in connection with duly authorized construction. 219 pdf_text
2 2. Revise Section 406.2.4 by replacing "sloped" with "sloped at least one-quarter inch per foot (6.35 mm per 305 m 28 pdf_text
2 2. Revise Section 1905.1.7 by replacing "Seismic Design Category C, D, E or F" with "Seismic Design Category C and two-family" with "one-, two- and three-family" and "Seismic Design Category D or E" with "Seismic Design Cat 177 pdf_text
2 2. Housing at a place of education that is leased on a year-round basis exclusively to students or faculty and that does not contain any public use areas or common use areas 114 pdf_text
2 2. Buildings of Group R-3, R-4 or R-5 occupancy using the provisions of AWC WFCM (incl buildings containing up to 3 dwelling units). 148 pdf_text
2 2. Fire alarm systems. 27 pdf_text
2 2. Accessible parking spaces shall be permitted to be located in different parking facilities if substant equivalent or greater access and usability to people with disabilities is provided in terms of distance fr accessible entrance or entrances, parking fee and user convenience." 112 pdf_text
2 2. Screw attachment, bolting, anchoring and other fastening of elements of the seismic force- system, including shear walls, braces, diaphragms, collectors (drag struts) and hold- downs. Exception: Special inspections are not required for cold-formed steel light-frame shear walls and dia including screw installation, bolting, anchoring and other fastening to components of the seismic forc system, where either of the following applies: 159 pdf_text
2 2. Wood handrails shall be permitted for all types of construction." 97 pdf_text
2 (cont. 2) ttings shall be wrought copper or brass, solder type in accorda ASME B16.18 or ASME B16.22. Changes in direction shall be made with appropriate tool bends. Brass com fittings shall be used at final connection to devices; other joints shall be brazed using a BCuP-5 brazing alloy above 1,100°F (593°C) and liquids below 1,500°F (816°C). Brazing flux shall be used on copper-to-brass joi Exception: Nonmetallic tubing used within control panels and at the final connection to devices provi the following conditions are met: 225 pdf_text
2.1 2.1. Delete exception 2 to Section 1005.3.1. 87 pdf_text
2.1 2.1. Revise Section 1020.1.1 by replacing "Section 3006.2.1" with "Section 3002.1.1." 101 pdf_text
2.1 2.1 Revise the exceptions to Section 1810.2.2 to read: "Exceptions: 170 pdf_text
2.1 2.1. The locking device is readily distinguishable as locked. 94 pdf_text
2.1 2.1. Is located in a building of Type IA, IB, or IIA construction. 60 pdf_text
2.1 2.1. In Group R-3 and R-5 occupancies. 95 pdf_text
2.1 2.1. Revise Section 2308.2.3 by deleting item 3. 185 pdf_text
2.1 2.1. The footings support walls of light-frame construction. 157 pdf_text
2.2 2.2. One of the stories is a level of exit discharge. 60 pdf_text
2.2 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stati DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED. The sign shall be i (25 mm) high on a contrasting background. 94 pdf_text
2.2 2.2. The footings are designed in accordance with Table 1809.7. 157 pdf_text
2.2 2.2. Within dwelling units in Group R-2 occupancies. 95 pdf_text
2.3 2.3. In Group U occupancies that are accessory to a Group R-3 occupancy or accessory to individual in Group R-2 occupancies." 95 pdf_text
2.3 2.3. Where the building contains a Group R occupancy, the building is equipped throughout automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 24; Amend Coun. J. 6-25-21, p. 32180, Art. II, § 11) 60 pdf_text
2.3 2.3. The use of the key-operated locking device is revocable by the fire code official for due 94 pdf_text
2.3 2.3. The structural design of the footing is based on a specified compressive strength, f 'c, not more t pounds per square inch (psi) (17.2 MPa), regardless of the compressive strength specified in the perm construction documents or used in the footing construction." 158 pdf_text
20 20. Revise item 5 in Section 1010.1.9.7 to read: "5. The procedures for unlocking the doors shall be described and accepted as part of the emergency plannin preparedness required by the Chicago Fire Prevention Code." 94 pdf_text
20 20. Add a new Section 406.9 to read: "406.9 Parking facilities. Parking facilities shall comply with the provisions of Sections 406.2, 406.4 and 406.5 or 406.6, as modified by Secti 30 pdf_text
20 20,0 SM UL UL 41 pdf_text
20 20. Revise Section 1507.18.2 to read: "1507.18.2 Deck slope. BIPV roof panels shall not be used on low-sloped roofs." 137 pdf_text
20 20. Revise Section 2308.6.7.2 by deleting "approved." 186 pdf_text
20 20. Add a new Section 403.4.8.5 to read: "403.4.8.5 Diesel generator. In high-rise buildings that are more than 400 feet (122 m) in building height, a diesel-driven generator with an on-pr supply sufficient for not less than 4 hours of full-demand operation shall be provided to supply standby and emergen loads. The fuel source for generators in high-rise buildings that are 400 feet (122 m) or less in building height shall be eithe natural gas." 26 pdf_text
20 20. Revise Section 907.2.9.1 to read: "907.2.9.1 Manual fire alarm system. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be Group R-2 occupancies where the building contains more than 16 dwelling units or sleeping units." 75 pdf_text
20 20. Revise Section 1404.12.5 to read: "1404.12.5 Joints. Unless otherwise specifically approved by the building official, abutting edges of thin exterior structural glass veneer ground square. Horizontal joints shall be held to not less than 0.063 inch (1.6 mm) by a nonrigid substance or device. exterior structural glass veneer abuts nonresilient material at sides or top, expansion joints not less than 1/4 inch (6.4 shall be provided." 130 pdf_text
20 20. Revise exception 2o to Section 1705.13.1.1 by replacing "D, E or F" with "D." 160 pdf_text
20 20. Revise note c to Table 2603.13.2 by replacing "approved" with "engineered." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 88) 193 pdf_text
20 20. Revise the title of Section 1107.7.2 to "Multistory Type B units." 115 pdf_text
20 20. Revise the definition of "atrium" to read: "ATRIUM. A vertical space that is closed at the top connecting two or more stories in a Group I-2 or I-3 occupancy more stories in any other occupancy. " 4 pdf_text
20 20. Revise Section 1810.3.3.1.7 to read: "1810.3.3.1.7 Load-bearing capacity. Ultimate load capacities shall be determined in accordance with Section 1810.3.3.1.7.1, 1810.3.3.1.7.2 or 1810.3.3.1. 173 pdf_text
20 20 to less than 25 g Unprotected, Nonsprinklered (UP, NS) 55 pdf_text
20 20. Revise Section 903.2.8.1 to read: "903.2.8.1 Group R-3 and R-5. An automatic sprinkler system installed in accordance with Section 903.3.1.3 shall be permitted in Group R-3 and R occupancies." 69 pdf_text
20 20,0 SM UL 42 pdf_text
20 20. Revise exception 1 to Section 1607.8.1 to read: "1. For Group R-5 occupancies and within individual dwelling units, only the single concentrated load requi 148 pdf_text
20.1 20.1. Revise Section 1010.1.9.8 by inserting an item 3 to read: “3. Group A occupancies in airport terminals.” 94 pdf_text
20.1 20.1. Revise items 4 and 5 in Section 903.2.9 to read: "4. A Group S-1 fire area used for the storage of commercial motor vehicles where the fire area exceeds 5,0 (464 m 2 ). 69 pdf_text
20.2 20.2. In Section 903.2.10.1, reset the following term in italic type: "commercial motor vehicle." 69 pdf_text
200 200 square feet (18.6 m2), whichever is greater, are permitted to be classified as dwelling units with accessory occup accordance with Section 508.2." 33 pdf_text
200 200. Revise the definition of "roof replacement" to read: "ROOF REPLACEMENT. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 14 pdf_text
201 201. Insert the following definition: "ROOFTOP, OCCUPIABLE. See "Occupiable rooftop." 14 pdf_text
201.1 201.1 Definitions. The definitions in Section 202 shall apply to italicized words throughout this code, except where specifically limited chapter or section. Unless the context requires otherwise, the definitions in Section 202 shall also apply to non-italici throughout this code. 3 pdf_text
201.2 201.2 Interchangeability. Words used in the present tense include the future; words stated in the masculine gender include the feminine and ne singular number includes the plural and the plural includes the singular. 3 pdf_text
201.3 201.3 Words defined in other codes. Where non-italicized words are not defined in this code and are defined in the Chicago Construction Codes Administ Provisions, Chicago Conveyance Device Code, Chicago Electrical Code, Chicago Fire Prevention Code, Chicago F Chicago Mechanical Code, Chicago Energy Conservation Code, Chicago Plumbing Code, Chicago Building Rehabi or Chicago Minimum Requirements for Existing Buildings, such words shall have the meanings ascribed to them in t 3 pdf_text
201.4 201.4 Words not defined. Where italicized words are not defined in Section 202 or non-italicized words are not defined in Section 202 or any o referenced in Section 201.3, such words shall have the meaning given in the latest edition of Merriam Webster’s Col Dictionary as the context implies." 3 pdf_text
202 202. Insert the following definition: "SCAFFOLDING. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions." 14 pdf_text
203 203. Delete the definition of "self-luminous." 14 pdf_text
203.1 203.1 Scope. Grade plane, building height, building area and floor area shall be established in accordance with Sections 203.2 thr respectively. 17 pdf_text
203.2 203.2 Grade plane. With respect to each building, grade plane shall be a reference plane representing the average finished ground level a building at exterior walls. Where the finished ground level slopes away from the exterior walls, the reference plane established by the lowest points within the area between the building and the property line or, where the property lin 17 pdf_text
203.3 203.3 Building height. Building height shall be the vertical distance from grade plane to the mean elevation of the highest roof plane. For p code, building height is not the same as mean roof height. Exceptions: 17 pdf_text
203.4 203.4 Building area. Building area shall be the sum of the horizontal area included within surrounding exterior walls, or exterior walls an exclusive of courts for each story above grade plane and the horizontal area of mezzanines, equipment platforms and the building not provided with surrounding walls, such as patios and exterior balconies, shall be included in the build such areas are included within the horizontal projection of the roof, floor or walking surface above. The floor area of shall be included in building area where required by Section 506.1.3. Exception: The horizontal area of the portion of any story, mezzanine or loft with a ceiling height of less tha mm) shall be excluded from the calculation of building area. 17 pdf_text
203.5 203.5 Floor area. Each reference to "floor area" in this code shall mean gross floor area unless the provision specifically references ne 18 pdf_text
203.5.1 203.5.1 Gross floor area. Gross floor area shall be measured in the manner provided for determining building area in Section 203.4 wi deduction for the horizontal area of shafts without openings and the thickness of interior walls enclosing such shall be no deduction for corridors, stairways, ramps, closets, mechanical rooms, elevator shafts, toilet rooms of interior walls, columns, or other features. 18 pdf_text
203.5.1.1 203.5.1.1 Separated mixed occupancies. The gross floor area of a mixed occupancy separated in accordance with Section 508.4 shall be the ho included within surrounding exterior walls, fire walls and fire barriers. Areas of the occupancy not pr surrounding walls, such as patios and exterior balconies, shall be included in the gross floor area if su included within the horizontal projection of the roof, floor or walking surface above. 18 pdf_text
203.5.1.2 203.5.1.2 Unseparated mixed occupancies. The gross floor area of an occupancy that is not separated in accordance with Section 508.4 shall be centerline of interior walls and partitions that separate the occupancy from other occupancies in the sa 18 pdf_text
203.5.2 203.5.2 Net floor area. Net floor area shall be the actual occupiable horizontal area, not including columns, permanently attached eq furnishings that are 28 inches (711 mm) or greater above the floor, the thickness of interior walls and unoccu areas such as aisles, corridors, stairways, ramps, individual wellness/lactation rooms, toilet rooms, mechanic closets." (Amend Coun. J. 7-24-19, p. 3646, § 25; Amend Coun. J. 2-19-20, p. 14473, Art. II, § 2; Amend Coun. J. 6-25-21, p. 32180, Amend Coun. J. 1-26-22, p. 43756, Art. II, § 2) CHAPTER 14B-3 OCCUPANCY CLASSIFICATION AND USE 18 pdf_text
204 204. Revise the definition of "service entrance" to read: "SERVICE ENTRANCE. An entrance intended primarily for delivery of goods or services." 14 pdf_text
205 205. Revise the definition of "site" to read: "SITE. A lot or a designated portion of a public way." 15 pdf_text
206 206. Revise the definition of "sleeping unit" to read: "SLEEPING UNIT. A single unit that provides rooms or spaces for one or more persons, includes permanent provis sleeping and can include provisions for living, eating and either sanitation or kitchen facilities but not both. Such roo that are part of a dwelling unit occupied by a single household are not sleeping units." 15 pdf_text
207 207. Delete the definition of "soft contained play equipment structure." 15 pdf_text
208 208. Revise the definition of "solid" to read: "SOLID. As defined in Chapter 2 of the Chicago Fire Prevention Code." 15 pdf_text
209 209. Insert the following definition: "SPACE (for Chapter 11). A definable area, such as a room, toilet room, hall, assembly area, entrance, storage roo courtyard or lobby." 15 pdf_text
21 21. Revise Section 1404.12.6 by replacing "sidewalk" with "ground." 130 pdf_text
21 21. Revise the definition of "attic" to read: "ATTIC. The unfinished space between the ceiling framing of the highest story that contains occupiable space and t of the roof structure. An attic with a clear height of 81 inches (2057 mm) or more between the top of the ceiling fra underside of the roof structure shall be considered an additional story." 4 pdf_text
21 21. Revise Section 1507.18.4.2, excluding the exception, to read: "1507.18.4.2 Ice barrier. An ice barrier consisting of not fewer than two layers of underlayment cemented together or of a self-adhering poly bitumen sheet shall be used instead of normal underlayment and extend from the lowest edges of all roof surfaces to than 24 inches (610 mm) inside the exterior wall line of the building." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 69) 137 pdf_text
21 21. Revise exception 2 to Section 907.2.9.1 to read: "2. Manual fire alarm boxes are not required where the building is equipped throughout with an automatic s system installed in accordance with Section 903.3.1.1 or 903.3.1.2 and the occupant notification appliances w accordance with Section 907.5 upon a sprinkler water flow." 75 pdf_text
21 21. Add a new Section 403.4.9 to read: "403.4.9 Electrical equipment rooms. Electrical equipment rooms in high-rise buildings shall comply with Sections 403.4.9.1 through 403.9.3. 26 pdf_text
21 21. Revise Section 1607.9 to replace "an approved method" with "an accepted engineering practice." 148 pdf_text
21 21. Revise Section 1810.3.3.2 by replacing "an approved method of analysis" with "accepted engineering analysis." 173 pdf_text
21 21. Revise Section 2308.6.8.1 by deleting all text after the first exception, including the subsequent exceptions. 186 pdf_text
21 21. Revise Section 903.2.10 to read: "903.2.10 Group S-2 parking garages. An automatic sprinkler system shall be provided throughout buildings containing parking garages in accordance wit where any of the following conditions exists: 69 pdf_text
21 21. Delete Section 1107.7.5. 115 pdf_text
21 21. Revise Section 1705.13.1.2 by replacing "Seismic Design Category B, C, D, E or F" with "Seismic Design Cate 160 pdf_text
21 21. Revise items 3 and 4 (including the exception) in Section 1010.1.9.8.1 to read: "3. The delayed egress locking system shall have the capability of being deactivated at the fire command pa this section shall prohibit installation of deactivation means at additional locations. 94 pdf_text
21.1 21.1. Revise Section 1607.10.4 to read: "1607.10.4 Fall arrest, lifeline, and rope descent system anchorages. In addition to any other applicable live loads, fall arrest, lifeline, and rope descent system anchorages and structural e support these anchorages shall be designed for a live load of not less than 3,100 pounds (13.8 kN) for each attached l direction that the load can be applied. Anchorages of horizontal lifelines and the structural elements that support thes shall be designed for the maximum tension that develops in the horizontal lifeline from these live loads." 148 pdf_text
210 210. Delete the definition of "special flood hazard area." 15 pdf_text
211 211. Revise the definition of "special inspection" to read: "SPECIAL INSPECTION. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions. 15 pdf_text
2113.11.1.5 2113.11.1.5 for marking)." 180 pdf_text
212 212. Revise the definition of "special inspector" to read: "SPECIAL INSPECTOR. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions." 15 pdf_text
213 213. Revise the definition of "specified compressive strength of masonry" to read: "SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, f'm. Minimum compressive strength, expressed as of net cross-sectional area, required of the masonry used in construction by the permitted construction documents, an the project design is based. Whenever the quantity f'm is under the radical sign, the square root of numerical value o and the result has units of pounds per square inch (psi) (MPa)." 15 pdf_text
214 214. Revise the definition of "spray room" to read: "SPRAY ROOM. As defined in Chapter 2 of the Chicago Fire Prevention Code." 15 pdf_text
215 215. Revise the definition of "stage" to read: "STAGE. A space utilized for entertainment or presentations, which includes overhead hanging curtains, drops, scen theatrical effects other than lighting and sound." 15 pdf_text
216 216. Revise the definition of "start of construction" to read: "START OF CONSTRUCTION. As defined in Chapter 2 of the Chicago Construction Codes Administrative Prov 15 pdf_text
217 217. Delete the definition of "storm shelter" (and related definitions). 15 pdf_text
218 218. Revise the definition of "story" to read: "STORY. That portion of a building included between the upper surface of a floor and the upper surface of the floor above (see "Attic," "Basement," "Building height," "Grade plane," "Loft" and "Mezzanine"). For purposes of Chapters 16 and 23, a story is measured as the vertical distance from top to top of two successive tie finished floor surfaces and, for the topmost story, from the top of the floor finish to the top of the ceiling joists or, w not a ceiling, to the top of the roof rafters." 15 pdf_text
219 219. Revise the definition of "story above grade plane" to read: "STORY ABOVE GRADE PLANE. Any story having its finished floor surface entirely above grade plane, or in finished surface of the floor next above is: 15 pdf_text
22 22. Delete Section 2308.6.8.2. 186 pdf_text
22 22. Revise Section 1607.13 to delete "and marquees." 148 pdf_text
22 22. Revise the exception to Section 1810.3.5.2.2 to read: "Exception: The length of the element is permitted to exceed 30 times the specified diameter, provided that the desi installation of the deep foundations are under the direct supervision of a registered geotechnical engineer knowledge field of soil mechanics and deep foundations or their qualified representative. The registered geotechnical engineer s report to the owner stating that the elements were installed in compliance with the permitted construction documents. 173 pdf_text
22 22. Add a new exception to Section 403.5.1 to read: "Exception: In Group R-2 occupancies with an automatic smoke detection system that activates the occupant notific accordance with Section 907.5 installed throughout all interior corridors serving dwelling units, required interior exit shall be separated by a distance not less than 15 feet (4572 mm)." 26 pdf_text
22 22. Revise the title of Section 903.2.10.1 to "Commercial-vehicle parking garages." 69 pdf_text
22 22. Delete item 6.2 in Section 1010.1.9.8.1. 94 pdf_text
22 22. Revise the definition of "baled cotton" to read: 4 pdf_text
22 22. Revise Section 1404.13.1 to read: "1404.13.1 Installation. Windows and doors shall be installed in accordance with manufacturer’s written instructions or an engineering analy size and spacing shall be provided in such instructions and shall be calculated based on maximum loads and spacing or analysis." 130 pdf_text
22 22. Revise exception 1 to Section 1705.13.1.2 by replacing "B or C" with "C." 160 pdf_text
22 22. Insert new Sections 1107.7.6 and 1107.7.7 to read: "1107.7.6 Multistory Type A units. A multistory unit is not required to be a Type A unit if the required number of Type A units is met by other types of u throughout the building. 115 pdf_text
22 22. Revise exception 3 to Section 907.2.9.1 by deleting "approved." 75 pdf_text
22.1 22.1. Revise Section 907.2.9.2 by replacing "smoke alarms" with "smoke alarms, heat alarms and heat detectors" in heading and body. 75 pdf_text
22.1 22.1. In Section 903.2.10.1, reset the following term in italic type: "commercial motor vehicle." 69 pdf_text
22.2 22.2. Revise Section 903.2.11 by replacing "903.2.11.6" with "903.2.11.8." 69 pdf_text
220 220. Revise the definition of "structural observation" to read: "STRUCTURAL OBSERVATION. The visual observation of the structural system by a registered design professi general conformance to the permitted construction documents." 15 pdf_text
221 221. Revise the definition of "substantial damage" to read: "SUBSTANTIAL DAMAGE. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 15 pdf_text
2212.1 2212.1 General. The structural use of cast iron elements in buildings, structures and portions thereof shall be in accordance with AST 182 pdf_text
2212.2 2212.2 Minimum thickness. The minimum thickness of cast iron shall be not less than the following: 182 pdf_text
2212.3 2212.3 Limitations. Cast iron columns shall not be used where subject to eccentric loads that produce a net tension in the material, nor in structural frame which is required to resist stress due to wind. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 82) CHAPTER 14B-23 WOOD 182 pdf_text
222 222. Revise the definition of "substantial improvement" to read: 15 pdf_text
223 223. Insert the following definition: "TELECOMMUNICATIONS EQUIPMENT AREA. An area or enclosed room within a building where electroni used for the transmission of audio, video and data, power equipment (e.g., dc converters, inverters and batteries), tec equipment (e.g., computers) and conductors dedicated solely to the operation of the equipment are located, including served by the same ventilation system." 16 pdf_text
223.1 223.1. Insert the following definition: "TELEPHONE EXCHANGE. A building or portion of a building that primarily houses communications switching and that is owned or operated by a person whose primary business is the providing of communication services other t television." 16 pdf_text
224 224. Insert the following definition: "TEMPORARY. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions." 16 pdf_text
225 225. Insert the following definition: "TEMPORARY (for Chapter 11). A building or element of a building which is not permanent and is designed to b a short period of time for some special purpose. Temporary buildings or facilities include, but are not limited to, revi temporary classrooms, bleacher areas, stages, platforms and daises, fixed furniture systems, wall systems, exhibit are banking facilities and temporary health screening facilities." 16 pdf_text
226 226. Insert the following definition: "TEMPORARY OVERNIGHT SHELTER. A building, or portion thereof, in which sleeping accommodations are no more than 12 hours per day, for three or more individuals who are not related to the owner, operator, manager or occupants by blood or by marriage, without provisions for medical care." 16 pdf_text
227 227. Revise the definition of "tires, bulk storage of" to read: "TIRES, BULK STORAGE OF. As defined in Chapter 2 of the Chicago Fire Prevention Code." 16 pdf_text
228 228. Revise the definition of "townhouse" to read: "TOWNHOUSE. A dwelling unit constructed in a group of four or more attached dwelling units in which each dwel extends from the foundation or a horizontal assembly with a fire-resistance rating of not less than 4 hours to the roof public way, yard or outer court on at least two sides." 16 pdf_text
229 229. Revise the definition of "toxic" to read: "TOXIC. As defined in Chapter 2 of the Chicago Fire Prevention Code." 16 pdf_text
23 23. Revise Section 2308.6.8.3 by replacing "Seismic Design Categories B, C, D and E" with "Seismic Design Categ C." 186 pdf_text
23 23. Revise exception 2 to Section 1705.13.1.2 by replacing "D, E or F" with "D." 160 pdf_text
23 23. Delete the second sentence of Section 1810.3.5.2.3. 173 pdf_text
23 23. Revise Section 1404.14 and its subsections to read: "1404.14 Vinyl siding. Vinyl siding conforming to the requirements of this section and complying with ASTM D3679 shall be permitted on of buildings where the building height is less than or equal to 45 feet (13 716 mm). Vinyl siding shall be secured to t 130 pdf_text
23 23. Revise Section 1607.13.2 to delete "and marquees." 148 pdf_text
23 23. Delete Section 403.5.2. 26 pdf_text
23 23. Add new item 9 in Section 1010.1.9.8.1 to read: "9. The door must swing in the direction of egress travel." 95 pdf_text
23 23. Add a new Section 1107.8 to read: "1107.8 Residential planned developments. Dwelling units and sleeping units in a planned development shall be accessible in accordance with Sections 1107.8.1 115 pdf_text
23 23. Delete Section 907.2.9.3. 75 pdf_text
23 23. Revise Section 903.2.11.1.2 by deleting "approved." 69 pdf_text
23 23. Revise the definition of "baled cotton, densely packed" to read: "BALED COTTON, DENSELY PACKED. As defined in Chapter 2 of the Chicago Fire Prevention Code." 5 pdf_text
230 230. Delete the definition of "tsunami design geodatabase." 16 pdf_text
2303.1.1.1 2303.1.1.1 Certificate of inspection. In lieu of a grade mark on the material, a certificate of inspection as to species and grade issued by a lumber inspection agency meeting the requirements of this section shall be accepted for precut, remanufactured or ro lumber and for sizes larger than 3 inches (76 mm) nominal thickness. 183 pdf_text
2303.1.1.2 2303.1.1.2 End-jointed lumber. Where approved for use, end-jointed lumber may be used interchangeably with solid-sawn members of the sa and grade. End-jointed lumber used in an assembly required to have a fire-resistance rating shall have the de "Heat Resistant Adhesive" or "HRA" included in its grade mark." 183 pdf_text
231 231. Delete the definition of "tsunami design zone." 16 pdf_text
232 232. Insert the following definition: "TYPE C UNIT. A dwelling unit designed and constructed for limited accessibility in accordance with this code an provisions for Type C units (visitable units) in ICC A117.1." 16 pdf_text
233 233. Revise the definition of "unstable (reactive) material" to read: "UNSTABLE (REACTIVE) MATERIAL. As defined in Chapter 2 of the Chicago Fire Prevention Code." 16 pdf_text
234 234. Revise the definition of "use (material)" to read: "USE (MATERIAL). As defined in Chapter 2 of the Chicago Fire Prevention Code." 16 pdf_text
235 235. Insert the following definition: "VEHICULAR WAY (for Chapter 11). A route provided for vehicular traffic, such as a street, driveway or parkin 16 pdf_text
236 236. Revise the definition of "water-reactive material" to read: "WATER-REACTIVE MATERIAL. As defined in Chapter 2 of the Chicago Fire Prevention Code." 16 pdf_text
237 237. Delete the definition of "windborne debris region." 16 pdf_text
238 238. Insert the following definition: "WORK-AREA EQUIPMENT. Any machine, instrument, engine, motor, pump, conveyor or other apparatus used work. This term shall only apply to equipment that is permanently installed or built-in in employee work areas. Work equipment does not include passenger elevators and other accessible means of vertical transportation." 16 pdf_text
239 239. Revise the definition of "yard" to read: 16 pdf_text
24 24,0 SM UL UL 41 pdf_text
24 24,000 N I-1 NS d, e UL 42 pdf_text
24 24. Revise Section 903.2.11.1.3 by deleting "approved." 69 pdf_text
24 24. Add a new item 4 to Section 907.2.10.1 to read: "4. At the uppermost ceiling of each interior exit stairway." 75 pdf_text
24 24. Revise Section 1705.13.2 to read: "1705.13.2 Nonstructural components. For structures assigned to Seismic Design Category C or D, where the requirements of Section 13.2.1 of ASCE 7 for components, supports or attachments are met by seismic qualification as specified in Item 2 therein, the registered de professional shall specify on the permitted construction documents the requirements for seismic qualification by anal experience data. Certificates of compliance for the seismic qualification shall be made available to the building offici in Section 1704.5." 160 pdf_text
24 24. Revise the second sentence of Section 403.5.3 to read: "Stairway doors that are locked from the stairway side shall be capable of being unlocked simultaneously, without u upon a signal from the fire command center and automatically, either by smoke detectors or sprinkler waterflow devi 26 pdf_text
24 24. Delete Section 2308.6.10.2. 186 pdf_text
24 24. Insert a new Section 1107.9 to read: "1107.9 Affordable units. Affordable units shall be accessible in accordance with Sections 1107.9.1 through 1107.9.4. 117 pdf_text
24 24. Delete the definition of "base flood." 5 pdf_text
24 24. Revise Section 1607.13.3 to read: "1607.13.3 Occupiable rooftops. Occupiable rooftops and vegetative roofs are permitted to have their uniformly distributed live loads reduced in acco 148 pdf_text
24 24. Revise Section 1404.16 to read: "1404.16 Fiber-cement siding. Fiber-cement siding complying with Section 1403.10 shall be allowed on exterior walls of Type I, II, III, IV and V c wind pressure resistance or wind speed exposures as indicated by the manufacturer’s listing and label and installatio Where specified, the siding shall be installed over sheathing or materials listed in Section 2304.6 and shall be installe to the water-resistive barrier requirements in Section 1402. Siding and accessories shall be installed in accordance w manufacturer’s instructions. Unless otherwise specified in the manufacturer’s instructions, nails used to fasten the sid studs shall be corrosion- resistant round head smooth shank and shall be long enough to penetrate the studs not less t mm). For cold-formed steel light-frame construction, corrosion-resistant fasteners shall be used. Screw fasteners shal cold-formed steel framing not fewer than three exposed full threads. Other fasteners shall be installed in accordance permitted construction documents and manufacturer’s instructions." 131 pdf_text
24 24. Revise Section 1810.3.5.3.4 to read: "1810.3.5.3.4 Steel pipes and tubes. Steel pipes and tubes used as deep foundation elements shall have a nominal outside diameter of not less than 7 inch Where steel pipes or tubes are driven open ended, they shall have not less than 0.34 square inch (219 mm2) of steel i to resist each 1,000 foot-pounds (1356 Nm) of pile hammer energy, or shall have the equivalent strength for steels ha strength greater than 35,000 psi (241 MPa) or the wave equation analysis shall be permitted to be used to assess com stresses induced by driving to evaluate if the pile section is appropriate for the selected hammer. Where a pipe or tub thickness less than 0.179 inch (4.6 mm) is driven open ended, a suitable cutting shoe shall be provided. Concrete-fill or tubes in structures assigned to Seismic Design Category C or D shall have a wall thickness of not less than 3/16 in The pipe or tube casing for socketed drilled shafts shall have a nominal outside diameter of not less than 18 inches (4 wall thickness of not less than 3/8 inch (9.5 mm) and a suitable steel driving shoe welded to the bottom; the diameter socket shall be approximately equal to the inside diameter of the casing. Exceptions: 173 pdf_text
24 24. Revise Section 1010.1.9.11 by replacing "an approved" with "a." Revise exceptions 3 through 5 to Section 1010.1.9.12 to read: "3. In interior exit stairways serving more than 4 stories, exit doors are permitted to be locked from the side egress side, provided that they are openable from the egress side and capable of being unlocked simultaneous unlatching both automatically, by smoke detectors or waterflow devices, and manually, upon a signal from th command panel, if present, or a signal by building management or emergency personnel from a single locatio main entrance to the building. A telephone or other two-way communication system connected to a constantl location shall be provided in the exit stairway at not less than every fifth story. 95 pdf_text
24.1 24.1. Revise the subtitle of Table 2308.7.1 (2) by deleting "limited." 186 pdf_text
24.2 24.2. Revise the subtitle of Table 2308.7.2(3) by deleting "Ground snow load = 30 psf,". 186 pdf_text
24.3 24.3. Delete Table 2308.7.2(4). 186 pdf_text
24.4 24.4. Revise the subtitle of Table 2308.7.2(5) by deleting "Ground snow load = 30 psf,". 186 pdf_text
24.5 24.5. Delete Table 2308.7.2(6). 186 pdf_text
24.6 24.6. Revise Table 2308.7.3.1 by deleting the columns for no snow load, deleting the columns for ground snow loa deleting the heading rows for "GROUND SNOW LOAD (pounds per square foot)" and "30 pounds per square foot," note g. 186 pdf_text
240 240. Insert the following definition: "ZONING LOT. See "Lot." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 1; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 1; Amend Coun. J. 6-25-21, p. § 1; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 1; Amend Coun. J. 7-20-22, p. 50878, § 1) 17 pdf_text
2435 2435 North L Portla ANSI/CRRC S100–2020: Standard Test Methods for Determining Radiative Properties of Materials" 217 pdf_text
25 25. Revise the title of Table 2308.7.5 by deleting "approved." 186 pdf_text
25 25. Revise Section 903.2.11.3 to read: "903.2.11.3 Buildings more than 70 feet in height. An automatic sprinkler system shall be installed throughout buildings that are more than 70 feet (21.3 m) in building Exception: Parking facilities, in accordance with Section 906.9." 69 pdf_text
25 25. Revise Sections 1404.16.1 and 1404.16.2 by deleting "approved." 131 pdf_text
25 25. Revise the exception to Section 1010.2 to read: "Exception: Horizontal sliding or swinging gates exceeding the 4-foot (1219 mm) maximum leaf width limitation ar exterior fences and walls." 95 pdf_text
25 25. Delete the definition of "base flood elevation." 5 pdf_text
25 25. Revise Section 1810.3.5.3.5 to read: "1810.3.5.3.5 Helical piles. Dimensions of the central shaft and the number, size and thickness of helical bearing plates shall be sufficient to sup loads. The minimum pipe shaft shall have a diameter of not less than 3.5 inches (89 mm) and wall thickness not less (6.4 mm)." 173 pdf_text
25 25. Revise Section 403.5.3.1 to read: "403.5.3.1 Stairway communication system. A two-way communication system shall be provided in accordance with Section 907.2.12.2.1." 26 pdf_text
25 25. Delete Section 1607.15.2. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 73; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 28; Amend Coun. J. 1-26-22, II, § 17; Amend Coun. J. 1-24-24, p. 8634, Art. IV, § 5) 148 pdf_text
25 25% Unprotected, Sprinklered (UP, S) i 55 pdf_text
25 25. Revise Section 1705.13.3 to read: "1705.13.3 Designated seismic systems. For structures assigned to Seismic Design Category C or D and with designated seismic systems that are subject to th of Section 13.2.2 of ASCE 7 for certification, the registered design professional shall specify on the permitted constr documents the requirements to be met by analysis, testing or experience data as specified therein. Certificates of com documenting that the requirements are met shall be made available to the building official as specified in Section 170 160 pdf_text
25 25 to less than 30 g Unprotected, Nonsprinklered (UP, NS) 55 pdf_text
25 25. Revise Section 907.2.10 by inserting the following at the end: " Listed heat detectors complying with UL 521 or complying with UL 539 shall be installed in accordance with Sections 907.2.10. and 907.2.10.8 and NFPA 72." 75 pdf_text
25.1 25.1. Revise Section 907.2.10.2 to read: "907.2.10.2 Groups R-2, R-3, R-4, R-5 and I-1. Single- or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4, R-5 and I-1 rega occupant load at all of the following locations: 75 pdf_text
25.2 25.2. Revise Section 907.2.10.6 to read: "907.2.10.6 Power source. In new construction, required smoke alarms, heat alarms and heat detectors shall receive their primary power from th wiring where such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke al integral strobes that are not equipped with battery backup shall be connected to an emergency electrical system in ac 75 pdf_text
25.3 25.3. Insert a new Section 907.2.10.8 to read: "907.2.10.8 Heat alarms and heat detectors. A heat detector or heat alarm shall be installed in a private garage that is attached to or directly below a dwelling unit unit and shall comply with the following: 75 pdf_text
26 26. Revise Section 1404.17 by deleting "approved." 131 pdf_text
26 26. Delete Section 403.5.4. 26 pdf_text
26 26. Revise Table 2308.7.5 by: a. Revising the first column in the upper portion of the table to read: "RISK CATEGORY I or II III" b. Deleting the rows for V asd = 100 and 110. c. Revising note h by deleting "approved." d. Deleting note g. 186 pdf_text
26 26. Renumber existing Section and Table 903.2.11.6 to 903.2.11.8 and delete the following rows in the table: cover 69 pdf_text
26 26. Insert a new Section 1010.2.2 to read: "1010.2.2 Residential buildings. Exterior gates which are part of the exit discharge for a Group R-2, R-3, R-4 or R-5 occupancy shall conform to the requirements of this section. 95 pdf_text
26 26. Delete the definition of "basement (for flood loads)." 5 pdf_text
26 26. Revise Section 1705.13.4 by replacing "Seismic Design Category B, C, D, E or F" with "Seismic Design Categ 160 pdf_text
26 26. Revise items 3 and 4 in Section 907.2.11.2 to read: "3. Activate directional exit markings that will become apparent in an emergency. 76 pdf_text
26 26. Revise the first paragraph of Section 1810.3.6 to read: "1810.3.6 Splices. Splices shall be constructed so as to provide and maintain true alignment and position of the component parts of the foundation element during installation and subsequent thereto and shall be designed to resist the axial and shear forc moments occurring at the location of the splice during driving and for design load combinations. Where deep founda of different materials or different types are being spliced, splices shall develop the full compressive strength. Where cores are to be spliced, the ends shall be milled or ground to provide full contact and shall be full-depth welded." 173 pdf_text
2603.12.1 2603.12.1 and 2603.12.2, or an engineered design for support of cladding weight. Exceptions: 193 pdf_text
27 27. Delete Section 907.2.11.3. 76 pdf_text
27 27. Revise the definition of "basement" to read: "BASEMENT. A story that is not a story above grade plane." 5 pdf_text
27 27. Add a new Section 903.2.11.6 to read: "903.2.11.6 Shops and storerooms. An automatic sprinkler system shall be installed in all rooms and spaces used as paint shops, wastepaper baling or st other storage uses having a similar degree of combustibility. Exceptions: 70 pdf_text
27 27. Delete Section 403.5.5. 26 pdf_text
27 27. Revise the second sentence of Section 1705.14 to read: "Special inspections shall be based on the permitted construction documents." 161 pdf_text
27 27. Revise Section 1010.3.2 by replacing "an approved" with "a." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 44; Amend Coun. J. 12-14-22, p. 58278, Art. III, § 3; Amend Coun. J. 1-24-2 IV, § 3) 95 pdf_text
27 27. Revise the title and first sentence of Section 1810.3.6.1 to read: "1810.3.6.1 Seismic Design Categories C and D. For structures assigned to Seismic Design Category C or D splices of deep foundation elements shall develop the les 173 pdf_text
27 27. Delete Section 1404.18. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 63) 131 pdf_text
27 27. Revise Section 2308.7.6.1 by replacing "Seismic Design Categories B, C, D and E" with "Seismic Desig B or C." 186 pdf_text
28 28. Insert the following definition: "BED-AND-BREAKFAST ESTABLISHMENT. An entire owner-occupied building, with not more than four stor grade plane, or an owner-occupied dwelling unit containing 11 or fewer guest rooms that are regularly made availabl for hire on a transient basis." 5 pdf_text
28 28. Revise the title and first sentence of Section 1810.3.8.2.2 to read: "1810.3.8.2.2 Seismic reinforcement in Seismic Design Categories C and D. For structures assigned to Seismic Design Category C or D, precast nonprestressed piles shall be reinforced as specif section." 174 pdf_text
28 28. Revise Section 2308.7.11 by deleting "approved." 186 pdf_text
28 28. Add a new Section 903.2.11.7 to read: "903.2.11.7 Telecommunications equipment areas. Every fire area within an existing structure containing a telecommunication equipment area that exceeds 150 square m2) must be equipped with an automatic fire-extinguishing system." 70 pdf_text
28 28. Delete Section 403.5.6. 26 pdf_text
28 28. Revise Section 907.2.12 to read: "907.2.12 High-rise buildings. High-rise buildings shall be provided with an automatic smoke detection system in accordance with Section 907.2.1 communication systems in accordance with Section 907.2.12.2. Exceptions: 76 pdf_text
28 28. Revise Section 1705.14.2 to read: "1705.14.2 Structural member surface conditions. The surfaces shall be prepared in accordance with the permitted construction documents and the written instructions manufacturer. The prepared surface of structural members to be sprayed shall be inspected by the special inspector b application of the sprayed fire-resistant material." 161 pdf_text
29 29. Revise Section 903.2.12 by deleting "Chapter 33 of." 70 pdf_text
29 29. Revise Section 907.2.12.1.1 to read: "907.2.12.1.1 Area smoke detection. Area smoke detectors shall be provided in accordance with this section. Smoke detectors shall be connected to an aut alarm system. The activation of any detector required by this section shall activate the occupant notification applianc accordance with Section 907.5. In addition to smoke detectors required by Sections 907.2.1 through 907.2.9, smoke be located as follows: 76 pdf_text
29 29. Delete the definition of "boarding house." 5 pdf_text
29 29. Revise Section 1810.3.8.2.3 to read: "1810.3.8.2.3 Additional seismic reinforcement in Seismic Design Category D. For structures assigned to Seismic Design Category D, transverse reinforcement shall be in accordance with Section 174 pdf_text
29 29. Revise Section 1705.14.3 to read: "1705.14.3 Application. The substrate shall have a minimum ambient temperature before and after application as specified in the written instr manufacturer. The area for application shall be ventilated during and after application as required by the written instr manufacturer." 161 pdf_text
29 29. Revise Section 403.6 and its subsections to read: "403.6 Elevators. Elevator installation and operation in high-rise buildings shall comply with Chapter 30 and Section 403.6.1. 26 pdf_text
2901.1 2901.1 Scope. The provisions of the Chicago Plumbing Code shall govern the design, construction, erection and installation of plu components, appliances, equipment and systems used in buildings and structures covered by this code. Toilet and bat shall be constructed in accordance with Section 1209. The Chicago Fire Prevention Code, the Chicago Minimum Re Existing Buildings and the Chicago Plumbing Code shall govern the use and maintenance of plumbing components, equipment and systems. The Chicago Building Rehabilitation Code and the Chicago Plumbing Code shall govern th repair, relocation, replacement and addition of plumbing components, appliances, equipment and systems." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 92) CHAPTER 14B-30 CONVEYANCE DEVICES 197 pdf_text
3 3. Revise note e to Table 2306.3(2) by replacing "Seismic Design Category D, E or F" with "Seismic Design Categ 185 pdf_text
3 3. Revise the exceptions to Section 806.2 by deleting "approved." 65 pdf_text
3 3. Revise row 5 of Table 1607.1 to read: 146 pdf_text
3 3. Revise Section 2511.5 by replacing "an approved" with "a." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 87) 191 pdf_text
3 3. Dwelling units and sleeping units in Groups R. 92 pdf_text
3 3. Delete exception 4 to Section 2609.4. 195 pdf_text
3 3. Full geotechnical investigations by a registered geotechnical engineer are not required where exc than 8 feet (2438 mm) below existing grade is not required, a test pit is used for soil classification and ground-water table, and the values used as the basis for design do not exceed the presumptive values i 163 pdf_text
3 3. Revise Section 901.4 by replacing "local fire department" with "Chicago Fire Department." 67 pdf_text
3 3. Revise Section 718.2.6 by replacing "approved wood of natural decay resistance" with "naturally durable wood. 63 pdf_text
3 3. Revise Section 2113.7 to read: "2113.7 Offsets. Where a masonry chimney is constructed with a fireclay flue liner surrounded by one wythe of masonry, the maximu be such that the centerline of the flue above the offset does not extend beyond the center of the chimney wall below t Where the chimney offset is supported by masonry below the offset in accordance with accepted engineering practice maximum offset limitations shall not apply. Each individual corbeled masonry course of the offset shall not exceed t limitations specified in Section 2113.5." 180 pdf_text
3 3. Revise Section 1204.3 to read: "1204.3 Artificial light. Artificial light shall be provided that is adequate to provide an average illumination of 10 footcandles (107 lux) over room at a height of 30 inches (762 mm) above the floor level. Lighting outlets shall be provided as required in Sectio the Chicago Electrical Code. Exception: Within dwelling units, wall switch-controlled receptacles shall be permitted in lieu of lighting out accordance with Section 210.70(A)(1), exception 1 of the Chicago Electrical Code." 123 pdf_text
3 3 Not Permitted 61 pdf_text
3 3. Delete Section 1502.3. 134 pdf_text
3 3. Revise Section 3303.4 to read: "3303.4 Filling and grading. Where a structure has been demolished or removed, the vacant lot shall be filled, where necessary, with clean soil, ci inorganic material and graded to a level not lower than and not more than 12 inches (305 mm) above the level of side or adjoining property, with proper allowance for settlement." 208 pdf_text
3 3. Liquefied petroleum gas systems in accordance with the Chicago Fire Prevention (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 100) 213 pdf_text
3 3. Delete the exception to Section 3104.5.3. 203 pdf_text
3 3. Revise item 3 in Section 1023.5 to read: "3. Security systems covering the interior exit stairway or ramp." 103 pdf_text
3 3 H-4 NS c, d UL 38 pdf_text
3 3. Revise Section 2303.1.4 to read: "2303.1.4 Structural glued cross-laminated timber. Where approved for use, cross-laminated timber shall be manufactured and identified in accordance with ANSI/AP 183 pdf_text
3 3. Revise Section 306.2 to insert, alphabetically: "Tire storage [under 10,000 cubic feet (283 m 3 )]." 20 pdf_text
3 3. Elevators, as required in Section 3003. 27 pdf_text
3 3. Revise Section 904.11.1.4 by replacing "an approved" with "a." 71 pdf_text
3 3. Exterior exit stairways and exterior exit ramps serving occupiable rooftops above portions not more than two stories above grade plane shall have a minimum separation distance of 5 fe 104 pdf_text
3 3. For occupancies in Group R-3 and R-5, and within individual dwelling units in occupancies in Group R-2 of the guard serves as a handrail on the open sides of stairs, the top of the guard shall be not less than 34 inc and not more than 38 inches (965 mm) measured vertically from a line connecting the leading edges of the tr 99 pdf_text
3 3. Delete the last sentence of Section 703.4. 51 pdf_text
3 3. Delete Section 504.1.2. 36 pdf_text
3 3. Equipment, control wiring, power wiring and ductwork shall be located within the separated from the remainder of the building, including other mechanical equipment, b 229 pdf_text
3 3. Delete item 5 in Section 906.1. 73 pdf_text
3 3. Revise Section 1028.3 to read: "1028.3 Exit discharge components. Exterior exit discharge components shall be sufficiently open to the atmosphere so as to minimize the accumulation toxic gases." 105 pdf_text
3 3. In Group R-5 occupancies, the exits, exit access doorways, exit access stairways or exit ac shall be arranged remote from one another so as to minimize the chance of both being blocked fire. 91 pdf_text
3 3. Supervisory service is not required for automatic sprinkler systems in Group R-5 o 67 pdf_text
3 3. Revise exception 2 to Section 2603.3 to read: "2. In cold storage buildings, ice plants, food plants, food processing rooms and similar areas, foam plastic i where tested in a thickness of 4 inches (102 mm) shall be permitted in a thickness up to 10 inches (254 mm) building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1." 192 pdf_text
3 3. Revise Table 414.2.2 by replacing each "1" in the last column with "2". 32 pdf_text
3 3. Within interior exit stairways at every fifth level and every landing for a level numbered w of 5. 76 pdf_text
3 3. Materials and systems required to be installed in accordance with additional manufacturer’s instru prescribe requirements not contained in this code or in standards referenced by this code." 157 pdf_text
3 3. Revise exception 1 to Section 1027.6 to read: "1. Separation from the interior of the building is not required for occupancies, other than Group R-1, in bui not more than two stories above grade plane where a level of exit discharge serving such occupancies is the f above grade plane. 104 pdf_text
3 3. In Group I-1, Condition 2; Group I-2; and ambulatory care facilities, where a pair o swinging doors are installed across a corridor in accordance with Section S101.5.3.1, t not be required to be protected in accordance with Section 716. The doors shall be clos operational tolerances and shall not have a center mullion or undercuts in excess of 3/4 mm), louvers or grilles. The doors shall have head and jamb stops and astragals or rabb edges and, where permitted by the door manufacturer’s listing, positive-latching devic required. 222 pdf_text
3 3. Where egress doors are used in pairs, automatic flush bolts shall be permitted to be used, provided leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware. 94 pdf_text
3 3. Revise Section 3201.4 to read: "3201.4 Drainage. Drainage water collected from a roof, awning, exterior balcony, canopy or marquee, and condensate from mechanic shall not be directed to flow onto or over a public sidewalk." 205 pdf_text
3 3. Revise Section 1803.3.1 by replacing "registered design professional" with "registered geotechnical engineer." 163 pdf_text
3 3. Insert a section to read: " ASHRAE 216 pdf_text
3 3. Where allowed, a change in elevation consisting of a single riser at an entrance or egress door doe handrails. 97 pdf_text
3 3. From a space not more than 250 square feet (23 m 2 ) in area and serving not more than five occu 97 pdf_text
3 3. Dwelling units and sleeping units in multi-story housing shall comply with Section 1107.6. be considered in determining the number of units in a planned development for purposes of thi Affordable units shall also comply with Section 1107.9. 116 pdf_text
3 3. Revise Section 405.7 and its subsections to read: "405.7 Means of egress. Means of egress shall be in accordance with Section 405.7.1. 27 pdf_text
3 3. The fire area has an occupant load of 100 or more and is located on a floor more than four feet (1219 mm lowest level of exit discharge serving such occupancy." 68 pdf_text
3 3. Add a new Section 1105.3 to read: "1105.3 Group I-2 and ambulatory care facilities. In Group I-2 occupancies and Group B ambulatory care facilities at least one accessible entrance shall be protected weather by a canopy or roof overhang. Such entrance shall incorporate a passenger loading zone complying with Sec 111 pdf_text
3 3. A six foot (1829 mm) clear working space shall be provided in front of all panels. 79 pdf_text
3 3. In Group R-2 facilities with Type A units complying with Section 1107.6.2.2.1, an accessib required to connect stories or mezzanines where Type A units, all common use areas serving Ty all public use areas are on an accessible route. This exception does not apply to multi-story ho 112 pdf_text
3 3. Where a less frequent or delayed sampling interval is approved by the fire code official." 82 pdf_text
3 3. Buildings of Type V construction." (Amend Coun. J. 7-24-19, p. 3646, § 32; Amend Coun. J. 2-19-20, p. 14473, Art. II, § 65) 134 pdf_text
3 3. Revise Section 916.5 by replacing "an approved" with "a central." 82 pdf_text
3 3. Revise Section 308.2.4 to read: "308.2.4 Five or fewer individuals receiving custodial care. A facility with five or fewer individuals receiving custodial care shall be classified as Group R-3 provided an autom system is installed in accordance with Section 903.3.1.3." 21 pdf_text
3 3. Doors within individual dwelling units in Groups R-2, R-3 and R-5 other than within Accessible u A units." 94 pdf_text
3 3. Revise Section 1103.2.5 to read: "1103.2.5 Construction sites. Structures, sites and equipment directly associated with the actual processes of construction including, but not limite scaffolding, bridging, materials hoists, materials storage or construction trailers are not required to comply with this or bathing facilities provided for use exclusively by construction personnel on a construction site are not required to this chapter. Temporary pedestrian circulation routes around and adjacent to a construction site shall comply with Ch 110 pdf_text
3 3. The restrictions on door swing shall not apply to doors to rooms or spaces which are not oc spaces. 87 pdf_text
3 3. Revise Section 3202.1.2 to read: "3202.1.2 Vaults and other enclosed spaces. The construction and utilization of vaults and other enclosed spaces below grade shall be subject to Chapter 10-28 of Code." 206 pdf_text
3 3. Trade name or kind of chemical used in treatment. 202 pdf_text
3 3. Revise exception 2 to Section 1011.3 to read: "2. The required headroom clearance shall be not less than 80 inches (2032 mm), and where the nosings of t side of a flight extend under the edge of a floor opening through which the stair passes, the floor opening sha to project horizontally into the required headroom not more than 4 3/4 inches (121 mm) in any of the followi 95 pdf_text
3 3. Approved engineering analysis based on a comparison of opening protective designs having fire protectio 61 pdf_text
3 3. Revise note d to Table 1404.2 to read: "d. 16 ounces per square foot for cold-rolled copper, 12 ounces per square foot for copper shingles and high- yield c 129 pdf_text
3 3. Revise Section 410.2.5 to read: "410.2.5 Proscenium curtain. Where a proscenium wall is required to have a fire-resistance rating, the stage opening shall be provided with a fire 31 pdf_text
3 3. Replace Table 1604.5 as shown: TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES 145 pdf_text
3 3. Delete the exception to Section 420.3. 34 pdf_text
3 3. Revise item 1 in Section 1109.8 to read: "1. An accessible route to a performing area, head tables in banquet rooms and spaces and speaker platforms." 118 pdf_text
3 3. Add a new Section 1808.2.1 to read: "1808.2.1 Factor of safety. Foundation elements shall develop a minimum factor of safety against bearing capacity of 3.0 when routine testing is determine soil properties. Foundation elements shall develop a minimum factor of safety of 2.5 against bearing capac when in-situ testing is used to determine soil properties." 169 pdf_text
3 3. Delete Sections 3306.3 through 3306.9. 209 pdf_text
3 3. Exit access stairways connecting three stories or less serving and contained within a Group R-3 congrega facility or a Group R-4 facility are not required to be enclosed. 101 pdf_text
3 3. Revise Section 1805.1.2 by replacing "an approved" with "a". 165 pdf_text
3 3. Revise exception 2 to Section 1104.3.1 to read: "2. Common use circulation paths, located within employee work areas, that are an integral component of work are shall not be required to be accessible routes." 110 pdf_text
3 3. The exterior walls of other buildings on the same lot with openings that are not protected in accor 102 pdf_text
3 3. Domestic cooking hoods installed and constructed in accordance with section 505 of the C Mechanical Code shall be provided over cooktops or ranges. 34 pdf_text
3 3 I-1, Condition 2 NS d, e UL 38 pdf_text
3 3. Delete Section 1407.6. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 64; Amend Coun. J. 6-25-21, p. 32180, Art. II, § 23) 133 pdf_text
3 3. Revise Section 602.4 and its subsections to read: "602.4 Type IV. Type IV construction is that type of construction in which the exterior walls are of noncombustible materials and the building elements are of solid wood, laminated wood, heavy timber (HT) or structural composite lumber (SCL) with spaces. The minimum dimensions for permitted materials including solid timber, structural glued-laminated timber, composite lumber (SCL), and cross-laminated timber and details of Type IV construction shall comply with the prov section and Section 2304.11. Interior walls and partitions and noncombustible floor and roof assemblies with not less fire-resistance rating or heavy timber complying with Section 2304.11.2.2 shall be permitted. 49 pdf_text
3 3. The aggregate area of a mezzanine within a dwelling unit that is located in a building equip throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3. greater than one-half of the floor area of the room, provided that both: 40 pdf_text
3 3. Revise Section 419.2, excluding the exception, to read: "419.2 Occupancies. Live/work units shall be classified as a Group R-2 or R-5 occupancy. Separation requirements found in Sections 420 not apply within the live/work unit where the live/work unit is in compliance with Section 419. Nonresidential uses th otherwise be classified as either a Group H or S occupancy shall not be permitted in a live/work unit. Live/work units used for the commercial production, sale or distribution of food or drink for consumption on- or off-premises." 33 pdf_text
3 3. Revise Section 905.3.1 to read: "905.3.1 Height. Class III standpipe systems shall be installed throughout buildings which exceed 55 feet in building height or where f stories are above grade plane or two or more stories are basements. Exceptions: 72 pdf_text
3 3. Delete exceptions 2 and 4 to Section 708.4. 58 pdf_text
3 3. A facility within a dwelling unit occupied as a residence by the operator and having eight or fewer receiving such day care shall be classified as a Group R-2, R-3 or R-5 occupancy. 20 pdf_text
3 3. Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling un 98 pdf_text
3 3 A-5 NS UL UL UL UL 38 pdf_text
3 3. The pressure differential is permitted to be measured relative to the outdoor atmosphere on than the following: 230 pdf_text
3 3. Revise the exception to Section 915.1.3 by replacing "an approved location" with "a location that is monitored at when the building is occupied." 81 pdf_text
3 3. Mezzanines or portions thereof are not required to be open to the room in which the mezzanines are locate that the aggregate floor area of the enclosed space is not greater than 10 percent of the allowable mezzanine a 40 pdf_text
3 3. Revise the first paragraph of Section 311.3 to read: "Storage Group S-2 occupancies shall include open or enclosed parking garages, other than repair garages, private g carports. Storage Group S-2 occupancies may also include, with the written approval of the fire code official, buildings used f of noncombustible materials with no more than one layer of combustible packaging or protection. Such products are have a negligible amount of plastic trim, such as knobs, handles or film wrapping. Approved Group S-2 storage uses storage of the following:" 23 pdf_text
3 3. Revise Section 509.3 to read: "509.3 Area limitations. Incidental uses shall not occupy more than 10 percent of the gross floor area of the primary occupancy in which the 47 pdf_text
3 3. Revise item 6 in Section 1603.1.3 to read: "6. Drift surcharge load(s), Pd." 144 pdf_text
3 3. Motor-vehicle-related occupancies shall not be classified as accessory occupancies and shall be se other occupancies in accordance with Section 406." 44 pdf_text
3 3. Revise exceptions 1, 2 and 3 to Section 1015.3 to read: "1. For occupancies in Group R-3 and R-5 not more than three stories above grade plane in height and with dwelling units in occupancies in Group R-2, and outdoor areas of individual dwelling units located not more t stories above grade plane, required guards shall be not less than 36 inches (914 mm) in height measured vert the adjacent walking surfaces. 99 pdf_text
3 3. Photovoltaic and solar thermal equipment. 142 pdf_text
3 3. Revise Section 707.3.10 by deleting "fire walls." 58 pdf_text
3 3. A portion of every loft must have a ceiling height of at least 5 feet (1524 mm), measured from the to the finished ceiling. Portions of a loft with a sloped ceiling measuring less than 3 feet (914 mm) fro floor to the finished ceiling shall not be considered as contributing to the minimum required or maxim area of the loft. 125 pdf_text
3 3. Fire detection and alarm system annunciator. 80 pdf_text
3 3. Revise Section 3001.3 to read: "3001.3 Applicable standards. The design, construction, installation, alteration, repair and maintenance of conveyance devices and their componen conform to the Chicago Conveyance Device Code." 198 pdf_text
3 3. For lintels, 3/4 inch (19 mm) and limited to a maximum span of six feet (1829 mm). 182 pdf_text
3 3. Revise Section 907.1.3 by deleting "and approved." 73 pdf_text
3 3. Revise Section 910.2.1 to read: "910.2.1 Group F-1 or S-1. A mechanical smoke removal system installed in accordance with Section 910.4 shall be installed in buildings and p used as a Group F-1 or S-1 occupancy having more than 50,000 square feet (4645 m2) of undivided area. Exception: Group S-1 aircraft repair hangars." 79 pdf_text
3 3. In Group E occupancies, all regular classrooms shall be provided with natural light in acco 122 pdf_text
3 3. Revise Section 2607.3 to read: "2607.3 Height limitation. Light-transmitting plastics shall not be installed more than 40 feet (12 190 mm) above grade plane." 194 pdf_text
3 3. The longest horizontal dimension of the structure is no more than five times the shortest horizonta of the structure. 149 pdf_text
3 3. The canopy shall have at least one long side open. 218 pdf_text
3 3 A-3 NS UL 38 pdf_text
3 3. The basic design wind speed, V, for use in the design of Risk Category III structures shall be 114 149 pdf_text
3 3. Delete Section 1804.5. 164 pdf_text
3 3. Equipment shall not be refueled while in operation. 214 pdf_text
3 3. Revise Section 3102.8.1.1 to read: "3102.8.1.1 Auxiliary inflation system. In addition to the primary inflation system an auxiliary inflation system shall be provided with sufficient capacity to inflation of the structure in case of primary system failure. The auxiliary inflation system shall operate automatically a loss of internal pressure and when the primary blower system becomes inoperative." 201 pdf_text
3 3. In air traffic control towers, an accessible route is not required to serve the cab and the flo below the cab. 110 pdf_text
3 3. Revise exceptions 11 and 12 to Section 1010.1.1 to read: "11. The minimum clear opening width shall not apply to doors for shower or sauna compartments not requi accessible. 93 pdf_text
3 3. Delete Equation 16-35. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 75) 151 pdf_text
3 3. Add new notes f and g to Table 716.1(2) to read: "f. Two doors or shutters, each with a fire-resistance rating of 3 hours, installed on opposite sides of the same open without a vestibule. One door or shutter shall be automatic and the other shall be either automatic or self-closing. g. Where buildings on both sides of a fire wall are equipped with an automatic sprinkler system in accordance with 61 pdf_text
3 3. Revise the notes to Table 1809.7 by replacing "Seismic Design Category C, D, E or F" with "Seismic Design Cat and "Group R-3" with "Group R-3, R-4 and R-5." Revise the exception to Section 1809.8 by replacing "Group R-3" with "Group R-3, R-4 or R-5." 170 pdf_text
3 3. Operable windows where the openings are provided with window fall prevention devices that com ASTM F2090. 100 pdf_text
3 3. Voice communication systems. 26 pdf_text
3 3. Add a new Section 3301.4 to read: "3301.4 Reuse and reprocessing of construction and demolition site material. Surplus materials and debris resulting from construction and demolition activities shall be reused or reprocessed in a Article XIV of Chapter 11-4 of the Municipal Code." 207 pdf_text
3 3. Delete the exception to Section 1017.3. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 48) 100 pdf_text
3 3. High-rise buildings. A presignal feature shall not be installed in other building types unless approved by the fire code official. Where a pr is provided, a signal shall be annunciated at a constantly attended location acceptable to the fire code official so that notification can be activated in the event of fire or other emergency." 77 pdf_text
3 3. Other approved vented claddings." 129 pdf_text
3 3/4 hour. The exterior wall above the fire wall shall also comply with Sections 602 and 705 based on fire separation Exception: Where the fire wall terminates at the underside of the roof covering or roof deck of the lower roo that: 58 pdf_text
3 3. In each story within a dwelling unit, including basements but not including crawl spaces and unin In dwellings or dwelling units with split levels and without an intervening door between the adjacent l alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower lev one full story below the upper level. 75 pdf_text
3 3. Replace Table 1020.2 as shown: TABLE 1020.2 MINIMUM CORRIDOR WIDTH 101 pdf_text
3 3. Revise Section 1209.3 and its subsections to read: "1209.3 Privacy. Privacy at water closets, urinals and bathing areas shall be provided in accordance with the Chicago Plumbing Code. (Amend Coun. J. 10-7-20, p. 21791, Art. II, § 27) 126 pdf_text
3 3. Revise Section 407.4.4.2 to read: "407.4.4.2 Separation. Care suites shall be separated from other portions of the building, including other care suites, by a smoke barrier co 31 pdf_text
3 3. Outdoor areas only accessed from an individual dwelling unit in Group R-2, R-3 or R-5 oc only have one means of egress and shall not be assigned an occupant load." 86 pdf_text
3 3. Revise Table 1505.1 by changing the value for IIB from "C c" to "B." 136 pdf_text
3 3 to less than 5 53 pdf_text
3 3. The opening between the remote room and the adjoining room shall be parallel to the plan exterior glazed openings, as near as possible to the ceiling and either: 123 pdf_text
3 3. Revise Section 1408.7 by deleting "approved." 133 pdf_text
3 3. Revise exception 1 to Section 705.3 to read: "1. Two or more buildings on the same lot of record in accordance with the exception to Section 503.1.2." 54 pdf_text
3 3. Revise exception 1 to Section 406.2.4 to read: "1. Asphalt parking surfaces shall be permitted at ground level for open parking garages and carports." 28 pdf_text
3 3. Revise Section 1006.2.1 by replacing "values listed in Table 1006.2.1" with "values listed in Table 1006.2.1 or th the space exceeds 4,000 square feet (372 m2)." 87 pdf_text
3 3. Revise Section 704.11 to read: "704.11 Bottom flange protection. Fire protection is not required at the bottom flange of lintels, shelf angles and plates, spanning not more than 6 feet 4 mm) whether part of the primary structural frame or not, and from the bottom flange of lintels, shelf angles and plate the primary structural frame, regardless of span." 52 pdf_text
3 3. Fire walls shall be permitted to terminate at the interior surface of noncombustible exterior sheath building on each side of the fire wall is protected by an automatic sprinkler system installed in accord 57 pdf_text
3 3. Spiral stairways constructed in accordance with Section 1011.10. 96 pdf_text
3 3. Revise exception 1 to Section 404.6 by replacing "smoke partition" with "smoke-resistive barrier." 27 pdf_text
3 3. Delete Section 3007.3. 200 pdf_text
3 3. Within or serving a building of Group R-3 or R-5 occupancy. 96 pdf_text
3 3. Revise Section 3002.4 to read: "3002.4 Elevator car to accommodate ambulance stretcher in new buildings. Where elevators are provided in new buildings and additions with six or more stories above grade plane or two or m basements, not less than one elevator shall be provided for fire department emergency access to all stories. The eleva of such a size and arrangement to accommodate an ambulance stretcher 24 inches by 84 inches (610 mm by 2134 m than 5-inch (127 mm) radius corners, in the horizontal, open position and shall be identified by the international sym emergency medical services (star of life). The symbol shall be not less than 3 inches (76 mm) in height and shall be on both sides of the hoistway door frame." 198 pdf_text
3 3. Revise Section 912.2.2 by replacing "an approved" with "a" and deleting the last sentence. 81 pdf_text
3 3. Interior nonbearing walls weighing 15 psf (73.5 N/ m2) or less. 159 pdf_text
3 3. Picnic facilities. 119 pdf_text
3 3. Revise the exception to Section 1106.5 to read: "Exceptions: 112 pdf_text
3 3. Group R buildings that are four stories or less above grade plane." 56 pdf_text
3 3. Where the parking garage is in a basement." 69 pdf_text
3 3. Revise the exceptions to Section 3005.4 to read: "Exceptions: 199 pdf_text
3 3. More than 10 percent of the soil particles are less than 5 micrometers in size, determined in accord ASTM D422. 163 pdf_text
3 3. The exterior face of an adjacent building on the same lot. 43 pdf_text
3 3. Buildings of Group R-3, R-4 or R-5 occupancy using the provisions of AISI S230 (includi containing up to 3 dwelling units). 148 pdf_text
3 3. Such observation is required by the registered design professional responsible for the stru 157 pdf_text
3 3. Revise Section 715.4 by replacing "an approved" with "a." 61 pdf_text
3 3. Revise Section 1402.5 to read: "1402.5 Vertical and lateral flame propagation. Exterior walls on buildings of Type I, II, III or IV construction that are greater than 40 feet (12 192 mm) in height ab plane and contain a combustible water-resistive barrier or air barrier shall be tested in accordance with and comply acceptance criteria of NFPA 285. For the purposes of this section, fenestration products, flashing of fenestration pro flashing and accessories at other locations, including through-wall flashings, shall not be considered part of the water barrier. Exceptions: 128 pdf_text
3 3. Insert new Sections 3308.3 and 3308.4 to read: "3308.3 Debris. Debris shall not be allowed to accumulate in the public way in violation of Section 7-28-395 of the Municipal Code. 210 pdf_text
3 3. Revise Section 712.1.5.2 by replacing "an approved material or system" with "a material or system engineered." 59 pdf_text
3 3. Revise Section 1403.4 by replacing "steel framing" with "metal framing." 128 pdf_text
3 3. Buildings with an occupancy in Group A-5 in accordance with Section 303.1. 76 pdf_text
3 3. Within or serving only dwelling units that are not required to be Type B units." 93 pdf_text
3 3. Educational (see Section 305): Groups E-1 and E-2. 19 pdf_text
3 3. Delete Section 911.1.3. 80 pdf_text
3 3. A detached private garage, not more than one story and 12 feet (3658 mm) in height, nor more th feet (60 m2) in area, located on the same lot with a building of Group R-5 occupancy. 219 pdf_text
3 3. Group A occupancies with an aggregate occupant load of 300 or more persons shall be separated f main occupancies by construction providing a fire-resistance rating of not less than 2 hours in buildin protected throughout by an automatic sprinkler system in accordance with Section 903.3.1.1. 45 pdf_text
3 3. Within individual dwelling units in Group R occupancies." 32 pdf_text
3 3. Delete Section 1703.3. 155 pdf_text
3 3. Rooms containing bathtubs, showers, spas and similar bathing fixtures shall be mechanical accordance with the Chicago Mechanical Code. 120 pdf_text
3 3 to less than 5 e Unprotected, Nonsprinklered (UP, NS) Not Permit Unprotected, Sprinklered (UP, S) i 55 pdf_text
3 3. Revise Section 2407.1.2 to read: "2407.1.2 Structural glass baluster panels. Guards with structural glass baluster panels shall be installed with an attached top rail or handrail. The top rail or ha supported by not fewer than three glass baluster panels, or shall be otherwise supported to remain in place should on panel fail. Exception: An attached top rail or handrail is not required where the glass baluster panels are laminated glas more glass plies of equal thickness and of the same glass type. The panels shall be tested to remain in place a following impact or glass breakage in accordance with ASTM E2353." 189 pdf_text
3 3. Revise the first sentence of Section 717.4 to read: "Fire and smoke dampers shall be provided with a means of access that is large enough to allow inspection and main damper and its operating parts." 62 pdf_text
3 3. Throughout buildings containing Group E-2 occupancies. Exception: Where every room or space in a Group E-2 occupancy normally subject to client occupancy, othe rooms, has not less than one door leading directly to an exit or directly to the outside of the building." 68 pdf_text
3 3. At elevated walking surfaces for access to and use of electrical, mechanical or plumbing systems 99 pdf_text
3 3. To provide access to the mezzanine or second story above grade plane of a two-story building or t or mezzanine of a one-story building, other than a shopping mall, shopping center, or the professional health care provider, where each story is not more than 3,000 square feet (279 m2)." 118 pdf_text
3 3. On buildings of Type III, IV or V construction, the exterior walls of mechanical penthous separation distance greater than 5 feet (1524 mm) and less than 20 feet (6096 mm) shall be pe not less than a 1-hour fire-resistance rating or a lesser fire- resistance rating as required by Ta buildings of Type III, IV or VA construction, the exterior walls of mechanical penthouses wit separation distance of 20 feet (6096 mm) or greater shall be permitted to be of heavy timber c complying with Sections 602.4 and 2304.11 or noncombustible construction and shall not be r a fire-resistance rating." 139 pdf_text
3 3. Heat alarms and heat detectors shall be installed in accordance with the manufacturer's instruction 76 pdf_text
3 3,0 S1 UL UL 41 pdf_text
3 3. Revise Section 706.3, including the exception, to read: "706.3 Materials. Fire walls shall be of noncombustible materials." 57 pdf_text
3 3. Fans, dampers and other operating equipment in their on or open status – GREEN. 226 pdf_text
3 3. Passenger terminals. 111 pdf_text
3 3. Recommended driving installation acceptance criteria. 163 pdf_text
3 3. Foam plastic used as interior wall or ceiling finish or interior trim in plenum-served spaces flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in ac ASTM E84 or UL 723 at the maximum thickness and density intended for use, where it is sep airflow in the plenum by not less than a 1-inch (25 mm) thickness of masonry or concrete." 193 pdf_text
3 3. Revise item 1 (including the exception) in Section 403.2.1.1 to read: "1. For buildings not greater than 400 feet (122 m) in building height, the fire-resistance rating of the buildi Type IA construction, other than the primary structural frame, shall be permitted to be reduced to the minim resistance ratings for the building elements in Type IB." 24 pdf_text
3 3. Revise exception 2 to Section 1009.3.3 by replacing "an automatic sprinkler system" with "a supervised automati system." 92 pdf_text
3 3. Delete Section 2308.2.4. 185 pdf_text
3 3. ON-OFF or OPEN-CLOSE control over smoke control and other critical equipment associ or smoke emergency and that can only be controlled from the fire fighter’s control panel. Exceptions: 226 pdf_text
3 3. Revise Section 1908.7 by replacing "approved" with "permitted." 177 pdf_text
3 3. Supply openings shall be sized for at least one-half the exhaust capacity. 78 pdf_text
3 3. Revise Equation 5-2 by deleting the second sentence from the description of Sa. 43 pdf_text
3 3. Revise item 5 of Section 2606.7 to read: "5. Interior exit stairways, interior exit ramps and exit passageways. 194 pdf_text
3 3. If any room in a building has a sloped ceiling, the prescribed ceiling height for the room is one-half the area thereof. Any portion of the room measuring less than 5 feet (1524 mm) from floor to the ceiling shall not be included in any computation of the minimum area thereof. 125 pdf_text
3 3. Where enclosed elevator lobbies are not provided, in corridors adjoining elevators." 76 pdf_text
3 3. Revise Section 2111.14.3 to read: "2111.14.3 Exterior air intake. The exterior air intake shall be capable of providing all combustion air from the exterior of the building. The exterior shall not be located within a garage, attic, basement or crawl space nor shall the air intake be located at an elevation firebox. The exterior air intake shall be covered with a corrosion-resistant screen of 1/4-inch (6.4 mm) mesh." 179 pdf_text
3 3. Means of egress components serving a single basement, the first story above grade second story above grade plane." 103 pdf_text
3 3. Revise the definition of "accessible route" to read: "ACCESSIBLE ROUTE. A continuous, unobstructed path that complies with Chapter 11 connecting all accessible spaces of a building or facility. Interior accessible routes may include corridors, floors, ramps, elevators, lifts, skywa and clear floor space at fixtures. Exterior accessible routes may include parking access aisles, curb ramps, crosswalk ways, pedestrian walkways, ramps, and lifts." 3 pdf_text
3 3. Delete Sections D101.1.1. 218 pdf_text
3 3. Revise Section 508.2.3 to read: "508.2.3 Allowable building area. The allowable area of the building shall be based on the applicable provisions of Section 506 for the main occupancy building. Aggregate accessory occupancies shall not occupy more than 25 percent of the floor area of the story nor m percent of the total floor area of the main occupancy in which they are located and shall not exceed the tabular area v nonsprinklered buildings in Table 506.2 for each such accessory occupancy. Exception: The building official and fire code official may jointly approve accessory occupancies exceeding and 25 percent limits when in their opinion such accessory occupancies do not unduly increase the hazard." 44 pdf_text
3 3. Revise Section 505.2.1.1 by replacing "two-thirds" with "one-half." 40 pdf_text
3 3. Group A-2, A-3 and A-4 occupancies with an occupant load of more than 1,000. 82 pdf_text
3 3. Revise Sections 2702.1.4 and 2702.1.5 by replacing "in this code" with "in this code or the Chicago Electrical C 196 pdf_text
3 3. The seismic force-resisting system of wood-frame buildings of light-frame construction that confo provisions of Section 2308 are not required to be analyzed as specified in this section. 152 pdf_text
3 3. In every exit passageway, at the entrance from the exit passageway to other areas of a building. 72 pdf_text
3 3. Delete Section 2304.10.5.2. 184 pdf_text
3 3. Revise item 13 in Section 603.1 to read: "13. Combustible exterior wall coverings, exterior balconies and similar projections and bay or oriel windo accordance with Chapter 14 and Section 705.2." 49 pdf_text
3 3. Approved calculations in accordance with Section 722. 51 pdf_text
3 3 A-4 NS UL 38 pdf_text
3 3. Revise Section 1406.7 by deleting "approved." 132 pdf_text
3 3. Replace each occurrence of "ASME A17.1/CSA B44" with "Chapter 3 of the Chicago Conveyance Device Code. 2 pdf_text
3 3. Unoccupied rooftop structures shall not be considered in determining building height in ac 17 pdf_text
3 3. A public right-of-way. 13 pdf_text
3 3. Revise Section 1504.6 to read: "1504.6 Physical properties. Roof coverings installed on low-sloped roofs in accordance with Section 1507 shall demonstrate physical integrity ov life of the roof based on 2,000 hours of exposure to accelerated weathering tests conducted in accordance with AST ASTM G154 or ASTM G155. Those roof coverings that are subject to cyclical flexural response due to wind loads s demonstrate any significant loss of tensile strength for unreinforced membranes or breaking strength for reinforced when tested as herein required." 135 pdf_text
3 3. Revise Section 1704.2.3 by replacing "Section 107.1" with "Section 411.1 of the Chicago Construction Codes Ad Provisions." 156 pdf_text
3 3 A-2 NS UL 38 pdf_text
3 3. Revise Section 722.5.2.1.2 by replacing "approved" with "tested." 63 pdf_text
3 3. Special inspections and tests are not required for portions of structures designed and constr accordance with the cold-formed steel light-frame construction provisions of Section 2211.1.2 conventional wood light-frame construction provisions of Section 2308. 155 pdf_text
3 3. The toilet room shall not contain any fuel-fired equipment or appliances." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 49; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 24; Amend Coun. J. 1-24-24, IV, § 4) 102 pdf_text
3 3. For anchored masonry or stone veneer installed over foam sheathing, refer to Section 1404 193 pdf_text
3 3. Delete Section 1008.2.3. 92 pdf_text
3 3. Revise exception 1 to Section 2406.4.6 to read: "1. The side of a stairway, landing or ramp that has a guard complying with the provisions of Sections 1015 and 16 188 pdf_text
3 3. High-pressure decorative exterior-grade compact laminate (HPL) systems complying with 131 pdf_text
3 3. Revise the last sentence of Section 1613.3 to read: "In structures assigned to Seismic Design Category C or D, ballasted nonpenetrating systems shall be designed to ac seismic displacement determined by nonlinear response-history or other engineering analysis or shake-table testing, motions consistent with ASCE 7 lateral and vertical seismic forces for nonstructural components on roofs." 153 pdf_text
3 3. Revise note k to Table 307.1(1) to replace "approved" with "approved." 20 pdf_text
3 3. Revise Section 1509.4 to replace ""deck" with "roof deck." 138 pdf_text
3 3. Delete Table 1806.2. 166 pdf_text
3 3 I-1, Condition 1 NS d, e UL 38 pdf_text
3 3. An imaginary line between two buildings on the same lot. The distance shall be measured at right angles from the face of a wall or edge of a building element." 9 pdf_text
3 3. Butler-Hoy Criterion. 172 pdf_text
3 3. A limited-use limited-application elevator or a wheelchair lift complying with the Conveyance Device Code is provided. 117 pdf_text
3 3. Revise Section 3004.2.1 to read: "3004.2.1 Floor openings. Escalator floor openings shall comply with Section 712." 199 pdf_text
3 3. Revise the second sentence of Section 713.13.1 to read: "A single shaft enclosure shall be permitted to contain recycling and waste chutes." 60 pdf_text
3 3. Enclosed exit access stairways and ramps and all other shafts: A/Aw = 0.00150 221 pdf_text
3 3. Revise exception 1 to Section 1005.3.2 by deleting "and an emergency voice/alarm communication system in acc 87 pdf_text
3 3. For anchored masonry veneer or anchored stone veneer installed over foam sheathing, refe 193 pdf_text
3 3. Delete the exception to Section 3105.3. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 95) 203 pdf_text
3 3. Delete the exception to Section 903.2. 67 pdf_text
3 3. Revise the last sentence of Section 1003.5 before the exceptions to read: "Where a ramp is used for a difference in elevation that is 6 inches (152 mm) or less, it shall be equipped with either floor finish materials that contrast with adjacent floor finish materials." 85 pdf_text
3 3. Revise Section 2405.4 to read: "2405.4 Framing. In Type I and II construction, sloped glazing and skylight frames shall be constructed of noncombustible materials. I where acid fumes deleterious to metal are incidental to the use of the buildings, pressure- treated wood or other nonc materials may be approved for sashes and frames. Framing supporting sloped glazing and skylights shall be designed tributary roof loads in Chapter 16. Skylights set at an angle of less than 45 degrees (0.79 rad) from the horizontal pla mounted not less than 8 inches (203 mm) above the plane of the roof on a curb constructed as required for the frame. shall not be installed in the plane of the roof where the roof pitch is less than 45 degrees (0.79 rad) from the horizont Exception: Installation of a skylight without a curb shall be permitted on roofs with a minimum slope of 14 d units vertical in 12 units horizontal) in Group R-3 and R-5 occupancies. Unit skylights installed in a roof with than 14 degrees (0.25 rad) shall be mounted not less than 4 inches (102 mm) above the plane of the roof on a constructed as required for the frame unless otherwise specified in the manufacturer’s installation instructions 188 pdf_text
3 3. Installation and anchorage of piping systems designed to carry hazardous materials and the mechanical units in structures assigned to Seismic Design Category C or D. 160 pdf_text
3 3. Revise Table 1507.2.8.2 to delete the rows for lead, lead-coated copper, lead-coated high-yield copper, and paint 136 pdf_text
3 3. Revise Section E103.1 to read: 219 pdf_text
3 3. Delete Section 1029.3. 105 pdf_text
3 3. Deep foundation elements supporting the concrete foundation wall of Group R-3, R-4, R-5 occupancies not exceeding two stories of light-frame construction shall be permitted to be rein required by rational analysis but with not less than two No. 4 bars, without ties or spirals, whe cracking moment determined in accordance with Section 1810.3.9.1 exceeds the required mo determined using the load combinations with overstrength factor in Section 2.3.6 or 2.4.5 of A soil provides adequate lateral support in accordance with Section 1810.2.1. 174 pdf_text
3 3 M NS UL 38 pdf_text
3 3. Revise Section 1107.5 to read: "1107.5 Group I. Accessible units, Type B units and units with communication features shall be provided in Group I occupancies in ac Sections 1107.5.1 through 1107.5.5 and Appendix E." 113 pdf_text
3 3. Revise Table 1807.1.6.2 by: a. Deleting all columns for 30 and 45 psf per foot; b. Deleting note d. 168 pdf_text
3 3. Revise item 4 in Section 1202.3 to read: "4. Any air-impermeable insulation shall be a Class II vapor retarder or shall have a Class II vapor retarder coating direct contact with the underside of the insulation." 120 pdf_text
3 3. Where open or spaced wood veneers (without concealed spaces) are used, they shall not project more tha (610 mm) from the building wall." 129 pdf_text
3 3. Revise Section 1705.2.1 by deleting "in buildings, structures and portions thereof." 157 pdf_text
3 3. Delete Section 3302.3. 208 pdf_text
3 3. Delete Section 1013.2. 98 pdf_text
3 3. Revise exception 3.1 to Section 412.2.3.2 to read: "3.1. Voice communication systems control units." 32 pdf_text
3 3. Automatic fire detection systems. 27 pdf_text
3 3. Revise Table 1405.1.1.1.2 by deleting all entries for a fire separation distance of 15 feet or less, and revising the feet to read "greater than 15." (Amend Coun. J. 12-14-22, p. 58278, Art. III, § 7) 132 pdf_text
3 3. Revise Section 1605.1.1 by replacing "registered design professional" with "registered geotechnical engineer." 146 pdf_text
3 3. Limited non-structural elements of material not less fire resistive than untreated wo composites that comply with ASTM D7032 where approved by the building official. 141 pdf_text
3 3. Alternative plans for the visitable detached single-family dwellings required by Section 1107.8.4, showing accessible features that comply with the requirements for a Type A unit. 116 pdf_text
3 3. Revise Section 803.15.1 by replacing "1 3/4 inches (44 mm)" with "1 3/4 inches (44 mm) in depth." 65 pdf_text
3 3. Steel in compression Cores within concrete-filled pipes or tubes 171 pdf_text
3 3. Revise Section 1510.3 to read: "1510.3 Tanks. Tanks having a capacity of more than 500 gallons (1893 L) located on the roof deck of a building shall be supported reinforced concrete, steel or heavy timber construction complying with Section 2304.11 provided that, where such su located in the building above the lowest story, the support shall have a fire-resistance rating as required for Type IA 139 pdf_text
3 3. Tubing shall be identified by appropriately documented coding. 225 pdf_text
3 3. Revise Section 1810.2.3 to read: "1810.2.3 Settlement. The settlement of a single deep foundation element or group thereof shall be estimated based on accepted engineerin predicted settlement shall cause neither harmful distortion of, nor instability in, the structure, nor cause any element t beyond its capacity." 170 pdf_text
3 3. Revise Section 503.1.2 to read: "503.1.2 Buildings on same lot. Two or more buildings on the same lot shall be regulated as separate buildings. Exception: Two or more buildings on the same lot of record may be considered as portions of one building building height and number of stories above grade plane of each building and the aggregate building area of are within the limitations specified in Sections 504 and 506. The provisions of this code applicable to the agg shall be applicable to each building." 36 pdf_text
3 3. Revise Table 1004.5 by changing the value for "Business areas" from "150 gross" to "100 net." 85 pdf_text
3 3. Add a new Section 2211.3 to read: "2211.3 Vertical shaft enclosures in buildings greater than 55 feet in height. In buildings of cold-formed steel light-frame construction greater than 55 feet (19.8 m) in building height, shaft encl by Section 713 to have a fire-resistance rating greater than 1 hour shall be constructed of structural masonry or conc 182 pdf_text
3 3. In a building where a multistory unit is located above another unit, an accessible route to t not required if a shaft or unenclosed open well is provided to accommodate the future installat residential elevator complying with the Chicago Conveyance Device Code, or if a limited-use application elevator complying with the Chicago Conveyance Device Code or a wheelchair lift with the Chicago Conveyance Device Code is provided. Where a shaft or unenclosed open well is provided, the construction shall be structurally suffic future installation of the elevator or lift without any additional reinforcement or alteration of st elements. Conduit for future electrical wiring and power for operation of the elevator or lift sh provided. Where a shaft is provided, the space provided for the shaft is not restricted from bei other purposes before the elevator or wheelchair lift is installed. The floor openings within the restricted from being in-filled with flooring provided that the in-fill flooring can be removed a installation of the elevator or lift without additional reinforcement or alteration of other structu 116 pdf_text
3 3. Revise exception 2 to Section 714.4.2 by replacing "any material" with "any material allowed by the Chicago Ele 60 pdf_text
3 3. Add a new Section 1609.1.2 to read: "1609.1.2 Special investigations. Special investigations shall be required to determine wind loads for buildings and other structures with a mean roof exceeding 400 feet (122 m). Special investigations shall be required to determine wind loads for buildings and other a mean roof height of 400 feet (122 m) or less and having irregular shapes, response characteristics or site locations or channeling effects that warrant special consideration." 149 pdf_text
3 3. Revise the exception to Section 2610.4 to read: "Exception: The area limitation shall not apply where the building is equipped throughout with an automatic sprinkl accordance with Section 903.3.1.1." 195 pdf_text
3 3. Generator, transformer and switchboard rooms separated from the remainder of the building by w floor/ceiling or roof/ceiling assemblies having a fire-resistance rating of not less than 2 hours. 70 pdf_text
3 3. Revise Section 303.4 to replace "Indoor tennis courts (without spectator seating)" with "Indoor sports and fitness (without spectator seating)." 19 pdf_text
3 (cont. 2) RISK CATEGORY NATURE OF OCCUPANCY I Structures that represent a low hazard to human life in the event of failure, including but not limited to: • Agricultural buildings. • Minor storage structures. II Structures except those listed in Risk Categories I, III and IV. III Structures that represent a substantial hazard to human life in the event of failure, including but not limited to: • Buildings containing one or more Group A occupancies with a combined occupant load in Group A occupancies great • Buildings containing Group E occupancies with an occupant load greater than 500.a • Buildings containing Group I-2, Condition 1 occupancies with 50 or more care recipients. • Buildings containing Group I-2, Condition 2 occupancies not providing emergency surgery or emergency treatment. • Buildings containing Group I-3 occupancies. • Any other building with an occupant load greater than 5,000.a • Power-generating stations, water treatment facilities for potable water, wastewater treatment facilities and other publi structures not included in Risk Category IV. • Structures not included in Risk Category IV containing quantities of toxic or explosive materials that exceed maximu quantities per control area as given in Table 307.1(1) or 307.1(2) or per outdoor control area in accordance with Fire Prevention Code; and are sufficient to pose a threat to the public if released.b IV Structures designated as essential facilities, including but 145 pdf_text
3 (cont. 3) not limited to: • Buildings containing Group I-2, Condition 2 occupancies providing emergency surgery or emergency treatment. • Buildings containing fire, rescue, ambulance and police stations and emergency vehicle garages. • Buildings containing earthquake, hurricane or other emergency shelters. • Designated emergency preparedness, communications and operations centers and other structures required for emerg • Power-generating stations and other utility structures providing emergency backup for Risk Category IV structures. • Structures containing quantities of highly toxic materials that: exceed maximum allowable quantities per control area Table 307.1(2) or per outdoor control area in accordance with the Chicago Fire Prevention Code; and are suffici threat to the public if released.b • Aviation control towers, air traffic control centers and emergency aircraft hangars. • Structures having critical public safety or national defense functions. • Water storage and pump structures required to maintain water pressure for fire suppression. 145 pdf_text
3 (cont. 4) a. Occupant load shall be determined in accordance with Table 1004.5. b. Where approved by the fire code official, the classification of structures as Risk Category III or IV based on their quantities of toxic, highly toxic or ex is permitted to be reduced to Risk Category II, provided that it can be demonstrated by a hazard assessment in accordance with Section 1.5.3 of release of the hazardous materials is not sufficient to pose a threat to the public. 145 pdf_text
3.1 3.1. Revise Section 712.1.7 to read: "712.1.7 Atriums. Atriums complying with Section 404 that connect two or more stories in a Group I-2 or Group I-3 occupancy or thre stories in any other occupancy shall be allowed. Exceptions: 59 pdf_text
3.1 3.1. Except for enclosed closets and bathrooms, the mezzanine shall be open to the ro such mezzanine is located. 40 pdf_text
3.1 3.1. If open and unobstructed, shall have an area at least 8 percent of the floor area of room or 25 square feet (2.32 m2), whichever is greater. 123 pdf_text
3.1 3.1. The fire floor. 230 pdf_text
3.1 3.1. Delete exception 2 to Section 1005.3.2. 87 pdf_text
3.1 3.1. Revise Table 414.2.2 by replacing the rows for "below grade plane" as follows: 33 pdf_text
3.1 3.1. In Group R-3 and R-5 occupancies. 96 pdf_text
3.2 3.2. Within dwelling units in Group R-2 occupancies. 96 pdf_text
3.2 3.2. The two floors immediately below the fire floor. 230 pdf_text
3.2 3.2. If equipped with transparent or translucent glazing, shall have a net glazed area at percent of the floor area of the remote room or 30 square feet (2.8 m2), whichever is gr 123 pdf_text
3.2 3.2. Delete the exception to Section 414.2.4. 33 pdf_text
3.2 3.2. The opening to the room shall be unobstructed except for walls not more than 48 mm) in height, columns and posts." 40 pdf_text
3.3 3.3. In interior and exterior stairways in Group R-2 occupancies serving only units that are not requir Accessible units or Type A units. 96 pdf_text
3.3 3.3. The floor immediately above the fire floor. 230 pdf_text
3.4 3.4. In Group U occupancies that are accessory to a Group R-3 occupancy or accessory to individual in Group R-2 occupancies." 96 pdf_text
3.785 3.785 L, 1 cubic foot = 0.0283 m 3. a. Telecommunication equipment areas over 150 square feet require an automatic fire extinguishing system in accordance with section 903.2.11.7. 47 pdf_text
30 30. Revise the title and first sentence of Section 1810.3.8.3.3 to read: "1810.3.8.3.3 Seismic reinforcement in Seismic Design Category D. For structures assigned to Seismic Design Category D, precast prestressed piles shall have transverse reinforcement i with the following:" 174 pdf_text
30 30 or greater Unprotected, Nonsprinklered (UP, NS) No Limi Unprotected, Sprinklered (UP, S) i No Limi Protected (P) No Limi 55 pdf_text
30 30. Revise Section 903.3.1.1.1 to read: "903.3.1.1.1 Exempt locations. Automatic sprinklers shall not be required in the following rooms or areas where such rooms or areas are protected w automatic fire detection system in accordance with Section 907.2 that will respond to visible or invisible particles of Sprinklers shall not be omitted from a room merely because it is damp, of fire-resistance-rated construction or contai equipment. 70 pdf_text
30 30. Delete Section 907.2.12.1.2. 76 pdf_text
30 30,000 N H-5 NS c, d UL UL 42 pdf_text
30 30 degrees (0.52 rad) from the vertical. Exceptions: 96 pdf_text
30 30 feet (9144 mm) from an abutting property line or an assumed property line shall comply with Table 601. Exception: In the case of one-story buildings that are 2,000 square feet (186 m2) or less in area, exterior wall than 15 feet (4572 mm) from an abutting property line or an assumed property line need only comply with T 218 pdf_text
30 30. Revise Section 1705.14.4 by replacing "approved fire-resistance design" with "permitted construction documen 161 pdf_text
30 30. Revise the definition of "boiling point" to read: "BOILING POINT. As defined in Chapter 2 of the Chicago Fire Prevention Code." 5 pdf_text
30 (cont. 2) For SI: 1 foot = 304.8 mm. UP, NS = Unprotected openings in buildings not equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. UP, S = Unprotected openings in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. P = Openings protected with an opening protective assembly in accordance with Section 705.8.2. a. Values indicated are the percentage of the area of the exterior wall, per story. b. For the requirements for fire walls of buildings with differing heights, see Section 706.6.1. c. For openings in a fire wall for buildings on the same lot, see Section 706.8. d. [Reserved.] e. Unprotected openings shall not be permitted for openings with a fire separation distance of less than 15 feet for Group H-2 and H-3 occupancies. f. [Reserved.] g. The area of openings in an open parking structure with a fire separation distance of 10 feet or greater shall not be limited. h. [Reserved.] i. Not applicable to Group H-1, H-2 and H-3 occupancies. j. [Reserved.] k. For openings between S-2 parking garage and Group R-2 building, see Section 705.3, Exception 2. TABLE 705.8(2) MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEG OPENING PROTECTION FOR PRIVATE GARAGES AND GROUP R-2, R-3, R-4 AND R-5 OCCUPANCIES UP STORIES ABOVE GRADE PLANE a 55 pdf_text
3002.11 3002.11 Sprinkler locations. Automatic sprinklers shall not be installed in elevator machine rooms, elevator machinery spaces, control rooms, con elevator hoistways, except sprinklers shall be installed to protect the bottom of the pit in newly-installed sprinkler sy 198 pdf_text
305.1 305.1 Educational Group E. Educational Group E occupancy includes, among others, the use of a building or structure, or a portion thereof, for e purposes through the 12th grade or to provide day care services to children. 19 pdf_text
305.2 305.2 Educational Group E-1. Educational Group E-1 occupancy includes the use of a building or structure, or a portion thereof, to educate six or three years of age or older, at any one time, through the 12th grade. Exception: Classrooms and auditoriums, which are accessory to an assembly occupancy and have occupant l than 100 per room or space, shall be classified as Group A-3 occupancies. 20 pdf_text
305.3 305.3 Educational Group E-2. Educational Group E-2 occupancy includes the use of a building or structure, or a portion thereof, for providing supe personal care services for fewer than 24 hours per day to more than three children. Exceptions: 20 pdf_text
31 31. Revise the title and first sentence of Section 1810.3.8.3.4 to read: "1810.3.8.3.4 Axial load limit in Seismic Design Categories C and D. For structures assigned to Seismic Design Category C or D, the maximum factored axial load on precast prestressed to a combination of seismic lateral force and axial load shall not exceed the following values:" 174 pdf_text
31 31. Revise the definition of "building" to read: "BUILDING. Any structure utilized or intended for supporting or sheltering any occupancy. Except for purposes of single structure may be divided into two or more buildings by fire walls." 5 pdf_text
31 31. Revise Section 1705.14.5 by replacing "approved fire-resistance design" with "permitted construction documen 161 pdf_text
31 31. Delete Section 903.3.1.1.2. 70 pdf_text
31 31. Revise Section 907.2.12.2 to read: "907.2.12.2 Voice communication systems. Voice communication systems shall be provided in accordance with Sections 907.2.12.2.1 through 907.2.12.2.3. 76 pdf_text
310.1 310.1 Residential Group R. Residential Group R occupancy includes, among others, the use of a building or structure, or a portion thereof, for sl purposes when not classified as an Institutional Group I. 22 pdf_text
310.2 310.2 Residential Group R-1. Residential Group R-1 occupancies contain dwelling units or sleeping units where the occupants are primarily transi including: Hotels with accommodations for more than 10 transient occupants Congregate living facilities with accommodations for more than 10 transient occupants Temporary overnight shelters 22 pdf_text
310.3 310.3 Residential Group R-2. Residential Group R-2 occupancies contain one or more sleeping units or more than three dwelling units (including li where the occupants are primarily permanent in nature, including: Apartment houses (including condominium and cooperative apartments) Congregate living facilities (nontransient) with more than 16 occupants Townhouses 22 pdf_text
310.4 310.4 Residential Group R-3. Residential Group R-3 occupancies where the occupants are primarily permanent in nature and not classified as Grou 22 pdf_text
310.4.1 310.4.1 Care facilities within a dwelling. Care facilities for five or fewer individuals receiving care that are within a single-family dwelling are permitt with the requirements for Group R-5, provided an automatic sprinkler system is installed in accordance with 22 pdf_text
310.5 310.5 Residential Group R-4. Residential Group R-4 occupancy shall include buildings, structures or portions thereof for more than five but not m individuals, excluding staff, who reside on a 24-hour basis in a supervised residential environment and receive custo Buildings of Group R-4 shall be classified as one of the occupancy conditions specified in Section 310.5.1 or 310.5.2 shall include, but not be limited to, the following: Alcohol and drug abuse treatment facilities Assisted living facilities Congregate care facilities Group homes Halfway houses Residential board and care facilities Social rehabilitation facilities Group R-4 occupancies shall meet the requirements for construction as defined for Group R-3, except as otherwise p this code. 22 pdf_text
310.5.1 310.5.1 Condition 1. This occupancy condition shall include buildings in which all individuals receiving custodial care are capable to an emergency situation to complete building evacuation without any assistance. 22 pdf_text
310.5.2 310.5.2 Condition 2. This occupancy condition shall include buildings in which there are any individuals receiving custodial care 22 pdf_text
310.6 310.6 Residential Group R-5. Residential Group R-5 occupancy shall include buildings with no more than four stories above grade plane containi three dwelling units (including live/work units), with or without an attached private garage, and no other occupancy, dwelling unit is primarily occupied on a non-transient basis by a single household. Group R-5 shall also include acce buildings with no more than two stories above grade plane located on the same lot as Group R-5 dwelling units. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 5) 23 pdf_text
3103.1.1 3103.1.1 Conformance. Temporary structures and uses shall conform to the structural strength, fire safety, means of egress, accessibil ventilation and sanitary requirements of this code as necessary to ensure public health, safety and general wel modified by this section. 201 pdf_text
3103.1.2 3103.1.2 Fire protection. Temporary structures and uses shall be protected from fire hazards in accordance with Sections 3103.1.2.1 an 201 pdf_text
3103.1.2.1 3103.1.2.1 Portable fire extinguishers. Temporary structures exceeding 600 square feet (56 m2) in floor area or where cooking will occur wit (6096 mm) of the structure shall be provided with portable fire extinguishers in accordance with Secti less than one. 201 pdf_text
3103.1.2.2 3103.1.2.2 Emergency lighting. Temporary structures exceeding 1,000 square feet (93 m2) in floor area that will be used for a period l hours shall be provided with an emergency lighting system complying with Article 700 of the Chicag Code. 201 pdf_text
3103.1.3 3103.1.3 Means of egress. 201 pdf_text
3103.1.4 3103.1.4 Structural requirements. Temporary structures shall not be required to be designed for seismic forces. Temporary structures installed f less shall be designed to withstand at least 56 percent of the wind loads applicable to permanent structures. T structures installed for more than 6 weeks shall be designed to withstand at least 64 percent of the wind loads permanent structures. Temporary structures shall be allowed to be designed for reduced environmental forces loads and ice loads, based on limited seasonal exposure. Where temporary structures do not meet all structur applicable to permanent structures, the building official may issue a conditional permit requiring monitoring conditions and allowing the structure to be used up to a specified wind velocity or under other applicable cli limitations. 202 pdf_text
3103.1.5 3103.1.5 Sanitary requirements. Temporary structures and uses shall be provided with temporary sanitary facilities in accordance with the pro Chicago Plumbing Code. 202 pdf_text
3103.1.6 3103.1.6 Electrical equipment and wiring. Electrical equipment and wiring shall comply with the Chicago Electrical Code. 202 pdf_text
3103.2 3103.2 Temporary tents and membrane structures. Temporary tents and other membrane structures shall comply with Sections 3103.2.1 through 3103.2.4. 202 pdf_text
3103.2.1 3103.2.1 Location. Temporary tents and membrane structures shall not be erected within 12 feet (3658 mm) of existing buildings lines. Exceptions: 202 pdf_text
3103.2.2 3103.2.2 Flame propagation. The permit application shall be accompanied by a certificate of fire resistance executed by an approved agen that the structure meets the flame propagation performance requirements of NFPA 701. If the treatment indic certificate is not of the permanent type, the certificate shall be dated within 360 days preceding the last date o If the tent fabric is certified as having been rendered permanently fire resistant during manufacture, or is mad inherently fire resistant fabric, then the certificate shall be dated no earlier than seven years prior to the last d use. The certificate shall indicate the type of fabric and method of compliance with NFPA 701. 202 pdf_text
3103.2.2.1 3103.2.2.1 Label. Membrane structures and their components shall have a permanently affixed label bearing the identifi and fabric or material type. 202 pdf_text
3103.2.3 3103.2.3 Certification. The permit application shall be accompanied by a certificate providing all of the following information relati propagation performance criteria of the fabric: 202 pdf_text
3103.2.4 3103.2.4 Liquefied petroleum gas (LP gas). Liquefied petroleum gas (LP gas) tanks shall not be permitted inside of or within 10 feet (3048 mm) of tempo membrane structures. 202 pdf_text
3103.2.5 3103.2.5 Air-supported and air-inflated structures. Temporary air-supported structures and air-inflated structures shall comply with Sections 3103.2.5.1 throug 203 pdf_text
3103.2.5.1 3103.2.5.1 Design. The design and construction of the fabric envelope and the method of anchoring shall be in accordanc Architectural Fabric Structures Institute FSAAS. 203 pdf_text
3103.2.5.2 3103.2.5.2 Blowers. An air-supported structure containing occupiable space shall be furnished with not less than two blo which has adequate capacity to maintain full inflation pressure with normal leakage. The design of the be so as to provide integral limiting pressure at the design pressure specified by the manufacturer. 203 pdf_text
3103.2.5.3 3103.2.5.3 Inflation system. Temporary structures with an occupant load greater than 100 shall also comply with Section 3102.8. 203 pdf_text
3103.3 3103.3 Temporary structures other than tents and membrane structures. Temporary structures, other than tents and other membrane structures, shall comply with Sections 3103.3.1 and 310 203 pdf_text
3103.3.1 3103.3.1 Location. Temporary structures of combustible construction shall not be erected within 12 feet (3658 mm) of existing b property lines. Exceptions: 203 pdf_text
3103.3.2 3103.3.2 Liquefied petroleum gas (LP gas). Liquefied petroleum gas (LP gas) tanks shall not be permitted inside of or within 10 feet (3048 mm) of tempo of combustible construction." (Amend Coun. J. 7-24-19, p. 3646, § 34; Amend Coun. J. 2-19-20, p. 14473, Art. II, § 94; Amend Coun. J. 6-25-21, p. 3218 203 pdf_text
3114.1 3114.1 General. Fences shall comply with the provisions of Sections 3114.2 through 3114.4. 204 pdf_text
3114.2 3114.2 Classification. Fences shall be classified according to the general form of their construction as screen fences or solid fences and acco combustibility in accordance with Sections 3114.2.1 through 3114.2.3. 204 pdf_text
3114.2.1 3114.2.1 Screen fences. A screen fence is a fence so constructed that at least 50 percent of the superficial area thereof consists of regu distributed apertures. 204 pdf_text
3114.2.2 3114.2.2 Solid fences. A solid fence is a fence so constructed that less than 50 percent of the superficial area thereof consists of regu distributed apertures. 204 pdf_text
3114.2.3 3114.2.3 Combustible fences. Any fence not constructed entirely of noncombustible materials shall be classed as a combustible fence. 204 pdf_text
3114.4 3114.4 Wind load. Fences shall be designed and constructed to resist a horizontal wind pressure of not less than 30 pounds per square fo kN/m2) in addition to all other forces to which they may be subjected. 205 pdf_text
3114.5 3114.5 Barbed wire and razor wire. The use of barbed wire or razor wire at a height less than 8 feet (2438 mm) above the ground shall be prohibited. Exception: Where wholly located on or over private property, the use of barbed wire or razor wire more than mm) above the ground shall be allowed." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 97) CHAPTER 14B-32 ENCROACHMENTS INTO THE PUBLIC WAY 205 pdf_text
32 32,000 N SM UL UL 42 pdf_text
32 32. Delete Section 907.2.12.3. 77 pdf_text
32 32. Revise Section 1705.14.6.3 to read: "1705.14.6.3 Primer, paint and encapsulant bond tests. Bond tests to qualify a primer, paint or encapsulant shall be conducted where the sprayed fire-resistant material is ap primed, painted or encapsulated surface for which acceptable bond-strength performance between these coatings and fire-resistant material has not been determined. A bonding agent approved by the sprayed fire-resistant material ma shall be applied to a primed, painted or encapsulated surface where the bond strengths are found to be less than requi 161 pdf_text
32 32. Revise Section 903.3.1.2 to read: "903.3.1.2 NFPA 13R sprinkler systems. Automatic sprinkler systems installed in Group R-5; Group R-3; and Group R-4, Condition 1 shall be permitted to be throughout in accordance with NFPA 13D, provided the building shall not exceed 45 feet (13.7 m) in building height 70 pdf_text
32 32. Revise exception 3 to Section 1810.3.9 to read: "3. For Group R-3, R-5 and U occupancies not exceeding two stories of light-frame construction, reinforce permitted to be placed after concreting, while the concrete is still in a semifluid state, and the concrete cover r permitted to be reduced to 2 inches (51 mm), provided that the construction method can be demonstrated to t of the building official." 174 pdf_text
32 32. Revise the definition of "building area" to read: "BUILDING AREA. The value determined in accordance with Section 203.4." 5 pdf_text
3202.1.1.2 3202.1.1.2 Centerline of public way. Except as provided in Section 3202.1.1.4, in no case shall foundations extend within five feet (1524 mm) of the cent public way. 206 pdf_text
3202.1.1.3 3202.1.1.3 No usable floor area. Except where sub-sidewalk space is permitted, no foundation, or any part thereof, shall project into a public way in s to add to the floor area of any building or structure. 206 pdf_text
3202.1.1.4 3202.1.1.4 Deep foundations. Portions of foundations, constructed lower than 20 feet (6096 mm) below city datum, may project into a public way s as the building official may approve as necessary for the stability of the building or structure of which they are a part 206 pdf_text
3202.3.1 3202.3.1 Awnings, canopies, marquees and signs. Awnings, canopies, marquees and signs shall be constructed so as to support applicable loads as specified in Awnings, canopies, marquees and signs shall comply with Chapters 10-24 and 10-28 of the Municipal Code. 206 pdf_text
3202.3.2 3202.3.2 Cornices, belt courses and similar projections. Where the vertical clearance above grade to projecting cornices, rustications, quoins, moldings, belt courses, oriel windows, pediments and similar projections of a decorative character is more than 12 feet (3658 mm), t encroachment shall be 2 feet (610 mm) and shall not exceed 5 percent of the wall area. 206 pdf_text
3202.3.3 3202.3.3 Fire escapes. Fire escapes hereafter erected shall not project over a public way except when erected to replace an existing r escape which projects over the public way. 206 pdf_text
3202.3.4 3202.3.4 Pedestrian walkways. The installation of a pedestrian walkway over a public way shall be subject to Chapter 10-28 of the Municipal 206 pdf_text
32180 32180, Art. II, § 14; Amend Coun. J. 12-14-22, p. 58278, Art. III, § 2) 78 pdf_text
33 33. Revise Section 1810.3.9.4 to read: "1810.3.9.4 Seismic reinforcement. Where a structure is assigned to Seismic Design Category C, reinforcement shall be provided in accordance with Sec 174 pdf_text
33 33. Delete Section 903.3.1.2.1. 70 pdf_text
33 33. Revise Section 1705.15 to read: "1705.15 Mastic and intumescent fire-resistant coatings. Special inspections and tests for mastic fire-resistant coatings and intumescent fire-resistant coatings applied to stru and decks shall be performed in accordance with AWCI 12-B. Special inspections and tests shall be based on the per construction documents and manufacturer’s instructions." 161 pdf_text
33 33. Delete Section 907.2.13. 77 pdf_text
33 33. Revise the definition of "building height" to read: "BUILDING HEIGHT. The value determined in accordance with Section 203.3." 5 pdf_text
3308.4 3308.4 Damage. Costs and expenses incurred by the City to repair damage to the public way or city sewer system caused by construct or rehabilitation work on adjacent private property shall be reimbursed in accordance with Section 7-28-395 of the M Code." (Amend Coun. J. 10-7-20, p. 21791, Art. II, § 33) 210 pdf_text
3314.1 3314.1 Program development and maintenance. The owner or owner’s authorized agent shall be responsible for the development, implementation and maintenance o plan establishing a fire prevention program at the project site applicable throughout all phases of the construction, re or demolition work. The plan shall address the requirements of this chapter and other applicable portions of this code staff, and staff training requirements. The plan shall be made available for review by the building official or fire code request. 210 pdf_text
3314.2 3314.2 Program superintendent. The owner shall designate a person to be the fire prevention program superintendent who shall be responsible for the 210 pdf_text
3314.3 3314.3 Prefire plans. The fire prevention program superintendent shall develop and maintain a prefire plan in cooperation with the fire cod fire code official shall be notified of changes affecting the utilization of information contained in such prefire plans. 211 pdf_text
3314.4 3314.4 Training. Training of responsible personnel in the use of fire protection equipment shall be the responsibility of the fire preven superintendent. Records of training shall be kept and made a part of the written plan for the fire prevention program. 211 pdf_text
3314.5 3314.5 Fire protection devices. The fire prevention program superintendent shall determine that all fire protection equipment is maintained and servi accordance with this code. Fire protection equipment shall be inspected in accordance with the fire protection progra 211 pdf_text
3314.6 3314.6 Hot work operations. The fire prevention program superintendent shall be responsible for supervising the permit system for hot work oper accordance with the Chicago Fire Prevention Code. 211 pdf_text
3314.7 3314.7 Impairment of fire protection systems. Impairments to any fire protection system in an existing building shall be in accordance with the Chicago Fire Preve 211 pdf_text
3314.7.1 3314.7.1 Smoke detectors and smoke alarms. Smoke detectors and smoke alarms located in an area where airborne construction dust is expected shall be c prevent exposure to dust or shall be temporarily removed. Smoke detectors and alarms that were removed sha upon conclusion of dust-producing work. Smoke detectors and smoke alarms that were covered shall be insp cleaned, as necessary, upon conclusion of dust-producing work. 211 pdf_text
3314.8 3314.8 Temporary covering of fire protection devices. Coverings placed on or over fire protection devices to protect them from damage during construction processes shall immediately removed upon the completion of the construction processes in the room or area in which the devices are 211 pdf_text
3315.1 3315.1 Listed. Temporary heating devices shall be listed and labeled. The installation, maintenance and use of temporary heating d in accordance with the listing and the manufacturer’s instructions. 211 pdf_text
3315.2 3315.2 Oil-fired heaters. Oil-fired heaters shall comply with the Chicago Fire Prevention Code. 211 pdf_text
3315.3 3315.3 LP-gas heaters. Fuel supplies for liquefied-petroleum gas-fired heaters shall comply with the Chicago Fire Prevention Code and Chi Code. 211 pdf_text
3315.4 3315.4 Refueling. Refueling operations for liquid-fueled equipment or appliances shall be conducted in accordance with the Chicago F Code. The equipment or appliance shall be allowed to cool prior to refueling. 211 pdf_text
3315.5 3315.5 Installation. Clearance to combustibles from temporary heating devices shall be maintained in accordance with the labeled equip operation, temporary heating devices shall be fixed in place and protected from damage, dislodgement or overturnin with the manufacturer’s instructions. 211 pdf_text
3315.6 3315.6 Supervision. The use of temporary heating devices shall be supervised and maintained only by competent personnel." 211 pdf_text
3316.1 3316.1 Smoking. Smoking shall be prohibited except in designated areas. "No smoking" signs shall be posted in conspicuous locations areas where smoking is permitted, noncombustible ashtrays shall be provided. 212 pdf_text
3316.2 3316.2 Combustible debris, rubbish and waste. Combustible debris, rubbish and waste material shall comply with the requirements of Sections 3316.2.1 through 33 212 pdf_text
3316.2.1 3316.2.1 Combustible waste material accumulation. Combustible debris, rubbish and waste material shall not be accumulated within buildings. 212 pdf_text
3316.2.2 3316.2.2 Combustible waste material removal. Combustible debris, rubbish and waste material shall be removed from buildings at the end of each shift of w 212 pdf_text
3316.2.3 3316.2.3 Rubbish containers. Where rubbish containers with a capacity exceeding 5.33 cubic feet (40 gallons) (0.15 m 3) are used for temp of combustible debris, rubbish and waste material, they shall have tight-fitting or self- closing lids. Such rubb shall be constructed entirely of materials that comply with either of the following: 212 pdf_text
3316.2.4 3316.2.4 Spontaneous ignition. Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in a listed disposal container. 212 pdf_text
3316.3 3316.3 Burning of combustible debris, rubbish and waste. Combustible debris, rubbish and waste material shall not be disposed of by burning on the site. 212 pdf_text
3316.4 3316.4 Open burning. Open burning shall comply with the Chicago Fire Prevention Code. 212 pdf_text
3316.5 3316.5 Fire watch. Where required by the fire code official or the prefire plan established in accordance with Section 3314.3, a fire watc provided for demolition and construction work that is unusually hazardous in nature, such as temporary heating or h 212 pdf_text
3316.5.1 3316.5.1 Fire watch during construction. Where required by the fire code official, a fire watch shall be provided during nonworking hours for new con exceeds 40 feet (12.2 m) in height above the lowest adjacent grade. 212 pdf_text
3316.5.2 3316.5.2 Fire watch personnel. Trained personnel shall be provided to serve as an on-site fire watch. Fire watch personnel shall be provided than one means for notification of the fire department, and the sole duty of such personnel shall be to perform patrols and watch for the occurrence of fire. The combination of fire watch duties and site security duties is a watch personnel shall be trained in the use of portable fire extinguishers. 212 pdf_text
3316.5.3 3316.5.3 Fire watch location and records. The fire watch shall include areas specified by the prefire plan established in accordance with Section 3314.3 watch personnel shall keep a record of all time periods of duty, including a log entry each time the site was p each time a structure under construction was entered and inspected. The records and log entries shall be mad review by the fire code official upon request. 212 pdf_text
3316.6 3316.6 Cutting and welding. Welding, cutting, open torches and other hot work operations and equipment shall comply with the Chicago Fire Pre 212 pdf_text
3316.7 3316.7 Electrical. Temporary wiring for electrical power and lighting installations used in connection with the construction, alteration of buildings, structures, equipment or similar activities shall comply with the Chicago Electrical Code. 212 pdf_text
3316.8 3316.8 Cooking. Cooking shall be prohibited except in designated cooking areas. Signs with a minimum letter height of 3 inches (76 minimum brush stroke of 1/2 inch (13 mm) shall be posted in conspicuous locations in designated cooking areas and DESIGNATED COOKING AREA. 212 pdf_text
3317.1 3317.1 Storage of flammable and combustible liquids. Storage of flammable and combustible liquids shall be in accordance with the Chicago Fire Prevention Code. 213 pdf_text
3317.2 3317.2 Class I and Class II liquids. The storage, use and handling of flammable and combustible liquids at construction sites shall be in accordance with Fire Prevention Code. Ventilation shall be provided for operations involving the application of materials containing f solvents. 213 pdf_text
3317.3 3317.3 Housekeeping. Flammable and combustible liquid storage areas shall be maintained clear of combustible vegetation and waste mate storage areas shall not be used for the storage of combustible materials. 213 pdf_text
3317.4 3317.4 Precautions against fire. Sources of ignition and smoking shall be prohibited in flammable and combustible liquid storage areas. Signs shall b accordance with the Chicago Fire Prevention Code. 213 pdf_text
3317.5 3317.5 Handling at point of final use. Class I and II liquids shall be kept in appropriate safety containers. 213 pdf_text
3317.6 3317.6 Leakage and spills. Leaking vessels shall be immediately repaired or taken out of service and spills shall be cleaned up and disposed of p 213 pdf_text
3318.1 3318.1 Storage and handling. The storage, use and handling of flammable gases shall comply with the Chicago Fire Prevention Code. 213 pdf_text
3318.2 3318.2 Cleaning with flammable gas. Flammable gases shall not be used to clean or remove debris from piping open to the atmosphere. 213 pdf_text
3318.2.1 3318.2.1 Pipe cleaning and purging. The cleaning and purging of flammable gas piping systems, including cleaning new or existing piping system piping systems into service and purging piping systems out of service, shall comply with NFPA 56. Exceptions: 213 pdf_text
3319.1 3319.1 Storage and handling. Explosive materials shall be stored, used and handled in accordance with the Chicago Fire Prevention Code. 213 pdf_text
3319.2 3319.2 Supervision. Blasting operations shall be conducted in accordance with the Chicago Fire Prevention Code. 213 pdf_text
3319.3 3319.3 Demolition using explosives. Fire hoses for use by demolition personnel shall be maintained at the demolition site wherever explosives are used fo Such fire hoses shall be connected to a water supply and shall be capable of being brought to bear on post-detonation anywhere on the site of the demolition operation." 214 pdf_text
3320.1 3320.1 Emergency telephone. Emergency telephone facilities with ready access shall be provided at the construction site, or an equivalent means o communication shall be provided. The street address of the construction site and the emergency telephone number of department shall be posted adjacent to the telephone. Alternatively, where an equivalent means of communication is address and fire department emergency telephone number shall be posted at the main entrance to the site, in guard sh construction site office." 214 pdf_text
3321.1 3321.1 Conditions of use. Internal-combustion-powered construction equipment shall be used in accordance with all of the following condition 214 pdf_text
3322.1 3322.1 General. Roofing operations utilizing heat-producing systems or other ignition sources shall be conducted in accordance with Fire Prevention Code. 214 pdf_text
3322.2 3322.2 Asphalt and tar kettles. Asphalt and tar kettles shall be operated in accordance with the Chicago Fire Prevention Code. 214 pdf_text
3322.3 3322.3 Fire extinguishers for roofing operations. Fire extinguishers shall comply with the Chicago Fire Prevention Code. There shall be not less than one multiple-pu fire extinguisher with a minimum 3-A 40-B:C rating on the roof being covered or repaired." 214 pdf_text
3323.1 3323.1 Construction. Scaffolding shall be constructed and installed to protect the safety of persons working on, passing under or passing b scaffolding. 214 pdf_text
3323.2 3323.2 Material. When the extent or location of scaffolding is such as to create an unusual fire hazard, the fire code official is authoriz the use of noncombustible material or fire-retardant treated wood. 214 pdf_text
3323.3 3323.3 Safeguards. Scaffolding shall be constructed, operated, maintained and disassembled in a manner that follows accepted engineeri the manufacturer’s specifications. ASSE A10.8 and ASME A120.1 shall be considered as accepted engineering pract 214 pdf_text
3323.3.1 3323.3.1 Not in use. When scaffolding is, or is expected to be, unoccupied for more than two hours, such scaffolding shall be safel attached to the building in accordance with federal regulations, ASSE standards and the manufacturer’s speci 215 pdf_text
3323.3.2 3323.3.2 Wind. When wind conditions actually do, or are predicted or expected to, or based on other measurements can reaso extrapolated to, exceed a velocity at the scaffold level identified in the manufacturer’s specifications as posin such scaffolding shall be lowered to the ground and secured or, if required by the manufacturers’ specificatio the roof and secured." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 101) 215 pdf_text
3324.1 3324.1 General. Work sites shall be maintained in accordance with Sections 3324.2 through 3324.5 during construction, demolition, e rehabilitation activities. Exception: The provisions of this section do not apply to activities conducted within a completely enclosed s 215 pdf_text
3324.2 3324.2 Fencing. Work sites shall be enclosed and secured by a continuous fence at least 6 feet (1829 mm) in height which shall be an wind loads of 30 pounds per square foot (1436 Pa) without deflection of more than 3 inches (76.2 mm) between the t of the fence. The fence, including gates, shall be covered for its full height and length in fabric mesh that will allow t air but contain dust and dirt. The owner and general contractor shall be responsible for keeping the fence and fabric repair and free of graffiti and unauthorized advertising. 215 pdf_text
3324.2.1 3324.2.1 Gate. One gate, no larger than is reasonably necessary to allow truck access, may remain open when workers are ac working on the site. 215 pdf_text
3324.3 3324.3 Storage. All construction materials, dumpsters and debris collection devices shall be kept within the required fence unless a p of the public way has been obtained from the Commissioner of Transportation. Dumpsters shall be regularly serviced contents from extending past the top of the dumpster. Construction materials and waste shall be gathered at the end o day and stored or disposed of in a neat and orderly manner. Where materials are stored for use on floors above grade, secured to prevent loosening or dispersion due to weather conditions or other phenomena. 215 pdf_text
3324.4 3324.4 Litter and garbage. Sealed containers for litter and garbage shall be provided throughout the work site. At least one container shall be pr every floor and every 4,000 square feet (372 m 2 ) of work area. All litter and garbage must be removed from the wo 215 pdf_text
3324.5 3324.5 Dust control. The general contractor shall employ adequate wetting or other abatement measures to prevent the off-site dispersion debris from the work site. The general contractor shall take necessary steps to minimize the amount of dirt and debri transmitted by construction vehicles, including but not limited to stoning or paving of haul roads, wheel wash station sweepers. All construction and demolition debris shall be removed from upper floors using dust-tight chutes or lower containers. Construction and demolition debris shall not be dropped or thrown from any floor. Where work occurs o four or more stories above grade plane, the work area shall be enclosed with fabric mesh as provided in Section 332 215 pdf_text
3324.5.1 3324.5.1 Masonry work. For masonry work, the immediate work area shall be enclosed to contain dust and debris from grinding or cut operations. (Amend Coun. J. 2-19-20, p. 14473, Art. II, 102) CHAPTER 14B-34 RESERVED 215 pdf_text
34 34. Delete the definition of "building line." 5 pdf_text
34 34. Revise Section 907.2.14 by deleting "Section 3206.5 of." 77 pdf_text
34 34. Revise the title and first sentence of Section 1810.3.9.4.2 to read: "1810.3.9.4.2 Seismic reinforcement in Seismic Design Category D. For structures assigned to Seismic Design Category D, cast-in-place deep foundation elements shall be reinforced as this section. Reinforcement shall be provided where required by analysis." 174 pdf_text
34 34. Delete item 3 (and subitems) in Section 903.3.1.2.3. 70 pdf_text
34 34. Delete Section 1705.16 and its subsections. 161 pdf_text
35 35. Revise Section 1705.18 to read: "1705.18 Testing for smoke control. Smoke control systems shall be tested by a special inspector prior to acceptance testing by or in the presence of the fi official." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 78) 161 pdf_text
35 35 inches (1220 mm) maximum above the finish floor or ground." 109 pdf_text
35 35. Revise Section 903.3.1.3 to read: "903.3.1.3 NFPA 13D sprinkler systems. Automatic sprinkler systems installed in Group R-5; Group R-3; Group R-4, Condition 1; and townhouses shall be pe installed throughout in accordance with NFPA 13D, provided the building shall not exceed 45 feet (13.7 m) in buildi 70 pdf_text
35 35. Revise Section 907.2.15 by replacing "an approved" with "a." 77 pdf_text
35 35. Revise the definition of "building official" to read: "BUILDING OFFICIAL. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions." 5 pdf_text
35 35. Revise Section 1810.3.9.5 to read: "1810.3.9.5 Belled drilled shafts. 174 pdf_text
36 36. Revise Section 1810.3.9.6 to read: "1810.3.9.6 Socketed drilled shafts. Socketed drilled shafts shall have a permanent pipe or tube casing that extends down to bedrock and an uncased sock the bedrock, both filled with concrete. Socketed drilled shafts shall have reinforcement or a structural steel core for t indicated by accepted engineering analysis. The depth of the rock socket shall be sufficient to develop the full load-bearing capacity of the element with a minim factor in accordance with Section 1810.3.3.1.7, but the depth shall be not less than one foot (305 mm)." 175 pdf_text
36 36,000 NP NP NP NP 42 pdf_text
36 36. Revise Section 907.2.18 to read: "907.2.18 Deep underground buildings. Where the lowest occupiable space is more than 60 feet (18 288 mm) below the finished floor of the lowest level of the structure shall be equipped throughout with a manual fire alarm system." 77 pdf_text
36 36. Revise the last sentence of Section 903.3.5 to read: "For connections to the public waterworks systems, the water supply test used for design of fire protection systems s acceptable to the fire code official and not less than one year old." 70 pdf_text
36 36. Insert the following definition: "BUILT ENVIRONMENT (for Chapter 11). Those parts of the physical environment which are designed, constru by people, including all public facilities and multi-story housing." 5 pdf_text
37 37. Delete Section 907.2.19. 77 pdf_text
37 37. Revise Section 1810.3.10.2 to read: "1810.3.10.2 Materials. Reinforcement shall consist of deformed reinforcing bars in accordance with ASTM A615 Grade 60, 75 or 80 or AS Grade 150. The steel pipe or tube shall have a minimum wall thickness of 1/4 inch (6.3 mm). Splices shall comply with Section steel pipe or tube shall have a minimum yield strength of 45,000 psi (310 MPa) and a minimum elongation of 15 per by mill certifications or two coupon test samples per 40,000 pounds (18 160 kg) of pipe or tube." 175 pdf_text
37 37. Revise Section 903.3.8.4 by deleting "approved." 70 pdf_text
37 37. Revise the definition of "capacitor energy storage system" to read: "CAPACITOR ENERGY STORAGE SYSTEM. As defined in Chapter 2 of the Chicago Fire Prevention Code." 5 pdf_text
37.1 37.1 Insert a new Section 903.3.9 to read: "903.3.9 Concealed sprinkler heads. Where concealed sprinkler heads are used, cover plates shall have a brass, chrome or other unpainted metallic finish. 70 pdf_text
38 38. Delete Section 907.2.20. 77 pdf_text
38 38. Insert the following definition: "CARPORT. A structure or portion of a structure that is open on at least two sides and in which not more than five used by the occupants of the building or buildings on the premises are stored or kept." 5 pdf_text
38 38. Revise Section 1810.3.10.4 to replace "Seismic Design Category D, E or F" with "Seismic Design Category D." 175 pdf_text
38 38. Revise exception 1 to Section 903.4 by replacing "one- and two-family dwellings" with "Group R-5 occupancie 70 pdf_text
39 39. Revise the title and first sentence of Section 1810.3.11.1 to read: "1810.3.11.1 Seismic Design Categories C and D. For structures assigned to Seismic Design Category C or D, concrete deep foundation elements shall be connected to by embedding the element reinforcement or field-placed dowels anchored in the element into the pile cap for a distan their development length in accordance with ACI 318." 175 pdf_text
39 39. Revise the definition of "ceiling limit" to read: "CEILING LIMIT. As defined in Chapter 2 of the Chicago Fire Prevention Code." 5 pdf_text
39 39. Revise the exceptions to Section 907.3.1 to read: "Exception: In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall visible and an audible signal in a prominent location. Smoke detector trouble conditions shall activate a visible or au a prominent location and shall be identified as air duct detector trouble." 77 pdf_text
39 39. Revise Section 903.4 by adding a sentence, following the exceptions, to read: "All valves in supply pipes to automatic sprinkler systems shall be secured open." 71 pdf_text
4 4 Not Permitted 61 pdf_text
4 4. The opposite side of a court. Where the value of W is greater than 30 feet (9144 mm), a value of 30 feet (9144 mm) shall be used in calculating th 43 pdf_text
4 4. Delete Table 906.1. 73 pdf_text
4 4. Tubing shall be neatly tied and supported within the enclosure. Tubing bridging ca doors or moveable devices shall be of sufficient length to avoid tension and excessive shall be protected against abrasion. Tubing connected to devices on doors shall be fast hinges. S101.13.2 Isolation from other functions. Control tubing serving other than smoke control functions shall be isolated by automatic isolation valves or s independent system. S101.13.3 Testing. Control air tubing shall be tested at three times the operating pressure for not less than 30 minutes without an loss in gauge pressure prior to final connection to devices. S101.14 Marking and identification. The detection and control systems shall be clearly marked at all junctions, accesses and terminations. S101.15 Control diagrams. Identical control diagrams showing all devices in the system and identifying their location and function shall be main 225 pdf_text
4 4. From a technical production area in accordance with Section 410.5 ." 97 pdf_text
4 4. Elevator car lighting. 27 pdf_text
4 4. At the uppermost ceiling of each interior exit stairway." 75 pdf_text
4 4. Revise Section 910.2.2 to read: "910.2.2 High-piled combustible storage. A mechanical smoke removal system installed in accordance with Section 910.4 shall be installed in buildings and p containing high-piled combustible storage." 79 pdf_text
4 4. The minimum positive pressure of 0.10 inch of water (25 Pa) and a maximum positive pre inch of water (67 Pa) with respect to occupied floors are not required at the floor of recall with open. S101.21.1.1 Use of ventilation systems. Ventilation systems, other than hoistway supply air systems, are permitted to be used to exhaust air fr spaces on the fire floor, two floors immediately below and one floor immediately above the fire floor building’s exterior where necessary to maintain positive pressure relationships as required in Section during operation of the elevator shaft pressurization system. S101.21.2 Rational analysis. A rational analysis complying with Section S101.4 shall be submitted with the construction documents. S101.21.3 Ducts for system. Any duct system that is part of the pressurization system shall be protected with the same fire-resistance rati for the elevator shaft enclosure. S101.21.4 Fan system. The fan system provided for the pressurization system shall be as required by Sections S101.21.4.1 through S S101.21.4.1 Fire resistance. Where located within the building, the fan system that provides the pressurization shall be protected fire-resistance rating required for the elevator shaft enclosure. S101.21.4.2 Smoke detection. The fan system shall be equipped with a smoke detector that will automatically shut down the fan syst smoke is detected within the system. S101.21.4.3 Separate systems. A separate fan system shall be used for each elevator hois 230 pdf_text
4 4. Fans, dampers and other operating equipment in a fault status – YELLOW/AMBER. S101.16.2 Smoke control panel. The fire fighter’s control panel shall provide control capability over the complete smoke control system equip the building as follows: 226 pdf_text
4 4. Revise Table 707.3.10 by deleting "FIRE WALLS" from the title. 58 pdf_text
4 4. Revise Section 1011.4 to read: "1011.4 Walkline. Where a stair includes winder treads, the walkline shall comply with Section 1011.4.1 or 1011.4.2. 95 pdf_text
4 4. Revise Section 1404.3 by replacing "an approved design" with "a design." 129 pdf_text
4 4. Ambulatory care facilities and Group I-2 occupancies shall be ventilated by mechanical m accordance with the Chicago Mechanical Code. 120 pdf_text
4 4. Revise Section 717.5.1 to read: "717.5.1 Fire walls. Ducts and air transfer openings permitted in fire walls in accordance with Section 706.11 shall be protected with liste fire dampers installed on both sides of the fire wall in accordance with their listing." 62 pdf_text
4 4. Revise Section 2606.7.4 to read: "2606.7.4 Fire suppression system. In buildings that are equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, l systems shall be protected both above and below unless the automatic sprinkler system has been approved for installa above the light-diffusing system. Areas of light-diffusing systems that are protected in accordance with this section sh limited." 194 pdf_text
4 4. The contractor is permitted to employ the special inspection agencies." 155 pdf_text
4 4. Replace Table 1006.2.1 as shown: TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY For SI: 1 foot = 304.8 mm, 1 square foot = 0.0929 m 2. NP = Not permitted. a. Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. b. Group H occupancies equipped throughout with an automatic sprinkler system in accordance with Section 903.2.5. c. For a room or space used for assembly purposes having fixed seating, see Section 1029.8. d. For the travel distance limitations in Group I-2, see Section 407.4. e. The common path of egress travel distance and occupant load limitations shall not apply to a building exclusively containing a single dwelling unit an occupancy or within a townhouse. f. The common path of egress travel distance in a Group S-2 parking garage shall be not more than 100 feet. g. For the travel distance limitations in Groups R-3, R-4 and R-5 equipped throughout with an automatic sprinkler system in accordance with Section 90 88 pdf_text
4 4. In areas that are not open to the public within occupancies in Group I-3, F, H, M or S; for alternat devices and ship's ladders; and in similar locations where children under the age of 5 are unlikely to b are approved by the building official, guards shall not have openings that allow passage of a sphere 2 mm) in diameter. 100 pdf_text
4 4. Delete Section 1103.2.8. 110 pdf_text
4 4. Revise Section 911.1.4 to read: "911.1.4 Layout review. A layout of the fire command center and all features required by this section to be contained therein shall be submitt code official for review and acceptance prior to installation." 80 pdf_text
4 4. Revise Section 2303.1.5 to read: "2303.1.5 Wood structural panels. Wood structural panels, where used structurally (including those used for siding, roof and wall sheathing, subfloorin and built-up members), shall conform to the requirements for their type in DOC PS 1, DOC PS 2 or ANSI/APA PRP panel or member shall be identified for grade, bond classification, and Performance Category by the trademarks of a agency. The Performance Category value shall be used as the "nominal panel thickness" or "panel thickness" whene in this code. Wood structural panel components shall be designed and fabricated in accordance with the applicable st in Section 2306.1 and identified by the trademarks of an approved agency indicating conformance to the applicable s addition, wood structural panels where permanently exposed in outdoor applications shall be of exterior type, except structural panel roof sheathing exposed to the outdoors on the underside is permitted to be Exposure 1 type." 183 pdf_text
4 4. Agricultural and industrial storage structures intended only for incidental human occupancy. 152 pdf_text
4 4. Where fire separation distance is based on an imaginary line between buildings on the same lot, the maxi protected and unprotected exterior wall openings shall not be limited for stories that are at least 50 feet (15.2 above the roof of adjacent buildings on the same lot." 56 pdf_text
4 4. Revise Section 1408.10.2 by replacing "an approved" with "a." 133 pdf_text
4 4. Name of person or firm treating the material. 202 pdf_text
4 4. Revise Section 2308.2.6 by deleting "assigned to Seismic Design Category B, C, D or F." 185 pdf_text
4 4. The failure load corresponding to a settlement of 0.2 √D + PL/AE where D = the diameter or diagonal dimension in inches, P = Load, L = Length, A = Area, E = Modul Elasticity. 172 pdf_text
4 4. Revise Section 1803.4 by replacing "registered design professional" with "registered geotechnical engineer." 163 pdf_text
4 4. Revise Section 1005.6 by replacing "two adjacent stories" with "stories immediately above and below." 87 pdf_text
4 4. Revise Section 404.7 to read: "404.7 Standby power. Equipment required to provide smoke control shall be provided with standby power." 27 pdf_text
4 4. Lofts in accordance with Section 1207.5. 125 pdf_text
4 4. Revise Section 308.3.1.1 to read: "308.3.1.1 Condition 1. This occupancy condition shall include facilities that provide nursing or medical care but do not provide emergency obstetrics or in-patient stabilization units for psychiatric or detoxification purposes, including but not limited to nursi foster care facilities." 21 pdf_text
4 4. Revise the exception to Section 904.12 by deleting "Section 304.1 of." 71 pdf_text
4 4. Revise item 5.1.3 in Section 1202.3 to read: "5.1.3. Where both air-impermeable insulation and air-permeable insulation are provided, the air- imperme shall be applied in direct contact with the underside of the structural roof sheathing in accordance with Item 5 be in accordance with the R-values in Table 1202.3 for condensation control. The air-permeable insulation sh 120 pdf_text
4 4. Installation and anchorage of ductwork designed to carry hazardous materials in structures Seismic Design Category C or D. 160 pdf_text
4 4. Revise the exceptions to Section 1106.6 to read: "Exceptions: 112 pdf_text
4 4. Low-hazard special industrial occupancies in accordance with Section 503.1.1. 76 pdf_text
4 4. Rooftop access penthouses and other rooftop structures associated with occupiable rooftop considered in determining building height in accordance with Section 1513. 17 pdf_text
4 4. Revise Sections 1008.3.1, 1008.3.2, and 1008.3.3 by replacing "power supply failure" with "normal power suppl 92 pdf_text
4 4. Expansion index greater than 20, determined in accordance with ASTM D4829. Steel slag shall be tested for expansive properties in accordance with ASTM D4792 prior to use as a fill material." 163 pdf_text
4 4. Revise exception 3 to Section 714.4.2 by replacing "any size or type" with "any size or type allowed by the Chic Code." 60 pdf_text
4 4. Sleeping units of Group I occupancies." 92 pdf_text
4 4. Recommended installation procedures. 163 pdf_text
4 4. Add a new Section 1109.7.1 to read: "1109.7.1 Limited use/limited application elevators. Limited use/limited application elevators shall be allowed for the following applications: 118 pdf_text
4 4. Revise Section 704.12 by deleting "approved." 52 pdf_text
4 4. Revise Section 1504.7 to read: "1504.7 Impact resistance. Roof coverings installed on low-sloped roofs in accordance with Section 1507 shall resist impact damage based on th tests conducted in accordance with ASTM D3746, ASTM D4272 or the "Resistance to Foot Traffic Test" in Section 135 pdf_text
4 4. Exit signs are not required in dayrooms, sleeping rooms or dormitories in occupancies in Group I- 98 pdf_text
4 4. Revise row 9 of Table 1607.1 by adding "including associated kitchens" in the first column. 146 pdf_text
4 4. Revise the definition of "accreditation body" to read: "ACCREDITATION BODY. A third-party organization that is independent of the grading and inspection agencies, lumber mills, and that initially accredits and subsequently monitors, on a continuing basis, the competency and perfo grading or inspection agency related to carrying out specific tasks." 4 pdf_text
4 4. Revise Section 912.3 by deleting "be approved and shall." 81 pdf_text
4 4. Delete Section 3007.4. 200 pdf_text
4 4. Designs using NAAMM FP 1001. 148 pdf_text
4 4. In other than Group R-2 housing at places of education, in Group R-2 facilities with Acces complying with Section 1107.6.2.3.1, an accessible route is not required to connect stories or where Accessible units, all common use areas serving Accessible units and all public use areas accessible route. This exception does not apply to multi-story housing. 113 pdf_text
4 4. Nonprestressed reinforcement in tension Within micropiles 171 pdf_text
4 4. Revise Section 3202.2, including its subsections, to read: "3202.2 Encroachments above grade and below 12 feet in height. Encroachments into the public way above grade and below 12 feet (3658 mm) in clear height shall be prohibited. Do windows shall not open or project into the public way." 206 pdf_text
4 4. Where two exits, exit access doorways, exit access stairways or exit access ramps are requ within a dwelling unit, they shall be arranged remote from one another so as to minimize the c being blocked by smoke or fire. 91 pdf_text
4 4. Revise the first sentence of Section 703.7 to read: "Where there is an accessible concealed floor, floor-ceiling or attic space and within mechanical and electrical rooms fire barriers, fire partitions, smoke barriers and smoke partitions or any other wall required to have protected openin penetrations shall be effectively and permanently identified with signs or stenciling in the concealed space or mecha electrical room." 51 pdf_text
4 4. Delete the exception to Section 1604.5.1. 145 pdf_text
4 4. In one-story buildings of B, F, M, or S occupancy having a building area not exceeding 3,000 square feet 73 pdf_text
4 4. Automatic fire detection systems. 26 pdf_text
4 4. Revise Section 420.4 by replacing "in accordance with" with "where required by." 34 pdf_text
4 4. Add a new Section 1105.4 to read: "1105.4 Power-operated doors. At least one accessible entrance door to the following facilities, or each door where the entrance consists of doors in a power-operated door complying with Section 1010.1.4.2: 111 pdf_text
4 4. Revise exception 2 to Section 1020.4 to read: "2. In occupancies in Groups B, E-2, F, I-1, M, R, S and U, where the building is equipped throughout with sprinkler system in accordance with Section 903.3.1.1, the length of the dead-end corridors shall not exceed mm)." 102 pdf_text
4 4. Revise Section 1808.6 to read: "1808.6 Design for expansive soils or fills. Expansive soils or fills shall be removed in accordance with Section 1808.6.3." 169 pdf_text
4 4. Revise Section 1104.4 to read: "1104.4 Multistory buildings and facilities. At least one accessible route shall connect each accessible story, mezzanine and occupiable rooftops in multilevel bu facilities. Exceptions: 110 pdf_text
4 4. Revise the exceptions to Section 505.2.3 to read: "1. In Group B, F, M and S occupancies in buildings equipped throughout with an automatic sprinkler syste accordance with Section 903.3.1.1, mezzanines or portions thereof are not required to be open to the room in mezzanines are located, provided that the occupant load of the aggregate area of the enclosed space is not gre 40 pdf_text
4 4. Revise the first sentence of the exception to Section 715.4 to read: "Voids created at the intersection of the exterior curtain wall assemblies and such floor assemblies where the vision to the finished floor level shall be allowed to be sealed with a material to prevent the interior spread of fire." 61 pdf_text
4 4. The horizontal width of the canopy shall be not greater than 15 feet (4572 mm). 218 pdf_text
4 4. Revise Sections 1908.9.1 and 1908.9.2 by replacing "an approved" with "a." CHAPTER 14B-20 ALUMINUM 177 pdf_text
4 4. Revise Section 406.2.8 to read: "406.2.8 Separation from other occupancies. Motor-vehicle-related occupancies shall be separated from other occupancies in the same building in accordance wit 28 pdf_text
4 4. Exterior wall coverings containing foam plastic insulation complying with Section 2603. 131 pdf_text
4 4. Day care centers operating between the hours of 9:00 p.m. and 6:00 a.m. Exception: Where all rooms occupied by the day care facilities and programs have a direct ex 82 pdf_text
4 4 NP NP 45 pdf_text
4 4. The loft shall be accessed by one of the following means, which shall count as the means of egress 125 pdf_text
4 4. Revise Section 722.5.2.2 by replacing "approved" with "tested." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 25) CHAPTER 14B-8 INTERIOR FINISHES 63 pdf_text
4 4. Revise Section 2407.1.3 to read: "2407.1.3 Parking garages. Glazing materials shall not be installed in guards in parking garages except for pedestrian areas not exposed to impac vehicles." 189 pdf_text
4 4. Add a new Section 3302.4 to read: "3302.4 Construction loads. Provisions shall be made to ensure that stresses due to wind loads, dead loads and loads due to material storage and c equipment imposed during the construction, alteration, repair, addition to or demolition of any structure shall not ex allowable stresses for materials as limited by the provisions of this code." 208 pdf_text
4 4. Delete the exception to Section 1023.5. 103 pdf_text
4 4. In interior exit stairways serving 4 or fewer stories in other than Group A, E, H, and I occupancies, exit d permitted to be locked from the side opposite the egress side. 95 pdf_text
4 4 F-1, S-1 – – – – – – – – – – – – N N NP NP 45 pdf_text
4 4. Revise the notes to Table 1505.1 to read: "a. Unless otherwise required due to the location of the building within a fire district in accordance with Ap b. Class C roof coverings shall be allowed on buildings of Group R-3, R-4, R-5 and Group U occupancies, minimum fire-separation distance of 6 feet measured from the leading edge of the roof. c. Buildings that are not more than two stories above grade plane and having not more than 6,000 square fe roof area and where there is a minimum 10-foot fire separation distance from the leading edge of the roof to property line on all sides of the building, shall be allowed to have roofs of fire- retardant-treated wood shingl constructed in accordance with Section 1505.6 or No. 1 cedar or redwood shakes and No. 1 shingles construc accordance with Section 1505.7." 136 pdf_text
4 4. Revise exception 4 to Section 1010.1.2 to read: "4. Doors within or serving a single dwelling unit in Groups R-2, R-3 and R-5." 93 pdf_text
4 4. Delete items 3 and 4 in Section 903.2.1.1. 67 pdf_text
4 4. Office areas exceeding 5,000 square feet (465 m2). 76 pdf_text
4 4. Revise Section 1810.2.4 by replacing "registered design professional" with "registered geotechnical engineer." 170 pdf_text
4 4. Insert Tables 1806.2(1), 1806.2(2) and 1806.2(3) to read: TABLE 1806.2(1) PRESUMPTIVE LOAD-BEARING VALUES WITHOUT FULL GEOTECHNICAL INVESTIGATION For SI: 1 pound per square foot = 0.0479 kPa, 1 pound per square foot per foot = 0.157 kPa/m. a. Coefficient to be multiplied by the dead load. b. Cohesion value to be multiplied by the contact area, as limited by Section 1806.3.2. TABLE 1806.2(2) PRESUMPTIVE VERTICAL FOUNDATION PRESSURE VALUES WITH GEOTECHNICAL INVESTIGATION 166 pdf_text
4 4. Revise Section 2113.11.1.4 to read: "2113.11.1.4 Oil-fired appliances listed for use with L-vent. Flue lining and vent systems for use in masonry chimneys with oil-fired appliances listed for use with Type L vent sh to flue lining systems complying with Section 2113.11.1 and listed chimney liners complying with UL 641 (see Sect 180 pdf_text
4 4. Revise Section 1807.1.6.2.1 by replacing "Seismic Design Categories C, D, E and F" with "Seismic Design Cate D." 168 pdf_text
4 4. Revise the first sentence of Section 306.3 to read: "Factory industrial uses that involve the fabrication or manufacturing of noncombustible materials that during finishi processing do not involve a significant fire hazard may only be classified as F-2 occupancies with the written approv code official and may include the following:" 20 pdf_text
4 4. Revise Section 1510.5 and its subsections to read: "1510.5 Towers, spires, minarets, domes and cupolas. Towers, spires, minarets, domes, cupolas, and similar features shall be of a type of construction having fire- resistan less than required for the building on top of which such feature is built. Such features greater than 85 feet (25 908 m above grade plane as measured to the highest point on such feature, and either greater than 200 square feet (18.6 m2) area or used for any purpose other than a belfry or an architectural embellishment, shall be constructed of and suppor or IIA construction. 139 pdf_text
4 4. Revise item 5 of Section 3102.8.1.2 to read: "5. Blower inlets shall be located to provide protection from air contamination. The location of inlets shall b the construction documents." 201 pdf_text
4 4. The structure has no unusual geometrical irregularity in spatial form. 149 pdf_text
4 4. A facility where any children under two years of age occupy a level other than the level of exit dis classified as a Group I-4 occupancy. 20 pdf_text
4 4. Revise Section 1502.4 to read: "1502.4 Gutters. Gutters and leaders placed on the exterior of buildings shall be of noncombustible material. Exceptions: 134 pdf_text
4 4. Add a new Section 3306.10 to read: "3306.10 Loads on pedestrian protection structures. No additional structures, including field offices, construction equipment, materials, signs, displays, ornamentation or shall be erected or placed upon a construction canopy or similar pedestrian protection structure until plans identifyin are submitted to the building official and a permit is issued, authorizing the construction activity or loading." 209 pdf_text
4 4. Delete the exception to Section 708.4.1. 58 pdf_text
4 4. Class I manual dry standpipes are allowed in parking garages and parking facilities that ar freezing temperatures, provided that the hose connections are located as required for Class II s accordance with Section 905.5." 72 pdf_text
4 4. The basic design wind speed, V, for use in the design of Risk Category IV structures shall be 119 m/s)." 149 pdf_text
4 4. Notwithstanding Section 14B-1-003(5), retain "International Fire Code" in footnote c to Table 414.2.5(1). 33 pdf_text
4 4 S NS S NS S NS S NS S NS S NS S NS S NS S NS S A, E N h N g, h 45 pdf_text
4 4. Delete Sections 1402.6 and 1402.7. 128 pdf_text
4 4. Revise the exceptions to Section 1015.4 to read: "Exceptions: 99 pdf_text
4 4. Revise Section 1705.2.3 by deleting "in buildings, structures and portions thereof." 157 pdf_text
4 4. Changes in elevation of three or fewer risers within or accessory to individual dwelling units and s in Group R-2, R-3 and R-5 do not require handrails. 97 pdf_text
4 4. Revise Section 1107.5.1.1 to read: "1107.5.1.1 Accessible units. At least 10 percent, but not less than one, of the dwelling units and sleeping units shall be Accessible units." 113 pdf_text
4 4. Revise Section 1703.4 to read: "1703.4 Performance. Specific information consisting of test reports conducted by an approved agency in accordance with the appropriate r standards, or other such information as necessary, shall be provided for the building official to confirm that a product assembly meets applicable code requirements." 155 pdf_text
4 4. A multistory unit is not required to be accessible if a single-story Type A unit of equivalent area is provided as part of the planned development. For purposes of this section, "equivalent t means a net floor area within 70 square feet (6.5 m2). 116 pdf_text
4 4. Exterior exit stairways and ramps serving occupiable rooftops above portions of buildings one story above grade plane and not more than 15 feet (4572 mm) above adjoining grade are have a separation distance." 104 pdf_text
4 4. Revise the exception to Section 2610.5 to read: "Exception: The aggregate area limitations of light-transmitting plastic skylights shall be increased 100 percent bey limitations set forth in this section where the building is equipped throughout with an automatic sprinkler system in a with Section 903.3.1.1." 195 pdf_text
4 4. Delete Table 3001.3. 198 pdf_text
4 4. Revise exception 2.1 to Section 915.1.4 by replacing "an approved" with "a." 81 pdf_text
4 4. Revise exception 2 to Section 1009.4.2 by replacing "an automatic sprinkler system" with "a supervised automati system." 92 pdf_text
4 4. Delete Section 419.5. 33 pdf_text
4 4. Revise Section 1204.4 by replacing "dwelling unit" with "single dwelling unit." (Amend Coun. J. 6-25-21, p. 32180, Art. II, § 21; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 15) 123 pdf_text
4 4. Closed ties or spirals where required by Section 1810.3.9.4.2 shall be permitted to be limit feet (914 mm) of deep foundation elements 10 feet (3048 mm) or less in depth supporting Gro R-5 and U occupancies of Seismic Design Category D, not exceeding two stories of light-fram construction." 174 pdf_text
4 4. Revise Section 1028.4.1 by replacing "Group R-3 and U occupancies" with "Group R-3, R-5 and U occupancies occupancies in buildings with no more than 4 stories above grade plane." 105 pdf_text
4 4. Revise Section 311.3 to delete "Fresh fruits and vegetables in nonplastic trays or containers," "Ivory" and "Parkin open or enclosed." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 6) 23 pdf_text
4 4. Alarm signals shall produce a sound that is distinctive from other sounds used during normal operation." 76 pdf_text
4 4. Revise Section 1804.6 to read: "1804.6 Compacted controlled fill material. Where shallow foundations will bear on compacted controlled fill material, the compacted controlled fill shall compl provisions of a geotechnical report acceptable to the building official, as set forth in Section 1803. Exception: Compacted controlled fill material 12 inches (305 mm) in depth or less need not comply with a g report, provided that the in-place dry density is not less than 90 percent of the maximum dry density at optim content determined in accordance with ASTM D1557. The compaction shall be verified by special inspection with Section 1705.6." 164 pdf_text
4 4. Wood veneers shall comply with this section and Section 1404.5." 131 pdf_text
4 4. Exhaust shall be at the top of the atrium and intake at the bottom. 78 pdf_text
4 4. Revise Section 803.15.1.1 by deleting "inorganic or." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 26) 65 pdf_text
4 4. Floors and roofs: A/AF = 0.00050 where: A = Total leakage area, square feet (m2). AF = Unit floor or roof area of barrier, square feet (m2). Aw = Unit wall area of barrier, square feet m2). The leakage area ratios shown do not include openings due to gaps around doors and operable windows. The total le the smoke barrier shall be determined in accordance with Section S101.5.1 and tested in accordance with Section S1 S101.5.1 Total leakage area. Total leakage area of the barrier is the product of the smoke barrier gross area multiplied by the allowable le ratio, plus the area of other openings such as gaps around doors and operable windows. 221 pdf_text
4 4. In industrial facilities, mezzanines used for control equipment are permitted to be glazed on all sides. 40 pdf_text
4 4. Factory and Industrial (see Section 306): Groups F-1 and F-2. 19 pdf_text
4 4. Panels shall be mounted vertically on a wall. 79 pdf_text
4 4. Revise Section 1809.10 by replacing "Seismic Design Categories D, E and F" with "Seismic Design Category D. 170 pdf_text
4 4. Add a new Section 907.1.3.1 to read: "907.1.3.1 Notification appliances. Occupant notification appliances shall be red. Where approved by the fire code official, occupant notification applian 73 pdf_text
4 4. Delete Section 1403.5.3. 128 pdf_text
4 4. Spaces greater than 1,000 square feet (93 m2) but less than 3,000 square feet (280 m2) in ar used exclusively for archival storage or for product storage in a business or mercantile occupa required to be on an accessible route." (Amend Coun. J. 1-26-22, p. 43756, Art. II, § 13) 110 pdf_text
4 4. Delete the following standards under ASME: ASME/A17.1–2016/CSA B44–16; A17.7–2007/CSA B44–07(R20 216 pdf_text
4 4. Insert a new Section 1613.4 to read: "1613.4 Seismic design requirements for buildings assigned to Seismic Design Category A. Buildings and other structures assigned to Seismic Design Category A need only comply with the requirements of thi Nonstructural components of buildings and structures in Seismic Design Category A are exempt from seismic desig Exception: Tanks assigned to Risk Category IV shall satisfy the freeboard requirements of Section 15.6.5.1 o 153 pdf_text
4 4. Revise Section 718.2.7 by replacing "an approved material" with "a noncombustible material." 63 pdf_text
4 4. Delete Section 3002.5. 198 pdf_text
4 4. High-rise buildings containing Accessible units or Type A units. 111 pdf_text
4 4. Delete the second sentence in Section 509.4.1. 47 pdf_text
4 4. Revise exception 2 to Section 1027.6 by deleting "approved." 104 pdf_text
4 4. Revise Section 412.3.2 to read: "412.3.2 Construction. Aircraft hangars shall be of Type I or II construction. Where hangars have basements, floors over basements shall be construction and shall be made tight against seepage of water, oil or vapors. There shall not be openings or communi basements and the hangar. Access to basements shall be from the exterior only." 32 pdf_text
4 4. Revise Section 901.5 to read: "901.5 Acceptance tests. Fire protection systems shall be tested in accordance with the requirements of this code and the Chicago Fire Preven Where required, the tests shall be conducted in the presence of the fire code official. Tests required by this code, the Prevention Code and the standards listed in this code shall be conducted at the expense of the owner. It shall be unla portions of a structure until the required fire protection systems within that portion of the structure have been tested 67 pdf_text
4 4. Revise the first sentence of Section 713.13.4 to read: "Waste or linen chutes shall discharge into an enclosed room separated by fire barriers with a fire-resistance rating n hours and constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Secti both." 60 pdf_text
4 4. Revise note m to Table 307.1(1) to delete "Section 5003.1.2 of." 20 pdf_text
4 4. Revise exceptions 1 and 2 to Section 1003.5 to read: "1. A single step with a maximum riser height of 8 inches (203 mm) is permitted at exterior doors not requir accessible by Chapter 11 in Groups F, H, R-2, R-3, R-5, S and U. 85 pdf_text
4 4. Revise Section 1406.10.2 by replacing "an approved" with "a." 132 pdf_text
4 4. Revise the exception to Section 2406.4.7 to read: "Exception: Glazing that is protected by a guard complying with Sections 1015 and 1607.8." 188 pdf_text
4 4. Delete Section 1805.1.2.1. 165 pdf_text
4 4 See Note f. Not Permitted Not Permitted Not Permitted NP Not Permitted 61 pdf_text
4 4. Revise Section 405.8 and its subsections to read: "405.8 Standby and emergency power. A standby power system complying with Section 2702 shall be provided for the standby power loads specified in Se An emergency power system complying with Section 2702 shall be provided for the emergency power loads specifie 27 pdf_text
4 4. Replace each occurrence of "NFPA 70" with "the Chicago Electrical Code." 2 pdf_text
4 4. Revise Section 916.6 by deleting "approved." 82 pdf_text
4 4. Revise Section 3303.6 to read: "3303.6 Utility connections. Service utility connections shall be discontinued and capped in accordance with the rules and requirements of the util 208 pdf_text
4 4. Revise Section 712.1.8 by replacing "Approved vertical" with "Vertical." 59 pdf_text
4 4. Group A occupancies with an aggregate occupant load of less than 300 persons shall be separated main occupancies by construction providing a fire-resistance rating of not less than 1 hour in building protected throughout by an automatic sprinkler system in accordance with Section 903.3.1.1. 45 pdf_text
4 4. Delete Section 2702.1.8. 196 pdf_text
4 4. Revise Table 1004.5 by revising the entries under "Day care" to read: "Day care | Children under 2 | 55 net All others | 35 net" 85 pdf_text
4 4. Revise Section 504.3 to read: "504.3 Height in feet. The maximum building height, in feet, of a building shall not exceed the limits specified in Table 504.3. Exception: Towers, spires, minarets, steeples and other rooftop structures with a footprint not exceeding 25 ground area of the building on which they are erected shall be constructed of materials consistent with the req construction of the building except where other construction is permitted by Section 1510.2.4. Such rooftop s not be used for habitation or storage. The rooftop structures shall not extend more than 60 feet (18.3 m) abov building height where of noncombustible materials and shall not extend more than 20 feet (6096 mm) above t building height where of combustible materials (see Chapter 15 for additional requirements)." 36 pdf_text
4 4. Approved engineering analysis based on a comparison of building element, component or assembly desig resistance ratings as determined by the test procedures set forth in ASTM E119 or UL 263." 51 pdf_text
4 4. Revise Section 410.2.7.1 by deleting "approved." 32 pdf_text
4 4. Revise Section 1507.4.2 by deleting "approved." 136 pdf_text
4 4. Revise Section 706.4 to read: "706.4 Fire-resistance rating. Fire walls shall have a fire-resistance rating of not less than 4 hours." 57 pdf_text
4 4. Where parking is provided within or beneath a building, accessible parking spaces shall be provid beneath the building. TABLE 1106.2 ACCESSIBLE PARKING SPACES FOR R-2, R-3 AND R-4 OCCUPANCIES 111 pdf_text
4 4. Revise item 14 in Section 603. 1 to read: "14. Blocking such as for handrails, millwork, cabinets and window and door frames in exterior walls or in i and partitions where the required fire-resistance rating is 1 hour or less." 49 pdf_text
4 4. Annunciator unit visually indicating the location of the elevators and whether they are operational 80 pdf_text
4 4. Operable windows that are provided with window opening control devices that comply with AST Exception: In Group R-2 and R-5 occupancies this section only applies where either: 100 pdf_text
4 4. Revise Section 1029.6 to read: "1029.6 Capacity of aisle for assembly. The required capacity of aisles shall be not less than that determined in accordance with Section 1029.6.1 where indo seating is provided and Section 1029.6.3 where open-air assembly seating is provided." 105 pdf_text
4 4. Delete Section 503.1.3. 36 pdf_text
4 4. Delete Section 806.3. 65 pdf_text
4 4. Revise the exceptions to Section 2607.4 by deleting "approved." 194 pdf_text
4 4. Revise exception 2 to Section 905.3.2 by deleting "automatic dry and semiautomatic dry standpipes or." 72 pdf_text
4 4. Outdoor viewing areas. 119 pdf_text
4 4. Revise Section 2405.5 by replacing "approved labeling agency" with "approved agency." 188 pdf_text
4 4. Revise Section E104.1 to read: "E104.1 General. Transient lodging and assisted living facilities shall be provided with accessible features in accordance with Section I-3 occupancies shall be provided with accessible features in accordance with Section E104.2." 220 pdf_text
4 4. Revise Section 1704.2.4 to read: "1704.2.4 Report requirement. Special inspection agencies shall keep records of special inspections and tests. The special inspection agency shall su of special inspections and tests to the owner and to the registered design professional in responsible charge. Reports that work inspected or tested was or was not completed in conformance to permitted construction documents. Discre brought to the immediate attention of the contractor for correction. If they are not corrected, the discrepancies shall b the attention of the building official and to the registered design professional in responsible charge prior to the comp phase of the work. The building official may require that a final report documenting required special inspections and correction of any discrepancies noted in the inspections or tests, be submitted to the building official prior to occupan 156 pdf_text
4 4 S NS S NS S NS S NS S NS S NS S NS S NS S NS S OCCUPANCY A, E I-1 a, I-3, I-4 I-2 R a F-2, S-2 b, U B e, M F-1, S-1 H-1 H-2 H-3, 45 pdf_text
4 4. Revise Section 705.5 to read: "705.5 Fire-resistance ratings. Exterior walls shall be fire-resistance rated in accordance with Tables 601 and 602 and this section. For other than G occupancies, the required fire-resistance rating of exterior walls with a fire separation distance of 10 feet (3048 mm shall only be required to be rated for exposure to fire from the inside. The required fire-resistance rating of exterior fire separation distance of less than 10 feet (3048 mm) shall be rated for exposure to fire from both sides." 54 pdf_text
4 4. Within a dwelling unit in a Group R occupancy." 96 pdf_text
4 4. Revise exception 4 to Section 2603.3 by replacing "approved" with "approved." 192 pdf_text
4 4. Fences not over 10 feet (3048 mm) above adjoining grade. 219 pdf_text
4 4. In Group E-1 occupancies, door swing shall not reduce the required width of corridors by 87 pdf_text
4 4 H-1 – – – – – – – – – – – – – – N NP NP NP NP H-2 – – – – – – – – – – – – – – – – N NP 45 pdf_text
4 4. Delete Section 1609.2 and its subsections and tables. 149 pdf_text
4 4. In Group I-2 and ambulatory care facilities, where such doors are special-purpose h sliding, accordion or folding door assemblies installed in accordance with Section 101 automatic closing by smoke detection in accordance with Section 716.2.6.5. 222 pdf_text
4 4. Revise Section 1013.3 to read: "1013.3 Illumination. Exit signs shall be internally illuminated. Exception: Visual character signs required by Section 1013.14 shall be internally or externally illuminated at Tactile signs required by Section 1013.4 need not be provided with illumination." 98 pdf_text
4 4. The remote room shall be immediately adjacent to the adjoining room. 123 pdf_text
4 4. Revise item 1 in Section 1603.1.4 to read: "1. Basic design wind speed, V, miles per hour or allowable stress design wind speed, Vasd, as determined in accor 144 pdf_text
4 4. Delete the first sentence of Section 1605.2.1. 146 pdf_text
4 4. Exterior stairways that are not required to comply with Section 1009.3." 96 pdf_text
4 4, R-5 or I, including: Bed-and-breakfast establishments Care facilities that provide accommodations for 5 or fewer individuals receiving care Congregate living facilities (nontransient) with 16 or fewer occupants Congregate living facilities with accommodation for 10 or fewer transient occupants Hotels with accommodations for 10 or fewer transient occupants 22 pdf_text
4 4. Fuel for equipment shall be stored outside of the building." 214 pdf_text
4 4. Revise Section 3004.3 to read: "3004.3 Conveyors. Conveyors and conveying systems shall comply with Chapter 10 of the Chicago Conveyance Device Code." 199 pdf_text
4 4. Revise Section 506.2.4 to read: "506.2.4 Mixed-occupancy, multistory buildings. Each story of a mixed-occupancy building with more than one story above grade plane shall individually comply wit applicable requirements of Section 508.1. For buildings with more than three stories above grade plane, the building such that the aggregate sum of the ratios of the actual floor area of each story divided by the allowable area of such s determined in accordance with Equation 5-3 based on the applicable provisions of Section 508.1, shall not exceed thr 43 pdf_text
4 4. An attempt to egress shall initiate an irreversible process that shall allow such egress not more than 15 sec pressure is applied to the egress-side door hardware for not more than 1 second. Initiation of the irreversible activate an audible signal in the vicinity of the door. Once the delay electronics have been deactivated, rearmi electronics shall be by manual means only. The time delay shall not be field adjustable." 94 pdf_text
4 4. Doors from individual dwelling or sleeping units of Group R occupancies having an occupant loa are permitted to be equipped with a night latch, dead bolt or security chain, provided such devices are the inside without the use of a key, tool or special knowledge. 94 pdf_text
4 4. Revise Section 303.4 to insert, alphabetically: "Trading floors." 19 pdf_text
4 4. Such observation is specifically required by the building official. 157 pdf_text
4 4. Revise the exceptions to Section 508.2.4 to read: "Exceptions: 44 pdf_text
4 4. Revise the numbered portion of Section 716.1.1 to read: "1. Designs documented in a test report prepared by an approved agency or test results compiled in the UL Certifications Directory, Intertek Directory of Building Products, or another approved source. 61 pdf_text
4 4. Revise item 2 in Section 403.2.1.1 to read: "2. In other than Group F, H, and S occupancies, the fire-resistance rating of the building elements in Type construction, other than the primary structural frame, shall be permitted to be reduced to the fire-resistance r IIA." 24 pdf_text
4 4. Revise Section 2304.10.6 to delete "approved." 184 pdf_text
4 4. Delete Section D101.2 and its subsections. 218 pdf_text
4 (cont. 2) tway. S101.21.4.4 Fan capacity. The supply fan shall be either adjustable with a capacity of not less than 1,000 cfm (0.4719 m 3/s) per specified by a registered design professional to meet the requirements of a designed pressurization sy S101.21.5 Standby power. 230 pdf_text
4.1 4.1. Discharge of interior exit stairways and exterior exit ramps shall be provided with a free and un of travel to at least two distinct exterior exit doors and each exterior exit door is readily visible and ide within 25 feet (7620 mm) and no more than two turns, each not exceeding 90 degrees (1.57 rad), from termination of the enclosure. There shall be no dead-end corridors or similar conditions exceeding 10 mm) in length adjacent to the point of termination of the enclosure. 104 pdf_text
4.1 4.1. Revise Table 414.2.5(2) by deleting "Tables 5704.3.6.3(4) through 5704.3.6.3(8) and 5704.3.7.5.1 of". 33 pdf_text
4.1 4.1. A stairway complying with Section 1011. 125 pdf_text
4.2 4.2. A stairway with a clear width of not less than 20 inches (508 mm), with risers not less th (178 mm) and not more than 10 inches (254 mm) in height and a tread depth equal to 20 inche minus four-thirds of the riser height and with a handrail on one side. The stairway shall have least 6 feet 2 inches (1880 mm). Where the ceiling height of the loft is less than 6 feet 2 inches the location where the stairway meets the loft, the top of the stairway shall be a landing platfor than 20 inches (508 mm) in length and width, located not more than 18 inches (457 mm) verti finished floor of the loft. 125 pdf_text
4.2 4.2. The entire area of the level of exit discharge is separated from areas below by construction confo fire-resistance rating for the enclosure. 104 pdf_text
4.3 4.3. The building is protected throughout by an automatic sprinkler system installed in accordance w 105 pdf_text
4.3 4.3. A permanent ladder with a rung width of not less than 12 inches (305 mm) and 10-inch ( inch (356 mm) spacing between rungs installed at an incline between 70 to 80 degrees from ho 125 pdf_text
4.4 4.4. An alternating tread device complying with Section 1011.14. 126 pdf_text
4.4 4.4. Means of egress components are separated in accordance with Exception 1.4." 105 pdf_text
4.5 4.5. A ship's ladder with a clear width of 20 inches (508 mm) complying with Section 1011.1 126 pdf_text
40 40. Revise the title and first sentence of Section 1810.3.11.2 to read: "1810.3.11.2 Seismic Design Category D. For structures assigned to Seismic Design Category D, deep foundation element resistance to uplift forces or rotation shall be provided by anchorage into the pile cap, designed considering the combined effect of axial forces due to upli moments due to fixity to the pile cap." 175 pdf_text
40 40. Revise the definition of "certificate of compliance" to read: "CERTIFICATE OF COMPLIANCE. A certificate stating that materials and products meet specified standards or done in compliance with permitted construction documents." 5 pdf_text
40 40. Revise Section 903.4.1, excluding the exceptions, to read: "903.4.1 Monitoring. Alarm, supervisory and trouble signals shall be distinctly different and shall be automatically transmitted to a supervi 71 pdf_text
40 40. Revise Section 907.4.2.1 by replacing "200 feet (60 960 mm)" with "100 feet (30.5 m)." 77 pdf_text
403.4.9.1 403.4.9.1 Main electrical service equipment. All main electrical service equipment shall be installed in vaults or outdoor locations. 26 pdf_text
403.4.9.2 403.4.9.2 Construction. Electrical equipment rooms shall be enclosed with fire barriers constructed in accordance with Section 707 o assemblies constructed in accordance with Section 711, or both. The fire-resistance rating of the enclosure sh accordance with Section 110.26 of the Chicago Electrical Code. 26 pdf_text
403.4.9.3 403.4.9.3 Sump pump. Where electrical service equipment is installed in the lowest story, the electrical equipment room shall be pro sump pump." 26 pdf_text
403.6.1 403.6.1 Fire service access elevator. A minimum of one fire service access elevator shall be provided in accordance with Section 3007. Each fire s elevator shall have a capacity of not less than 3,500 pounds (1588 kg) and shall comply with Section 3002.4. (Amend Coun. J. 7-24-19, p. 3646, § 26; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 3) 26 pdf_text
405.7.1 405.7.1 Number of exits. Each floor level shall be provided with not fewer than two exits. Where compartmentation is required by Sect each compartment shall have not fewer than one vertical exit and not fewer than one exit access doorway into compartment." 27 pdf_text
405.8.1 405.8.1 Standby power loads. The following are classified as standby power loads: 27 pdf_text
405.8.2 405.8.2 Emergency power loads. The following are classified as emergency power loads: 27 pdf_text
406.2.8.1 406.2.8.1 Private garages and carports. Private garages and carports shall be separated from other occupancies in the same building in accordance wi 28 pdf_text
406.2.8.2 406.2.8.2 Public garages. Public garages shall be separated from other occupancies in the same building with fire barriers and horizont of noncombustible construction having a fire-resistance rating of not less than 4 hours. Exception: Where the building (including the parking garage) is equipped throughout with an autom system in accordance with Section 903.3.1.1, the required fire-resistance rating shall be not less than 28 pdf_text
406.2.8.3 406.2.8.3 Repair garages. Repair garages shall be separated from other occupancies in the same building with fire barriers and horizon of noncombustible construction having a fire-resistance rating of not less than 4 hours. 28 pdf_text
406.2.8.4 406.2.8.4 Motor fuel-dispensing facilities. Motor fuel-dispensing facilities shall not be located in a building containing other uses or occupancies." 28 pdf_text
406.3.1 406.3.1 Classification. Private garages and carports shall be classified as Group U occupancies. Exception: Private garages and carports on the same lot as a Group R-5 occupancy shall be classifie R-5 occupancy. 28 pdf_text
406.3.2 406.3.2 Area. Each private garage or carport of Type I, II, IIIA or IV construction shall be not greater than 1,000 square fe gross floor area. Each private garage or carport of Type IIIB or VA construction shall be not greater than 80 28 pdf_text
406.3.3 406.3.3 Height. A building of Type IIB, IIIB, or VB construction containing a private garage shall not exceed one story or 12 mm) in building height. 29 pdf_text
406.3.4 406.3.4 Separation. Private garages and carports shall be separated from other buildings and occupancies in accordance with Sec and 406.3.4.2. Carports may be separated from buildings in accordance with Section 406.3.4.3. 29 pdf_text
406.3.4.1 406.3.4.1 Detached private garages. Any exterior wall of a detached private garage which is located less than 6 feet (1829 mm) from anot on the same lot shall have a fire-resistance rating of not less than 1 hour. Openings shall be protected with Section 716. Exception: There may be one doorway not exceeding 21 square feet (1.95 m 2 ) in area, prote self-closing and self-latching door not less fire-resistive than a solid wood door 1 3/4 inches (4 29 pdf_text
406.3.4.2 406.3.4.2 Attached private garages. Private garages and carports attached to another occupancy shall be separated from all other areas of by fire barriers and horizontal assemblies having a fire-resistance rating of not less than 1 hour. Doo between a private garage and other occupancies shall be equipped with either solid wood doors or sol honeycomb core steel doors not less than 1 3/8 inches (34.9 mm) in thickness, or doors in compliance 29 pdf_text
406.3.4.3 406.3.4.3 Carports. A separation is not required between an enclosed occupancy and a carport, provided that the carport i on two or more sides and there are not enclosed areas above. 29 pdf_text
406.3.5 406.3.5 Automatic sprinkler system. Private garages located in a basement and with a capacity for four or more motor vehicles shall be equipped automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. Exception: Where the private garage is open to the atmosphere for a height of not less than 18 inches around not less than 50 percent of its perimeter." 29 pdf_text
406.4.5 406.4.5 Height and area. Public parking garages shall be limited to the allowable heights and areas specified in Sections 504 and 506 for Grou occupancies. Roof parking shall be allowed. 29 pdf_text
406.4.6 406.4.6 Vertical tiers. The number of vertical tiers of parking shall be limited to the values specified in Table 406.4.6. In the case of a parki having a continuous spiral floor, each 9 feet 6 inches (2896 mm) of height, or portion thereof, shall be considered to TABLE 406.4.6 PUBLIC PARKING GARAGE HEIGHT (IN TIERS) 29 pdf_text
406.9.1 406.9.1 Occupancy. Buildings containing parking facilities shall not contain any other occupancy. Exceptions: 30 pdf_text
41 41. Revise Section 903.4.2 to read: "903.4.2 Alarms. An electric bell, located on the exterior of the building above a fire department connection, shall be connected to eac sprinkler system. The bell shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest installed in the system. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actua fire alarm system. A sign shall be placed at a conspicuous location near the bell and shall state: "SPRINKLER ALARM-WHEN BELL CALL FIRE OR POLICE DEPARTMENT." 71 pdf_text
41 41. Revise Section 1810.3.12 to replace "Seismic Design Category D, E or F" with "Seismic Design Category D." 175 pdf_text
41 41. Revise Section 907.4.2.4 by replacing "an approved" with "a." 77 pdf_text
41 41. Revise the definition of "change of occupancy" to read: "CHANGE OF OCCUPANCY. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 5 pdf_text
42 42. Insert the following definitions: "CHICAGO BUILDING CODE. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provi CHICAGO BUILDING REHABILITATION CODE. As defined in Chapter 2 of the Chicago Construction Code Administrative Provisions. CHICAGO CONSTRUCTION CODES. As defined in Chapter 2 of the Chicago Construction Codes Administrati 5 pdf_text
42 42. Revise Section 1810.3.13 to replace "Seismic Design Category C, D, E or F" with "Seismic Design Category C 175 pdf_text
42 42. Revise Section 903.4.3 by deleting "Approved." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 29; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 14; Amend Coun. J. 6-25-21, II, § 13) 71 pdf_text
42 42 inches in height above the adjacent walking surface U No Yes Yes UNC Yes Yes Yes For SI: 1 foot = 304.8 mm; 1 inch = 25.4 mm; 1 square foot = 0.0929 m 2. U = any material not less fire resistive than untreated wood or plastic composites that comply with ASTM D7032 and Section 2612, unprotected P = any material, protected with construction providing fire-resistance rating as required for exterior wall UNC = noncombustible, unprotected PNC = noncombustible, protected with construction providing fire-resistance rating as required for exterior wall a. Where material type U is allowed, material types P, UNC and PNC shall also be allowed; where material type P is allowed, material types UNC and allowed; where material type UNC is allowed, material type PNC shall also be allowed. b. Egress balconies shall also comply with Section 1021. Exterior exit stairways and exterior exit ramps shall also comply with Section 1027. TABLE 705.2.2 PROJECTIONS FROM WALLS OF TYPE III, IV OR V CONSTRUCTION a 53 pdf_text
42 42. Revise Section 907.4.3 by deleting "approved." 77 pdf_text
420.9.1 420.9.1 Shared cooking facilities. In Group R occupancies, rooms or indoor spaces that contain cooking facilities with domestic cooking applia the occupants of more than one dwelling unit or sleeping unit shall be in accordance with all of the following 34 pdf_text
43 43. Revise Section 907.4.3.1 by replacing "approved" with "accepted." 77 pdf_text
43 43. Revise the exception to Section 1810.3.13 to read: "Exception: In Group R-3, R-4, R-5 and U occupancies of light-frame construction, deep foundation elements supp foundation walls, isolated interior posts detailed so the element is not subject to lateral loads or exterior decks and pa subject to interconnection where the soils are of adequate stiffness." 175 pdf_text
43 43. Delete the definition of "children’s play structure." 6 pdf_text
44 44. Delete the exception to Section 907.5. 77 pdf_text
44 44. Revise section 1810.4 by adding the following sentence at the end: "Where installing drilled shafts through unstable soils or soft clay, the installation procedures shall include casing or as recommended by the registered geotechnical engineer. The registered geotechnical engineer shall analyze the soi squeeze-in potential in soft clay." 175 pdf_text
44 44. Insert the following definitions: "CIRCULATION PATH (for Chapter 11). An exterior or interior way of passage provided for pedestrian travel in not limited to: pedestrian walkways, hallways, courtyards, elevators, platform lifts, ramps, stairways and landings. CITY DATUM. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions. CITY FIRE ALARM BOX. A device wired directly to the City’s emergency communications system and capable an alarm signal." 6 pdf_text
45 45% Unprotected, Sprinklered (UP, S) i No Limi Protected (P) No Limi 55 pdf_text
45 45. Delete the definition of "climate zone." 6 pdf_text
45 45. Revise Section 907.5.1 to read: "907.5.1 Presignal feature. Fire alarm systems in the following buildings shall be provided with a presignal feature: 77 pdf_text
45 45. Revise Section 1810.4.4 to read: "1810.4.4 Preexcavation. The use of jetting, augering or other methods of preexcavation shall be allowed where recommended by the registere engineer. Where permitted, preexcavation shall be carried out in the same manner as used for deep foundation eleme load tests and in such a manner that will not impair the carrying capacity of the elements already in place or damage structures. Element tips shall be advanced below the preexcavated depth until the required resistance or penetration i 175 pdf_text
46 46. Insert the following definition: "CLOSED-CIRCUIT TELEPHONE (for Chapter 11). A telephone with a dedicated line such as a house phone, or phone that must be used to gain entry to a facility." 6 pdf_text
46 46. Delete Section 907.5.2.2 and its subsections. 77 pdf_text
46 46. Revise Section 1810.4.5 to read: "1810.4.5 Vibratory driving. 175 pdf_text
47 47. Revise the definition of "closed system" to read: "CLOSED SYSTEM. As defined in Chapter 2 of the Chicago Fire Prevention Code." 6 pdf_text
47 47. Revise Section 907.5.2.3.1, including its exception, to read: "907.5.2.3.1 Public use areas, common use areas and employee work areas. Visible alarm notification appliances shall be provided in public use areas and common use areas. Where employee have audible alarm coverage, visible alarms shall be provided at time of initial installation." 77 pdf_text
47 47. Revise Section 1810.4.8 to read: "1810.4.8 Hollow-stem augered, and drilled displacement cast-in-place elements. Where concrete or grout is placed by pumping through a hollow-stem auger, the auger shall be permitted to rotate in direction during withdrawal. As the auger is withdrawn at a steady rate or in increments not to exceed 1 foot (305 m or grouting pumping pressures shall be measured and maintained high enough at all times to offset hydrostatic and la pressures. Concrete or grout volumes shall be measured to ensure that the volume of concrete or grout placed in each equal to or greater than 110 percent of the theoretical volume of the hole created by the auger. Where the installation element is interrupted or a loss of concreting or grouting pressure occurs, the element shall be redrilled to 5 feet (152 the elevation of the tip of the auger when the installation was interrupted or concrete or grout pressure was lost and r Augered cast-in-place elements shall not be installed within six diameters center to center of an element filled with c grout less than 12 hours old, unless approved by the building official. If the concrete or grout level in any completed due to installation of an adjacent element, the element shall be replaced. All piles shall have a full-length reinforcing centralizer at the tip." 176 pdf_text
48 48. Revise Table 907.5.2.3.2 by replacing "6 to 25" with "2 to 25." 77 pdf_text
48 48. Revise Section 1810.4.9 to read: "1810.4.9 Socketed drilled shafts. The rock socket and pipe or tube casing, if any, of socketed drilled shafts shall be thoroughly cleaned of foreign mat filling with concrete. Steel cores shall be bedded in concrete or sand/cement grout at the base of the rock socket. Con sand/cement grout shall be placed using a tremie method." 176 pdf_text
48 48. Delete the definition of "coastal A zone." 6 pdf_text
49 49. Delete item 3 to Section 1810.4.10. 176 pdf_text
49 49. Delete the definition of "coastal high-hazard area." 6 pdf_text
49 49. Revise Section 907.5.2.3.3 by adding the following at the end: "Visible alarm notification appliances, arranged so the flashing light beam is visible in all occupiable spaces within t be installed by the owner within dwelling units and sleeping units on an as-needed basis at the request of an occupant disability." 77 pdf_text
5 5 S-1 NS UL 39 pdf_text
5 5. Revise item 1 in Section 1406.10.3 to read: "1. The MCM system has passed tests conducted in accordance with NFPA 286 and the acceptance criteria o 132 pdf_text
5 5. Revise the numbered items in Section 903.2.1.2 to read: 67 pdf_text
5 5 R-5 NS UL 39 pdf_text
5 5. Revise Table 1807.1.6.3(1) by: a. Deleting the columns for 30 and 45 psf per foot; b. Deleting all rows for maximum unbalanced backfill height of 7 feet or greater. c. Deleting note f. 168 pdf_text
5 5. Revise Table 1004.5 by revising the entries under "Exercise rooms" to read: "Exercise rooms | With equipment | 50 gross Open floor | 20 net" 85 pdf_text
5 5. Revise the title and first sentence of Section 1029.6.1 to read: "1029.6.1 Indoor assembly seating. The required capacity in inches (mm) of the aisles for indoor assembly seating shall be not less than the occupant lo the egress element in accordance with all of the following, as applicable:" 105 pdf_text
5 5. Revise Section 712.1.9 to read: "712.1.9 Two-story openings. In other than Groups H, I-2 and I-3, a vertical opening that is not used as one of the applications listed in Sections 71 59 pdf_text
5 5. Revise Section 901.6 and its subsections to read: "901.6 Supervisory service. Where required, fire protection systems shall be monitored by a supervising station in accordance with NFPA 72 or city fire alarm box in accordance with Section 919. A provider of supervising station services shall notify the fire cod less than 48 hours before terminating services to a building. 67 pdf_text
5 5. Revise Section 403.2.1.2 by replacing "420 feet (128 m)" with "400 feet (122 m)." 24 pdf_text
5 5. Revise Section 1504.8 to read: "1504.8 Surfacing and ballast materials. For a building with a mean roof height exceeding that permitted by Table 1504.8 based on the exposure category, the materials shall not be used on the roof: 135 pdf_text
5 5. Revise Section 713.13.6 by deleting "approved." 60 pdf_text
5 5. Delete exceptions 6 and 8 to Section 1010.1.2. 93 pdf_text
5 5. Revise exception 2 to Section 1028.4.2 by replacing "Group R-3" with "Group R-3 or R 5." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 52; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 11; Amend Coun. J. 12-14-2 Art. III, § 5) 105 pdf_text
5 5. Revise Section 306.3 to insert, alphabetically: "Chilled water plants." 20 pdf_text
5 5. Group E-2 occupancies having a capacity of 100 or more children. 83 pdf_text
5 5. Revise Section 1803.5.2 to read: "1803.5.2 Questionable soil or fill. Where the classification, strength or compressibility of the soil or fill is in doubt or where a load-bearing value super specified in this code is claimed, the building official shall require that a geotechnical investigation be conducted." 163 pdf_text
5 5 to less than 10 Type of Projection Material Type Fire Separation Distance (fee 53 pdf_text
5 5. Revise Section 704.13.1 to read: "704.13.1 Fire-resistance rating. The application of SFRM shall be consistent with the fire-resistance rating and the listing, including, but not limited size of structural element, minimum thickness and dry density of the applied SFRM, method of application, substrate conditions and the use of bonding adhesives, sealants, reinforcing or other materials." 52 pdf_text
5 5. Structures that require special consideration of their response characteristics and environment that addressed by this code or ASCE 7 and for which other regulations provide seismic criteria, such as ve bridges, electrical transmission towers, hydraulic structures, buried utility lines and their appurtenanc reactors. 152 pdf_text
5 5. Revise Section 1408.10.3 by replacing "is specifically approved based on" with "has passed." 133 pdf_text
5 5. Installation and anchorage of vibration isolation systems in structures assigned to Seismic Category C or D where the permitted construction documents require a nominal clearance of 1 mm) or less between the equipment support frame and restraint. 160 pdf_text
5 5,0 SM NP NP NP NP NP NP NP N H-2 NS c, d 41 pdf_text
5 5. Revise Section 1705.2.4 by deleting "approved." 157 pdf_text
5 5. Revise Table 707.3.10 by adding "U" to the third row and deleting the fourth row. 58 pdf_text
5 5. Guards shall be provided at the open side of lofts. Loft guards shall be not less than 36 inches (91 height or one-half of the clear height to the ceiling, whichever is less. Exception: Lofts with guardrails that meet the requirements of the Consumer Products Safety Commi beds. 126 pdf_text
5 5,0 S1 UL UL UL UL 41 pdf_text
5 5. Corridors, at intervals not exceeding 75 feet (22.9 m). 77 pdf_text
5 5 R-2 NS UL 39 pdf_text
5 5. Revise Section 1809.11 by deleting "approved." 170 pdf_text
5 5. Revise Section 3004.3.1 to read: "3004.3.1 Enclosure. Conveyors and related equipment connecting successive floors or levels, other than on construction sites, shall be en shaft enclosures complying with Section 713." 199 pdf_text
5 5. Dormers that do not have a low-sloped roof, are no higher than the highest point of the roo which they are located and do not exceed one-third of the horizontal area of the roof plane in located shall not be considered in determining building height. 17 pdf_text
5 5. Revise Section 1604.7 by replacing "approved" with "accepted." 145 pdf_text
5 5. Flights of stairs that serve as stepped aisles for seating areas shall have handrails either at one or the aisle or within the aisle width." 97 pdf_text
5 5 to less than 10 Cornices, eave overhangs, sunshades, bay windows, oriel windows and similar decorative projections on buildings not exceeding 40 feet in building height U No Yes Yes P Yes Yes Yes Cornices, eave overhangs, sunshades, bay windows, oriel windows and similar decorative projections on buildings greater than 40 feet in building height U No No No UNC No Yes Yes P No No No PNC Yes Yes Yes Gutters and downspouts on buildings not exceeding 40 feet in building height U No Yes Yes UNC Yes Yes Yes Gutters and downspouts on buildings greater than 40 feet in building height U No No No UNC Yes Yes Yes Exterior balconies, each not exceeding 100 square feet in area, on buildings not exceeding 55 feet in building height U No Yes Yes UNC Yes Yes Yes Exterior balconies, each not exceeding 100 square feet in area, on buildings greater than 55 feet in building height U No No No UNC Yes Yes Yes Decks laid directly on the ground without airspace below U Yes Yes Yes Decks not exceeding 400 square feet in area U No Yes Yes Decks, any area, not more than 6 feet above adjoining ground U No No Yes Decks, any area, any height UNC Yes Yes Yes Weather-protected entries not exceeding 50 square feet in area U Yes Yes Yes Open porches, serving no more than 1 story above grade plane and not more than 200 square feet in area U No Yes Yes Other open porches and exterior exit stairways, serving more than 1 but no more than 4 stories above grade plane U No No No UNC Yes Yes Yes Exterior exit stair 53 pdf_text
5 5. Delete item 5.1.4 in Section 1202.3. 121 pdf_text
5 5. Revise item 2 in Section 1008.3.3 to read: "Rooms or spaces containing fire command centers." 92 pdf_text
5 5. Revise Section 1109.9 to read: "1109.9 Storage. Where fixed or built-in storage elements such as cabinets, coat hooks, shelves, medicine cabinets, lockers, closets an provided in required accessible spaces or for Type A units or Accessible units, at least 5 percent, but not less than one shall be accessible. Exception: Archival storage areas and product storage areas described in Section 1104.4, exception 4 are not accessible." 118 pdf_text
5 5. Add a new Section 1107.5.1.1.1 to read: "1107.5.1.1.1 Beds. In sleeping units having more than 25 beds, at least 5 percent of the beds shall be accessible." 113 pdf_text
5 5. Revise Section 716.2.1 by replacing "Approved fire door" with "Fire door." 62 pdf_text
5 5. Revise Section 406.2.9.1, including its exception, to read: "406.2.9.1 Elevation of ignition sources. Equipment and appliances having an ignition source and located in private garages, repair garages, motor fuel- disp facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches (457 mm) ab surface on which the equipment or appliance rests. For the purpose of this section, rooms or spaces that are not part o space of a dwelling unit or sleeping unit and that communicate directly with a private garage through openings shall to be part of the private garage." 28 pdf_text
5 5. Delete the exception to Section 718.4. 63 pdf_text
5 5. Delete Section 705.7. 54 pdf_text
5 5. Delete exception 5 to Section 2603.3. 192 pdf_text
5 5. Revise exception 4 to Section 1027.6 to read: "4. In Group R-2, R-3, and R-5 occupancies not more than four stories above grade plane, exterior exit stai exterior exit ramps are not required to be separated from the interior of the building and openings are not limi exterior exit stairway or exterior exit ramp discharges directly to grade." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 51; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 10) 104 pdf_text
5 5. Panels shall be mounted so that the bottom edge is no less than 18 inches (457 mm) above the floo edge is no more than 74 inches (1880 mm) above the floor. 79 pdf_text
5 5. Revise Section 1106.7.3 by adding the following sentence at the end: "If at-grade parking is provided, at least one accessible space for self-parking of a vehicle shall be provided." (Amend Coun. J. 7-20-22, p. 50878, § 2) 112 pdf_text
5 5. Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in acc listed fire door test procedures. 94 pdf_text
5 5. Revise Section 3001.5 to read: "3001.5 Change in use. A change in use of an elevator from freight to passenger, passenger to freight, or from one freight class to another fre comply with Section 8.7 of Chapter 3 of the Chicago Conveyance Device Code." 198 pdf_text
5 5,0 S1 UL UL UL UL UL 42 pdf_text
5 5. Delete Section 509.4.2 and its subsections. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 19; Amend Coun. J. 6-25-21, p. 32180, Art. II, § 8; Amend Coun. J. 12-14-22, III, § 1) 47 pdf_text
5 5. Delete Section 911.1.5. 80 pdf_text
5 5. The net glazed area of exterior openings shall be at least 8 percent of the aggregate floor ar adjoining room and remote room. 123 pdf_text
5 5. In Group R-1, an accessible route is not required to connect stories or mezzanines within i units, provided the accessible level meets the provisions for Accessible units and sleeping acc for two persons minimum and toilet and bathing facilities are provided on that level. 113 pdf_text
5 5. Revise Section 906.4 to read: "906.4 Cooking equipment fires. Fire extinguishers provided for the protection of cooking equipment shall be of a type compatible with the automatic extinguishing system agent. Cooking equipment involving solid fuels or vegetable or animal oils and fats shall be pr Class K-rated portable extinguisher in accordance with the Chicago Fire Prevention Code." 73 pdf_text
5 5. Revise Section 1605.3 by deleting "or 1605.3.2." 146 pdf_text
5 5. Revise Section 1703.4.1 to read: "1703.4.1 Research and investigation. Sufficient technical data shall be submitted to the building official to substantiate the proposed use of any product, m assembly. If it is determined that the evidence submitted is satisfactory proof of performance for the use intended, th official shall allow the use of the product, material or assembly subject to the requirements of this code. The costs, re investigations required under these provisions shall be paid by the owner." 155 pdf_text
5 5. Revise Section 308.3.1.2 to read: "308.3.1.2 Condition 2. This occupancy condition shall include facilities that provide nursing or medical care and could provide emergency c obstetrics or in-patient stabilization units for psychiatric or detoxification purposes, including but not limited to hosp 21 pdf_text
5 5. Revise Section 1013.4 to read: "1013.4 Raised character and braille signs. Signs stating "AREA OF REFUGE," "EXTERIOR AREA FOR ASSISTED RESCUE," "EXIT," "STAIR" or "FIRE required by Sections 1009.9 and 1013.6.1, in visual characters, raised characters and braille and complying with ICC be provided adjacent to each door to an area of refuge, or providing direct access to an exit stairway, an exterior area rescue, an exit ramp, an exit passageway or the exit discharge." 98 pdf_text
5 5. Revise Section 505.3 by replacing "stories" with "stories above grade plane." 40 pdf_text
5 5 to less than 10 e Unprotected, Nonsprinklered (UP, NS) 55 pdf_text
5 5. Add a new item 6 to Section 1603.1.4 to read: "6. Design base shear(s)." 144 pdf_text
5 5. Revise Section D102.1 to read: "D102.1 Types of construction permitted. Within the fire limits every building hereafter erected shall be either Type IA, IB, IIA, IIIA or IV, except as permitte D105." 218 pdf_text
5 5. Replace each occurrence of "International Fire Code" with "Chicago Fire Prevention Code." 2 pdf_text
5 5. Fire alarm systems. 26 pdf_text
5 5. Insert the following definitions: "ADAPTABILITY or ADAPTABLE (for Chapter 11). The ability of certain building spaces and elements, such a countertops, sinks and grab bars, to be added or altered so as to accommodate the needs of individuals with different degrees of disability. ADAPTABLE DWELLING UNIT (for Chapter 11). A dwelling unit constructed and equipped so it can be conve minimal structural change for use by persons with different types or degrees of disability." 4 pdf_text
5 5. A Group S-1 occupancy where the area used for the storage of upholstered furniture or mattresses exceed feet (232 m 2 )." 69 pdf_text
5 5. A timer shall be provided that automatically deactivates the cooking appliances within a p more than 120 minutes. 34 pdf_text
5 5. Revise Section 2606.7.5 by deleting "approved." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 90) 194 pdf_text
5 5. Revise Section 1023.8 by replacing "an approved" with "a." 103 pdf_text
5 5 to less than 10 Type of Element Material Type Fire Separation Distance 141 pdf_text
5 5 F-2 NS UL 38 pdf_text
5 5. Delete the exception to Section 3002.7. 198 pdf_text
5 5 R-4 h NS d UL 39 pdf_text
5 5. Revise items 2 and 3 of Section 916.7 to read: "2. For toxic gases that are not HPM, sample analysis shall be performed at intervals not exceeding 5 minut accordance with the Chicago Fire Prevention Code. 82 pdf_text
5 5. Other methods approved by the building official." 172 pdf_text
5 5. Motor-vehicle-related occupancies shall be separated from other occupancies in accordance with 45 pdf_text
5 5. Revise Section 1804.7 by replacing "an approved" with "a." 164 pdf_text
5 5. Insert a new Section 910.2.3 to read: "910.2.3 Exhibition areas. Automatic smoke and heat vents in accordance with Section 910.3 shall be installed on the topmost occupied story o areas with a floor area in excess of 10,000 square feet (929 m2). Where the upper surface of a story containing an ex not a roof assembly, a mechanical smoke removal system in accordance with Section 910.4 shall be installed." 79 pdf_text
5 5. Steel in tension Pipes, tubes, helicals or H-piles, where justified in accordance with Section 171 pdf_text
5 5. Revise Section E104.2.1 to read: "E104.2.1 Transient lodging and assisted living facilities. In transient lodging and assisted living facilities, sleeping units with accessible communication features shall be pro accordance with Table E104.2.1. Units required to comply with Table E104.2.1 shall be dispersed among the various units." 220 pdf_text
5 5,000 square feet (464 m 2 )." 69 pdf_text
5 5. Add a new Section 1402.8 to read: "1402.8 Energy conservation. Exterior walls shall meet additional performance requirements found in the Chicago Energy Conservation Code." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 62) 128 pdf_text
5 5. Smoke detectors shall be provided at the ceiling of the atrium and at the perimeter of the atrium o within 15 feet (4572 mm). 78 pdf_text
5 5. Natural ventilation shall not be substituted for mechanical ventilation in rooms or spaces w mechanical ventilation is specifically required by the Chicago Mechanical Code or Chicago E Conservation Code. 120 pdf_text
5 5. Revise Section 912.4 by deleting the last sentence. 81 pdf_text
5 5. Delete Section 1808.6.1. 169 pdf_text
5 5. Revise Section 420.5 by replacing "R-3 and R-4" with "R-3, R-4 and R-5." 34 pdf_text
5 5. Delete Section 2407.1.4 and its subsections. 189 pdf_text
5 5. Revise Section 904.13 by deleting item 3. 71 pdf_text
5 5. Revise note b to Table 2304.11 to delete "approved." 184 pdf_text
5 5. Revise note p to Table 307.1(1) to delete "Sections 5705.5 and 5705.5.1 of." 20 pdf_text
5 5. Name of testing agency and test standard by which the fabric was tested. A copy of the certificate must be kept on site and made available to the building official or fire code official. 202 pdf_text
5 5. Add a new Section 1403.5.4 to read: "1403.5.4 Other metals. Other metals, used as siding, shall conform to the applicable standard listed in Table 1507.4.3(1)." 129 pdf_text
5 5. A facility with more than 30 children under two years of age shall be classified as a Group I-4 occ 20 pdf_text
5 5. Revise the last sentence of Section 1704.2.5.1 to read: "At completion of fabrication, the fabricator shall submit a certificate of compliance to the owner stating that the wor performed in accordance with the permitted construction documents. The certificate of compliance shall be made ava building official." 156 pdf_text
5 5. Revise Section 503.1.4 and its subsections to read: "503.1.4 Occupiable rooftops. A roof level or portion thereof shall be permitted to be used as an occupiable rooftop provided the occupancy of the r occupancy that is permitted by Table 504.4 for the story immediately below the roof. The area of the occupiable roo be included in the building area as regulated by Section 506. Exception: The occupancy located on an occupiable rooftop shall not be limited to the occupancies allowed immediately below the occupiable rooftop where the building is equipped throughout with an automatic spri accordance with Section 903.3.1.1 or 903.3.1.2 and occupant notification in accordance with Section 907.5 is the area of the occupiable rooftop." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 15) 36 pdf_text
5 5. Delete Section 3007.5.2. 200 pdf_text
5 5. Revise Table 1507.4.3(1) to delete the rows for hard lead, lead-coated copper, soft lead, and terne and terne coate 137 pdf_text
5 5. Designs using TIA-222 for antenna-supporting structures and antennas, provided that the extent of Topographic Category 2 escarpments in Section 2.6.6.2 of TIA-222 shall be 16 times the escarpment. 148 pdf_text
5 5. Delete Sections 414.3 through 414.6 and their subsections. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 10; Amend Coun. J. 6-25-21, p. 32180, Art. II, § 4) 33 pdf_text
5 5. Delete Section 410.2.7.2. 32 pdf_text
5 5. Revise Table 412.3.6 by changing the values for Types III, IV and V construction to "NP" and adding a legend b stating "NP = Not permitted." 32 pdf_text
5 5. Revise Section 3202.3, including its subsections, to read: "3202.3 Encroachments 12 feet or more above grade. Encroachments 12 feet (3658 mm) or more above grade shall comply with Sections 3202.3.1 through 3202.3.4. 206 pdf_text
5 5. Revise Section 1003.7 to read: "1003.7 Elevators, escalators and moving walks. Elevators, escalators and moving walks shall not be used as a component of a required means of egress. Exception: Elevators used as an accessible means of egress in accordance with Section 1009.4." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 39) 85 pdf_text
5 5. Revise Section 907.2 to read: "907.2 Where required-new buildings and structures. A fire alarm system installed in accordance with the provisions of this code and NFPA 72 shall be provided in new b structures in accordance with Sections 907.2.1 through 907.2.23 and provide occupant notification in accordance wit 74 pdf_text
5 5. Add a new Section 3302.5 to read: "3302.5 Protection of openings. All stairways, elevator shafts, flues, and other vertical openings in the floors and roof shall be covered or properly pr 208 pdf_text
5 5 to less than 10 Walking surfaces covering no more than one third of the roof area or 500 square feet, whichever is greater, on side protected by a noncombustible parapet wall providing a 2-hour fire-resistance rating, at least 36 inches above the walking surface U Yes Yes Yes Walking surfaces on buildings of Group R-5 occupancy covering more than one third of the roof area, with or without parapet wall FRTW No Yes Yes Walking surfaces covering more than one third of the roof area or on side without a parapet wall U No No Yes UNC Yes Yes Yes Pickets, handrails and similar vertical elements not more than 48 inches in height above the adjacent walking surface U No Yes Yes UNC Yes Yes Yes Vertical elements of pergolas, trellises, arbors, privacy screens and similar structures greater than 42 inches in height above the adjacent walking surface, with 50 percent or more of surface area consisting of regularly distributed openings U b No Yes Yes UNC Yes Yes Yes Vertical elements of pergolas, trellises, arbors, privacy screens and similar structures greater than 42 inches in height above the adjacent walking surface, solid or with less than 50 percent of surface area consisting of regularly distributed openings U b No No Yes UNC Yes Yes Yes Horizontal elements of pergolas, trellises, arbors and similar structures greater than 42 inches in height above the adjacent walking surface U b No Yes Yes UNC Yes Yes Yes 141 pdf_text
5 5. Field inspection and reporting procedures (to include procedures for verification of the installed b where required). 163 pdf_text
5 5. Revise Section 1805.2 to read: "1805.2 Dampproofing. Where hydrostatic pressure will not occur as determined by Section 1803.5.4, floors and walls shall be dampproofed with this section." 165 pdf_text
5 5. Delete Table 706.4. 57 pdf_text
5 5. Revise Section 1505.3 by replacing "approved testing agency" with "approved agency." 136 pdf_text
5 5. Revise row 13 of Table 1607.1 be deleting the entry for "on single family dwellings only." 146 pdf_text
5 5,0 S13D UL UL 42 pdf_text
5 5. Revise Section 1806.3 to read: "1806.3 Lateral load resistance. Where the presumptive values of Table 1806.2(1) are used to determine resistance to lateral loads, the calculations s accordance with Sections 1806.3.1 through 1806.3.4. Where the presumptive values of Table 1806.2(2) are used, res lateral loads shall be as provided in the geotechnical report." 168 pdf_text
5 5. The structure does not have response characteristics that make it subject to across-wind loading, v shedding, or instability caused by galloping or flutter. 149 pdf_text
5 5. Revise exception 4 to Section 915.1.5 by replacing "an approved" with "a." 82 pdf_text
5 5. Revise exception 3 to Section 1011.5.2 to read: "3. The maximum riser height shall be 8 inches (203 mm), the minimum tread depth shall be 9 inches (229 minimum winder tread depth at the walkline shall be 9 inches (229 mm) and a nosing projection not less than mm) but not more than 1 1/4 inches (32 mm) shall be provided where the tread depth is less than 10 inches (2 of the following conditions: 96 pdf_text
5 5. Delete the exception to Section 1009.7.2. 92 pdf_text
5 5. The fire-resistance rating of exterior walls shall not be reduced." 218 pdf_text
5 5. Stairway exit doors shall be openable from the egress side and shall only be locked from the opposite side or R-5 occupancies where the only interior access to the dwelling unit is from a single interior exit stairway." 95 pdf_text
5 5. Revise Section 1005.7.1 to read: "1005.7.1 Doors. Doors in any position shall not reduce the required width by more than one-quarter. Exceptions: 87 pdf_text
5 5. Revise Section 1510.6 by replacing "5 feet (1524 mm)" with "15 feet (4572 mm)." 139 pdf_text
5 5. Revise Section 2113.11.2.2 by deleting "an approved." 180 pdf_text
5 5. Revise Section 419.9 to read: "419.9 Plumbing facilities. The nonresidential area of the live/work unit shall be provided with minimum plumbing facilities as specified by the Plumbing Code, based on the function of the nonresidential area. Where the nonresidential area of the live/work unit 33 pdf_text
5 5. Revise exception 2 to Section 717.5.2 by replacing "an approved" with "a." 62 pdf_text
5 5. Revise exception 1 to Section 1020.5 by deleting "smoking lounges." 102 pdf_text
5 5. Revise Section 715.4.1 by replacing "an approved" with "a." 61 pdf_text
5 5. Revise Section 2308.3.1 by replacing "approved anchors" with "other anchors." 185 pdf_text
5 5. Revise the title and first sentence of Section 1810.2.4.1 to read: "1810.2.4.1 Seismic Design Category D. For structures assigned to Seismic Design Category D deep foundation elements on Site Class E or F sites, as determ 170 pdf_text
5 5. Revise exception 2 to Section 2610.6 to read: "2. In Group R-3 or R-5, multiple skylights located above the same room or space with a combined area not limits set forth in Section 2610.4." 195 pdf_text
5 5. Where two exits, exit access doorways, exit access stairways or exit access ramps are requ Group B or Group M tenant space (other than an ambulatory care facility), a reduction in the r separation distance may be approved by the building official where the tenant space is separat other areas of the building by construction with a fire-resistance rating of not less than 1 hour separation distance is sufficient to minimize the chance of both being blocked by smoke or fir 91 pdf_text
5 5. Delete the exception to Section 506.2.4. 43 pdf_text
5 5. Delete Section 905.3.3. 72 pdf_text
5 5. Status indicators and controls for air distribution systems. 80 pdf_text
5 5. Insert the following standard under ASME: "A120.1–2014: Safety Requirements for Powered Platforms and Traveling Ladders and Gantries for Building Maint 216 pdf_text
5 5. Revise Section 2702.2 to read: "2702.2 Where required. Emergency power systems and standby power systems shall be provided where required by Sections 2702.2.1 throug Article 700 of the Chicago Electrical Code." 196 pdf_text
5 5. Where the roof has a slope less than four units vertical in 12 units horizontal (33.3-percent slope), connection shall be located to serve the roof or at the highest landing of an interior exit stairway with roof provided in accordance with Section 1011.12. 72 pdf_text
5 5. Revise Section 2607.5 to read: "2607.5 Automatic sprinkler system. Where the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, percentage area of exterior wall in any story in light-transmitting plastic wall panels and the maximum square foota area given in Table 2607.4 shall be increased 100 percent, but the area of light-transmitting plastic wall panels shall percent of the exterior wall area in any story, or the area permitted by Section 705.8 for unprotected openings, which 194 pdf_text
5 5. Group E-1 occupancies." 111 pdf_text
5 5. Revise exception 4 to Section 714.4.2 by deleting "approved." 60 pdf_text
5 5. Revise Section 2303.1.6.2 by replacing "an approved roof covering" with "a roof covering." 183 pdf_text
5 5. In assembly seating areas, guards required at the end of aisles in accordance with Section 1029.17 have openings that allow passage of a sphere 4 inches (102 mm) in diameter up to a height of 26 inch From a height of 26 inches (660 mm) to 42 inches (1067 mm) above the adjacent walking surfaces, g have openings that allow passage of a sphere 8 inches (203 mm) in diameter. 100 pdf_text
5 5. High Hazard (see Section 307): Groups H-1, H-2, H-3, H-4 and H-5. 19 pdf_text
5 5. Revise Section 3303.7 to read: "3303.7 Fire safety during demolition. Fire safety during demolition shall comply with the applicable requirements of this chapter." 208 pdf_text
5 5. Elevator machine rooms, elevator shafts and machinery spaces. (Automatic sprinklers shall be pro elevator pits.)" 70 pdf_text
5 5. Revise Section 508.3.2 to read: "508.3.2 Allowable building area, height and number of stories above grade plane. 44 pdf_text
5 5. Revise Section 1015.5 to read: "1015.5 Screen porches. Porches and decks that are enclosed with insect screening shall be provided with guards where the walking surface is than 30 inches (762 mm) above the floor or grade below at any point within 36 inches (914 mm) horizontally to the e screening." 100 pdf_text
5 5. Revise Section 1609.3 to read: "1609.3 Basic design wind speed. The basic design wind speed, V, for nominal design 3-second gust wind speeds at 33 feet (10 m) above ground for ex category C for the determination of the wind loads shall be as follows: 149 pdf_text
5 5. Means of egress and exit sign illumination as required by Chapter 10. 27 pdf_text
5 5. Add a new item 3 to Section 708.4.2 to read: "3. In Group R-2 occupancies not more than four stories above grade plane and not exceeding 60 feet (18 2 building height, the attic space shall be subdivided by draftstops into areas not exceeding 3,000 square feet (2 above every two dwelling units, whichever is smaller." 58 pdf_text
5 5. Revise item 19 in Section 603.1 to read: "19. Heavy timber as permitted by Note c to Table 601 and Sections 602.4.3 and 705.2." 49 pdf_text
5 5. Coal and material bins, water towers and trestles of Type IV construction. 219 pdf_text
5 5 R-3 h NS UL 39 pdf_text
5 5,0 S13R UL UL 42 pdf_text
5 5. Replace Table 504.3 as shown: TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE a OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION SEE FOOTNOTES TYPE I TYPE II TYPE III TYPE IV A B A B A B HT OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION SEE FOOTNOTES TYPE I TYPE II TYPE III TYPE IV A B A B A B HT A, B, E, F, H-4 c, M, S, U NS b 37 pdf_text
5 5 to less than 10 Exterior balconies, each not exceeding 100 square feet in area, on buildings not exceeding 55 feet in building height U No Yes Yes UNC, HT Yes Yes Yes Exterior balconies individually exceeding 100 square feet in area P, HT, UNC Yes Yes Yes Decks, any area, any height HT Yes Yes Yes Open porches on buildings of Group R occupancy serving no more than 3 stories above grade plane, not projecting more than 10 feet from the building and not providing more than 54 pdf_text
5 5. Revise Section 1404.3.1, excluding the exceptions, to read: "1404.3.1 Class I and II vapor retarders. Class I or II vapor retarders shall be provided on the interior side of frame walls." 129 pdf_text
5 (cont. 2) For SI: 1 foot = 304.8 mm; 1 inch = 25.4 mm; 1 square foot = 0.0929 m 2. U = any material not less fire resistive than untreated wood or plastic composites that comply with ASTM D7032 and Section 2612, unprotected FRTW = Fire-retardant treated wood P = any material, protected with construction providing fire-resistance rating as required for exterior wall HT = heavy timber construction, complying with Section 2304.11 UNC = noncombustible, unprotected PNC = noncombustible, protected with construction providing fire-resistance rating as required for exterior wall a. Where material type U is allowed, material types P, HT, UNC and PNC shall also be allowed; where material type UNC is allowed, material type PN allowed. b. Combustible pergolas, arbors, trellises, privacy screens and similar structures shall not exceed 12 feet in height above the highest adjacent walking su 141 pdf_text
5 (cont. 2) UL = Unlimited. NP = Not permitted. NS = Buildings not equipped throughout with an automatic sprinkler system. S = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. S13R = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2. S13D = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.3. a. See Chapters 4 and 5 for specific exceptions to the allowable number of stories above grade plane in this table. b. See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies. c. New Group H occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.5. d. The NS value is only for use in evaluation of existing buildings in accordance with the Chicago Building Rehabilitation Code. e. New Group I-1 and I-3 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6. For new Group Condition 1, see Exception 1 of Section 903.2.6. f. New and existing Group I-2 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6 and the Chi Requirements for Existing Buildings. g. For new Group I-4 occupancies, see Exceptions 2 and 3 of Section 903.2.6. h. New Group R-1, R-3 and R-4 occupan 39 pdf_text
5 (cont. 2) ways, other than fire escapes, serving any story more than 4 stories above grade plane PNC Yes Yes Yes Fire escapes UNC Yes Yes Yes Pickets, handrails and similar vertical elements not more than 53 pdf_text
5 (cont. 3) cies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.8. (Amend Coun. J. 7-24-19, p. 3646, §§ 28, 29; Amend Coun. J. 2-19-20, p. 14473, Art. II, § 16; Amend Coun. J. 6-25-21, p. § 5; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 4) 39 pdf_text
5.1 5.1. Revise Section 2303.1.6.3 by replacing "an approved" with "a". 183 pdf_text
5.1 5.1. Insert a new Section 1023.9.2 to read: "1023.9.2 Designation. Stairways shall be designated using letters indicating the compass direction of the location of the stairway within the Exception: Letter-based designation schemes approved by the fire code official." 103 pdf_text
50 50. Revise the definition of "combustible dust" to read: "COMBUSTIBLE DUST. As defined in Chapter 2 of the Chicago Fire Prevention Code." 6 pdf_text
50 50. Revise Section 907.6.3.1 to read: 77 pdf_text
50 50. Revise item 5 to Section 1810.4.10 to read: "5. Micropiles shall be grouted as soon as practical after drilling is completed." 176 pdf_text
502 502 of the Chicago Construction Codes Administrative Provisions. Exceptions: 155 pdf_text
506.1.3 506.1.3 Basements. Basements shall be included in building area where the total area of such basements exceeds the allowable bu a one-story above grade plane building of the same occupancy and construction type. 40 pdf_text
506.1.3.1 506.1.3.1 Maximum area. Every basement exceeding 40,000 square feet (3716 m2) in area shall be subdivided by fire barriers in exceeding 40,000 square feet (3716 m2), provided where the building is equipped throughout with an 40 pdf_text
508.1 508.1. Exception: The grade-level tier is permitted to contain an office, waiting and toilet rooms having a total com not more than 1,000 square feet (93 m2). Such area need not be separated from the open parking garage." 30 pdf_text
51 51. Revise the definition of "combustible fibers" to read: "COMBUSTIBLE FIBERS. As defined in Chapter 2 of the Chicago Fire Prevention Code." 6 pdf_text
51 51. Revise Section 907.6.4 by replacing "300 feet (91 440 mm)" with "200 feet (61 m)." 78 pdf_text
51 51. Revise Section 1810.4.11 by replacing "registered design professional" with "registered geotechnical engineer. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 81; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 18) CHAPTER 14B-19 CONCRETE 176 pdf_text
52 52. Revise the definition of "combustible liquid" to read: "COMBUSTIBLE LIQUID. As defined in Chapter 2 of the Chicago Fire Prevention Code." 6 pdf_text
52 52. Revise Section 907.6.4.1 by replacing "an approved location" with "a location acceptable to the fire code officia 78 pdf_text
53 53. Revise the definition of "common path of egress travel" to read: "COMMON PATH OF EGRESS TRAVEL. That portion of exit access travel distance measured from the most re each room, area or space to that point where the occupants have separate and distinct access to two exits or exit acces to an exterior exit door at the level of exit discharge." 6 pdf_text
53 53. Revise Section 907.6.6 by deleting "approved." 78 pdf_text
539 539–17: Single and Multiple Station Heat Alarms – with Revisions through May 2018." 217 pdf_text
54 54. Revise exception 3 to Section 907.6.6 by replacing "one- and two-family dwellings" with "Group R-5 occupanc 78 pdf_text
54 54. Insert the following definition: "COMMON USE AREAS or COMMON AREAS (for Chapter 11). Areas, including interior and exterior rooms, elements, that are held out for use by all tenants and owners in public facilities and multi-story housing, including but residents of an apartment building or condominium complex, occupants of an office building or the guests of such re occupants. Common use areas or common areas include but are not limited to lobbies, elevators, hallways, laundry r swimming pools, storage rooms, recreation areas, parking garages, building offices, conference rooms, patios, restro telephones, drinking fountains, restaurants, cafeterias, delicatessens and stores." 6 pdf_text
55 55. Revise Section 907.6.6.1 by deleting "unless approved by the fire chief." 78 pdf_text
55 55. Revise the definition of "compressed gas" to read: "COMPRESSED GAS. As defined in Chapter 2 of the Chicago Fire Prevention Code." 6 pdf_text
56 56. Revise Section 907.6.6.2 to read: "907.6.6.2 Termination of monitoring service. Termination of fire alarm monitoring services shall be in accordance with Section 901.6." 78 pdf_text
56 56. Revise the definition of "construction documents" to read: "CONSTRUCTION DOCUMENTS. As defined in Chapter 2 of the Chicago Construction Codes Administrative P Also see "permitted construction documents." 7 pdf_text
57 57. Insert the following definition: "CONVEYANCE DEVICE. As defined in Chapter 2 of the Chicago Conveyance Device Code." 7 pdf_text
57 57. Revise Section 907.7.2 to read: "907.7.2 Record of completion. A record of completion in accordance with NFPA 72 verifying that the system has been installed and tested in accor permit shall be provided to the fire code official." 78 pdf_text
58 58. Revise Section 907.7.3 to read: "907.7.3 Instructions. Operating, testing and maintenance instructions and record drawings ("as-builts") and equipment specifications shall on site or at an approved off-site location." 78 pdf_text
58 58. Revise the definition of "corrosive" to read: "CORROSIVE. As defined in Chapter 2 of the Chicago Fire Prevention Code." 7 pdf_text
59 59. Revise the definition of "court" to read: "COURT. An open space on a lot, other than a yard or portion of a yard, that is unobstructed from its lowest level to bounded, in whole or part, by abutting property lines, exterior building walls or other enclosing devices. Inner Court. A court other than an outer court. Outer Court. A court with at least 30 feet (9144 mm) or 25 percent of its perimeter, whichever is less, abutti a yard at least 3 feet (914 mm) in width or a public way at least 15 feet (4572 mm) in width. " 7 pdf_text
59 59. Revise Section 907.8 by deleting "Section 907.8 of." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 33; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 16; Amend Coun. J. 78 pdf_text
6 6. Revise Section 1006.2.2.1 by replacing "one is permitted to be a fixed ladder" with "one is allowed to be served ladder" and replacing "equal to one-half" with "equal to not less than one-half." 88 pdf_text
6 6. Delete Equation 7-1. 54 pdf_text
6 6. Revise Section 717.5.3 by replacing "fire and smoke dampers" with "fire dampers." 62 pdf_text
6 6. Within individual dwelling units and sleeping units in Group R-2, R-3 and R-5 occupancies, guard have openings that allow passage of a sphere 4 3/8 (111 mm) inches in diameter." 100 pdf_text
6 6. Add a new Section 3303.8 to read: "3303.8 Debris removal. Debris from the demolition of a building or structure shall be removed from the site as demolition progresses. Salvag left on the site, shall be neatly stored." 208 pdf_text
6 6. Revise Section 1507.4.4 to replace "approved manufacturer’s" with "manufacturer’s recommended." 137 pdf_text
6 6. Revise Section 716.5.2 by replacing "Approved fire-protection-rated" with "Fire-protection-rated." 62 pdf_text
6 6. The smoke control system shall have completely automatic control. The automatic-control sequen initiated by activation of either the automatic sprinkler system or smoke detectors in the atrium area. 78 pdf_text
6 6. Replace each occurrence of "International Fuel Gas Code" with "Chicago Fuel Gas Code." 2 pdf_text
6 6. Doors serving roofs not intended to be occupied shall be permitted to be locked preventing entry t from the roof." 94 pdf_text
6 6. Revise Section 505.3.1 by replacing "two-thirds" with "one-half." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 17) 40 pdf_text
6 6. Beach access routes. 119 pdf_text
6 6. Revise Section 2702.2.2 to read: "2702.2.2 Elevators and platform lifts. Standby power shall be provided for elevators and platform lifts as required in Sections 1009.4.1, 1009.5, 3003.1 and 196 pdf_text
6 6. Group E-1 occupancies having an occupant load of more than 100. 83 pdf_text
6 6. Replace Table 1504.8 as shown: TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON 135 pdf_text
6 6. Outside of doors leading to exit stairways. 77 pdf_text
6 6. Revise item 1 in Section 420.6.1 by replacing "15 net square feet (1.4 m2)" with "30 net square feet (2.8 m2)." 34 pdf_text
6 6. Delete all figures and tables included in Section 1609.3. 149 pdf_text
6 6. Revise Section 1008.3.4 to read: "1008.3.4 Operation. The emergency power system shall be in accordance with Article 700 of the Chicago Electrical Code." 92 pdf_text
6 6. Delete the exceptions to Section 714.5.1. 60 pdf_text
6 6. Revise exception 2 to Section 1202.3 to read: "2. Section 1202.3 does not apply to enclosures that are humidified beyond 35 percent during winter months." 121 pdf_text
6 6. Revise exception 9 to Section 1010.1.2 by replacing "Group H" with "Groups E and H." 93 pdf_text
6 6. The fire fighter’s control panel required by Section 909.16 for smoke control systems installed in t 80 pdf_text
6 6. For buildings without low-sloped roofs or occupiable rooftops, building height may be me mean elevation of all roof surfaces above the finished floor of the highest story. 17 pdf_text
6 6. Revise Section 1109.9.2 to read: "1109.9.2 Shelving and display units. Self-service shelves and display units shall be located on an accessible route. Such shelving and display units shall n to comply with reach-range provisions. The clear width of aisles between stacks in libraries shall be 42 inches (1065 minimum. Exception: In existing buildings and alterations, the minimum width of aisles between stacks in libraries sha (915 mm)." 118 pdf_text
6 6. Ventilation and exhaust systems for occupancies and operations involving flammable or co hazards or other contaminant sources as covered in the Chicago Mechanical Code or the Chic Prevention Code shall be provided as required by both codes." 120 pdf_text
6 6. Revise Section 911.1.6 to read: "911.1.6 Required features. The fire command center shall comply with NFPA 72 and shall contain all of the following features: 80 pdf_text
6 6. Revise Section 3202.4 to read: "3202.4 Temporary vestibules. Temporary vestibules shall not be erected for a period of time exceeding 6 months in any 1 year and shall not encroa feet (914 mm) nor more than one-fourth of the width of the sidewalk beyond the property line. Such enclosures shall Chapter 11 and shall not contain seating." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 98) 206 pdf_text
6 6. Revise the definition of "addition" to read: "ADDITION. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 4 pdf_text
6 6. Installation of mechanical and electrical equipment, including duct work, piping systems a structural supports, where automatic sprinkler systems are installed in structures assigned to S Category C or D to verify one of the following: 160 pdf_text
6 6. Revise Section 1604.8.3 to read: "1604.8.3 Decks, porches, exterior balconies and similar structures. Where supported by attachment to an exterior wall, decks, porches, exterior balconies and similar structures shall be anchored to the primary building structure and designed for both vertical and lateral loads as applicable. Such attach be accomplished by the use of toenails or nails subject to withdrawal. Where positive connection to the primary buil cannot be verified, decks, porches, exterior balconies and similar structures shall be self-supporting. Connections of porches, exterior balconies and similar structures with cantilevered framing members to exterior walls or other fram shall be designed for both of the following: 145 pdf_text
6 6. Delete Section 1023.10. 103 pdf_text
6 6. Delete the exceptions to Section 708.4.2. 59 pdf_text
6 6. Revise Section 1505.4 by replacing "approved testing agency" with "approved agency." 136 pdf_text
6 6. Revise the exceptions to Section 706.5 to read: "Exceptions: 57 pdf_text
6 6. Delete exception 6 to Section 1009.8. 92 pdf_text
6 6. Delete Section 2303.1.6.3.1. 183 pdf_text
6 6. Revise Section 907.2.1 and its subsections to read: "907.2.1 Group A. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be Group A occupancies where the occupant load due to the assembly occupancy is 300 or more. Group A occupancies from one another in accordance with Section 707.3.10 shall be considered as a single occupancy for the purposes of section. Portions of Group E occupancies occupied for assembly purposes shall be provided with a fire alarm system the Group E occupancy. Exception: Manual fire alarm boxes are not required where the building is equipped throughout with an auto sprinkler system installed in accordance with Section 903.3.1.1 and the occupant notification appliances will accordance with Section 907.5 upon sprinkler water flow." 74 pdf_text
6 6. Darkened, tinted or opaque glass shall not be used to cover or obscure the panels. Exception: Slightly-tinted glass, as approved by the fire code official. 79 pdf_text
6 6. Revise the exceptions to Section 508.3.3 to read: "Exceptions: 45 pdf_text
6 6 E-1 NS UL 38 pdf_text
6 6. Water tanks and cooling towers conforming to Sections 1510.3 and 1510.4. 219 pdf_text
6 6. Revise Section 1603.1.5 by inserting the following between items 6 and 7: "The following information shall be shown for structures assigned to seismic design category B, C or D:" 144 pdf_text
6 6. Revise Section 904.13.1.1 by deleting "approved." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 30) 71 pdf_text
6 6. Mezzanines in accordance with Exception 3 to Section 505.2.1." 40 pdf_text
6 6 R-1 h NS d UL 39 pdf_text
6 6. Add new exception 5 to Section 1020.5 to read: "5. Use of a corridor as a source of makeup air for exhaust systems in Group R-2 dwelling units and sleepin open directly onto such corridors shall be permitted, provided that each such corridor is directly supplied wit at a rate greater than the rate of makeup air taken from the corridor and the dwelling units and sleeping units with an independent source of air for ventilation." 102 pdf_text
6 6. Delete Section 3007.6 and its subsections except 3007.6.5. 200 pdf_text
6 6. Electrically powered fire pumps. 26 pdf_text
6 6. Revise Section 1005.7.2 to read: "1005.7.2 Other projections. Handrail projections shall be in accordance with the provisions of Section 1014.8. Other projections such as trim an features shall be allowed to project into the required width not more than 1 1/2 inches (38 mm) on each side. Exception: Projections are allowed in corridors within Group I-2 Condition 1 in accordance with Section 40 (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 41; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 21; Amend Coun. J. 6-25-21, II, § 16) 87 pdf_text
6 6. Institutional (see Section 308): Groups I-1, I-2, I-3 and I-4. 19 pdf_text
6 6. Delete the exception to Section 1704.3. 156 pdf_text
6 6. Revise Section 506.3 to replace "public way" with "public way." 43 pdf_text
6 6. Delete Section 1809.12. 170 pdf_text
6 6 feet (1829 mm) horizontally from the building, between the building and a point 6 feet (1829 mm) horizontally fro Exceptions: 17 pdf_text
6 6. Load test requirements. 164 pdf_text
6 6. In Group I-1 and I-2 occupancies, the alarm shall sound at a constantly attended location a mode signaling shall be broadcast throughout the facility." 76 pdf_text
6 6. Revise Section 1015.8 and its subparts to read: "1015.8 Window openings. Where the bottom of the clear opening of an operable window in a dwelling unit, sleeping unit or common area in a occupancy is located less than 36 inches (914 mm) above the finished floor and more than 72 inches (1829 mm) abo grade or other surface below on the exterior of the building, the window shall comply with one of the following: 100 pdf_text
6 6. Revise the first two sentences of Section 2304.11.1.1 to read: "Minimum dimensions of columns shall be in accordance with Table 2304.11. Columns shall be continuous or super throughout all stories." 184 pdf_text
6 6. Revise the exception to Section 1510.6.1 by replacing "Type IA" with "Type I." 139 pdf_text
6 6. Revise Section 1703.6 and its subsections to read: "1703.6 Off-site fabrication. Where structural components or other items regulated by this code are not visible for inspection after completion of a assembly, the owner shall maintain a report of each prefabricated assembly. The report shall indicate the complete de assembly, including a description of the assembly and its components, the basis upon which the assembly is being ev results and similar information and other data as necessary for the building official to confirm conformance to this co 155 pdf_text
6 6. Revise Section 906.6 to read: "906.6 Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or obscured from view. Where a fire extinguisher is likely to be ob of stock, lumber or otherwise, a sign shall be installed and maintained which will indicate the location of the fire exti manner legible at a distance of at least 50 feet (15.2 m)." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 32) 73 pdf_text
6 6. A portable fire extinguisher shall be provided. Installation shall be in accordance with Sect the extinguisher shall be located within a 30-foot (9144 mm) distance of travel from each dom appliance." 34 pdf_text
6 6. Revise Section 306.3 to delete "Metal products (fabrication and assembly)." 20 pdf_text
6 6. The structure does not have a site location for which channeling effects or buffeting in the wake o obstructions warrant special consideration. 149 pdf_text
6 6. Timber In accordance with the ANSI/AWC ND 171 pdf_text
6 6. Revise Section 406.3 and its subsections to read: "406.3 Private garages and carports. Private garages and carports shall comply with Sections 406.2 and 406.3. 28 pdf_text
6 6. Delete Section 1029.6.2 and its subsections. 105 pdf_text
6 6. Revise Section 1403.8 by deleting "approved." 129 pdf_text
6 6. Revise Section 504.4 to read: "504.4 Number of stories above grade plane. The maximum number of stories above grade plane of a building shall not exceed the limits specified in Table 504.4 37 pdf_text
6 6. References within ASCE 7 to Chapter 14 shall not apply, except as specifically required herein." 152 pdf_text
6 6. The floor level of the loft shall be at least 30 inches (762 mm) and no more than 151 inches (3835 the main floor level of the unit. 126 pdf_text
6 6 S-2 NS UL 39 pdf_text
6 6. Revise Section 3004.4 by replacing "an approved" with "a." 199 pdf_text
6 6. Delete item 3 in Section 903.2.1.3. 68 pdf_text
6 6. Revise Section 1806.3.1 by replacing "Table 1806.2" with "Table 1806.2(1)." 168 pdf_text
6 6. Openings between smoke zones with clear ceiling heights of 14 feet (4267 mm) or bank-down capacity of greater than 20 minutes as determined by the design fire size. S101.5.3.1 Group I-1, Condition 2; Group I-2; and ambulatory care facilities. In Group I-1, Condition 2; Group I-2; and ambulatory care facilities, where doors are installed across doors shall be automatic closing by smoke detection in accordance with Section 716.2.6.5 and shall h panel with fire-protection-rated glazing materials in fire protection- rated frames, the area of which sh that tested. S101.5.3.2 Ducts and air transfer openings. Ducts and air transfer openings are required to be protected with a minimum Class II, 250°F (121°C) complying with Section 717. S101.6 Pressurization method. The primary mechanical means of controlling smoke shall be by pressure differences across smoke barriers. Mainten tenable environment is not required in the smoke control zone of fire origin. S101.6.1 Minimum pressure difference. The pressure difference across a smoke barrier used to separate smoke zones shall be not less than 0.05-inch (0.0124 kPa) in fully sprinklered buildings. In buildings permitted to be other than fully sprinklered, the smoke control system shall be designed to achie differences not less than two times the maximum calculated pressure difference produced by the design fire. S101.6.2 Maximum pressure difference. The maximum air pressure difference across a smoke barrier shall be determined by r 222 pdf_text
6 6. In congregate living facilities in Groups R-3 and R-4, an accessible route is not required to stories or mezzanines where Accessible units or Type B units, all common use areas serving Ac and Type B units and all public use areas serving Accessible units and Type B units are on an a route. This exception does not apply to multi-story housing. 113 pdf_text
6 6. Revise row 21 of Table 1607.1 to read: 146 pdf_text
6 6 U NS UL 39 pdf_text
6 6. Revise Section 308.3.2 to read: "308.3.2 Five or fewer individuals receiving medical care. A facility with five or fewer individuals receiving nursing or medical care shall be classified as Group R-3 provided sprinkler system is installed in accordance with Section 903.3.1.3." 21 pdf_text
6 6. Revise Section 2603.4 by replacing "an approved" with "a." 192 pdf_text
6 6. A level within or serving a single dwelling unit, provided all the following criteria are met: 89 pdf_text
6 6. Wind tunnel tests in accordance with ASCE 49 and Sections 31.4 and 31.5 of ASCE 7. 148 pdf_text
6 6. Revise Section 2113.11.3.2 by deleting "an approved." 180 pdf_text
6 6. Revise Section 715.4.2 by replacing "An approved" with "A." 61 pdf_text
6 6. Revise Table 1807.1.6.3(2) by: a. Deleting the columns for 30 and 45 psf per foot; b. Deleting note e. 168 pdf_text
6 6. Revise Table 1404.3.2 by deleting all rows except Zone 5. 129 pdf_text
6 6. Revise Section 1803.5.3 to read: "1803.5.3 Expansive soil or fill. In areas likely to have expansive soil or fill, the registered geotechnical engineer shall perform soil tests to determin soils or fills do exist. Soils or fills meeting all four of the following provisions shall be considered to be expansive, except that tests to sho with Items 1, 2 and 3 shall not be required if the test prescribed in Item 4 is conducted: 163 pdf_text
6 6. Add new Section E104.2.1.1 to read: "E104.2.1.1 Overlap. At least one unit required to provide mobility features complying with Section 1107.5.1.1 or 1107.6.1.1 shall be used minimum number of units required to provide accessible communication features complying with Section E104.2.1. 220 pdf_text
6 6. Delete Section 412.4 and its subsections. 32 pdf_text
6 6. Delete the first sentence of Section 1605.3.1.2. 146 pdf_text
6 6. In Group R-2 occupancies where the building is equipped throughout with an automatic sp in accordance with Section 903.3.1.1 or 903.3.1.2 and dead-end corridors do not exceed 20 fe the separation distance shall be not less than 15 feet (4572 mm)." 91 pdf_text
6 6. Fire pumps." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 8) 27 pdf_text
6 6. Insert the following standard under ASSE: "ANSI/ASSE A10.8–2011: Scaffolding Safety Requirements" 216 pdf_text
6 6,0 S1 UL UL 42 pdf_text
6 6. Revise item 25 in Section 603.1 to read: "25. Materials exposed within plenums complying with the Chicago Mechanical Code and Chicago Electric 50 pdf_text
6 6. Delete Section D102.2.5. 218 pdf_text
6 6. Revise Section 403.2.3 by replacing "420 feet (128 m)" with "400 feet (122 m)." 24 pdf_text
6 6. Revise Section 3002.9 to read: "3002.9 Plumbing, gas and mechanical systems. Plumbing, fuel gas and mechanical systems, other than elevator equipment, shall not be located in an elevator hoistw Exceptions: 198 pdf_text
6 6. Revise Section 1810.3.1.1 by deleting "approved." 170 pdf_text
6 6. Delete both exceptions to Section 707.5.1. 58 pdf_text
6 6. Delete Section 1013.5. 98 pdf_text
6 6. Revise Section 1406.11 and its subsections to read: "1406.11 Alternate conditions. Where approved by the building official, MCM and MCM systems shall not be required to comply with Sections 140 132 pdf_text
6 6. Revise Section 1011.5.3 to read: "1011.5.3 Winder treads. Winder treads are not permitted in means of egress stairways. Exceptions: 96 pdf_text
6 6. Revise Section 1805.2.1 by replacing "approved" with "equivalent." 165 pdf_text
6 6. Revise the exception to Section 912.4 by deleting "approved by the fire code official." 81 pdf_text
6 6. Revise Section 1408.11 and its subsections to read: "1408.11 Alternate conditions. Where approved by the building official, HPL and HPL systems shall not be required to comply with Section 1408.1 that such systems comply with Section 1408.11.1. 133 pdf_text
6 6. Revise Section 916.10 to read: "916.10 Fire alarm system connections. Gas sensors and gas detection systems shall not be connected to fire alarm systems unless approved by the fire code connected in accordance with the fire alarm equipment manufacturer’s instructions." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 37) 82 pdf_text
6 6,0 S1 UL UL UL UL 41 pdf_text
6 6. Revise the exception to Section 1705.3, items 1 and 2, to read: "1. Isolated spread concrete footings of buildings four stories or less above grade plane that are fully suppor rock. 157 pdf_text
6 6. Delete Section 1808.6.2. 169 pdf_text
6 6,0 S1 UL UL UL UL UL 41 pdf_text
6 6. Revise note d to Table 307.1(2) to delete "approved." 20 pdf_text
6 6. Delete Section 915.1.6. 82 pdf_text
6 6. Revise Section 1107.5.2.2 to read: "1107.5.2.2 Type B units. In structures with four or more dwelling units or sleeping units, every dwelling unit and sleeping unit shall be a Type 113 pdf_text
6 6. Delete Section 2308.3.1.1. 185 pdf_text
6 6. Where the most remote portion of a nonsprinklered floor or story is more than 150 feet (45 720 m 72 pdf_text
6 6. Revise Section 910.3.2 by adding the following sentence at the end: "Vents shall be spaced no greater than 100 feet (30.5 m) apart, on center." 79 pdf_text
6 6. Revise Section 905.3.4.1 by deleting "approved." 72 pdf_text
6 6. Revise Table 1004.5 by replacing "Kitchens, commercial" with "Kitchens and service areas, commercial." 85 pdf_text
6 (cont. 2) equired door-opening o forces. The actual force required to open exit doors when the system is in the smoke control mode shall be in with Section 1010.1.3. Opening and closing forces for other doors shall be determined by standard engineerin the resolution of forces and reactions. The calculated force to set a side-hinged, swinging door in motion shal determined by: F = Fdc + K(WAΔP)/2(W-d) (Equation S-1) where: A = Door area, square feet (m2). d = Distance from door handle to latch edge of door, feet (m). F = Total door opening force, pounds (N). 222 pdf_text
6.1 6.1. Revise Section 1006.2.2.2 by replacing "equal to one-half" with "equal to not less than one-half." 88 pdf_text
6.1 6.1. Revise Section 1011.5.5 by deleting the second sentence. 96 pdf_text
6.1 6.1. Minimum clearances have been provided as required by Section 13.2.3 ASCE/SE 160 pdf_text
6.1 6.1. The level is either: 89 pdf_text
6.1.1 6.1.1. A story not more than one story above or below the first story above grade pla 89 pdf_text
6.1.2 6.1.2. A mezzanine in accordance with Section 505.2. 89 pdf_text
6.1.3 6.1.3. A loft in accordance with Section 1207.5. 89 pdf_text
6.2 6.2. The floor area of the level does not exceed: 89 pdf_text
6.2 6.2. A nominal clearance of not less than 3 inches (76 mm) has been be provided bet protection sprinkler system drops and sprigs and: structural members not used collectiv independently to support the sprinklers; equipment attached to the building structure; a systems’ piping. Where flexible sprinkler hose fittings are used, special inspection of minimum clearances is not requir 160 pdf_text
6.2.1 6.2.1. 1,600 square feet (148.6 m2). 89 pdf_text
6.2.2 6.2.2. 2,000 square feet (185.8 m2) where the building is protected throughout with an sprinkler system. 89 pdf_text
6.3 6.3. The dwelling unit has an exit door that discharges directly to the exterior at the level of e 89 pdf_text
60 60. Delete the definition of "covered mall building" (and related definitions). 7 pdf_text
602.4.3 602.4.3 Exterior structural members. Where a fire separation distance of 20 feet (6096 mm) or more is provided, wood columns and arches heavy timber sizes complying with Section 2304.11 shall be permitted to be used externally." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 21; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 9) 49 pdf_text
604.1 604.1 Allowable materials. Combustible materials shall be permitted in the exterior walls of buildings of Type III or IV construction where com materials in the same application are permitted in the exterior walls of buildings of Type I or II construction by Secti 50 pdf_text
605.1 605.1 General. In all buildings, basement construction shall comply with the requirements of Sections 605.2 through 605.4. 50 pdf_text
605.2 605.2 Basement columns and bearing walls. In buildings of Type III or V construction with three or more stories above grade plane, all basement columns and b bearing walls shall be of noncombustible material or of heavy timber construction. 50 pdf_text
605.3 605.3 Multiple basement stories. In buildings with more than one basement story, the floor construction separating the highest basement from the first grade plane and all construction below that level shall be of Type IA construction. 50 pdf_text
605.4 605.4 Floor construction. Except in buildings of Group R-5 occupancy, floor construction over basements shall have a fire-resistance rating of hour." CHAPTER 14B-7 FIRE AND SMOKE PROTECTION FEATURES 50 pdf_text
61 61. Revise the definition of "cryogenic fluid" to read: "CRYOGENIC FLUID. As defined in Chapter 2 of the Chicago Fire Prevention Code." 7 pdf_text
62 62. Insert the following definition: "CURB RAMP (for Chapter 11). A ramp that cuts through or is built up to the curb. Curb ramps can be perpendic or a combination of perpendicular and parallel ramps." 7 pdf_text
62.1 62.1–2016: Ventilation for Acceptable Indoor Air Quality" 216 pdf_text
63 63. Revise the definition of "dangerous" to read: "DANGEROUS. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 7 pdf_text
64 64. Revise the definition of "day box" to read: "DAY BOX. As defined in Chapter 2 of the Chicago Fire Prevention Code." 7 pdf_text
65 65 S UL I NS b 37 pdf_text
65 65. Insert the following definition: "DECK. An open, unroofed and uncovered floor structure, other than an occupiable rooftop, designed or used for m incidental occupancy, which may or may not include an exterior means of egress." 7 pdf_text
66 66. Revise the definition of "decorative glass" to read: "DECORATIVE GLAZING. A carved, leaded or Dalle glass or glazing material whose purpose is decorative or ar functional; whose coloring, texture or other design qualities or components cannot be removed without destroying th material and whose surface, or assembly into which it is incorporated, is divided into segments." 7 pdf_text
67 67. Revise the definition of "deferred submittal" to read: "DEFERRED SUBMITTAL. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisio 7 pdf_text
68 68. Revise the definition of "deflagration" to read: "DEFLAGRATION. As defined in Chapter 2 of the Chicago Fire Prevention Code." 7 pdf_text
69 69. Delete the definition of "design flood." 7 pdf_text
7 7. Revise item 1 of Section 2603.4.1.5 to read: "1. The roof assembly is separated from the interior of the building by wood structural panel sheathing not l inch (11.9 mm) in thickness bonded with exterior glue, with edges supported by blocking, tongue-and-groove approved type of edge support or material." 192 pdf_text
7 7. Revise Section 1609.3.1 to read: "1609.3.1 Wind speed conversion. Where required, the basic design wind speeds of Section 1609.3 shall be converted to allowable stress design wind s using Equation 16-33." 149 pdf_text
7 7. Suitability of deep foundation materials for the intended environment. 164 pdf_text
7 7. Revise Section E104.2.2 to read: "E104.2.2 Group I-3. In Group I-3 occupancies at least 3 percent, but no fewer than one of the total number of general holding cells and ge cells equipped with audible emergency alarm systems and permanently installed telephones within the cell, shall com Section E104.2.4. Cells shall be provided in each classification level." 220 pdf_text
7 7. Revise Section 905.3.6 to read: "905.3.6 Helistops and heliports. Buildings with a rooftop helistop or heliport shall be equipped with a Class I or III standpipe system extended to the which the helistop or heliport is located." 72 pdf_text
7 7. Revise Section 2303.1.11 to read: "2303.1.11 Structural log members. Stress grading of structural log members of nonrectangular shape, as typically used in log buildings, shall be in accor ASTM D3957. Such structural log members shall be identified by the grade mark of an approved agency. In lieu of a on the material, a certificate of inspection as to species and grade issued by a lumber grading or inspection agency m requirements of this section shall be permitted." 183 pdf_text
7 7. Delete Section 1406.11.2 and its subsections. 132 pdf_text
7 7. Revise Section 714.5.1.1 by deleting "approved." Revise Section 714.5.1.2 by replacing "an approved" with "a." 60 pdf_text
7 7. Revise Section 1810.3.1.3 to read: "1810.3.1.3 Mislocation. The foundation or superstructure shall be designed to resist the effects of the mislocation of any deep foundation ele (individual pier or centroid of a group) by not less than 3 inches (76 mm) and not less than any larger tolerance ident report of geotechnical investigations. To resist the effects of mislocation, compressive overload of deep foundation e percent of the allowable design load shall be permitted." 170 pdf_text
7 7. Revise Table 1004.5 by deleting the row for "Mall buildings-covered and open." 85 pdf_text
7 7. Delete the last sentence of Section 406.4. 29 pdf_text
7 7. Revise Section 1704.3.1, item 4, by deleting "1705.11." 156 pdf_text
7 7. Power and lighting for the fire command center required by Section 403.4.6. 26 pdf_text
7 7. Revise Section 915.2.3 to read: "915.2.3 Group E and I-4 occupancies. Carbon monoxide detectors shall be installed in classrooms in Group E and I-4 occupancies. Carbon monoxide alarm be automatically transmitted to an on-site location that is staffed by school personnel. Exception: Carbon monoxide alarm signals shall not be required to be automatically transmitted to an on- sit is staffed by school personnel in Group E or I-4 occupancies with an occupant load of 30 or less." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 36) 82 pdf_text
7 7. Revise Section 1006.2.2.3 by deleting "approved." 88 pdf_text
7 7. Revise Section 912.4.1 to read: "912.4.1 Breakaway fire department connection caps. The fire code official is authorized to require breakaway caps on fire department connections for water-based fire pro systems." 81 pdf_text
7 7. Revise the title of Section 1507.4.5 to "Underlayment." 137 pdf_text
7 7. Add a new item 4 in Section 903.2.1.3 to read: "4. The Group A-3 occupancy contains one or more exhibition areas exceeding 5,000 square feet (464 m 2 ) 68 pdf_text
7 7. Delete Section 1408.11.2 and its subsections. 133 pdf_text
7 7. Delete Section 1605.3.2 and its subsections. 146 pdf_text
7 7. Revise Section 1107.5.5 to read: "1107.5.5 Group I-3. Accessible units and units with communication features shall be provided in Group I-3 occupancies in accordance wi 113 pdf_text
7 7. Add new Sections 1109.12.1.1 and 1109.12.1.2 to read: 118 pdf_text
7 7. Delete Figure 705.7. 54 pdf_text
7 7. Delete Table 1029.6.2. 105 pdf_text
7 7. Revise Section 1805.2.2 by replacing "approved" with "equivalent." 165 pdf_text
7 7. Delete the exception to Section 1803.5.4. 163 pdf_text
7 7. Revise Section 910.4.1 by deleting "approved." 79 pdf_text
7 7. Revise Section 1013.6 and its subsections to read: "1013.6 Internally illuminated exit signs. Internally illuminated exit signs shall comply with Sections 1013.6.1 through 1013.6.3. 98 pdf_text
7 7. Revise note e to Table 307.1(2) to delete "approved." 20 pdf_text
7 7. Revise Section 306.3 to insert, alphabetically: "Water pumping stations." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 3) 20 pdf_text
7 7. Revise Section 1809.13 by replacing "Seismic Design Category D, E or F" with "Seismic Design Category D." 170 pdf_text
7 7. Where there is no occupiable rooftop above and the highest roof plane is provided with co insulation installed entirely above and not exceeding 12 inches (305 mm) in height above the s deck and required parapet walls, building height may be measured to the highest point of the st deck. 17 pdf_text
7 7. Revise row 22 of Table 1607.1 to read: 147 pdf_text
7 7. Revise the first sentence of Section 3007.6.5 to read: "A pictorial symbol of a standardized design designating which elevators are fire service access elevators shall be ins side of the hoistway door frame." 200 pdf_text
7 7. Benches in outdoor locations." 119 pdf_text
7 7. Housing intended primarily for students through the undergraduate level, including apartments, do fraternity and sorority houses. 83 pdf_text
7 7. Revise Section 1808.6.3 to read: "1808.6.3 Removal of expansive soil or fill. Where expansive soil or fill is removed, the soil shall be removed to a depth sufficient to ensure a constant moisture remaining soil or fill. Newly placed fill material shall not contain expansive soils or fill and shall comply with Sectio 169 pdf_text
7 7. Controls for unlocking interior exit stairway doors simultaneously. 80 pdf_text
7 7. Delete Section 1603.1.7. 144 pdf_text
7 7. Revise Table 1807.1.6.3(3) by: a. Deleting the columns for 30 and 45 psf per foot; b. Deleting note e. 168 pdf_text
7 7. Panel doors shall be completely removable from the hinges. 79 pdf_text
7 7. Revise Section 907.2.2 by replacing "500" with "300." 74 pdf_text
7 7. Revise Section 707.9 to read: "707.9 Voids at intersections. The voids created at the intersection of a fire barrier and a nonfire-resistance-rated roof assembly or a nonfire- resist exterior wall assembly shall be filled. The material or system used to fill the void shall be securely installed in or on for its entire length so as not to dislodge, loosen or otherwise impair its ability to accommodate expected building m to retard the passage of fire and hot gases." (Amend Coun. J. 10-7-20, p. 21791, Art. II, § 11) 58 pdf_text
7 7. Delete Section 2308.3.1.2. 185 pdf_text
7 7. Delete item 5 in Section 1020.5.1. 102 pdf_text
7 7. Mercantile (see Section 309): Group M. 19 pdf_text
7 7 feet (2134 mm). 112 pdf_text
7 7. Revise Section 412.5 by replacing "Section 416" with "the Chicago Fire Prevention Code." (Amend Coun. J. 10-7-20, p. 21791, Art. II, § 5) 32 pdf_text
7 7. Revise item 5 in Section 420.8 by deleting "Section 505 of." 34 pdf_text
7 7. Weather-protected entries not more than 12 feet (3658 mm) high and not more than 50 square feet area. 219 pdf_text
7 7. Add a new item 27 to Section 603.1 to read: "27. Exterior fiber-reinforced polymer as permitted by Section 2613.5." 50 pdf_text
7 7. An accessible route between stories is not required where Type B units are exempted by S 113 pdf_text
7 7. Revise Table 403.2.4 by replacing "420 feet" with "400 feet." 24 pdf_text
7 7. Delete exceptions 2, 3 and 4 to Section 717.5.2. 62 pdf_text
7 7. Revise item 1 in Section 706.5.1 to read: "1. The exterior walls on both sides of the fire wall shall be of noncombustible construction and have a 1-ho resistance rating with 3/4-hour protection where opening protection is required by Section 705.8. The fire-re of the exterior wall shall extend not less than 4 feet (1220 mm) on each side of the intersection of the fire wal wall. Exterior wall intersections at fire walls that form an angle equal to or greater than 180 degrees (3.14 rad exterior wall protection." 57 pdf_text
7 7. Revise Section 1404.3.4 to read: "1404.3.4 Vented cladding. For the purposes of this section, vented cladding shall include the following: 129 pdf_text
7 7. Revise Section D102.2.6 to read: "D102.2.6 Exterior walls. Exterior load-bearing walls of Type IIA buildings and, where permitted, Type IIB buildings shall have a fire- resista hours or more where such walls have a fire separation distance of 30 feet (9144 mm) or less. Where allowed by Sect exterior nonload-bearing walls of Type IIB buildings located within 30 feet (9144 mm) of an abutting property line o property line shall have fire-resistance ratings as required by Table 601, but not less than 1 hour. Exterior walls locat 218 pdf_text
7 7. Revise the definition of "adhered masonry veneer" to read: "ADHERED MASONRY VENEER. Veneer secured and supported through the adhesion of a bonding material ap backing." 4 pdf_text
7 7. Delete item 8 in Section 716.2.6.6. 62 pdf_text
7 7. Replace each occurrence of "International Mechanical Code" with "Chicago Mechanical Code." 2 pdf_text
7 7. Replace Table 504.4 as shown: TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE a, b 37 pdf_text
7 7. Revise Section 308.4.1 to read: "308.4.1 Condition 1. This occupancy condition shall include buildings in which free movement is allowed from sleeping areas, and other s access or occupancy is permitted, to the exterior via means of egress without restraint. A Condition 1 facility is perm constructed in accordance with requirements for a Group R occupancy where approved by the fire code official." 21 pdf_text
7 7. Delete Section 1023.11 and its subsections. (Amend Coun. J. 6-25-21, p. 32180, Art. II, § 19) 103 pdf_text
7 7. Revise the exception to Section 1705.4, item 1, by deleting "where they are part of a structure classified as Risk or III." 158 pdf_text
7 7. The third story above grade plane within a dwelling unit provided all the following criteria are me 89 pdf_text
7 7. Revise Section 1010.1.3 to read: "1010.1.3 Door opening force. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds force for pushing or pulling open exterior hinged doors and gates shall not exceed 8.5 pounds (38 N). These forces d the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other s as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door motion when subjected to a 30-pound (133 N) force. The door shall swing to a full-open position when subjected to N) force. Exceptions: 93 pdf_text
7 7. Inside the main entrance of each dwelling unit and sleeping unit. 77 pdf_text
7 7. Revise Section 1510.6.2 to read: "1510.6.2 Type I, II, III or IV construction. Regardless of the requirements in Section 1510.6, mechanical equipment screens that are located on the roof decks o Type I, II, III or IV construction shall be permitted to be constructed of combustible materials in accordance with the limitation: the fire separation distance shall be not less than 20 feet (6096 mm) and the height of the mechanical equi above the roof deck shall not exceed 4 feet (1219 mm) as measured to the highest point on the mechanical equipmen 139 pdf_text
7 7. Delete the following standards under ASTM: B101–12; D5019–07a; D7254–15; E90–09; E492–09; E1886–13A; and E2599–15. 216 pdf_text
7 7. Revise Section 1011.5.5.3 to read: "1011.5.5.3 Riser profile. Risers shall be solid and vertical or sloped under the tread above from the underside of the nosing above at an angle 96 pdf_text
7 7. Replace Table 508.4 as shown: TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS) f OCCUPANCY A, E I-1 a, I-3, I-4 I-2 R a F-2, S-2 b, U B e, M F-1, S-1 H-1 H-2 H-3, 45 pdf_text
7 7. Revise Table 1202.3 by deleting all rows except for Climate Zone 5. 121 pdf_text
7 7. Delete Section 1505.5. 136 pdf_text
7 7. Revise Section 506.3.1 to read: "506.3.1 Minimum percentage of perimeter. To qualify for an area factor increase based on frontage, a building shall have not less than 25 percent of its perimete way, court or yard. Such court or yard shall be either on the same lot or dedicated for public use and shall have direc less than 20 feet (6096 mm) wide, from a public way." 43 pdf_text
7 7. Revise Section 1806.3.3 by replacing "Table 1806.2" with "Table 1806.2(1)." (Amend Coun. J. 10-7-20, p. 21791, Art. II, § 29) 168 pdf_text
7 7. Revise Section 1403.9 by replacing "approved quality control agency" with "approved agency." 129 pdf_text
7 7. Revise Section 2113.11.3.4 by deleting "approved." 180 pdf_text
7 7. Delete Section 2702.2.3. 196 pdf_text
7 7. Revise Section 2304.11.1.2 to read: "2304.11.1.2 Floor framing. Minimum dimensions of floor framing shall be in accordance with Table 2304.11. Wall plate boxes or hangers shall where wood beams, girders or trusses rest on masonry or concrete walls. Where intermediate beams are used to supp they shall rest on top of girders, or shall be supported by a metal hanger into which the ends of the beams shall be clo Where traditional heavy timber detailing is used, these connections shall be permitted to be supported by ledgers or b fastened to the sides of the girders." 184 pdf_text
7 7. Delete Section 1604.10. (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 72) 146 pdf_text
7 7. Add new Sections 3002.10 and 3002.11 to read: "3002.10 Electrical, fire protection and communications wiring. Electrical, fire protection and communications wiring not essential to the elevator shall not be located in an elevator enclosure. 198 pdf_text
7 7. Revise Section 1009.8.1 to read: "1009.8.1 System requirements. Two-way communication systems shall provide communication between each required location and the fire comman central control point location acceptable to the fire code official. Where the central control point is not a constantly at location, a two-way communication system shall have a timed automatic telephone dial-out capability to a 24/7 moni The two-way communication system shall include both audible and visible signals. If a handset is provided, the hand be at least 29 inches (735 mm) long." 92 pdf_text
7 7. Wind loads determined in accordance with Chapter 28 of ASCE 7 shall only be allowed fo containing only Group F, S or U occupancies. 148 pdf_text
7.1 7.1. Delete Section 3007.7. 200 pdf_text
7.1 7.1. The building is equipped throughout with an automatic sprinkler system in accordance w 89 pdf_text
7.2 7.2. The floor area of the story does not exceed 1,600 square feet (148.6 m2). 90 pdf_text
7.3 7.3. The dwelling unit has an exit that discharges directly to the exterior at the level of exit dis 90 pdf_text
70 70% Unprotected, Sprinklered (UP, S) i No Limi Protected (P) No Limi 55 pdf_text
70 70. Delete the definition of "design flood elevation." 7 pdf_text
705.2.1 705.2.1 Types I and II construction. Projections from walls of Type I or II construction shall be of materials allowed by Table 705.2.1 . Projection the table shall conform to the type of construction and fire-resistance rating required for the building to whic attached. 52 pdf_text
705.2.2 705.2.2 Type III, IV or V construction. Projections from walls of Type III, IV or V construction shall be of noncombustible materials or combustible allowed by Table 705.2.1 or Table 705.2.2. Projections not listed in the table shall conform to the type of con fire-resistance rating required for the building to which they are attached. 52 pdf_text
705.2.3 705.2.3 Combustible projections. Decks, exterior balconies, exterior exit stairways, porches, and similar projections of combustible constructio exceed 50 percent of the building’s perimeter on each floor." 52 pdf_text
705.3 705.3. exception 1, are not required to comply with Section 705.8.6. 56 pdf_text
71 71. Revise the definition of "detached building" to read: "DETACHED BUILDING. A separate single-story building, without a basement or crawl space, used for the stora hazardous materials and located an acceptable distance from all other structures." 7 pdf_text
712.1.8 712.1.8 or 712.1.10 through 712.1.15 shall be permitted if the opening complies with either of the following items: 59 pdf_text
716.2.2.1 716.2.2.1. The door assembly from the vestibule to the stairway or ramp shall not have less than a 20- protection rating and shall meet the requirements for a smoke door assembly in accordance with Secti The door shall be installed in accordance with NFPA 105. S101.20.4.2 Vestibule ventilation. The vestibule shall be supplied with not less than one air change per minute and the exhaust shall be n 228 pdf_text
716.2.2.1 716.2.2.1 with a fire protection rating of not less than 20 minutes. 90 pdf_text
716.2.2.1 716.2.2.1 with a fire protection rating of not less than 20 minutes. Doors shall be self-closing and self- Only one attached private garage or carport shall be allowed per building. 29 pdf_text
72 72. Revise the definition of "detonation" to read: "DETONATION. As defined in Chapter 2 of the Chicago Fire Prevention Code." 7 pdf_text
73 73. Insert the following definition: "DISABILITY (for Chapter 11). A physical or mental impairment that substantially limits one or more major life a record or history of such an impairment; or regarded as having such an impairment." 7 pdf_text
74 74. Revise the definition of "dormitory" to read: "DORMITORY. A space in a building where group sleeping accommodations are provided in one room, or in a seri associated rooms, for persons not members of the same family group or household." 7 pdf_text
75 75. Delete the definition of "dry floodproofing." 8 pdf_text
750 750 square feet (69.7 m 2 ), where the aggregate gross floor area of such rooms or spaces within the s does not exceed 10 percent of the gross floor area of the suite or story, the occupant load shall be det applying the occupant load factor in Table 1004.5 that is applicable to the predominant function of ad within the same suite and same story which are not used for assembly-type functions. 87 pdf_text
76 76. Delete the definition of "dwelling." 8 pdf_text
77 77. Insert the following definition: "EAVE HEIGHT. The vertical distance from the ground surface adjacent to the building to the roof eave line at a p If the vertical distance varies along the wall, eave height shall be the average height." 8 pdf_text
78 78. Insert the following definition: "ELEMENT (for Chapter 11). An architectural, mechanical (including plumbing) or electrical component of a buil space, site, or public right-of-way." 8 pdf_text
79 79. Delete the definition of "emergency escape and rescue opening." 8 pdf_text
8 8. Revise Section 1808.6.4 to read: "1808.6.4 Stabilization. Where the active zone of expansive soils or fill is stabilized in lieu of designing foundations in accordance with Secti 169 pdf_text
8 8. Revise Section 1403.10 by replacing "approved quality control agency" with "approved agency." 129 pdf_text
8 8. Revise Section 905.3.7 by deleting "Chapter 36 of." 72 pdf_text
8 8. Delete Section 1705.4.1. 158 pdf_text
8 8. Add a new Section E111 to read: "E111. PUBLIC WAY E111.1 General. Construction in the public way shall comply with regulations adopted by the Commissioner of Transportation." 220 pdf_text
8 8. Add a new Section 1107.5.5.1.1 to read: "1107.5.5.1.1 Beds. In sleeping units having more than 25 beds, at least 5 percent of the beds shall be accessible." 113 pdf_text
8 8. Delete Section 1406.11.3 and its subsections. 132 pdf_text
8 8. Delete Section 1704.3.3. 156 pdf_text
8 8,000 N S1 UL UL 42 pdf_text
8 8. Delete Section 420.8.1. 34 pdf_text
8 8. Revise Section 406.4.3 to read: "406.4.3 Ramps. Vehicle ramps shall not be considered as vertical components of the means of egress connecting more than one story designated pedestrian paths are marked. Vehicle ramps that are utilized for vertical egress as well as for parking shall slope of 1:15 (6.67 percent)." 29 pdf_text
8 8. Wind loads determined in accordance with Section 1609.6. The wind speeds in Section 1609.3 are basic design wind speeds, V. Allowable stress design wind speeds, Vasd, fro 149 pdf_text
8 8. Revise Table 1004.5 by revising the entries under "Mercantile" to read: "Mercantile | First story above grade plane | 30 net Basement sales floor | 30 net Other floors | 60 net Storage, stock, shipping areas | 300 gross" 85 pdf_text
8 8. Add a new Section 1109.13.1 to read: "1109.13.1 Operable windows. Where operable windows are provided for operation by occupants, at least one operable window in each room shall and each required operable window shall be accessible. Exceptions: 119 pdf_text
8 8. Revise Section 1408.13 to read: "1408.13 Foam plastic insulation. HPL systems containing foam plastic insulation shall comply with the requirements of Section 2603." 133 pdf_text
8 8. Revise Section 1805.2.2.1 to read: "1805.2.2.1 Surface preparation of walls. Prior to application of dampproofing materials on concrete walls, holes and recesses resulting from the removal of fo be sealed with a bituminous material or other equivalent methods or materials. Unit masonry walls shall be parged o surface below ground level with not less than 3/8 inch (9.5 mm) of Portland cement mortar. The parging shall be cov footing. Exception: Parging of unit masonry walls is not required where a material is intended for direct application t masonry." 165 pdf_text
8 8. Revise Section 912.4.2 to read: "912.4.2 Clear space around connections. A working space with a radius of 5 feet (1524 mm) shall be provided and maintained in front of wall-mounted fire d connections and around the circumference of free-standing fire department connections, except as otherwise required by the fire code official." 81 pdf_text
8 8. Insert the following standards under ASTM: "A48/A48M–03(2016): Standard Specification for Gray Iron Castings" "C1549–2016: Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Po Reflectometer" "D2974–14: Standard Test Methods for Moisture, Ash, and Organic Matter of Peat and Other Organic Soils" "D4792/D4792M–13(2019): Standard Test Method for Potential Expansion of Aggregates from Hydration Reactions 216 pdf_text
8 8. Revise the exception to Section 1010.1.4.1.2, item 4, by replacing "in an approved location and clearly identified sight of the revolving door." 93 pdf_text
8 8. Revise Section 1803.5.5 to read: "1803.5.5 Deep foundations. Where deep foundations will be used, a geotechnical investigation shall be conducted and shall include all of the foll applicable: 163 pdf_text
8 8. Parking garages exceeding 5,000 square feet (465 m2). 77 pdf_text
8 8. Revise the Description of V in Equation 16-33 to read: "V = Basic design wind speed determined from Section 1609.3." 149 pdf_text
8 8. Public utility structures. 83 pdf_text
8 8. Revise Section 1510.6.3 to read: "1510.6.3 Type V construction. The height of mechanical equipment screens located on the roof decks of buildings of Type V construction, as meas grade plane to the highest point on the mechanical equipment screen, shall not exceed the maximum building height the building by other provisions of this code." 139 pdf_text
8 8. Delete Section 2304.11.2.1. 184 pdf_text
8 8. Replace each occurrence of "International Energy Conservation Code" with "Chicago Energy Conservation Cod 2 pdf_text
8 8. Add a new Section 1020.7 to read: "1020.7 Toilet rooms. Separation shall not be required between a toilet room and a fire-resistance-rated corridor where the toilet room meet following criteria: 102 pdf_text
8 8. Revise Section 1810.3.2.1.1 by replacing "Seismic Design Category C, D, E or F" with "Seismic Design Categor 170 pdf_text
8 8. Revise Section 508.4.3, including the exception, to read: "508.4.3 Allowable building height and number of stories above grade plane. Each separated occupancy shall comply with the building height limitations and story above grade plane limitations type of construction of the building in accordance with Section 503.1." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 18; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 8; Amend Coun. J. 6-25-21, II, § 7; Amend Coun. J. 1-26-22, p. 43756, Art. II, § 5; Amend Coun. J. 1-24-24, p. 8634, Art. IV, § 1) 46 pdf_text
8 8. Where a stairway door locking system is used, the required release switch shall be clearly marked. 80 pdf_text
8 8. Revise Section 308.5.1 to read: "308.5.1 Classification as Group E-2. A child day care facility that provides care for less than 30 children under 2 years of age, where the rooms in which t cared for are located on a level of exit discharge serving such rooms, shall be classified as Group E-2." 21 pdf_text
8 8. Revise the exception to Section 403.3 to read: "Exception: An automatic sprinkler system shall not be required in parking facilities accordance with Section 406.9. 25 pdf_text
8 8. Revise Section 603.1.2 to read: "603.1.2 Piping. The use of combustible piping materials shall be permitted where installed in accordance with the limitations of Sect Chicago Mechanical Code and the Chicago Plumbing Code." 50 pdf_text
8 8. Revise Section 2702.2.4 to read: "2702.2.4 Voice communication systems. Emergency power shall be provided for voice communication systems as required in Section 907.2.12.2. The system capable of powering the required load for a duration of not less than 24 hours, as required in NFPA 72." 196 pdf_text
8 8. Revise Section 716.2.9.1 by deleting "approved and." 62 pdf_text
8 8. Revise the first sentence of Section 1404.4 to read: "Flashing, including end dams, shall be installed in such a manner so as to prevent moisture from entering the wall o that moisture to the exterior." 129 pdf_text
8 8. Greenhouses less than 15 feet (4572 mm) high and less than 400 square feet (37.2 m2) in area. 219 pdf_text
8 8. Revise exception 5 to Section 717.5.2 to read: "5. Fire dampers are not required in kitchen and clothes dryer exhaust systems." 62 pdf_text
8 8. Revise Section 506.3.2 to read: "506.3.2 Minimum frontage distance. To qualify for an area factor increase based on frontage, the public way, court or yard adjacent to the building perime a minimum distance (W) of 20 feet (6096 mm) measured at right angles from the building face to any of the followin 43 pdf_text
8 8. Residential (see Section 310): Groups R-1, R-2, R-3, R-4 and R-5. 19 pdf_text
8 8. Designation of bearing stratum or strata. 164 pdf_text
8 8. Sump pumps required by Section 403.4.9.3." 26 pdf_text
8 8. Revise Table 2308.4.1.1(1) by deleting the columns for snow loads of 50 psf and 70 psf and the heading rows "G SNOW LOAD (psf)" and "30". 185 pdf_text
8 8. Revise Section 2303.2.2 by replacing "approved" with "acceptable." 183 pdf_text
8 8. Revise Section 1009.10 by deleting "approved." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 43) 92 pdf_text
8 8. Delete Section 1603.1.9. 144 pdf_text
8 8. Add new Section D102.2.6.1 to read: "D102.2.6.1 Exterior walls of Type IIB, VA and VB construction. Where allowed by Section D105, exterior walls of buildings of Type IIB, VA and VB construction shall be located t separation distance of not less than 3 feet (914 mm). Where the fire separation distance is 6 feet (1829 mm) or less, wall shall have a fire-resistance rating of 1 hour or greater." 218 pdf_text
8 8. Revise Section 1505.10 to read: "1505.10 Vegetative roofs, roof gardens and landscaped roofs. Vegetative roofs, roof gardens and landscaped roofs shall comply with Sections 1507.16 and 1514." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 67) 136 pdf_text
8 8. Revise item 2 in Section 706.5.1 by replacing "lot line" with "property line." 57 pdf_text
8 8. Delete Section 2603.4.1.6. 192 pdf_text
8 8. Revise note a to Table 1202.3 to read: "a. Contributes to, but does not supersede, thermal resistance requirements for attic and roof assemblies in the Chic Conservation Code." 121 pdf_text
8 8. Delete item 3 in Section 903.2.1.4. 68 pdf_text
8 8. Revise the exception to Section 907.2.2 to read: "Exception: Manual fire alarm boxes are not required where the building is equipped throughout with an automatic system installed in accordance with Section 903.3.1.1 and the occupant notification appliances will activate in accord 74 pdf_text
8 8. Delete item 2 in Section 3007.8. 200 pdf_text
8 8. Revise Table 1807.1.6.3(4) by: a. Deleting the columns for 30 and 45 psf per foot; b. Deleting note e. 168 pdf_text
8 8. Sprinkler valve and waterflow detector display panels. 80 pdf_text
8 8. Delete Table 705.8. 54 pdf_text
8 8. Revise row 25 of Table 1607.1 to read: 147 pdf_text
8 8. Delete the definition of "adobe construction" (and related definitions). 4 pdf_text
8 8. Revise note g to Table 307.1(2) to delete "approved." 20 pdf_text
8 8. Revise exception 3 to Section 714.5.2 by replacing "any size or type" with "any size or type allowed by the Chic Code." 60 pdf_text
8 8. Revise Section 1507.5.6 by deleting "approved." 137 pdf_text
8 8. Revise Section 1006.2.2.4 by replacing "2 1/2 years of age or less" with "less than 2 years of age." 88 pdf_text
8 8. The third story above grade plane within a dwelling unit provided that all of the following criteria 90 pdf_text
8.1 8.1. Add new Sections 406.4.4 through 406.4.6 to read: "406.4.4 Construction. Public parking garages shall be of Type I, II, or IV construction. Public parking garages of Type IIB or IV constructi be permitted in single-story buildings. Floors supporting motor vehicles shall have a fire-resistance rating of at least 29 pdf_text
8.1 8.1. Revise note d to Table 2308.4.1.1(1) by replacing "an approved framing anchor" with "a framing anchor." 185 pdf_text
8.1 8.1. The building does not contain more than three stories above grade plane. 90 pdf_text
8.2 8.2. The building does not contain more than three dwelling units. 90 pdf_text
8.2 8.2. Delete note e to Table 2308.4.1.1(1). 185 pdf_text
8.3 8.3. The net floor area of the story does not exceed 800 square feet (74.3 m2). 90 pdf_text
8.4 8.4. Each habitable space on the story shall have a window with a minimum net clear openin feet (0.53 m2), the bottom of which is not more than 44 inches (1118 mm) above the floor. 90 pdf_text
8.5 8.5. Each room within the dwelling unit used for sleeping purposes shall be provided with so not less than 1 3/4 inches (45 mm) in thickness in a rabbeted frame, or doors in compliance wi 90 pdf_text
8.6 8.6. In addition to an interior exit access stairway, the second story above grade plane shall h second interior exit access stairway leading directly to an exit door that discharges to the exteri of exit discharge or access to an exterior means of egress leading directly to grade. 90 pdf_text
8.7 8.7. Either of the following shall be provided at the third story above grade plane: 90 pdf_text
8.7.1 8.7.1. The exit access stairway is enclosed with construction providing a fire-resistan least one hour and a door meeting criterion 8.5. 90 pdf_text
8.7.2 8.7.2. An exterior balcony is provided with a depth of at least 3 feet (914 mm). 90 pdf_text
80 80. Delete the definition of "emergency voice/alarm communications." 8 pdf_text
803.1.1.1 803.1.1.1, UL 1040 or UL 1715. Such testing shall be performed with the MCM in the maximum thickness in use. The MCM system shall include seams, joints and other typical details used in the installation and shall be manner intended for use." 132 pdf_text
81 81. Insert the following definition: "EMERGENCY WARNING SYSTEM (for Chapter 11). A fire alarm or smoke or heat detector system used to a and visual emergency alarms." 8 pdf_text
82 82. Revise the definition of "employee work area" to read: "EMPLOYEE WORK AREA. All or any portion of a space used only by employees and only for work. Corridors, bathing rooms, locker rooms, kitchenettes and break rooms are not employee work areas." 8 pdf_text
83 83. Insert the following definition: "ENTRANCE (for Chapter 11). Any access point to a building or portion of a building or facility or multi-story ho entering. An entrance includes the approach pedestrian walkway, the vertical access leading to the entrance platform platform itself, vestibule, if provided, the entry door or gate and the hardware of the entry door or gate." 8 pdf_text
84 84. Insert the following definition: "ENVIRONMENTAL BARRIER (for Chapter 11). An element or space of the built environment which limits ac use of the built environment by individuals with disabilities." 8 pdf_text
85 85. Revise the definition of "exhausted enclosure" to read: "EXHAUSTED ENCLOSURE. As defined in Chapter 2 of the Chicago Fire Prevention Code." 8 pdf_text
85 (cont. 2) For SI: 1 foot = 304.8 mm. UL = Unlimited. NS = Buildings not equipped throughout with an automatic sprinkler system. S = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. S13R = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2. S13D = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.3. a. See Chapters 4 and 5 for specific exceptions to the allowable building height in this table. b. See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies. c. New Group H occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.5. d. The NS value is only for use in evaluation of existing buildings in accordance with the Chicago Building Rehabilitation Code. e. Group R occupancies of Type VA construction shall be allowed to be 40 feet in building height, provided that the finished floor level of the highest oc shall not exceed 30 feet above grade plane. f. Group R occupancies of Type VA construction equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903. allowed to be 55 feet in building height, provided that the finished floor level of the highest occupiable space shall not exceed 40 feet above gra g. 120 feet for evaluatio 37 pdf_text
85 (cont. 3) n of buildings constructed or permitted for construction before January 1, 1951, that are equipped throughout with an automatic s in accordance with Section 903.3.1.1. 37 pdf_text
86 86. Insert the following definition: "EXHIBITION AREA. A building, room or space used for temporary exhibition of goods, wares, merchandise or e other than a Group M occupancy." 8 pdf_text
87 87. Revise the definition of "existing building" to read: "EXISTING BUILDING. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 8 pdf_text
88 88. Revise the definition of "existing structure" to read: "EXISTING STRUCTURE. As defined in Chapter 2 of the Chicago Building Rehabilitation Code." 8 pdf_text
89 89. Revise the definition of "exit access" to read: "EXIT ACCESS. That portion of a means of egress system that leads from any occupiable space to an exit." 8 pdf_text
9 9,0 A-2 NS UL UL 41 pdf_text
9 9. Porches not over one story in height, and not over 10 feet (3048 mm) wide from the face of the bu provided that such porch does not come within 3 feet (914 mm) of any abutting property line and is n more than one building. 219 pdf_text
9 9. Revise Section 912.4.3 by deleting "Section 312 of." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 35; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 19) 81 pdf_text
9 9. Storage (see Section 311): Groups S-1 and S-2. 19 pdf_text
9 9. Revise Section 1202.4 by deleting "1202.4.2." 121 pdf_text
9 9. Revise row 26 of Table 1607.1 by deleting "except one- and two-family dwellings" and replacing "Occupiable ro "Occupiable rooftops." 147 pdf_text
9 9. Revise and renumber IBC Section E111 to read: "E112. REFERENCED STANDARDS DOJ 36 CFR Part 1192 Americans with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicl Washington, DC: Department of Justice, 1991" 220 pdf_text
9 9. Delete Section 1403.12 and its subsections. 129 pdf_text
9 9. Revise exception 4 to Section 714.5.2 by replacing "any material" with "any material allowed by the Chicago Ele 60 pdf_text
9 9. Revise Section 1705.5.1 by replace both instances of "approved" with "permitted." 158 pdf_text
9 9. Delete the exception to 907.2.2.1. 74 pdf_text
9 9,0 I-3 NS d, e UL UL 42 pdf_text
9 9. Delete Section 1808.7 and its subsections. 169 pdf_text
9 9,0 A-4 NS UL UL 41 pdf_text
9 9. Where panel doors are locked, an elevator-type key box, containing the panel door key, shall be pr immediate vicinity of the panels. 80 pdf_text
9 9. Revise Section 1006.2.2.6 to read: "1006.2.2.6 Groups R-3, R-4 and R-5. 88 pdf_text
9 9. Revise Section 1107.6 to read: "1107.6 Group R. Accessible units, Type A units and Type B units and units with communication features shall be provided in Group R accordance with Sections 1107.6.1 through 1107.6.4 and Appendix E." 113 pdf_text
9 9. Revise Section 905.3.8 to read: "905.3.8 Rooftop gardens, landscaped roofs, and occupiable rooftops. Buildings or structures that have vegetative roofs, rooftop gardens, landscaped roofs or occupiable rooftops and that with a standpipe system shall have the standpipe system extended to the roof level on which the vegetative roof, roof landscaped roof or occupiable rooftop is located." 72 pdf_text
9 9. Revise Table 1004.5 by adding a row for "Power plants" to read: "Power plants | 400 gross" 85 pdf_text
9 9. Revise Section 420.9 to read: "420.9 Group R cooking facilities. In Group R occupancies, cooking appliances used for domestic cooking operations and located within a dwelling uni unit shall be in accordance with the Chicago Mechanical Code. 34 pdf_text
9 9. Revise Section 2304.11.3.1 to read: "2304.11.3.1 Cross-laminated timber floors. Where approved for use, cross-laminated timber floors shall comply with this section. Cross-laminated timber floors less than 4 inches (102 mm) in actual thickness. Cross-laminated timber floors shall be continuous from support to s individual panels shall be mechanically fastened to one another. Cross- laminated timber floors shall be permitted to to walls without a shrinkage gap providing swelling or shrinking is considered in the design. Corbelling of masonry floor shall be permitted to be used." 184 pdf_text
9 9. Reductions for group action, where necessary." 164 pdf_text
9 9. Delete Section 403.3.1 and its subsections. 25 pdf_text
9 9. Revise the definitions of values for Equation 5-4 by replacing "public way or open space" with "public way, cour inserting "but not greater than 30 feet (9144 mm)" at the end of the definition of Wn . 44 pdf_text
9 9. Delete Section 1010.1.4.3. 93 pdf_text
9 9. Delete Table 1406.11.3.4. 132 pdf_text
9 9,0 M NS UL UL 42 pdf_text
9 9. Revise Section 717.5.4 by replacing "Ducts and air transfer openings" with "Air transfer openings." 62 pdf_text
9 9. Revise Section 1805.3.1 by replacing "approved" with "equivalent." 165 pdf_text
9 9. Revise Section 716.3.5.1 to read: "716.3.5.1 Fire window frames. Fire window frames shall only be used for intended applications." (Amend Coun. J. 6-25-21, p. 32180, Art. II, § 12) 62 pdf_text
9 9. Replace each occurrence of "International Plumbing Code" with "Chicago Plumbing Code." 2 pdf_text
9 9. Delete Section 3007.9 and its subsections. (Amend Coun. J. 1-24-24, p. 8634, Art. IV, § 6) 200 pdf_text
9 9. Revise Section 1011.6 to read: "1011.6 Stairway landings. There shall be a floor or landing at the top and bottom of each stairway. The width of landings, measured perpendicu direction of travel, shall be not less than the width of stairways served. Every landing shall have a minimum depth, parallel to the direction of travel, equal to the width of the stairway or 48 inches (1219 mm), whichever is less. Door a landing shall not reduce the landing by more than one-quarter the required width. Where wheelchair spaces are req stairway landing in accordance with Section 1009.6.3, the wheelchair space shall not be located in the required widt and doors shall not swing over the wheelchair spaces. Exceptions: 96 pdf_text
9 9. Delete Section 2603.4.1.8. 192 pdf_text
9 9. Revise Section 1510.7 to read: "1510.7 Photovoltaic panels and modules. Rooftop-mounted photovoltaic panels and modules shall be designed in accordance with this section and the Chicag Prevention Code." 139 pdf_text
9 9,500 NP NP N 41 pdf_text
9 9. Delete Section 2702.2.5. 196 pdf_text
9 9. Revise Section D102.2.7 to read: "D102.2.7 Projections. Projections extending beyond the exterior wall on buildings located in the fire limits shall be constructed of noncom materials." 218 pdf_text
9 9. Emergency and standby power status indicators. 80 pdf_text
9 9. Delete Section 308.5.2. 21 pdf_text
9 9. Revise Section 2303.2.5 by replacing "an approved method" with "a method." 183 pdf_text
9 9. Delete the following standard under AWC: ANSI/AWC PWF–2015. 217 pdf_text
9 9,0 I-2 NS d, f UL UL 42 pdf_text
9 9. Revise note i to Table 307.1(2) to delete "Section 5003.1.2 of." 20 pdf_text
9 9,0 I-4 NS d, g UL 42 pdf_text
9 9. Insert Tables 705.8(1) and 705.8(2) as shown: TABLE 705.8(1) MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEG OPENING PROTECTION FOR BUILDINGS NOT COVERED BY TABLE 705.8(2) 54 pdf_text
9 9. Revise items 1 and 2 in Section 1803.5.8 to read: "1. Recommended specifications for the preparation of the site prior to placement of compacted fill material 164 pdf_text
9 9,0 A-3 NS UL UL 41 pdf_text
9 9. Revise Table 1507.8 by deleting "(Type 316 for coastal areas)." 137 pdf_text
9 9,0 A-5 NS UL UL UL UL UL UL UL U S1 UL SM UL B NS UL UL 41 pdf_text
9 9. Revise Section 603.1.3 by replacing "this code" with "the Chicago Electrical Code." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 22) 50 pdf_text
9 9. Revise note d to Table 2308.4.1.1(2) by replacing "an approved framing anchor" with "a framing anchor." 185 pdf_text
9 9. Delete item 4 in Section 1807.1.6.3.2. 168 pdf_text
9 9. Revise Section 1810.3.2.5 by replacing "approved by the building official" with "recommended by the registered engineer." 170 pdf_text
9 9. Revise Section 903.2.1.6, including the exception, to read: "903.2.1.6 Assembly occupancies on roofs. Where an occupiable rooftop has an assembly occupancy with an occupant load of 300 or more, all floors between t rooftop and the level of exit discharge shall be equipped with an automatic sprinkler system in accordance with Secti 68 pdf_text
9 9. Delete Table 1609.3.1. 149 pdf_text
9 9. The third and fourth story above grade plane in a townhouse, provided all the following criteria ar 90 pdf_text
9 9. Revise Section 1404.5 to read: "1404.5 Wood veneers. Wood veneers on exterior walls of buildings of Type I, II, III and IV construction shall be not less than 1 inch (25 m thickness and shall conform to the following: 129 pdf_text
9 9. Delete Section 406.5.1. 30 pdf_text
9 9,0 E-2 NS UL UL 41 pdf_text
9 9. Revise Section 706.5.2, including the exceptions, to read: "706.5.2 Horizontal projecting elements. Fire walls shall extend to the outer edge of horizontal projecting elements such as porches, exterior balconies, roof o canopies, marquees and similar projections that are within 4 feet (1220 mm) of the fire wall." 57 pdf_text
9 9. Revise the definition of "aerosol container" to read: "AEROSOL CONTAINER. As defined in Chapter 2 of the Chicago Fire Prevention Code." 4 pdf_text
9 9. Revise Section 1704.4 to read: "1704.4 Contractor responsibility. Each contractor responsible for the construction of a seismic force-resisting system, designated seismic system or a s resisting component listed in the statement of special inspections shall submit a written statement of responsibility to prior to the commencement of work on the system or component. The contractor’s statement of responsibility shall c acknowledgement of awareness of the special requirements contained in the statement of special inspections." 156 pdf_text
9 9,0 F-1 NS UL UL 41 pdf_text
9.1 9.1. Delete Table 2308.4.2.1(1). 185 pdf_text
9.1 9.1. Insert a new section to read: " CRRC Cool Roof R 217 pdf_text
9.1 9.1. Revise Section 1011.7 to read: "1011.7 Stairway construction. Stairways shall be built of materials consistent with the type of construction of the building. Exceptions: 97 pdf_text
9.1 9.1. The townhouse construction type is I, IIA, IIIA or IV. 90 pdf_text
9.2 9.2. The floor area of the story does not exceed 1,500 square feet (139.4 m2). 90 pdf_text
9.2 9.2. Delete the following standard under DASMA: ANSI/DASMA 115–2016. 217 pdf_text
9.3 9.3. At least one exit access stairway is contained within the townhouse and leads directly to the level of exit discharge. 90 pdf_text
9.4 9.4. An egress balcony complying with Section 1021 shall connect at least 3 townhouses at t story to an interior exit stairway. 90 pdf_text
9.5 9.5. Each habitable space more than two stories above grade plane shall have a window with net clear opening of 5.7 square feet (0.53 m2), the bottom of which is not more than 44 inches above the floor. 90 pdf_text
9.6 9.6. Each room in the townhouse used for sleeping purposes shall be provided with solid woo less than 1-3/4 inches (45 mm) in thickness in a rabbeted frame, or doors in compliance with S 90 pdf_text
90 90. Revise the definition of "explosion" to read: "EXPLOSION. As defined in Chapter 2 of the Chicago Fire Prevention Code." 8 pdf_text
90 90 air changes per hour from any vestibule in the emergency operation mode and shall be size three vestibules simultaneously. Smoke detectors shall be located at the floor-side entrance to and shall activate the system for the affected vestibule. Smoke detectors shall be installed in ac 229 pdf_text
901.6.1 901.6.1 Automatic sprinkler systems. Automatic sprinkler systems shall be monitored by a supervising station. Exceptions: 67 pdf_text
901.6.3 901.6.3 Fire alarm systems. Fire alarm systems required by the provisions of Section 907.2 of this code shall be monitored by a supervisi accordance with Section 907.6.6 of this code. Exceptions: 67 pdf_text
901.6.4 901.6.4 Group H. Supervision and monitoring of emergency alarm, detection and automatic fire-extinguishing systems in Grou occupancies shall be in accordance with the Chicago Fire Prevention Code." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 28; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 13) 67 pdf_text
903.2.2.1 903.2.2.1 Ambulatory care facilities. An automatic sprinkler system shall be installed throughout the entire floor containing an ambulatory care fa either of the following conditions exist at any time: 68 pdf_text
903.2.2.2 903.2.2.2 Telephone exchanges. An automatic fire-extinguishing system shall be installed throughout buildings containing telephone exchang 68 pdf_text
903.3.1.1 903.3.1.1 or 903.3.1.2, the separation distance shall be not less than one-third of the length of t overall diagonal dimension of the area served. 91 pdf_text
903.3.1.1 903.3.1.1, the fire-resistance rating shall be not less than one hour. 124 pdf_text
905.2.2 905.2.2 Multiple systems required. In buildings where the floor level of the highest story is more than 275 feet (83.8 m) above grade plane, two or more standpipe systems shall be provided. The lowest standpipe system shall serve the portion up to and including the stor feet (83.8 m) or less above grade plane. Above 275 feet (83.8 m) additional standpipe systems shall be provided to s not more than 20 stories each. 71 pdf_text
905.2.3 905.2.3 Express risers. 71 pdf_text
905.2.4 905.2.4 Pressure reducing devices. Where the pressure at nozzles is more than 65 pounds per square inch (448 kN/m2), the 1 1/2-inch hose valve shall b with a device or disk to limit the force of the hose stream to 90 pounds (0.4 kN) so that the nozzle can be safely hand person." 72 pdf_text
906.9.2 906.9.2 Type of construction. Parking facilities shall be of Type IA construction. 31 pdf_text
906.9.3 906.9.3 Fire protection systems. An automatic sprinkler system is not required in parking facilities except where four or more levels are enclosed on Standpipes are not required in parking facilities, except a manual dry standpipe system shall be required in parking f exceed 55 feet (16.7 m) in building height. A fire alarm system is not required in parking facilities that do not exceed m) in building height. 31 pdf_text
906.9.4 906.9.4 Emergency lighting. A System III emergency lighting system shall be provided in parking facilities in accordance with Article 700 of the Electrical Code." (Amend Coun. J. 7-24-19, p. 3646, § 27; Amend Coun. J. 2-19-20, p. 14473, Art. II, § 9; Amend Coun. J. 10-7-20, p. 21791, Amend Coun. J. 1-26-22, p. 43756, Art. II, § 3) 31 pdf_text
907.2.12.2.1 907.2.12.2.1 Fire department two-way communication system. A two-way fire department communication system shall be provided to operate between a fire command cent with Section 911 and emergency two-way stations located at not less than every fifth level and every landing numbered with a multiple of 5 and the uppermost landing within every interior exit stairway. 76 pdf_text
907.2.12.2.2 907.2.12.2.2 Selective one-way communication system. A selective (multiple-channel) one-way communication system shall be provided to operate between a fire co complying with Section 911 and the following areas: 76 pdf_text
907.2.12.2.3 907.2.12.2.3 Combined system. The two-way fire department communication system may be combined with the one-way system where appr code official." 77 pdf_text
907.3 907.3. S101.20.6.1 Ventilation systems. Smokeproof enclosure ventilation systems shall be independent of other building ventilation systems. equipment, control wiring, power wiring and ductwork shall comply with one of the following: 229 pdf_text
907.5 907.5, unless other requirements are provided by another section of this code. Not fewer than one manual fire alarm box at each exit on the level of exit discharge shall be provided to initiate a fire for fire alarm systems employing automatic fire detectors or waterflow detection devices. Where other sections of thi elimination of manual fire alarm boxes due to sprinklers, manual fire alarm boxes shall be installed at each exit on th discharge. Exception: The manual fire alarm box is not required for fire alarm systems dedicated to elevator recall cont supervisory service." 74 pdf_text
909.1 909.1 Smoke control for atriums. Where required by Section 404.5, atriums shall be provided with a smoke control system meeting the following requ 78 pdf_text
909.2 909.2 Acceptance. Buildings, or portions thereof, required by this code to comply with this section shall not be issued a certificate of oc such time that the fire code official determines that the provisions of this section have been fully complied with and t department has received satisfactory instruction on the operation, both automatic and manual, of the system and a wr maintenance program complying with the requirements of the Chicago Fire Prevention Code has been submitted to by the fire code official. Exception: Where phased construction is permitted, a temporary certificate of occupancy shall be allowed pr 78 pdf_text
909.3 909.3 Optional smoke control systems. Optional smoke control systems shall comply with Appendix S." (Amend Coun. J. 2-19-20, p. 14473, Art. II, § 34; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 18) 79 pdf_text
91 91. Revise the definition of "explosive" to read: "EXPLOSIVE. As defined in Chapter 2 of the Chicago Fire Prevention Code." 8 pdf_text
919.1 919.1 Placement. A city fire alarm box shall be placed within 100 feet (30.5 m) from the principal entrance of the following occupanci 82 pdf_text
919.2 919.2 Connection. The fire alarm systems required for the occupancies listed in Section 919.1 shall be directly connected to the city fire Exception: Where the fire alarm system is directly connected to a UL-listed central station fire alarm service private supervisory service is not prohibited by the fire code official. 83 pdf_text
919.2.1 919.2.1 Other occupancies. Fire alarm systems for occupancies other than those listed in Section 919.1 shall not be connected to a city fir Exception: Occupancies listed in Section 919.1 with an occupant load less than provided may be con fire alarm box. 83 pdf_text
919.3 919.3 Multiple connections. The fire alarm systems of no more than one building shall be connected to any one city fire alarm box. Exception: Fire alarm systems in a building that was permitted to be connected to a common city fire alarm July 1, 1971." CHAPTER 14B-10 MEANS OF EGRESS 83 pdf_text
92 92. Insert the following definition: "EXTERIOR BALCONY. An exterior floor structure, other than an occupiable rooftop, that is attached to the exte building, with all means of egress requiring travel through the building, and that is open to the atmosphere on at least 8 pdf_text
93 93. Revise the definition of "facility" to read: "FACILITY. All or any portion of buildings, structures, site improvements, elements and pedestrian or vehicular ro a site." 8 pdf_text
94 94. Insert the following definition: "FENCE. A structure, independent of other structures, forming a barrier at ground level between lots, between a lot way or between portions of the same lot." 8 pdf_text
95 95. Insert the following definition: "FIRE ALARM BOX, CITY. See "City fire alarm box." 9 pdf_text
96 96. Insert the following definition: "FIRE CODE OFFICIAL. As defined in Chapter 2 of the Chicago Construction Codes Administrative Provisions." 9 pdf_text
97 97. Revise the definition of "fire separation distance" to read: "FIRE SEPARATION DISTANCE. The horizontal distance measured from the building face or element to one of 9 pdf_text
98 98. Revise the definition of "fire wall" to read: "FIRE WALL. A fire-resistance-rated wall having protected openings, which restricts the spread of fire and extends from the foundation to or through the roof. " 9 pdf_text
98.1 98.1 Revise the definition of "fireworks" to read: "FIREWORKS. As defined in Chapter 2 of the Chicago Fire Prevention Code." 9 pdf_text
99 99. Revise the definition of "flammable gas" to read: "FLAMMABLE GAS. As defined in Chapter 2 of the Chicago Fire Prevention Code." 9 pdf_text
Section 1006.2.2.6 Section 1006.2.2.6. h. 20 in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. For spaces in Group R occupancies req 88 pdf_text
Section 1013 Section 1013. Directional exit markings, acceptable to the fire code official, shall be provided. Where mirrors, mazes designs are utilized that disguise the path of egress travel such that they are not apparent, listed low-level exit signs t with Section 1013, and directional path markings listed in accordance with UL 1994, shall be provided and located n inches (203 mm) above the walking surface and on or near the path of egress travel. Such markings shall become vis emergency. The directional exit marking shall be activated by the automatic fire detection system and the automatic system in accordance with Section 907.2.11." 32 pdf_text
Section 1202.5 Section 1202.5 shall be provided in all living, dining and sleeping rooms with a floor area of 7 (6.5 m 2 ) or more. 120 pdf_text
Section 1204.2 Section 1204.2 and artificial light in accordance with Section 1204.3." 122 pdf_text
Section 1205.3.2 Section 1205.3.2. Inner courts shall comply with Section 1205.3.3. 124 pdf_text
Section 1607.11 Section 1607.11 for floors." 148 pdf_text
Section 1608 Section 1608, in accordance with Section 1605, acting on all portions of the structure. 146 pdf_text
Section 1608 Section 1608, in accordance with Section 1605, acting on the cantilevered portion of the structure, an or snow load on the remaining portion of the structure." 146 pdf_text
Section 1609.6.2 Section 1609.6.2 for components and cladding.) f. All wind loads are ultimate wind loads (W) and shall be utilized in load combinations using strength or load and resistance factor design per Section 1 required, service level loads may be obtained by dividing the values in the table by 1.6, however these service level loads shall not be used for e load combination prescribed in Section 1605.2 or 1605.3.1. g. Projecting elements such as flag poles, sign structures, tanks and towers shall be designed in accordance with ASCE 7. 150 pdf_text
Section 1810.2.1 Section 1810.2.1 is provided for the entire height and a reinforcing cage is provided for the ful an engineering analysis shows that a full depth cage is unnecessary. 170 pdf_text
Section 1810.3.5.3.4 Section 1810.3.5.3.4 or bedrock 171 pdf_text
Section 1810.3.9.4.2 Section 1810.3.9.4.2. Exceptions: 174 pdf_text
Section 2702 Section 2702. Smoke alarms, heat alarms and heat detectors shall emit a signal when the batteries are low. Wiring sh permanent and without a disconnecting switch other than as required for overcurrent protection. Exception: Smoke alarms, heat alarms and heat detectors are not required to be equipped with battery backu are connected to an emergency electrical system that complies with Section 2702." 75 pdf_text
Section 308 Section 308. The hand shower shall have a control with a nonpositive shut-off feature. Where provided, an ad hand shower mounted on a vertical bar shall be installed so as to not obstruct the use of grab bars. Shower spr deliver water that does not exceed the maximum temperature allowed by the Chicago Plumbing Code. EXCEPTION: Slopes not steeper than 1:48 shall be permitted." 108 pdf_text
Section 3102 Section 3102 unless otherwise approved by the building official. 201 pdf_text
Section 505 Section 505, and lofts that comply with Section 1207.5 shall not be considered stories for purp section. 59 pdf_text
Section 508 Section 508. Where a building is proposed for a purpose that is not specifically listed in this section, such building sh classified in the occupancy it most nearly resembles based on the fire safety and relative hazard as approved by the b official. 19 pdf_text
Section 602 Section 602 and the occupancies as determined by Section 302 except as modified hereafter. Building height, numbe above grade plane and building area provisions shall be applied independently. For the purposes of determining buil limitations, building height limitations and type of construction, each portion of a structure separated by one or more complying with Section 706 shall be considered to be a separate building." 36 pdf_text
Section 705 Section 705 based on fire separation distance." 102 pdf_text
Section 705 Section 705 based on fire separation distance. Exceptions: 104 pdf_text
Section 709 Section 709. The maximum allowable leakage area shall be the aggregate area calculated using the following leakag 221 pdf_text
Section 903.3.1.1 Section 903.3.1.1, S = 2; where building is not equipped throughout wit sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2, S = (Amend Coun. J. 7-24-19, p. 3646, § 30; Amend Coun. J. 10-7-20, p. 21791, Art. II, § 7; Amend Coun. J. 6-25-21, p. § 6) 44 pdf_text
Section 903.3.1.1 Section 903.3.1.1 or 903.3.1.2." 57 pdf_text
Section 905 Section 905 if it can be relocated so that at least that shelf is 48 inches (1220 mm) max the floor without damaging the storage facility or adjacent cabinetry, walls, wall finish, structural elements. The wall behind the relocatable storage facility shall be finished." 109 pdf_text
Section 907.3 Section 907.3. S101.20.4.3 Smoke trap. The vestibule ceiling shall be not less than 20 inches (508 mm) higher than the door opening into the serve as a smoke and heat trap and to provide an upward-moving air column. The height shall not be unless approved and justified by design and test. S101.20.4.4 Stairway or ramp shaft air movement system. The stairway or ramp shaft shall be provided with a dampered relief opening and supplied with suffic maintain a minimum positive pressure of 0.10 inch of water (25 Pa) in the shaft relative to the vestibu doors closed. S101.20.5 Stairway and ramp pressurization alternative. Where the building is equipped throughout with an automatic sprinkler system in accordance with Section 90 vestibule is not required, provided that each interior exit stairway or ramp is pressurized to not less than 0.10 (25 Pa) and not more than 0.35 inches of water (87 Pa) in the shaft relative to the building measured with all i stairway and ramp doors closed under maximum anticipated conditions of stack effect and wind effect. S101.20.6 Ventilating equipment. The activation of ventilating equipment required by the alternatives in Sections S101.20.4 and S101.20.5 shal detectors installed at each floor level and at each entrance to the smokeproof enclosure. When the closing dev stairway and ramp shaft and vestibule doors is activated by smoke detection or power failure, the mechanical shall activate and operate at the required performance levels. Smoke detectors 229 pdf_text
Section 907.3 (cont. 2) shall be installed in accordance 229 pdf_text
Section 907.5 Section 907.5 upon sprinkler water flow." 74 pdf_text
full-text The pressurization system shall be provided with standby power in accordance with Section 2702. S101.21.6 Activation of pressurization system. The elevator pressurization system shall be activated upon activation of either the building fire alarm system lobby smoke detectors. Where both a building fire alarm system and elevator lobby smoke detectors are prese be independently capable of activating the pressurization system. S101.21.7 Testing. Testing for performance shall be required in accordance with Section S101.18.8. System acceptance shall be with Section S101.19. S101.21.8 Marking and identification. Detection and control systems shall be marked in accordance with Section S101.14. S101.21.9 Control diagrams. Control diagrams shall be provided in accordance with Section S101.15. S101.21.10 Control panel. A control panel complying with Section S101.16 shall be provided. S101.21.11 System response time. Hoistway pressurization systems shall comply with the requirements for smoke control system response time S101.17. S101.22 Maintenance. Smoke control systems shall be maintained to ensure to a reasonable degree that the system is capable of controlling duration required. The system shall be maintained in accordance with the manufacturer’s instructions and Sections S through S101.22.6. S101.22.1 Schedule. A routine maintenance and operational testing program shall be initiated immediately after the smoke control passed the acceptance tests. A written schedule for routine 231 pdf_text
full-text Fdc = Force required to overcome closing device, pounds (N). K = Coefficient 5.2 (1.0). W = Door width, feet (m). ΔP = Design pressure difference, inches of water (Pa). S101.6.3 Pressurized stairways and elevator hoistways. Where stairways or elevator hoistways are pressurized, such pressurization systems shall comply with Sectio smoke control systems, in addition to the requirements of Sections S101.20 of this code and the entire Chicag Prevention Code. S101.7 Airflow design method. Where approved by the fire code official, smoke migration through openings fixed in a permanently open position, w located between smoke control zones by the use of the airflow method, shall be permitted. The design airflow shall b accordance with this section. Airflow shall be directed to limit smoke migration from the fire zone. The geometry of be considered to prevent flow reversal from turbulent effects. Smoke control systems using the airflow method shall accordance with NFPA 92. S101.7.1 Prohibited conditions. This method shall not be employed where either the quantity of air or the velocity of the airflow will adversel portions of the smoke control system, unduly intensify the fire, disrupt plume dynamics or interfere with exiti toward the fire shall not exceed 200 feet per minute (1.02 m/s). Where the calculated airflow exceeds this lim method shall not be used. S101.8 Exhaust method. Where approved by the fire code official, mechanical smoke control for large enclosed v 223 pdf_text
full-text For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa. a. Classified in accordance with Table 1806.2(3). b. Requires engineering analysis and testing by a registered geotechnical engineer. c. 1 foot into sound rock (recovery greater than 95% and RQD greater than 70%) with 20% increase per foot of additional penetration up to a maximum pounds per square foot. d. Surface of refusal to standard caisson rig rock auger, correlated to borings with recovery greater than 90% and RQD greater 40%, rock unconfined co greater than 2,000 pounds per square inch. e. Surface of refusal to standard caisson rig rock auger, correlated to borings with recovery greater than 90% and RQD greater than 50%, rock unconfin strength greater than 2,500 pounds per square inch. f. Surface of refusal to standard caisson rig rock auger, correlated to borings with recovery greater than 95% and RQD greater than 60%, rock unconfin strength greater than 3,000 pounds per square inch. g. Surface of refusal to standard caisson rig rock auger, correlated to borings with recovery greater than 95% and RQD greater than 70%, rock unconfin strength greater than 3,500 pounds per square inch. h. No load tests are required up to presumptive bearing pressures. If higher bearing pressures are required than shown in table or RQD or rock compress not meet values shown, load tests are required to confirm allowable bearing pressure. i. Where qu is greater than 14,000 pounds per square foot, or N is gre 167 pdf_text
full-text TITLE 14B BUILDING CODE* * Editor’s note – Title 14B was added by Coun. J. 4-10-19, p. 100029, Art. III, § 1. This title incorporates provisions of the 2018 International Building Code®, whi International Code Council, Inc. (ICC). These provisions are incorporated by reference and not reprinted in the ordinance. A free, read-only document which compile provisions and amendments adopted by the City of Chicago, hosted by ICC, can be viewed at: https://codes.iccsafe.org/content/CHIBC2019P1. For frequent users of compiled version of the Chicago Building Code is available for purchase from ICC in print and electronic formats. Provisions governing effective dates for provisions found in Section 14A-1-105. Ch. 14B-1 Scope and Purpose Ch. 14B-2 Definitions and Measurements Ch. 14B-3 Occupancy Classification and Use Ch. 14B-4 Special Detailed Requirements Based on Use and Occupancy Ch. 14B-5 General Building Heights and Areas Ch. 14B-6 Types of Construction Ch. 14B-7 Fire and Smoke Protection Features Ch. 14B-8 Interior Finishes Ch. 14B-9 Fire Protection and Life Safety Systems Ch. 14B-10 Means of Egress Ch. 14B-11 Accessibility Ch. 14B-12 Interior Environment Ch. 14B-13 Energy Efficiency Ch. 14B-14 Exterior Walls Ch. 14B-15 Roof Assemblies and Rooftop Structures Ch. 14B-16 Structural Design Ch. 14B-17 Special Inspections and Tests Ch. 14B-18 Soils and Foundations Ch. 14B-19 Concrete Ch. 1 pdf_text
full-text m = Exhaust rate, pounds per second (kg/s). Qc = Convective heat output of fire, Btu/s (kW). Ta = Ambient temperature, °F (K). Ts = Smoke temperature, °F (K). Exception: Reduced Ts as calculated based on the assurance of adequate dilution air. S101.10.2 Ducts. Duct materials and joints shall be capable of withstanding the probable temperatures and pressures to which t exposed as determined in accordance with Section S101.10.1. Ducts shall be constructed and supported in ac the Chicago Mechanical Code. Ducts shall be leak tested to 1.5 times the maximum design pressure in accor nationally accepted practices. Measured leakage shall not exceed 5 percent of design flow. Results of such tes part of the documentation procedure. Ducts shall be supported directly from fire-resistance-rated structural el building by substantial, noncombustible supports. Exception: Flexible connections, for the purpose of vibration isolation, complying with the Chicago Code and that are constructed of fire-resistance-rated materials. S101.10.3 Equipment, inlets and outlets. Equipment shall be located so as to not expose uninvolved portions of the building to an additional fire hazar inlets shall be located so as to minimize the potential for introducing smoke or flame into the building. Exhau be so located as to minimize reintroduction of smoke into the building and to limit exposure of the building o buildings to an additional fire hazard. S101.10.4 Automatic dampers. Automatic damper 224 pdf_text
full-text (cont. 2) ater than or equal to 50. j. Where qu is greater than or equal to 8,000 pounds per square foot, or N is greater than or equal to 30. k. Allowable net bearing value assumes minimum depth of embedment is 2.5 feet and a minimum width of 1.5 feet. Allowable bearing values shall be r proportionally for less depth of embedment, or the effect of reduced confinement from a rise in the water table above the foundation level. l. [Reserved.] m. Organic means more than 10% organic matter as determined in accordance with ASTM D2974. n. Presumptive value for light or temporary structure. Otherwise engineering analysis required. o. Controlled fill shall be placed in specified lifts with moisture control, under full time observation of a registered geotechnical engineer or their qualifi in accordance with ASTM D1557. p. Improved fill or soil in-situ by dynamic compaction, compaction grouting, or other methods. TABLE 1806.2(3) STANDARDS FOR CLASSIFYING SOIL CONSISTENCY AND RELATIVE DENSITY 167 pdf_text
full-text (cont. 2) maintenance and operational testing shall be estab S101.22.2 Records. Records of smoke control system testing and maintenance shall be maintained. The record shall include the d maintenance, identification of the servicing personnel and notification of any unsatisfactory condition and the action taken, including parts replaced. S101.22.3 Testing. Operational testing of the smoke control system shall include all equipment such as initiating devices, fans, d controls, doors and windows. S101.22.4 Dedicated smoke control systems. Dedicated smoke control systems shall be operated for each control sequence semiannually. The system shall under standby power conditions. S101.22.5 Nondedicated smoke control systems. Nondedicated smoke control systems shall be operated for each control sequence annually. The system shall standby power conditions. S101.22.6 Components bypassing weekly test. Where components of the smoke control system are bypassed by the preprogrammed weekly test required by S101.12.1, such components shall be tested semiannually. The system shall be tested under standby power co (Amend Coun. J. 10-7-20, p. 21791, Art. II, § 35) 231 pdf_text
full-text (cont. 2) s, regardless of the purpose for which they are installed within the smoke control system, s and conform to the requirements of recognized standards. S101.10.5 Fans. In addition to other requirements, belt-driven fans shall have 1.5 times the number of belts required for the de the minimum number of belts being two. Fans shall be selected for stable performance based on normal temp where applicable, elevated temperature. Calculations and manufacturer’s fan curves shall be part of the docu procedures. Fans shall be supported and restrained by noncombustible devices in accordance with the require Chapter 16. Motors driving fans shall not be operated beyond their nameplate horsepower (kilowatts), as determined from of actual current draw, and shall have a minimum service factor of 1.15. S101.11 Standby power. Smoke control systems shall be provided with standby power in accordance with Section 2702. S101.11.1 Equipment room. The standby power source and its transfer switches shall be in a room separate from the normal power transfo switch gears and ventilated directly to and from the exterior. The room shall be enclosed with not less than 1- barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with or both. S101.11.2 Power sources and power surges. Elements of the smoke control system relying on volatile memories or the like shall be supplied with uninterr sources of sufficient duration to span 15-minute primary power interrupti 224 pdf_text
full-text (cont. 2) olumes, such as in atriums, s permitted to utilize the exhaust method. Smoke control systems using the exhaust method shall be designed in accord NFPA 92. S101.8.1 Smoke layer. The height of the lowest horizontal surface of the smoke layer interface shall be maintained not less than 6 fe above a walking surface that forms a portion of a required egress system within the smoke zone. S101.9 Design fire. The design fire shall be based on a rational analysis performed by the registered design professional and approved b official. The design fire shall be based on the analysis in accordance with Section S101.4 and this section. S101.9.1 Factors considered. The engineering analysis shall include the characteristics of the fuel, fuel load, effects included by the fire an fire is likely to be steady or unsteady. S101.9.2 Design fire fuel. Determination of the design fire shall include consideration of the type of fuel, fuel spacing and configuration S101.9.3 Heat-release assumptions. The analysis shall make use of best available data and shall not be based on excessively stringent limitations material. S101.9.4 Sprinkler effectiveness assumptions. A documented engineering analysis shall be provided for conditions that assume fire growth is halted at the ti sprinkler activation. S101.10 Equipment. Equipment including, but not limited to, fans, ducts, automatic dampers and balance dampers, shall be suitable for its and suitable for the probable exposure temperatures that the rational 223 pdf_text
full-text (cont. 2) 14B-20 Aluminum Ch. 14B-21 Masonry Ch. 14B-22 Steel Ch. 14B-23 Wood Ch. 14B-24 Glass and Glazing Ch. 14B-25 Gypsum Board, Gypsum Panel Products and Plaster Ch. 14B-26 Plastic Ch. 14B-27 Electrical Ch. 14B-28 Mechanical Systems Ch. 14B-29 Plumbing Systems Ch. 14B-30 Conveyance Devices Ch. 14B-31 Special Construction Ch. 14B-32 Encroachments into the Public Way Ch. 14B-33 Work Site Safety and Operations Ch. 14B-34 Reserved Ch. 14B-35 Referenced Standards Ch. 14B-36 Appendices 1 pdf_text
full-text (cont. 3) on. Elements of the smoke control s susceptible to power surges shall be suitably protected by conditioners, suppressors or other approved means. S101.12 Detection and control systems. Fire detection systems providing control input or output signals to mechanical smoke control systems or elements the comply with the requirements of Section 907. Such systems shall be equipped with a control unit complying with U as smoke control equipment. S101.12.1 Verification. Control systems for mechanical smoke control systems shall include provisions for verification. Verification positive confirmation of actuation, testing, manual override and the presence of power downstream of all disc preprogrammed weekly test sequence shall report abnormal conditions audibly, visually and by printed report preprogrammed weekly test shall operate all devices, equipment and components used for smoke control. Exception: Where verification of individual components tested through the preprogrammed weekly t sequence will interfere with, and produce unwanted effects to, normal building operation, such indivi components are permitted to be bypassed from the preprogrammed weekly testing, where approved b 224 pdf_text
full-text (cont. 3) analysis indicates. S101.10.1 Exhaust fans. Components of exhaust fans shall be rated and certified by the manufacturer for the probable temperature rise components will be exposed. This temperature rise shall be computed by: Ts= (Qc / mc) + (Ta) (Equation S-2) where: c = Specific heat of smoke at smoke layer temperature, Btu/lb°F (kJ/kg • K). 223 pdf_text