| Label | Text | Page | Extraction method |
| 0493 |
0493," and "International Code Council, Inc., 500 New Jersey Avenue, NW, 6th Fl
Washington D.C. 20001, tel: 888-422-7233." |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Administration, shall be deleted in its entirety. In addition, an
referenced section of Chapter 1 shall be deleted throughout the code and "the administ
provisions of the Uniform Construction Code (N.J.A.C. 5:23)" shall be inserted. |
- |
pdf_text |
| 1 |
1. Plan review for the construction of a new school shall always be the responsibility
Department. For projects other than the construction of a new school, the local enforci
agency may review the plans in accordance with (b) below.
(b) In lieu of obtaining construction code plan review and release from the Department of
Community Affairs, a school district may secure construction code plan review and releas
municipal code enforcing agency, pursuant to P.L. 1990, c.23. |
- |
pdf_text |
| 1 |
1. Where the floor areas adjacent to a horizontal exit are reachable from exit st
outlets by a 30-foot (9,144 mm) hose stream from a nozzle attached to 100 feet
mm) of hose, a hose connection shall not be required at the horizontal exit. |
- |
pdf_text |
| 1 |
1. Building materials and supplies: |
- |
pdf_text |
| 1 |
1. Pursuant to the authority at P.L. 1975, c. 217, as modified at P.L. 1996, c. 53, the
Commissioner hereby adopts the following portions of the building, electrical, mechan
fuel gas, and one- and two-family dwelling subcodes, to the extent delineated at N.J.A |
- |
pdf_text |
| 1 |
1. Pursuant to the authority at P.L. 1975, c. 217, as modified at P.L. 1996, c. 53, the
Commissioner hereby adopts the Model Code of the International Association of Plum
Mechanical Officials, known as "The National Standard Plumbing Code/2024," as the
plumbing subcode for New Jersey.
i. Copies of this code may be obtained from the sponsor at: New Jersey PHCC, 18
Bergen Place, Red Bank, NJ 07701. |
- |
pdf_text |
| 1 |
1
Scope and Administration
As applicable
As applicable
(R
E)
C
h. |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Application, shall be amended as follows:
i. Sections C101.1, Title, and C101.3, Intent, shall be deleted.
ii. Section C101.4, Compliance, and Section C102.1.1, Mixed residential and com
buildings, shall have "by means of the ASHRAE Standard 90.1" inserted after "IE
Commercial Provisions."
iii. Sections C102.2, Other laws; C102.5, Partial invalidity; C103, Code Complian
Agency; C104, Alternative Materials, Design And Methods Of Construction and
Equipment; C105, Construction Documents; C106, Fees; C107, Inspections; C108 |
- |
pdf_text |
| 1 |
1, 3, 4, 5, and 6, "C," shall be deleted in reference to seismic design categories.
xxxiv. In Section 1705.13.8, Seismic isolation systems, in the first sentence of the
paragraph, "B" and "C," shall be deleted in reference to seismic design categories.
xxxv. Section 1705.14.1, Structural steel, shall be deleted.
xxxvi. In Section 1705.14.2, Nonstructural components, in the first sentence, "B a
shall be deleted in reference to seismic design categories. Additionally, in the seco
sentence, "building official" shall be deleted and "construction official" shall be in
xxxvii. In Section 1705.14.3, Designated seismic systems, in the first sentence, "C
be deleted in reference to seismic design categories. Additionally, in the second se
"building official" shall be deleted and "construction official" shall be inserted.
xxxviii. In Section 1705.14.4, Seismic isolation systems, in the first sentence, "B
shall be deleted in reference to seismic design categories.
xxxix. In Section 1707.1, General, in two places in the first sentence, "building of
shall be deleted and "construction official" shall be inserted. Additionally, "as prov
in Section 104.11" shall be deleted and "in accordance with N.J.A.C. 5:23-3.7" sha
inserted in its place. |
- |
pdf_text |
| 1 |
1. Pursuant to the authority of P.L. 1975, c. 217, as modified by P.L. 1996, c. 53, the
Commissioner hereby adopts the model code of the National Fire Protection Associati
known as "The National Electrical Code (NEC) 2020," and Tentative Interim Amend
and 19 as the electrical subcode for New Jersey.
i. Copies of this code may be obtained from the sponsors at NFPA, One Batterym
Park, Quincy, Massachusetts 02169. |
- |
pdf_text |
| 1 |
1. Names and addresses of the owners of the tent or air-supported structure. |
- |
pdf_text |
| 1 |
1. An auxiliary service counter with a maximum height of 36 inches in close p
to the main service counter |
- |
pdf_text |
| 1 |
1. Pursuant to authority of P.L. 1975, c. 217, as modified by P.L. 1996, c. 53, the
Commissioner hereby adopts the model code of the International Code Council, 2021
International Residential Code known as the "IRC/2021" as the one- and two-family d
subcode in New Jersey subject to the modifications stated at (c) below.
i. Copies of this code may be obtained from the International Code Council at 405
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The IRC/2021 may be known and cited as the one- and two-family dwelling su
(b) The provisions of this subcode shall apply to detached one- and two-family dwellings
townhouses not more than three stories above grade plane in height with a separate means
egress serving each dwelling unit and their accessory structures.
(c) The following chapters or sections of the IRC/2021 shall be modified as follows: |
- |
pdf_text |
| 1 |
1. Chapter 1 of the fuel gas subcode, entitled "Scope and Administration," the subsect
deleted and "The applicable administrative provisions of the Uniform Construction Co
(N.J.A.C. 5:23) shall apply." shall be inserted at each section title, except that the "alte
materials" section shall state "The provisions of N.J.A.C. 5:23-3.7 shall apply.". |
- |
pdf_text |
| 1 |
1. Garden-type utility sheds and similar structures that are 100 square feet or l
area, 10 feet or less in height and accessory to structures of Group R-2, R-3 or
does not contain a water, gas, oil or sewer connection. These structures shall b
sufficient weight to remain in place or shall be anchored to the ground. |
- |
pdf_text |
| 1 |
1, 3, 4, 5, and 6, "C," shall be deleted in reference to seismic design categories.
xxxiv. At Section 1705.13.8, Seismic isolation systems, in the first sentence of th
paragraph, "B, C" shall be deleted in reference to seismic design categories.
xxxv. Section 1705.14.1, Structural steel, Section 1705.14.1.1, Seismic force-resi
systems, and Section 1705.14.1.2, Structural steel elements shall be deleted in thei
entirety.
xxxvi. At Section 1705.14.2, Nonstructural components, in the first sentence, "B,
shall be deleted in reference to seismic design categories. Additionally, in the seco
sentence, "building official" shall be deleted and "construction official" shall be in
xxxvii. In Section 1705.14.3, Designated seismic systems, in the first sentence, "
be deleted in reference to seismic design categories. Additionally, in the second se
"building official" shall be deleted and "construction official" shall be inserted. |
- |
pdf_text |
| 1 |
1. The spirit and intent of the law are observed; |
- |
pdf_text |
| 1 |
1,250 gpm (4731 L/min.). |
- |
pdf_text |
| 1 |
1
Definitions
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 1 |
1. The adoption of subcodes of the Uniform Construction Code. |
- |
pdf_text |
| 1 |
1. Limited area sprinkler systems supplied from the domestic water system |
- |
pdf_text |
| 1 |
1. Pursuant to the authority at P.L. 1975, c. 217, as modified at P.L. 1996, c. 53, the
Commissioner hereby adopts the model code of the International Code Council, 2024
International Residential Code known as the IRC/2024 as the one- and two-family dw
subcode in New Jersey subject to the modifications stated at (c) below.
i. Copies of this code may be obtained from the International Code Council at 405
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The IRC/2024 may be known and cited as the one- and two-family dwelling su |
- |
pdf_text |
| 1 |
1. In buildings equipped throughout with an automatic sprinkler system
installed in accordance with either Section 903.3.1.1 or 903.3.1.2 and a
where the highest floor is located not more than 150 feet (45720 mm) a
lowest level of fire department vehicle access, the automatic water sup
required to exceed the requirements of NFPA 13 listed in Chapter 35. |
- |
pdf_text |
| 1 |
1. In buildings equipped throughout with an automatic sprinkler system in
accordance with either Section 903.3.1.1 or 903.3.1.2 and also where the hi
floor is located not more than 150 feet (45720 mm) above the lowest level
department vehicle access, the automatic water supply is not required to ex
requirements of NFPA 13 listed in Chapter 35. |
- |
pdf_text |
| 1 |
1. Farm or residential tanks of 1,100 gallons or less capacity used for storing motor fu
noncommercial purposes; |
- |
pdf_text |
| 1 |
1. A commercial farm building means any building located on a commercial farm whi
produces not less than $ 2,500 worth of agricultural or horticultural products annually
building's main use or intended use is related to the production of agricultural or hortic
products produced on that farm. |
- |
pdf_text |
| 1 |
1. When no mechanical inspector is assigned, the construction official shall assign the
plumbing subcode official or a plumbing inspector, who shall have the responsibility f
enforcement of provisions of the code for the installation and replacement of heating o
cooling equipment or water heaters or other mechanical equipment, such as refrigerati
conditioning, or ventilating apparatus, gas piping or heating systems, or stand-by pow
generators, except electrical, in existing buildings of Group R-3 or R-5. A plumbing s
official or plumbing inspector need not be a mechanical inspector to perform these ins
History
HISTORY:
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1986 d.380, effective September 22, 1986.
See: 18 N.J.R. 1235(a), 18 N.J.R. 1931(a), 18 N.J.R. 2063(a).
Substantially amended.
Amended by R.1987 d.14, effective January 5, 1987.
See: 18 N.J.R. 2083(a), 19 N.J.R. 63(a).
(f)4 added; old (f)4-6 renumbered (f)5-7.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
(a)1 through 4: model subcode revisions.
Amended by R.1990 d.226, effective May 7, 1990. |
- |
pdf_text |
| 1 |
1. Pursuant to authority at P.L. 1975, c. 217, as modified at P.L. 1996, c. 53, the
Commissioner hereby adopts the model code of the International Code Council, 2024
International Building Code, known as the "IBC/2024." This code is hereby adopted b
reference as the building subcode for New Jersey subject to the modifications stated at
below.
i. Copies of this code may be obtained from the International Code Council at 405
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The IBC/2024, as amended, may be known and cited as the "building subcode. |
- |
pdf_text |
| 1 |
1. Chapter 1 of the mechanical subcode, entitled "Scope and Administration," the sub
are deleted and "The applicable administrative provisions of the Uniform Construction
(N.J.A.C. 5:23) shall apply." shall be inserted under each section title, except that the
"alternative materials" section shall state "The provisions of N.J.A.C. 5:23-3.7 shall ap |
- |
pdf_text |
| 1 |
1. Pursuant to authority at P.L. 1975, c. 217, the Commissioner hereby adopts the mo
of the International Code Council, Inc., known as the International Fuel Gas Code/202
code is hereby adopted by reference as the fuel gas subcode for the State of New Jerse
to the modifications at (b) below.
i. Copies of this code may be obtained from the International Code Council, 4051
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The International Fuel Gas Code/2024 may be known and cited as the "fuel gas
subcode." |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Application, shall be amended as follows:
i. Sections C101.1, Title, and C101.3, Intent, shall be deleted.
ii. Section C101.4.1, Mixed residential and commercial buildings, and Section C1
Compliance, shall have "by means of the ASHRAE Standard 90.1" inserted after "
Commercial Provisions."
iii. Section C103, Construction Documents, Section C104, Fees, Section C105,
Inspections, Section C106, Notice of Approval, Section C107, Validity, Section C
Other laws, C109, Stop Work Order, and C110, Board of Appeals, shall be deleted |
- |
pdf_text |
| 1 |
1. Accessory garden-type utility sheds and similar structures that are 100 squa
less in area, 10 feet or less in height and does not contain a water, gas, oil or se
connection. These structures shall be of sufficient weight to remain in place or
anchored to the ground. |
- |
pdf_text |
| 1 |
1
Scope and Administration
As applicable
As applicable
(R
E)
C
h. |
- |
pdf_text |
| 1 |
1. Article 90 of the electrical subcode, entitled "Introduction," is amended as follows:
i. Section 90.4, entitled "Enforcement," is amended to delete in the first paragraph
phrase, "authority having jurisdiction for enforcement of the code" and substitute i
thereof, the term "electrical subcode official." And add a new last sentence in the f
paragraph: "Approval shall be in accordance with N.J.A.C. 5:23-2.9." Delete in the
paragraph the phrase "authority having jurisdiction" and substitute in lieu thereof t
"electrical subcode official" and add after "effective safety" the phrase "as provide
N.J.A.C. 5:23-2.9." Delete in the third paragraph the phrase "authority having juris
and substitute in lieu thereof the term "electrical subcode official" and delete the p
the jurisdiction" after the word "adopted."
ii. Section 90.5, entitled "Mandatory Rules, Permissive Rules, and Explanatory M
is amended to add "except as outlined under N.J.A.C. 5:23-3.16(a)2i" after the wor
"Code" in line 6 under paragraph (C). |
- |
pdf_text |
| 1 |
1. Chapter 1 of the fuel gas subcode, entitled "Scope and Administration," is deleted i
entirety. |
- |
pdf_text |
| 1 |
1. Under the heading of "Ground Snow Load," insert "see Bulletin 19-1"; |
- |
pdf_text |
| 1 |
1. Where only 11/2-inch valves are provided, the supply piping shall be si
minimum flow of 100 gpm (378 L/min.) for each riser, and the total shall n
required to exceed 500 gpm (1892 L/min.). |
- |
pdf_text |
| 1 |
1. The wet vent shall be not less than 1-1/2" size for a 1 DFU lavat
for 2 DFU sink. |
- |
pdf_text |
| 1 |
1. Pursuant to the authority of P.L. 1975, c. 217, as modified by P.L. 1996, c. 53, the
Commissioner hereby adopts the Model Code of the International Association of Plum
Mechanical Officials, known as "The National Standard Plumbing Code Illustrated/20
the plumbing subcode for New Jersey.
i. Copies of this code may be obtained from the sponsor at: New Jersey PHCC, 18
Bergen Place, Red Bank, NJ 07701. |
- |
pdf_text |
| 1 |
1. In section 102.2, entitled "applicability" in the first sentence shall be delete |
- |
pdf_text |
| 1 |
1. Garden-type utility sheds and similar structures that are 100 square feet or l
area, 10 feet or less in height and accessory to structures of Group R-2, R-3 or
does not contain a water, gas, oil or sewer connection. These structures shall b
sufficient weight to remain in place or shall be anchored to the ground. |
- |
pdf_text |
| 1 |
1. Pursuant to the authority of P.L. 1975, c. 217, as modified at P.L. 1996, c. 53, the
Commissioner hereby adopts the following portions of the building, electrical, mechan
fuel gas, and one- and two-family dwelling subcodes, to the extent delineated at N.J.A |
- |
pdf_text |
| 1 |
1. Names and addresses of the owners of the tent or air-supported structure. |
- |
pdf_text |
| 1 |
1. Electrical generating stations, including nuclear; |
- |
pdf_text |
| 1 |
1. The spirit and intent of the law are observed; |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Administration, shall be deleted in its entirety and
administrative provisions of N.J.A.C. 5:23." shall be inserted. In addition, a
referenced section of Chapter 1 shall be deleted throughout the code and "t
administrative provisions of the Uniform Construction Code (N.J.A.C. 5:2
be inserted. |
- |
pdf_text |
| 1 |
1. Proposals for code changes to the rehabilitation subcode (N.J.A.C. 5:23-6) may be
submitted to the Department at any time. Those rehabilitation subcode code change pr
submitted by January 31 shall be considered with the changes received during the prev
calendar year. |
- |
pdf_text |
| 1 |
1. The wet vent is 2" minimum size. |
- |
pdf_text |
| 1 |
1. A floor plan that indicates the use of all rooms. |
- |
pdf_text |
| 1 |
1. Smoke detection in habitable spaces is not required where the facility is
equipped throughout with an automatic sprinkler system installed in accord
with Section 903.3.1.1. |
- |
pdf_text |
| 1 |
1. At Section 102.2, entitled " Applicability," "adopted by the administrative a
in the first sentence shall be deleted. |
- |
pdf_text |
| 1 |
1. Are in a municipality that has an elevator subcode official; and |
- |
pdf_text |
| 1 |
1. Buildings and other structures that represent a low hazard to human life in t
of failure, including but not limited to, agricultural buildings, temporary buildi
minor storage facilities. |
- |
pdf_text |
| 1 |
1. Valves shall not be installed between the domestic water riser control valve
sprinklers.
Exception: An approved indicating control valve supervised in the open p
accordance with Section 903.4. |
- |
pdf_text |
| 1 |
1. Pursuant to the authority at P.L. 1975, c. 217, the Commissioner hereby adopts the
code of the International Code Council, Inc., known as the International Mechanical
Code/2024. This code is hereby adopted by reference as the Mechanical Subcode for t
of New Jersey subject to the modifications at (b) below.
i. Copies of this code may be obtained from the International Code Council, 4051
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The International Mechanical Code/2024 may be known and cited as the "mech
subcode." |
- |
pdf_text |
| 1 |
1. Chapter 1 of the mechanical subcode, entitled "Scope and Administration," is delet
entirety. |
- |
pdf_text |
| 1 |
1. The municipal code enforcing agency providing construction code plan approval m
to perform the review and must be appropriately classified for the proposed project in
accordance with this chapter.
i. The municipal code enforcing agency in the municipality where the proposed pr
to take place shall be given the right of first refusal to review the plans provided th
agency is appropriately classified for the proposed project in accordance with this |
- |
pdf_text |
| 1 |
1. Where only 11/2-inch valves are provided, the riser(s) shall be sized to
minimum flow of 100 gpm (378 L/min.). |
- |
pdf_text |
| 1 |
1. The wet vent is 1-1/2" minimum pipe size if the water closet ben
size, or it shall be 2" minimum pipe size if the water closet bend is
size. |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Application, shall be amended as follows:
i. Sections R101.1, Title, and R101.3, Intent, shall be deleted.
ii. Section R101.4, Compliance, and Section R102.1.1, Mixed residential and com
buildings, shall have "by means of the ASHRAE Standard 90.1" inserted after "IE
Commercial Provisions."
iii. Sections R102.2, Other laws; R102.5, Partial invalidity; R103, Code Complian
Agency; R104, Alternative Materials, Design And Methods Of Construction and
Equipment; R105, Construction Documents; R106, Fees; C107, Inspections; R108
of Approval; R109, Means of Appeals; and R110, Stop Work Order shall be delete
"The applicable administrative provisions of the Uniform Construction Code (N.J. |
- |
pdf_text |
| 1 |
1. Building Subcode:
C
ha
pt
er
Section/Title
Responsibility
Plan Review
Inspection
C
h. |
- |
pdf_text |
| 1 |
1. Each instructional space and room of assembly which is illuminated with the use of
intensity discharge (HID) sources, such as mercury vapor, high pressure sodium and
halide lamps, shall also be provided with a second source of illumination to provide
illumination instantly upon activation of the circuit. All high intensity discharge (HID)
shall be of the fail-safe type which will permanently extinguish within 15 minutes afte |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Administration, shall be deleted in its entirety and "Se
administrative provisions of N.J.A.C. 5:23." shall be inserted. In addition, any
referenced section of Chapter 1 shall be deleted throughout the code and "the
administrative provisions of the Uniform Construction Code (N.J.A.C. 5:23)" s
inserted. |
- |
pdf_text |
| 1 |
1. A field evaluation label and report or letter issued by a nationally recognized testin
laboratory verifying that the specific material, equipment, or method of construction m
identified standards or has been tested and found to be suitable for the intended use, sh
accepted by the appropriate subcode official as meeting the requirements of (a) above. |
- |
pdf_text |
| 1 |
1. Where only 11/2-inch valves are provided, the riser(s) shall be sized
provide a minimum flow of 100 gpm (378 L/min.). |
- |
pdf_text |
| 1 |
1. An elevator that provides an accessible route within an individual dwelling
shall not be required to comply with the dimensional requirements of an access
elevator. |
- |
pdf_text |
| 1 |
1. Chapter 8, Power, shall be considered optional.
ii. Sections C402, Building Thermal Envelope Requirements; C403, Building Me
Systems; C404, Service Water Heating; C405, Electrical Power and Lighting Syst
C406, Additional Efficiency, Renewable and Load Management Requirements; C
Simulated Building Performance; C408, Maintenance Information and System
Commissioning; and C409, Calculation of the HVAC Total System Performance
shall be deleted in their entirety unless referenced for compliance in an optional ap |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Administration, the subsections shall be deleted and "The ap
administrative provisions of the Uniform Construction Code (N.J.A.C. 5:23) shall app
be inserted at each section title, except that the "alternative materials" section shall stat
provisions of N.J.A.C. 5:23-3.7 shall apply.". |
- |
pdf_text |
| 1 |
1. Exception: In the case of a permit application based upon prototype plans released
Department, it shall be the responsibility of the applicant to submit the items listed at |
- |
pdf_text |
| 1 |
1. Proposals for code changes to other State-developed subcodes may be submitted to
Department at any time and shall include the information outlined in (b)2 above. |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Administration, shall be deleted in its entirety an
the administrative provisions of N.J.A.C. 5:23." shall be inserted. In additi
referenced section of Chapter 1 shall be deleted throughout the code and "t
administrative provisions of the Uniform Construction Code (N.J.A.C. 5:2
be inserted. |
- |
pdf_text |
| 1 |
1. Pursuant to authority of P.L. 1975, c. 217, the Commissioner hereby adopts the mo
of the International Code Council, Inc., known as the International Fuel Gas Code/202
code is hereby adopted by reference as the fuel gas subcode for the State of New Jerse
to the modifications at (b) below.
i. Copies of this code may be obtained from the International Code Council, 4051
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The International Fuel Gas Code/2021 may be known and cited as the "fuel gas
subcode." |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Administration, shall be deleted in its entirety and "See the
administrative provisions of N.J.A.C. 5:23." shall be inserted. In addition, any referen
section of Chapter 1 shall be deleted throughout the code and "the administrative provi
the Uniform Construction Code (N.J.A.C. 5:23)" shall be inserted. |
- |
pdf_text |
| 1 |
1. Smoke detection in habitable spaces is not required where the facility
equipped throughout with an automatic sprinkler system installed in accor
with Section 903.3.1.1. |
- |
pdf_text |
| 1 |
1. Any private party, municipality, other political subdivision, or agency of the State s
to submit a State-sponsored model code change proposal shall do so not less than 240
prior to the code change meeting of the model code adoption agency for which the am
is being proposed. |
- |
pdf_text |
| 1 |
1, substituted a reference to the building subcode for a reference to BOCA/96 section 918.5 in 2 a
substituted a reference to the mechanical subcode for a reference to the BOCA National Mechani
in 4.
Administrative correction.
See: 41 N.J.R. 2648(a).
Amended by R.2013 d.081, effective June 3, 2013.
See: 44 N.J.R. 1303(a), 45 N.J.R. 1393(a).
Rewrote the introductory paragraph of (a); deleted (a)1 through (a)5; deleted (c)1 through (c)2;
recodified former (c)3 and (c)4 as (c)1 and (c)2; and in (d), substituted "6.3, 6.4, and 8.1" for "6.2
Amended by R.2015 d.029, effective February 17, 2015.
See: 46 N.J.R. 1507(a), 47 N.J.R. 459(a).
Added (a)1; and in the introductory paragraph of (b), deleted ", upon notice to and approval by t
Department," following "district".
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law |
- |
pdf_text |
| 1 |
1
Definitions
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 1 |
1, substituted a reference to the building subcode for a reference to BOCA/96 section 918.5 in 2 a
substituted a reference to the mechanical subcode for a reference to the BOCA National Mechani
in 4.
Administrative correction.
See: 41 N.J.R. 2648(a).
Amended by R.2013 d.081, effective June 3, 2013.
See: 44 N.J.R. 1303(a), 45 N.J.R. 1393(a).
Rewrote the introductory paragraph of (a); deleted (a)1 through (a)5; deleted (c)1 through (c)2;
recodified former (c)3 and (c)4 as (c)1 and (c)2; and in (d), substituted "6.3, 6.4, and 8.1" for "6.2
Amended by R.2015 d.029, effective February 17, 2015.
See: 46 N.J.R. 1507(a), 47 N.J.R. 459(a).
Added (a)1; and in the introductory paragraph of (b), deleted ", upon notice to and approval by t
Department," following "district".
Annotations
Notes |
- |
pdf_text |
| 1 |
1. Buildings equipped throughout with automatic sprinkler systems install
accordance with Section 903.3.1.1. |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Application, shall be amended as follows:
i. Sections R101.1, Title, and R101.3, Intent, shall be deleted.
ii. Section R101.4.1, Mixed residential and commercial buildings, and Section R1
Compliance, shall have "by means of the ASHRAE Standard 90.1" inserted after "
Commercial Provisions."
iii. Section R103, Construction Documents, Section R104, Fees, Section R105,
Inspections, Section R106, Notice of Approval, Section R107, Validity, Section R
Other laws, R109, Stop Work Order, and R110, Means of Appeal, shall be deleted. |
- |
pdf_text |
| 1 |
1. Exception: Where enforcement of a code provision would violate the condition(s) o
listing of the equipment or appliance, the more restrictive condition(s) shall apply.
History
HISTORY:
New Rule, R.1988 d.283, effective June 20, 1988.
See: 20 N.J.R. 699(a), 20 N.J.R. 1343(c).
Old text repealed and new text substituted.
Amended by R.1998 d.28, effective January 5, 1998.
See: 29 N.J.R. 3603(a), 30 N.J.R. 129(a). |
- |
pdf_text |
| 1 |
1,250 gpm (4731 L/min.).
Exceptions |
- |
pdf_text |
| 1 |
1. Where only 11/2-inch valves are provided, the supply piping shall be
for a minimum flow of 100 gpm (378 L/min.) for each riser, and the tot
not be required to exceed 500 gpm (1892 L/min.). |
- |
pdf_text |
| 1 |
1. Amusement rides and any portable generator and associated portable distribution w
that serves portable amusement rides, portable concessions, portable ticket booths, and
portable structures that are ancillary in nature at carnivals and fairs; |
- |
pdf_text |
| 1 |
1. Construction or rehabilitation of health care facilities shall be in accordance with th
and with the "Guidelines for Design and Construction of Health Care Facilities" (Facil
Guidelines Institute), current edition. All health care facilities shall comply with Natio
Protection Association (NFPA) 101, the Life Safety Code, as referenced in the rules
promulgated by the Centers for Medicare and Medicaid Services. In the event of any c
the more restrictive code provision shall govern. |
- |
pdf_text |
| 1 |
1. Pursuant to the authority at P.L. 1975, c. 217, as modified at P.L. 1996, c. 53, the
Commissioner hereby adopts the model code of the National Fire Protection Associati
known as "The National Electrical Code (NEC) 2023," and Tentative Interim Amend |
- |
pdf_text |
| 1 |
1. Chapter 1, Scope and Administration, the subsections shall be deleted and "The ap
administrative provisions of the Uniform Construction Code (N.J.A.C. 5:23) shall app
be inserted at each section title, except that the "alternative materials" section shall stat
provisions of N.J.A.C. 5:23-3.7 shall apply." |
- |
pdf_text |
| 1 |
1. Limited area sprinkler systems supplied from the domestic water system. |
- |
pdf_text |
| 1 |
1. The section entitled "Administration," comprising sections ADM 1.1 through ADM
deleted in its entirety. |
- |
pdf_text |
| 1 |
1. Pursuant to authority at P.L. 1975, c. 217, as modified at P.L. 1996, c. 53, the
Commissioner hereby adopts the model code of the International Code Council, know
International Energy Conservation Code/2024 (IECC/2024), as the energy subcode for
Jersey.
i. Copies of the IECC/2024 may be obtained from International Code Council, 40
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The model code listed above may be known and cited as the "energy subcode."
(b) The following chapters and sections of the commercial provisions of the energy subco
amended, as follows: |
- |
pdf_text |
| 1 |
1. Pursuant to authority of P.L. 1975, c. 217, as modified by P.L. 1996, c. 53, the
Commissioner hereby adopts the model code of the International Code Council, know
International Energy Conservation Code/2021 (IECC/2021), as the energy subcode for
Jersey.
i. Copies of the IECC/2021 may be obtained from International Code Council, 40
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The model code listed above may be known and cited as the "energy subcode."
(b) The following chapters and sections of the commercial provisions of the energy subco
amended, as follows: |
- |
pdf_text |
| 1 |
1. The emblem shall be of a bright and reflective color, or made of reflective material.
shape of the emblem shall be an isosceles triangle and the size shall be 12 inches horiz
by six inches vertically. The following letters, of a size and color to make them conspi
shall be printed on the emblem:
i. "F" to signify a floor with truss construction;
ii. "R" to signify a roof with truss construction; or
iii. "F/R" to signify both a floor and roof with truss construction. |
- |
pdf_text |
| 1 |
1. Pursuant to authority of P.L. 1975, c. 217, as modified by P.L. 1996, c. 53, the
Commissioner hereby adopts the model code of the International Code Council, 2021
International Building Code, known as the "IBC/2021." This code is hereby adopted b
reference as the building subcode for New Jersey subject to the modifications stated at
below.
i. Copies of this code may be obtained from the International Code Council at 405
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The IBC/2021, as amended, may be known and cited as the "building subcode. |
- |
pdf_text |
| 1 |
1. Building Subcode:
Cha
pter
Section/Title
Responsibility
Inspection
Plan Review
Ch. |
- |
pdf_text |
| 1 |
1. Applications, certificates and permits: Such official(s) shall review applications for
for the erection, repair (other than ordinary maintenance), renovation, alteration and
reconstruction of buildings and structures; indicate approval or denial to the constructi
official; and inspect the premises for which such permits have been issued and enforce
compliance with the provisions of the regulations. |
- |
pdf_text |
| 1 |
1. Buildings equipped throughout with automatic sprinkler systems installe
accordance with Section 903.3.1.1. |
- |
pdf_text |
| 1 |
1. Pursuant to authority of P.L. 1975, c. 217, the Commissioner hereby adopts the mo
of the International Code Council, Inc., known as the International Mechanical Code/2
This code is hereby adopted by reference as the Mechanical Subcode for the State of
Jersey subject to the modifications at (b) below.
i. Copies of this code may be obtained from the International Code Council, 4051
Flossmoor Road, Country Club Hills, Illinois 60478-5795.
ii. The International Mechanical Code/2021 may be known and cited as the "mech
subcode." |
- |
pdf_text |
| 1 |
1. Chapter 8, Power, shall be considered optional.
ii. Section C402, Building Envelope Requirements, Section C403, Building Mech
Systems, Section C404, Service Water Heating (Mandatory), Section C405, Electr
Power and Lighting Systems, Section C406, Additional Efficiency Package Optio
Total Building Performance, and C408, Maintenance Information and System
Commissioning, shall be deleted in their entirety. |
- |
pdf_text |
| 1 |
1. When no mechanical inspector is assigned, the construction official shall assign th
plumbing subcode official or a plumbing inspector, who shall have the responsibility f
enforcement of provisions of the code for the installation and replacement of heating o
cooling equipment or water heaters or other mechanical equipment, such as refrigerati
conditioning, or ventilating apparatus, gas piping or heating systems, or stand-by pow
generators, except electrical, in existing buildings of Group R-3 or R-5. A plumbing s
official or plumbing inspector need not be a mechanical inspector to perform these ins
History
HISTORY:
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d). |
- |
pdf_text |
| 10 |
10. In Section 504.5, entitled "Nosings," at items 2 and 3, "1/2 inch (13 mm)"
deleted and "9/16 inch (14.3 mm)" shall be inserted in its place. In addition, at
"1 1/2 inches (38 mm)" shall be deleted and "1 1/4 inches (32 mm)" shall be in
its place. |
- |
pdf_text |
| 10 |
10. Voltage drop calculations. |
- |
pdf_text |
| 10 |
10,200 square feet in area per floor.
R300.4.1 Increases in height. Buildings of VA construction greater tha
stories in height shall be designed and constructed in accordance with t
building subcode.
R300.4.2 Increases in Area. Buildings of VA construction shall be per
be increased in area in accordance with R300.3.
R300.5 Buildings of other types of construction. The height and area limit
allowable for buildings of construction type VA shall apply to other constr
types, as they are defined in Section 602 of the building subcode, provided
fire ratings of building elements meet or exceed the requirements for type
Tables 601 and 705.5 of the building subcode." |
- |
pdf_text |
| 10 |
10. Any pipes, lines, fixtures, or other equipment connected to any tank exempted fro
provisions of N.J.A.C. 7:14B as set forth in (b)1 to 9 above.
History
HISTORY:
New Rule, R.1990 d.562, effective November 19, 1990.
See: 22 New Jersey Register 2629(c), 22 New Jersey Register 3482(d).
Amended by R.1997 d.409, effective October 6, 1997.
See: 29 New Jersey Register 2736(a), 29 New Jersey Register 4281(a).
In (d)3, deleted maximum capacity for tanks of 2000 gallons.
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 New Jersey Register 1377(a), 30 New Jersey Register 2421(b). |
- |
pdf_text |
| 10 |
10
Means of Egress |
- |
pdf_text |
| 10 |
10
Chimneys and
Building/Fire
Building
Fireplaces
Ch. |
- |
pdf_text |
| 10 |
10. Prototype plans intended for use in more than one municipality; |
- |
pdf_text |
| 10 |
10. Chapter 12 of the plumbing subcode, entitled "Vents and Venting," shall be amen
follows:
i. Section 12.5, Frost Closure, is deleted in its entirety.
ii. Section 12.8.2, Provision for Venting Future Fixtures, is deleted in its entirety. |
- |
pdf_text |
| 10 |
10. Appendix C of the fuel gas subcode, entitled "Recommended Procedure for Safet
Inspection of an Existing Appliance Installation," is deleted in its entirety. |
- |
pdf_text |
| 10 |
10. Under the heading of "Ice Barrier Underlayment Required," insert "see Bu |
- |
pdf_text |
| 10 |
10. Chapter 11, Energy Efficiency, shall be amended as follows:
i. Sections N1101.2 (R101.3), Intent, and N1101.5 (R103.2), Information on const
documents, shall be deleted.
ii. In Section N1101.6 (R202), Defined terms, the following definitions shall be d
Addition, Alteration, Building, Historic Building, Repair, Reroofing, Residential B
Roof Recover, Roof Repair, and Roof Replacement.
iii. Section N1101.12 (R303.3), Maintenance information, shall be deleted.
iv. In Section N1101.13 (R401.2), Application, the exception shall be deleted in it
entirety.
v. In Section N1103.7 (R403.7), Equipment sizing and efficiency rating, "or repla
shall be deleted in the second sentence.
vi. In Section N1103.8 (R403.8), Systems serving multiple dwellings units, delete
"Sections C403 and C404 of the IECC--Commercial Provisions" and replace with
"Chapters 6 and 7 of the ASHRAE Standard 90.1 referenced by the energy subcod
(N.J.A.C. 5:23-3.18)."
vii. In Section N1104.1.1 (R404.1.1), Exterior lighting, delete "Section C405.5 of
International Energy Conservation Code--Commercial Provision" and replace with
"Section 9.4.2 of the ASHRAE Standard 90.1".
viii. Sections N1109 (R501), Existing Buildings--General, N1110 (R502), Additio
N1111 (R503), Alterations, N1112 (R504), Repairs, and N1113 (R505), Change o
Occupancy or Use, shall be deleted. |
- |
pdf_text |
| 10 |
10. Chapter 11, Accessibility, shall be amended as follows:
i. In the user notes, under About this Chapter, "in the International Existing Buildi
Code" shall be deleted, and "within the Rehabilitation Subcode, N.J.A.C. 5:23-6" s
inserted.
ii. In Section 1101.1, Scope, insert the following after the first sentence: "This cha
shall be interpreted to require access for people with disabilities, including, but not
to occupants, employees, consumers, students, spectators, participants, or visitors."
iii. Insert Section 1101.2 as follows: |
- |
pdf_text |
| 10 |
10
Boilers, Water Heaters
Plumbing
Plumbing
and Pressure Vessels
Ch. |
- |
pdf_text |
| 10 |
10
Fireplaces
Ch.
Energy |
- |
pdf_text |
| 10 |
10. Chapter 12 of the mechanical subcode, entitled "Hydronic Piping," is amended as
i. In Section 1210.8.1, Protection of potable water, "International Plumbing Code,
be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 10 |
10,200 square feet in area per floor.
R300.4.1 Increases in height. Buildings of VA construction greater than th
stories in height shall be designed and constructed in accordance with the b
subcode.
R300.4.2 Increases in Area. Buildings of VA construction shall be permitt
increased in area in accordance with R300.3.
R300.5 Buildings of other types of construction. The height and area limit
allowable for buildings of construction type VA shall apply to other constr
types, as they are defined in Section 602 of the building subcode, provided
fire ratings of building elements meet or exceed the requirements for type
Tables 601 and 705.5 of the building subcode."
ii. Table R301.2, Climatic and Geographic Design Criteria, shall be amended as f |
- |
pdf_text |
| 10 |
10. Chapter 12 of the plumbing subcode, entitled "Vents and Venting," shall be amen
follows:
i. Section 12.5, Frost Closure, is deleted in its entirety.
ii. Section 12.8.2, Provision for Venting Future Fixtures, is deleted in its entirety.
iii. Section 12.10, Wet Venting, shall be deleted and the text of the 2015 National
Plumbing Code shall be inserted: |
- |
pdf_text |
| 10 |
10
Boilers, Water Heaters
Plumbing
Plumbing
and Pressure Vessels
Ch. |
- |
pdf_text |
| 10 |
10. Informative Annex H of the electrical subcode, entitled "Administration and
Enforcement," is deleted in its entirety.
History
HISTORY:
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1984 d.314, effective August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b).
Section substantially amended.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
Amendments to (b)4i(2), ii(2).
Administrative Correction to (b)4i(2).
See: 22 N.J.R. 2503(b).
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1993 d.662, effective December 20, 1993. |
- |
pdf_text |
| 10 |
10. Chapter 11, Accessibility, shall be amended as follows:
i. In Section 1101.1, Scope, insert the following after the first sentence: "This cha
be interpreted to require access for people with disabilities, including, but not limit
occupants, employees, consumers, students, spectators, participants, or visitors."
ii. Insert Section 1101.2 as follows:
"1101.2 Existing facilities. Any building or portion of a building constructed
to be accessible shall be maintained accessible." |
- |
pdf_text |
| 10 |
10. Chapter 13 of the mechanical subcode, entitled "Fuel Oil Piping And Storage," is
as follows:
i. Section 1301.2, Storage and piping systems, is amended to add the following se
"Where the tank is of a size and type that is subject to the Department of Environm
Protection rules for the installation of Underground Storage Tanks at N.J.A.C. 7:1
rules shall apply." |
- |
pdf_text |
| 10 |
10
Other Equipment
As applicable except
As applicable except
as below:
as below: |
- |
pdf_text |
| 10 |
10
Other Equipment |
- |
pdf_text |
| 10 |
10. A commercial farm building may include a use that does not meet the definition o
"commercial farm building," provided that the space that does not meet the commercia
building definition is separate from the remainder of the building with the required fir
separation assemblies and meets all applicable requirements of the building subcode. |
- |
pdf_text |
| 10 |
10. Chapter 11, Energy Efficiency, shall be amended as follows:
i. Sections N1101.2 (R101.3), Intent, and N1101.5 (R103.2), Information on const
documents, shall be deleted.
ii. At Section N1101.6 (R202), Defined terms, the following definitions shall be d
Addition, Alteration, Building, Construction Documents, Existing Building, Histor
Building, Repair, Reroofing, Residential Building, Roof Recover, Roof Repair, Ro
Replacement, Substantial Improvement, and Work Area.
iii. Section N1101.12 (R303.3), Maintenance information, shall be deleted.
iv. In Section N1101.13 (R401.2), Application, the exception shall be deleted in it
entirety.
v. In Section N1103.7 (R403.7), Equipment sizing and efficiency rating, "or repla
shall be deleted in the second sentence.
vi. In Section N1103.8 (R403.8), Systems serving multiple dwellings units, delete
"Sections C403 and C404 of the IECC--Commercial Provisions" and replace with |
- |
pdf_text |
| 10 |
10. Appendix D of the fuel gas subcode, entitled "Recommended Procedure for Safet
Inspection of an Existing Appliance Installation," is deleted in its entirety. |
- |
pdf_text |
| 10.4.1 |
10.4.1
Electrical
Electrical |
- |
pdf_text |
| 10.4.1 |
10.4.1
Electrical
Electrical |
- |
pdf_text |
| 10.4.2 |
10.4.2
Plumbing
Plumbing |
- |
pdf_text |
| 10.4.2 |
10.4.2
Plumbing
Plumbing |
- |
pdf_text |
| 10.4.3-10.4.4 |
10.4.3-10.4.4
Elevator
Elevator |
- |
pdf_text |
| 10.4.3-10.4.4 |
10.4.3-10.4.4
Elevator
Elevator |
- |
pdf_text |
| 10.4.5 |
10.4.5
Building
Building |
- |
pdf_text |
| 10.4.5 |
10.4.5
Building
Building |
- |
pdf_text |
| 10.4.7 |
10.4.7
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 10.4.8 |
10.4.8
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 10.5.9 |
10.5.9
Fire/Pl
umbing
Plumbing
(except dedicated
fire service
supply) Fire
(dedicated fire
service supply)
C
h.
Sanitary Drainage Systems
Plumbi
ng
Plumbing |
- |
pdf_text |
| 10.5.9 |
10.5.9
Fire/Pl
umbing
Plumbing
(except dedicated
fire service
supply) Fire
(dedicated fire
service supply)
C
h.
Sanitary Drainage Systems
Plumbi
ng
Plumbing |
- |
pdf_text |
| 100 |
100 joints or gaskets, regardless of pipe diameter.
(2) The amount of leakage in accordance with (1) above shall be permitted to
increased in increments of 1 fluid ounce (30 ml) per inch valve diameter per ho
each metal seated valve that isolates the test section.
(3) The amount of leakage in buried piping shall be measured at the test press
specified by pumping from a calibrated container.
iii. Add new Section 15.9 as follows: 15.9 Flushing of Piping: Lead-in connection
system risers and fire service mains from the water supply to the system riser (excl
limited systems) shall be flushed completely before connection is made to sprinkle
The flushing operation shall be continued for a sufficient amount of time to ensure
system is thoroughly cleaned. The minimum rate of flow shall be not less than one
following: |
- |
pdf_text |
| 100 |
100 joints or gaskets, regardless of pipe diameter.
(2) The amount of leakage in accordance with (1) above shall be permitted to
increased in increments of 1 fluid ounce (30 ml) per inch valve diameter per ho
each metal seated valve that isolates the test section.
(3) The amount of leakage in buried piping shall be measured at the test press
specified by pumping from a calibrated container.
iii. Add new Section 15.9 as follows: 15.9 Flushing of Piping: Lead-in connection
system risers and fire service mains from the water supply to the system riser (excl
limited systems) shall be flushed completely before connection is made to sprinkle
The flushing operation shall be continued for a sufficient amount of time to ensure
system is thoroughly cleaned. The minimum rate of flow shall be not less than one
following:
(1) The hydraulically calculated water demand rate of the system, including a
requirements.
(2) The flow that is necessary to provide a velocity of 10 ft/sec (3.1 m/sec).
(3) The maximum flow rate available to the system under fire conditions. |
- |
pdf_text |
| 100 |
100), only products listed, labeled, approved, and identified are acceptable. Appro
be based on tests and listings of testing laboratories such as Underwriters Laborato
(UL), Factory Mutual (FM), or Canadian Standards Association (CSA), etc. Marki
applied to products by such testing laboratories shall indicate the approval is based
applicable US standards. |
- |
pdf_text |
| 100 |
100 REM sealed |
- |
pdf_text |
| 1001-1007 |
1001-1007, except
Building/Fire
Building |
- |
pdf_text |
| 1001-1007 |
1001-1007, except 1006.2.2.4
Building/Fire
Building |
- |
pdf_text |
| 1005.3.6 |
1005.3.6," following "stairway" and substituted "1023" for "1003.3.4"; in the introductory paragr
(b)9vi, substituted "903.2.14" for "903.2.16"; in (b)9xii3, substituted "903.3.1.1" for "906.2.1"; re
(b)9xiii through (b)9xli; added (b)9xlii; rewrote (b)10, (b)17xiv through (b)17xxii; added new (b)
recodified former (b)18v through (b)18xi as (b)18vi through (b)18xii; rewrote (b)21; and in (b)22
deleted "In" preceding "Section" and "Item 3" preceding "shall".
Amended by R.2009 d.126, effective April 20, 2009.
See: 41 N.J.R. 16(a), 41 N.J.R. 1725(a).
Added new (b)18v; and recodified former (b)18v through (b)18xii as (b)18vi through (b)18xiii.
Amended by R.2009 d.255, effective August 17, 2009.
See: 41 N.J.R. 1919(a), 41 N.J.R. 3065(a).
In (b)21ii, inserted "insert" twice, substituted "8.6" for "8.6.1.6.5" and deleted "shall be inserted"
preceding "after" twice.
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote the section.
Amended by R.2012 d.179, effective November 5, 2012.
See: 44 N.J.R. 1679(a), 44 N.J.R. 2557(a). |
- |
pdf_text |
| 1005.3.6 |
1005.3.6," following "stairway" and substituted "1023" for "1003.3.4"; in the introductory paragr
(b)9vi, substituted "903.2.14" for "903.2.16"; in (b)9xii3, substituted "903.3.1.1" for "906.2.1"; re
(b)9xiii through (b)9xli; added (b)9xlii; rewrote (b)10, (b)17xiv through (b)17xxii; added new (b)
recodified former (b)18v through (b)18xi as (b)18vi through (b)18xii; rewrote (b)21; and in (b)22
deleted "In" preceding "Section" and "Item 3" preceding "shall".
Amended by R.2009 d.126, effective April 20, 2009.
See: 41 N.J.R. 16(a), 41 N.J.R. 1725(a).
Added new (b)18v; and recodified former (b)18v through (b)18xii as (b)18vi through (b)18xiii.
Amended by R.2009 d.255, effective August 17, 2009.
See: 41 N.J.R. 1919(a), 41 N.J.R. 3065(a). |
- |
pdf_text |
| 1006.2.2.4 |
1006.2.2.4
Building/Electri
cal/Fire
Building |
- |
pdf_text |
| 1008 |
1008
Building/Electri
cal/Fire
Electrical for wiring and
function/Building for
placement |
- |
pdf_text |
| 1008 |
1008
Building/Electri
cal/Fire
Electrical for wiring and
function/Building for
placement |
- |
pdf_text |
| 1008 |
1008 of the building subcode.
ii. The use of a commercial farm building as a "special amusement building," as d
the building subcode, shall be permitted only if a permit specific to special amuse
buildings is issued by the local fire official pursuant to the Uniform Fire Safety Ac
N.J.S.A. 52:27D-192 et seq. or if the building or portion thereof complies with N.J |
- |
pdf_text |
| 1009 |
1009
Building
Building |
- |
pdf_text |
| 1009-1009.4 |
1009-1009.4
Building/Fire
Building |
- |
pdf_text |
| 1009-1009.4 |
1009-1009.4
Building/Fire
Building |
- |
pdf_text |
| 1009.4.1 |
1009.4.1
Electrical/Eleva
tor
Electrical/Elevator |
- |
pdf_text |
| 1009.4.1 |
1009.4.1
Electrical/Eleva
Electrical for |
- |
pdf_text |
| 1009.4.2-1010.2.8.1 |
1009.4.2-1010.2.8.1
Building/Fire
Building |
- |
pdf_text |
| 1009.4.2-1010.2.9.1 |
1009.4.2-1010.2.9.1
Building/Fire
Building |
- |
pdf_text |
| 101.2 |
101.2."
ii. In Section 301.3, Listed and labeled, "in accordance with Section 105," shall be
In addition, the second sentence shall be deleted in its entirety. |
- |
pdf_text |
| 101.2 |
101.2."
ii. In Section 301.3, Listed and labeled, "in accordance with Section 105," shall be
In addition, the second sentence shall be deleted in its entirety.
iii. In Section 301.6, Plumbing connections, "International Plumbing Code," shall
deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)," shall be inserted.
iv. Section 301.9, Repair, is deleted.
v. Section 305.1, General, delete the second paragraph in its entirety. |
- |
pdf_text |
| 101.2 |
101.2."
ii. Section 301.7, Listed and labeled, is amended to delete the words "in accordan |
- |
pdf_text |
| 1010.2.8.2 |
1010.2.8.2
Building/Electri
cal/Fire
Building |
- |
pdf_text |
| 1010.2.8.3-1012 |
1010.2.8.3-1012
Building/Fire
Building |
- |
pdf_text |
| 1010.2.9.2 |
1010.2.9.2
Building/Electri
cal/Fire
Building |
- |
pdf_text |
| 1010.2.9.3-1012 |
1010.2.9.3-1012
Building/Fire
Building |
- |
pdf_text |
| 1013 |
1013
Electrical/Fire
Electrical for wiring and
function/Fire for placement |
- |
pdf_text |
| 1013 |
1013
Electrical/Fire
Electrical for wiring and
function/Fire for placement |
- |
pdf_text |
| 1014-1031 |
1014-1031
Building/Fire
Building
Ch. |
- |
pdf_text |
| 1014-1031 |
1014-1031
Building/Fire
Building
C
h.
Accessibility
Building,
Building, except 1102 |
- |
pdf_text |
| 102.7.1 |
102.7.1" shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)"
inserted. |
- |
pdf_text |
| 102.7.1 |
102.7.1" shall be deleted and "plumbing subcode (N.J.A.C. 5:23- 3.15)
inserted. |
- |
pdf_text |
| 102.7.1 |
102.7.1" shall be deleted. |
- |
pdf_text |
| 107.1 |
107.1" shall be deleted.
xiv. At Section 1704.2.4, Report requirement, in the second, fifth, and last senten
"building official" shall be deleted and "construction official" shall be inserted.
Additionally, in the second and the fifth sentences, "registered design professional
deleted and "person" shall be inserted.
xv. At Section 1704.2.5.1, Fabricator approval, in the second and third sentence,
official" shall be deleted and "construction official" shall be inserted.
xvi. In Section 1704.3, Statement of special inspections, "registered design profes
shall be deleted and "person" shall be inserted. Additionally, the exception shall be |
- |
pdf_text |
| 107.1 |
107.1" shall be deleted.
xv. In Section 1704.2.4, Report requirements, in the second and last sentences, "b
official" shall be deleted and "construction official" shall be inserted. Additionally,
second and the fifth sentences, "registered design professional" shall be deleted an
"person" shall be inserted.
xvi. In Section 1704.2.5.1, Fabricator approval, in the third sentence, "building off
shall be deleted and "construction official" shall be inserted.
xvii. In Section 1704.3, Statement of special inspections, "registered design profes
shall be deleted and "person" shall be inserted. Additionally, the exception shall be
xviii. In Section 1704.4, Contractor responsibility, in the first sentence, "main - wi
shall be deleted. In addition, in the same sentence, "or a wind-" shall be deleted. |
- |
pdf_text |
| 1074 |
1074, 2009 N.J. Super. LEXIS 124 (App.Div. 2009).
Set back provisions of borough zoning ordinance controlled conflicting state building code pr
Pfeuffer v. Sculco, 242 N.J.Super. 181, 576 A.2d 309 (A.D.1990).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| 11 |
11
Efficiency
N1101.1-N1101.5.1
As applicable
As applicable
N1101.7-N1101.12
Building
Building
N1101.13-N1101.14
Building
Building
N1102.1-N1102.4.4
Building
Building
N1102.4.5-N1102.4.6
Electrical
Electrical |
- |
pdf_text |
| 11 |
11. Construction type, height, and allowable area requirements for commercial farm b
and structures shall be as specified in the building subcode and shall not exceed the ar
height limitations at Tables 504.3, 504.4, and 506.2 for the type of construction used,
follows:
i. The height and area of a one-story commercial farm building of any type of con
shall not be limited if the building has a fire separation distance of 50 feet. In that
sprinkler system shall not be required.
ii. The height and area of a two-story commercial farm building of any type of
construction shall not be limited if the building is provided with an approved auto
suppression system throughout, conforming to the Uniform Construction Code and
fire separation distance of 50 feet.
iii. Two or more commercial farm buildings excepted pursuant to (d)11i and ii ab
be constructed on the same lot, or on an owner's contiguous lots without meeting t
separation distance of 50 feet. However, the fire separation distance specified at T |
- |
pdf_text |
| 11 |
11. Chapter 12, Interior Environment, shall be amended as follows:
i. Section 1203, Temperature Control, shall be deleted in its entirety.
ii. Section 1207, Enhanced Classroom Acoustics, shall be deleted in its entirety.
iii. In Section 1208.2, Minimum ceiling heights, "7 feet 6 inches (2286mm)" shal
deleted and "7 feet (2134 mm)" shall be inserted in its place.
iv. At Section 1208.5, Efficiency dwelling units, in item 3, "and Type B" shall be
and "and" shall be inserted between "Accessible unit" and "Type A unit".
v. Sections 1210.3, Privacy, 1210.3.1 Water closet compartment, and 1210.3.2, U
partitions shall be deleted in their entirety. |
- |
pdf_text |
| 11 |
11. Chapter 13 of the plumbing subcode, entitled "Storm Water Drainage," shall be a
as follows:
i. In Section 13.1.5, Foundation Drains, Notes a. through d. shall be deleted and th
following shall be inserted: "a. Foundation drains shall be provided in accordance
building subcode."
ii. Section 13.1.10.1, Primary Roof Drainage, shall be amended to delete the last s
and the reference to "(See Appendix A)" and to substitute in lieu thereof "Rainfall
shall be applied so that the applicable rainfall rate for Burlington and Ocean counti
all counties south shall be six inches per hour and for Mercer and Monmouth coun
all counties north, the applicable rainfall rate shall be five inches per hour."
iii. Section 13.1.10.2, "Secondary Roof Drainage," shall be amended as follows:
(1) Within the title and throughout the subsections, "secondary" shall be delete
"overflow" shall be inserted in its place.
(2) At subsection a., "independent secondary" shall be deleted and "overflow"
inserted. In addition, "Secondary roof drainage shall be sized for a 100-year, 1
storm. See Appendix A." shall be deleted.
(3) Subsection b. shall be deleted and the following shall be inserted: "Where
drainage is provided by means of roof drains or standpipe, the overflow system
permitted to connect to the primary roof drainage system." |
- |
pdf_text |
| 11 |
11. Under the heading of "Flood Hazards," insert "LFPA" for local floodplain
administrator; |
- |
pdf_text |
| 11 |
11. High level alarm systems in terminals, as defined in N.J.S.A. 52:27D-214; and |
- |
pdf_text |
| 11 |
11. Chapter 15 of the mechanical subcode, entitled "Referenced Standards," shall be a
as follows:
i. At the heading "ASHRAE," amend the following title: |
- |
pdf_text |
| 11 |
11. Chapter 12, Interior Environment, shall be amended as follows:
i. Section 1203, Temperature Control, shall be deleted in its entirety.
ii. Section 1207, Enhanced Classroom Acoustics, shall be deleted in its entirety.
iii. In Section 1208.2, Minimum ceiling heights, "7 feet 6 inches (2286mm)" shall
deleted and "7 feet (2134 mm)" shall be inserted in its place.
iv. In Section 1208.4, Efficiency dwelling units, in exception 3, "and Type B" sha
deleted.
v. Sections 1210.3, Privacy, 1210.3.1 Water closet compartment, and 1210.3.2, U
partitions shall be deleted in their entirety. |
- |
pdf_text |
| 11 |
11. Chapter 12, Mechanical Administration, shall be amended as follows:
i. Section M1202, Existing mechanical systems, shall be deleted in its entirety. |
- |
pdf_text |
| 11 |
11. Chapter 13 of the plumbing subcode, entitled "Storm Water Drainage," shall be a
as follows:
i. In Section 13.1.5, Foundation Drains, Notes a. through d. shall be deleted and th
following shall be inserted: "a. Foundation drains shall be provided in accordance
building subcode."
ii. Section 13.1.10.1, Primary Roof Drainage, shall be amended to delete the last s
and the reference to "(See Appendix A)" and to substitute in lieu thereof "Rainfall
shall be applied so that the applicable rainfall rate for Burlington and Ocean counti
all counties south shall be six inches per hour and for Mercer and Monmouth coun
all counties north, the applicable rainfall rate shall be five inches per hour."
iii. Section 13.1.10.2, "Secondary Roof Drainage," shall be amended as follows:
(1) Within the title and throughout the subsections, "secondary" shall be delete
"overflow" shall be inserted in its place.
(2) At subsection a., "independent secondary" shall be deleted and "overflow"
inserted. In addition, "Secondary roof drainage shall be sized for a 100-year, 1
storm. See Appendix A." shall be deleted.
(3) Subsection b. shall be deleted and the following shall be inserted: "Where
drainage is provided by means of roof drains or standpipe, the overflow system
permitted to connect to the primary roof drainage system."
(4) Subsection c. "secondary" shall be deleted and "overflow" shall be inserted
first and sixth sentences.
(5) At subsection d, "(See Appendix A)." sh |
- |
pdf_text |
| 11 |
11
Accessibility, except
Building
Building
that 1110.15, which deals
with controls, shall be
the responsibility of the
person responsible for
the control in the
general sections of the
code |
- |
pdf_text |
| 11 |
11
Additional
As applicable
As applicable
Efficiency
Requirements
Ch. |
- |
pdf_text |
| 11 |
11. Delete section 607.8, entitled "Water Temperature," in its entirety. |
- |
pdf_text |
| 11 |
11. Chapter 13 of the mechanical subcode, entitled "Fuel Oil Piping And Storage," is
as follows:
i. Section 1301.2, Storage and piping systems, is amended to add the following se
"Where the tank is of a size and type that is subject to the Department of Environm
Protection rules for the installation of Underground Storage Tanks at N.J.A.C. 7:1
rules shall apply." |
- |
pdf_text |
| 11 |
11
Energy Cost Budget
As applicable
As applicable
Method
App
x.
Solar-Ready
As applicable
As applicable
CB
Zone--Commercial
App
x.C
C
Zero Energy
As applicable
As applicable
Commercial Building
Provisions |
- |
pdf_text |
| 11 |
11. Appendix E of the fuel gas subcode, entitled "Board of Appeals," is deleted in its
History
HISTORY:
New Rule, R.2001 d.196, effective June 18, 2001.
See: 33 N.J.R. 6(a), 33 N.J.R. 2090(a).
Administrative correction.
See: 33 N.J.R. 3310(a).
Amended by R.2004 d.468, effective December 20, 2004.
See: 36 N.J.R. 1858(b), 36 N.J.R. 5711(a).
In (b), added a new 4i and recodified existing i through ii as ii through iii.
Amended by R.2005 d.35, effective January 18, 2005.
See: 36 N.J.R. 3329(b), 37 N.J.R. 267(a).
Rewrote the section.
Administrative correction.
See: 37 N.J.R. 885(a).
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
Rewrote the section.
Administrative correction.
See: 40 N.J.R. 1829(a).
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a). |
- |
pdf_text |
| 11 |
11. Appendix D of the fuel gas subcode, entitled "Board of Appeals," is deleted in its
History
HISTORY:
New Rule, R.2001 d.196, effective June 18, 2001.
See: 33 N.J.R. 6(a), 33 N.J.R. 2090(a).
Administrative correction.
See: 33 N.J.R. 3310(a).
Amended by R.2004 d.468, effective December 20, 2004.
See: 36 N.J.R. 1858(b), 36 N.J.R. 5711(a).
In (b), added a new 4i and recodified existing i through ii as ii through iii.
Amended by R.2005 d.35, effective January 18, 2005. |
- |
pdf_text |
| 11 |
11
except 1102
(A117.1), 1110.2, 1110.3, and
(A117.1), |
- |
pdf_text |
| 11 |
11. Manufacturers' data sheets indicating model numbers and listing infor
for equipment, devices and materials. |
- |
pdf_text |
| 11 |
11
Energy
Efficiency
N1101.1-N1101.4
As applicable
As applicable
N1101.7-N1101.12
Building
Building
N1101.13-
N1101.14
Building
Building
N1102 (except
Building
Building
N1102.5.4-
N1102.5.5
and related |
- |
pdf_text |
| 11 |
11
C
h.
Vents and Venting
Plumbi
ng
Plumbing |
- |
pdf_text |
| 11 (cont. 2) |
all be deleted, along with the seco
third sentences.
iv. In Section 13.8, Sizing for Continuous or Intermittent Flows, "Section A-3 and
A-1 in Appendix A" shall be deleted and the following shall be inserted: "5 IN/HR
GPM/SF and 6 IN/HR = 0.062 GPM/SF." |
- |
pdf_text |
| 1101.1-1101.1.2 |
1101.1-1101.1.2
Fire/Plumbing
Plumbing |
- |
pdf_text |
| 1101.1-1101.1.2 |
1101.1-1101.1.2
Fire/Plumbing
Plumbing |
- |
pdf_text |
| 1101.1-1102.6 |
1101.1-1102.6
Building
Building |
- |
pdf_text |
| 1101.2 |
1101.2
Plumbing
Plumbing |
- |
pdf_text |
| 1101.2 |
1101.2
Plumbing
Plumbing |
- |
pdf_text |
| 1101.3 |
1101.3
Building
Building |
- |
pdf_text |
| 1101.3 |
1101.3
Building
Building |
- |
pdf_text |
| 1101.4-1101.5 |
1101.4-1101.5
Plumbing
Plumbing |
- |
pdf_text |
| 1101.4-1101.5 |
1101.4-1101.5
Plumbing
Plumbing |
- |
pdf_text |
| 1101.7 |
1101.7
Plumbing
Plumbing |
- |
pdf_text |
| 1101.7 |
1101.7
Plumbing
Plumbing |
- |
pdf_text |
| 1101.8 |
1101.8
Fire
Fire |
- |
pdf_text |
| 1101.8 |
1101.8
Fire
Fire |
- |
pdf_text |
| 1101.9 |
1101.9
Plumbing
Plumbing |
- |
pdf_text |
| 1101.9 |
1101.9
Plumbing
Plumbing |
- |
pdf_text |
| 1102 |
1102
See below for
See below for A117.1
A117.1
A117.1 301.1-308.3.2
Building
Building
A117.1 309
As applicable
As applicable
A117.1 401.1-406.14
Building
Building
A117.1 407-410
Elevator
Elevator
A117.1 501.1-506.1
Building
Building
A117.1 602.1-602.2
Building/Plumb
ing
Plumbing
A117.1 602.2.1
Building/Plumb
ing
Building
A117.1 602.2.3-602.4
Building/Plumb
ing
Plumbing
A117.1 602.4.1
Building/Plumb
ing
Building
A117.1 602.4.2
Building/Plumb
ing
Plumbing
A117.1 603.1-603.6
Building
Building
A117.1 604.1
Building/Plumb
Building |
- |
pdf_text |
| 1102-1103 |
1102-1103
Plumbing
Plumbing |
- |
pdf_text |
| 1102-1103 |
1102-1103
Plumbing
Plumbing |
- |
pdf_text |
| 1102.10 |
1102.10
Building
Building |
- |
pdf_text |
| 1102.11 |
1102.11
As applicable
As applicable |
- |
pdf_text |
| 1102.12-1103.6 |
1102.12-1103.6
Building
Building |
- |
pdf_text |
| 1102.7-1102.9 |
1102.7-1102.9
As applicable
As applicable |
- |
pdf_text |
| 1103.10 |
1103.10
Building
Building |
- |
pdf_text |
| 1103.11-1103.11.2.1 |
1103.11-1103.11.2.1
A117.1 1103.11.2.2
As applicable
As applicable
A117.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 1103.11-1103.11.2.1 |
1103.11-1103.11.2.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 1103.11.2.2 |
1103.11.2.2
As applicable
As applicable |
- |
pdf_text |
| 1103.11.2.3-1103.11.2.4 |
1103.11.2.3-1103.11.2.4
A117.1 1103.11.2.4.1
Building/Plumb
ing
Plumbing
A117.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 1103.11.2.3-1103.11.2.4 |
1103.11.2.3-1103.11.2.4
Building/Plumb
ing
Building |
- |
pdf_text |
| 1103.11.2.4.1 |
1103.11.2.4.1
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1103.11.2.4.2-1103.11.2.4.4 |
1103.11.2.4.2-1103.11.2.4.4
Building/Plumb
ing
Building |
- |
pdf_text |
| 1103.11.2.4.2-1103.11.2.4.4 |
1103.11.2.4.2-1103.11.2.4.4
A117.1
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1103.11.2.4.5-1103.11.2.4.6 |
1103.11.2.4.5-1103.11.2.4.6
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1103.11.2.4.5-1103.11.2.4.6 |
1103.11.2.4.5-1103.11.2.4.6
A117.1
As applicable
As applicable |
- |
pdf_text |
| 1103.11.2.5.1-1103.11.2.5.2 |
1103.11.2.5.1-1103.11.2.5.2
As applicable
As applicable |
- |
pdf_text |
| 1103.11.2.5.1-1103.11.2.5.2 |
1103.11.2.5.1-1103.11.2.5.2
A117.1
Building
Building |
- |
pdf_text |
| 1103.12-1103.12.3.3 |
1103.12-1103.12.3.3
Building
Building |
- |
pdf_text |
| 1103.12-1103.12.3.3 |
1103.12-1103.12.3.3
A117.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 1103.12.4-1103.12.4.2 |
1103.12.4-1103.12.4.2
Building/Plumb
ing
Building |
- |
pdf_text |
| 1103.12.4-1103.12.4.2 |
1103.12.4-1103.12.4.2
A117.1
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1103.12.4.3-1103.12.4.4 |
1103.12.4.3-1103.12.4.4
A117.1
Building
Building |
- |
pdf_text |
| 1103.12.4.3-1103.12.4.4 |
1103.12.4.3-1103.12.4.4
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1103.12.5.1 |
1103.12.5.1, entitled "Operable parts"; section 1103.12.5.3, entitled "Dishwash |
- |
pdf_text |
| 1103.12.5.2-1103.14 |
1103.12.5.2-1103.14
Building
Building |
- |
pdf_text |
| 1103.2.3.1 |
1103.2.3.1 Townhouses. Townhouses are not required to comply with this
except townhouses for which credit is sought for low- and moderate-incom
housing in accordance with N.J.S.A. 52:27D-301 et seq.; |
- |
pdf_text |
| 1103.2.3.1 |
1103.2.3.1 Townhouses. Townhouses are not required to comply with this
except townhouses for which credit is sought for low and moderate income
through the Council on Affordable Housing (COAH); |
- |
pdf_text |
| 1103.2.3.1.1 |
1103.2.3.1.1 For the purposes of applying this exemption, a townhouse
a single dwelling unit with two or more stories of dwelling space, exclu
basement or attic, where each dwelling unit extends from foundation to |
- |
pdf_text |
| 1103.2.3.1.1 |
1103.2.3.1.1 For the purposes of applying this exemption, a townhouse
a single dwelling unit with two or more stories of dwelling space, exclu
basement or attic, where each dwelling unit extends from foundation to |
- |
pdf_text |
| 1103.2.3.2 |
1103.2.3.2. Buildings of Group R-2, R-3, R-4, or R-5 with one, two, or thre
dwelling units in a single structure; |
- |
pdf_text |
| 1103.2.3.2 |
1103.2.3.2 Buildings of Group R-2, R-3, R-4, or R-5 with one, two, or thre
dwelling units in a single structure; |
- |
pdf_text |
| 1103.2.3.2.1 |
1103.2.3.2.1 For the purposes of determining the number of dwelling u
single structure, firewalls or partywalls shall not constitute separate bui |
- |
pdf_text |
| 1103.2.3.2.1 |
1103.2.3.2.1 For the purposes of determining the number of dwelling u
single structure, firewalls or partywalls shall not constitute separate bui |
- |
pdf_text |
| 1103.2.3.2.2 |
1103.2.3.2.2 Exception: Townhouses or multistory dwelling units for
credit is sought for low or moderate income housing in accordance wit
N.J.S.A. 52:27D-301 et seq., and that are attached to at least one other
unit shall comply with this chapter."
v. In Section 1103.2.5, Construction sites, the following exception shall be inserte
"Exception: Construction site trailers used as sales offices shall be accessible."
vi. Section 1104.1, Site arrival points, in the exception, "Other than in buildings o
facilities containing or serving Type B units," shall be deleted and "an" shall be ca
vii. Section 1104.4, Multistory buildings and facilities, shall be deleted and the fol
shall be inserted:
"1104.4 Multilevel nonresidential buildings and multilevel buildings of Group
An accessible route of travel shall be provided in multilevel nonresidential buil
and multilevel buildings of Group R-1 in accordance with Sections 1104.4.1 - |
- |
pdf_text |
| 1103.2.3.2.2 |
1103.2.3.2.2 Exception: Townhouses or multistory dwelling units for w
credit is sought for low or moderate income housing through the Counc
Affordable Housing (COAH) and that are attached to at least one other
unit shall comply with this chapter."
vi. In Section 1103.2.5, Construction sites, the following exception shall be insert
"Exception: Construction site trailers used as sales offices shall be accessible."
vii. Section 1104.1, Site arrival points, in the exception, "Other than in buildings o
facilities containing or serving Type B units," shall be deleted and "an" shall be ca
viii. Section 1104.4, Multistory buildings and facilities, shall be deleted and the fo
shall be inserted:
"1104.4 Multilevel nonresidential buildings and multilevel buildings of Group
accessible route of travel shall be provided in multilevel nonresidential buildin
multilevel buildings of Group R-1 in accordance with Sections 1104.4.1 - 1104 |
- |
pdf_text |
| 1103.9 |
1103.9
As applicable
As applicable |
- |
pdf_text |
| 1104.1 |
1104.1
Plumbing
Plumbing |
- |
pdf_text |
| 1104.1 |
1104.1
Plumbing
Plumbing |
- |
pdf_text |
| 1104.2-1104.4 |
1104.2-1104.4
Building/Fire
Fire |
- |
pdf_text |
| 1104.2-1104.4 |
1104.2-1104.4
Building/Fire
Fire |
- |
pdf_text |
| 1104.4.1 |
1104.4.1 Small Buildings. Small buildings, defined as those with a total gr
enclosed floor area of less than 10,000 square feet, shall be required to hav
one accessible entrance on the ground (or first) floor and accessible interior
building features on all floors. Except as provided in Sections 1104.4.1.1- |
- |
pdf_text |
| 1104.4.1 |
1104.4.1 Small Buildings. Small buildings, defined as those with a total gr
enclosed floor area of less than 10,000 square feet, shall be required to hav
one accessible entrance on the ground (or first) floor and accessible interior
building features on all floors. Except as provided in Sections 1104.4.1.1- |
- |
pdf_text |
| 1104.4.1.1 |
1104.4.1.1 Regardless of the square footage of the buildings or floors,
of two or more stories that are owned and occupied by public entities s
provide a vertical accessible route between floors. |
- |
pdf_text |
| 1104.4.1.1 |
1104.4.1.1 Regardless of the square footage of the buildings or floors,
buildings of two or more stories that are owned and occupied by public
shall provide a vertical accessible route between floors. |
- |
pdf_text |
| 1104.4.1.2 |
1104.4.1.2 Regardless of the square footage of the buildings or floors,
of two or more stories that house public transit stations or airport passe
terminals shall provide a vertical accessible route between floors. |
- |
pdf_text |
| 1104.4.1.2 |
1104.4.1.2 Regardless of the square footage of the buildings or floors,
buildings of two or more stories that house public transit stations or air
passenger terminals shall provide a vertical accessible route between fl |
- |
pdf_text |
| 1104.4.1.3 |
1104.4.1.3 Regardless of the square footage of the buildings or floors,
of two or more stories that house the professional offices of health care
providers shall provide a vertical accessible route between floors. |
- |
pdf_text |
| 1104.4.1.3 |
1104.4.1.3 Regardless of the square footage of the buildings or floors,
buildings of two or more stories that house the professional offices of h
care providers shall provide a vertical accessible route between floors. |
- |
pdf_text |
| 1104.4.1.4 |
1104.4.1.4 Regardless of the square footage of the buildings or floors,
buildings of two or more stories that house shopping centers or shoppin
shall provide a vertical accessible route between floors. |
- |
pdf_text |
| 1104.4.1.4 |
1104.4.1.4 Regardless of the square footage of the buildings or floors,
of two or more stories that house shopping centers or shopping malls sh
provide a vertical accessible route between floors. |
- |
pdf_text |
| 1104.4.1.4.1 |
1104.4.1.4.1 For the purposes of applying this requirement, a shopp
center or shopping mall shall mean a building or a series of buildin
common site, under common ownership or control, or developed as
project or as a series of related projects housing five or more sales o
establishments. |
- |
pdf_text |
| 1104.4.1.4.1 |
1104.4.1.4.1 For the purposes of applying this requirement, a shop
center or shopping mall shall mean a building or a series of buildin
common site, under common ownership or control, or developed as
project or as a series of related projects housing five or more sales o
establishments. |
- |
pdf_text |
| 1104.4.1.5 |
1104.4.1.5, small buildings that are not more than two stories shall not be r |
- |
pdf_text |
| 1104.4.2 |
1104.4.2 Large buildings. Large buildings, defined as those with a total gro
enclosed floor area of 10,000 square feet or more, shall provide the accessi
building features required of small buildings in Section 1104.4.1. In additio
buildings shall be required to have an elevator(s) to provide a vertical acces
route between floors; however, in such buildings, floors that are less than 3 |
- |
pdf_text |
| 1104.4.2 |
1104.4.2 Large buildings. Large buildings, defined as those with a total gr
enclosed floor area of 10,000 square feet or more, shall provide the accessi
building features required of small buildings in Section 1104.4.1. In additio
buildings shall be required to have an elevator(s) to provide a vertical acces
route between floors, including occupiable roofs; however, in such buildin |
- |
pdf_text |
| 1104.4.2.1 |
1104.4.2.1 Where facilities for employees, including rest rooms, lunch
and lockers, and public facilities, including rest rooms and drinking fou
are provided on a floor or mezzanine that is not required to be served b
elevator and where no vertical accessible route is provided, the facilitie
provided on the floor or mezzanine must also be provided on the access
level. |
- |
pdf_text |
| 1104.4.2.1 |
1104.4.2.1 Where facilities for employees, including rest rooms, lunch
and lockers, and public facilities, including rest rooms and drinking fou
are provided on a floor or mezzanine that is not required to be served b
elevator and where no vertical accessible route is provided, the facilitie
provided on the floor or mezzanine must also be provided on the access
level. |
- |
pdf_text |
| 1104.4.3 |
1104.4.3 For the purposes of applying these provisions, buildings separated
firewalls with penetrations intended for human passage shall not constitute
buildings. |
- |
pdf_text |
| 1104.4.3 |
1104.4.3 For the purposes of applying these provisions, buildings separate
firewalls with penetrations intended for human passage shall not constitute
buildings. |
- |
pdf_text |
| 1104.4.4 |
1104.4.4 The following provisions shall apply to a nonresidential building
to be accessible, whether a large building or a small building. |
- |
pdf_text |
| 1104.4.4 |
1104.4.4 The following provisions shall apply to a nonresidential building
to be accessible, whether a large building or a small building. |
- |
pdf_text |
| 1104.4.4.1 |
1104.4.4.1 An accessible route available to the general public shall not
through kitchens, storage rooms, or similar spaces. |
- |
pdf_text |
| 1104.4.4.1 |
1104.4.4.1 An accessible route available to the general public shall not
through kitchens, storage rooms, or similar spaces. |
- |
pdf_text |
| 1104.4.4.2 |
1104.4.4.2 In buildings, facilities, or portions thereof that primarily ser
children, accessible facilities that comply with the provisions of this su
for use by adults shall be provided." |
- |
pdf_text |
| 1104.4.4.2 |
1104.4.4.2 In buildings, facilities, or portions thereof that primarily ser
children, accessible facilities that comply with the provisions of this su
for use by adults shall be provided." |
- |
pdf_text |
| 1104.4.5 |
1104.4.5 Limited Use Limited Access Elevators--the use of a Limited Use
Access Elevator shall be permitted in accordance with the provisions of 11
ix. In Section 1104.5, Location, exception 1 shall be deleted. In addition, in excep
"or Type B unit" shall be deleted and "or" shall be inserted between "Accessible u
"Type A unit."
x. In Section 1105.1, Public entrances, after "... at least sixty percent of all public
entrances shall be accessible." insert "The primary entrance(s) used by the general
shall be accessible." |
- |
pdf_text |
| 1104.4.5 |
1104.4.5 Limited Use Limited Access Elevators--the use of a Limited Use
Access Elevator shall be permitted in accordance with the provisions of 11
viii. In Section 1104.5, Location, exception 1 shall be deleted. In addition, in exce
"or Type B unit" shall be deleted and "or" shall be inserted between "Accessible u
"Type A unit."
ix. At Section 1105.1, Public entrances, insert the following new sentence "The pr
entrance(s) used by the general public shall be accessible." |
- |
pdf_text |
| 1105.1-1105.2 |
1105.1-1105.2
Building
Building |
- |
pdf_text |
| 1105.1-1105.2 |
1105.1-1105.2
Building
Building |
- |
pdf_text |
| 1105.3-1105.5 |
1105.3-1105.5
Fire
Fire |
- |
pdf_text |
| 1105.3-1105.5 |
1105.3-1105.5
Fire
Fire |
- |
pdf_text |
| 1105.6 |
1105.6
Building
Building |
- |
pdf_text |
| 1105.6 |
1105.6
Building
Building |
- |
pdf_text |
| 1105.7 |
1105.7
Plumbing
Plumbing |
- |
pdf_text |
| 1105.7 |
1105.7
Plumbing
Plumbing |
- |
pdf_text |
| 1105.8-1105.9 |
1105.8-1105.9
Building/Fire
Building |
- |
pdf_text |
| 1105.8-1105.9 |
1105.8-1105.9
Building/Fire
Building |
- |
pdf_text |
| 1106 |
1106
Fire
Fire |
- |
pdf_text |
| 1106 |
1106
Fire
Fire |
- |
pdf_text |
| 1106 |
1106
Building
Building
Ch. |
- |
pdf_text |
| 1106 |
1106
Building
Building |
- |
pdf_text |
| 1106.10.1 |
1106.10.1, Mounting height. The bottom of the lowest sign shall be mount
approximately 60 inches above the parking lot or sidewalk surface when th
parallel to the sidewalk and approximately 72 inches above the parking lot
sidewalk when the sign is perpendicular to the sidewalk. |
- |
pdf_text |
| 1106.10.1 |
1106.10.1, Mounting height. The bottom of the lowest sign shall be
approximately 60 inches above the parking lot or sidewalk surface when th
parallel to the sidewalk and approximately 72 inches above the parking lot or
when the sign is perpendicular to the sidewalk. |
- |
pdf_text |
| 1106.10.2 |
1106.10.2, Location. The penalty sign shall be centered and mounted at th
each parking space."
xiv. At Section 1107.2, Electrical vehicle charging stations, "N.J.A.C. 5:23-2.36 a
be inserted before "Sections." In addition, Exception 1 shall be deleted.
xv. In Section 1108.2, Design, "and Type B units" shall be deleted from the first s
and "and" shall be inserted between "Accessible units" and "Type A units." Additi
the last sentence shall be deleted.
xvi. In Section 1108.3, Accessible spaces, "or Type B units" shall be deleted from
sentence and "or" shall be inserted between "Accessible units" and "Type A units."
"dining areas," the second sentence, "laundry areas, mailboxes and meeting rooms
inserted. The text of Exception #1 shall be deleted and the following shall be insert
place: "Mailboxes shall be mounted at minimum height of 28 inches and a maxim
inches where a parallel approach is provided." Finally, Exception #3 shall be delet
entirety.
xvii. At Section 1108.4, Accessible route, "and Type B units" shall be deleted fro
first sentence and "and" shall be inserted between "Accessible units" and "Type A
Exception 6 is amended to delete "or Type B units" from the second line, to delete
words "and Type B units" on the second line, and to delete the words "and Type B
on the third line. Exception 7 is deleted.
xviii. In Section 1108.5, Group I, "and Type B units" shall be deleted.
xxiv. In Section 1108.5.1, Group I-1, "and Type B units" shall be deleted. A |
- |
pdf_text |
| 1106.10.2 |
1106.10.2, Location. The penalty sign shall be centered and mounted at the
each parking space." |
- |
pdf_text |
| 1106.10.2 (cont. 2) |
dditio
"1108.5.1.3" shall be deleted and "1108.5.1.2" shall be inserted.
xxv. New Section 1108.5.4A shall be inserted between Sections 1108.5.4 and 110
and shall contain the following: |
- |
pdf_text |
| 1107-1111 |
1107-1111
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 1107-1111 |
1107-1111
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 1108.5.2.2 |
1108.5.2.2" shall be deleted.
xxiii. Section 1108.5.2.2, Type B Units, shall be deleted.
xxiv. In Section 1108.5.3, Group I-2 hospitals, "and Type B units" and "and 1108.
shall be deleted.
xxv. Section 1108.5.3.2, Type B Units, shall be deleted in its entirety. |
- |
pdf_text |
| 1108.5.4 |
1108.5.4A.3 In dwelling units in an assisted living facility that are designa
Group R-2 for the purposes of accessibility, the following may be adaptabl |
- |
pdf_text |
| 1108.5.4 |
1108.5.4A.1 Dwelling units that are available for occupancy only for 30 or
consecutive days shall be required to comply with Section 1103 of ICC A1 |
- |
pdf_text |
| 1108.5.4 |
1108.5.4A Assisted living facilities. Assisted living facilities that are licensed
Department of Health are Group I-2 for compliance with the building subcode, |
- |
pdf_text |
| 1108.5.4 |
1108.5.4A.2 Where an assisted living facility includes dwelling units or ro
are available for occupancy for fewer than 30 consecutive days, 50 percent
dwelling units or rooms shall be accessible in compliance with Section 110
A117.1 and shall include one full bathroom that complies with Section 110
A117.1 and, where a kitchen is provided, it shall comply with Section 1102
A117.1. |
- |
pdf_text |
| 1108.5.4 |
1108.5.4A.3.1 The threshold for an accessible transfer shower may be
adaptable as long as the shower threshold can be adapted with minimal
and effort to be accessible; and |
- |
pdf_text |
| 1108.5.4 |
1108.5.4A.3.2 A transfer-type shower of 36 inches by 48 inches that in
an accessible seat may be provided in individual dwelling units. The thr
of this shower shall not exceed four inches.
xxvi. In Section 1108.6, Group R, "and Type B units" shall be deleted from the fir
sentence and "and" shall be inserted between "Accessible units" and "Type A units
xxvii. In Section 1108.6.1, Group R-1, "and Type B units" and "and 1109.6.1.2" s
deleted.
xxviii. Section 1108.6.1.2, Type B units, shall be deleted in its entirety.
xxix. In Section 1108.6.2, Group R-2, "and Type B units" shall be deleted and "an
be inserted between "Accessible units" and "Type A units." |
- |
pdf_text |
| 1108.5.5 |
1108.5.5 Assisted living facilities. Assisted living facilities that are licensed by
Department of Health are Group I-2 for compliance with the building subcode,
protection subcode, and the other subcodes of the Uniform Construction Code
be Group R-2 for the purposes of accessibility. |
- |
pdf_text |
| 1108.5.5.1 |
1108.5.5.1 Dwelling units that are available for occupancy only for 30 or m
consecutive days shall be required to comply with Section 1103 of ICC A1 |
- |
pdf_text |
| 1108.5.5.2 |
1108.5.5.2 Where an assisted living facility includes dwelling units or roo
are available for occupancy for fewer than 30 consecutive days, 50 percent
dwelling units or rooms shall be accessible in compliance with Section 110
A117.1 and shall include one full bathroom that complies with Section 110
A117.1 and, where a kitchen is provided, it shall comply with Section 1102
A117.1. |
- |
pdf_text |
| 1108.5.5.3 |
1108.5.5.3 In dwelling units in an assisted living facility that are designate
R-2 for the purposes of accessibility, the following may be adaptable: |
- |
pdf_text |
| 1108.5.5.3.1 |
1108.5.5.3.1 The threshold for an accessible transfer shower may be ad
as long as the shower threshold can be adapted with minimal expense a
to be accessible; and |
- |
pdf_text |
| 1108.5.5.3.2 |
1108.5.5.3.2 A transfer-type shower of 36 inches by 48 inches that incl
accessible seat may be provided in individual dwelling units. The thres
this shower shall not exceed four inches.
xxvii. In Section 1108.6, Group R, "and Type B units" shall be deleted from the fi
sentence and "and" shall be inserted between "Accessible units" and "Type A units
xxviii. In Section 1108.6.1, Group R-1, "and Type B units" and "and 1109.6.1.2"
deleted. |
- |
pdf_text |
| 1108.6.2.2.2 |
1108.6.2.2.2" shall be deleted, and "Live/Work Units" shall be added before "Apar
in the third line.
xxxiii. Section 1108.6.2.2.1, Type A units, shall be deleted in its entirety and the f
shall be inserted:
"1108.6.2.2.1 Type A units. In Group R-2 live/work units, apartment houses,
monasteries and convents containing four or more dwelling units or sleeping u
ground floor dwelling units in a building without elevator service and all dwell
in an elevator serviced building shall be Type A units. For the purpose of appl
requirement, the ground floor shall mean, in a building containing dwelling uni
first floor with a dwelling unit or portion of a dwelling unit, regardless of whet
floor is at grade. A building may have more than one ground floor.
Exception: The number of Type A units is permitted to be reduced in accord |
- |
pdf_text |
| 1108.6.2.2.2 |
1108.6.2.2.2" shall be deleted, and "Live/Work Units" shall be added before "Apar
in the first line.
xxxii. Section 1108.6.2.2.1, Type A units, shall be deleted in its entirety and the f
shall be inserted:
"1108.6.2.2.1 Type A units. In Group R-2 live/work units, apartment houses,
monasteries and convents containing four or more dwelling units or sleeping u
ground floor dwelling units in a building without elevator service and all dwell
in an elevator serviced building shall be Type A units. For the purpose of appl
requirement, the ground floor shall mean, in a building containing dwelling uni
first floor with a dwelling unit or portion of a dwelling unit, regardless of whet
floor is at grade. A building may have more than one ground floor.
Exception: The number of Type A units is permitted to be reduced in accord |
- |
pdf_text |
| 1108.7 |
1108.7.
xxxvii. In Section 1108.6.3, Group R-3, "Type B units" shall be deleted in the sect
the exception and "Type A units" inserted in its place in both locations.
xxxviii. In Section 1108.6.4, Group R-4, "Type B units" shall be deleted and "Typ
units" inserted in its place.
xxxix. Section 1108.6.4.2, Type B units, shall be retitled "Type A units". Addition
"Type B units" shall be deleted in the section and the exception and "Type A units
inserted in its place in both locations.
xl. Insert new section 1108.6.5 as follows:
"1108.6.5 COAH Units. The exemption for townhouses and multistory units
notwithstanding, multistory or multifloor townhouses for which credit is sough
or moderate income housing through the Council on Affordable Housing (CO
have the following features, which shall comply with the standards for Type A
dwelling units per ICC A117.1: |
- |
pdf_text |
| 1108.7 |
1108.7.
xxxiii. Section 1108.6.2.2.2, Type B units, shall be deleted in its entirety.
xxxiv. In Section 1108.6.2.3, Group R-2 other than live/work units, apartment hou
monasteries and convents, "Type B units" shall be deleted and "Type A units" inse
its place.
xxxv. Section 1108.6.2.3.2, Type B units, shall be deleted in its entirety and the fo
shall be inserted:
"1108.6.2.3.2 Type A units. In Group R-2 occupancies other than live/work u
apartment houses, monasteries and convents containing four or more dwelling |
- |
pdf_text |
| 1108.7 |
1108.7.
xxxiv. Section 1108.6.2.2.2, Type B units, shall be deleted in its entirety.
xxxv. In Section 1108.6.2.3, Group R-2 other than live/work units, apartment hou
monasteries and convents, "Type B units" shall be deleted and "Type A units" inse
its place. |
- |
pdf_text |
| 1108.7 |
1108.7.
xxxvi. At Section 1108.6.3, Group R-3, "Type B units" shall be deleted in the first
"Type A units" inserted in its place.
xxxvii. Section 1108.6.3.2, Type B units, shall be retitled "Type A units". Additio
"Type B units" shall be deleted in the section and the exception and "Type A units
inserted in its place in both locations.
xxxviii. In Section 1108.6.4, Group R-4, "Type B units" shall be deleted and "Typ
units" inserted in its place.
xxxix. Section 1108.6.4.2, Type B units, shall be retitled "Type A units". Addition
"Type B units" shall be deleted in the section and the exception and "Type A units
inserted in its place in both locations.
xl. Insert new Section 1108.6.5 as follows:
"1108.6.5 Affordable housing units receiving credits pursuant to N.J.S.A. 52:
et seq. The exemption for townhouses and multistory units notwithstanding, m
or multifloor townhouses for which credit is sought for low- or moderate-inco
housing in accordance with N.J.S.A. 52:27D-301 et seq., shall have the followi
features, which shall comply with the standards for Type A dwelling units per
A117.1: |
- |
pdf_text |
| 1110.18 |
1110.18
Controls
Controls shall be the
shall be the
responsibility of the person
responsibility
responsible for the control
of the person
in the general sections of
responsible for
the code
the control in
the general
sections of the
code
C
h.
Interior Environment
Building
Building |
- |
pdf_text |
| 1110.2-1110.2.1.6 |
1110.2-1110.2.1.6
Building/Plumb
ing
Building |
- |
pdf_text |
| 1110.2.2.1 |
1110.2.2.1
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1110.2.2.2 |
1110.2.2.2
Building/Plumb
ing
Building |
- |
pdf_text |
| 1110.2.2.3 |
1110.2.2.3
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1110.2.2.4 |
1110.2.2.4
Building/Plumb
ing
Building |
- |
pdf_text |
| 1110.2.2.5 |
1110.2.2.5
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1110.2.2.6 |
1110.2.2.6
Building/Plumb
ing
Building |
- |
pdf_text |
| 1110.2.3.1 |
1110.2.3.1
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1110.2.3.2-1110.2.3.4 |
1110.2.3.2-1110.2.3.4
Building/Plumb
ing
Building |
- |
pdf_text |
| 1110.2.3.5-1110.2.3.6 |
1110.2.3.5-1110.2.3.6
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1110.2.3.7-1110.2.3.8 |
1110.2.3.7-1110.2.3.8
Building/Plumb
ing
Building |
- |
pdf_text |
| 1110.2.3.9 |
1110.2.3.9
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 1110.2.4-1110.3 |
1110.2.4-1110.3
Building/Plumb
ing
Building |
- |
pdf_text |
| 1111.4.12.2 |
1111.4.12.2, Miniature golf course configuration, and 1111.4.12.3, Accessible rout
be deleted in their entirety.
lv. In Section 1111.4.14, Swimming pools, wading pools, cold baths, hot tubs, an
Exception 3 shall be deleted in its entirety.
lvi. In Section 1112.1, Signs, the exception to Item #1 shall be deleted. Additional
last line of the exception to Item #2, "an assigned" shall be inserted following
"identification of" and "spaces" shall be deleted and "space" shall be inserted.
lvii. In Section 1112.4, Other signs, Item #7 shall be deleted in its entirety.
lviii. Insert new Section 1113, Variations, as follows:
"Section 1113. Variations |
- |
pdf_text |
| 1111.4.12.2 |
1111.4.12.2, Miniature golf course configuration, and 1111.4.12.3, Accessible rout
be deleted in their entirety.
lvi. In Section 1111.4.14, Swimming pools, wading pools, cold baths, hot tubs, an
Exception 3 shall be deleted in its entirety.
lvii. In Section 1112.1, Signs, the exception to Item #1 shall be deleted. Additiona
the last line of the exception to Item #2, "an assigned" shall be inserted following
"identification of" and "spaces" shall be deleted and "space" shall be inserted. |
- |
pdf_text |
| 1113.1 |
1113.1 General. Where it can be demonstrated that one or more of the prov
this subchapter are technically infeasible, variations or exceptions to those
provisions may be granted if: |
- |
pdf_text |
| 1113.1 |
1113.1 General. Where it can be demonstrated that one or more of the provisio
this subchapter are technically infeasible, variations or exceptions to those spe
provisions may be granted if: |
- |
pdf_text |
| 1113.2 |
1113.2 Prohibited. In no case shall a complete waiver of these requirements be |
- |
pdf_text |
| 1113.2 |
1113.2 Prohibited. In no case shall a complete waiver of these requirement
granted. |
- |
pdf_text |
| 1113.3 |
1113.3 Procedure. Procedures for granting variations and exceptions shall be i
accordance with N.J.A.C. 5:23-2.9 through 2.13." |
- |
pdf_text |
| 1113.3 |
1113.3 Procedure. Procedures for granting variations and exceptions shall
accordance with N.J.A.C. 5:23-2.9 through 2.13." |
- |
pdf_text |
| 12 |
12. Under the heading of "Air Freezing Index," insert "1500 or less"; |
- |
pdf_text |
| 12 |
12. Details of ceiling height and construction. |
- |
pdf_text |
| 12 |
12. Delete section 608.8, entitled "Water Temperature," in its entirety. |
- |
pdf_text |
| 12 |
12
Hydronic Piping
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 12 |
12. Chapter 13, General Mechanical System Requirements, shall be amended as follo
i. In Section M1305.1.2.1, Electrical requirements, "Chapter 39" shall be deleted a
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
ii. In Section M1305.1.3.3, Electrical requirements, "Chapter 39" shall be deleted
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
iii. Section M1307.4, Hydrogen generating and refueling operations, shall be delet
entirety and the following shall be inserted:
M1307.4 Hydrogen generating and refueling operations. The installation of hy
fuel cell systems shall be installed in accordance with the applicable requireme
the International Fire Code, the International Building Code, the International
Mechanical Code and the International Fuel Gas Code.
iv. In Section M1307.5, Electrical appliances, "and 34 through 43" shall be delete
"and the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted at the end of the
sentence.
v. Section M1307.6, Plumbing Connections, "Chapters 29 and 30" shall be delete
"the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted in its place.
vi. Add new Section M1307.8 as follows:
M1307.8 Safety devices and controls. Oil burners, other than oil stoves with i
tanks, shall be provided with means for manually stopping the flow of oil to th
Such device or devices shall be placed in a readily accessible location a minim
feet from the burner. For electrically driven equipment, an identified sw |
- |
pdf_text |
| 12 |
12
Energy Cost Budget
As applicable
As applicable
Method
IEC
C-C
App
endi
ces
CB
Solar-Ready
As applicable
As applicable
Zone--Commercial
CC
Zero Energy
As applicable
As applicable
Commercial Building
Provisions
CD
The 2030 Glide
As applicable
As applicable
Path
CE
Required HVAC
As applicable
As applicable
Total System
Performance Ratio
CF
Energy Credits
As applicable
As applicable
CG
Electric Vehicle
As applicable
As applicable |
- |
pdf_text |
| 12 |
12. Chapter 13, Energy Efficiency, shall be deleted in its entirety. |
- |
pdf_text |
| 12 |
12. Commercial farm buildings exempted under (d)11i above shall meet the followin
requirements in lieu of those requirements specified in the subsections of Chapter 10,
Egress, of the building subcode: |
- |
pdf_text |
| 12 |
12
C
h.
Storm Water Drainage
Plumbi
ng
Plumbing |
- |
pdf_text |
| 12 |
12
Interior Environment
Building
Building
Ch. |
- |
pdf_text |
| 12 |
12
C
h.
Storm Water Drainage
Plumbi
ng
Plumbing |
- |
pdf_text |
| 12 |
12. Appendix A, "Chimney Connector Pass-Throughs," is informative and is not part
code. |
- |
pdf_text |
| 12 |
12. Stadiums, arenas and theaters with an occupant load of 5,000 or greater.
(b) The Department of Community Affairs shall be the sole plan review agency for elevat
escalators, and moving walks in structures of Groups other than R-2, R-3, R-4, or R-5 in
elevator devices are wholly within dwelling units and not accessible to the general public,
buildings and structures other than those that: |
- |
pdf_text |
| 12 |
12. Chapter 13, Energy Efficiency, shall be deleted in its entirety. |
- |
pdf_text |
| 12 |
12. Chapter 13, General Mechanical System Requirements, shall be amended as follo
i. In Section M1305.1.2.1, Electrical requirements, "Chapter 39" shall be deleted a
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
ii. In Section M1305.1.3.3, Electrical requirements, "Chapter 39" shall be deleted
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
iii. Section M1307.4, Hydrogen generating and refueling operations, shall be delet
entirety and the following shall be inserted:
M1307.4 Hydrogen generating and refueling operations. The installation of hy
fuel cell systems shall be installed in accordance with the applicable requireme
the International Fire Code, the International Building Code, the International
Mechanical Code and the International Fuel Gas Code.
iv. In Section M1307.5, Electrical appliances, "and 34 through 43" shall be delete
"and the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted at the end of the
sentence.
v. Section M1307.6, Plumbing Connections, "Chapters 29 and 30" shall be delete
"the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted in its place.
vi. Add new Section M1307.8 as follows: |
- |
pdf_text |
| 12 |
12. Chapter 15 of the plumbing subcode, entitled "Tests and Maintenance" is amende
follows:
i. Add new Section 15.6.1 as follows: 15.6.1 Combination Domestic/Fire Water S
Systems: Piping for combination domestic/fire water services systems shall be pre
tested to not less than 200 psig and shall maintain that pressure without loss for 2 h
ii. Add new Section 15.6.1.1 as follows: 15.6.1.1 Leakage: The following provisio
apply to buried pipe in all combination domestic/fire water service systems, except
limited sprinkler systems:
(1) The amount of leakage at the joints shall be no greater than 2 qt/hr (1.89 L |
- |
pdf_text |
| 12 |
12. Chapter 15 of the mechanical subcode, entitled "Referenced Standards," shall be a
as follows:
i. Under the heading "ICC," amend the following title:
(1) Delete "IPC--21, International Plumbing Code." |
- |
pdf_text |
| 12 |
12
Hydronic Piping
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 12 |
12
C
h.
Exterior Walls
Building
Building |
- |
pdf_text |
| 12 |
12-month period, may be served by a portable restroom.
History |
- |
pdf_text |
| 12 (cont. 2) |
itch in
burner supply circuit shall be provided at the entrance to the room or area wher
appliance is located or, for equipment located in basements, the switch is requi
located at the top of stairs leading to the basement. An identifiable valve in the
supply line, operable from a location a minimum of 10 feet from the burner, sh
used for other than electrically driven or controlled equipment. |
- |
pdf_text |
| 12.10 |
12.10 WET VENTING |
- |
pdf_text |
| 12.10.1 |
12.10.1 Single Bathroom Groups
a. An individually vented lavatory in a single bathroom group shall be
permitted to serve as a wet vent for the water closet, the bathtub, or sho
stall, the water closet and bathtub/shower if all of the following conditi
met. |
- |
pdf_text |
| 12.10.2 |
12.10.2 Double Bathtubs and Lavatories
Two lavatories and two bathtubs or showers back-to-back may be install
same horizontal branch with a common vent for the lavatories and with
vent for the bathtubs or shower stalls provided the wet vent is 2" in siz
lengths of the tub/shower drains conform to Table 12.8.1. |
- |
pdf_text |
| 12.10.3 |
12.10.3 Multi-Story Bathroom Groups
a. On the lower floors of a stack, the waste pipe from one or two lavat
may be used as a wet vent for one or two bathtubs or showers as provid |
- |
pdf_text |
| 12.10.4 |
12.10.4 Bathtubs and Water Closets
a. An individually vented bathtub in a single bathroom group shall be
to serve as a wet vent for the water closet if all of the following conditi
met: |
- |
pdf_text |
| 12.10.6 |
12.10.6 Floor Drains and Floor Sinks
a. A lavatory or sink shall be permitted to serve as a wet vent for a floo
or floor sink if all of the following conditions are met: |
- |
pdf_text |
| 13 |
13. Appendix A of the mechanical subcode entitled "Chimney Connector Pass-Throu
informative and is not part of the code. |
- |
pdf_text |
| 13 |
13. The interface of fire safety control functions. |
- |
pdf_text |
| 13 |
13
Fuel Oil Piping and
Storage |
- |
pdf_text |
| 13 |
13. Under the heading of "Mean Annual Temp;" insert "see Note j"; |
- |
pdf_text |
| 13 |
13. Chapter 14, Exterior Walls, shall be amended as follows:
i. At Section 1404.12.4, Grounding, "Chapter 27 of this code" shall be deleted an
electrical subcode, N.J.A.C. 5:23-3.16" shall be inserted. |
- |
pdf_text |
| 13 |
13. Site plans signed and sealed by a registered architect or a licensed engineer, pursu
N.J.A.C. 5:23-2.15(f)1ix, shall not be required, provided that a sketch plan of the site i
submitted to the construction official. |
- |
pdf_text |
| 13 |
13
Fuel Oil Piping and
Storage |
- |
pdf_text |
| 13 |
13 listed in Chapter 35."
xv. In Section 904.2, Where permitted, "fire code official" shall be deleted and "fi
protection subcode official" shall be inserted.
xvi. In Section 904.5, Wet-chemical systems, delete the last sentence.
xvii. In Section 904.6, Dry-chemical systems, delete the last sentence.
xviii. In Section 904.7, Foam systems, delete the last sentence.
xix. In Section 904.8, Carbon dioxide systems, delete the last sentence.
xx. In Section 904.9, Halon systems, delete the last sentence.
xxi. In Section 904.10, Clean-agent systems, delete the last sentence.
xxii. In Section 904.11.1.3 Water supply protection, "International Plumbing Cod
be deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
xxiii. At Section 905.2, Installation standard, Sections 915.4, 915.5, and 915.6 of t
BOCA National Building Code shall be inserted as follows: "905.2.1 Piping desig
riser piping, supply piping and the water service piping shall be sized to maintain a
pressure of at least 65 psi (448 kPa) at the topmost outlet of each riser while flowi
minimum quantities of water specified at Sections 905.2.1.1 and 905.2.1.2. The pi
shall be based on the capacity of the automatic water supply system or, where an a |
- |
pdf_text |
| 13 |
13. Chapter 14, Exterior Walls, shall be amended as follows: |
- |
pdf_text |
| 13 |
13. Chapter 16 of the plumbing subcode, entitled "Regulations Governing Individual
Disposal Systems for Homes and Other Establishments Where Public Sewer Systems
Available," shall be deleted and the following shall be inserted:
i. "16.1 General. On-site sewage disposal systems are under the jurisdiction of the
Department of Environmental Protection and the county or local boards of health,
applicable."
ii. "16.1.7 Abandoned Disposal Systems. When an existing building is being dem
and the existing sewage disposal system is abandoned or an existing sewage dispo
system is being abandoned and a connection is being made to the public sewer sys
plumbing subcode official shall ensure that the existing abandoned tank is disconn
from the building, pumped out, and filled with gravel, stones, or soil material. Sew
disposal systems that are abandoned without an associated hookup to a public sew
system are to be inspected by the health department having jurisdiction." |
- |
pdf_text |
| 13 |
13
Mechanical System
Requirements
M1301
Plumbing
Plumbing
M1302
Fire/Plumbing
Plumbing
M1303
Electrical/Plumbing
Plumbing
M1304
Fire/Plumbing
Plumbing
M1305-M1305.1.2
Building
Building
M1305.1.2.1
Electrical
Electrical
M1305.1.3
Plan Review and Field Inspection for access, passageways, and service clearances for appliances shall b
the responsibility of the subcode with plan review and inspection responsibility for the appliance
M1306.1
Fire
Fire
M1306.2-M1306.2.3
Building/Fire
Fire
M1307.1
Fire
Fire
M1307.2
Building
Building
M1307.3-M1307.4.3
Fire
Fire |
- |
pdf_text |
| 13 |
13. Chapter 14, Heating and Cooling Equipment, shall be amended as follows:
i. Section M1401.3, Equipment and appliance sizing, "When provided" shall be in
the beginning of the sentence.
ii. In Section M1405.1, General, "Chapters 34 through 43" shall be deleted and "t
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
iii. In Section M1406.1, General, "Chapters 34 through 43" shall be deleted and "t
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
iv. In Section M1406.2, Clearances, "Chapters 34 through 43" shall be deleted an
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
v. In Section M1407.1, General, "Chapters 34 through 43" shall be deleted and "th
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
vi. In Section M1411.3, Condensate disposal, in the first sentence, "in accordance
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted after "disposal."
vii. Section M1411.3.2, Drain pipe materials and sizes, shall be deleted in its entir
viii. In Section M1413.1, General, "Section P2902" shall be deleted in item #4 an
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 13 |
13. In section 611, entitled "Washing Machines and Clothes Dryers," delete se |
- |
pdf_text |
| 13 |
13 listed in Chapter 35.
xviii. In Section 904.2, Where permitted, "fire code official" shall be deleted and "
protection subcode official" shall be inserted.
xix. In Section 904.5, Wet-chemical systems, delete the last sentence.
xx. In Section 904.6, Dry-chemical systems, delete the last sentence.
xxi. In Section 904.7, Foam systems, delete the last sentence. |
- |
pdf_text |
| 13 |
13
C
h.
Special Requirements for Health Care
Plumbi
ng
Plumbing |
- |
pdf_text |
| 13 |
13. Appendix B, "Recommended Permit Fee Schedule," and Appendix C, "Board of
are deleted in their entirety. |
- |
pdf_text |
| 13 |
13
C
h.
Special Requirements for Health Care
Plumbi
ng
Plumbing |
- |
pdf_text |
| 13 |
13
General
Mechanical
System
Requirements
M1301
Plumbing
Plumbing
M1302
Fire/Plumbing
Plumbing
M1303
Electrical/Plumbing
Plumbing
M1304
Fire/Plumbing
Plumbing
M1305-M1305.1.2
Building
Building
M1305.1.2.1
Electrical
Electrical
M1305.1.3
Plan Review and Field
Inspection for access,
passageways, and service clearances for appliances
shall be the responsibility of the subcode with
plan review and inspection responsibility for the
appliance
M1306.1
Fire
Fire
M1306.2
Building/Fire
Fire
M1307.1
Fire
Fire
M1307.2
Building
Building
M1307.3-
M1307.4.3
Fire
Fire
M1307.5
Electrical
Electrical |
- |
pdf_text |
| 13 |
13.
Exception: Limited area sprinkler systems installed in accordance with Section 9
the building subcode, shall be water pressure rated not less than 160 psig at 73° F.
vi. Section 3.12, Alternate Materials and Methods, shall be deleted in its entirety.
vii. In Table 3.1.3, Approved Materials, Part XI, Installation Procedures and Pract
insert: "11. Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Sp
Tubs, and Catch Basins: ANSI/APSN/ICC-7-2018." |
- |
pdf_text |
| 1301.1-1301.2 |
1301.1-1301.2
Fire/Plumbing
Fire (storage
systems) Plumbing
(Piping systems) |
- |
pdf_text |
| 1301.1-1301.2 |
1301.1-1301.2
Fire/Plumbing
Fire (storage
systems) Plumbing
(Piping systems) |
- |
pdf_text |
| 1301.3 |
1301.3
Fire
Fire |
- |
pdf_text |
| 1301.3 |
1301.3
Fire
Fire |
- |
pdf_text |
| 1301.4 |
1301.4
Fire/Plumbing
Fire (storage
systems) Plumbing
(Piping systems) |
- |
pdf_text |
| 1301.4 |
1301.4
Fire/Plumbing
Fire (storage
systems) Plumbing
(Piping systems) |
- |
pdf_text |
| 1301.5 |
1301.5
Fire
Fire |
- |
pdf_text |
| 1301.5 |
1301.5
Fire
Fire |
- |
pdf_text |
| 1302-1305 |
1302-1305
Plumbing
Plumbing |
- |
pdf_text |
| 1302-1305 |
1302-1305
Plumbing
Plumbing |
- |
pdf_text |
| 1306 |
1306
Fire
Fire |
- |
pdf_text |
| 1306 |
1306
Fire
Fire |
- |
pdf_text |
| 1307-1308 |
1307-1308
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 1307-1308 |
1307-1308
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 14 |
14
Cooling Equipment
M1401.1-M1401.3
Plumbing
Plumbing
M1401.4
Building/Plumbing
Plumbing, except for
proper support of the
equipment, which is
Building
M1401.5
Building/Plumbing
Plumbing
M1402.1-M1402.3
Electrical for electric
Electrical for
appliances/Plumbing for
electric
oil-fired appliances
appliances/Plumbing for
oil-fired appliances
M1403.1
Electrical
Electrical |
- |
pdf_text |
| 14 |
14. Appendix B of the mechanical subcode entitled "Recommended Permit Fee Sched
deleted in its entirety.
History
HISTORY:
R.1984 d.314, eff. August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b). |
- |
pdf_text |
| 14 |
14. A commercial farm building shall meet the fixture requirements of the plumbing s
except as follows:
i. A building within 500 feet of a structure with a restroom facility available for us
not be required to have plumbing fixtures; or
ii. A building operated on a seasonal basis, in use for no longer than six months w |
- |
pdf_text |
| 14 |
14
Exterior Walls
Building
Building |
- |
pdf_text |
| 14 |
14. At the beginning of Note b, insert "New Jersey is divided into two zones:
consists of Monmouth and Burlington Counties and all counties to the south; N
consists of Mercer and Middlesex Counties and all counties to the north."; |
- |
pdf_text |
| 14 |
14. Classification of the supervising station.
xxxix. In Section 907.2, Where required-new buildings and structures, Exception
have "fire code official" deleted and "fire protection subcode official" shall be inse
xl. Add new section 907.2.1.2 as follows:
"907.2.1.2 Group A-2 Nightclubs. An automatic fire detection system shall be
throughout all Group A-2 nightclubs with an occupant load of 100 or more. If t
is activated by smoke detectors, it shall be activated by either two cross-zoned
detectors within a single protected area or a single smoke detector monitored b
alarm verification zone or an approved equivalent method and the smoke detec
shall be of a type designed to reduce the possibility of false notifications based
conditions present in the area protected. The automatic fire detection system sh
tied to the performance sound system and to the house lights in such a way that
activation of the fire detection system mutes the performance sound system an
restores the intensity of illumination to that required by Section 1008.2.1.
Exception: Automatic fire detection systems are not required in buildings
with an automatic sprinkler system throughout." |
- |
pdf_text |
| 14 |
14. Appendix D, "Clean Air Delivery," and Appendix E, "Clean Air Delivery and
Monitoring," shall be optional at the discretion of the permit applicant.
History |
- |
pdf_text |
| 14 |
14. Chapter 15, Roof Assemblies and Rooftop Structures, shall be amended as follow
i. In Section 1502.1, General, "Chapter 11 of the International Plumbing Code" sh
deleted and "the plumbing subcode, N.J.A.C. 5:23-3.15" shall be inserted.
ii. In Section 1502.2, Secondary (emergency overflow) drains or scuppers, "Chapt
the International Plumbing Code" shall be deleted and "the plumbing subcode, N.J |
- |
pdf_text |
| 14 |
14 listed in Chapter 35 are not subject to this requirement. |
- |
pdf_text |
| 14 |
14
Heating and
Cooling
Equipment
M1401.1-M1401.3
Plumbing
Plumbing
M1401.4
Building/Plumbing
Plumbing, except for
proper support of the
equipment, which is
Building
M1401.5
See R306.1.6
See R306.1.6
M1402.1-M1402.3
Electrical for electric
Electrical for
appliances/Plumbing for
electric
oil-fired appliances
appliances/Plumbing for
oil-fired appliances
M1403.1
Electrical
Electrical
M1404.1
Plumbing
Plumbing
M1405-M1406.5
Electrical
Electrical
M1407.1-M1407.4
Building/Fire
Building
M1407.5
Electrical
Electrical
M1408-M1410
Building/Fire
Fire
M1411-M1413
Plumbing
Plumbing
M1414
Building/Fire
Fire
M1415
See R1002
See R1002
Ch. |
- |
pdf_text |
| 14 |
14. In section 705.7, "Placement", delete subsections 705.7.1, "Perpendicular
ramps;" 705.7.2, "Parallel curb ramps;" 705.7.3, "Blended transitions;" 705.7.4
"Pedestrian refuge islands;" 705.7.5 "Pedestrian at-grade rail crossings;" and 7
'Boarding and alighting areas" in their entirety; |
- |
pdf_text |
| 14 |
14. Chapter 18, Chimney and Vents, shall be amended as follows:
i. In Section M1801.3.2, Flue passageways, in the first sentence, "free of obstructi
combustible deposits" shall be deleted and "inspected in accordance with the chim
verification program as provided for in N.J.A.C. 5:23-2.20(d)" shall be inserted. |
- |
pdf_text |
| 14 |
14
Facilities
C
h.
Tests and Maintenance
Plumbi
ng
Plumbing |
- |
pdf_text |
| 14 |
14
Facilities
C
h.
Tests and Maintenance
Plumbi
ng
Plumbing |
- |
pdf_text |
| 14 |
14. Chapter 18, Chimney and Vents, shall be amended as follows: |
- |
pdf_text |
| 14 |
14. Chapter 17 of the plumbing subcode entitled, "Potable Water Supply Systems," sh
deleted and the following shall be inserted:
i. "17.1 General. On-site water supply systems are under the jurisdiction of the De
of Environmental Protection and county or local boards of health, as applicable." |
- |
pdf_text |
| 14 |
14. Chapter 15, Roof Assemblies and Rooftop Structures, shall be amended as follow |
- |
pdf_text |
| 14 |
14
Solar Thermal Systems |
- |
pdf_text |
| 14 |
14. At the beginning of Note b, insert "New Jersey is divided into two zones:
consists of Monmouth and Burlington Counties and all counties to the south; N
consists of Mercer and Middlesex Counties and all counties to the north." In ad
the last sentence "The jurisdiction shall fill in the frost line depth column with
minimum depth of footing below finish grade." shall be deleted. |
- |
pdf_text |
| 1401.2-1401.4 |
1401.2-1401.4
Plumbing
Plumbing |
- |
pdf_text |
| 1401.2-1401.4 |
1401.2-1401.4
Plumbing
Plumbing |
- |
pdf_text |
| 1402.1-1402.2 |
1402.1-1402.2
Building
Building |
- |
pdf_text |
| 1402.1-1402.2 |
1402.1-1402.2
Building
Building |
- |
pdf_text |
| 1402.3-1402.5 |
1402.3-1402.5
Plumbing
Plumbing |
- |
pdf_text |
| 1402.3-1402.5 |
1402.3-1402.5
Plumbing
Plumbing |
- |
pdf_text |
| 1402.6-1402.8.2 |
1402.6-1402.8.2
Building
Building |
- |
pdf_text |
| 1402.6-1402.8.2 |
1402.6-1402.8.2
Building
Building |
- |
pdf_text |
| 1402.8.3-1402.8.7 |
1402.8.3-1402.8.7
Plumbing
Plumbing |
- |
pdf_text |
| 1402.8.3-1402.8.7 |
1402.8.3-1402.8.7
Plumbing
Plumbing |
- |
pdf_text |
| 1403 |
1403
Plumbing/Fire
Plumbing |
- |
pdf_text |
| 1403 |
1403
Plumbing/Fire
Plumbing |
- |
pdf_text |
| 1404 |
1404
Plumbing
Plumbing
App
x.
Clean Air Delivery
Building
Building
D
App
x.
Clean Air Delivery and
Building
Building
E
Monitoring |
- |
pdf_text |
| 1404 |
1404
Plumbing
Plumbing |
- |
pdf_text |
| 15 |
15. Chapter 18 of the plumbing subcode, entitled Referenced Standards, shall be ame
follows:
i. At Section 18.2, Standards Organizations, shall be amended as follows:
(1) At "ICC," insert "As applicably adopted at N.J.A.C. 5:23-3, Subcodes." aft
contact information.
(2) Insert "Pool & Hot Tub Alliance (Formally APSP--The Association of Poo
Spa Professionals), 2111 Eisenhower Avenue, Ste. 500, Alexandria, VA 22314 |
- |
pdf_text |
| 15 |
15
Exhaust Systems |
- |
pdf_text |
| 15 |
15
Roof Assemblies and
Building
Building
Rooftop Structures
Ch. |
- |
pdf_text |
| 15 |
15. Chapter 20, Boilers/Water Heaters, shall be amended as follows:
i. In Sections M2004.1, General, and M2005.1, General, "Chapter 28" shall be del
"the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
ii. In Section M2005.3, Electric water heaters, "Chapters 34 through 43" shall be
and "the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 15 |
15. Sections 804.5.2, entitled "Operable Parts," 804.5.3, entitled "Dishwasher, |
- |
pdf_text |
| 15 |
15 shall be considered a reference to the appropriate plumbing subcode at N.J.A.C. 5:
energy subcode at N.J.A.C. 5:23-3.18, or the rehabilitation subcode at N.J.A.C. 5:23-6
respectively. |
- |
pdf_text |
| 15 |
15. Chapter 20, Boilers/Water Heaters, shall be amended as follows:
i. At Section M2002.4.1, Requirements for discharge pipe, item 13, "materials ind
Section P2906.5 or" shall be deleted.
ii. In Sections M2004.1, General, and M2005.1, General, "Chapter 28" shall be de
and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
iii. In Section M2005.3, Electric water heaters, "Chapters 34 through 43" shall be
and "the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 15 |
15. Chapter 16, Structural Design, shall be amended as follows:
i. New Section 1603.2, Restrictions on loading, from Section 1603.2 of the 2006
International Building Code, shall be inserted as follows: "It shall be unlawful to p
cause to permit to be placed, on any floor or roof of a building, structure or portion
a load greater than is permitted by these requirements."
ii. In Section 1607.8.5, Posting, "Section 106.1" shall be deleted and "the administ
provisions of the Uniform Construction Code (N.J.A.C. 5:23)" shall be inserted.
iii. Section 1607.12, Reduction in uniform live loads, shall be amended as follows
first sentence, "and applied" shall be inserted after "reduced." After the first senten
method chosen shall be applied throughout the building." shall be inserted.
iv. In Section 1611.1, Design rain load, the second and third sentences shall be del
"The design rainfall rates shall be based on the plumbing subcode, N.J.A.C. 5:23-3
shall be inserted.
v. In Section 1611, Rain loads, Figures 1611.1(1) through 1611.1(5), "100-year, 1
rainfall (inches)" shall be deleted.
vi. In Section 1612.1, General, in the first sentence, "including substantial improv
and restoration of substantial damage to buildings and structures" shall be deleted.
vii. In Section 1612.4, Flood hazard documentation, items 1.1 and 2.1, "Section 1
and "Section 110.3.12.1" shall be deleted and "the administrative provisions of the
Uniform Construction Code (N.J.A.C. 5:23)" shall be inserted in |
- |
pdf_text |
| 15 |
15
C
h.
Regulations Governing Individual
Plumbi
ng
Plumbing |
- |
pdf_text |
| 15 |
15. Chapter 16, Structural Design, shall be amended as follows:
i. New Section 1603.2, Restrictions on loading, from Section 1603.2 of the 2006
International Building Code, shall be inserted as follows: "It shall be unlawful to p |
- |
pdf_text |
| 15 |
15. At the beginning of Note g, insert "See the local floodplain administrator ( |
- |
pdf_text |
| 15 |
15
C
h.
Regulations Governing Individual
Plumbi
ng
Plumbing |
- |
pdf_text |
| 15 |
15,000 square feet of floor area and fraction thereof;
iii. In lieu of the requirements of Section 1013, exit signs must be posted. Exit sig
not required to be illuminated;
iv. The provisions of Section 1008 shall apply in commercial farm buildings wher
owner has determined to provide electricity. Where electricity is provided, any ele
light provided in the commercial farm building shall be deemed to meet the means
egress lighting requirements and a back up power source shall not be required unle
commercial farm building will be used as a place of public assembly in accordanc
(d)8 above.
v. In lieu of the requirements of Section 1004, occupancy is limited to 30 people;
vi. Fire extinguishers and "no smoking" signs shall be provided;
vii. Offices with 10 or fewer occupants and a floor area not in excess of 1,200 squ
shall be considered incidental to the structure, if direct exit to the exterior is provid |
- |
pdf_text |
| 15 |
15. Chapter 18 of the plumbing subcode, entitled Referenced Standards, shall be ame
follows:
i. In Section 18.2, Standards Organizations, insert the following: "Pool & Hot Tub
Alliance (Formally APSP--The Association of Pool and Spa Professionals), 2111
Eisenhower Avenue, Ste. 500, Alexandria, VA 22314, tel: 703-838-0083, fax: 703 |
- |
pdf_text |
| 15 |
15
Rooftop Structures
C
h.
Structural Design,
Building
Building |
- |
pdf_text |
| 15 |
15
Systems
M1501-M1502
Building/Fire
Building
M1503
Building/Fire
Fire
M1504
Building
Building
M1505
Building
Building
Ch.
Duct Systems |
- |
pdf_text |
| 15 |
15. At the beginning of Note g, insert "See the local floodplain administrator (
iii. Section R301.2.1.5, Topographic wind effects, shall be deleted, along with its
subsections, tables and figures.
iv. Section R301.2.2, Seismic provisions, shall be deleted, along with its subsectio
tables, and figures and the following shall be inserted: "Detached one- and two-fa
dwellings and attached single-family townhouses are exempt from the seismic
requirements of this code."
v. Section R301.2.4, Floodplain Construction, "repair" shall be deleted and "restor
shall be inserted. Also, Section R301.2.4.1, Alternative provisions, shall be deleted
entirety.
vi. In Table R301.5, Minimum Uniformly Distributed Live Loads, delete "Balconi
(exterior) and" from the fourth row. Insert a new row below "Decks" with "Exterio
Balconies" in the "Use" column and "60" in the "Uniform Load" column. |
- |
pdf_text |
| 15 |
15 days in a calendar year and that is provided with electricity shall comply with S |
- |
pdf_text |
| 15 |
15 days in a calendar year. For the purposes of enforcing this requirement, a public ass
shall be a gathering of 50 or more people. A permit shall be obtained from the local fir
official pursuant to the Uniform Fire Safety Act, N.J.S.A. 52:27D-192 et seq., and the
issuing the permit shall not exceed $ 75.00 per event.
i. A commercial farm building that is used as a place of public assembly for not m |
- |
pdf_text |
| 15 (cont. 2) |
all instances. |
- |
pdf_text |
| 16 |
16. Appendix A of the plumbing subcode, entitled "Sizing Storm Drainage Systems,"
deleted in its entirety. |
- |
pdf_text |
| 16 |
16
Sewage Disposal Systems for Homes and
Other Establishments Where Public Sewage
Systems Are Not Available.
A
p.
B
Sizing the Building Water Supply and
Plumbi
ng
Plumbing
Distribution Piping System
A
p.
C
Conversions: Metric to U.S. Customary
Plumbi
ng
Plumbing
Units
A
p.
D
Determining the Minimum Number of
Plumbi
ng
Plumbing
Required Plumbing Fixtures
A
p.
E
Special Design Plumbing Systems
n
Plumbi
ng
Plumbing
A
p.
F
Requirements of the Adopting Agency
Plumbi
ng
Plumbing
A
p.
H
Combined Building Drain and Building
Plumbi
ng
Plumbing
Sewers
A
p.
I
Flow in Horizontal Sanitary Drain
Plumbi
ng
Plumbing
Piping
A
An Acceptable Brazing Procedure for
Plumbi
Plumbing |
- |
pdf_text |
| 16 |
16. Chapter 21, Hydronic Piping, shall be amended as follows:
i. In Section M2101.2, System drain down, "Chapters 25 through 32 of this code"
deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
ii. In Sections M2101.3, Protection of potable water, M2101.25, Protection of pot
water, and M2105.18, Protection of potable water, "Section P2902" shall be delete
"the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
iii. In Sections M2101.16 and M2105.9, both entitled CPVC plastic pipe, "Section
P2906.9.1.2" shall be deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)" sh
inserted. In addition, in Sections M2101.21 and M2105.14, both entitled PVC plas
"Section P2906.9.1.4" shall be deleted and "the plumbing subcode (N.J.A.C. 5:23-
shall be inserted.
iv. In Section M2103.3, Piping joints, in Item #2, "Section P3003.6.1" shall be del
"the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
v. In Sections M2101.26, Pipe penetrations, and M2105.19, Pipe penetrations, "Se
P2606.1" shall be deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall b
inserted. |
- |
pdf_text |
| 16 |
16. Chapter 17, Structural Tests and Special Inspections, shall be amended as follows
i. In the User notes, under About this Chapter, "or construction official, as indicat
Chapter 17" shall be inserted after "building official." Additionally, "chapter 1" sh |
- |
pdf_text |
| 16 |
16. Delete section 805.2 "Bus boarding and alighting areas" in its entirety; |
- |
pdf_text |
| 16 |
16. Chapter 17, Special Inspections and Tests, shall be amended as follows:
i. In Section 1701.1, Scope, "shall apply to Class 1 buildings, mass timber eleme
Type IV-A, IV-B, and IV-C construction, and smoke control systems in all buildin
shall be inserted after "chapter."
ii. Section 1703.1, Approved agency, shall be amended as follows: In the first sen
"Upon the request of the construction official" shall be inserted before "An." In the
sentence, "building official" shall be deleted and "construction official" shall be in
and "applicable" shall be deleted and "following" shall be inserted.
iii. In Section 1703.1.1, Independence, in the second sentence, "building official"
deleted and "construction official" shall be inserted. Additionally, "registered desi
professional" shall be deleted and "person" shall be inserted.
iv. Add new section 1703.1.4 as follows: "1703.1.4 Certification. An approved ag
shall employ personnel certified in accordance with the administrative provisions
Uniform Construction Code, to conduct, supervise and evaluate tests or inspection
v. At Section 1703.3, Record of approval, in the first sentence, "building official's
be deleted and "construction official" shall be inserted.
vi. In Section 1703.4, Performance, in the first sentence, "building official" shall
deleted and "construction official" shall be inserted.
vii. In Section 1703.4.1, Research and investigation, in the first and second sente
"building official" shall be deleted |
- |
pdf_text |
| 16 |
16
Structural Design,
Building
Building
except 1612.4 |
- |
pdf_text |
| 16 |
16
Duct Systems
M1601.1
Building
Building
M1601.1.1-
M1601.6
Building/Fire
Building
M1602
Building/Fire
Building
Ch. |
- |
pdf_text |
| 16 |
16
Sewage Disposal Systems for Homes and
Other Establishments Where Public Sewage
Systems Are Not Available.
A
pp
x.
Sizing the Building Water Supply and
Plumbi
ng
Plumbing
B
Distribution Piping System
A
pp
x.
Conversions: Metric to U.S. Customary
Plumbi
ng
Plumbing
C
Units
A
pp
x.
Determining the Minimum Number of
Plumbi
ng
Plumbing
D
Required Plumbing Fixtures
A
pp
x.
Special Design Plumbing Systems
Plumbi
ng
Plumbing
E
A
pp
x.
Requirements of the Adopting Agency
Plumbi
ng
Plumbing
F
and Authority Having Jurisdiction
A
pp
x.
Combined Building Drain and Building
Plumbi
ng
Plumbing |
- |
pdf_text |
| 16 |
16
M1601.1
Building
Building
M1601.1.1-M1601.6
Building/Fire
Building
M1602
Building/Fire
Building
Ch.
Combustion Air
Fire
Fire |
- |
pdf_text |
| 16 (cont. 2) |
and "construction official" shall be inserted.
viii. At Section 1703.6, Evaluation and follow-up inspection services, "in accorda
N.J.A.C. 5:23-4.26" shall be inserted at the end of the first sentence. Additionally, |
- |
pdf_text |
| 1612.2 |
1612.2
Building,
Building, except as
except as
applicable based on equipment
applicable
based
on equipment
C
h.
Structural Tests and |
- |
pdf_text |
| 1612.4 |
1612.4
Building,
Building, except as
except as
applicable based on
applicable
based
equipment
on equipment
Ch. |
- |
pdf_text |
| 17 |
17
Ch.
Chimneys and |
- |
pdf_text |
| 17 |
17
Structural Tests and
Special Inspections |
- |
pdf_text |
| 17 |
17. Chapter 18, Soils and Foundations, shall be amended as follows:
i. Section 1803.3.1, Scope of investigation, shall be amended as follows: After th
sentence, the following sentence from Section 1802.1 of the 1996 BOCA National
Building Code shall be inserted: "There shall be at least one exploratory boring to
to an adequate depth below the load-bearing strata for every 2,500 square feet (232
built-over area, and such additional tests as the code official requires."
ii. In Section 1803.5, Investigated conditions, in the last line, delete "1803.5.12" a
insert "1803.5.13".
iii. In the title of Section 1803.5.11, "C" shall be deleted and "D" shall be inserted
first sentence, "C," shall be deleted.
iv. New Section 1803.5.13 from Section 1802.1 of the 1996 BOCA National Buil
Code shall be inserted as follows: "Building Height: For all buildings that are mor
three stories or 40 feet (12,192 mm) in height above the grade plane, the building
shall request soil tests."
v. In Section 1805.4.3, Drainage discharge, "International Plumbing Code" shall
deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
vi. Sections 1807.2.5, Guards, 1807.2.5.1, Where required, 1807.2.5.2, Height, an |
- |
pdf_text |
| 17 |
17. Delete section 808, "Enhanced acoustics for classrooms" in its entirety; |
- |
pdf_text |
| 17 |
17
Combustion Air
Fire
Fire
Ch. |
- |
pdf_text |
| 17 |
17. Appendix E of the plumbing subcode, entitled "Special Design Plumbing Systems
be amended as follows:
i. Section E.9.3, Rainfall Rates, shall be deleted and the following shall be inserte
"Rainfall rates shall be applied so that the applicable rainfall rates for Burlington a
Ocean counties and all counties south, shall be six (6) inches per hour; for Mercer
Monmouth counties and all counties north, the applicable rainfall rate shall be five
inches per hour."
ii. Section E.9.4, Secondary Roof Drainage, shall be deleted.
iii. Section E.10.2, Rainfall Rates, shall be deleted and the following shall be inser
"Rainfall rates shall be applied so that the applicable rainfall rates for Burlington a
Ocean counties and all counties south, shall be six (6) inches per hour; for Mercer
Monmouth counties and all counties north, the applicable rainfall rate shall be five
inches per hour."
iv. Section E.10.3, Secondary Roof Drainage, shall be deleted. |
- |
pdf_text |
| 17 |
17. Appendix E of the plumbing subcode, entitled "Special Design Plumbing Systems
be amended as follows:
i. Section E.9.3, Rainfall Rates, shall be deleted and the following shall be inserte
"Rainfall rates shall be applied so that the applicable rainfall rates for Burlington a
Ocean counties and all counties south, shall be six (6) inches per hour; for Mercer
Monmouth counties and all counties north, the applicable rainfall rate shall be five
inches per hour."
ii. Section E.9.4, Secondary Roof Drainage, shall be deleted. |
- |
pdf_text |
| 17 |
17
Special Inspections |
- |
pdf_text |
| 17 |
17. Chapter 18, Soils and Foundations, shall be amended as follows:
i. Section 1803.3.1, Scope of investigation, shall be amended as follows: After the
sentence, the following sentence from Section 1802.1 of the 1996 BOCA National
Building Code shall be inserted: "There shall be at least one exploratory boring to
to an adequate depth below the load-bearing strata for every 2,500 square feet (232
built-over area, and such additional tests as the code official requires."
ii. In Section 1803.5, Investigated conditions, in the last line, delete "1803.5.12" a
"1803.5.13".
iii. In the title of Section 1803.5.11, "C" shall be deleted and "D" shall be inserted
first sentence, the reference to "C" shall be deleted.
iv. New Section 1803.5.13 from Section 1802.1 of the 1996 BOCA National Buil
Code shall be inserted as follows: "Building Height: For all buildings that are mor
three stories or 40 feet (12,192 mm) in height above the grade plane, the building
shall request soil tests."
v. In Section 1805.4.3, Drainage discharge, "International Plumbing Code" shall b
deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
vi. New Section 1807.4 from Section 1813.8 of the 1996 BOCA National Buildin
shall be inserted as follows: "1807.4 Erosion protection: Where water impacts the
from the edge of the roof, downspout, scupper or other rain water collection or div
device, provisions shall be made to prevent soil erosion and direct the water away
foundation."
vii. Sect |
- |
pdf_text |
| 17 |
17. Chapter 22, Special Piping and Storage Systems shall be amended as follows:
i. In Section M2201.2, Above-ground tanks, in the first sentence and in the except
"above ground or" shall be deleted and "residential" shall be inserted before "build |
- |
pdf_text |
| 17 (cont. 2) |
ion 1809.4, Depth and width of footings, shall have the following excepti
added:
"Exceptions: |
- |
pdf_text |
| 1701.1-1705.18.2 |
1701.1-1705.18.2
Building
Building |
- |
pdf_text |
| 1701.1-1705.18.2 |
1701.1-1705.18.2
Building
Building |
- |
pdf_text |
| 1705.19 |
1705.19
Fire
Fire |
- |
pdf_text |
| 1705.19 |
1705.19
Fire
Fire |
- |
pdf_text |
| 1705.20 |
1705.20
Building
Building |
- |
pdf_text |
| 1705.20 |
1705.20
Building
Building |
- |
pdf_text |
| 1705.5 |
1705.5.
xxv. In Table 1705.7, Required special inspections and test of driven deep founda
elements, at Item #7, "registered design professional" shall be deleted and "person
inserted.
xxvi. In Section 1705.9, Helical pile foundations, in the second sentence, "register
design professional" shall be deleted and "person" shall be inserted.
xxvii. Section 1705.12, Special inspection for wind resistance, shall be deleted.
xxviii. In Section 1705.13.1.1, Seismic force-resisting systems, "B and C," shall b
in reference to seismic design categories. Additionally, Exception 1 shall be delete |
- |
pdf_text |
| 1706.1-1709.7 |
1706.1-1709.7
Building
Building
C
h.
Soil and Foundations
Building
Building |
- |
pdf_text |
| 1706.1-1709.7 |
1706.1-1709.7
Building
Building
Ch. |
- |
pdf_text |
| 18 |
18. Chapter 23, Wood, shall be amended as follows:
i. In Section 2303.4.1.4.1, Truss design drawings, "Where required by the registe
design professional, the building official, or the statutes of the jurisdiction in whic
project is to be constructed," shall be deleted.
ii. In Section 2303.4.2, Truss placement diagram, in the last sentence, "that serve
guide for installation and do not deviate from the permit submittal drawings" shall
deleted.
iii. New Section 2303.4.8, entitled "Truss Identification," shall be inserted as foll
"Each truss shall be labeled or otherwise indelibly marked at the factory with the i
truss number as assigned in the truss layout plan. The indelible marking or label sh
located on the bottom chord of the truss, inside the bearing points. When indelible
markings are used, each digit shall be not less than one inch high. When labels are
the label shall be a minimum of five inches by three inches and shall be affixed to
by a truss plate. Labels shall remain affixed to the truss."
iv. In Table 2306.2(2), Allowable Shear Values (Pounds Per Foot) For Wood Str
Panel Blocked Diaphragms Utilizing Multiple Rows of Staples (High-Load Diaphr
With Framing of Douglas Fir-Larch or Southern Pine for Wind or Seismic Loadin
shall be deleted.
v. In Section 2308.1, General, the last sentence shall be deleted. |
- |
pdf_text |
| 18 |
18
Soil and Foundations
Building
Building
Ch. |
- |
pdf_text |
| 18 |
18
Chimneys and
Vents
M1801-M1804
Building/Fire
Fire for labeled
vents and factory-built
chimneys/Building for
masonry chimneys
M1805
Building/Fire (Masonry
Building (Masonry
Chimneys) Building/Fire
Chimneys) Fire
(Factory-built chimneys)
(Factory-Built chimneys)
Ch. |
- |
pdf_text |
| 18 |
18. Chapter 23, Solar Thermal Systems, shall be amended as follows:
i. In Section M2301.4, Heat transfer gasses or liquids and heat exchangers, "Secti
P2902.5.2" shall be deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall
inserted.
ii. In Sections M2301.5, Backflow protection, and M2301.7, Solar thermal system
heating potable water, "Section P2902.5.5" shall be deleted and "the plumbing sub
(N.J.A.C. 5:23-3.15)" shall be inserted.
iii. In Section M2301.7.1, Indirect systems, "Section P2902.5.2" shall be deleted a
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
iv. In Section M2301.7.2, Direct systems, "Chapter 29" shall be deleted and "the p
subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 18 |
18. Chapter 23, Wood, shall be amended as follows:
i. In Section 2303.4.1.4.1, Truss design drawings, "Where required by the register
design professional, the building official, or the statutes of the jurisdiction in whic
project is to be constructed," shall be deleted.
ii. In Section 2303.4.2, Truss placement diagram, in the last sentence, "that serve
guide for installation and do not deviate from the permit submittal drawings" shall
deleted.
iii. In Section 2303.4.6, TPI 1 specifications, "Section 110.4" shall be deleted and
administrative provisions of the Uniform Construction Code (N.J.A.C. 5:23)" shall
inserted.
iv. New Section 2303.4.8, entitled "Truss Identification," shall be inserted as follo
"Each truss shall be labeled or otherwise indelibly marked at the factory with the i
truss number as assigned in the truss layout plan. The indelible marking or label sh
located on the bottom chord of the truss, inside the bearing points. When indelible
markings are used, each digit shall be not less than one inch high. When labels are
the label shall be a minimum of five inches by three inches and shall be affixed to
by a truss plate. Labels shall remain affixed to the truss."
v. In Table 2304.10.2, Fastening Schedule, in footnote g, "under Section 104.11"
deleted, and "pursuant to N.J.A.C. 5:23-3.7" shall be inserted in its place.
vi. In Table 2306.2(2), Allowable Shear Values (Pounds Per Foot) For Wood Stru
Panel Blocked Diaphragms Utilizing Multiple Rows of Sta |
- |
pdf_text |
| 18 |
18. Appendix G, entitled "We-Stand Excerpts," shall not be adopted as part of the plu
subcode. Appendix G may be used as a reference standard for special design plumbing
in accordance with Appendix E. |
- |
pdf_text |
| 18 |
18. Delete section 1001.4, "Animal containment areas" in its entirety; |
- |
pdf_text |
| 18 |
18. Chapter 23, Solar Thermal Systems, shall be amended as follows:
i. In Section M2301.4, Heat transfer gasses or liquids and heat exchangers, "Secti
P2902.5.2" shall be deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall
inserted.
ii. In Sections M2301.5, Backflow protection, and M2301.7, Solar thermal system
heating potable water, "Section P2902.5.5" shall be deleted and "the plumbing sub
(N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 18 |
18
C
h.
Concrete
Building
Building |
- |
pdf_text |
| 18 (cont. 2) |
ples (High-Load Diaphr
With Framing of Douglas Fir-Larch or Southern Pine for Wind or Seismic Loadin
shall be deleted.
vii. In Section 2308.1, General, the last sentence shall be deleted. |
- |
pdf_text |
| 1807.5.2.3 |
1807.5.2.3, Opening limitations, shall be deleted in their entirety.
vii. New Section 1807.4 from Section 1813.8 of the 1996 BOCA National Buildi
shall be inserted as follows: "1807.4 Erosion protection: Where water impacts the |
- |
pdf_text |
| 19 |
19
Special
Fuel-Burning
Equipment
M1901
Building/Fire
Fire
M1902.1-M1902.2
Building
Building
M1902.3
Fire
Fire
M1902.4
Building
Building
M1903-M1904
Building/Fire
Fire
Ch. |
- |
pdf_text |
| 19 |
19. Appendix L, entitled "Tiny Houses," shall be adopted as part of this subcode. |
- |
pdf_text |
| 19 |
19
Concrete
Building
Building
Ch. |
- |
pdf_text |
| 19 |
19
C
h.
Aluminum
Building
Building |
- |
pdf_text |
| 19 |
19. Chapter 24, Fuel Gas, shall be amended as follows:
i. In Section G2402.3, Terms defined in other codes, "International Building Code
International Fire Code, and International Plumbing Code" shall be deleted and "el
building, fire protection, and plumbing subcodes" shall be inserted.
ii. Section G2403, entitled "General Definitions" shall be amended as follows:
(1) The definitions of "approved," "approved agency," "code," "code official"
"dwelling unit" shall be deleted.
iii. Section G2404.5, Repair, shall be deleted in its entirety.
iv. In Section G2408.1, General, the second paragraph shall be deleted in its entire
v. In Section G2410.2, Connections, "Chapters 34 through 43" shall be deleted an
Electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 19 |
19. Delete section 1002, "Amusement Rides", section 1003, "Recreational Bo
Facilities", section 1004, "Exercise Machines and Equipment", section 1005, "
Piers and Platforms", section 1006, "Golf Facilities", section 1007, "Miniature
Facilities", section 1008, "Play Areas", and section 1010, "Shooting Facilities
Firing Positions" in their entirety; |
- |
pdf_text |
| 19 |
19
Fuel-Burning
Equipment
M1901
Building/Fire
Fire
M1902.1-M1902.2
Building
Building
M1902.3
Fire
Fire
M1902.4
Building
Building
M1903-M1904
Building/Fire
Fire
Ch.
Boilers/Water
Plumbing
Plumbing |
- |
pdf_text |
| 19 |
19" shall be inserted in its place. |
- |
pdf_text |
| 19 |
19. Chapter 25, Gypsum Board, Gypsum Panel Products and Plaster, shall be amende
follows:
i. In Section 2503.1, Inspection, "Section 110.3.6" shall be deleted and "the admin
provisions of the Uniform Construction Code (N.J.A.C. 5:23)" shall be inserted. |
- |
pdf_text |
| 19 |
19. Chapter 24, Fuel Gas, shall be amended as follows:
i. In Section G2402.3, Terms defined in other codes, "International Building Code
International Fire Code, and International Plumbing Code" shall be deleted and "el
building, fire protection, and plumbing subcodes" shall be inserted.
ii. Section G2403, entitled "General Definitions" shall be amended as follows:
(1) The definitions of "approved," "approved agency," "code," "code official"
"dwelling unit" shall be deleted.
iii. In Section G2404.3, Listed and labeled, in the first sentence, "Section R104.11
be deleted and "N.J.A.C. 5:23-3.7" shall be inserted. In addition, the last sentence
deleted.
iv. Section G2404.5, Repair, shall be deleted in its entirety.
v. In Section G2408.1, General, the second paragraph shall be deleted in its entire
vi. In Section G2410.2, Connections, "Chapters 34 through 43" shall be deleted an
Electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
vii. Section G2412.2, Liquefied petroleum gas storage, shall be amended to add th
following: "Notwithstanding the provisions contained in NFPA 58, the installation
Gas containers on roofs of buildings shall be strictly prohibited."
viii. Section G2412.3, Modifications to existing system, shall be deleted in its enti
ix. Add new Section G2412.11 as follows: "G2412.11 (401.9) Protection from ve
impact. Gas meters, related regulators and piping that are installed indoors or outd
are subject to vehicle impact shall be prot |
- |
pdf_text |
| 19 |
19. Appendix L, entitled "Tiny Houses," shall be adopted as part of this subcode.
(c) A newly installed automatic lawn sprinkler system, where such systems are not prohib
local ordinance, shall be equipped with an automatic rain sensor device or switch that will
the irrigation cycle of the automatic lawn sprinkler system when rainfall of more than one
inch has occurred.
History
HISTORY:
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1983 d.12, eff. February 7, 1983, operative February 22, 1983. |
- |
pdf_text |
| 19 |
19. Chapter 27, Electrical, shall be amended as follows:
i. Section 2701.1, Scope, shall be deleted in its entirety. |
- |
pdf_text |
| 19 (cont. 2) |
ected by barriers meeting the requiremen |
- |
pdf_text |
| 2 |
2. Date the fabric was last treated with flame-resistant solution. |
- |
pdf_text |
| 2 |
2. Modifications to the subcodes adopted. |
- |
pdf_text |
| 2 |
2. Where the local fire department approves a single connection for a large
diameter hose of at least four inches (102 mm). |
- |
pdf_text |
| 2 |
2. Chapter 2 of the mechanical subcode, entitled "Definitions," is amended as follows
i. In Section 201.3, Terms defined in other codes, delete "International Plumbing
and insert "plumbing subcode (N.J.A.C. 5:23-3.15)."
ii. The definition of the term "alteration" is deleted.
iii. The definition of the term "approved" is deleted and the following shall be ins
"Approved refers to approval by the appropriate subcode official or other authority
jurisdiction in accordance with the regulations."
iv. In the definition of "Approved Agency," "or other authority having jurisdiction
accordance with the Uniform Construction Code" shall be inserted after "official."
v. The definition of the term "building" is deleted and the definition at N.J.A.C. 5: |
- |
pdf_text |
| 2 |
2. Any references to the International Plumbing Code or the International Existing Bu
Code throughout the code and listed at Chapter 44 shall be considered a reference to t
appropriate plumbing subcode at N.J.A.C. 5:23-3.15 or rehabilitation subcode at N.J.A |
- |
pdf_text |
| 2 |
2. Under the heading of "Wind Design--Speed," insert "see Bulletin 19-1"; |
- |
pdf_text |
| 2 |
2. Any references to the International Plumbing Code, the International Energy Conse
Code or the International Existing Building Code listed in Chapter 15 shall be conside
reference to the appropriate plumbing, or energy subcode in N.J.A.C. 5:23-3 or the
rehabilitation subcode in N.J.A.C. 5:23-6. |
- |
pdf_text |
| 2 |
2. The municipal code enforcing agency performing the construction code plan revie
require the payment of any municipal plan review fees. |
- |
pdf_text |
| 2 |
2. Any references to the International Plumbing Code or the International Existing Bu
Code listed in Chapter 8 shall be considered a reference to the appropriate plumbing s
in N.J.A.C. 5:23-3 or rehabilitation subcode in N.J.A.C. 5:23-6. |
- |
pdf_text |
| 2 |
2. Chapter 2, Definitions, shall be amended as follows:
i. The definition of "addition," shall be deleted. |
- |
pdf_text |
| 2 |
2. Any references to the International Plumbing Code, the International Energy Conse
Code, or the International Existing Building Code throughout this code and listed at C |
- |
pdf_text |
| 2 |
2. Locations of alarm-initiating devices. |
- |
pdf_text |
| 2 |
2. All school buildings shall be equipped with a mechanical air supply and exhaust ve
system which will provide, during periods of occupancy, standard tempered outdoor ai
and mechanical exhaust at the minimum rates set forth in the mechanical subcode.
(d) Pursuant to Reorganization Plan No. 114-1996, the Department or the municipal code
enforcing agency shall have authority to enforce and cite violations of N.J.A.C. 6A:26-6.3
and 8.1.
History
HISTORY:
Amended by R.1986 d.142, effective May 5, 1986.
See: 17 N.J.R. 1169(a), 18 N.J.R. 945(a).
New (a)7; old (a)7 through 9 renumbered (a)8.-10.
Administrative Change: This section was originally part of N.J.A.C. 5:23-3.11.
See: 18 N.J.R. 1842(a).
Amended by R.1988 d.155, effective April 4, 1988.
See: 20 N.J.R. 824(d).
Added (d). This was amended by the rule adoption of the Department of Education published in
Jersey Register at 20 N.J.R. 824(d).
Administrative Correction to (c).
See: 22 N.J.R. 2503(b).
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a). |
- |
pdf_text |
| 2 |
2. Chapter 2 of the fuel gas subcode, entitled "Definitions," is amended as follows:
i. In Section 201.3, Terms defined in other codes, delete "International Plumbing
and insert "the plumbing subcode (N.J.A.C. 5:23-3.15)."
ii. The definition of the term "alteration" is deleted.
iii. The definition of the term "approved" is deleted and the following shall be ins
"Approved refers to approval by the appropriate subcode official or other authority
jurisdiction in accordance with the regulations."
iv. In the definition of "approved agency," "or other authority having jurisdiction i
accordance with the Uniform Construction Code" shall be inserted after "official."
v. The definition of the term "code" is deleted.
vi. The definition of the term "code official" is deleted.
vii. In the definition of "dwelling unit," "living as a single housekeeping unit" shal
inserted after "persons."
viii. The definition of the term "peer review" is deleted.
ix. The definition of the term "unlisted boiler" is deleted. |
- |
pdf_text |
| 2 |
2. An automatic smoke detection system is not required in buildings that d
have interior corridors serving sleeping units and where each sleeping |
- |
pdf_text |
| 2 |
2. Where the local fire department approves a single connection for a large dia
hose of at least four inches (102 mm). |
- |
pdf_text |
| 2 |
2. The model code portions listed above may be known as "the fire protection subcod |
- |
pdf_text |
| 2 |
2. Chapter 2 of the fuel gas subcode, entitled "Definitions," is amended as follows:
i. In Section 201.3, Terms defined in other codes, delete "International Plumbing
and insert "the plumbing subcode (N.J.A.C. 5:23-3.15)."
ii. The definition of the term "alteration" is deleted.
iii. The definition of the term "approved" is deleted and the following shall be ins
"Approved refers to approval by the appropriate subcode official or other authority
jurisdiction in accordance with the regulations."
iv. In the definition of "approved agency," "or other authority having jurisdiction i
accordance with the Uniform Construction Code" shall be inserted after "official."
v. The definition of the term "code" is deleted.
vi. The definition of the term "code official" is deleted.
vii. In the definition of "dwelling unit," "living as a single housekeeping unit" shal
inserted after "persons."
viii. The definition of the term "unlisted boiler" is deleted. |
- |
pdf_text |
| 2 |
2. "The National Standard Plumbing Code Illustrated/2021," including appendices, m
known, and cited as "the plumbing subcode."
(b) The following pages, chapters, sections, or appendices of the plumbing subcode shall
amended as follows: |
- |
pdf_text |
| 2 |
2. Are otherwise within the plan review jurisdiction of the local enforcing agency.
(c) A permit shall not be issued until the required plans for the building or structure have
released by the department. The Department shall insure that the municipal enforcing age
receives a copy of the released plans. |
- |
pdf_text |
| 2 |
2. Public welfare and safety are assured; and |
- |
pdf_text |
| 2 |
2. Chapter 2, Definitions, shall be amended as follows: |
- |
pdf_text |
| 2 |
2. Garden-type utility sheds and similar structures that are greater than 100 sq
feet, but not more than 200 square feet in area, 10 feet or less in height and acc
structures of Group R-2, R-3 or R-4 provided the shed is dimensionally stable
the foundation system and does not contain a water, gas, oil or sewer connectio
shed shall be considered dimensionally stable if it is provided with a floor syst
is tied to the walls of the structure such that it reacts to loads as a unit. These st
shall be of sufficient weight to remain in place or shall be anchored to the grou
ix. New Section 1810.3.1.7 from Section 1816.9 of the 1996 BOCA National Bui
Code shall be inserted as follows: "Spacing. The minimum center-to-center spacin
shall not be less than twice the average diameter of a round pile, nor less than 1 3/
the diagonal dimension of a rectangular pile. Where driven to or penetrating into r
spacing shall not be less than 24 inches (610 mm). Where receiving principal supp
end from materials other than rock, or through friction resistance, the spacing shall
less than 30 inches (762 mm) except that for piles having enlarged bases formed ei
compacting concrete or driving a pre-cast base, the minimum center-to-center spac
be 4 1/2 feet (1,372 mm). The spacing of piles shall be such that the average load |
- |
pdf_text |
| 2 |
2. The text at Section 106.2, entitled "Documents," shall be amended as follo |
- |
pdf_text |
| 2 |
2. Chapter 2, Definitions, shall be amended as follows:
i. The definition of "Addition" shall be deleted. |
- |
pdf_text |
| 2 |
2. Tanks with a capacity of 2,000 gallons or less used to store heating oil for onsite
consumption in a nonresidential building; |
- |
pdf_text |
| 2 |
2. Chapter 2, Definitions, shall be amended as follows:
i. In Section R201.3, Terms defined in other codes, "International Plumbing Code
be deleted and "National Standard Plumbing Code" shall be inserted.
ii. The definitions of "Addition" and "Alteration" shall be deleted.
iii. The definition of "Approved" shall be deleted and the following shall be insert
"Approved refers to approval by the appropriate subcode official or other authority
jurisdiction in accordance with the regulations."
iv. In the definition of "Approved Agency," "or other authority having jurisdiction
accordance with the Uniform Construction Code" shall be inserted after "official."
v. The definition of "Building" shall be deleted and the definition at N.J.A.C. 5:23 |
- |
pdf_text |
| 2 |
2. Date the fabric was last treated with flame-resistant solution. Date the fabri
last treated with flame-resistant solution. |
- |
pdf_text |
| 2 |
2. The wet vent shall be larger than 1/2 the size of the drain for the
drain or floor sink. |
- |
pdf_text |
| 2 |
2. Equivalent facilitation, such as a folding shelf attached to the main service c
or space at the side of the service counter."
lii. In Section 1111.2.2, Facilities serving Type A and Type B units in a single bui
delete "and Type B" in the title and "or Type B" in the first sentence.
liii. In Section 1111.2.3, Facilities serving Type A and Type B units in multiple b
delete "and Type B" in the title and "or Type B" in the first sentence.
liv. Sections 1111.4.8, Amusement rides, 1111.4.8.1, Load and unload areas, 111
Wheelchair spaces, ride seats designed for transfer and transfer devices, and 1111.
Minimum number shall be deleted in their entirety.
lv. Sections 1111.4.12, Miniature golf facilities, 1111.4.12.1, Minimum number, |
- |
pdf_text |
| 2 |
2. Standpipe hose connections for systems required by Section 905.3.1A shall
permitted to be located only at exits such that all portions of the building floor
not more than 200 feet (60,960 mm) from a hose connection or 200 feet (122
the nearest point of fire department vehicle access." |
- |
pdf_text |
| 2 |
2,000" shall be inserted. |
- |
pdf_text |
| 2 |
2. Dry standpipe systems installed in open parking structures.
xxvii. New Section 905.3.2 shall be inserted as follows:
"905.3.2 Building area. In buildings exceeding 10,000 square feet (929 m<2>)
per story, Class I automatic wet or manual wet standpipes shall be provided wh
portion of the building's interior area is more than 200 feet (60,960 mm) of tra
vertically and horizontally, from the nearest point of fire department vehicle ac
Exceptions: |
- |
pdf_text |
| 2 |
2. Ski lifts; |
- |
pdf_text |
| 2 |
2. Chapter 2, Definitions, shall be deleted, except that a new definition of "IECC-Co
Provisions" shall be inserted and defined as meeting "the requirements of the ASHRA
Standard 90.1 referenced by Chapter 6 of commercial provisions of this code." |
- |
pdf_text |
| 2 |
2. Garden-type utility sheds and similar structures that are greater than 100 sq
but not more than 200 square feet in area, 10 feet or less in height and accessor
structures of Group R-2, R-3 or R-4 provided the shed is dimensionally stable
the foundation system and does not contain a water, gas, oil or sewer connectio
shed shall be considered dimensionally stable if it is provided with a floor syst
is tied to the walls of the structure such that it reacts to loads as a unit. These st
shall be of sufficient weight to remain in place or shall be anchored to the grou
viii. New Section 1810.3.1.7 from Section 1816.9 of the 1996 BOCA National Bu
Code shall be inserted as follows: "Spacing. The minimum center-to-center spacin
shall not be less than twice the average diameter of a round pile, nor less than 1 3/
the diagonal dimension of a rectangular pile. Where driven to or penetrating into r
spacing shall not be less than 24 inches (610 mm). Where receiving principal supp
end from materials other than rock, or through friction resistance, the spacing shall
less than 30 inches (762 mm) except that for piles having enlarged bases formed ei
compacting concrete or driving a pre-cast base, the minimum center-to-center spac
be 4 1/2 feet (1,372 mm). The spacing of piles shall be such that the average load
supporting strata will not exceed the safe load-bearing value of those strata as dete
by test borings or other approved methods."
ix. In Section 1810.3.3.1.3, Load test evaluatio |
- |
pdf_text |
| 2 |
2. "The National Standard Plumbing Code/2024," including appendices, may be know
cited as "the plumbing subcode."
(b) The following pages, chapters, sections, or appendices of the plumbing subcode shall
amended as follows: |
- |
pdf_text |
| 2 |
2. An automatic smoke detection system is not required in buildings that d
have interior corridors serving sleeping units and where each sleeping unit
means of egress door opening directly to an exit or to an exterior exit acces
leads directly to an exit.
xli. In Section 907.4.2.5, Protective covers, "fire code official" shall be delete
"fire protection subcode official" shall be inserted.
xlii. Section 907.5.2.2.5, Standby power, shall be deleted, and Section 907.5.2
the IBC/2018 shall be inserted as follows: |
- |
pdf_text |
| 2 |
2. Chapter 2, Definitions, shall be amended as follows: |
- |
pdf_text |
| 2 |
2. Chapter 1 of the plumbing subcode, entitled "Definitions," shall be amended as foll
i. Delete the term and definition of "Adopting Agency."
ii. Amend the definition of "approved" as follows: delete "Sec. 3.12" and insert " |
- |
pdf_text |
| 2 |
2. Chapter 2, Definitions, shall be amended as follows:
i. The definition of "Addition" shall be deleted.
ii. The definition of "Alteration" shall be deleted.
iii. The definition of "Approved" shall be deleted and the following shall be insert
"Approved refers to approval by the appropriate subcode official or other authority
jurisdiction in accordance with the regulations."
iv. In the definition of "Approved Agency," "by the authority having jurisdiction i
accordance with the Uniform Construction Code" shall be inserted after "approved
addition, the last sentence "For the definition applicable in Chapter 24, see Section
G2403." shall be deleted.
v. The definition of "Attic, habitable" shall be deleted and the following shall be i
"An attic that has a stairway as a means of access and egress and in which the cei
at a height of seven feet above the attic floor is not more than one-third the area of
floor below."
vi. The definition of "Building" shall be deleted and the following shall be inserte
"BUILDING. A structure enclosed with exterior walls or fire walls, built, ere
framed of component structural parts, designed for the housing shelter, enclo
support of individuals, animals or property of any kind. When used herein, buil
structure shall be interchangeable except where the context clearly indicates other
vii. The definition of "Building, Existing" shall be deleted.
viii. The definition of "Building Line" shall be deleted.
ix. The definitions of |
- |
pdf_text |
| 2 |
2. Any references to the International Plumbing Code or the International Existing Bu
Code listed in Chapter 35 shall be considered a reference to the plumbing subcode, N. |
- |
pdf_text |
| 2 |
2. Dry standpipe systems installed in open parking structures." |
- |
pdf_text |
| 2 |
2. The model code portions listed above may be known as "the fire protection subcod
History
HISTORY: |
- |
pdf_text |
| 2 |
2. Code change proposals to other State-developed subcodes shall be submitted to the
Development Unit in accordance with (b)4 above. |
- |
pdf_text |
| 2 |
2. Reports of engineering findings issued by nationally recognized evaluation service
programs, such as, but not limited to, the Building Officials and Code Administrators
the International Conference of Building Officials (ICBO), the Southern Building Cod
Congress International (SBCCI), the International Code Council (ICC), and the Nation
Evaluation Service, Inc., shall be accepted by the appropriate subcode official as meeti
requirements of (a) above. The materials, equipment, or assembly shall be installed in
accordance with the conditions specified in the report.
(b) Research and investigations: The appropriate subcode official shall require that suffici
technical data be submitted to substantiate the proposed use of any material or assembly, a
is determined that the evidence submitted is satisfactory proof of performance for the use i |
- |
pdf_text |
| 2 |
2. A limited use/limited application elevator that complies with ANSI/ASME
adopted by reference in the building subcode shall be allowed to provide a vert
accessible route in the following buildings or tenancies, provided that the trave
distance of the device does not exceed 25 feet: |
- |
pdf_text |
| 2 |
2. The distance from the outlet of the water closet to the connectio
wet vent is within the limits established by Section 12.8.4. Otherwi
water closet shall be individually vented. |
- |
pdf_text |
| 2 |
2. In buildings where limited area sprinkler systems are supplied with wat
common standpipe riser, the riser shall be sized to satisfy total demand. |
- |
pdf_text |
| 2 |
2. Accessory garden-type utility sheds and similar structures that are greater th
square feet, but not more than 200 square feet in area, and 10 feet or less in hei
provided the shed is dimensionally stable without the foundation system and d
contain a water, gas, oil or sewer connection. A shed shall be considered dime
stable if it is provided with a floor system that is tied to the walls of the structu
that it reacts to loads as a unit. These structures shall be of sufficient weight to
in place or shall be anchored to the ground."
iii. In Section R403.1.4.1, Frost protection, the exceptions shall be deleted and the
following shall be inserted:
Exception: Free standing buildings meeting all of the following conditions sha
required to be protected: |
- |
pdf_text |
| 2 |
2. Any references to the International Plumbing Code or the International Existing Bu
Code throughout the code and listed at Chapter 8 shall be considered a reference to the
appropriate plumbing subcode at N.J.A.C. 5:23-3.15, or rehabilitation subcode at N.J. |
- |
pdf_text |
| 2 |
2. In buildings where limited area sprinkler systems are supplied with
from a common standpipe riser, the supply piping shall be sized for a m
flow of 500 gpm (1892 L/min.) plus the sprinkler demand for the first r |
- |
pdf_text |
| 2 |
2. Accessory garden-type utility sheds and similar structures that are greater th
square feet, but not more than 200 square feet in area, and 10 feet or less in hei
provided the shed is dimensionally stable without the foundation system and d
contain a water, gas, oil or sewer connection. A shed shall be considered dime
stable if it is provided with a floor system that is tied to the walls of the structu
that it reacts to loads as a unit. These structures shall be of sufficient weight to
in place or shall be anchored to the ground." |
- |
pdf_text |
| 2 |
2. Equivalent facilitation, such as a folding shelf attached to the main service c
or space at the side of the service counter."
li. In Section 1111.2.2, Facilities serving Type A and Type B units in a single buil
delete "and Type B" in the title and "or Type B" in the first sentence.
lii. In Section 1111.2.3, Facilities serving Type A and Type B units in multiple bu
delete "and Type B" in the title and "or Type B" in the first sentence.
liii. Sections 1111.4.8, Amusement rides, 1111.4.8.1, Load and unload areas, 111
Wheelchair spaces, ride seats designed for transfer and transfer devices, and 1111.
Minimum number shall be deleted in their entirety.
liv. Sections 1111.4.12, Miniature golf facilities, 1111.4.12.1, Minimum number, |
- |
pdf_text |
| 2 |
2,000 gallons or less," following "(building subcode Use Group R-3/R-4)".
Amended by R.2004 d.67, effective February 17, 2004.
See: 35 N.J.R. 4627(a), 36 N.J.R. 949(b).
In (b), substituted "moving walks in structures of Groups other than R-2, R-3, R-4, or R-5" for "
walks in Use Groups R-3, R-4, or R-2 structures" preceding "in which the elevator devices are wh
within dwelling units".
Amended by R.2004 d.144, effective April 5, 2004.
See: 35 N.J.R. 4944(a), 36 N.J.R. 1753(a).
Added (a)10; in (c), substituted "released" for "approved" following "enforcing agency receives
of the" and added 1.
Administrative correction.
See: 36 N.J.R. 1757(a).
Amended by R.2004 d.260, effective July 6, 2004.
See: 35 N.J.R. 3474(b), 36 N.J.R. 3274(a).
In (j), rewrote 3, deleted former 4 and 5, and recodified former 6 as 4.
Amended by R.2004 d.291, effective August 2, 2004.
See: 36 N.J.R. 1858(a), 36 N.J.R. 3525(b). |
- |
pdf_text |
| 2 |
2. Group A-4, A-5, F-2, R-2, S-2 or U occupancies. |
- |
pdf_text |
| 2 |
2. In buildings where limited area sprinkler systems are supplied with
from a common standpipe riser, the riser shall be sized to satisfy total d |
- |
pdf_text |
| 2 |
2. Public welfare and safety are assured; and |
- |
pdf_text |
| 2 |
2. Plumbing Subcode:
C
ha
pt
er
Section/Title
Respo
nsibilit
y
Plan
Review
Inspection
C
h. |
- |
pdf_text |
| 2 |
2. Buildings constructed in accordance with the provisions of this section and meeting
requirements of (d)1 above shall be classified as commercial farm buildings. For those
provisions not covered by this section, commercial farm buildings shall comply with t
construction code provisions applicable to Group S-2. Commercial farm buildings sha
include, but not be limited to, the following: stall barns, milking parlors, poultry house
arenas, packing houses for agricultural or horticultural commodities, farrowing houses
greenhouses, and buildings used for the storage of agricultural or horticultural product
machinery and farm equipment, or farm materials and supplies that are produced or us
the farm. |
- |
pdf_text |
| 2 |
2
General Regulations
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 2 |
2. A rehabilitation subcode code change proposal shall include the following informat
i. The name, organization, mailing address, telephone number, facsimile number,
mail address of the proponent of the proposed code change;
ii. The primary section of the rehabilitation subcode proposed for change and any
section(s) where corresponding changes are required. Language proposed for delet
be presented in brackets and language proposed for addition shall be underlined; a
iii. A description and supporting statement for the proposed code change. |
- |
pdf_text |
| 2 |
2. The National Electrical Code 2020 may be known and cited as "the electrical subco
i. Codes and standards referenced in the Informational Notes of the electrical subc
(NEC 2020) shall be explanatory material and not adopted as part of the subcode.
application of these codes and standards follow Section 90.5(C) of the electrical su |
- |
pdf_text |
| 2 |
2. Plumbing Subcode:
C
ha
pt
er
Section/Title
Respo
nsibilit
y
Inspection |
- |
pdf_text |
| 2 |
2. Area of 600 square feet (56 m<2>) or less for light framed construction, or
square feet (37 m<2>) or less for other than light-framed construction; and |
- |
pdf_text |
| 2 |
2. Chapter 2, Definitions, shall be deleted, unless referenced for compliance in an opti
appendix. A new definition of "IECC-Commercial Provisions" shall be inserted and d
meeting "the requirements of the ASHRAE Standard 90.1 referenced by Chapter 6 of
commercial provisions of this code." |
- |
pdf_text |
| 2 |
2. Standpipe hose connections for systems required by Section 905.3.2. shall b
permitted to be located only at exits such that all portions of the building floor
not more than 200 feet (60,960 mm) from a hose connection or 200 feet (122
the nearest point of fire department vehicle access."
Also, renumber Items 3 through 6 as 2 through 5. Lastly, in Item #5, "fire code
shall be deleted and "fire protection subcode official" shall be inserted.
xxxii. Insert Section 905.4.3 from Section 915.7.1 of the 1996 BOCA National Bu
Code as follows "905.4.3 Location: At each floor level and not more than 5 feet (1
mm) above the floor, there shall be connected to each standpipe a 2 1/2-inch hose
connection with valves and threads compatible with the connections used by the lo
department."
xxxiii. In Section 905.5.3, Class II system 1-inch hose, "fire code official" shall be
and "fire protection subcode official" shall be inserted. |
- |
pdf_text |
| 2 |
2. The emblem shall be permanently affixed to the left of the main entrance door at a
between four and six feet above the ground and shall be installed and maintained by th
of the building. |
- |
pdf_text |
| 2 |
2. The domestic service shall be capable of supplying the simultaneous domes
demand and the sprinkler demand required to be hydraulically calculated by N
NFPA 13R or NFPA 13D."
xv. In Section 903.4, Sprinkler system supervision and alarms, in exception 2, del
accordance with Section 903.3.8."
xvi. In Section 903.4.1, Monitoring, "fire code official" shall be deleted and "fire
protection subcode official" shall be inserted.
xvii. Section 903.5, "Testing and Maintenance", shall be deleted and the followin
inserted in its place: "903.5 Acceptance tests: All sprinkler systems with the excep
limited area sprinkler systems shall be tested in accordance with NFPA 13 listed in |
- |
pdf_text |
| 2 |
2. The text at section 106.2, entitled "Documents," shall be amended as follow |
- |
pdf_text |
| 2 |
2. Incineration plants; |
- |
pdf_text |
| 2 |
2
General Regulations
Plumbi
ng
Plumbing |
- |
pdf_text |
| 2 |
2. The Department of Health may adopt licensing standards for the physical plant and
environment of health care facilities that supplement this code and the "Guidelines for
and Construction of Health Care Facilities," although these standards may not be in co
with these codes. |
- |
pdf_text |
| 2 |
2. Chapter 2, Definitions, shall be amended as follows:
i. In Section R201.3, Terms defined in other codes, "International Plumbing Code
be deleted and "National Standard Plumbing Code" shall be inserted.
ii. The definitions of "Addition" and "Alteration" shall be deleted.
iii. The definition of "Approved" shall be deleted and the following shall be insert
"Approved refers to approval by the appropriate subcode official or other authority
jurisdiction in accordance with the regulations." |
- |
pdf_text |
| 2 |
2. A horizontal branch drain serving both the lavatory and the batht
shower stall is 2" minimum pipe size. |
- |
pdf_text |
| 2 |
2. The domestic service shall be capable of supplying the simultaneous domes
demand and the sprinkler demand required to be hydraulically calculated by N
NFPA 13R or NFPA 13D."
xiii. At Section 903.4.2, Monitoring, "fire code official" shall be deleted and "fire
protection subcode official" shall be inserted.
xiv. Section 903.5, "Inspection, Testing and Maintenance", shall be deleted and th
following shall be inserted in its place: "903.5 Acceptance tests: All sprinkler syste
the exception of limited area sprinkler systems shall be tested in accordance with
listed in Chapter 35. |
- |
pdf_text |
| 2 |
2. Chapter 1 of the electrical subcode, Article 100, entitled "Definitions," is amended
follows:
i. The definition of the term "approved" is amended to delete the phrase "the auth
having jurisdiction" and substitute in lieu thereof, the phrase "electrical subcode of
Approval shall be in accordance with N.J.A.C. 5:23-3.7."
ii. The definition of "Authority having jurisdiction" is replaced with "Unless other
specifically noted, the authority having jurisdiction for the Electrical Subcode shal
Electrical Subcode Official."
iii. The definition of the term "building" is deleted and in lieu thereof, substitute t
definition of the term "building" found in N.J.A.C. 5:23-1.4". |
- |
pdf_text |
| 2 |
2. The National Electrical Code 2023 may be known and cited as "the electrical subco
i. Codes and standards referenced in the Informational Notes of the electrical subc
(NEC 2020) shall be explanatory material and not adopted as part of the subcode.
application of these codes and standards follow Section 90.5(C) of the electrical su |
- |
pdf_text |
| 2 |
2. Group A-4, A-5, F-2, R-2, S-2 or U occupancies. |
- |
pdf_text |
| 2 |
2>
P2904.1
Plumbing/Fire
Plumbing
P2904.1.1-
P2904.2.2
Fire
Fire
P2904.2.3
Plumbing
Plumbing
P2904.2.4-
P2904.2.6
Fire
Fire
P2904.3-P2904.3.3
Plumbing
Plumbing
P2904.3.4
Fire/Plumbing
Plumbing
P2904.4
Fire/Plumbing
Fire
P2904.5-P2904.6
Fire/Plumbing
Plumbing
P2904.7
Fire/Plumbing
Fire
P2904.8.1 #1
Fire
Fire
P2904.8.1 #2
Fire
Fire
P2904.8.1 #3
Fire
Fire
P2904.8.1 #4 -
Fire/Plumbing
Plumbing
#6
P2904.8.1 #7
Plumbing
Plumbing
and #8
P2904.8.2 #1
Fire
Fire
P2904.8.2 #2-#4
Fire/Plumbing
Fire
App
x.
Tiny Houses
Building/Fire (except
Building (except that
BB
that BB106, responsibility
BB106, responsibility
shall be as applicable)
shall be as applicable)
App
x.
Patio Covers
Building
Building
BF |
- |
pdf_text |
| 2 |
2. In buildings where limited area sprinkler systems are supplied with wat
common standpipe riser, the supply piping shall be sized for a minimum fl |
- |
pdf_text |
| 2 |
2. Such proposal shall be on a form provided by the model code organization where o
available. If none is available, such proposal shall state the name and address of the pa
official proposing the model code change, the company, agency, or political subdivisi
represented, if applicable, the text of the amendment suggested and an explanation of t
amendment together with any technical justification deemed necessary by the propone |
- |
pdf_text |
| 2 |
2. Electrical materials/supplies:
i. As stated in the National Electrical Code (sections 90.7, 110.2, and 110.3 and A |
- |
pdf_text |
| 2 |
2. Chapter 1 of the electrical subcode, Article 100, entitled "Definitions," is amended
follows:
i. The definition of the term "approved" is amended to delete the phrase "the auth
having jurisdiction" and substitute in lieu thereof, the phrase "electrical subcode of
Approval shall be in accordance with N.J.A.C. 5:23-3.7."
ii. The definition of "Authority having jurisdiction" is replaced with "Unless other
specifically noted, the authority having jurisdiction for the Electrical Subcode shal
Electrical Subcode Official."
iii. The definition of the term "building" is deleted and in lieu thereof, substitute t
definition of the term "building" found in N.J.A.C. 5:23-1.4".
iv. The definition of the term "qualified person" shall be amended to add "or one
permitted to undertake work pursuant to the relevant licensing law, N.J.S.A. 45:5A
seq." after the word "involved." |
- |
pdf_text |
| 2 |
2. Notices and orders: Such official(s) shall issue all necessary notices or orders to re
illegal or unsafe conditions; to require the necessary safeguards during construction; a
insure compliance with all requirements for the safety, health and general welfare of t
public. |
- |
pdf_text |
| 2 (cont. 2) |
"Building Official" and "Change of Occupancy" shall be del |
- |
pdf_text |
| 2 (cont. 2) |
n methods, Item 4 shall be deleted.
x. In Section 1810.3.10.4, Seismic reinforcement, "Section 104.11" shall be delete
"the administrative provisions of the Uniform Construction Code (N.J.A.C. 5:23)"
inserted. |
- |
pdf_text |
| 2.1 |
2.1 In Section 201.3, Terms defined in other codes, "International Plum
Code" shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" s
inserted. |
- |
pdf_text |
| 2.1 |
2.1 In Section 201.3, Terms defined in other codes, "International Plu
Code" shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" s
inserted. |
- |
pdf_text |
| 2.1 |
2.1 At Section 106.2.4, entitled "National Fire Alarm and Signaling Code,
"NFPA 72-2016" and insert "the edition of NFPA 72 adopted by reference
subcode;" |
- |
pdf_text |
| 2.1 |
2.1 In section 106.2.4, entitled "National Fire Alarm Code," delete "NFPA |
- |
pdf_text |
| 2.1 |
2.1 At Section 201.3, Terms defined in other codes, "International Plumbi
shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inse |
- |
pdf_text |
| 2.1 |
2.1 In small buildings as defined in Section 1104.4.1; |
- |
pdf_text |
| 2.14 |
2.14" shall be inserted.
v. At Section R407.3, Structural requirements, in the exception, delete the phrase
Seismic Design Categories A, B, and C" at the beginning of the sentence. |
- |
pdf_text |
| 2.14 |
2.14" shall be inserted.
viii. Sections R405, Foundation Drainage, with the exception of Table R405.1, w
be renumbered as "Table R406.1", and R406, Foundation Waterproofing and
Dampproofing, shall be deleted and the text of Section 1805, Dampproofing and
Waterproofing from the building subcode shall be inserted as follows:
"R406.1 General. Walls or portions thereof that retain earth and enclose interi
spaces and floors below grade shall be waterproofed and dampproofed in accor
with this section, with the exception of those spaces containing groups other th
residential and institutional where such omission is not detrimental to the build
occupancy. Ventilation for crawl spaces shall comply with Section R408.
R406.1.1 Story above grade plane. Where a basement is considered a story ab
grade and the finished ground level adjacent to the basement wall is below the
basement floor elevation for 25 percent or more of the perimeter, the floor and
shall be dampproofed in accordance with Section R406.2 and a foundation drai
be installed in accordance with Section R406.4.2. The foundation drain shall b |
- |
pdf_text |
| 2.2 |
2.2 In Section 202, Definitions: |
- |
pdf_text |
| 2.2 |
2.2 At Section 202, Definitions: |
- |
pdf_text |
| 2.2 |
2.2 In section 106.2.6, entitled "Power Assist and Low Energy Power Ope
Doors," delete "ANSI/BHMA A156.19-2013" and insert "the edition of
ANSI/BHMA A156.19 adopted by reference in this subcode;" |
- |
pdf_text |
| 2.2 |
2.2 At Section 202, Definitions: |
- |
pdf_text |
| 2.2 |
2.2 In Section 202, Definitions: |
- |
pdf_text |
| 2.2 |
2.2 In individual tenancies of less than 10,000 square feet in buildings of 1
square feet or more; |
- |
pdf_text |
| 2.2.1 |
2.2.1 The definition of "alteration" shall be deleted. |
- |
pdf_text |
| 2.2.1 |
2.2.1 The definition of "alteration" shall be deleted. |
- |
pdf_text |
| 2.2.2 |
2.2.2 The definition of "code official" shall be deleted and the follo
shall be inserted:
"Construction Official. A qualified person appointed by the
appointing authority or the commissioner pursuant to the act
regulations to enforce and administer the regulations within the ju
of the enforcing agency." |
- |
pdf_text |
| 2.2.2 |
2.2.2 The definition of "code official" shall be deleted and the followin
be inserted:
"Construction Official. A qualified person appointed by the
appointing authority or the commissioner pursuant to the act and the re
to enforce and administer the regulations within the jurisdiction of the
agency." |
- |
pdf_text |
| 2.2.2 |
2.2.2 The definition of "code official" shall be deleted and the follo
shall be inserted: "Construction Official. A qualified person appoint
the municipal appointing authority or the commissioner pursuant to
and the regulations to enforce and administer the regulations within
jurisdiction of the enforcing agency." |
- |
pdf_text |
| 2.2.3 |
2.2.3 The definition of "existing pool or spa" shall be deleted. |
- |
pdf_text |
| 2.2.3 |
2.2.3 The definition of "existing pool or spa" shall be deleted. |
- |
pdf_text |
| 2.2.4 |
2.2.4 The definition of "owner" shall be deleted and the following
inserted: "Owner. The owner or owners in fee of the property of a l
estate therein, a mortgagee or vendee in possession, an assignee of r
receiver, executor, trustee, lessee or any other person, firm or corpo |
- |
pdf_text |
| 2.2.4 |
2.2.4 The definition of "owner" shall be deleted and the following shal
inserted:
"Owner. The owner or owners in fee of the property of a lesser est
therein, a mortgagee or vendee in possession, an assignee of rents, r
executor, trustee, lessee or any other person, firm or corporation, di
indirectly in control of a building, structure or real property and sha
include any subdivision thereof of the State." |
- |
pdf_text |
| 2.2.4 |
2.2.4 The definition of "owner" shall be deleted and the following s
inserted: "Owner. The owner or owners in fee of the property of a l
estate therein, a mortgagee or vendee in possession, an assignee of r
receiver, executor, trustee, lessee or any other person, firm or corpo
directly or indirectly in control of a building, structure or real prope
shall include any subdivision thereof of the State." |
- |
pdf_text |
| 2.2.5 |
2.2.5 The definitions of "peer review," "permit," and "repair" shall
deleted. |
- |
pdf_text |
| 2.2.5 |
2.2.5 The definitions of "peer review," "permit," and "repair" shall be |
- |
pdf_text |
| 2.2.5 |
2.2.5 The definitions of "permit" and "repair" shall be deleted. |
- |
pdf_text |
| 2.2.5 |
2.2.5 The definitions of "permit" and "repair" shall be deleted. |
- |
pdf_text |
| 2.3 |
2.3 In section 106.2.7, entitled "Power Operated Pedestrian Doors," delete
"ANSI/BHMA A156.10-2011" and insert "the edition of ANSI/BHMA A1
adopted by reference in this subcode;" |
- |
pdf_text |
| 2.3 |
2.3 To serve floors or mezzanines of less than 3,000 square feet; or |
- |
pdf_text |
| 2.4 |
2.4 In section 106.2.8, entitled "Safety Code for Elevators and escalators,"
"ASME/ANSI A17.1-2013/CSA B44-16" and insert "the edition of ASME/
A17.1/CSA B44 adopted by reference in this subcode;" |
- |
pdf_text |
| 2.4 |
2.4 In Group A-3, places of religious worship, or Group E occupancies of
size."
xlix. At Section 1110.11, Lifts, items 4, 6, and 10 shall be deleted.
l. At Section 1110.16.2, Sales and service counters and windows, insert the follow
exceptions: |
- |
pdf_text |
| 2.4 |
2.4 In Group A-3, places of religious worship, or Group E occupancies of
size."
l. In Section 1110.9, Lifts, Items #4, #6, and #10 shall be deleted.
li. In Section 1110.13.2, Sales and service counters and windows, insert the follo
exceptions:
"Exceptions: |
- |
pdf_text |
| 2.5 |
2.5 In section 106.2.9, entitled "Safety Standard for Platform Lifts and Sta
Chairlifts," delete "ASME/ANSI A18.1-2014" and insert "ASME/ANSI A
adopted by reference in this subcode." |
- |
pdf_text |
| 20 |
20
Heaters
Ch.
Hydronic
Plumbing
Plumbing |
- |
pdf_text |
| 20 |
20. Appendix M, entitled "Impact of Water Temperature on the Potential for Scalding
Legionella Growth" shall be deleted. |
- |
pdf_text |
| 20 |
20. Chapter 27, Electrical, shall be deleted except Section 2702, Emergency and stand
power systems, which shall be amended as follows:
i. In Section 2702.2.4, Emergency voice/alarm communication systems, the text s
deleted, and the following language from Section 2702.2.4 of the 2018/IBC shall b
inserted: "Emergency power shall be provided for emergency voice/alarm commu
systems as required in Section 907.5.2.2.5. The system shall be capable of powerin
required load for a duration of not less than 24 hours, as required in NFPA 72." |
- |
pdf_text |
| 20 |
20
Boilers/Water
Plumbing
Plumbing
Heaters
Ch.
Hydronic
Plumbing
Plumbing |
- |
pdf_text |
| 20 |
20. At Chapters 25 through 28, the subsections shall be deleted and "The applicable
requirements under the scope of this subcode shall be regulated by the plumbing subc
N.J.A.C. 5:23-3.15" shall be inserted at each section title. |
- |
pdf_text |
| 20 |
20. Chapters 25 through 28 shall be deleted in their entirety and "Plumbing requireme
under the scope of this subcode shall be regulated by the plumbing subcode, N.J.A.C. |
- |
pdf_text |
| 20 |
20. Amend section 1102.3.1, entitled "Location," as follows: |
- |
pdf_text |
| 20 |
20
Aluminum
Building
Building
Ch. |
- |
pdf_text |
| 20 |
20. Chapters 28, Mechanical Systems, and 29, Plumbing Systems, shall be deleted in
entirety. |
- |
pdf_text |
| 20.1 |
20.1 In the Exception, delete the word "unfinished" in two places. |
- |
pdf_text |
| 200.1-250.50 |
200.1-250.50
Electrical
Electrical |
- |
pdf_text |
| 200.1-250.50 |
200.1-250.50A(2)
Electrical
Electrical |
- |
pdf_text |
| 2016 |
2016/CSA B44-16" deleted and "ASME A17.1-2019/CSA B44-19" shall be insert
place; and
v. In Section 620.91, Emergency and Standby Power Systems, Informational Note
shall have "ASME A17.1-2016/CSA B44-16" deleted and "ASME A17.1-2019/CS |
- |
pdf_text |
| 2016 |
2016" and insert "the edition of NFPA 72 adopted by reference in this subc |
- |
pdf_text |
| 2021 |
2021, c. 464 (N.J.S.A. 52:27D-141.18, et seq.), whichever is more restrictive" at th
the sentence.
vii. At Section 7.11.4, Service Sinks and Mop Receptors, b. is amended to delete t
following after "surface," "at least one foot in front of the sink or receptor, at least
on each side, and up to a point one foot above the faucet height," and insert, "refer
International Building Code, Section 1210.2.2."
viii. In Section 7.18.2, Approval, "to the Authority Having Jurisdiction" shall be d
ix. At Section 7.21.2, Occupant Load, b. "building code" shall be deleted and "bui
subcode" shall be inserted.
x. At Section 7.21.9, Family and Assisted-Use Toilet Rooms, "applicable building
shall be deleted and "building subcode" shall be inserted. |
- |
pdf_text |
| 2021 |
2021, c. 464 (N.J.S.A. 52:27D-141.18, et seq.), whichever is more restrictive" at th
the sentence.
iv. Section 7.5.3, Surrounding Surfaces, is amended to delete the following after "
"extending not less than four feet above the floor. One foot to each side of the urin
one foot in front of the lip of the urinal. See Figure 7.5.3.," and insert, "Refer to th
International Building Code, Sections 1210.2.1 and 1210.2.2." This section is ame
delete Figure 7.5.3, "Protecting Surrounding Surfaces of Urinals."
v. Section 7.6.2, Water conservation, shall be amended to add "or as required by P |
- |
pdf_text |
| 2021 |
2021, c. 464 (N.J.S.A. 52:27D-141.18, et seq.), whichever is more restrictive" at th
the sentence.
vi. Section 7.10.2, Water conservation, shall be amended to add "or as required by |
- |
pdf_text |
| 2021 |
2021, c. 464 (N.J.S.A. 52:27D-141.18, et seq.), whichever is more restrictive" at th
the sentence.
iii. Section 7.5.2, Water conservation, shall be amended to add "or as required by |
- |
pdf_text |
| 2024 |
2024 IECC Stretch Code
As applicable
As applicable
R
H
Operational Carbon Rating and
As applicable
As applicable
Energy Reporting
RI
On-Site Renewable Energy
As applicable
As applicable
RJ
Demand Responsive Controls
As applicable
As applicable
R
K
Electric-Ready Residential
As applicable
As applicable |
- |
pdf_text |
| 2024 |
2024 IECC
As applicable
As applicable
RG
Stretch Code
App
x.
Operational
As applicable
As applicable
RH
Carbon Rating and
Energy Reporting
App
x.
On-Site
As applicable
As applicable
RI
Renewable Energy
App
x.
Demand
As applicable
As applicable
RJ
Responsive
Controls
App
x.
Electric-Ready
As applicable
As applicable
RK
Residential
Building
Provisions
App
x.
Renewable
As applicable
As applicable
RL
Energy
Infrastructure
Res
All-Electric
As applicable
As applicable |
- |
pdf_text |
| 2025 |
2025," shall be inserted at the beginning of the sentence, and "regardless of the gra
period set forth pursuant to N.J.A.C. 5:23-1.6" shall be inserted at the end of the se
Additionally, the text of the exception shall be deleted, and "A newly constructed
townhouse shall not be subject to this section if an application for a construction p
an application for development has been submitted to a State, county, or municipal
prior to July 10, 2024" shall be inserted in its place.
xxv. Section R313.2, One- and two-family dwellings automatic sprinkler systems,
deleted. Section R313.2.1 shall be retained.
xxvi. Section R314.2.2, Alterations, repairs and additions, shall be deleted.
xxvii. In Section R314.6, Power source, both exceptions shall be deleted.
xxviii. New Section R314.7.5 shall be inserted as follows: "R314.7.5, Monitoring.
system shall be monitored by an approved supervising station and shall be maintai
accordance with NFPA 72."
xxix. In Section R315.2, Where required, "and R315.2.2" shall be deleted. Also, S
R315.2.2, Alterations, repairs and additions, shall be deleted. Lastly, exception 2 o
R315.6, Power source, shall be deleted.
xxx. In Section R319.1, Address Identification, the fourth, fifth, and ninth sentenc
be deleted. Additionally, in the seventh sentence, "fire code official" shall be delet
"fire protection subcode official" shall be inserted.
xxxi. Section R320, Accessibility, shall be deleted. |
- |
pdf_text |
| 2025 |
2025," shall be inserted at the beginning of the sentence, and "regardless of the gra
period set forth pursuant to N.J.A.C. 5:23-1.6" shall be inserted at the end of the se
Additionally, the text of the exception shall be deleted, and "A newly constructed
townhouse shall not be subject to this section if an application for a construction p
an application for development has been submitted to a State, county, or municipal
prior to July 10, 2024" shall be inserted in its place.
xxi. Section R309.2, One- and two-family dwellings automatic sprinkler systems,
deleted. Section R309.2.1 shall be retained.
xxii. Section R310.2.2, Alterations, repairs and additions, shall be deleted.
xxiii. At Section R310.6, Power source, both exceptions shall be deleted.
xxiv. At Section R310.7, "R310.7.4" shall be deleted and "R310.7.5" shall be inse
its place. |
- |
pdf_text |
| 21 |
21. Appendix N, entitled "Non-Sewered Sanitation Systems" shall be deleted. |
- |
pdf_text |
| 21 |
21, National Standard Plumbing Code" shall be inserted. In addition, at the bottom
ICC table, "**NSPC-21 is non-ICC and is published by the International Associati
Plumbing and Mechanical Officials" shall be inserted. |
- |
pdf_text |
| 21 |
21. In section 1102.15.2, Bed Frames, "with a minimum of six and one-half in
clear from the floor to the lowest level of the bed frame" shall be inserted at th
the sentence. |
- |
pdf_text |
| 21 |
21. Chapter 30, Elevators and Conveyor Systems, shall be amended as follows:
i. In Section 3001.1, Scope, "and, where applicable, N.J.A.C. 5:23-12 shall" shall
inserted after "chapter." In addition, "governs" shall be deleted and "govern" shall
inserted.
ii. Table 3001.3, Elevators and conveying systems and components, is amended a
follows: Under the subheading "Type" delete "Elevators, escalators, dumbwaiters,
walks, material lifts" and substitute with "Elevator devices as defined in N.J.A.C.
Under the subheading "Standard" delete "ASME A17.1/CSA B44" and substitute
"ASME A17.1/CSA B44 with the exception of Sections 1.1.3 and 1.2, Sections 5.
and 5.11, and 5.12, Sections 7.4 through 7.7, and Sections 7.9 and 7.10"; Insert ne
statements: Under the subheading "Type" insert "Marine and Mine Elevators, Win
Turbine Tower Elevators, Outside Emergency Elevators, Material Lifts Without A
Transfer Devices, Electric and Hydraulic Material Lifts Without Automatic Transf
Devices, Automatic Transfer Devices, Electric and Hydraulic Material Lifts With
Automatic Transfer Devices." and under the subheading "Standard," insert "ASM
A17.1/CSA B44 Sections 5.8 and 5.9, 5.11, 5.12, Sections 7.4 through 7.7, and Se |
- |
pdf_text |
| 21 |
21
Piping, except
M2101.6
M2101.6
Building/Plumbing
Building
Ch. |
- |
pdf_text |
| 21 |
21. Chapters 28, Mechanical Systems, and 29, Plumbing, shall be deleted in their enti |
- |
pdf_text |
| 21 |
21. Chapter 29, Water Supply and Distribution, shall be deleted except P2904, Dwelli
fire sprinkler systems. The deleted sections shall have "Plumbing requirements under t
of this subcode shall be regulated by the plumbing subcode, N.J.A.C. 5:23-3.15." inser
i. Section P2904 shall be amended as follows:
(1) In Section P2904.1, General, the last sentence shall be deleted and "A back
flow preventer shall be required to separate a stand-alone sprinkler system fro
water distribution system in accordance with the plumbing subcode (N.J.A.C. |
- |
pdf_text |
| 21 |
21
Piping, except
M2101.6
M2101.6
Building/Plumbing
Building
Ch.
Special Piping |
- |
pdf_text |
| 21 |
21. Chapter 29, Water Supply and Distribution, shall be deleted except P2904, Dwelli
fire sprinkler systems. The deleted sections shall have "Plumbing requirements under t
of this subcode shall be regulated by the plumbing subcode, N.J.A.C. 5:23-3.15." inser
i. Section P2904 shall be amended as follows: |
- |
pdf_text |
| 2101-2110 |
2101-2110
Building
Building |
- |
pdf_text |
| 2101-2110 |
2101-2110
Building
Building |
- |
pdf_text |
| 2111-2113 |
2111-2113
Building/Fire
Building |
- |
pdf_text |
| 2111-2113 |
2111-2113
Building/Fire
Building |
- |
pdf_text |
| 2114 |
2114
Building
Building
Ch. |
- |
pdf_text |
| 2114 |
2114
Building
Building
C
h.
Steel
Building
Building |
- |
pdf_text |
| 22 |
22
and Storage |
- |
pdf_text |
| 22 |
22. Appendix O, entitled "Indoor Horticultural Facilities" shall be deleted.
(c) A newly installed automatic lawn sprinkler system, where such systems are not prohib
local ordinance, shall be equipped with an automatic rain sensor device or switch that will |
- |
pdf_text |
| 22 |
22
Special Piping
and Storage
Systems
M2201
Fire
Fire
M2201.3
Building/Fire/Plumbing
Building
M2202-M2204
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 22 |
22. Chapter 31, Special Construction, shall be amended as follows:
i. New Section 3102.3.2, which shall be the text of Section 3104.6 of the 1996 B
National Building Code, shall be inserted as follows: "Certification: An affidavit o
affirmation shall be submitted to the code official and a copy retained on the premi
which the tent or air-supported structure is located. The affidavit or affirmation sh
to the following information relative to the flame-resistance of the fabric: |
- |
pdf_text |
| 22 |
22. At Chapters 30 through 33, the subsections shall be deleted and "The applicable
requirements under the scope of this subcode shall be regulated by the plumbing subc
N.J.A.C. 5:23-3.15." shall be inserted at each section title. |
- |
pdf_text |
| 22 |
22. Chapter 30, Elevators and Conveyor Systems, shall be amended as follows:
i. In Section 3001.1, Scope, "and, where applicable, N.J.A.C. 5:23-12 shall" shall
inserted after "chapter." In addition, "governs" shall be deleted and "govern" shall
inserted.
ii. Section 3001.2, Emergency elevator communication systems for the deaf, hard
hearing, and speech impaired, shall be deleted.
iii. Table 3001.3, Elevators and conveying systems and components, is amended a
follows: Under the subheading "Type" delete "Elevators, escalators, dumbwaiters,
walks, material lifts" and substitute with "Elevator devices as defined in N.J.A.C.
Under the subheading "Standard" delete "ASME A17.1/CSA B44" and substitute
"ASME A17.1/CSA B44 with the exception of Sections 1.1.3 and 1.2, Sections 5.
and 5.11, and 5.12, Sections 7.4 through 7.7, and Sections 7.9 and 7.10"; Insert ne
statements: Under the subheading "Type" insert "Marine and Mine Elevators, Win
Turbine Tower Elevators, Outside Emergency Elevators, Material Lifts Without A |
- |
pdf_text |
| 22 |
22
Steel
Building
Building
Ch. |
- |
pdf_text |
| 22 |
22. Chapters 30 through 33 shall be deleted in their entirety and "Plumbing requireme
under the scope of this subcode shall be regulated by the plumbing subcode, N.J.A.C. |
- |
pdf_text |
| 22 |
22. Amend section 1103.3.1, entitled "Location," as follows: Insert "1." before
existing exception and delete "unfinished" in two places. Additionally, insert
"Exception 2. An accessible route is not required to exterior decks, patios, or b
that have impervious or improved surfaces that are not more than four (4) inch
the finished floor level of the adjacent interior space of the dwelling unit." |
- |
pdf_text |
| 23 |
23. Chapter 32, Encroachments into the Public Right of Way, shall be amended as fo
i. In Section 3202.1.2, Vaults and other enclosed spaces, "applicable governing a
shall be deleted and "Uniform Construction Code (N.J.A.C. 5:23)" shall be inserte |
- |
pdf_text |
| 23 |
23
Solar Systems
M2301.2.1-
M2301.2.2
Building
Building
M2301.2.3-
M2301.5
Plumbing
Plumbing
M2301.6
Building
Building
M2301.7
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 23 |
23
C
h.
Glass and Glazing
Building
Building |
- |
pdf_text |
| 23 |
23
Wood
Building
Building
Ch. |
- |
pdf_text |
| 23 |
23. Section 1103.10, Laundry equipment, shall be deleted in its entirety. |
- |
pdf_text |
| 23 |
23. Chapter 31, Special Construction, shall be amended as follows:
i. New Section 3102.3.2, which shall be the text of Section 3104.6 of the 1996 BO
National Building Code, shall be inserted as follows: "Certification: An affidavit o
affirmation shall be submitted to the code official and a copy retained on the premi
which the tent or air-supported structure is located. The affidavit or affirmation sh
to the following information relative to the flame-resistance of the fabric: |
- |
pdf_text |
| 23 |
23. At Chapters 34 through 43, the subsections shall be deleted and "The applicable
requirements under the scope of this subcode shall be regulated by the electrical subco
N.J.A.C. 5:23-3.16." shall be inserted at each section title. |
- |
pdf_text |
| 23 |
23. Chapters 34 through 43 shall be deleted in their entirety and "Electrical requireme
under the scope of this subcode shall be regulated by the electrical subcode, N.J.A.C. |
- |
pdf_text |
| 23 |
23
M2301.2.1-M2301.2.2
Building
Building
M2301.2.3-M2301.5
Plumbing
Plumbing
M2301.6
Building
Building
M2301.7-M2301.7.2
Plumbing
Plumbing
Ch.
Fuel Gas |
- |
pdf_text |
| 23-1 |
23-1 through 70-23-13 as the electrical subcode for New Jersey.
i. Copies of this code may be obtained from the sponsors at NFPA, One Batterym
Park, Quincy, Massachusetts 02169. |
- |
pdf_text |
| 24 |
24
Glass and Glazing
Building
Building
Ch. |
- |
pdf_text |
| 24 |
24. Section 1103.11.2.5.2, entitled "Shower," shall be amended as follows: |
- |
pdf_text |
| 24 |
24. Chapter 32, Encroachments into the Public Right of Way, shall be amended as fol
i. In Section 3202.1.2, Vaults and other enclosed spaces, "applicable governing au
shall be deleted and "Uniform Construction Code (N.J.A.C. 5:23)" shall be inserte
ii. In Section 3202.3.4, Pedestrian walkways, "applicable governing authority" sha
deleted and "the construction official" shall be inserted.
iii. In Section 3202.4, Temporary encroachments, "applicable governing authority
be deleted and "municipality" shall be inserted. |
- |
pdf_text |
| 24 |
24. Chapter 33, Safeguards During Construction, shall be amended as follows:
i. Sections 3303.1, Construction documents; 3303.2, Pedestrian protection; 3303.
Vacant lot; 3303.5, Water accumulation; and 3303.6, Utility connections, shall be
in their entirety.
ii. Section 3305, Sanitary, shall be deleted in its entirety.
iii. Section 3307.1, Protection required, shall be deleted in its entirety and the foll
shall be inserted: "Protection of adjoining properties shall be in accordance with N |
- |
pdf_text |
| 24 |
24." shall be inserted after the first sentence.
xvii. At Section R306.3, Coastal high-hazard areas (including V Zones and Coast
Zones, where designated), "Sections R306.3.1 through R306.3.10" shall be deleted
"ASCE 24" shall be inserted in its place. Additionally, the text of Sections R306.3.
through R306.3.10, shall be deleted, and "See ASCE 24" shall be inserted after eac
xviii. Section 307, Storm Shelters, shall be deleted.
xix. At Section R308.1, Address Identification, the fourth, fifth, and ninth sentenc
be deleted. Additionally, in the seventh sentence, "fire code official" shall be delet
"fire protection subcode official" shall be inserted.
xx. Section R309.1, Townhouse automatic fire sprinkler systems, "As of February |
- |
pdf_text |
| 24 |
24
C
h.
Gypsum Board, Gypsum
Building
Building |
- |
pdf_text |
| 24 |
24
Fuel Gas
G2404.2-G2404.3
Fire
Fire
G2404.4-G2404.6
Building
Building
G2404.7
See R306
See R306
G2404.8-G2404.9
Building
Building
G2404.10-
G2404.11
Plumbing
Plumbing
G2405
Building
Building
G2406
Plumbing
Plumbing
G2407-G2409
Fire
Fire
G2410
Electrical
Electrical
G2411
Plumbing/Electrical
Plumbing-except when
bonded to electrical
service equipment, then
Electrical
G2412-G2424
Plumbing
Plumbing |
- |
pdf_text |
| 24 |
24. The Appendices shall be amended as follows:
i. Appendix AA, Sizing and Capacities of Gas Piping; Appendix AB, Sizing of V
Systems Serving Appliances Equipped with Draft Hoods, Category I Appliances, a
Appliances Listed for Use with Type B Vents; and Appendix AC, Exit Terminals
Mechanical Draft and Direct-Vent Venting Systems are informative and are not pa
one- and two-family dwelling subcode.
ii. Appendix AD, Recommended Procedure for Safety Inspection of an Existing A
Installation; Appendix AE, Manufactured Housing Used as Dwellings; Appendix
Radon Control Methods; and Appendix AG, Piping Standards for Various Applica
are deleted in their entirety.
iii. Appendix AH, Patio Covers, and Appendix AK, Sound Transmission, shall be
as part of this subcode. |
- |
pdf_text |
| 24 |
24. Chapter 44, Referenced Standards, shall be amended as follows:
i. At the heading ICC, amend the following titles: |
- |
pdf_text |
| 24 |
24
G2404.2-G2404.3
Fire
Fire
G2404.4-2404.9
Building
Building
G2404.10-G2404.11
Plumbing
Plumbing
G2405
Building
Building
G2406
Plumbing
Plumbing
G2407-G2409
Fire
Fire
G2410
Electrical
Electrical
G2411
Plumbing/Electrical
Plumbing-except when
bonded to electrical
service equipment, then
Electrical |
- |
pdf_text |
| 24.1 |
24.1. In the first line, after the word "Exception," insert the number "1." |
- |
pdf_text |
| 24.2 |
24.2. Add the following text at the end of the Exception: "2. The threshold
shower compartment may be adaptable provided the shower threshold can
accessible with minimal expense and effort." |
- |
pdf_text |
| 25 |
25 REM
source 100 REM
source
sealed source
sealed source
j. Maximum dosage allowed in any single whole-body short-term (1 hour or
less) exposure.
ii. In Section 307.6, High-hazard Group H-4, "Radioactive material" shall be inser
the list of materials.
iii. At Section 308.2, Institutional Group I-1, in the list, the word "treatment" shall
inserted following "drug" in the first item; "Assisted living facilities" and "Congre |
- |
pdf_text |
| 25 |
25. The Appendices and Resources shall be amended as follows:
i. Adopted as part of this subcode: BB, Tiny Houses; BF, Patio Covers; BG, Soun
Transmission; BI, Light Straw-Clay Construction; BJ, Strawbale Construction; BK
Construction (Monolithic Adobe); BL, Hemp-Lime (Hempcrete) Construction; B
Printed Building Construction; and BN, Extended Plate Wall Construction.
ii. Informative and not part of this subcode: CA, Sizing and Capacities of Gas Pipi
CB, Sizing of Venting Systems Serving Appliances Equipped with Draft Hoods, C
I Appliances and Appliances Listed for Use with Type B Vents.
iii. Optional at the discretion of the permit applicant: NB, Solar-Ready Provisions
Detached One- And Two-Family Dwellings and Townhouses; NC, Zero Net Ener
Residential Building Provisions; ND, Electric Energy Storage Provisions; NE, Ele |
- |
pdf_text |
| 25 |
25. Chapter 33, Safeguards During Construction, shall be amended as follows:
i. Sections 3303.1, Construction documents; 3303.2, Pedestrian protection; 3303.4
lot; 3303.5, Water accumulation; and 3303.6, Utility connections, shall be deleted
entirety.
ii. Section 3305, Sanitary, shall be deleted in its entirety.
iii. Section 3307.1, Protection required, shall be deleted in its entirety and the foll
shall be inserted: "Protection of adjoining properties shall be in accordance with N |
- |
pdf_text |
| 25 |
25
Panel Products, and
Plaster
C
h.
Plastic |
- |
pdf_text |
| 25 |
25 percent of the building perimeter fronting on a street or other unocc
space. The unoccupied space shall be on the same lot or dedicated for p
use, shall be not less than 30 feet in width, and shall have access from a
by a posted fire lane that is not less than 18 feet in width.
R300.4 Buildings of VA construction. Buildings of VA, protected wood fr
construction, as that term is defined in Section 602 of the building subcode
not more than three stories, not more than 40 feet in height, and not more t |
- |
pdf_text |
| 25 |
25
Gypsum Board, Gypsum
Building
Building
Panel Products, and |
- |
pdf_text |
| 25 |
25 REM
source 100 REM
source
sealed source
sealed source
<j> Maximum dosage allowed in any single whole-body short-term (1 hour
exposure.
ii. In Section 307.6, High-hazard Group H-4, "Radioactive material" shall be inser
the list of materials.
iii. Section 308.1, Institutional Group I, shall be amended as follows: In the fourth
fifth line, "who are or are not capable of self-preservation without physical assista
shall be deleted and "where evacuation is slow or impractical" shall be inserted in i
iv. In Section 308.2, Institutional Group I-1, in the fourth line following "environ
comma shall be inserted and "and" shall be deleted. In the fifth line, following the
"care" the following shall be inserted: "and are capable of slow evacuation." Addit
in the list, the word "treatment" shall be inserted following "drug" in the first item;
"Assisted living facilities" and "Congregate care facilities" shall be deleted; and th
"Boarding houses" and "Residential health care facilities" shall be inserted.
v. In Section 308.3, Group I-2, "who are incapable of self-preservation" shall be d
and "where evacuation is impractical" shall be inserted. Additionally, "Assisted liv
facilities" shall be added to the list and "Foster care facilities" shall be deleted.
vi. In Section 308.3.1.1, Condition 1, at the end of the sentence, "and foster care f
shall be deleted.
vii. In Section 308.3.2, Five or fewer persons receiving medical care, in the sixth
seventh line delete "903.3.1. |
- |
pdf_text |
| 25 |
25. Chapter 35, Referenced Standards, shall be amended as follows:
i. At the heading "ASHRAE," amend the following title:
(1) At "90.1-2022", insert, "as adopted at N.J.A.C. 5:23-3.18, energy subcode
"Buildings".
ii. Under the heading ASME, add the following note:
Note: Those sections of ANSI A17.1/CSA B44 that are noted as applicable in
are not included as part of the referenced document.
iii. Under the heading "ICC," amend the following titles:
(1) At "IECC-24", insert ", as adopted at N.J.A.C. 5:23-3.18, energy subcode"
"Code".
(2) At "IFGC-24", insert ", as adopted at N.J.A.C. 5:23-3.22, fuel gas subcode
"Code". |
- |
pdf_text |
| 25 |
25 REM unsealed |
- |
pdf_text |
| 25 |
25. In section 1103.12.3.1, entitled "Clear Floor Space," delete Exception 1. in
entirety and insert in its place: "1. the cabinetry can be removed or replaced as |
- |
pdf_text |
| 25 (cont. 2) |
3 or with Section P2904 of the International Residenti
and insert "903.3.1.1". |
- |
pdf_text |
| 250 |
250 gpm (945 L/min.) for each additional riser, and the total shall not b
required to exceed 1,250 gpm (4731 L/min.). |
- |
pdf_text |
| 250.104 |
250.104(A)(1)
Electrical
Electrical
(except gas water
heater
replacements)
Plumbing (gas
water heater
replacements onl |
- |
pdf_text |
| 250.104 |
250.104(A)(1)
Electrical
Electrical
(except gas wate
heater
replacements)
Plumbing (gas
water heater
replacements onl |
- |
pdf_text |
| 250.104 |
250.104(A)(2)-250.194
Electrical
Electrical |
- |
pdf_text |
| 250.104 |
250.104(A)(2)-250.194
Electrical
Electrical
Ch. 3
Wiring Methods and Materials |
- |
pdf_text |
| 250.52 |
250.52(A)1-2
Electrical
Electrical |
- |
pdf_text |
| 250.52 |
250.52(A)4-250.102(E)
Electrical
Electrical |
- |
pdf_text |
| 250.52 |
250.52(A)3
Electrical/Building
Building |
- |
pdf_text |
| 250.52 |
250.52(A)4-250.102(E)
Electrical
Electrical |
- |
pdf_text |
| 26 |
26. In section 1103.12.3.2, entitled "Height," delete the exception in its entiret
insert the following in its place: "Exception: A counter that is adjustable or rep |
- |
pdf_text |
| 26 |
26. Chapter 35, Referenced Standards, shall be amended as follows:
i. In the User notes, under About This Chapter, "Section 102.4" shall be deleted a
administrative provisions of the Uniform Construction Code (N.J.A.C. 5:23)" shall
inserted in its place.
ii. Under the heading ASME, add the following note:
Note: Those sections of ANSI A17.1/CSA B44 that are noted as applicable in
are not included as part of the referenced document. |
- |
pdf_text |
| 26 |
26. The Appendices shall be amended as follows:
i. Appendix A, Employee Qualifications; Appendix B, Board of Appeals; Appen
Group U-Agricultural Buildings; Appendix D, Fire Districts; Appendix E, Supple
Accessibility Requirements; Appendix F, Rodentproofing; and Appendix G, Flood
Resistant Construction, shall be deleted in their entirety.
ii. At Appendix H, Signs, at the beginning of the Appendix, the sentence, "The pr
contained in this appendix are not mandatory unless specifically referenced in the
ordinance," shall be deleted in its entirety.
(1) In Appendix H, Section H101.2, Signs exempt from permits, shall be dele
entirety.
(2) In Appendix H, Section H105.2, Permits, drawings and specifications, "as
provided in Chapter 1" shall be deleted and "as provided in N.J.A.C. 5:23-2.14
be inserted.
iii. Appendix I, Patio Covers, Appendix J, Grading, Appendix K, Administrative
Provisions, Appendix L, Earthquake Recording Instrumentation, Appendix M, Tsu |
- |
pdf_text |
| 2601-2602 |
2601-2602
Building
Building |
- |
pdf_text |
| 2601-2602 |
2601-2602
Building
Building |
- |
pdf_text |
| 2603-2607 |
2603-2607
Building/Fire
Building |
- |
pdf_text |
| 2603-2607 |
2603-2607
Building/Fire
Building |
- |
pdf_text |
| 2608-2611 |
2608-2611
Building
Building |
- |
pdf_text |
| 2608-2611 |
2608-2611
Building
Building |
- |
pdf_text |
| 2612-2614 |
2612-2614
Building/Fire
Building
C
h.
Electrical |
- |
pdf_text |
| 2612-2614 |
2612-2614
Building/Fire
Building
Ch. |
- |
pdf_text |
| 27 |
27. In section 1103.12.4.1, entitled "Clear Floor Space," delete Exception 2.1 i
entirety and insert in its place: "2.1 the cabinetry can be removed or replaced a
unit,". |
- |
pdf_text |
| 27 |
27. The Appendices shall be amended as follows:
i. Appendix A, Employee Qualifications; Appendix B, Board of Appeals; Append
Group U-Agricultural Buildings; Appendix D, Fire Districts; Appendix E, Supple
Accessibility Requirements; Appendix F, Rodentproofing; and Appendix G, Flood
Resistant Construction, shall be deleted in their entirety.
ii. In Appendix H, at the beginning of the Appendix, the sentence, "The provision
contained in this appendix are not mandatory unless specifically referenced in the
ordinance," shall be deleted in its entirety.
(1) In Appendix H, Section H101.2, Signs exempt from permits, shall be delet
entirety.
(2) In Appendix H, Section H105.2, Permits, drawings and specifications, "as
in Chapter 1" shall be deleted and "as provided in N.J.A.C. 5:23-2.14" shall be
iii. Appendix I, Patio Covers, Appendix J, Grading, Appendix K, Administrative
Provisions, Appendix L, Earthquake Recording Instrumentation, Appendix M, Tsu
Generated Flood Hazard, Appendix N, Replicable Buildings, and Appendix O,
Performance-based application, shall be deleted in their entirety.
History
HISTORY: |
- |
pdf_text |
| 2702.1.1 |
2702.1.1
Fire/Electrical
Electrical |
- |
pdf_text |
| 2702.1.1 |
2702.1.1
Fire/Electrical
Electrical |
- |
pdf_text |
| 2702.1.2 |
2702.1.2
Building/Fire
Fire |
- |
pdf_text |
| 2702.1.2 |
2702.1.2
Building/Fire
Fire |
- |
pdf_text |
| 2702.1.3-2702.1.6 |
2702.1.3-2702.1.6
Electrical
Electrical |
- |
pdf_text |
| 2702.1.3-2702.1.6 |
2702.1.3-2702.1.6
Electrical
Electrical |
- |
pdf_text |
| 2702.1.7-2702.1.8 |
2702.1.7-2702.1.8
Building/Electri
cal
Electrical |
- |
pdf_text |
| 2702.1.7-2702.1.8 |
2702.1.7-2702.1.8
Building/Electri
cal
Electrical |
- |
pdf_text |
| 2702.2 |
2702.2
As applicable
As applicable |
- |
pdf_text |
| 2702.2 |
2702.2
As applicable
As applicable |
- |
pdf_text |
| 2702.3 |
2702.3
Electrical
Electrical
Ch. |
- |
pdf_text |
| 2702.3 |
2702.3
Building/Electri
cal
Building for #3;
Electrical for #1 and #2 |
- |
pdf_text |
| 2703 |
2703
Electrical
Electrical
C
h.
Elevators and |
- |
pdf_text |
| 28 |
28. In section 1103.12.4.2, entitled "Height," delete the exception in its entiret
insert the following in its place: "Exception: A sink and counter that is adjusta
replaceable as a unit at heights between 29 inches minimum and 36 inches ma
provided rough-in plumbing permits connections of supply and drain piping fo
mounted at heights of 29 inches, shall be permitted." |
- |
pdf_text |
| 29 |
29
Water Supply
and Distribution< |
- |
pdf_text |
| 29 |
29
and Distribution<2>
P2904.1
Plumbing/Fire
Plumbing
P2904.1.1-P2904.2.2
Fire
Fire
P2904.2.3
Plumbing
Plumbing
P2904.2.4-P2904.2.6
Fire
Fire
P2904.3-P2904.3.3
Plumbing
Plumbing
P2904.3.4
Fire/Plumbing
Plumbing
P2904.4
Fire/Plumbing
Fire
P2904.5-P2904.6
Fire/Plumbing
Plumbing
P2904.7
Fire/Plumbing
Fire |
- |
pdf_text |
| 29 |
29. In section 1103.12.5, entitled "Appliances," delete the following sections: |
- |
pdf_text |
| 3 |
3
General Requirements
Building
Building
(R
E)
C
h. |
- |
pdf_text |
| 3 |
3. Plumbing materials/supplies:
i. All purpose solvent cement, except transition glues permitted in the plumbing s
ii. Clear PB piping;
iii. Flexible traps and tailpieces;
iv. Sheet and tubular copper and brass trap and tailpiece fittings less than B & S 1
(.045 in.);
v. Water closets requiring in excess of an average of 1.6 gallons per flush, that eit
a manufacturer's date stamp of July 1, 1991, or later, or were not purchased by the
distributor prior to July 1, 1991, or as required pursuant to N.J.S.A. 52:27D-141.2
whichever is more restrictive;
vi. Plumbing fixtures that do not meet the standards listed in the plumbing subcod |
- |
pdf_text |
| 3 |
3. No construction permit shall be issued for a public school facility unless and until t
plans and specifications have been released by the Department or an appropriately clas
municipal code enforcing agency. |
- |
pdf_text |
| 3 |
3. Eave height of 10 feet (3048 mm) or less.
iv. In Section R403.3.3, Drainage, "Table R405.1" shall be deleted and "Table R4
shall be inserted. |
- |
pdf_text |
| 3 |
3. Trade name or kind of chemical used in treatment. |
- |
pdf_text |
| 3 |
3. The Commissioner hereby adopts the National Electrical Safety Code (ANSI C2-2
the installation of area lighting facilities by an electric utility on private property on m
poles with an underground electric feed.
i. Copies of the National Electrical Safety Code may be obtained from the Institut
Electrical and Electronic Engineers, Inc., PO Box 1331, 445 Hoes Lane, Piscatawa
Jersey 08855-1331.
(b) The following chapters or articles of the electrical subcode are amended, as follows: |
- |
pdf_text |
| 3 |
3 and" shall be deleted. Additionally, in the heading over the 3rd, 4th, and 5th row,
"Common Path of Egress" shall be deleted and "Exit Access" shall be inserted.
vii. In Section 1006.2.1, Egress based on occupancy load and common path of egr
travel distance, in the title and the first sentence, "common path of egress" shall be
and "exit access" shall be inserted. Additionally, in Table 1006.2.1, Spaces with on
exit access doorway, in the heading over the 3rd, 4th, and 5th row, in footnote e an
footnote f, "Common Path of Egress" shall be deleted, and "Exit Access" shall be i
Lastly, in the 5th column of the 10th row (R-3), the reference to footnote a and g s
deleted; and in footnote g, "R-3 and" shall be deleted.
viii. Section 1008.2.3, Exit discharge, is deleted. |
- |
pdf_text |
| 3 |
3. Chapter 3, Building Planning, shall be amended as follows:
i. Add new Section R300 as follows:
"R300 Height and Area Limitations
R300.1 General. Buildings of VB, unprotected wood framed construction,
term is defined in Section 602 of the building subcode, shall be not more th
stories, not more than 35 feet in height, and not more than 4,800 square fee
per floor. For the purpose of applying this subsection, a habitable attic shal
constitute a story in a two-story dwelling.
R300.2 Increases in height. The building shall be not more than three stori
not more than 55 feet in height where the building is equipped throughout
automatic sprinkler system installed in accordance with the National Fire P
Association (NFPA) Standard 13D or Section P2904.
R300.3 Increases in area. The area of a building may be increased as provi
Sections R300.3.1 and Section R300.3.2 below.
R300.3.1 Automatic sprinkler system. The area limitation shall be unlimit
a building is equipped throughout with an automatic sprinkler system instal
accordance with NFPA Standard 13D or Section P2904.
R300.3.2 Frontage. The area limitation shall be permitted to be increased t
percent for each one percent of excess frontage where a building has more
percent of the building perimeter fronting on a street or other unoccupied s
The unoccupied space shall be on the same lot or dedicated for public use,
not less than 30 feet in width, and shall have access from a street by a poste
lane that is not |
- |
pdf_text |
| 3 |
3
General
Regulations |
- |
pdf_text |
| 3 |
3. Chapter 3, General Requirements, shall be amended as follows:
i. Section R303.3, Maintenance information, shall be deleted. |
- |
pdf_text |
| 3 |
3. Trade name or kind of chemical used in treatment. |
- |
pdf_text |
| 3 |
3. Chapter 3, General Compliance, shall be amended as follows: |
- |
pdf_text |
| 3 |
3 and" shall be deleted.
vii. Section 1008.2.3, Exit discharge, is deleted. |
- |
pdf_text |
| 3 |
3. Chapter 3, General Requirements, shall be deleted, unless referenced for complianc
optional appendix. |
- |
pdf_text |
| 3 |
3. Eave height of 10 feet (3048 mm) or less.
iv. In Section R404.4, Retaining walls, in the first sentence, "that are not laterally
supported at the top and that retain in excess of 48 inches (1219 mm) of unbalance
retaining walls exceeding 24 inches (610 mm) in height that resist lateral loads in a
to soil" shall be deleted and "for which a construction permit is required by N.J.A. |
- |
pdf_text |
| 3 |
3. Equivalent facilitation and protection for people with disabilities are sec |
- |
pdf_text |
| 3 |
3
General Requirements
Building
Building
(R
E)
C
Residential Energy Efficiency |
- |
pdf_text |
| 3 |
3
Materials
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 3 |
3. For occupancies in Group B, I, R-1 or R-2 in buildings that are equippe
throughout with an automatic sprinkler system in accordance with Section |
- |
pdf_text |
| 3 |
3, "capable of being secured, locked or removed to prevent access exce
the ladder or steps are" shall be deleted. |
- |
pdf_text |
| 3 |
3. Tanks used to store heating oil for onsite consumption in a residential building; |
- |
pdf_text |
| 3 |
3. Chapter 3, General Requirements, shall be deleted. |
- |
pdf_text |
| 3 |
3. Rehabilitation subcode code change proposals may be submitted on the form provi
subchapter Appendix 3-A, incorporated herein by reference. |
- |
pdf_text |
| 3 |
3. Pre-engineered grain bins, manure handling equipment and impoundments used on
for the storage of agricultural commodities or by-products which are produced by or u
the farm shall not require a construction permit. However, all on-site construction wor
foundations and plumbing and electrical connections shall be subject to all requiremen
inspections of any applicable subcode(s). |
- |
pdf_text |
| 3 |
3. Automatic dry and semiautomatic dry standpipes are allowed as provide
NFPA 14.
xxviii. Section 905.3.2, Group A, shall be renumbered as 905.3.3 with no change i |
- |
pdf_text |
| 3 |
3. The length of the trap arm for the bathtub or shower stall is with
limits of Table 12.8.1. If not, the bathtub or shower stall shall be
individually vented. |
- |
pdf_text |
| 3 |
3. The distance from the outlet of the floor drain or floor sink to th
connection of the wet vent shall be within the limits established by |
- |
pdf_text |
| 3 |
3. Chapter 3, General Compliance, shall be amended as follows: |
- |
pdf_text |
| 3 |
3. Chapter 3 of the mechanical subcode, entitled "General Regulations," shall be ame
follows:
i. Section 301.1, Scope, is amended to delete the words "in accordance with Secti |
- |
pdf_text |
| 3 |
3. Detached one and two-family residential structures with truss construction that are
of a planned real estate development shall be exempt from the requirements of (e) abo
unless required by municipal ordinance. |
- |
pdf_text |
| 3 |
3. The organization of enforcement responsibilities. |
- |
pdf_text |
| 3 |
3. A hearing shall thereafter be held in accordance with N.J.S.A. 52:27D-124 of the A |
- |
pdf_text |
| 3 |
3. An automatic sprinkler system with less than 20 sprinklers."
lxi. New Section 912.1A, Connections, shall be inserted between Sections 912 |
- |
pdf_text |
| 3 |
3. Electrical Subcode:
Chapte
r
Section/Title
Responsibility
Plan Review
Inspection
Article
Introduction
Electrical
Electrical |
- |
pdf_text |
| 3 |
3. Chapter 2 of the plumbing subcode, entitled "General Regulations," shall be amend
follows:
i. Section 2.5, Health and Safety, is deleted in its entirety.
ii. At Section 2.9.3, From Weakened Structure, delete " code" and insert " subcod
iii. In Section 2.11, Materials Exposed Within Plenums, "Codes" shall be deleted
"subcodes" shall be inserted.
iv. In Section 2.12, Sleeves for Piping, subparagraph e, "regulations" shall be dele
"subcode" shall be inserted.
v. In Section 2.16, Freezing or Overheating, at Item 1, "42" shall be inserted in the
space provided. Additionally, the following shall be inserted: "Combination domes
water service piping shall be installed such that the minimum earth cover is 42 inc
the top of the pipe is 12 inches below the frost depth of the locality, whichever is g
Limited-area sprinkler systems installed in accordance with Section 903.3.8 of the
subcode, shall be installed such that the minimum earth cover is 42 inches." In the |
- |
pdf_text |
| 3 |
3. Automatic dry and semiautomatic dry standpipes are allowed as provide
NFPA 14."
xxv. Section 905.3.3, Covered and open mall buildings, "or 905.3.1A" shall be ad
"905.3.1" in the first and second sentence.
xxvi. At Section 905.4, Location of Class I standpipe hose connections, Item 1 sh
deleted, and Section 915.7 of the 1996 BOCA National Building Code shall be ins
follows: "A standpipe hose connection shall be located at each floor level at every
stairway, and on each side of the wall adjacent to the exit opening of a horizontal e
Exceptions |
- |
pdf_text |
| 3 |
3. Anywhere the term "code" appears, shall be a reference to "subcode" as defined in |
- |
pdf_text |
| 3 |
3. Chapter 3 of the fuel gas subcode, entitled "General Regulations," shall be amende
follows:
i. Section 301.1, Scope, is amended to delete the words "in accordance with Secti |
- |
pdf_text |
| 3 |
3. Locations of alarm notification appliances, including candela ratings for
alarm notification appliances. |
- |
pdf_text |
| 3 |
3. Plumbing materials/supplies:
i. All purpose solvent cement, except transition glues permitted in the plumbing s
ii. Clear PB piping;
iii. Flexible traps and tailpieces;
iv. Sheet and tubular copper and brass trap and tailpiece fittings less than B & S 1
(.045 in.);
v. Water closets requiring in excess of an average of 1.6 gallons per flush, that eit
a manufacturer's date stamp of July 1, 1991 or later or were not purchased by the
distributor prior to July 1, 1991;
vi. Plumbing fixtures that do not meet the standards listed in the plumbing subcod |
- |
pdf_text |
| 3 |
3. Under the heading of "Wind Design--Topographic effects," insert "N/A" for
Applicable; |
- |
pdf_text |
| 3 |
3. Solid waste disposal plants; |
- |
pdf_text |
| 3 |
3. Chapter 3, Use and Occupancy Classification, shall be amended as follows:
i. In Table 307.1(2), Maximum Allowable Quantity Per Control Area of Hazardou
Materials Posing a Health Hazard, the following shall be inserted as the fourth row
table under "Material," "Storage," "Use-Closed Systems," and "Use-Open Systems
Radioactive<j> |
- |
pdf_text |
| 3 |
3. Chapter 2 of the electrical subcode, entitled "Wiring and Protection," is amended as
follows: |
- |
pdf_text |
| 3 |
3
Use and Occupancy
Building/Fire
Building
Classification
Ch. |
- |
pdf_text |
| 3 |
3. Chapter 2 of the electrical subcode, entitled "Wiring and Protection," is amended as
follows:
i. Section 210.12(E), entitled "Branch Circuit Wiring Extensions or Modifications
Replacements "is deleted in its entirety.
ii. Section 225.41, entitled "Emergency Disconnects," shall be deleted in its entire |
- |
pdf_text |
| 3 |
3. In section 107.5, delete the definitions of "Administrative Authority", "Exis
building", and "Existing Facility"; |
- |
pdf_text |
| 3 |
3. For occupancies in Group B, I, R-1 or R-2 in buildings that are equip
throughout with an automatic sprinkler system in accordance with Secti |
- |
pdf_text |
| 3 |
3. Inspections: Such official(s) shall make all the required inspections, and all reports
inspections shall be in writing and certified by them or they may engage such expert o |
- |
pdf_text |
| 3 |
3. Billboards located on land owned or controlled by any State, county or local depart
agency, board, commission, authority, or instrumentality; and |
- |
pdf_text |
| 3 |
3
Building
Planning
R300
Building/Fire
Building |
- |
pdf_text |
| 3 |
3. The publication "Guidelines for Design and Construction of Health Care Facilities"
available from the American Society for Healthcare Engineering (ASHE) of the Amer
Hospital Association, 155 Wacker Dr., Chicago, IL 60606 and can be ordered through
Facilities Guidelines Institute at www.fgiguidelines.org. |
- |
pdf_text |
| 3 |
3
Materials
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 3 |
3
Planning
R300
Building/Fire
Building
R301
Building
Building
R302
Building/Fire
Building
(Except penetrations
in existing membranes
for electrical outlets
or devices pursuant to |
- |
pdf_text |
| 3 |
3
General
Regulations |
- |
pdf_text |
| 3 |
3. Equivalent facilitation and protection for people with disabilities are |
- |
pdf_text |
| 3 |
3. Electrical Subcode:
Chapte
r
Section/Title
Responsibility
Inspection
Plan Review
Article
Introduction
Electrical
Electrical |
- |
pdf_text |
| 3 |
3
General Regulations |
- |
pdf_text |
| 3 |
3
Use and Occupancy
Building/Fire
Building
Classification
C
h. |
- |
pdf_text |
| 3 |
3. Chapter 3, Building Planning, shall be amended as follows:
i. Add new Section R300 as follows:
"R300 Height and Area Limitations
R300.1 General. Buildings of VB, unprotected wood framed construction,
term is defined in Section 602 of the building subcode, shall be not more th
stories, not more than 35 feet in height, and not more than 4,800 square fee
per floor. For the purpose of applying this subsection, a habitable attic shal
constitute a story in a two-story dwelling.
R300.2 Increases in height. The building shall be not more than three stori
not more than 55 feet in height where the building is equipped throughout |
- |
pdf_text |
| 3 |
3. Chapter 2 of the plumbing subcode, entitled "General Regulations," shall be amend
follows:
i. Section 2.5, Health and Safety, is deleted in its entirety.
ii. In Section 2.9.3, From Weakened Structure, delete "building code" and insert "
subcode."
iii. In Section 2.11, Materials Exposed Within Plenums, "Codes" shall be deleted
"subcodes" shall be inserted.
iv. In Section 2.12, Sleeves for Piping, subparagraph e, "regulations" shall be dele
"subcode" shall be inserted.
v. In Section 2.16, Freezing or Overheating, at Item 1, "42" shall be inserted in the
space provided. Additionally, the following shall be inserted: "Combination domes
water service piping shall be installed such that the minimum earth cover is 42 inc
the top of the pipe is 12 inches below the frost depth of the locality, whichever is g
Limited-area sprinkler systems installed in accordance with Section 903.3.8 of the |
- |
pdf_text |
| 3 |
3. An automatic sprinkler system with less than 20 sprinklers."
lxvii. New section 912.2, Connections, shall be inserted as follows:
"912.2 Connections: Fire department connections shall be arranged in such a m
that the attachment to any one sprinkler connection will serve all sprinklers, an
attachment to any one standpipe connection will serve all standpipes within the
building.
Exception: Fire protection systems in high rise buildings designed with a l
and a high zone may be provided with a connection for each zone."
lxviii. Section 912.2, Location, shall be renumbered as 912.3 and "fire protection
official in coordination with the" shall be inserted before "fire code official" in the
sentence.
lxix. Section 912.2.1, Visible location, shall be renumbered 912.3.1 and "or as oth
approved by the fire code official" shall be deleted.
lxx. Section 912.2.2, Existing buildings, shall be deleted in its entirety.
lxxi. New Section 912.4, Height, shall be inserted as follows:
"912.4, Height. Fire department connections shall not be less than 18 inches (
and more than 42 inches (1,067 mm) in elevation, measured from the ground le
centerline of the inlets."
lxxii. Section 912.3, Fire hose threads, shall be renumbered as 912.5.
lxxiii. Section 912.4, Access, shall be renumbered as 912.6. Additionally, in the la
sentence of the section and the last sentence of the exception, "fire code official" s
deleted and "fire protection subcode official" shall be ins |
- |
pdf_text |
| 3 |
3. Anywhere the term "code" appears, shall be a reference to "subcode" as defined at |
- |
pdf_text |
| 3 (cont. 2) |
less than 18 feet in width.
R300.4 Buildings of VA construction. Buildings of VA, protected wood fr
construction, as that term is defined in Section 602 of the building subcode |
- |
pdf_text |
| 3.1 |
3.1 In Section 302.1, Electrical, "NFPA 70" shall be deleted and "the el
subcode (N.J.A.C. 5:23-3.16)" shall be inserted. Additionally, "or the
International Residential Code, as applicable in accordance with Sectio |
- |
pdf_text |
| 3.1 |
3.1 At Section 302.1, Electrical, "NFPA 70" shall be deleted and "the elect
subcode (N.J.A.C. 5:23- 3.16)" shall be inserted. Additionally, "or the Inter
Residential Code, as applicable in accordance with Section 102.7.1" shall b
deleted. |
- |
pdf_text |
| 3.1 |
3.1 In Section 302.1, Electrical, "NFPA 70" shall be deleted and "the e
subcode (N.J.A.C. 5:23-3.16)" shall be inserted. Additionally, "or the
International Residential Code, as applicable in accordance with Sectio |
- |
pdf_text |
| 3.10 |
3.10 In Section 318.2, Protection of potable water supply, "Internation
Residential Code or the International Plumbing Code or, as applicable i
accordance with Section 102.7.1" shall be deleted and "plumbing subco
(N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 3.10 |
3.10 In Section 318.2, Protection of potable water supply, "Internationa
Residential Code or the International Plumbing Code or, as applicable i
accordance with Section 102.7.1" shall be deleted and "plumbing subco
(N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 3.10 |
3.10 At Section 317.4, Installation, "in accordance with Section 102.7.1
be deleted. Additionally, "NFPA 70" shall be deleted and "the electrica
subcode (N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 3.10 |
3.10 At Section 317.4, Installation, "in accordance with Section 102.7.1" s
deleted. Additionally, "NFPA 70" shall be deleted and "the electrical subco
(N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 3.11 |
3.11 At Section 319.2, Protection of potable water supply, "International
Residential Code or the International Plumbing Code or, as applicable in
accordance with Section 102.7.1" shall be deleted and "plumbing subcode
(N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 3.11 |
3.11 At Section 319.2, Protection of potable water supply, "Internation
Residential Code or the International Plumbing Code or, as applicable i
accordance with Section 102.7.1" shall be deleted and "plumbing subco
(N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 3.11 |
3.11 In Section 321.2.1, Pool and deck illumination, in the second sent
"NFPA 70" shall be deleted and "the electrical subcode (N.J.A.C. 5:23-
shall be inserted. |
- |
pdf_text |
| 3.11 |
3.11 In Section 321.2.1, Pool and deck illumination, in the second sente
"NFPA 70" shall be deleted and "the electrical subcode (N.J.A.C. 5:23-
shall be inserted. |
- |
pdf_text |
| 3.12 |
3.12 In Section 321.4, Residential pool and deck illumination, "NFPA
be deleted and "the electrical subcode (N.J.A.C. 5:23-3.16)" shall be in
Additionally, "or the International Residential Code, as applicable in
accordance with Section 102.7.1" shall be deleted. |
- |
pdf_text |
| 3.12 |
3.12 In Section 321.4, Residential pool and deck illumination, "NFPA
be deleted and "the electrical subcode (N.J.A.C. 5:23-3.16)" shall be in |
- |
pdf_text |
| 3.12 |
3.12 At Section 322.2.1, Pool and deck illumination, in the second sentenc
"NFPA 70" shall be deleted and "the electrical subcode (N.J.A.C. 5:23-3.1
be inserted. |
- |
pdf_text |
| 3.12 |
3.12 At Section 322.2.1, Pool and deck illumination, in the second sent
"NFPA 70" shall be deleted and "the electrical subcode (N.J.A.C. 5:23-
shall be inserted. |
- |
pdf_text |
| 3.13 |
3.13 At Section 322.4, Residential pool and deck illumination, "NFPA 70"
deleted and "the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
Additionally, "or the International Residential Code, as applicable in accor
with Section 102.7.1" shall be deleted. |
- |
pdf_text |
| 3.13 |
3.13 In Section 324.4, Electrical, "NFPA 70" shall be deleted and "the
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 3.13 |
3.13 At Section 322.4, Residential pool and deck illumination, "NFPA
be deleted and "the electrical subcode (N.J.A.C. 5:23-3.16)" shall be in
Additionally, "or the International Residential Code, as applicable in
accordance with Section 102.7.1" shall be deleted. |
- |
pdf_text |
| 3.14 |
3.14)."
ii. In Section 7.18.2, Approval, "to the Authority Having Jurisdiction" shall be del |
- |
pdf_text |
| 3.14 |
3.14(b)2 shall be inserted:
"BUILDING. A structure enclosed with exterior walls or fire walls, built, ere
framed of component structural parts, designed for the housing shelter, enclo
support of individuals, animals or property of any kind. When used herein, buil
structure shall be interchangeable except where the context clearly indicates other
vi. The definition of the term "code" is deleted.
vii. The definition of the term "code official" is deleted.
viii. In the definition of "Dwelling Unit," "living as a single housekeeping unit" sh
inserted after "persons." |
- |
pdf_text |
| 3.14 |
3.14 At Section 325.4, Electrical, "NFPA 70" shall be deleted, and "the
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 3.14 |
3.14 At Section 325.4, Electrical, "NFPA 70" shall be deleted, and "the ele
subcode (N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 3.14 |
3.14(b)2 shall be inserted: |
- |
pdf_text |
| 3.14 |
3.14(b)2 shall be inserted:
"BUILDING. A structure enclosed with exterior walls or fire walls, built, erect
framed of component structural parts, designed for the housing shelter, enclosu
support of individuals, animals or property of any kind. When used herein, buil
structure shall be interchangeable except where the context clearly indicates
otherwise."
vi. The definition of "Code Official" shall be deleted.
vii. In the definition of "Dwelling Unit," "living as a single housekeeping unit" sh
inserted after "persons."
viii. The definitions of "Historic Building," "Repair," "Reroofing," "Roof Recover
Repair," and "Roof Replacement" shall be deleted.
ix. New definition of "IECC-Commercial Provisions" shall be inserted and define
meeting the requirements of the ASHRAE Standard 90.1 referenced by Chapter 6
commercial provisions of this code. |
- |
pdf_text |
| 3.14 |
3.14(b)2 shall be inserted:
"BUILDING. A structure enclosed with exterior walls or fire walls, built, ere
framed of component structural parts, designed for the housing shelter, enclo
support of individuals, animals or property of any kind. When used herein, buil
structure shall be interchangeable except where the context clearly indicates other
vi. The definition of the term "code" is deleted.
vii. The definition of the term "code official" is deleted.
viii. In the definition of "Dwelling Unit," "living as a single housekeeping unit" sh
inserted after "persons."
ix. The definition of the term "peer review" is deleted. |
- |
pdf_text |
| 3.15 |
3.15)" shall be inserted. "Additionally, within the exception "Table R405.1" shall
deleted and "Table R406.1" shall be inserted.
xvii. Sections R310.5, Replacement windows for emergency escape and rescue op
R310.6, Dwelling additions, and R310.7, Alterations or repairs of existing baseme
R310.7.1, Existing emergency escape rescue openings, shall be deleted.
xviii. In Section R311.3.1, Floor elevations at the required egress doors, in the Ex
"7 3/4 inches (196 mm)" shall be deleted and "8 1/4 inches (210 mm)" shall be ins
Also, in Section R311.3.2, Floor elevations at other exterior doors, "7 3/4 inches (
mm)" shall be deleted and "8 1/4 inches (210 mm)" shall be inserted."
xix. In Section R311.7.5.1, Risers, "7 3/4 inches (196 mm)" shall be deleted and "
inches (210 mm)" shall be inserted.
xx. In Sections R311.7.5.2, Treads, and R311.7.5.2.1, Winder treads, "10 inches (
mm)" shall be deleted and "9 inches (229 mm)" shall be inserted. |
- |
pdf_text |
| 3.15 |
3.15." shall be inserted. |
- |
pdf_text |
| 3.15 |
3.15)." shall be inserted.
(2) In Section P2904.2.3, Freezing areas, "Section P2603.5" shall be deleted a
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
(3) In Section P2904.8.1, Preconcealment Inspection, item 8, "Section P2503.
be deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 3.15 |
3.15" shall be inserted. |
- |
pdf_text |
| 3.15 |
3.15)" shall be inserted.
lxxix. New Section 912.9, Projection, shall be inserted as follows: "912.9 Projecti
Where the fire department connection will otherwise project beyond the property l
into the public way, a flush-type fire department connection shall be provided."
lxxx. Section 913.2.2, Circuits supplying fire pumps, shall be deleted in its entiret
lxxxi. Section 913.4.1, Test outlet valve supervision, shall be deleted.
lxxxii. In Section 915.1, General, the last sentence shall be deleted.
lxxxiii. In Section 915.1.1, Where required, "in Group I-1, I-2, I-4 and R occupan
in classrooms in Group E occupancies" shall be deleted.
lxxxiv. In 915.1.2, Fuel-burning appliances and fuel-burning fireplaces, the word
shall be deleted before "classrooms" and the words "or any other occupiable space
be added following "classrooms."
lxxxv. In 915.1.3, Fuel-burning, forced-air furnaces, and in the exception, the wor
shall be deleted before "classrooms" and the words "or any other occupiable space
be added following "classrooms." |
- |
pdf_text |
| 3.16 |
3.16." shall be inserted. |
- |
pdf_text |
| 3.2 |
3.2 At Section 302.2, Water service and drainage, "International Plumbing
shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inse |
- |
pdf_text |
| 3.2 |
3.2 In Section 302.2, Water service and drainage, "International Plumbi
Code" shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" s
inserted. |
- |
pdf_text |
| 3.2 |
3.2 In Section 302.2, Water service and drainage, "International Plumb
Code" shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" s
inserted. |
- |
pdf_text |
| 3.3 |
3.3 In Sections 302.5, Backflow prevention, and 302.6, Waste-water di
"International Plumbing Code or the International Residential Code, as
applicable in accordance with Section 102.7.1" shall be deleted and "pl
subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 3.3 |
3.3 In Sections 302.5, Backflow prevention, and 302.6, Waste-water di
"International Plumbing Code or the International Residential Code, as
applicable in accordance with Section 102.7.1" shall be deleted and "pl
subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 3.3 |
3.3 At Sections 302.5, Backflow prevention, and 302.6, Waste-water disch
"International Plumbing Code or the International Residential Code, as app |
- |
pdf_text |
| 3.4 |
3.4 At Section 303.1.3, Covers, "in accordance with Section 104.9.1" s
deleted. |
- |
pdf_text |
| 3.4 |
3.4 At Section 303.1.3, Covers, "in accordance with Section 104.9.1" shall
deleted. |
- |
pdf_text |
| 3.4 |
3.4 Section 305, Barrier requirements, shall be amended as follows: |
- |
pdf_text |
| 3.4 |
3.4 Section 305, Barrier requirements, shall be amended as follows: |
- |
pdf_text |
| 3.4 |
3.4, as the fire protection subcode for New Jersey.
i. International Building Code of the International Code Council, Inc., adopted as
at N.J.A.C. 5:23-3.14 as the building subcode:
(1) Chapter 3--Use and Occupancy Classification;
(2) Chapter 4--Special Detailed Requirements Based on Use and Occupancy;
(3) Chapter 5--General Building Heights and Areas;
(4) Chapter 6--Types of Construction;
(5) Chapter 7--Fire and Smoke Protection Features;
(6) Chapter 8--Interior Finishes;
(7) Chapter 9--Fire Protection and Life Safety Systems and N.J.A.C. 5:23-3.5(
Posted Hydraulic System Data Plate;
(8) Chapter 10--Means of Egress;
(9) Chapter 15--Roof Assemblies and Rooftop Structures; |
- |
pdf_text |
| 3.4.1 |
3.4.1 In Section 305.1, General, in the second sentence, "and swim
pools are equipped with a powered safety cover that complies with
F1346" shall be deleted. Also in the second sentence, ", hot tubs or
shall be replaced with "or hot tubs". |
- |
pdf_text |
| 3.4.1 |
3.4.1 In Section 305.1, General, in the second sentence, "and swim
pools are equipped with a powered safety cover that complies with
F1346" shall be deleted. Also in the second sentence, ", hot tubs or
shall be replaced with "or hot tubs". |
- |
pdf_text |
| 3.4.2 |
3.4.2 Section 305.1.1, Construction fencing required, shall be delet |
- |
pdf_text |
| 3.4.2 |
3.4.2 Section 305.1.1, Construction fencing required, shall be delete |
- |
pdf_text |
| 3.4.3 |
3.4.3 Section 305.4, Structure wall as a barrier, shall be deleted. |
- |
pdf_text |
| 3.4.3 |
3.4.3 Section 305.4, Structure wall as a barrier, shall be deleted. |
- |
pdf_text |
| 3.4.4 |
3.4.4 In Section 305.5, Onground residential pool structure as a barr
item 3, "capable of being secured, locked or removed to prevent acc
except where the ladder or steps are" shall be deleted. |
- |
pdf_text |
| 3.4.4 |
3.4.4 In Section 305.5, Onground residential pool structure as a bar
item 3, "capable of being secured, locked or removed to prevent acc
except where the ladder or steps are" shall be deleted. |
- |
pdf_text |
| 3.5 |
3.5 Section 305, Barrier requirements, shall be amended as follows: |
- |
pdf_text |
| 3.5 |
3.5 Section 305, Barrier requirements, shall be amended as follows: |
- |
pdf_text |
| 3.5 |
3.5 In Section 306.1, General, "in accordance with Section 102.7.1" sh
deleted. |
- |
pdf_text |
| 3.5 |
3.5 In Section 306.1, General, "in accordance with Section 102.7.1" sha
deleted. |
- |
pdf_text |
| 3.5.1 |
3.5.1 At Section 305.1, General, in the second sentence, "and swimmin
are equipped with a powered safety cover that complies with ASTM F1
shall be deleted. Also, in the second sentence, ", hot tubs or pools" shal
replaced with "or hot tubs". |
- |
pdf_text |
| 3.5.1 |
3.5.1 At Section 305.1, General, in the second sentence, "and swim
pools are equipped with a powered safety cover that complies with
F1346" shall be deleted. Also in the second sentence, ", hot tubs or
shall be replaced with "or hot tubs". |
- |
pdf_text |
| 3.5.2 |
3.5.2 Section 305.1.1, Construction fencing required, shall be delete |
- |
pdf_text |
| 3.5.2 |
3.5.2 Section 305.1.1, Construction fencing required, shall be deleted. |
- |
pdf_text |
| 3.5.3 |
3.5.3 Section 305.4, Structure wall as a barrier, shall be deleted. |
- |
pdf_text |
| 3.5.3 |
3.5.3 Section 305.4, Structure wall as a barrier, shall be deleted. |
- |
pdf_text |
| 3.5.4 |
3.5.4 At Section 305.5, Onground residential pool structure as a barrier |
- |
pdf_text |
| 3.5.4 |
3.5.4 At Section 305.5, Onground residential pool structure as a bar
item 3, "capable of being secured, locked or removed to prevent acc
except where the ladder or steps are" shall be deleted. |
- |
pdf_text |
| 3.6 |
3.6 Sections 306.3, Step risers and treads, and 306.4, Deck steps handra
required, shall be deleted. |
- |
pdf_text |
| 3.6 |
3.6 Sections 306.3, Step risers and treads, and 306.4, Deck steps handr
required, shall be deleted. |
- |
pdf_text |
| 3.6 |
3.6 At Section 306.1, General, "in accordance with Section 102.7" shall be |
- |
pdf_text |
| 3.6 |
3.6 At Section 306.1, General, "in accordance with Section 102.7" shall
deleted. |
- |
pdf_text |
| 3.7 |
3.7 Sections 306.3, Step risers and treads, and 306.4, Deck steps handrail r
shall be deleted. |
- |
pdf_text |
| 3.7 |
3.7 In Section 306.9.1, Hose bibbs, "International Plumbing Code or th
International Residential Code, as applicable in accordance with Sectio |
- |
pdf_text |
| 3.7 |
3.7 Sections 306.3, Step risers and treads, and 306.4, Deck steps handra
required, shall be deleted. |
- |
pdf_text |
| 3.7 |
3.7 In Section 306.9.1, Hose bibbs, "International Plumbing Code or th
International Residential Code, as applicable in accordance with Sectio |
- |
pdf_text |
| 3.8 |
3.8 In Sections 307.1.1, Glazing in hazardous locations, 307.1.3, Roofs
canopies, 307.2.2, Materials and structural design, and 316.6.1, Installa
accordance with Section 102.7.1" shall be deleted. |
- |
pdf_text |
| 3.8 |
3.8 and 3.8A" following "5:23-3.7"; in the introductory paragraph of (b)3i, substituted "210.8(A)(
"210.8 (A)2"; in (b)3i, inserted the last paragraph; added (b)3ii; deleted (b)4ii, (b)4iv and (b)4v; r
(b)4iii as (b)4ii; added new (b)5; recodified former (b)5 through (b)8 as (b)6 through (b)9; rewrot
and in (b)9, inserted "Informative".
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote (a) and (b).
Administrative correction.
See: 47 N.J.R. 2669(b).
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Amended by R.2021 d.004, effective January 4, 2021.
See: 52 N.J.R. 385(a), 53 N.J.R. 47(a).
In (a)2i, substituted "19-3" for "15-2"; in (b)7v, inserted "and" at the end; and, deleted (b)7vii. |
- |
pdf_text |
| 3.8 |
3.8 At Section 306.9.1, Hose bibbs, "International Plumbing Code or the
International Residential Code, as applicable in accordance with Section 10
shall be deleted and "plumbing subcode (N.J.A.C. 5:23- 3.15)" shall be ins |
- |
pdf_text |
| 3.8 |
3.8 and 3.8A" following "5:23-3.7"; in the introductory paragraph of (b)3i, substituted "210.8(A)(
"210.8 (A)2"; in (b)3i, inserted the last paragraph; added (b)3ii; deleted (b)4ii, (b)4iv and (b)4v; r
(b)4iii as (b)4ii; added new (b)5; recodified former (b)5 through (b)8 as (b)6 through (b)9; rewrot
and in (b)9, inserted "Informative".
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote (a) and (b).
Administrative correction.
See: 47 N.J.R. 2669(b).
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Amended by R.2021 d.004, effective January 4, 2021.
See: 52 N.J.R. 385(a), 53 N.J.R. 47(a).
In (a)2i, substituted "19-3" for "15-2"; in (b)7v, inserted "and" at the end; and, deleted (b)7vii.
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Amended by R.2023 d.138, effective December 4, 2023.
See: 55 N.J.R. 1056(a), 55 N.J.R. 2403(a).
Rewrote (a)2; in the introductory paragraph of (b), inserted a comma; in (b)7, inserted a comma
following "amended"; added new (b)7vi and recodified former (b)7vi to (b)7vii.
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a). |
- |
pdf_text |
| 3.8 |
3.8 In Sections 307.1.1, Glazing in hazardous locations, 307.1.3, Roofs
canopies, 307.2.2, Materials and structural design, and 316.6.1, Installa
accordance with Section 102.7.1" shall be deleted. |
- |
pdf_text |
| 3.8 |
3.8 At Section 306.9.1, Hose bibbs, "International Plumbing Code or th
International Residential Code, as applicable in accordance with Sectio |
- |
pdf_text |
| 3.9 |
3.9 At Sections 307.1.1, Glazing in hazardous locations, 307.1.4, Roofs or
canopies, 307.2.2, Materials and structural design, and 317.6.1, Installation
accordance with Section 102.7.1" shall be deleted. |
- |
pdf_text |
| 3.9 |
3.9 In Section 316.4, Installation, "in accordance with Section 102.7.1"
deleted. Additionally, "NFPA 70" shall be deleted and "the electrical su
(N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 3.9 |
3.9 In Section 316.4, Installation, "in accordance with Section 102.7.1"
deleted. Additionally, "NFPA 70" shall be deleted and "the electrical su
(N.J.A.C. 5:23-3.16)" shall be inserted. |
- |
pdf_text |
| 3.9 |
3.9 At Sections 307.1.1, Glazing in hazardous locations, 307.1.4, Roofs
canopies, 307.2.2, Materials and structural design, and 317.6.1, Installa
accordance with Section 102.7.1" shall be deleted. |
- |
pdf_text |
| 30 |
30
Elevators and
Conveying Systems |
- |
pdf_text |
| 30 |
30
Conveying Systems |
- |
pdf_text |
| 30 |
30. Delete section 1104, entitled "Type B Units," in its entirety. |
- |
pdf_text |
| 300.1 |
300.1 to 300.20
Electrical
Electrical |
- |
pdf_text |
| 300.1 |
300.1 to 300.20
Electrical
Electrical |
- |
pdf_text |
| 300.21 |
300.21
Electrical/Fire
Electrical |
- |
pdf_text |
| 300.21 |
300.21
Electrical/Fire
Electrical |
- |
pdf_text |
| 300.22-398 |
300.22-398
Electrical
Electrical
Ch. 4
Equipment for General Use |
- |
pdf_text |
| 300.22-399 |
300.22-399
Electrical
Electrical
Ch. 4
Equipment for General Use |
- |
pdf_text |
| 3001.1 |
3001.1
Building/Elevat
or
Elevator |
- |
pdf_text |
| 3001.1 |
3001.1
Building
Elevator |
- |
pdf_text |
| 3001.2 |
3001.2
Building/Fire/E
levator
Elevator |
- |
pdf_text |
| 3001.3 |
3001.3
Building for
Building for devices not
devices not
under the scope of the
under the scope
elevator subcode/Elevator for
of the elevator
devices under the elevator
subcode/Elevat
or
subcode
for devices
under the
elevator
subcode |
- |
pdf_text |
| 3001.3 |
3001.3
Building for
Building for devices not
devices not
under the scope of the
under the scope
elevator subcode/Elevator
of the elevator
for devices under the
subcode/Elevat
or
elevator subcode
for devices
under the
elevator
subcode |
- |
pdf_text |
| 3001.4 |
3001.4
Building/Elevat
or
Elevator |
- |
pdf_text |
| 3001.4 |
3001.4
Building/Elevat
or
Elevator |
- |
pdf_text |
| 3001.5 |
3001.5
Building/Elevat
or
Elevator |
- |
pdf_text |
| 3001.5 |
3001.5
Building/Elevat
or
Elevator |
- |
pdf_text |
| 3001.6 |
3001.6
Building/Elevat
or
Building |
- |
pdf_text |
| 3002.1 |
3002.1
Building/Elevat
or/Fire
Building |
- |
pdf_text |
| 3002.1 |
3002.1
Building/Elevat
or/Fire
Building |
- |
pdf_text |
| 3002.2 |
3002.2
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 3002.2 |
3002.2
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 3002.3 |
3002.3
Building/Elevat
or
Elevator |
- |
pdf_text |
| 3002.3 |
3002.3
Building/Elevat
or
Elevator |
- |
pdf_text |
| 3002.4-3002.8 |
3002.4-3002.8
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 3002.4-3002.8 |
3002.4-3002.8
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 3002.9 |
3002.9
Plumbing/Eleva
tor
Plumbing for the piping
and discharge from the
pit/Elevator for the
presence of the drain |
- |
pdf_text |
| 3002.9 |
3002.9
Plumbing/Eleva
tor
Plumbing for the piping
and discharge from the
pit/Elevator for the presence
of the drain |
- |
pdf_text |
| 3003.1 |
3003.1
Building/Electri
cal/
Elevator
Elevator |
- |
pdf_text |
| 3003.1 |
3003.1
Building/Electri
cal/
Elevator
Elevator |
- |
pdf_text |
| 3003.2 |
3003.2
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 3003.2 |
3003.2
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 3003.3 |
3003.3
Elevator
Elevator |
- |
pdf_text |
| 3003.3 |
3003.3
Elevator
Elevator |
- |
pdf_text |
| 3004.1 |
3004.1
Building/Fire
Building for devices not
for devices not
under the scope of the |
- |
pdf_text |
| 3004.1 |
3004.1
Building/Fire
Building for devices not
for devices not
under the scope of the
under the scope
elevator subcode/Elevator
of the elevator
for devices under the
subcode/Elevat
or
elevator subcode
for devices
under the
elevator
subcode |
- |
pdf_text |
| 3004.2 |
3004.2
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 3004.2 |
3004.2
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 3004.2.1 |
3004.2.1
Building/Elevat
or/Fire
Building |
- |
pdf_text |
| 3004.2.1 |
3004.2.1
Building/Elevat
or/Fire
Building |
- |
pdf_text |
| 3004.2.2 |
3004.2.2
Elevator
Elevator |
- |
pdf_text |
| 3004.2.2 |
3004.2.2
Elevator
Elevator |
- |
pdf_text |
| 3004.3-3004.4 |
3004.3-3004.4
Building/Fire
Building |
- |
pdf_text |
| 3004.3-3004.4 |
3004.3-3004.4
Building/Fire
Building |
- |
pdf_text |
| 3005.1 |
3005.1
Building/Elevat
or/Fire
Building |
- |
pdf_text |
| 3005.1 |
3005.1
Building/Elevat
or/Fire
Building |
- |
pdf_text |
| 3005.2 |
3005.2
Building/Elevat
or
Elevator |
- |
pdf_text |
| 3005.2 |
3005.2
Building/Elevat
or
Elevator |
- |
pdf_text |
| 3005.3 |
3005.3
Elevator/Fire
Fire |
- |
pdf_text |
| 3005.3 |
3005.3
Elevator/Fire
Fire |
- |
pdf_text |
| 3005.4 |
3005.4
Building/Elevat
or
Building |
- |
pdf_text |
| 3005.4 |
3005.4
Building/Elevat
or
Building |
- |
pdf_text |
| 3005.5 |
3005.5
Fire/Electrical/
Elevator
Elevator |
- |
pdf_text |
| 3005.5 |
3005.5
Fire/Electrical/
Elevator
Elevator |
- |
pdf_text |
| 3005.6 |
3005.6
Elevator/Plumb
ing
Elevator |
- |
pdf_text |
| 3005.6 |
3005.6
Elevator/Plumb
ing
Elevator |
- |
pdf_text |
| 3006.1-3006.4 |
3006.1-3006.4
Building/Fire
Building |
- |
pdf_text |
| 3006.1-3006.4 |
3006.1-3006.4
Building/Fire
Building |
- |
pdf_text |
| 3007.1 |
3007.1
Elevator/Fire
Elevator |
- |
pdf_text |
| 3007.1 |
3007.1
Elevator/Fire
Elevator |
- |
pdf_text |
| 3007.2 |
3007.2
Fire
Fire |
- |
pdf_text |
| 3007.2 |
3007.2
Fire
Fire |
- |
pdf_text |
| 3007.3 |
3007.3
Building/Elevat
or
Building |
- |
pdf_text |
| 3007.3 |
3007.3
Building/Elevat
or
Building |
- |
pdf_text |
| 3007.4 |
3007.4
Elevator/Fire
Elevator |
- |
pdf_text |
| 3007.4 |
3007.4
Elevator/Fire
Elevator |
- |
pdf_text |
| 3007.5-3007.5.1 |
3007.5-3007.5.1
Building/Fire
Building |
- |
pdf_text |
| 3007.5-3007.5.1 |
3007.5-3007.5.1
Building/Fire
Building |
- |
pdf_text |
| 3007.5.2 |
3007.5.2
Building/Electri
cal/
Electrical for wiring and
Elevator/Fire
function/Elevator for
placement |
- |
pdf_text |
| 3007.5.2 |
3007.5.2
Building/Electri
cal/
Electrical for wiring and
Elevator/Fire
function/Elevator for
placement |
- |
pdf_text |
| 3007.6-3007.6.4 |
3007.6-3007.6.4
Building/Fire
Building |
- |
pdf_text |
| 3007.6-3007.6.4 |
3007.6-3007.6.4
Building/Fire
Building |
- |
pdf_text |
| 3007.6.5 |
3007.6.5
Elevator/Fire
Elevator |
- |
pdf_text |
| 3007.6.5 |
3007.6.5
Elevator/Fire
Elevator |
- |
pdf_text |
| 3007.7 |
3007.7
Elevator/Fire
Fire |
- |
pdf_text |
| 3007.7 |
3007.7
Elevator/Fire
Fire |
- |
pdf_text |
| 3007.8 |
3007.8
Electrical
Electrical |
- |
pdf_text |
| 3007.8 |
3007.8
Electrical
Electrical |
- |
pdf_text |
| 3007.8.1 |
3007.8.1
Building/Electri
cal
Electrical |
- |
pdf_text |
| 3007.8.1 |
3007.8.1
Building/Electri
cal
Electrical |
- |
pdf_text |
| 3007.9 |
3007.9
Fire
Fire |
- |
pdf_text |
| 3007.9 |
3007.9
Fire
Fire |
- |
pdf_text |
| 3008.1-3008.1.2 |
3008.1-3008.1.2
Building/Fire
Building |
- |
pdf_text |
| 3008.1-3008.1.2 |
3008.1-3008.1.2
Building/Fire
Building |
- |
pdf_text |
| 3008.1.3 |
3008.1.3
Fire
Fire |
- |
pdf_text |
| 3008.1.3 |
3008.1.3
Fire
Fire |
- |
pdf_text |
| 3008.1.4 |
3008.1.4
Elevator/Fire
Elevator |
- |
pdf_text |
| 3008.1.4 |
3008.1.4
Elevator/Fire
Elevator |
- |
pdf_text |
| 3008.10 |
3008.10
Building/Fire
Building
Ch. |
- |
pdf_text |
| 3008.10 |
3008.10
Building/Fire
Building
C
h.
Special Construction |
- |
pdf_text |
| 3008.2-3008.2.2 |
3008.2-3008.2.2
Fire
Fire |
- |
pdf_text |
| 3008.2-3008.2.2 |
3008.2-3008.2.2
Fire
Fire |
- |
pdf_text |
| 3008.3 |
3008.3
Building/Elevat
or
Building |
- |
pdf_text |
| 3008.3 |
3008.3
Building/Elevat
or
Building |
- |
pdf_text |
| 3008.4 |
3008.4
Elevator/Fire
Elevator |
- |
pdf_text |
| 3008.4 |
3008.4
Elevator/Fire
Elevator |
- |
pdf_text |
| 3008.5-3008.6.5 |
3008.5-3008.6.5
Building/Fire
Building |
- |
pdf_text |
| 3008.5-3008.6.5 |
3008.5-3008.6.5
Building/Fire
Building |
- |
pdf_text |
| 3008.6.6 |
3008.6.6
Fire
Fire |
- |
pdf_text |
| 3008.6.6 |
3008.6.6
Fire
Fire |
- |
pdf_text |
| 3008.7 |
3008.7
Elevator/Fire
Fire |
- |
pdf_text |
| 3008.7 |
3008.7
Elevator/Fire
Fire |
- |
pdf_text |
| 3008.8 |
3008.8
Electrical
Electrical |
- |
pdf_text |
| 3008.8 |
3008.8
Electrical
Electrical |
- |
pdf_text |
| 3008.8.1-3008.8.2 |
3008.8.1-3008.8.2
Building/Electri
Electrical |
- |
pdf_text |
| 3008.8.1-3008.8.2 |
3008.8.1-3008.8.2
Building/Electri
cal
Electrical |
- |
pdf_text |
| 3008.9 |
3008.9
Fire
Fire |
- |
pdf_text |
| 3008.9 |
3008.9
Fire
Fire |
- |
pdf_text |
| 301.1 |
301.1
Fire
Fire |
- |
pdf_text |
| 301.1 |
301.1
Fire
Fire |
- |
pdf_text |
| 301.1-308.3.2 |
301.1-308.3.2
Building
Building |
- |
pdf_text |
| 301.10 |
301.10
Electrical
Electrical |
- |
pdf_text |
| 301.10 |
301.10
Electrical
Electrical |
- |
pdf_text |
| 301.11 |
301.11
Plumbing
Plumbing |
- |
pdf_text |
| 301.11 |
301.11
Plumbing
Plumbing |
- |
pdf_text |
| 301.11 |
301.11
Building, except as
Building, except as
applicable based on
applicable based on
equipment
equipment |
- |
pdf_text |
| 301.12 |
301.12
Fire
Fire |
- |
pdf_text |
| 301.12 |
301.12
Fire
Fire |
- |
pdf_text |
| 301.12 |
301.12
Building
Building |
- |
pdf_text |
| 301.13 |
301.13
Building/Fire
Building |
- |
pdf_text |
| 301.13 |
301.13
Buildin
g/Fire
Building |
- |
pdf_text |
| 301.13-301.15 |
301.13-301.15
Building
Building |
- |
pdf_text |
| 301.13-301.18 |
301.13-301.18
Building
Building |
- |
pdf_text |
| 301.14-301.15 |
301.14-301.15
Buildin
g
Building |
- |
pdf_text |
| 301.14-301.15 |
301.14-301.15
Building
Building |
- |
pdf_text |
| 301.16 |
301.16
Building, except
Building, except
as applicable based
as applicable based
on equipment
on equipment |
- |
pdf_text |
| 301.17-301.18 |
301.17-301.18
Building
Building |
- |
pdf_text |
| 301.19 |
301.19
Electrical
Electrical
(switch)/Plumbing
(switch)/Plumbing
(valve)
(valve) |
- |
pdf_text |
| 301.19 |
301.19
Electrical
Electrical
(switch)/Plumbing
(switch)/Plumbing
(valve)
(valve) |
- |
pdf_text |
| 301.2 |
301.2
Building
Building |
- |
pdf_text |
| 301.2 |
301.2
Buildin
g
Building |
- |
pdf_text |
| 301.2 |
301.2
Building
Building |
- |
pdf_text |
| 301.3-301.5 |
301.3-301.5
Fire
Fire |
- |
pdf_text |
| 301.3-301.5 |
301.3-301.5
Plumbing
Plumbing |
- |
pdf_text |
| 301.3-301.5 |
301.3-301.5
Plumbing
Plumbing |
- |
pdf_text |
| 301.3-301.5 |
301.3-301.5
Fire
Fire |
- |
pdf_text |
| 301.6 |
301.6
Fire/Plumbing for
Fire/Plumbing for
fuel gas piping
fuel gas piping |
- |
pdf_text |
| 301.6 |
301.6
Fire/Plumbing for
Fire/Plumbing for |
- |
pdf_text |
| 301.6-301.7 |
301.6-301.7
Plumbi
ng
Plumbing |
- |
pdf_text |
| 301.6-301.7 |
301.6-301.7
Plumbing
Plumbing |
- |
pdf_text |
| 301.7-301.9 |
301.7-301.9
Fire
Fire |
- |
pdf_text |
| 301.7-301.9 |
301.7-301.9
Fire
Fire |
- |
pdf_text |
| 301.8-301.10 |
301.8-301.10
Building
Building |
- |
pdf_text |
| 301.8-301.12 |
301.8-301.12
Buildin
g
Building |
- |
pdf_text |
| 302 |
302
Buildin
g
Building |
- |
pdf_text |
| 302 |
302
Building
Building |
- |
pdf_text |
| 302 |
302
Building
Building |
- |
pdf_text |
| 302.4.2 |
302.4.2 which shall be
Electrical)
R303-R306
Building
Building
R307.1
Plumbing
Plumbing
R307.2-R309.3
Building
Building
R309.4
Electrical
Electrical
R309.5
Fire
Fire
R310-R311
Building/Fire
Building
R312
Building/Fire
Building
<
R313
Fire< 2>
Fire< 2>
>
R314-R314.5
Fire
Fire
R314.6
Electrical/Fire
Electrical
R314.7-R315.5
Fire
Fire |
- |
pdf_text |
| 303 |
303
Plumbing
Plumbing |
- |
pdf_text |
| 303 |
303
Plumbi
ng
Plumbing |
- |
pdf_text |
| 303-304.10 |
303-304.10
Fire
Fire |
- |
pdf_text |
| 303-304.10 |
303-304.10
Fire
Fire |
- |
pdf_text |
| 304-305 |
304-305
Fire
Fire |
- |
pdf_text |
| 304-305 |
304-305
Fire
Fire |
- |
pdf_text |
| 304.11 |
304.11
Building/Fire
Building |
- |
pdf_text |
| 304.11 |
304.11
Building/Fire
Building |
- |
pdf_text |
| 304.12 |
304.12
Fire
Fire |
- |
pdf_text |
| 304.12 |
304.12
Fire
Fire |
- |
pdf_text |
| 305 |
305
safety covers pursuant
to Section 305.1,
Exception 1, which shall
be Electrical)
ISPSC, Section
Plumbing
Plumbing |
- |
pdf_text |
| 305 |
305
Plumbing
Plumbing |
- |
pdf_text |
| 305 |
305
safety covers pursuant
to Section 305.1,
Exception 1, which shall |
- |
pdf_text |
| 305 |
305
Plumbing
Plumbing |
- |
pdf_text |
| 306-306.3 |
306-306.3
Building
Building |
- |
pdf_text |
| 306-306.3 |
306-306.3
Buildin
g
Building |
- |
pdf_text |
| 306.1-306.3 |
306.1-306.3
Building
Building |
- |
pdf_text |
| 306.1-306.3 |
306.1-306.3
Building
Building |
- |
pdf_text |
| 306.3.1 |
306.3.1
Electrical
Electrical |
- |
pdf_text |
| 306.3.1 |
306.3.1
Electrical
Electrical |
- |
pdf_text |
| 306.3.1 |
306.3.1
Electric
al
Electrical |
- |
pdf_text |
| 306.4 |
306.4
Building
Building |
- |
pdf_text |
| 306.4 |
306.4
Building
Building |
- |
pdf_text |
| 306.4 |
306.4
Buildin
g
Building |
- |
pdf_text |
| 306.4.1 |
306.4.1
Electrical
Electrical |
- |
pdf_text |
| 306.4.1 |
306.4.1
Electric
al
Electrical |
- |
pdf_text |
| 306.4.1 |
306.4.1
Electrical
Electrical |
- |
pdf_text |
| 306.5-306.5.1 |
306.5-306.5.1
Buildin
g
Building |
- |
pdf_text |
| 306.5-306.5.1 |
306.5-306.5.1
Building
Building |
- |
pdf_text |
| 306.5-306.5.1 |
306.5-306.5.1
Building
Building |
- |
pdf_text |
| 306.5.2 |
306.5.2
Electrical
Electrical |
- |
pdf_text |
| 306.5.2 |
306.5.2
Electric
al
Electrical |
- |
pdf_text |
| 306.5.2 |
306.5.2
Electrical
Electrical |
- |
pdf_text |
| 306.6 |
306.6
Buildin
g/Fire
Building |
- |
pdf_text |
| 306.6 |
306.6
Building/Fire
Building |
- |
pdf_text |
| 307 |
307
Plumbing
Plumbing |
- |
pdf_text |
| 307 |
307
Plumbing
Plumbing |
- |
pdf_text |
| 307 |
307
Plumbi
ng
Plumbing |
- |
pdf_text |
| 307.1 |
307.1(1) and 307.1(2) of the building subcode unless separated from the occupied area
appropriate fire resistance rated construction as prescribed in the building subcode. |
- |
pdf_text |
| 307.1 |
307.1(2)" for "307.7(1) and 307.7(2)"; in (d)6i, substituted "1006" for "1003.2.11"; in (d)6ii, upda
N.J.A.C. reference; in (d)9i, substituted "one-story" for "one story"; in (d)9i and (d)9ii, deleted "
exterior wall fire resistance rating as specified in section 507.2 of the building subcode," followin
building"; in (d)9ii, substituted "two-story" for "two story"; in (d)10i, substituted "1016" for "100
in (d)10ii, substituted "1019.1 and 1019.2" for "1005.2.1 and 1005.2.2"; in (d)10iii, substituted "1
"1003.2.10"; in (d)10iv, substituted "1006" for "1003.2.11" and "(d)6" for "(d)5"; and in (d)10v,
substituted "1004" for "1003.2".
Amended by R.2009 d.126, effective April 20, 2009.
See: 41 N.J.R. 16(a), 41 N.J.R. 1725(a).
Added new (d)5 and (d)(6); recodified former (d)5 through (d)11 as (d)7 through (d)13; in (d)9v
substituted "(d)12vii" for "(d)10vii"; in (d)11iii, substituted "(d)11i and ii" for "(d)9i and ii"; in th
introductory paragraph of (d)12, substituted "(d)11i" for "(d)9i"; and in (d)12iv, substituted "(d)7"
"(d)5".
Amended by R.2010 d.291, effective December 20, 2010. |
- |
pdf_text |
| 308 |
308
Building/Fire
Fire |
- |
pdf_text |
| 308 |
308
Fire
Fire |
- |
pdf_text |
| 308 |
308
Fire
Fire |
- |
pdf_text |
| 308 |
308
Building/Fire
Fire |
- |
pdf_text |
| 309 |
309
As applicable
As applicable |
- |
pdf_text |
| 309 |
309
Building
Building |
- |
pdf_text |
| 309 |
309
Electric
al
Electrical |
- |
pdf_text |
| 309 |
309
Building
Building |
- |
pdf_text |
| 309 |
309
Electrical
Electrical |
- |
pdf_text |
| 31 |
31. Delete section 1105, entitled "Type C (Visitable) Units" in its entirety.
v. Section 1103.2.3, Detached dwellings, shall be deleted and the following shall
inserted:
"1103.2.3 Residential buildings or structures. The following residential buildin
not required to comply with this chapter. |
- |
pdf_text |
| 31 |
31
Special Construction |
- |
pdf_text |
| 31 |
31. Delete section 1105, entitled "Type C (Visitable) Units" in its entirety.
iv. Section 1103.2.3, Detached dwellings, shall be deleted and the following shall
inserted:
"1103.2.3 Residential buildings or structures. The following residential buildi
not required to comply with this chapter. |
- |
pdf_text |
| 310 |
310
Plumbi
ng/
Plumbing-except when bonded to
Electric
al
electrical service equipment, then
Electrical
Ch. |
- |
pdf_text |
| 310 |
310 (APSP/ICC 7)
ISPSC, Section
Plumbing
Plumbing |
- |
pdf_text |
| 310 |
310
Plumbing/ Electrical
Plumbing-except when
bonded to electrical
service equipment, then
Electrical
Ch. |
- |
pdf_text |
| 310-311 |
310-311
Building/Fire
Fire |
- |
pdf_text |
| 310-311 |
310-311
Building/Fire
Fire |
- |
pdf_text |
| 3101-3102.3.1 |
3101-3102.3.1
Building
Building |
- |
pdf_text |
| 3101-3102.3.1 |
3101-3102.3.1
Building
Building |
- |
pdf_text |
| 3102.4-3102.6.1.1 |
3102.4-3102.6.1.1
Building/Fire
Building |
- |
pdf_text |
| 3102.4-3102.6.1.1 |
3102.4-3102.6.1.1
Building/Fire
Building |
- |
pdf_text |
| 3102.7-3102.8.1.2 |
3102.7-3102.8.1.2
Building
Building |
- |
pdf_text |
| 3102.7-3102.8.1.2 |
3102.7-3102.8.1.2
Building
Building |
- |
pdf_text |
| 3102.8.2 |
3102.8.2
Building/Electri
cal
Electrical |
- |
pdf_text |
| 3102.8.2 |
3102.8.2
Building/Electri
cal
Electrical |
- |
pdf_text |
| 3102.8.3-3103.2 |
3102.8.3-3103.2
Building
Building |
- |
pdf_text |
| 3102.8.3-3103.2 |
3102.8.3-3103.2
Building
Building |
- |
pdf_text |
| 3103.3-3104.10 |
3103.3-3104.10
Building/Fire
Building |
- |
pdf_text |
| 3103.3-3104.10 |
3103.3-3104.10
Building/Fire
Building |
- |
pdf_text |
| 3105.1 |
3105.1- 3108.2
Building
Building |
- |
pdf_text |
| 3105.1 |
3105.1- 3108.2
Building
Building |
- |
pdf_text |
| 3109 |
3109
See below for
ISPSC
See below for ISPSC
ISPSC, Section 305
Building
Building
(Except safety covers
pursuant to Section 305.1,
which shall be Electrical)
ISPSC, Section 310
Plumbing
Plumbing
(APSP/ICC 7)
ISPSC, Section 311.9
Plumbing
Plumbing
ISPSC, Section 324, except as
below
Building/Fire
Building
ISPSC, Section 324.2
Building/Fire
(except for
Building (except for the hose
the hose bibb
and
bibb and backflow preventer,
backflow
preventer,
which shall be plumbing)
which shall be
plumbing)
ISPSC, Section 324.4
Electrical
Electrical |
- |
pdf_text |
| 3109 |
3109
See below for
See below for ISPSC |
- |
pdf_text |
| 3109.2 |
3109.2 Amendments to the International Swimming Pool and Spa Code. The f
amendments shall be made to the International Swimming Pool and Spa Code: |
- |
pdf_text |
| 311 |
311 (APSP ICC/7)
ISPSC, Section
Plumbing
Plumbing |
- |
pdf_text |
| 311.9 |
311.9
ISPSC, Section
Building/Fire
Building |
- |
pdf_text |
| 3110 |
3110
Electrical
Electrical |
- |
pdf_text |
| 3110 |
3110
Electrical
Electrical |
- |
pdf_text |
| 3111.1 |
3111.1
Building
Building |
- |
pdf_text |
| 3111.1 |
3111.1
Building
Building |
- |
pdf_text |
| 3111.2 |
3111.2
Building/Fire/P
lumbing
Plumbing |
- |
pdf_text |
| 3111.2 |
3111.2
Building/Fire/P
lumbing
Plumbing |
- |
pdf_text |
| 3111.3.1 |
3111.3.1
Electrical
Electrical |
- |
pdf_text |
| 3111.3.1 |
3111.3.1
Electrical
Electrical |
- |
pdf_text |
| 3111.3.2 |
3111.3.2
Building
Building |
- |
pdf_text |
| 3111.3.2-3111.3.3 |
3111.3.2-3111.3.3
Building
Building |
- |
pdf_text |
| 3111.3.3 |
3111.3.3
Building
Building |
- |
pdf_text |
| 3111.3.4 |
3111.3.4
Electrical/Fire
Electrical |
- |
pdf_text |
| 3111.3.4 |
3111.3.4
Electrical/Fire
Electrical |
- |
pdf_text |
| 3111.3.5 |
3111.3.5
Building
Building |
- |
pdf_text |
| 3111.3.5 |
3111.3.5
Building/Fire
Building |
- |
pdf_text |
| 3111.3.6 |
3111.3.6
Building/Fire
Building |
- |
pdf_text |
| 3112 |
3112
Building
Building |
- |
pdf_text |
| 3112 |
3112
Building
Building |
- |
pdf_text |
| 3114 |
3114
Building
Building |
- |
pdf_text |
| 3115 |
3115
Building
Building
Ch. |
- |
pdf_text |
| 312 |
312
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 312 |
312
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 312.9 |
312.9
ISPSC, Section
Electrical
Electrical |
- |
pdf_text |
| 314.7 |
314.7
ISPSC, Section
Building/Fire
Building |
- |
pdf_text |
| 32 |
32
Encroachments into the
Building
Building
Public-Right-of-Way
Ch. |
- |
pdf_text |
| 32 |
32
Public-Right-of-Way
C
h.
Safeguards during |
- |
pdf_text |
| 324 |
324, except as
below
ISPSC, Section
Building/Fire (except for
Building (except for |
- |
pdf_text |
| 324.2 |
324.2
the hose bibb and backflow
the hose bibb and
preventer, which shall be
backflow preventer,
plumbing)
which shall be plumbing)
ISPC, Section
Electrical
Electrical |
- |
pdf_text |
| 324.4 |
324.4
R328.1-R328.6
Electrical
Electrical
R328.7-R328.8
Fire
Fire
R328.9
Electrical/Fire
Fire
R328.10-R328.11
Electrical
Electrical
R329
Electrical
Electrical
R330
Electrical/Fire
Fire
Ch.
Foundations
Building
Building |
- |
pdf_text |
| 325 |
325, except as
below
ISPSC, Section
Building/Fire (except
Building (except for |
- |
pdf_text |
| 325.2 |
325.2
for the hose bibb and
the hose bibb and
backflow preventer, which
backflow preventer,
shall be Plumbing)
which shall be Plumbing)
ISPC, Section
Electrical
Electrical |
- |
pdf_text |
| 325.4 |
325.4
R329.2
See Chapter 23
See Chapter 23
R329.3
Electrical
Electrical
R329.4-R329.5
Building
Building
R329.6
Electrical/Fire
Electrical
R329.7
Building
Building
R329.8
Building/Fire
Building
R330.1-R330.6
Electrical
Electrical
R330.7-R330.8
Fire
Fire
R330.9
Electrical/Fire
Fire |
- |
pdf_text |
| 33 |
33
Safeguards during
Construction |
- |
pdf_text |
| 3301 |
3301, except 3301.4
Building
Building |
- |
pdf_text |
| 3301 |
3301
Building
Building |
- |
pdf_text |
| 3301.4 |
3301.4
As applicable
As applicable |
- |
pdf_text |
| 3302 |
3302
Fire
Fire |
- |
pdf_text |
| 3302.1 |
3302.1
As applicable
As applicable |
- |
pdf_text |
| 3302.2 |
3302.2
Building
Building |
- |
pdf_text |
| 3302.3 |
3302.3
Fire
Fire |
- |
pdf_text |
| 3303.1-3303.5 |
3303.1-3303.5
Building
Building |
- |
pdf_text |
| 3303.1-3303.5 |
3303.1-3303.5
Building
Building |
- |
pdf_text |
| 3303.6 |
3303.6
As applicable
As applicable |
- |
pdf_text |
| 3303.6 |
3303.6
As applicable
As applicable |
- |
pdf_text |
| 3303.7 |
3303.7
Fire
Fire |
- |
pdf_text |
| 3303.7 |
3303.7
Fire
Fire |
- |
pdf_text |
| 3304-3308 |
3304-3308
Building
Building |
- |
pdf_text |
| 3304-3308 |
3304-3308
Building
Building |
- |
pdf_text |
| 3309 |
3309
Fire
Fire |
- |
pdf_text |
| 3309 |
3309
Fire
Fire |
- |
pdf_text |
| 3310 |
3310
Building/Fire
Building |
- |
pdf_text |
| 3310 |
3310
Building/Fire
Building |
- |
pdf_text |
| 3311-3313 |
3311-3313
Fire
Fire
App
x H
Signs
Building
Building except for H106
except for
H106
H106
Electrical
Electrical |
- |
pdf_text |
| 3311-3313 |
3311-3313
Fire
Fire
A
pp
x
Signs
Building
Building except for H106
H
except for
H106
H106
Electrical
Electrical |
- |
pdf_text |
| 36 |
36,000
(36,000
(18,000
per floor)
per floor) |
- |
pdf_text |
| 3D |
3D-Printed
Building
Building
AW
Building
Construction |
- |
pdf_text |
| 3D |
3D-Printed
Building
Building
BM
Building
Construction
App
x.
Extended Plate
Building
Building
BN
Wall Construction
App
x.
Solar-Ready
As applicable
As applicable
NB
Provisions--
Detached
One-and Two-
Family
Dwellings
App
x.
Zero Net Energy
As applicable
As applicable
NC
Residential
Building
Provisions |
- |
pdf_text |
| 4 |
4. Chapter 4, Commercial Energy Efficiency, shall be amended as follows:
i. At Section C401.2, Application, "Section C401.2.1 or" shall be deleted. In addit
Section C401.2.1, International Energy Conservation Code, shall be deleted in its
unless referenced for compliance in an optional appendix. Lastly, new Section C4
Amendments, shall be added as follows: The following amendments shall apply to
ASHRAE 90.1: |
- |
pdf_text |
| 4 |
4. Chapter 3 of the electrical subcode, entitled "Wiring Methods and Materials," is am
follows:
i. Section 300.4(A)(1) is amended to delete the words from "so that the edge. . ." o
four through ". . . cannot be maintained" on line six and in lieu thereof substitute "
required by the building subcode. Where the distance from the edge of the hole to t
nearest edge of the wood member is less than 32 mm (11/4 inches)."
ii. Section 334.12(A)(2) is deleted in its entirety. |
- |
pdf_text |
| 4 |
4. The use of standards of accepted practice. |
- |
pdf_text |
| 4 |
4
Special Detailed
Requirements Based on Use
and Occupancy |
- |
pdf_text |
| 4 |
4. Miscellaneous materials and supplies: |
- |
pdf_text |
| 4 |
4
Joints and Connections
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 4 |
4. Copies of the submitted applications for model code change proposals, transcripts
hearings on such applications, and State-sponsored model code change proposals, as a
shall be available from the Department at a fee of $.50 per page. |
- |
pdf_text |
| 4 |
4. Name of person or firm treating the material. |
- |
pdf_text |
| 4 |
4. Chapter 4, Commercial Energy Efficiency, shall be amended as follows:
i. In Section C401.2, Application, "Section C401.2.1 or" shall be deleted. In additi
Section C401.2.1, International Energy Conservation Code, shall be deleted in its
Lastly, new Section C401.2.2.1, Amendments, shall be added as follows: The follo
amendments shall apply to ASHRAE 90.1: |
- |
pdf_text |
| 4 |
4. Risers that are sized in accordance with the pipe schedule requirements |
- |
pdf_text |
| 4 |
4. Chapter 3 of the plumbing subcode, entitled "Materials," shall be amended as follo
i. In Section 3.1.1, Minimum Standards, delete "Minimum" in the title. In the sam
at items (1) and (2), delete "Section 3.12.2" and insert "N.J.A.C. 5:23-3.7."
ii. In Section 3.1.2, General Requirements, at Item a, delete "at least." In the same
delete "Section 3.12" and insert "N.J.A.C. 5:23-3.7."
iii. In Section 3.1.3, Standards Applicable to Plumbing Materials, "Section 3.12.2
deleted and "N.J.A.C. 5:23-3.7" shall be inserted.
iv. Section 3.3.11 entitled "Septic Tanks" is deleted in its entirety.
v. Add new Section 3.4.2.1 as follows: 3.4.2.1 Combination Domestic/Fire Water
Water service piping for combination domestic/fire water services shall be of mate
listed in Table 3.4 and shall be water pressure rated not less than 200 psig at 73° F.
restraints shall comply with Section 6.3, entitled "Joint Restraint for Fire Mains" p |
- |
pdf_text |
| 4 |
4. Chapter 4, Special Detailed Requirements Based on Use and Occupancy, shall be a
as follows:
i. In Section 402.8.3, Number of Means of Egress, "used by persons other than em
shall be deleted.
ii. In Section 406.3.2.1, Dwelling unit separation, the last sentence shall be delete
iii. In Section 407.2.6, Nursing home cooking facilities, in the title, add "and Assi
Living" after home.
iv. At Section 407.11, Electrical systems, "Chapter 27 and NFPA 99" shall be del
"the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
v. At Section 411.2, Automatic sprinkler system, the exception shall be deleted in
entirety.
vi. In Section 414.1.3, Information required, "building official" shall be deleted in
and third sentences and "fire protection subcode official" shall be inserted.
vii. Section 419, Artificial Decorative Vegetation, shall be deleted in its entirety.
viii. In Section 420, "I-2 Assisted Living" shall be inserted in the title.
(1) In Section 420.1, General, "I-2 Assisted living," shall be inserted after "I-1 |
- |
pdf_text |
| 4 |
4. Name of person or firm treating the material. |
- |
pdf_text |
| 4 |
4. Enforcing agency records: Such official(s) shall assist in the keeping of official rec
applications received, permits and certificates issued, fees collected, reports of inspect
notices and orders issued as may be required by the construction official.
History
HISTORY:
Amended by R.1998 d.28, effective January 5, 1998.
See: 29 New Jersey Register 3603(a), 30 New Jersey Register 129(a).
Amended by R.1999 d.424, effective December 6, 1999.
See: 31 New Jersey Register 2428(a), 31 New Jersey Register 4001(c).
In (a), deleted a reference to other State agencies in the introductory paragraph, and substituted a
reference to ordinary maintenance for a reference to ordinary repairs in 1.
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| 4 |
4. Chapter 3 of the plumbing subcode, entitled "Materials," shall be amended as follo
i. In Section 3.1.1, Minimum Standards, delete "Minimum" in the title. In the sam
at items (1) and (2), delete "Section 3.12.2" and insert "N.J.A.C. 5:23-3.7."
ii. In Section 3.1.2, General Requirements, at Item a, delete "at least." In the same
delete "Section 3.12" and insert "N.J.A.C. 5:23-3.7."
iii. In Section 3.1.3, Standards Applicable to Plumbing Materials, "Section 3.12.2
deleted and "N.J.A.C. 5:23-3.7" shall be inserted.
iv. In Table 3.1.3, Approved Materials, Part XI, Installation Procedures and Practi
insert: "11. Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Sp
Tubs, and Catch Basins: ANSI/APSN/ICC-7-2018."
v. Section 3.3.11 entitled "Septic Tanks" is deleted in its entirety.
vi. Add new section 3.4.2.1 as follows: 3.4.2.1 Combination Domestic/Fire Water
Water service piping for combination domestic/fire water services shall be of mate
listed in Table 3.4 and shall be water pressure rated not less than 200 psig at 73[de
Joint restraints shall comply with Section 6.3, entitled "Joint Restraint for Fire Mai
NFPA 13.
Exception: Limited area sprinkler systems installed in accordance with Section 9
the building subcode, shall be water pressure rated not less than 160 psig at 73[deg
vii. Section 3.12, Alternate Materials and Methods, shall be deleted in its entirety. |
- |
pdf_text |
| 4 |
4. Individual structures and dwelling units with truss construction that are part of a pl
real estate development shall not be required to have an identifying emblem if there is
emblem affixed at each entrance to the development.
(f) Swimming pools, spas and hot tubs: A valid electrical certificate of compliance and a
and grounding certificate shall be posted by the owner in a conspicuous place in or around
pump house or equipment control room.
History
HISTORY:
Amended by R.1989 d.555, effective November 6, 1989. |
- |
pdf_text |
| 4 |
4
Gas Piping
Plumbi
ng
Plumbing
Installation
Ch. |
- |
pdf_text |
| 4 |
4. Design minimum audibility level for occupant notification. |
- |
pdf_text |
| 4 |
4
Foundations
Building
Building
Ch. |
- |
pdf_text |
| 4 |
4. Energy Subcode:
International Energy Conservation Code--Residential
C
ha
pt
er
Section/Title
Responsibility
Plan Review
Inspection
C
h. |
- |
pdf_text |
| 4 |
4. Chapter 3 of the electrical subcode, entitled "Wiring Methods and Materials" is am
follows:
i. Section 300.4(A)(1) is amended to delete the words from "so that the edge. . ." o
four through ". . . cannot be maintained" on line six and in lieu thereof substitute "
required by the building subcode. Where the distance from the edge of the hole to t
nearest edge of the wood member is less than 32 mm (11/4 inches)." |
- |
pdf_text |
| 4 |
4
(R
E)
R401
Building
Building
R402 (except
Building
Building
R402.5.4-R402.5.5 and related
electrical items at Table
R402.5.1.1)
R402.5.4-R402.5.5 and related
Building/Electrical
Electrical
electrical items at Table
R402.5.1.1
R403.1
Electrical
Electrical
R403.2
Plumbing
Plumbing
R403.3
Building
Building
R403.4
Plumbing
Plumbing
R403.5.1, access
See R403.5.1.1
See R403.5.1.1
R403.5.1.1 -- Pump with
Plumbing
Plumbing
integrated switch
R403.5.1.1 -- Pump with
Electrical
Electrical
non-integrated switch
R403.5.1.2
Electrical
Electrical
R403.5.2- R403.5.3
Plumbing
Plumbing
R403.6
Building
Building
R403.7
Plumbing
Plumbing
R403.8
As applicable
As applicable
R403.9
Electrical
Electrical
R403.10.1 - Switch
Electrical
Electrical
R403.10.1 - Gas Heater, Pilot
Plumbing
Plumbing
R403.10.2-R403.12
Electrical
Electrical
R403.13
Plumbing
Plumbing
R404.1-R404.1.4
Electrical
Electrical
R404.1.5
Plumbing
Plumbing |
- |
pdf_text |
| 4 |
4
Administration and
As applicable
As applicable
Enforcement
Ch. |
- |
pdf_text |
| 4 |
4. Risers that are sized in accordance with the pipe schedule requireme
NFPA 14 listed in Chapter 35 are not subject to this requirement. |
- |
pdf_text |
| 4 |
4. Rehabilitation subcode code change proposals shall be submitted to the Code Deve
Unit, Department of Community Affairs, Division of Codes and Standards, PO Box 8
Trenton, New Jersey 08625. Code change proposals may be faxed to the Code Develo
Unit at (609) 633-6729. |
- |
pdf_text |
| 4 |
4. Chapter 4, Foundations, shall be amended as follows:
i. In Table R401.4.1, Presumptive Load Bearing Values of Foundation Materials, |
- |
pdf_text |
| 4 |
4. Septic tanks installed in compliance with rules adopted by DEP pursuant to P.L. 19
c.199 (N.J.S.A. 58:11-23 et seq.); |
- |
pdf_text |
| 4 |
4. A temporary greenhouse, also called a "hoophouse" or "polyhouse," used exclusive
the production and storage of live plants, shall be exempt from the permit requirement
Uniform Construction Code if it meets all the criteria of (d)4i through iii below:
i. There is no permanent anchoring system or foundation;
ii. There is no storage, temporary or otherwise, of solvents, fertilizers, gases, or ot
chemical or flammable materials; |
- |
pdf_text |
| 4 |
4. Class 1 and Class 2 structures where required in accordance with N.J.A.C. 5:23-4.3 |
- |
pdf_text |
| 4 |
4
Gas Piping
Plumbing
Plumbing
Installation
Ch. |
- |
pdf_text |
| 4 |
4. Chapter 4, Public swimming pools, shall be amended as follows: |
- |
pdf_text |
| 4 |
4
Ch.
Floors
Building
Building |
- |
pdf_text |
| 4 |
4
Ventilation
Building
Building
Ch. |
- |
pdf_text |
| 4 |
4
Joints and Connections
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 4 |
4. The distance from the outlet of the water closet to the connectio
wet vent is within the limits established by Section 12.8.4. Otherwi
water closet shall be individually vented. |
- |
pdf_text |
| 4 |
4. Chapter 4, Foundations, shall be amended as follows:
i. At Table R401.4.1(1), Presumptive Load Bearing Values of Foundation Materia
"12,000; 4,000; 3,000; 2,000; and 1,500" shall be deleted and "12,000; 6,000; 5,00
and 2,000" shall be inserted.
ii. Section R403.1.4, Minimum depth, shall have the following exceptions added:
"Exceptions: |
- |
pdf_text |
| 4 |
4. Under the heading of "Wind Design--Special wind region," insert "N/A" for
Applicable; |
- |
pdf_text |
| 4 |
4
Ventilation
Building
Building
Ch. |
- |
pdf_text |
| 4 |
4. Chapter 5 of the mechanical subcode, entitled "Exhaust Systems," shall be amende
follows: |
- |
pdf_text |
| 4 |
4
Residential Energy Efficiency
(R
E)
R401
Building
Building
R402 (except
Building
Building
R402.4.5-R402.4.6)
R402.4.5-R402.4.6
Electrical
Electrical
R403.1
Electrical
Electrical
R403.2
Plumbing
Plumbing
R403.3
Building
Building
R403.4
Plumbing
Plumbing
R403.5.1.1 -- Pump with
Plumbing
Plumbing
integrated switch
R403.5.1.1 -- Pump with
Electrical
Electrical
non-integrated switch
R403.5.1.2
Electrical
Electrical
R403.5.2- R403.5.3
Plumbing
Plumbing
R403.6
Building
Building
R403.7
Plumbing
Plumbing
R403.8
As applicable
As applicable
R403.9
Electrical
Electrical |
- |
pdf_text |
| 4 |
4. Chapter 4 of the fuel gas subcode, entitled "Gas Piping Installation," shall be amen
follows:
i. Section 401.2, Liquefied petroleum gas storage, shall be amended to add the fol
Notwithstanding the provisions contained in NFPA 58, the installation of LP-Gas
containers on roofs of buildings shall be strictly prohibited.
ii. Add new Section 401.11 as follows:
"401.11 Protection from vehicle impact. Gas meters, related regulators and pip
are installed indoors or outdoors and are subject to vehicle impact shall be prot
barriers meeting the requirements of Section 312 of the International Fire Code
purpose of applying this provision, "subject to vehicle impact" shall mean loca
within three feet of any garage door opening, driveway or designated parking a
not separated by a building wall from the space where a vehicle may be operat
(1) Exception: If verification of the installation of an excess flow valve is
by the gas utility, vehicle impact barriers shall not be required."
iii. In Section 402.7.1, Operation below -5[degrees]F (-21[degrees]C), insert the f
at the beginning of the section: "The operating pressure for undiluted LP-gas syste
not exceed 20 psig (140 kPa gauge)."
iv. Section 412, Liquefied petroleum gas motor vehicle fuel-dispensing facilities,
deleted. |
- |
pdf_text |
| 4 |
4. Chapter 4 of the fuel gas subcode, entitled "Gas Piping Installation," shall be amen
follows:
i. Section 401.2, Liquefied petroleum gas storage, shall be amended to add the fol
Notwithstanding the provisions contained in NFPA 58, the installation of LP-Gas
containers on roofs of buildings shall be strictly prohibited.
ii. Add new Section 401.11 as follows:
"401.11 Protection from vehicle impact. Gas meters, related regulators and pi
are installed indoors or outdoors and are subject to vehicle impact shall be prot
barriers meeting the requirements of Section 312 of the International Fire Code
purpose of applying this provision, "subject to vehicle impact" shall mean loca
within three feet of any garage door opening, driveway or designated parking a
not separated by a building wall from the space where a vehicle may be operat
(1) Exception: If verification of the installation of an excess flow valve is
by the gas utility, vehicle impact barriers shall not be required."
iii. In Section 402.7.1, Operation below -5[degrees]F (-21[degrees]C), insert the f
at the beginning of the section: "The operating pressure for undiluted LP-gas syste
not exceed 20 psig (140 kPa gauge)."
iv. Section 412, Liquefied petroleum gas motor vehicle fuel-dispensing facilities,
deleted. |
- |
pdf_text |
| 4 |
4. Energy Subcode:
International Energy Conservation Code--Residential
C
ha
pt
er
Section/Title
Responsibility
Inspection
Plan Review
C
h. |
- |
pdf_text |
| 4 |
4. The municipal code enforcing agency within the jurisdiction in which the facility is
shall be responsible for construction permit issuance, construction inspection and certi
occupancy issuance. |
- |
pdf_text |
| 4 |
4. Chapter 4, Special Detailed Requirements Based on Use and Occupancy, shall be a
as follows:
i. In Section 402.8.3, Number of Means of Egress, "used by persons other than em
shall be deleted.
ii. In Section 406.3.2.1, Dwelling unit separation, the last sentence shall be delete
iii. In Section 407.2.6, Nursing home cooking facilities, in the title, add "and Assi
Living" after home.
iv. In Section 407.11, Electrical systems, "Chapter 27" shall be deleted and "the el
subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
v. In Section 411.2, Automatic sprinklers, the exception shall be deleted in its enti
vi. In Section 414.1.3, Information required, "building official" shall be deleted in
and third sentences and "fire protection subcode official" shall be inserted.
vii. Section 419, Artificial Decorative Vegetation, shall be deleted in its entirety.
viii. In Section 420, "I-2 Assisted Living" shall be inserted in the title.
(1) In Section 420.1, General, "I-2 Assisted living," shall be inserted after "I-1
(2) In Section 420.4, Automatic sprinkler system, in the second sentence, "and
Assisted living" shall be inserted after "I-1."
(3) In Section 420.5, Fire alarm systems and smoke alarms, in the first sentenc
Assisted living," shall be inserted after "I-1," delete the second "and" and inser
between "R-1" and "R-2," insert "and R-4" after "R-2," delete the third "and" a
"," between "907.2.8" and "907.2.9" and insert "and 907.2.9A" after "907.2.9." |
- |
pdf_text |
| 4 |
4
Special Detailed
Requirements Based on Use
and Occupancy |
- |
pdf_text |
| 4 |
4. Liquefied petroleum gas installations, except vapor delivery installations utilizing
containers with an aggregate water capacity of 2,000 gallons or less, which jurisdictio
retained by the municipal enforcing agency.
(k) The Department shall be the sole enforcing agency for Cooperative Sober Living Resi
licensed as Class F rooming houses pursuant to N.J.A.C. 5:27.
(l) The Department shall be the sole enforcing agency for work relating to motion picture
television film sets, and motion picture and television film locations, including the constru |
- |
pdf_text |
| 4 |
4. Chapter 4, Public swimming pools, shall be amended as follows:
In Section 410.1, Toilet facilities, "International Building Code or Inter
Plumbing Code" shall be deleted and "plumbing subcode (N.J.A.C. 5:2
shall be inserted. |
- |
pdf_text |
| 4 |
4. Delete Chapter 2, "Scoping"; |
- |
pdf_text |
| 4 |
4,000; 3,000; 2,000; and 1,500" shall be deleted and "12,000; 6,000; 5,000; 3,000; |
- |
pdf_text |
| 4 |
4
Administration and
As applicable
As applicable
Enforcement
Ch. |
- |
pdf_text |
| 4 |
4. Enforcing agency records: Such official(s) shall assist in the keeping of official rec
applications received, permits and certificates issued, fees collected, reports of inspect
notices and orders issued as may be required by the construction official.
History
HISTORY:
Amended by R.1998 d.28, effective January 5, 1998.
See: 29 New Jersey Register 3603(a), 30 New Jersey Register 129(a).
Amended by R.1999 d.424, effective December 6, 1999.
See: 31 New Jersey Register 2428(a), 31 New Jersey Register 4001(c).
In (a), deleted a reference to other State agencies in the introductory paragraph, and substituted a
reference to ordinary maintenance for a reference to ordinary repairs in 1.
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| 4 |
4. Chapter 4, Residential Energy Efficiency, shall be amended as follows:
i. Section R401.2, Application, the exception shall be deleted in its entirety.
ii. In Section R403.7, Equipment sizing and efficiency rating (Mandatory), "or
replacement" shall be deleted in the second sentence. |
- |
pdf_text |
| 4 |
4. Chapter 4, Residential Energy Efficiency, shall be amended as follows:
i. Section R401.2, Application, the exception shall be deleted in its entirety.
ii. At Section R403.7, Equipment sizing and efficiency rating, "or replacement" sh
deleted in the second sentence.
iii. At Section R403.8, Systems serving multiple dwelling units, delete "Sections
C404 of the IECC--Commercial Provisions" and replace with "Chapters 6 and 7 of
ASHRAE Standard 90.1". |
- |
pdf_text |
| 4.1 |
4.1 In Section 410.1, Toilet facilities, "International Building Code or
International Plumbing Code" shall be deleted and "plumbing subcode
(N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 4.1 |
4.1 In Section 410.1, Toilet facilities, "International Building Code or
International Plumbing Code" shall be deleted and "plumbing subcode
(N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 4.1 |
4.1 At Section 410.1, Toilet facilities, "International Building Code or Inte
Plumbing Code" shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.
shall be inserted. |
- |
pdf_text |
| 400-450.28 |
400-450.28, except 450.21(B)
Electrical
Electrical |
- |
pdf_text |
| 400-450.28 |
400-450.28
Electrical
Electrical |
- |
pdf_text |
| 401.1-402.4 |
401.1-402.4
Building/Fire
Building |
- |
pdf_text |
| 401.1-402.4 |
401.1-402.4
Building/Fire
Building |
- |
pdf_text |
| 401.1-406.14 |
401.1-406.14
Building
Building |
- |
pdf_text |
| 402.5 |
402.5
Fire
Fire |
- |
pdf_text |
| 402.5 |
402.5
Fire
Fire |
- |
pdf_text |
| 402.6.1 |
402.6.1
Building/Fire
Building |
- |
pdf_text |
| 402.6.1 |
402.6.1
Building/Fire
Building |
- |
pdf_text |
| 402.6.2 |
402.6.2 #2
Fire
Fire |
- |
pdf_text |
| 402.6.2 |
402.6.2 #3-#4
Building
Building |
- |
pdf_text |
| 402.6.2 |
402.6.2 #3-#4
Building
Building |
- |
pdf_text |
| 402.6.2 |
402.6.2 #1
Building/Fire
Building |
- |
pdf_text |
| 402.6.2 |
402.6.2 #1
Building/Fire
Building |
- |
pdf_text |
| 402.6.2 |
402.6.2 #2
Fire
Fire |
- |
pdf_text |
| 402.6.3 |
402.6.3
Building
Building |
- |
pdf_text |
| 402.6.3 |
402.6.3
Building
Building |
- |
pdf_text |
| 402.6.4 |
402.6.4
Building/Fire
Building |
- |
pdf_text |
| 402.6.4 |
402.6.4
Building/Fire
Building |
- |
pdf_text |
| 402.7.1-402.7.2 |
402.7.1-402.7.2
Fire
Fire |
- |
pdf_text |
| 402.7.1-402.7.2 |
402.7.1-402.7.2
Fire
Fire |
- |
pdf_text |
| 402.7.3 |
402.7.3
Fire/Electrical
Electrical |
- |
pdf_text |
| 402.7.3 |
402.7.3
Fire/Electrical
Electrical |
- |
pdf_text |
| 402.7.4 |
402.7.4
Fire/Electrical
Fire |
- |
pdf_text |
| 402.7.4 |
402.7.4
Fire/Electrical
Fire |
- |
pdf_text |
| 402.7.5 |
402.7.5
Building/Fire
Fire |
- |
pdf_text |
| 402.7.5 |
402.7.5
Building/Fire
Fire |
- |
pdf_text |
| 402.8 |
402.8
Building/Fire
Building |
- |
pdf_text |
| 402.8 |
402.8
Building/Fire
Building |
- |
pdf_text |
| 403.1-403.2.1.2 |
403.1-403.2.1.2
Building/Fire
Building |
- |
pdf_text |
| 403.1-403.2.1.2 |
403.1-403.2.1.2
Building/Fire
Building |
- |
pdf_text |
| 403.2.2-403.2.3 |
403.2.2-403.2.3
Building
Building |
- |
pdf_text |
| 403.2.2-403.2.3 |
403.2.2-403.2.3
Building
Building |
- |
pdf_text |
| 403.3 |
403.3
Fire
Fire |
- |
pdf_text |
| 403.3 |
403.3
Fire
Fire |
- |
pdf_text |
| 403.4.1-403.4.7 |
403.4.1-403.4.7
Fire
Fire |
- |
pdf_text |
| 403.4.1-403.4.7 |
403.4.1-403.4.7
Fire
Fire |
- |
pdf_text |
| 403.4.8 |
403.4.8
Electrical/Fire
Fire |
- |
pdf_text |
| 403.4.8 |
403.4.8
Electrical/Fire
Fire |
- |
pdf_text |
| 403.4.8.1 |
403.4.8.1
Building/Fire
Building (except system
supervision location, which
is Fire) |
- |
pdf_text |
| 403.4.8.1 |
403.4.8.1
Building/Fire
Building (except system
supervision location, which
is Fire) |
- |
pdf_text |
| 403.4.8.2 |
403.4.8.2
Building/Fire
Building |
- |
pdf_text |
| 403.4.8.2 |
403.4.8.2
Building/Fire
Building |
- |
pdf_text |
| 403.4.8.3-403.4.8.4 |
403.4.8.3-403.4.8.4
Electrical/Fire
Electrical |
- |
pdf_text |
| 403.4.8.3-403.4.8.4 |
403.4.8.3-403.4.8.4
Electrical/Fire
Electrical |
- |
pdf_text |
| 403.5-403.5.2 |
403.5-403.5.2
Building/Fire
Building |
- |
pdf_text |
| 403.5-403.5.2 |
403.5-403.5.2
Building/Fire
Building |
- |
pdf_text |
| 403.5.3 |
403.5.3
Building/Fire
Fire |
- |
pdf_text |
| 403.5.3 |
403.5.3
Building/Fire
Fire |
- |
pdf_text |
| 403.5.4-403.5.5 |
403.5.4-403.5.5
Building/Fire
Building |
- |
pdf_text |
| 403.5.4-403.5.5 |
403.5.4-403.5.5
Building/Fire
Building |
- |
pdf_text |
| 403.6 |
403.6
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 403.6 |
403.6
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 403.6.1-403.6.2 |
403.6.1-403.6.2
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 403.6.1-403.6.2 |
403.6.1-403.6.2
Building/Elevat
or/Fire
Elevator |
- |
pdf_text |
| 404.1-404.2 |
404.1-404.2
Building/Fire
Building |
- |
pdf_text |
| 404.1-404.2 |
404.1-404.2
Building/Fire
Building |
- |
pdf_text |
| 404.3-404.5 |
404.3-404.5
Fire
Fire |
- |
pdf_text |
| 404.3-404.5 |
404.3-404.5
Fire
Fire |
- |
pdf_text |
| 404.6 |
404.6
Building/Fire
Building |
- |
pdf_text |
| 404.6 |
404.6
Building/Fire
Building |
- |
pdf_text |
| 404.7 |
404.7
Fire/Electrical
Electrical |
- |
pdf_text |
| 404.7 |
404.7
Fire/Electrical
Electrical |
- |
pdf_text |
| 404.8-404.11 |
404.8-404.11
Building/Fire
Building |
- |
pdf_text |
| 404.8-404.11 |
404.8-404.11
Building/Fire
Building |
- |
pdf_text |
| 405.1-405.2 |
405.1-405.2
Building/Fire
Building |
- |
pdf_text |
| 405.1-405.2 |
405.1-405.2
Building/Fire
Building |
- |
pdf_text |
| 405.3 |
405.3
Fire
Fire |
- |
pdf_text |
| 405.3 |
405.3
Fire
Fire |
- |
pdf_text |
| 405.4 |
405.4
Building/Fire
Building |
- |
pdf_text |
| 405.4 |
405.4
Building/Fire
Building |
- |
pdf_text |
| 405.5-405.6 |
405.5-405.6
Fire
Fire |
- |
pdf_text |
| 405.5-405.6 |
405.5-405.6
Fire
Fire |
- |
pdf_text |
| 405.7 |
405.7
Building/Fire
Building |
- |
pdf_text |
| 405.7 |
405.7
Building/Fire
Building |
- |
pdf_text |
| 405.8 |
405.8
Electrical
Electrical |
- |
pdf_text |
| 405.8 |
405.8
Electrical
Electrical |
- |
pdf_text |
| 405.9 |
405.9
Fire
Fire |
- |
pdf_text |
| 405.9 |
405.9
Fire
Fire |
- |
pdf_text |
| 406.1-406.2.6 |
406.1-406.2.6
Building/Fire
Building |
- |
pdf_text |
| 406.1-406.2.6 |
406.1-406.2.6
Building/Fire
Building |
- |
pdf_text |
| 406.2.7 |
406.2.7
Building/Electri
cal
Electrical |
- |
pdf_text |
| 406.2.7 |
406.2.7
Building/Electri
cal
Electrical |
- |
pdf_text |
| 406.2.8 |
406.2.8
Building/Fire
Building |
- |
pdf_text |
| 406.2.8 |
406.2.8
Building/Fire
Building |
- |
pdf_text |
| 406.2.9 |
406.2.9
Fire
Fire |
- |
pdf_text |
| 406.2.9 |
406.2.9
Fire
Fire |
- |
pdf_text |
| 406.3-406.3.5 |
406.3-406.3.5
Building/Fire
Building |
- |
pdf_text |
| 406.3-406.3.5 |
406.3-406.3.5
Building/Fire
Building |
- |
pdf_text |
| 406.4-406.4.3 |
406.4-406.4.3
Building
Building |
- |
pdf_text |
| 406.4-406.4.3 |
406.4-406.4.3
Building
Building |
- |
pdf_text |
| 406.5.1 |
406.5.1
Building/Fire
Building |
- |
pdf_text |
| 406.5.1 |
406.5.1
Building/Fire
Building |
- |
pdf_text |
| 406.5.10 |
406.5.10
Building
Building |
- |
pdf_text |
| 406.5.10 |
406.5.10
Building
Building |
- |
pdf_text |
| 406.5.11-406.6.1 |
406.5.11-406.6.1
Building/Fire
Building |
- |
pdf_text |
| 406.5.11-406.6.1 |
406.5.11-406.6.1
Building/Fire
Building |
- |
pdf_text |
| 406.5.2 |
406.5.2
Building
Building |
- |
pdf_text |
| 406.5.2 |
406.5.2
Building
Building |
- |
pdf_text |
| 406.5.3-406.5.7 |
406.5.3-406.5.7
Building/Fire
Building |
- |
pdf_text |
| 406.5.3-406.5.7 |
406.5.3-406.5.7
Building/Fire
Building |
- |
pdf_text |
| 406.5.8 |
406.5.8
Fire
Fire |
- |
pdf_text |
| 406.5.8 |
406.5.8
Fire
Fire |
- |
pdf_text |
| 406.5.9 |
406.5.9
Building/Fire
Building |
- |
pdf_text |
| 406.5.9 |
406.5.9
Building/Fire
Building |
- |
pdf_text |
| 406.6.2 |
406.6.2
Building
Building |
- |
pdf_text |
| 406.6.2 |
406.6.2
Building
Building |
- |
pdf_text |
| 406.6.3-406.6.4 |
406.6.3-406.6.4
Fire
Fire |
- |
pdf_text |
| 406.6.3-406.6.4 |
406.6.3-406.6.4
Fire
Fire |
- |
pdf_text |
| 406.6.4.1 |
406.6.4.1
Building/Fire
Building |
- |
pdf_text |
| 406.6.4.1 |
406.6.4.1
Building/Fire
Building |
- |
pdf_text |
| 406.6.4.2-406.7 |
406.6.4.2-406.7
Fire
Fire |
- |
pdf_text |
| 406.6.4.2-406.7 |
406.6.4.2-406.7
Fire
Fire |
- |
pdf_text |
| 406.7.1 |
406.7.1
Electrical
Electrical |
- |
pdf_text |
| 406.7.1 |
406.7.1
Electrical
Electrical |
- |
pdf_text |
| 406.7.2-406.8 |
406.7.2-406.8
Building/Fire
Building |
- |
pdf_text |
| 406.7.2-406.8 |
406.7.2-406.8
Building/Fire
Building |
- |
pdf_text |
| 406.8.1 |
406.8.1
Building
Building |
- |
pdf_text |
| 406.8.1 |
406.8.1
Building
Building |
- |
pdf_text |
| 406.8.2-406.8.3 |
406.8.2-406.8.3
Fire
Fire |
- |
pdf_text |
| 406.8.2-406.8.3 |
406.8.2-406.8.3
Fire
Fire |
- |
pdf_text |
| 407-410 |
407-410
Elevator
Elevator |
- |
pdf_text |
| 407.1-407.2.5 |
407.1-407.2.5
Building/Fire
Building |
- |
pdf_text |
| 407.1-407.2.5 |
407.1-407.2.5
Building/Fire
Building |
- |
pdf_text |
| 407.10 |
407.10
Building/Fire
Building |
- |
pdf_text |
| 407.10 |
407.10
Building/Fire
Building |
- |
pdf_text |
| 407.11 |
407.11
Electrical
Electrical |
- |
pdf_text |
| 407.11 |
407.11
Electrical
Electrical |
- |
pdf_text |
| 407.2.6-407.2.7 |
407.2.6-407.2.7
Fire
Fire |
- |
pdf_text |
| 407.2.6-407.2.7 |
407.2.6-407.2.7
Fire
Fire |
- |
pdf_text |
| 407.3-407.4.4.5 |
407.3-407.4.4.5#1 and
Building/Fire
Building
#2 |
- |
pdf_text |
| 407.3-407.4.4.6 |
407.3-407.4.4.6 #1 and
Building/Fire
Building
#2 |
- |
pdf_text |
| 407.4.4.5 |
407.4.4.5#3
Building/Fire
Fire |
- |
pdf_text |
| 407.4.4.5.1-407.6 |
407.4.4.5.1-407.6
Building/Fire
Building |
- |
pdf_text |
| 407.4.4.6 |
407.4.4.6 #3
Building/Fire
Fire |
- |
pdf_text |
| 407.4.4.6.1-407.6 |
407.4.4.6.1-407.6
Building/Fire
Building |
- |
pdf_text |
| 407.7-407.9 |
407.7-407.9
Fire
Fire |
- |
pdf_text |
| 407.7-407.9 |
407.7-407.9
Fire
Fire |
- |
pdf_text |
| 408.1-408.8.4 |
408.1-408.8.4
Building/Fire
Building |
- |
pdf_text |
| 408.1-408.8.4 |
408.1-408.8.4
Building/Fire
Building |
- |
pdf_text |
| 408.9-408.11 |
408.9-408.11
Fire
Fire |
- |
pdf_text |
| 408.9-408.11 |
408.9-408.11
Fire
Fire |
- |
pdf_text |
| 409-410.5.3.5 |
409-410.5.3.5
Building/Fire
Building |
- |
pdf_text |
| 409-410.5.3.5 |
409-410.5.3.5
Building/Fire
Building |
- |
pdf_text |
| 410.6 |
410.6
Fire
Fire |
- |
pdf_text |
| 410.6-410.7 |
410.6-410.7
Fire
Fire |
- |
pdf_text |
| 411.1 |
411.1
Building/Fire
Building |
- |
pdf_text |
| 411.1 |
411.1
Building/Fire
Building |
- |
pdf_text |
| 411.2-411.3.3 |
411.2-411.3.3
Fire
Fire |
- |
pdf_text |
| 411.2-411.4 |
411.2-411.4
Fire
Fire |
- |
pdf_text |
| 411.4-412.2.2.3.2 |
411.4-412.2.2.3.2
Building/Fire
Building |
- |
pdf_text |
| 411.5-412.2.2.3.2 |
411.5-412.2.2.3.2
Building/Fire
Building |
- |
pdf_text |
| 412.2.3-412.2.4 |
412.2.3-412.2.4
Fire
Fire |
- |
pdf_text |
| 412.2.3-412.2.4 |
412.2.3-412.2.4
Fire
Fire |
- |
pdf_text |
| 412.2.4.1 |
412.2.4.1
Building/Fire
Building |
- |
pdf_text |
| 412.2.4.1 |
412.2.4.1
Building/Fire
Building |
- |
pdf_text |
| 412.2.5 |
412.2.5
Building/Electri
cal
Building |
- |
pdf_text |
| 412.2.5 |
412.2.5
Building/Electri
cal
Building |
- |
pdf_text |
| 412.2.6 |
412.2.6
Building
Building |
- |
pdf_text |
| 412.2.6 |
412.2.6
Building
Building |
- |
pdf_text |
| 412.3-412.3.5 |
412.3-412.3.5
Building/Fire
Building |
- |
pdf_text |
| 412.3-412.3.5 |
412.3-412.3.5
Building/Fire
Building |
- |
pdf_text |
| 412.3.6-412.3.6.1 |
412.3.6-412.3.6.1
Fire
Fire |
- |
pdf_text |
| 412.3.6-412.3.6.1 |
412.3.6-412.3.6.1
Fire
Fire |
- |
pdf_text |
| 412.3.6.2-412.4.2 |
412.3.6.2-412.4.2
Building/Fire
Building |
- |
pdf_text |
| 412.3.6.2-412.4.2 |
412.3.6.2-412.4.2
Building/Fire
Building |
- |
pdf_text |
| 412.4.3 |
412.4.3
Fire
Fire |
- |
pdf_text |
| 412.4.3 |
412.4.3
Fire
Fire |
- |
pdf_text |
| 412.4.4 |
412.4.4
As
As appropriate
appropriate |
- |
pdf_text |
| 412.4.4 |
412.4.4
As
As appropriate
appropriate |
- |
pdf_text |
| 412.4.5-412.5.5 |
412.4.5-412.5.5
Building/Fire
Building |
- |
pdf_text |
| 412.4.5-412.5.5 |
412.4.5-412.5.5
Building/Fire
Building |
- |
pdf_text |
| 412.5.6 |
412.5.6
Fire
Fire |
- |
pdf_text |
| 412.5.6 |
412.5.6
Fire
Fire |
- |
pdf_text |
| 412.5.7 |
412.5.7
Building/Fire
Building |
- |
pdf_text |
| 412.5.7 |
412.5.7
Building/Fire
Building |
- |
pdf_text |
| 412.5.8 |
412.5.8
Electrical
Electrical |
- |
pdf_text |
| 412.5.8 |
412.5.8
Electrical
Electrical |
- |
pdf_text |
| 412.6-412.7.3 |
412.6-412.7.3
Building/Fire
Building |
- |
pdf_text |
| 412.6-412.7.3 |
412.6-412.7.3
Building/Fire
Building |
- |
pdf_text |
| 412.7.4 |
412.7.4
Building/Fire
Fire |
- |
pdf_text |
| 412.7.4 |
412.7.4
Building/Fire
Fire |
- |
pdf_text |
| 412.7.5 |
412.7.5
Fire
Fire |
- |
pdf_text |
| 412.7.5 |
412.7.5
Fire
Fire |
- |
pdf_text |
| 413.1 |
413.1
Fire
Fire |
- |
pdf_text |
| 413.1 |
413.1
Fire
Fire |
- |
pdf_text |
| 413.2 |
413.2
Building/Fire
Building |
- |
pdf_text |
| 413.2 |
413.2
Building/Fire
Building |
- |
pdf_text |
| 414.1-414.2 |
414.1-414.2
Building/Fire
Fire |
- |
pdf_text |
| 414.1-414.2 |
414.1-414.2
Building/Fire
Fire |
- |
pdf_text |
| 414.2.1 |
414.2.1
Building/Fire
Building |
- |
pdf_text |
| 414.2.1 |
414.2.1
Building/Fire
Building |
- |
pdf_text |
| 414.2.2-414.2.3 |
414.2.2-414.2.3
Building/Fire
Fire |
- |
pdf_text |
| 414.2.2-414.2.3 |
414.2.2-414.2.3
Building/Fire
Fire |
- |
pdf_text |
| 414.2.4 |
414.2.4
Building/Fire
Building |
- |
pdf_text |
| 414.2.4 |
414.2.4
Building/Fire
Building |
- |
pdf_text |
| 414.2.5-414.5.1 |
414.2.5-414.5.1
Building/Fire
Fire |
- |
pdf_text |
| 414.2.5-414.5.1 |
414.2.5-414.5.1
Building/Fire
Fire |
- |
pdf_text |
| 414.5.2 |
414.5.2
Electrical
Electrical |
- |
pdf_text |
| 414.5.2 |
414.5.2
Electrical
Electrical |
- |
pdf_text |
| 414.5.3 |
414.5.3
Building/Fire
Fire |
- |
pdf_text |
| 414.5.3 |
414.5.3
Building/Fire
Fire |
- |
pdf_text |
| 414.6 |
414.6
Building/Fire
Building |
- |
pdf_text |
| 414.6 |
414.6
Building/Fire
Fire |
- |
pdf_text |
| 415.1-415.2 |
415.1-415.2
Building/Fire
Building |
- |
pdf_text |
| 415.1-415.2 |
415.1-415.2
Building/Fire
Building |
- |
pdf_text |
| 415.10.2-415.10.4 |
415.10.2-415.10.4
Building/Fire
Building |
- |
pdf_text |
| 415.10.2-415.10.4 |
415.10.2-415.10.4
Building/Fire
Building |
- |
pdf_text |
| 415.11.1-415.11.1.1 |
415.11.1-415.11.1.1
Building/Fire
Fire |
- |
pdf_text |
| 415.11.1-415.11.1.1.2 |
415.11.1-415.11.1.1.2
Building/Fire
Fire |
- |
pdf_text |
| 415.11.1.2-415.11.1.7 |
415.11.1.2-415.11.1.7
Building/Fire
Building |
- |
pdf_text |
| 415.11.1.2-415.11.1.7 |
415.11.1.2-415.11.1.7
Building/Fire
Building |
- |
pdf_text |
| 415.11.1.8 |
415.11.1.8
Electrical/Fire
Electrical |
- |
pdf_text |
| 415.11.1.8 |
415.11.1.8
Electrical/Fire
Electrical |
- |
pdf_text |
| 415.11.1.8.1-415.11.3.4 |
415.11.1.8.1-415.11.3.4
Building/Fire
Building |
- |
pdf_text |
| 415.11.1.8.1-415.11.3.4 |
415.11.1.8.1-415.11.3.4
Building/Fire
Building |
- |
pdf_text |
| 415.11.11-415.11.11.2 |
415.11.11-415.11.11.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 415.11.11-415.11.11.2 |
415.11.11-415.11.11.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 415.11.12-415.11.12.3 |
415.11.12-415.11.12.3
Fire
Fire |
- |
pdf_text |
| 415.11.12-415.11.12.3 |
415.11.12-415.11.12.3
Fire
Fire |
- |
pdf_text |
| 415.11.4-415.11.5 |
415.11.4-415.11.5
Fire
Fire |
- |
pdf_text |
| 415.11.4-415.11.5 |
415.11.4-415.11.5
Fire
Fire |
- |
pdf_text |
| 415.11.6-415.11.6.4 |
415.11.6-415.11.6.4
Building/Fire
Building/Fire |
- |
pdf_text |
| 415.11.6-415.11.6.4 |
415.11.6-415.11.6.4
Building/Fire
Building/Fire |
- |
pdf_text |
| 415.11.6.5 |
415.11.6.5
Fire
Fire |
- |
pdf_text |
| 415.11.6.5 |
415.11.6.5
Fire
Fire |
- |
pdf_text |
| 415.11.6.6-415.11.6.8 |
415.11.6.6-415.11.6.8
Building/Fire
Building |
- |
pdf_text |
| 415.11.6.6-415.11.6.8 |
415.11.6.6-415.11.6.8
Building/Fire
Building |
- |
pdf_text |
| 415.11.6.9 |
415.11.6.9
Fire
Fire |
- |
pdf_text |
| 415.11.6.9 |
415.11.6.9
Fire
Fire |
- |
pdf_text |
| 415.11.7-415.11.7.2 |
415.11.7-415.11.7.2
Building/Fire
Building |
- |
pdf_text |
| 415.11.7-415.11.7.2 |
415.11.7-415.11.7.2
Building/Fire
Building |
- |
pdf_text |
| 415.11.7.3 |
415.11.7.3
Building/Fire
Fire |
- |
pdf_text |
| 415.11.7.3 |
415.11.7.3
Building/Fire
Fire |
- |
pdf_text |
| 415.11.7.4 |
415.11.7.4
Building/Fire
Building |
- |
pdf_text |
| 415.11.7.4 |
415.11.7.4
Building/Fire
Building |
- |
pdf_text |
| 415.11.7.5-415.11.10.3 |
415.11.7.5-415.11.10.3
Fire
Fire |
- |
pdf_text |
| 415.11.7.5-415.11.10.3 |
415.11.7.5-415.11.10.3
Fire
Fire |
- |
pdf_text |
| 415.3-415.5 |
415.3-415.5
Fire
Fire |
- |
pdf_text |
| 415.3-415.5 |
415.3-415.5
Fire
Fire |
- |
pdf_text |
| 415.6-415.8.1 |
415.6-415.8.1
Building/Fire
Building |
- |
pdf_text |
| 415.6-415.8.1 |
415.6-415.8.1
Building/Fire
Building |
- |
pdf_text |
| 415.8.2 |
415.8.2
Fire
Fire |
- |
pdf_text |
| 415.8.2 |
415.8.2
Fire
Fire |
- |
pdf_text |
| 415.8.3-415.8.5 |
415.8.3-415.8.5
Building/Fire
Building |
- |
pdf_text |
| 415.8.3-415.8.5 |
415.8.3-415.8.5
Building/Fire
Building |
- |
pdf_text |
| 415.9.1 |
415.9.1
Building/Fire
Fire |
- |
pdf_text |
| 415.9.1 |
415.9.1
Building/Fire
Fire |
- |
pdf_text |
| 415.9.1.1-415.9.1.2 |
415.9.1.1-415.9.1.2
Building/Fire
Building |
- |
pdf_text |
| 415.9.1.1-415.9.1.2 |
415.9.1.1-415.9.1.2
Building/Fire
Building |
- |
pdf_text |
| 415.9.1.3-415.9.1.6 |
415.9.1.3-415.9.1.6
Fire
Fire |
- |
pdf_text |
| 415.9.1.3-415.9.1.6 |
415.9.1.3-415.9.1.6
Fire
Fire |
- |
pdf_text |
| 415.9.1.7 |
415.9.1.7
Building/Fire
Building |
- |
pdf_text |
| 415.9.1.7 |
415.9.1.7
Building/Fire
Building |
- |
pdf_text |
| 415.9.1.8-415.9.2 |
415.9.1.8-415.9.2
Fire
Fire |
- |
pdf_text |
| 415.9.1.8-415.9.2 |
415.9.1.8-415.9.2
Fire
Fire |
- |
pdf_text |
| 415.9.3-415.10.1 |
415.9.3-415.10.1
Building/Fire
Fire |
- |
pdf_text |
| 415.9.3-415.10.1 |
415.9.3-415.10.1
Building/Fire
Fire |
- |
pdf_text |
| 416.1-416.3.1 |
416.1-416.3.1
Building/Fire
Building |
- |
pdf_text |
| 416.1-416.3.1 |
416.1-416.3.1
Building/Fire
Building |
- |
pdf_text |
| 416.4-416.5 |
416.4-416.5
Fire
Fire |
- |
pdf_text |
| 416.4-416.5 |
416.4-416.5
Fire
Fire |
- |
pdf_text |
| 417.1-417.3 |
417.1-417.3
Building
Building |
- |
pdf_text |
| 417.1-417.3 |
417.1-417.3
Building
Building |
- |
pdf_text |
| 417.4 |
417.4
Fire
Fire |
- |
pdf_text |
| 417.4 |
417.4
Fire
Fire |
- |
pdf_text |
| 418 |
418
Building/Fire
Building |
- |
pdf_text |
| 418 |
418
Building/Fire
Building |
- |
pdf_text |
| 420.1-420.3 |
420.1-420.3
Building/Fire
Building |
- |
pdf_text |
| 420.1-420.3 |
420.1-420.3
Building/Fire
Building |
- |
pdf_text |
| 420.11-421.4 |
420.11-421.4
Building/Fire
Fire |
- |
pdf_text |
| 420.11-421.4 |
420.11-421.4
Building/Fire
Fire |
- |
pdf_text |
| 420.4-420.5 |
420.4-420.5
Fire
Fire |
- |
pdf_text |
| 420.4-420.5 |
420.4-420.5
Fire
Fire |
- |
pdf_text |
| 420.6-420.7 |
420.6-420.7
Building/Fire
Building |
- |
pdf_text |
| 420.6-420.7 |
420.6-420.7
Building/Fire
Building |
- |
pdf_text |
| 420.8-420.10 |
420.8-420.10
Fire
Fire |
- |
pdf_text |
| 420.8-420.10 |
420.8-420.10
Fire
Fire |
- |
pdf_text |
| 421.5-421.6 |
421.5-421.6
Fire
Fire |
- |
pdf_text |
| 421.5-421.6 |
421.5-421.6
Fire
Fire |
- |
pdf_text |
| 421.7 |
421.7
Fire/Electrical
Electrical |
- |
pdf_text |
| 421.7 |
421.7
Fire/Electrical
Electrical |
- |
pdf_text |
| 422.1-422.3.3 |
422.1-422.3.3
Building/Fire
Building |
- |
pdf_text |
| 422.1-422.3.3 |
422.1-422.3.3
Building/Fire
Building |
- |
pdf_text |
| 422.4-422.5 |
422.4-422.5
Fire
Fire |
- |
pdf_text |
| 422.4-422.5 |
422.4-422.5
Fire
Fire |
- |
pdf_text |
| 422.6 |
422.6
Electrical
Electrical |
- |
pdf_text |
| 422.6 |
422.6
Electrical
Electrical |
- |
pdf_text |
| 422.7 |
422.7
Fire
Fire |
- |
pdf_text |
| 422.7 |
422.7
Fire
Fire |
- |
pdf_text |
| 424.1-424.2 |
424.1-424.2
Building/Fire
Building |
- |
pdf_text |
| 424.1-424.2 |
424.1-424.2
Building/Fire
Building |
- |
pdf_text |
| 424.3 |
424.3
Fire
Fire |
- |
pdf_text |
| 424.3 |
424.3
Fire
Fire |
- |
pdf_text |
| 424.4-424.5 |
424.4-424.5
Building/Fire
Building |
- |
pdf_text |
| 424.4-424.5 |
424.4-424.5
Building/Fire
Building |
- |
pdf_text |
| 425.1 |
425.1
As applicable
As applicable |
- |
pdf_text |
| 425.1 |
425.1
As applicable
As applicable |
- |
pdf_text |
| 426.1 |
426.1
Fire
Fire |
- |
pdf_text |
| 426.1 |
426.1
Fire
Fire |
- |
pdf_text |
| 426.1.1-426.1.3 |
426.1.1-426.1.3
Building/Fire
Building |
- |
pdf_text |
| 426.1.1-426.1.3 |
426.1.1-426.1.3
Building/Fire
Building |
- |
pdf_text |
| 426.1.4 |
426.1.4
Fire
Fire |
- |
pdf_text |
| 426.1.4 |
426.1.4
Fire
Fire |
- |
pdf_text |
| 426.1.5-426.1.7 |
426.1.5-426.1.7
Building/Fire
Building |
- |
pdf_text |
| 426.1.5-426.1.7 |
426.1.5-426.1.7
Building/Fire
Building |
- |
pdf_text |
| 427.1-427.2.2 |
427.1-427.2.2
Building/Fire
Building |
- |
pdf_text |
| 427.1-427.2.2 |
427.1-427.2.2
Building/Fire
Building |
- |
pdf_text |
| 427.2.3 |
427.2.3
Building/Fire
Fire |
- |
pdf_text |
| 427.2.3 |
427.2.3
Building/Fire
Fire |
- |
pdf_text |
| 428.1-428.3.5 |
428.1-428.3.5
Building/Fire
Building |
- |
pdf_text |
| 428.1-428.3.5 |
428.1-428.3.5
Building/Fire
Building |
- |
pdf_text |
| 428.3.6 |
428.3.6
Electrical/Fire
Electrical |
- |
pdf_text |
| 428.3.6 |
428.3.6
Electrical/Fire
Electrical |
- |
pdf_text |
| 428.3.7-428.3.8 |
428.3.7-428.3.8
Building/Fire
Building |
- |
pdf_text |
| 428.3.7-428.3.8 |
428.3.7-428.3.8
Building/Fire
Building |
- |
pdf_text |
| 428.3.9-428.4 |
428.3.9-428.4
Building/Fire
Fire
C
h. |
- |
pdf_text |
| 428.3.9-428.4 |
428.3.9-428.4
Building/Fire
Fire
Ch. |
- |
pdf_text |
| 43 |
43" shall be deleted and "the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inse
ix. At Section R302.6, Dwelling-unit garage fire separation, "Attachment of gyps
shall comply with Table R702.3.5." shall be deleted.
x. Table R302.6, Dwelling-Unit Garage Separation, shall be amended as follows:
column entitled "Material" and the rows entitled "From portions of the dwelling un
the garage" and "Structure(s) supporting floor/ceiling assemblies used for separati
required by this section," the text shall be deleted and "constructed with not less th
one-hour fire resistance rating (see N.J.U.C.C. FTO-13)" shall be inserted.
xi. At Section R306.1, General, "repair" shall be deleted and "restoration" shall be
inserted.
xii. Section R306.1.1, Alternative provisions, shall be deleted in its entirety.
xiii. At Section R306.1.6, Protection of mechanical, plumbing and electrical syste
second sentence shall be deleted.
xiv. At Section R306.1.7, Protection of water supply and sanitary sewage systems
first and second sentences, "and replacement" shall be deleted. Also, in the second
sentence, "the plumbing provisions of this code and Chapter 3 of the International
Sewage Disposal Code" shall be deleted and "the plumbing subcode (N.J.A.C. 5:2
shall be inserted.
xv. At Section R306.1.9, Manufactured homes, in the first sentence, "new and
replacement" shall be deleted and "relocated" shall be inserted in lieu thereof. |
- |
pdf_text |
| 43 |
43" shall be deleted and "the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inse
ix. In Section R302.5.1, Opening protection, in the last sentence, ", Doors shall be
latching and equipped with a self-closing or automatic-closing device" shall be del
x. In Section R302.6, Dwelling-garage fire separation, "Attachment of gypsum bo
comply with Table R702.3.5." shall be deleted.
xi. Table R302.6, Dwelling-Garage Separation, shall be amended as follows: In th
column entitled "Material" and the rows entitled "From habitable rooms above the
and "Structure(s) supporting floor/ceiling assemblies used for separation required
section," the text shall be deleted and "constructed with not less than a one-hour fir
resistance rating (see N.J.U.C.C. FTO-13)" shall be inserted. |
- |
pdf_text |
| 450.21 |
450.21(B)
Building/Electrical
Building |
- |
pdf_text |
| 450.41-450.48 |
450.41-450.48
Electrical/Fire
Electrical |
- |
pdf_text |
| 450.41-450.48 |
450.41-450.48
Electrical/Fire
Electrical |
- |
pdf_text |
| 455-490 |
455-490
Electrical
Electrical
Ch. 5
Special Occupancies
Electrical/Fire
Electrical
Ch. 6
Special Equipment |
- |
pdf_text |
| 455-495 |
455-495
Electrical
Electrical
Ch. 5
Special Occupancies
Electrical/Fire
Electrical
Ch. 6
Special Equipment |
- |
pdf_text |
| 5 |
5:23-1.4 for any of the adopted national model codes as appropriate.
(b) The following chapters, sections, or pages of the International Mechanical Code/2021
amended as follows: |
- |
pdf_text |
| 5 |
5:23-1.4 for any of the adopted national model codes as appropriate.
(b) The following chapters, sections, or pages of the International Mechanical Code/2024
amended as follows: |
- |
pdf_text |
| 5 |
5
Ch.
Wall
Building
Building |
- |
pdf_text |
| 5 |
5. Chapter 5, Floors, shall be amended as follows:
i. At Section R502.12.4, entitled "Truss Design Drawings," the second sentence s
amended to insert "and truss layout drawings" after "Truss design drawings."
ii. New Section R502.12.5, entitled "Truss Identification," shall be inserted as foll
"Each truss shall be labeled or otherwise indelibly marked at the factory with the i
truss number as assigned in the truss layout plan. The indelible marking or label sh
located on the bottom chord of the truss, inside the bearing points. When indelible
markings are used, each digit shall be not less than one inch high. When labels are |
- |
pdf_text |
| 5 |
5. Amendments to Chapter 6, Aquatic recreation facilities, shall be amend
follows:
In Section 601.1, Scope, the following sentence shall be added to the e
paragraph, "For purposes of enforcement, Class D-2 and Class D-6 pub
shall be regulated by this chapter and N.J.A.C. 5:23; all other Class D p
pools shall be regulated by N.J.A.C. 5:14A."
In Section 609.1, General, "International Building Code and Internation
Plumbing Code and Section 609.2 through 609.9" shall be deleted and
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
Sections 609.2, Number of fixtures, 609.3, Showers, 609.4, Soap dispe |
- |
pdf_text |
| 5 |
5. Name of testing agency and test standard by which the fabric was tested."
ii. Section 3103.1.2, Permit required, shall be deleted in its entirety and the follow
be inserted: |
- |
pdf_text |
| 5 |
5
Building Envelope
Building
Building
Ch. |
- |
pdf_text |
| 5 |
5. Casino hotels; |
- |
pdf_text |
| 5 |
5. Chapter 5 of the fuel gas code, entitled "Chimneys and vents," shall be amended as
i. In Section 501.15.2, Flue passageways, in the first sentence, "free of obstruction
combustible deposits" shall be deleted and "inspected in accordance with the chim
verification program as provided for in N.J.A.C. 5:23-2.20(d)" shall be inserted.
ii. In Section 503.5.6, Inspection of chimneys, "examined to ascertain that it is cle
free of obstructions" shall be deleted and "inspected in accordance with the chimn
verification program as provided for in N.J.A.C. 5:23-2.20(d)" shall be inserted. |
- |
pdf_text |
| 5 |
5
Traps, Cleanouts and Backwater Valves
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 5 |
5:23-3.15" shall be inserted.
iii. In Table 1505.1, Minimum Roof Covering Classification for Types of Constru
Note a shall be deleted in its entirety. In addition, at Note b, "and Group U" shall b
deleted from the first sentence.
iv. In Section 1507.1.2, Ice barrier, "In areas where there has been a history of ice
along the eaves causing a backup of water," shall be deleted and "In areas where th
average daily temperature in January is 25 degrees F (-4 degrees C) or less," shall
inserted.
v. In Table 1507.4.3(1), METAL ROOF COVERINGS, the reference to note a in
line of the second column and note a at the end of the table shall be deleted.
vi. In Section 1507.5.7, Flashing, "or where there has is a possibility of ice formin
the eaves causing a backup of water," shall be deleted.
vii. In Section 1507.8.8, Flashing, "or where there is a possibility of ice forming a
eaves causing a backup of water," shall be deleted.
viii. In Section 1507.9.9, Flashing, "or where there is a possibility of ice forming
eaves causing a backup of water," shall be deleted.
ix. In Section 1507.17.4.2, Ice barrier, "In areas where there has been a history of
forming along the eaves causing a backup of water," shall be deleted and "In areas |
- |
pdf_text |
| 5 |
5. Under the heading of "Wind Design--Windborne debris region," insert "N/
Not Applicable; |
- |
pdf_text |
| 5 |
5. Chapter 5, Existing buildings, shall be deleted. |
- |
pdf_text |
| 5 |
5. A horizontal branch serving the lavatory and the bathtub or sho
shall connect to the stack at the same level as the water closet, or it
connect to the water closet bend, or the lavatory and bathtub or sho
may individually connect to the water closet bend. |
- |
pdf_text |
| 5 |
5. A public hearing for rehabilitation subcode code change proposals shall be held pri
scheduled Code Advisory Board meeting. The date and time of the public hearing on
rehabilitation subcode code change proposals may be obtained by contacting the Code
Development Unit at (609) 984-7609.
(c) The following apply to code change proposals to other State-developed subcodes: |
- |
pdf_text |
| 5 |
5 occupants".
xii. In Section 310.4, Residential Group R-3, in the second and third line "in natur
be deleted. Additionally, in the list of occupancies, Congregate living facilities
(nontransient) with 16 or fewer occupants, shall be deleted and Boarding houses (n
transient) shall be amended by deleting "(non-transient)," and by inserting "with 5
occupants". The terms "Convents," "Dormitories," "Fraternities and Sororities,"
"Monasteries," "Congregate living facilities (transient) with 10 or fewer occupants
"Boarding Houses (transient)," and "Lodging houses with five or fewer guest room
or fewer occupants" shall be deleted. The terms "Alcohol and drug treatment hous
or fewer residents," "Detached one- and two-family dwellings greater than three st
height, multiple single-family townhouses greater than three stories in height, attac
two-family dwellings separated from adjacent units by firewalls, and other one- an |
- |
pdf_text |
| 5 |
5. Chapter 5, General Building Heights and Areas, shall be amended as follows:
i. Section 502, Building Address, shall be deleted in its entirety.
ii. Table 504.3 "ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRAD
PLANE" shall be amended as follows:
(1) In the first column, OCCUPANCY CLASSIFICATION, Group U shall be
(2) In the first column, OCCUPANCY CLASSIFICATION, superscript i shall
inserted at Group I-4. In addition, the following note shall be added to the table
Child-care facilities of Types IIB, III, IV HT, or V construction shall be limite
feet in height above grade plane."
(3) c, d, e, f and h shall be deleted.
(4) Under Occupancy Classification H-1, H-2, H-3, and H-5, the NS in the sec
column shall be deleted.
(5) Under Occupancy Classification H-4, the row that begins with NS shall be |
- |
pdf_text |
| 5 |
5. Tanks situated in an underground area, including, but not limited to, basements, cel
mines, drift shafts, or tunnels, if the storage tank is situated upon or above the surface
floor; |
- |
pdf_text |
| 5 |
5
Floors
Building
Building
Ch. |
- |
pdf_text |
| 5 |
5:23-1.4 for any of the adopted national model codes as appropriate.
(b) The following chapters, sections, or pages of the International Fuel Gas Code/2021 sh
amended as follows: |
- |
pdf_text |
| 5 |
5. Whenever a model code change hearing is scheduled so as not to allow adequate ti
meet the procedures set forth in this section and in N.J.S.A. 52:27D-124 of the Act, th
Commissioner may hold a hearing and require the advice of the Code Advisory Board
lesser time period, as the situation dictates.
(b) The following apply to rehabilitation subcode code change proposals: |
- |
pdf_text |
| 5 |
5:23-3.15" shall be inserted.
iii. At Table 1505.1, Minimum Roof Assembly Classification for Types of Const
Notes a and b shall be deleted in their entirety.
iv. At Section 1507.1.2, Ice barriers, "In areas where there has been a history of i
forming along the eaves causing a backup of water," shall be deleted and "In areas
the average daily temperature in January is 25 degrees F (-4 degrees C) or less," sh
inserted.
v. At Table 1507.4.3, METAL ROOF COVERINGS, the reference to note a in th
seventh line of the second column and note a at the end of the table shall be delete
vi. At Section 1507.5.7, Flashing, "or where there is a possibility of ice forming a
eaves causing a backup of water," in the fourth line shall be deleted.
vii. At Section 1507.8.8, Flashing, "or where there is a possibility of ice forming
eaves causing a backup of water," in the fifth line shall be deleted.
viii. At Section 1507.9.9, Flashing, "or where there is a possibility of ice forming
the eaves causing a backup of water," in the fifth line shall be deleted.
ix. In Section 1507.17.4.2, Ice barrier, "In areas where there has been a history of
forming along the eaves causing a backup of water," shall be deleted and "In areas
the average daily temperature in January is 25 degrees F (-4 degrees C) or less," sh
inserted. |
- |
pdf_text |
| 5 |
5. Amendments to Chapter 6, Aquatic recreation facilities, shall be amend
follows: |
- |
pdf_text |
| 5 |
5. Mechanical Subcode:
Cha
pter
Section/Title
Responsibility
Inspection
Plan Review
Ch. |
- |
pdf_text |
| 5 |
5. Chapter 4 of the electrical subcode, entitled "Equipment for General Use" is amend
follows:
i. Section 406.4(D)(4), entitled "Arc-Fault Circuit-Interrupter Protection," is delet
entirety.
ii. Article 425, entitled "Fixed Resistance and Electrode Industrial Process Heatin
Equipment," is amended as follows:
(1) Section 425.6, entitled "Listed Equipment," is deleted.
(2) Section 425.8, entitled "General," including subsections (A)-(C) are delete
(3) Section 425.10, entitled "Special Permission," is deleted.
(4) Section 425.12, entitled "Locations," including subsections (A) and (B) are
(5) Section 425.13, entitled "Spacing from Combustible Material," is deleted.
(6) Section 425.14, entitled "Infrared Lamp Industrial Process Heating Equip
deleted.
(7) Section 425.22(B), entitled "Resistance Elements," is deleted.
(8) Section 425.22(C), entitled "Overcurrent Devices," is deleted.
(9) Section 425.29, entitled "Marking of Heating Elements," is deleted. |
- |
pdf_text |
| 5 |
5. Chapter 5, General Building Heights and Areas, shall be amended as follows:
i. Section 502, Building Address, shall be deleted in its entirety.
ii. Table 504.3 "ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRAD
PLANE" shall be amended as follows:
(1) In the first column, OCCUPANCY CLASSIFICATION, Group U shall be
(2) In the first column, OCCUPANCY CLASSIFICATION, superscript <i> s
inserted at Group I-4. In addition, the following note shall be added to the table
Child-care facilities of Types IIB, III, IV HT, or V construction shall be limite
feet in height above grade plane."
(3) Footnotes c, d, e, f and h shall be deleted.
(4) Under Occupancy Classification H-1, H-2, H-3, and H-5, the NS in the sec
column shall be deleted.
(5) Under Occupancy Classification H-4, the row that begins with NS shall be
(6) Under Occupancy Classification I-1 Condition 1, I-3, the row that begins
shall be deleted.
(7) Under Occupancy Classification I-1 Condition 2, I-2, the row that begins
shall be deleted. |
- |
pdf_text |
| 5 |
5. Chapter 6 of the mechanical subcode, entitled "Duct Systems," is amended as follo
i. Section 602.2.1, Materials in plenums, is amended to modify Exception 3 to rea
section shall not apply to materials exposed within plenums in one-and two-family
dwellings. Wire exposed in plenums of one-and two-family dwellings shall confor
requirements of the electrical subcode."
ii. Section 602.2.1.1, Wiring, is deleted in its entirety and substitute the following
language: "Wiring, cable and raceways installed in a plenum shall be listed and ins
accordance with the electrical subcode." |
- |
pdf_text |
| 5 |
5. Chapter 5, Existing Buildings, shall be deleted. |
- |
pdf_text |
| 5 |
5. Location of fire alarm control unit, transponders and notification power |
- |
pdf_text |
| 5 |
5
Chimneys and Vents
Building/Fire
Fire (except 501.3, |
- |
pdf_text |
| 5 |
5:23-1.4 for any of the adopted national model codes as appropriate.
(b) The provisions of this subcode shall apply to detached one- and two-family dwellings
townhouses not more than three stories above grade plane in height with a separate means
egress serving each dwelling unit and their accessory structures.
(c) The following chapters or sections of the IRC/2024 shall be modified as follows: |
- |
pdf_text |
| 5 |
5:23) shall apply." shall be inserted under each section title, except that the "altern
materials" section shall state "The provisions of N.J.A.C. 5:23-3.7 shall apply." |
- |
pdf_text |
| 5 |
5
Building Envelope
Building
Building
Ch. |
- |
pdf_text |
| 5 |
5. Chapter 4 of the electrical subcode, entitled "Equipment for General Use" is amend
follows:
i. Section 406.4(D)(4), entitled "Arc-Fault Circuit-Interrupter Protection," is delet
entirety.
ii. Article 425, entitled "Fixed Resistance and Electrode Industrial Process Heatin
Equipment," is amended as follows:
(1) Section 425.6, entitled "Listed Equipment," is deleted.
(2) Section 425.10, entitled "General," including subsections (A)-(C) are delet
(3) Section 425.12, entitled "Locations," including subsections (A) and (B) are
(4) Section 425.13, entitled "Spacing from Combustible Material," is deleted. |
- |
pdf_text |
| 5 |
5. Mechanical Subcode:
Cha
pter
Section/Title
Responsibility
Plan Review
Inspection
Ch. |
- |
pdf_text |
| 5 |
5. Chapter 6, Aquatic recreation facilities, shall be amended as follows: |
- |
pdf_text |
| 5 |
5:23)" shall be inserted in its place.
ii. In Section 1701.1, Scope, "shall apply to Class 1 buildings, mass timber eleme
Type IV-A, IV-B, and IV-C construction, and smoke control systems in all buildin
shall be inserted after "chapter."
iii. Section 1703.1, Approved agency, shall be amended as follows: In the first sen
"Upon the request of the construction official" shall be inserted before "An." In the
sentence, "building official" shall be deleted and "construction official" shall be in
and "applicable" shall be deleted and "following" shall be inserted.
iv. In Section 1703.1.1, Independence, in the second sentence, "building official"
deleted and "construction official" shall be inserted. Additionally, "registered desi
professional" shall be deleted and "person" shall be inserted.
v. Add new section 1703.1.4 as follows: "1703.1.4 Certification. An approved age
shall employ personnel certified in accordance with the administrative provisions
Uniform Construction Code, to conduct, supervise and evaluate tests or inspection
vi. In Section 1703.3, Record of approval, in the first sentence, "building official"
deleted and "construction official" shall be inserted.
vii. In Section 1703.4, Performance, in the first sentence, "building official" shall
deleted and "construction official" shall be inserted.
viii. In Section 1703.4.1, Research and investigation, in the first and second sente
"building official" shall be deleted and "construction official" shall be inserte |
- |
pdf_text |
| 5 |
5. Chapter 6 of the mechanical subcode, entitled "Duct Systems," is amended as follo
i. Section 602.3, Materials within plenums, is amended to modify Exception 3 to r
"This section shall not apply to materials exposed within plenums in one-and two-
dwellings. Wire exposed in plenums of one-and two-family dwellings shall confor
requirements of the electrical subcode."
ii. Section 602.3.3, Wiring, is deleted in its entirety and substitute the following la
"Wiring, cable and raceways installed in a plenum shall be listed and installed in
accordance with the electrical subcode." |
- |
pdf_text |
| 5 |
5
Exhaust Systems |
- |
pdf_text |
| 5 |
5
Chimneys and Vents
Buildin
g/Fire
Fire (except 501.3, 501.11, |
- |
pdf_text |
| 5 |
5. Chapter 5, Floors, shall be amended as follows:
i. In Section R502.11.4, entitled "Truss Design Drawings," the second sentence sh
amended to insert "and truss layout drawings" after "Truss design drawings."
ii. New Section R502.11.5, entitled "Truss Identification," shall be inserted as foll
"Each truss shall be labeled or otherwise indelibly marked at the factory with the i
truss number as assigned in the truss layout plan. The indelible marking or label sh
located on the bottom chord of the truss, inside the bearing points. When indelible
markings are used, each digit shall be not less than one inch high. When labels are
the label shall be a minimum of five inches by three inches and shall be affixed to
by a truss plate. Labels shall remain affixed to the truss."
iii. In Section R506.2.2, Base, in the exception, "Table R405.1" shall be deleted a
"Table R406.1" shall be inserted. |
- |
pdf_text |
| 5 |
5:23-3.15, or to the rehabilitation subcode, N.J.A.C. 5:23-6, as appropriate.
(b) The following chapters of the building subcode are modified, as follows: |
- |
pdf_text |
| 5 |
5:23-2.34."
iv. In the exception of Section 3313, Water supply for fire protection, the term "fir
official" shall be replaced with the term "fire official."
v. In Section 3314, Fire watch during construction, the term "fire code official" sh
replaced with the term "fire official". |
- |
pdf_text |
| 5 |
5. In section 309.1, "Operable parts", Exception 2 shall be deleted, and the foll
shall be inserted: "Receptacle outlets provided in a Type A kitchen above a len
countertop." |
- |
pdf_text |
| 5 |
5
Traps, Cleanouts and Backwater Valves
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 5 |
5. A three-sided turn-out shed used to shelter livestock shall be exempt from the perm
requirements of the Uniform Construction Code provided there is no permanent found
floor and provided the structure is 250 square feet or less in area and 14 feet or less in
and has no utility (water, gas, oil, sewer or electric) connections.
i. The structure shall be of sufficient weight to remain in place or shall be anchore
ground. Concrete shall not be required for anchoring. |
- |
pdf_text |
| 5 |
5. Approvals and interrelations. |
- |
pdf_text |
| 5 |
5
General Building
Building/Fire,
Building, except as below
Heights and Areas
except as
below: |
- |
pdf_text |
| 5 |
5:23-2.15(f)2ii, including a reference set of plans, the prototype file identification num
plan number and date of the released prototype plan, to the municipal enforcing agenc
(d) The department may perform field inspections for any of the above projects when it d
such activity appropriate. However, such action shall not relieve the municipality of the o
to perform field inspections for any project for which the municipality has granted a permi
(e) Whenever the department shall determine that there exists a violation of these regulati
shall take appropriate action and shall provide the municipality with copies of all notices,
and other applicable information. The department and any municipality may consolidate o
other steps to expedite any matter of which they jointly complain, but in no event shall the
of any building subject to the act be sanctioned twice for the same violations.
(f) In any case where the department shall notify a municipality that a violation exists, no
certificate of occupancy may issue until the department notifies the municipality that the v
has been abated. |
- |
pdf_text |
| 5 |
5:23-1.4 for any of the adopted national model codes as appropriate.
(b) The following chapters, sections or pages of the International Fuel Gas Code/2024 sh
amended as follows: |
- |
pdf_text |
| 5 |
5. Chapter 5 of the plumbing subcode entitled, "Traps, Cleanouts and Backwater Valv
shall be amended as follows:
i. In Section 5.3.2, Trap seals, in Exception (2), "in accordance with N.J.A.C. 5:23
shall be inserted after "Authority Having Jurisdiction."
ii. In Section 5.3.4, Building traps, "in accordance with N.J.A.C. 5:23-3.3" shall b
inserted after "Authority Having Jurisdiction."
iii. In Section 5.4.6, Building Drain and Building Sewer Junctions and the Propert
in subsection b, "in accordance with the requirements of the Authority Having Juri
shall be deleted.
iv. In Section 5.4.10, Manholes for Large Pipes, subsection d shall be deleted. |
- |
pdf_text |
| 5 |
5. Chapter 5 of the fuel gas code, entitled "Chimneys and vents," shall be amended as |
- |
pdf_text |
| 5 |
5. Amendments to released plans and specifications for reasons other than educationa
adequacy shall be submitted for review and release to the Department or the municipal
enforcing agency, whichever originally released the plans. |
- |
pdf_text |
| 5 |
5. Name of testing agency and test standard by which the fabric was tested."
ii. Section 3103.1.3, Permit required, shall be deleted in its entirety and the follo
shall be inserted:
"Temporary structures, tents, tensioned membrane structures, and canopies me
criteria in N.J.A.C. 5:23-2.14 shall not require a permit. Greenhouses meeting t
criteria in N.J.A.C. 5:23-3.2(d) shall not require a permit."
iii. In Section 3104.2, Separate structures, Exception 2 shall be deleted.
iv. New Section 3109.2, Amendments to the International Swimming Pool and S
shall be inserted as follows: |
- |
pdf_text |
| 5 |
5
General Building
Building/Fire,
Building, except as below
Heights and Areas
except as
below: |
- |
pdf_text |
| 5 (cont. 2) |
d.
ix. In Section 1703.6, Evaluation and follow-up inspection services, "in accordanc
N.J.A.C. 5:23-4.26" shall be inserted after the second "assembly." Additionally, in
second and last sentence, "building official" shall be deleted and "construction offi
shall be inserted. |
- |
pdf_text |
| 5.1 |
5.1 In Section 601.1, Scope, the following sentence shall be added to t
the paragraph, "For purposes of enforcement, Class D-2 and Class D-6
pools shall be regulated by this chapter and N.J.A.C. 5:23; all other Cla
public pools shall be regulated by N.J.A.C. 5:14A." |
- |
pdf_text |
| 5.1 |
5.1 In Section 601.1, Scope, the following sentence shall be added to th
the paragraph, "For purposes of enforcement, Class D-2 and Class D-6
pools shall be regulated by this chapter and N.J.A.C. 5:23; all other Cla
public pools shall be regulated by N.J.A.C. 5:14A." |
- |
pdf_text |
| 5.1 |
5.1 At Section 601.1, Scope, the following sentence shall be added to the e
the paragraph, "For purposes of enforcement, Class D-2 and Class D-6 pub
shall be regulated by this chapter and N.J.A.C. 5:23; all other Class D publi
shall be regulated by N.J.A.C. 5:14A." |
- |
pdf_text |
| 5.2 |
5.2 In Section 609.1, General, "International Building Code and Intern
Plumbing Code and Section 609.2 through 609.9" shall be deleted and
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 5.2 |
5.2 At Section 609.1, General, "International Building Code and Internatio
Plumbing Code and Section 609.2 through 609.9" shall be deleted and "the
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 5.2 |
5.2 In Section 609.1, General, "International Building Code and Interna
Plumbing Code and Section 609.2 through 609.9" shall be deleted and
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 5.3 |
5.3 Sections 609.2, Number of fixtures, 609.3, Showers, 609.4, Soap
dispensers, 609.5, Toilet tissue holder, 609.6, Lavatory mirror, 609.7, S
napkin receptacles, 609.8, Sanitary napkin dispensers, and 609.9, Infan
shall be deleted. |
- |
pdf_text |
| 5.3 |
5.3 Sections 609.2, Number of fixtures, 609.3, Showers, 609.4, Soap dispe |
- |
pdf_text |
| 5.3 |
5.3 Sections 609.2, Number of fixtures, 609.3, Showers, 609.4, Soap di |
- |
pdf_text |
| 500 |
500 gpm (1892 L/min.) plus the sprinkler demand for the first riser, plus 25
(945 L/min.) for each additional riser, and the total shall not be required to |
- |
pdf_text |
| 501 |
501
Building
Building |
- |
pdf_text |
| 501 |
501
Building
Building |
- |
pdf_text |
| 501.1-506.1 |
501.1-506.1
Building
Building |
- |
pdf_text |
| 501.11 |
501.11
Building/Fire
Building |
- |
pdf_text |
| 501.11 |
501.11
Buildin
g/Fire
Building |
- |
pdf_text |
| 501.15.3 |
501.15.3
Building/Fire
Building |
- |
pdf_text |
| 501.15.3 |
501.15.3
Buildin
g/Fire
Building |
- |
pdf_text |
| 501.3 |
501.3
Building/Fire
Building |
- |
pdf_text |
| 501.3 |
501.3
Buildin
g/Fire
Building |
- |
pdf_text |
| 502 |
502
Building/Fire
Building |
- |
pdf_text |
| 502 |
502
Building/Fire
Building |
- |
pdf_text |
| 503 |
503
Building/Fire
Fire |
- |
pdf_text |
| 503 |
503
Building/Fire
Fire |
- |
pdf_text |
| 503.5.11 |
503.5.11
Building/Fire
Fire |
- |
pdf_text |
| 503.5.11 |
503.5.11
Buildin
g/Fire
Fire
Ch. |
- |
pdf_text |
| 503.5.3 |
503.5.3
Buildin
g/Fire
Building |
- |
pdf_text |
| 503.5.3 |
503.5.3
Building/Fire
Building |
- |
pdf_text |
| 503.5.8-503.5.10 |
503.5.8-503.5.10
Building
Building |
- |
pdf_text |
| 503.5.8-503.5.10 |
503.5.8-503.5.10
Buildin
g
Building |
- |
pdf_text |
| 504 |
504
Building/Fire
Building |
- |
pdf_text |
| 504 |
504
Building/Fire
Building |
- |
pdf_text |
| 504.3 |
504.3 and 506.2" for "Table 503".
Amended by R.2022 d.158, effective December 19, 2022.
See: 54 N.J.R. 476(a), 54 N.J.R. 2371(c).
In (d)11, inserted ", 504.4,".
Amended by R.2023 d.030, effective March 6, 2023.
See: 54 N.J.R. 1661(a), 55 N.J.R. 349(a).
In (d)8i, substituted "Section 1008" for "section 1006"; and in (d)11, inserted ", 504.4,".
Administrative correction, effective July 2, 2024.
See: 56 N.J.R. 1557(a).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| 504.3 |
504.3 and 506.2" for "Table 503".
Amended by R.2022 d.158, effective December 19, 2022.
See: 54 N.J.R. 476(a), 54 N.J.R. 2371(c).
In (d)11, inserted ", 504.4,".
Amended by R.2023 d.030, effective March 6, 2023.
See: 54 N.J.R. 1661(a), 55 N.J.R. 349(a).
In (d)8i, substituted "Section 1008" for "section 1006"; and in (d)11, inserted ", 504.4,".
Administrative correction, effective July 2, 2024.
See: 56 N.J.R. 1557(a).
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| 505-510 |
505-510
Building/Fire
Fire |
- |
pdf_text |
| 505-510 |
505-510
Building/Fire
Fire |
- |
pdf_text |
| 508.5.11 |
508.5.11
Plumbing
Plumbing
C
h. |
- |
pdf_text |
| 508.5.11 |
508.5.11
Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 508.5.7 |
508.5.7
Fire
Fire |
- |
pdf_text |
| 508.5.7 |
508.5.7
Fire
Fire |
- |
pdf_text |
| 508.5.8-508.5.10 |
508.5.8-508.5.10
Building
Building |
- |
pdf_text |
| 508.5.8-508.5.10 |
508.5.8-508.5.10
Building
Building |
- |
pdf_text |
| 511 |
511
Building
Building |
- |
pdf_text |
| 511 |
511
Building/Fire
Fire |
- |
pdf_text |
| 512 |
512
Building
Building |
- |
pdf_text |
| 512.1-512.10.5 |
512.1-512.10.5
Fire
Fire |
- |
pdf_text |
| 512.11-512.11.1 |
512.11-512.11.1
Building/Electrical/Fire
Electrical (except
rated enclosures,
which are Building) |
- |
pdf_text |
| 512.11.2 |
512.11.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 512.12-512.12.1 |
512.12-512.12.1
Fire
Fire |
- |
pdf_text |
| 512.12.2 |
512.12.2
Fire/Electrical
Electrical |
- |
pdf_text |
| 512.12.3-512.19 |
512.12.3-512.19
Fire
Fire |
- |
pdf_text |
| 513 |
513
Building
Building
Ch.
Duct Systems |
- |
pdf_text |
| 513.1 |
513.1- 513.10.5
Fire
Fire |
- |
pdf_text |
| 513.11-513.11.1 |
513.11-513.11.1
Building/Electrical/Fire
Electrical (except
rated enclosures,
which are Building) |
- |
pdf_text |
| 513.11.2 |
513.11.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 513.12-513.12.1 |
513.12-513.12.1
Fire
Fire |
- |
pdf_text |
| 513.12.2 |
513.12.2
Fire/Electrical
Electrical |
- |
pdf_text |
| 513.12.3-513.19 |
513.12.3-513.19
Fire
Fire |
- |
pdf_text |
| 514 |
514
Building
Building
Ch. |
- |
pdf_text |
| 6 |
6. Appendix A, Board of Appeals, shall be deleted in its entirety.
xliv. At Section R331.2, Installation, "Chapters 34 through 43" shall be deleted, a
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
xlv. At Section R332.1, General, the words "and existing" shall be deleted. |
- |
pdf_text |
| 6 |
6. Appendix A, Board of Appeals, shall be deleted in its entirety.
v. Section 3111.2, Solar thermal systems, "International Plumbing Code" shall be
and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
vi. Section 3113, Relocatable buildings, is deleted.
vii. Section 3114, Public use restroom buildings in flood hazard areas, shall be del
its entirety. |
- |
pdf_text |
| 6 |
6. Chapter 8 of the mechanical subcode, entitled "Chimneys and Vents," shall be ame
follows:
i. In Section 801.18.2, Flue passageways, in the first sentence, "free of obstruction
combustible deposits" shall be deleted and "inspected in accordance with the chim
verification program as provided for in N.J.A.C. 5:23-2.20(d)" shall be inserted. |
- |
pdf_text |
| 6 |
6. Chapter 6, Types of Construction, shall be amended as follows:
i. In Section 602.3, Type III, "(See FTO 14)" shall be inserted after "noncombusti
materials." In addition, the second sentence shall be deleted. |
- |
pdf_text |
| 6 |
6. The division of plan review responsibilities and State reserved activities; and |
- |
pdf_text |
| 6 |
6
Specific
Appliances |
- |
pdf_text |
| 6 |
6. Chapter 6, Referenced Standards, shall be amended as follows:
i. At the heading "ICC," amend the following title: |
- |
pdf_text |
| 6 |
6. Chapter 6, Referenced Standards, shall be amended as follows:
i. In the ICC table, "IPC-21, International Plumbing Code" shall be deleted and " |
- |
pdf_text |
| 6 |
6
Liquid Waste Treatment Equipment
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 6 |
6
Wall
Building
Building
Construction
Ch. |
- |
pdf_text |
| 6 |
6. Chapter 6, Wall Construction, shall be amended as follows:
i. In Figure R602.6.1, Top plate framing to accommodate piping, "8-10d nails" sh
deleted and "3-8d nails" shall be inserted.
ii. In Section R602.6.1, Drilling and notching of top plate, "eight 10d (0.148 inch
diameter)" shall be deleted and "3-8d" shall be inserted.
iii. Section R606.1.1, Professional registration not required, shall be deleted.
iv. In Section R608.1, General, the second sentence shall be deleted. |
- |
pdf_text |
| 6 |
6. Public mausoleums, vaults, crypts and other structures intended to hold or contain
remains; |
- |
pdf_text |
| 6 |
6. Release of the plans by the Department or the municipal code enforcing agency, as
may be, shall not preclude the enforcing agency doing the inspection from issuing a st
order in the event of a violation of the code. The enforcing agency doing the inspectio
not, however, issue a stop work order based on its disagreement with the released plan
the agency that released the plans, be it the Department or another local enforcing age
agrees that the issuance of such an order is appropriate. In the event that the enforcing
doing the inspection believes there to be an error in the plans, that enforcing agency sh
prompt notice of the error that is believed to exist to the Department or the municipal
that reviewed the plans, as the case may be.
(c) The Department or the municipal code enforcing agency providing construction code
release or inspection shall be responsible for enforcing the following Uniform Constructio
enhancements in public school facilities: |
- |
pdf_text |
| 6 |
6. Chapter 6 of the plumbing subcode, entitled "Liquid Waste Treatment Equipment,"
amended as follows:
i. At the end of Section 6.1.1, Where Required, the following shall be inserted: "T
determination of necessity shall be made by the plumbing subcode official in accor
with N.J.A.C. 5:23-3.3."
ii. In Section 6.1.4.1, General, "and the Authority Having Jurisdiction" shall be de
iii. Section 6.4.4, Alternate Design, is amended to add the phrase "in accordance
N.J.A.C. 5:23-3.3" after the word "approval" on line 4. |
- |
pdf_text |
| 6 |
6. Appendix A, Board of Appeals, shall be deleted in its entirety.
xliv. In Section R329.2, Installation, "Chapters 34 through 43" shall be deleted, an
electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
xlv. In Section R330.1, General, the words "and existing" shall be deleted. |
- |
pdf_text |
| 6 |
6. Appendix A, Board of Appeals, shall be deleted in its entirety.
v. Section 3111.2, Solar thermal systems, "International Plumbing Code" shall be
and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
vi. Section 3113, Relocatable buildings, is deleted. |
- |
pdf_text |
| 6 |
6. Tanks situated in an underground area, including, but not limited to, basements, cel
mines, drift shafts, or tunnels, if the storage tank is equipped with secondary containm
is uncovered so as to allow visual inspection of the exterior of the tank; |
- |
pdf_text |
| 6 |
6. When the bathroom group is the topmost load on a stack, a horiz
branch serving the lavatory and the bathtub or shower stall may con
the stack below the water closet bend, or the lavatory and the bathtu
shower stall may individually connect to the stack below the water
bend. |
- |
pdf_text |
| 6 |
6
Types of Construction
Building/Fire
Building
C
h. |
- |
pdf_text |
| 6 |
6. Delete section 406.6.2, "Location of detectable warning surfaces"; |
- |
pdf_text |
| 6 |
6
Types of Construction
Building/Fire
Building
Ch. |
- |
pdf_text |
| 6 |
6. Under the heading of "Seismic Design Category," insert "N/A" for Not App |
- |
pdf_text |
| 6 |
6. Chapter 6 of the fuel gas code, entitled "Specific Appliances," shall be amended as
i. In Section 614.11, Common exhaust systems for clothes dryers located in multis
structures, item 7, insert ", if provided," after the word "and".
ii. In Sections 624.1.1, Installation requirements, and 624.2, Water heaters utilized
space heating, "International Plumbing Code," shall be deleted and "plumbing sub
(N.J.A.C. 5:23-3.15)" shall be inserted.
iii. Section 627.10, Switches in electrical supply line, shall be deleted. |
- |
pdf_text |
| 6 |
6
Liquid Waste Treatment Equipment
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 6 |
6. Chapter 5 of the electrical subcode, entitled "Special Occupancies," is amended as
i. Section 514.3(B)(3), with the exception of subsection (e), is deleted.
ii. Section 525.5(B) of Article 525, entitled Carnivals, Circuses, Fairs and Similar
is deleted; it is replaced by Section 525.5(B) in the National Electrical Code 2005
follows:
"525.5(B) Clearances to Rides and Attractions. Amusement rides and a
attractions shall be maintained not less than 4.5 m (15 ft) in any direction from
conductors operating at 600 volts or less, except for the conductors suppl
amusement ride or attraction. Amusement rides or attractions shall not be located
within 4.5 m (15 ft) horizontally of conductors operating in excess of 600 volts."
iii. Part II of Article 550, entitled "Mobile Homes, Manufactured Homes, and Mo
Home Parks" comprising sections 550.11 through 550.25 is deleted. Section 550.1
be retained.
(1) Exception--Part II is retained in its entirety in the case of mobile/manufact
homes undergoing repair, renovation, or alteration.
iv. In Article 551, entitled "Recreation Vehicles and Recreation Vehicle Parks," d
from the title the words "Recreational Vehicles and." |
- |
pdf_text |
| 6 |
6. One- and Two-Family Dwelling Subcode:
Cha
pter
Section/Title
Responsibility
Plan Review
Inspection
Ch. |
- |
pdf_text |
| 6 |
6
Duct Systems |
- |
pdf_text |
| 6 |
6
Heating,
As applicable except
As applicable except
Ventilating, and Air
as below:
as below:
Conditioning |
- |
pdf_text |
| 6 |
6
Heating,
As applicable except
As applicable except
Ventilating, and Air
as below:
as below:
Conditioning |
- |
pdf_text |
| 6 |
6
Construction
Ch.
Wall Covering
Building
Building |
- |
pdf_text |
| 6 |
6
Specific
Appliances |
- |
pdf_text |
| 6 |
6. Chapter 6 of the fuel gas code, entitled "Specific Appliances," shall be amended as
i. In Section 614.11, Common exhaust systems for clothes dryers located in multis
structures, item 7, insert ", if provided," after the word "and".
ii. Section 627.10, Switches in electrical supply line, shall be deleted. |
- |
pdf_text |
| 6 |
6. One-and Two-Family Dwelling Subcode: |
- |
pdf_text |
| 6 |
6. Garden-type utility sheds and similar structures shall be exempt from the permit
requirements of the Uniform Construction Code provided the structure is 200 square f
less in area, 10 feet or less in height, has no utility (water, gas, oil, sewer or electric)
connections and the shed is dimensionally stable without the foundation system. A she
be considered dimensionally stable if it is provided with a floor system that is tied to t
of the structure such that it reacts to loads as a unit.
i. The structure shall be of sufficient weight to remain in place or shall be anchore
ground. Concrete shall not be required for anchoring. |
- |
pdf_text |
| 6 |
6. Chapter 6, Referenced Standards, shall be amended as follows:
i. In the ICC table, "IPC-21, International Plumbing Code" shall be deleted and "
National Standard Plumbing Code" shall be inserted. In addition, at the bottom of t
table, "**NSPC-21 is non-ICC and is published by the International Association o
Plumbing and Mechanical Officials" shall be inserted. |
- |
pdf_text |
| 6 |
6. Chapter 5 of the electrical subcode, entitled "Special Occupancies," is amended as
i. Section 514.3(B)(3), "Fuel Storage" with the exception of subsection (e), is dele
ii. Section 525.5(B), "Clearance to Portable Structures" of Article 525, entitled Ca
Circuses, Fairs and Similar Events, is deleted; it is replaced by Section 525.5(B) in
National Electrical Code 2005 as follows:
"525.5(B) Clearances to Rides and Attractions. Amusement rides and a
attractions shall be maintained not less than 4.5 m (15 ft) in any direction from
conductors operating at 600 volts or less, except for the conductors suppl
amusement ride or attraction. Amusement rides or attractions shall not be located
within 4.5 m (15 ft) horizontally of conductors operating in excess of 600 volts." |
- |
pdf_text |
| 6.4.4.1.1-6.4.4.1.2 |
6.4.4.1.1-6.4.4.1.2
Building
Building |
- |
pdf_text |
| 6.4.4.1.1-6.4.4.1.2 |
6.4.4.1.1-6.4.4.1.2
Building
Building |
- |
pdf_text |
| 6.4.4.1.3 |
6.4.4.1.3
Plumbing
Plumbing |
- |
pdf_text |
| 6.4.4.1.3 |
6.4.4.1.3
Plumbing
Plumbing |
- |
pdf_text |
| 6.4.4.1.4-6.4.4.1.5 |
6.4.4.1.4-6.4.4.1.5
Building
Building |
- |
pdf_text |
| 6.4.4.1.4-6.4.4.1.5 |
6.4.4.1.4-6.4.4.1.5
Building
Building |
- |
pdf_text |
| 6.4.4.2 |
6.4.4.2
Building
Building
Ch. |
- |
pdf_text |
| 6.4.4.2 |
6.4.4.2
Building
Building
Ch. |
- |
pdf_text |
| 600-610 |
600-610
Electrical
Electrical |
- |
pdf_text |
| 600-610 |
600-610
Electrical
Electrical |
- |
pdf_text |
| 601-602.2.1.6 |
601-602.2.1.6
Building/Fire
Building |
- |
pdf_text |
| 601-602.3.7 |
601-602.3.7
Building/Fire
Building |
- |
pdf_text |
| 602-603 |
602-603
Plumbing/Fire
Plumbing |
- |
pdf_text |
| 602-603 |
602-603
Plumbi
Plumbing |
- |
pdf_text |
| 602.1-602.2 |
602.1-602.2
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 602.2.1 |
602.2.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 602.2.1.7 |
602.2.1.7
Building/Fire/Plumbing
Plumbing |
- |
pdf_text |
| 602.2.1.8-603.1 |
602.2.1.8-603.1
Building/Fire
Building |
- |
pdf_text |
| 602.2.3 |
602.2.3- 602.4
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 602.3.8 |
602.3.8
Building/Fire/Plumbing
Plumbing |
- |
pdf_text |
| 602.4.1 |
602.4.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 602.4.2 |
602.4.2
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 603.1-603.6 |
603.1-603.6
Building
Building |
- |
pdf_text |
| 603.2 |
603.2
Building
Building |
- |
pdf_text |
| 603.2 |
603.2
Building
Building |
- |
pdf_text |
| 603.2.9-603.1 |
603.2.9-603.1
Building/Fire
Building |
- |
pdf_text |
| 603.3-605 |
603.3-605
Building/Fire
Building |
- |
pdf_text |
| 603.3-605 |
603.3-605
Building/Fire
Building |
- |
pdf_text |
| 604 |
604
Buildin
g/Fire
Building |
- |
pdf_text |
| 604 |
604
Building/Fire
Building |
- |
pdf_text |
| 604.1 |
604.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 604.11.2 |
604.11.2
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 604.11.3 |
604.11.3
Building/Plumb
ing
Building |
- |
pdf_text |
| 604.11.4 |
604.11.4
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 604.11.5 |
604.11.5
Building/Plumb
ing
Building |
- |
pdf_text |
| 604.11.6 |
604.11.6
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 604.11.7-605.1 |
604.11.7-605.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 604.2 |
604.2
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 604.3 |
604.3
Building/Plumb
ing
Building |
- |
pdf_text |
| 604.4 |
604.4
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 604.5 |
604.5
Building/Plumb
ing
Building |
- |
pdf_text |
| 604.6 |
604.6
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 604.7-604.11.1 |
604.7-604.11.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 605 |
605
Fire/Plumbing
Fire |
- |
pdf_text |
| 605 |
605
Fire/Pl
umbing
Fire |
- |
pdf_text |
| 605.2 |
605.2
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 605.3 |
605.3
Building/Plumb
ing
Building |
- |
pdf_text |
| 605.4 |
605.4
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 606 |
606
Building/Fire
Fire |
- |
pdf_text |
| 606 |
606
Building/Fire
Fire |
- |
pdf_text |
| 606-607 |
606-607
Buildin
g/Fire
Fire |
- |
pdf_text |
| 606-607 |
606-607
Building/Fire
Fire |
- |
pdf_text |
| 606.1-606.2 |
606.1-606.2
Building/Plumb
ing
Building for clear floor
space/Plumbing for fixture
mounting heights |
- |
pdf_text |
| 606.3-606.6 |
606.3-606.6
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 607 |
607
Building/Fire
Building |
- |
pdf_text |
| 607 |
607
Building/Fire
Building |
- |
pdf_text |
| 607.1-607.4.2.3 |
607.1-607.4.2.3
Building/Plumb
ing
Building |
- |
pdf_text |
| 607.5-607.6 |
607.5-607.6
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 607.7 |
607.7
Building/Plumb
ing
Building |
- |
pdf_text |
| 607.8 |
607.8
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 608 |
608
Building
Building
Ch. |
- |
pdf_text |
| 608 |
608
Building
Building
Ch. |
- |
pdf_text |
| 608-615 |
608-615
Buildin
g/Fire
Building |
- |
pdf_text |
| 608-615 |
608-615
Building/Fire
Building |
- |
pdf_text |
| 608.1-608.2 |
608.1-608.2
Building/Plumb
ing
Building for clear floor
space/Plumbing for fixture
mounting heights |
- |
pdf_text |
| 608.2.1.1 |
608.2.1.1
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 608.2.1.2-608.2.2 |
608.2.1.2-608.2.2
Building/Plumb
ing
Building |
- |
pdf_text |
| 608.2.1.2-608.2.2 |
608.2.1.2-608.2.2
A117.1 608.2.2.1
Building/Plumb
ing
Plumbing
A117.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 608.2.2.1 |
608.2.2.1
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 608.2.2.2-608.2.3 |
608.2.2.2-608.2.3
A117.1 608.2.3.1
Building/Plumb
ing
Plumbing
A117.1
Building/Plumb
ing
Building |
- |
pdf_text |
| 608.2.2.2-608.2.3 |
608.2.2.2-608.2.3
Building/Plumb
ing
Building |
- |
pdf_text |
| 608.2.3.1 |
608.2.3.1
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 608.2.3.2-608.3.3 |
608.2.3.2-608.3.3
Building/Plumb
ing
Building |
- |
pdf_text |
| 608.2.3.2-608.3.3 |
608.2.3.2-608.3.3
A117.1 608.4-608.5
Building/Plumb
ing
Plumbing
A117.1 608.6-608.7
Building/Plumb
ing
Building
A117.1 608.8
Building/Plumb
ing
Plumbing
A117.1 609-701.1
Building
Building
A117.1 702.1
Electrical/Fire
Electrical
A117.1 703.1-907.1
Building
Building
A117.1 1009
Building
Building
A117.1 1101.1-1102.6
Building
Building
A117.1 1102.7-1102.9
As applicable
As applicable
A117.1 1102.10
Building
Building |
- |
pdf_text |
| 608.4-608.5 |
608.4-608.5
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 608.6-608.7 |
608.6-608.7
Building/Plumb
Building |
- |
pdf_text |
| 608.8 |
608.8
Building/Plumb
ing
Plumbing |
- |
pdf_text |
| 609-701.1 |
609-701.1
Building
Building |
- |
pdf_text |
| 609.5 |
609.5, Toilet tissue holder, 609.6, Lavatory mirror, 609.7, Sanitary nap
receptacles, 609.8, Sanitary napkin dispensers, and 609.9, Infant Care,
deleted. |
- |
pdf_text |
| 609.5 |
609.5, Toilet tissue holder, 609.6, Lavatory mirror, 609.7, Sanitary napkin
receptacles, 609.8, Sanitary napkin dispensers, and 609.9, Infant Care, shal
deleted. |
- |
pdf_text |
| 611.3 |
611.3, entitled "Operable parts," and section 611.4, entitled "Height." |
- |
pdf_text |
| 616 |
616
Fire
Fire |
- |
pdf_text |
| 616 |
616
Fire
Fire |
- |
pdf_text |
| 617 |
617
Electric
al/
Electrical if electric/Plumbing if
Plumbi
ng
oil fired |
- |
pdf_text |
| 617 |
617
Electrical/ Plumbing
Electrical if
electric/Plumbing if oil
fired |
- |
pdf_text |
| 618 |
618
Building/Fire
Building |
- |
pdf_text |
| 618 |
618
Buildin
g/Fire
Building |
- |
pdf_text |
| 619 |
619
Plumbi
ng
Plumbing |
- |
pdf_text |
| 619 |
619
Plumbing
Plumbing |
- |
pdf_text |
| 620-622 |
620-622
Building/Fire
Building |
- |
pdf_text |
| 620-622 |
620-622
Buildin
g/Fire
Building |
- |
pdf_text |
| 620.1-620.12 |
620.1-620.12
Electrical/Elevator
<1>
Elevator/Electrica
<3> |
- |
pdf_text |
| 620.1-620.5 |
620.1-620.5
Electrical/Elevator
<1>
Elevator/Electric
<3> |
- |
pdf_text |
| 620.11-620.12 |
620.11-620.12
Electrical/Elevator
<1>
Elevator/Electric
<3> |
- |
pdf_text |
| 620.13 |
620.13
Electrical/Elevator
<1>
Electrical<2>
(on the line side
of the disconnect |
- |
pdf_text |
| 620.13 |
620.13
Electrical/Elevator
<1>
Electrical<2>
(on the line side
of the disconnect)
Elevator<2 >(on
the load side of
the disconnect)
Electrical<3> |
- |
pdf_text |
| 620.14-620.21 |
620.14-620.21
Electrical/Elevator
<1>
Elevator/Electrica
<3> |
- |
pdf_text |
| 620.14-620.21 |
620.14-620.21
Electrical/Elevator
<1>
Elevator/Electric
<3> |
- |
pdf_text |
| 620.22 |
620.22
Electrical/Elevator
<1>
Electrical<2>
(on the line side
of the disconnect
Elevator<2 >(on
the load side of
the disconnect)
Electrical<3> |
- |
pdf_text |
| 620.22 |
620.22
Electrical/Elevator
<1>
Electrical<2>
(on the line side
of the disconnect)
Elevator<2 >(on
the load side of
the disconnect)
Electrical<3> |
- |
pdf_text |
| 620.23-620.24 |
620.23-620.24
Electrical/Elevator
<1>
Electrical |
- |
pdf_text |
| 620.23-620.24 |
620.23-620.24
Electrical/Elevator
<1>
Electrical |
- |
pdf_text |
| 620.25-620.37 |
620.25-620.37
Electrical/Elevator
<1>
Elevator/Electrica
<3> |
- |
pdf_text |
| 620.25-620.37 |
620.25-620.37
Electrical/Elevator
<1>
Elevator/Electric
<3> |
- |
pdf_text |
| 620.38 |
620.38
Electrical/Elevator
<1>
Electrical |
- |
pdf_text |
| 620.38 |
620.38
Electrical/Elevator
<1>
Electrical |
- |
pdf_text |
| 620.41-620.44 |
620.41-620.44
Electrical/Elevator
<1>
Elevator/Electric
<3> |
- |
pdf_text |
| 620.41-620.44 |
620.41-620.44
Electrical/Elevator
<1>
Elevator/Electrica
<3> |
- |
pdf_text |
| 620.51 |
620.51(B)-(E)
Electrical/Elevator
<1>
Electrical/Elevato
<3> |
- |
pdf_text |
| 620.51 |
620.51(B)-(E)
Electrical/Elevator
<1>
Electrical/Elevat
<3> |
- |
pdf_text |
| 620.51-620.51 |
620.51-620.51(A)
Electrical/Elevator
<1>
Electrical |
- |
pdf_text |
| 620.51-620.51 |
620.51-620.51(A)
Electrical/Elevator
<1>
Electrical |
- |
pdf_text |
| 620.52 |
620.52
Electrical/Elevator
<1>
Elevator/Electrica
<3> |
- |
pdf_text |
| 620.52 |
620.52
Electrical/Elevator
<1>
Elevator/Electric
<3> |
- |
pdf_text |
| 620.53-620.55 |
620.53-620.55
Electrical/Elevator
<1>
Electrical<2
>(on the line sid
of the disconnect
Elevator<2 >(on |
- |
pdf_text |
| 620.53-620.55 |
620.53-620.55
Electrical/Elevator
<1>
Electrical<2
>(on the line side
of the disconnect)
Elevator<2 >(on
the load side of
the disconnect)
Electrical<3> |
- |
pdf_text |
| 620.6 |
620.6 (except for cartop
Electrical/Elevator
<1>
Elevator/Electric
<2>
receptacle(s))
(car top
receptacle only) |
- |
pdf_text |
| 620.61 |
620.61(C)-(D)
Electrical/Elevator
<1>
Electrical<2>
(on the line side
of the disconnect)
Elevator<2 >(on
the load side of
the disconnect)
Electrical<3> |
- |
pdf_text |
| 620.61 |
620.61(C)-(D)
Electrical/Elevator
<1>
Electrical<2>
(on the line side
of the disconnect
Elevator<2 >(on
the load side of
the disconnect)
Electrical<3> |
- |
pdf_text |
| 620.61 |
620.61(A)-(B)
Electrical/Elevator
<1>
Elevator/Electrica
<3> |
- |
pdf_text |
| 620.61 |
620.61(A)-(B)
Electrical/Elevator
<1>
Elevator/Electric
<3> |
- |
pdf_text |
| 620.62-620.84 |
620.62-620.84
Electrical/Elevator
<1>
Elevator/Electrica
<3> |
- |
pdf_text |
| 620.62-620.84 |
620.62-620.84
Electrical/Elevator
<1>
Elevator/Electric
<3> |
- |
pdf_text |
| 620.85 |
620.85 (except for cartop
Electrical/Elevator
<1>
Elevator/Electrica
<2
receptacle(s))
>(car top
receptacle only) |
- |
pdf_text |
| 620.85 |
620.85 (except for cartop
Electrical/Elevator
<1>
Elevator/Electric
<2
receptacle(s))
>(car top
receptacle only) |
- |
pdf_text |
| 620.91 |
620.91(B)
Electrical/Elevator
<1>
Electrical |
- |
pdf_text |
| 620.91 |
620.91(A) & (C)
Electrical/Elevator
<1>
Elevator/Electrica
<3> |
- |
pdf_text |
| 620.91 |
620.91(A) & (C)
Electrical/Elevator
<1>
Elevator/Electric
<3> |
- |
pdf_text |
| 620.91 |
620.91(B)
Electrical/Elevator
<1>
Electrical |
- |
pdf_text |
| 623 |
623
Fire
Fire |
- |
pdf_text |
| 623 |
623
Fire
Fire |
- |
pdf_text |
| 624 |
624
Plumbing
Plumbing |
- |
pdf_text |
| 624 |
624
Plumbi
ng
Plumbing |
- |
pdf_text |
| 625 |
625
Buildin
g/Fire
Building |
- |
pdf_text |
| 625 |
625
Building/Fire
Building |
- |
pdf_text |
| 625-694 |
625-694
Electrical
Electrical |
- |
pdf_text |
| 625-694 |
625-694
Electrical
Electrical |
- |
pdf_text |
| 626 |
626
Plumbi
ng
Plumbing |
- |
pdf_text |
| 626 |
626
Plumbing
Plumbing |
- |
pdf_text |
| 627.1-627.3 |
627.1-627.3
Plumbing
Plumbing |
- |
pdf_text |
| 627.1-627.3 |
627.1-627.3
Plumbi
ng
Plumbing |
- |
pdf_text |
| 627.10 |
627.10
Electrical
Electrical |
- |
pdf_text |
| 627.10 |
627.10
Electric
al
Electrical |
- |
pdf_text |
| 627.4-627.7 |
627.4-627.7
Buildin
g/Fire
Building |
- |
pdf_text |
| 627.4-627.7 |
627.4-627.7
Building/Fire
Building |
- |
pdf_text |
| 627.8-627.9 |
627.8-627.9
Plumbing
Plumbing |
- |
pdf_text |
| 627.8-627.9 |
627.8-627.9
Plumbi
ng
Plumbing |
- |
pdf_text |
| 628.1-628.3 |
628.1-628.3
Buildin
g/Fire
Building |
- |
pdf_text |
| 628.1-628.3 |
628.1-628.3
Building/Fire
Building |
- |
pdf_text |
| 628.4 |
628.4
Plumbing
Plumbing |
- |
pdf_text |
| 628.4 |
628.4
Plumbi
ng
Plumbing |
- |
pdf_text |
| 629-630 |
629-630
Building/Fire
Building |
- |
pdf_text |
| 629-630 |
629-630
Buildin
Building |
- |
pdf_text |
| 631-632 |
631-632
Plumbing
Plumbing |
- |
pdf_text |
| 631-632 |
631-632
Plumbi
ng
Plumbing |
- |
pdf_text |
| 633 |
633
Fire
Fire |
- |
pdf_text |
| 633 |
633
Fire
Fire |
- |
pdf_text |
| 634 |
634
See Chapter 7
See Chapter 7 |
- |
pdf_text |
| 634 |
634
See
See Chapter 7
Chapte
r 7 |
- |
pdf_text |
| 635 |
635
Fire/Pl
umbing
Plumbing
Ch. |
- |
pdf_text |
| 635 |
635
Fire/Plumbing
Plumbing
Ch. |
- |
pdf_text |
| 695 |
695
Electrical/Fire
Electrical
Ch. 7
Special Conditions |
- |
pdf_text |
| 695 |
695
Electrical/Fire
Electrical
Ch. 7
Special Conditions |
- |
pdf_text |
| 7 |
7. Fuel Gas Subcode:
Cha
pter
Section/Title
Respo
nsibilit
y
Inspection
Plan
Review
Ch. |
- |
pdf_text |
| 7 |
7
Combustion Air
Fire
Fire
Ch. |
- |
pdf_text |
| 7 |
7. Power connection. |
- |
pdf_text |
| 7 |
7. Appendices
i. Appendix RA, Board of Appeals--Residential, is deleted.
ii. Appendix RB, Solar-Ready Provisions--Detached One- and Two-Family Dwell
Townhouse, is optional at the discretion of the permit applicant.
iii. Appendices RC, Zero Net Energy Residential Building Provisions; RD, Electri
Energy Storage Provisions; RE, Electric Vehicle Charging Infrastructure; RF, Alte
Building Thermal Envelope Insulation R-Value Options; RG, 2024 IECC Stretch
RH, Operational Carbon Rating And Energy Reporting; RI, On-Site Renewable E
RJ, Demand Responsive Controls; RK, Electric-Ready Residential Building Provis
RL, Renewable Energy Infrastructure; are optional at the discretion of the permit a
Appendix RC and RH shall be amended as follows: |
- |
pdf_text |
| 7 |
7. Chapter 8, Roof-Ceiling Construction, shall be amended as follows:
i. In Section R802.10.1, entitled "Truss Design Drawings," the third sentence shal
amended to insert "and truss layout drawings" after "Truss design drawings."
ii. New Section R802.10.5, entitled "Truss Identification," shall be inserted as foll
"Each truss shall be labeled or otherwise indelibly marked at the factory with the i
truss number as assigned in the truss layout plan. The indelible marking or label sh
located on the bottom chord of the truss, inside the bearing points. When indelible
markings are used, each digit shall be not less than one inch high. When labels are
the label shall be a minimum of five inches by three inches and shall be affixed to
by a truss plate. Labels shall remain affixed to the truss." |
- |
pdf_text |
| 7 |
7. Chapter 7, Fire and Smoke Protection Features, shall be amended as follows:
i. In Section 703.2.3, Approved alternate protection, is amended to delete "Section
and insert "N.J.A.C. 5:23-3.7" in its place.
ii. In Section 705.2.3, Projection protection, in the exception, "and U" shall be del |
- |
pdf_text |
| 7 |
7. Chapter 9 of the mechanical subcode, entitled "Specific Appliances, Fireplaces and
Fuel Burning Equipment," shall be amended as follows:
i. In Section 923.1, Small ceramic kilns, "Section 105.2" shall be deleted in two lo
and "N.J.A.C. 5:23-3.7" shall be inserted. |
- |
pdf_text |
| 7 |
7. Under the heading of "Subject to damage from - Weathering," insert "Sever |
- |
pdf_text |
| 7 |
7. Wastewater treatment tanks; |
- |
pdf_text |
| 7 |
7:14B.
History
HISTORY:
Amended by R.1990 d.562, effective November 19, 1990.
See: 22 New Jersey Register 2629(c), 22 New Jersey Register 3482(d).
Added reference to N.J.A.C. 7:14B.
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| 7 |
7. Chapter 7 of the plumbing subcode, entitled "Plumbing Fixtures, Fixture Fittings a
Plumbing Appliances," shall be amended as follows:
i. Section 7.2, Fixtures For Accessible Use, subsection a. shall be deleted and the
following shall be inserted: "Plumbing fixtures for accessible use and their installa
shall conform to the requirements of Chapter 11 of the building subcode (N.J.A.C. |
- |
pdf_text |
| 7 |
7. Chapter 6 of the electrical subcode, entitled "Special Equipment," is amended, as f
i. In Section 620.1, Scope, Informational Note No. 1 shall have "ASME A17.1-20
B44-16" deleted and "ASME A17.1-2019/CSA B44-19" shall be inserted in its pla
ii. In Section 620.23(C), Duplex Receptacle, the Informational Note shall have "A
A17.1-2016/CSA B44-16" deleted and "ASME A17.1-2019/CSA B44-19" shall be
in its place;
iii. In Section 620.24(C), Duplex Receptacle, Informational Note No. 1 shall have
A17.1-2016/CSA B44-16" deleted and "ASME A17.1-2019/CSA B44-19" shall be
in its place;
iv. In Section 620.51(A), Type, the Informational Note shall have "ASME A17.1- |
- |
pdf_text |
| 7 |
7
Gaseous Hydrogen
Systems |
- |
pdf_text |
| 7 |
7
Combustion Air
Fire
Fire
Ch. |
- |
pdf_text |
| 7 |
7:14B, shall be a prior approval for any permit application submitted pursuant to the State
Construction Code Act and these rules. Applicants installing secondarily contained system
which no prior DEP approval is necessary shall be required to submit engineering drawin
secondarily contained systems and to certify that the underground storage tank system me
requirements of N.J.A.C. 7:14B.
(c) Construction code officials shall retain all penalty powers, as set forth in these rules,
respect to the installation, usage or closure (demolition) of underground storage tank syste
parts thereof in violation of the State Uniform Construction Code Act or these rules.
(d) The following types of underground storage tank systems requiring a construction per
exempt from the requirements of N.J.A.C. 7:14B: |
- |
pdf_text |
| 7 |
7. Chapter 7 of the fuel gas code, entitled "Gaseous Hydrogen Systems," shall be ame
follows:
i. In Section 701.2, Permits, "Section 106" shall be deleted, and "the administrativ
provisions of the Uniform Construction Code" shall be inserted in its place. |
- |
pdf_text |
| 7 |
7. Chapter 6 of the electrical subcode, entitled "Special Equipment," is amended, as f
i. Article 680.4, Inspections after installation, shall be deleted. |
- |
pdf_text |
| 7 |
7
Fire and Smoke
Building/Fire
Building
Protection Systems
(Except penetrations in
existing membranes for
electrical outlets or devices
pursuant to Section 714.4.2
which shall be Electrical)
C
h. |
- |
pdf_text |
| 7 |
7
Service Water
As applicable
As applicable
Heating |
- |
pdf_text |
| 7 |
7. Chapter 9 of the mechanical subcode, entitled "Specific Appliances, Fireplaces and
Fuel Burning Equipment," shall be amended as follows: |
- |
pdf_text |
| 7 |
7
Fire and Smoke
Building/Fire
Building
Protection Systems
(Except penetrations in
existing membranes for
electrical outlets or
devices pursuant to Section |
- |
pdf_text |
| 7 |
7. All premanufactured systems for Class 1 and Class 2 structures, other than those au
to be approved by an inplant inspection agency licensed to perform Class 1 and Class
review as provided in N.J.A.C. 5:23-4A.7, and all on-site installation of Class 1 and C
premanufactured construction within the jurisdiction of a local enforcing agency that i
Class 1 or Class 2 agency, as the case may be. |
- |
pdf_text |
| 7 |
7:14B.
History
HISTORY:
Amended by R.1990 d.562, effective November 19, 1990.
See: 22 New Jersey Register 2629(c), 22 New Jersey Register 3482(d).
Added reference to N.J.A.C. 7:14B.
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| 7 |
7. Fuel Gas Subcode:
Cha
pter
Section/Title
Responsibility
Plan Review
Inspection
Ch. |
- |
pdf_text |
| 7 |
7
Wall Covering
Building
Building
Ch. |
- |
pdf_text |
| 7 |
7
Service Water
As applicable
As applicable
Heating
Ch. |
- |
pdf_text |
| 7 |
7
Plumbing Fixtures, Fixture Fittings
Plumbi
ng
Plumbing
and Plumbing Appliances
C
h. |
- |
pdf_text |
| 7 |
7
Plumbing Fixtures, Fixture Fittings
Plumbi
ng
Plumbing
and Plumbing Appliances
C
h. |
- |
pdf_text |
| 7 |
7. Procedures for adoption of future subcode amendments.
(d) This subchapter provides a uniform system of construction standards throughout the S
through the adoption of model codes applicable throughout the State. Modifications made |
- |
pdf_text |
| 7 |
7. Appendices
i. Appendix RA, Board of Appeals--Residential, is deleted.
ii. Appendix RB, Solar-Ready Provisions--Detached One- and Two-Family Dwell
Townhouse, is optional at the discretion of the permit applicant.
iii. Appendix RC, Zero Energy Residential Building Provisions, is optional at the
discretion of the permit applicant. Appendix RC shall be amended as follows:
(1) In Section RC101.1, Compliance, "Existing residential buildings shall com
Chapter 5." is deleted.
History
HISTORY:
Amended by R.1987 d.387, effective October 5, 1987.
See: 19 N.J.R. 433(b), 19 N.J.R. 1793(a).
Substantially amended. |
- |
pdf_text |
| 7 |
7. Chapter 7, Fire and Smoke Protection Features, shall be amended as follows:
i. In Section 705.2.3, Projection protection, in the exception, "and U" shall be dele |
- |
pdf_text |
| 7 |
7. Appendices
i. Appendix CA, Board of Appeals--Commercial, is deleted.
ii. Appendix CB, Solar-Ready Zone, is optional at the discretion of the permit app
except that this appendix is adopted as a requirement for the construction of a ware
for which a construction permit has not been declared complete by the enforcing a |
- |
pdf_text |
| 7 |
7. Appendices
i. Appendix CA, Board of Appeals--Commercial, is deleted.
ii. Appendix CB, Solar-Ready Zone, is optional at the discretion of the permit app
except that this appendix is adopted as a requirement for the construction of a ware
for which a construction permit has not been declared complete by the enforcing a
before July 1, 2022, pursuant to P.L. 2021, c. 290. A warehouse means any buildin
structure, or facility of at least 100,000 square feet used primarily for the storage o
intended for sale.
iii. Appendices CC, Zero Energy Commercial Building Provisions; CD, The 2030
Path; CE, Required HVAC Total System Performance Ratio; CF, Energy Credits;
Electric Vehicle Charging Infrastructure; CH, Electric-Ready Commercial Buildin
Provisions; CI, Demand Responsive Controls; and CJ, Electrical Energy Storage S
are optional at the discretion of the permit applicant. |
- |
pdf_text |
| 7 |
7. The type and amount of materials or supplies stored in a commercial farm building,
including hay, straw, and livestock bedding materials, shall not be subject to limitation
However, other hazardous materials within spaces of commercial farm buildings occu
more than 10 persons shall not exceed the allowable exempt amounts shown in Tables |
- |
pdf_text |
| 7 |
7
Gaseous Hydrogen
Systems |
- |
pdf_text |
| 7 |
7
Ch.
Roof-Ceiling
Building
Building |
- |
pdf_text |
| 7 |
7. In Section 410.5.2.2, Existing buildings, shall be amended to add the follow
phrase after the words "in existing buildings," "where technically infeasible to
the door arrangement prescribed by Section 410.5.2.1." |
- |
pdf_text |
| 7.23.1 |
7.23.1, Suction Entrapment Avoidance. Suction outlets shall be designed and
in accordance with ANSI/PHTA/ICC-7."
xiii. In Table 7.21.1, in the second column entitled "Occupancy Group," "R-2: On
two-family dwellings" shall be deleted and "R-3/R-5: One- and two-family dwelli
shall be inserted.
xiv. In Note 1 to Table 7.21.1, Minimum Number of Required Plumbing Fixtures,
the second sentence. |
- |
pdf_text |
| 7.23.1 |
7.23.1, Suction Entrapment Avoidance. Suction outlets shall be designed a
installed in accordance with ANSI/PHTA/ICC-7." |
- |
pdf_text |
| 7.5.3 |
7.5.3, "Protecting Surrounding Surfaces of Urinals."
vi. In Section 7.11.4, Service Sinks and Mop Receptors, b. is amended to delete th
following after "surface," "at least one foot in front of the sink or receptor, at least
on each side, and up to a point one foot above the faucet height," and insert, "refer
International Building Code, Section 1210.2.2."
vii. In Section 7.21.2, Occupant Load, b. "building code" shall be deleted and "bui
subcode" shall be inserted.
viii. In Section 7.21.9, Family and Assisted-Use Toilet Rooms, "applicable buildi
shall be deleted and "building subcode" shall inserted.
ix. Section 7.23, Safety Features for Spas and Hot Tubs, shall be deleted and Secti
Safety Features for Spas and Hot Tubs, shall be inserted as follows:
"7.23 Safety Features for Swimming Pools, Spas, and Hot Tubs. |
- |
pdf_text |
| 7.9 |
7.9 and 7.10". In addition, under the subheading standard delete ASME A17.7/CS
iii. In Section 3001.5, Change in use, "Section 8.7 of ASME A17.1/CSA B44" sh
deleted and "ASME A17.1" shall be inserted. |
- |
pdf_text |
| 7.9 |
7.9 and 7.10". In addition, under the subheading standard delete ASME A17.7/CS
iv. In Section 3001.5, Change in use, "Section 8.7 of ASME A17.1/CSA B44" sha
deleted and "ASME A17.1" shall be inserted.
v. In Section 3002.5, Emergency doors, "ASME A17.1/CSA B44" shall be delete
"ASME A17.1" shall be inserted.
vi. In Section 3002.9, Plumbing and mechanical systems, in the exception, "witho
water separator" shall be inserted at the end of the sentence. In addition, the follow
sentence shall be inserted: "The discharge shall not be directly or indirectly connec
the sanitary drainage system."
vii. In Section 3003.1.3, Two or more elevators, the last sentence shall be deleted
following sentence shall be substituted "After all elevators have been returned to t
designated level, service to all floors shall be provided by not less than one elevato
shall remain operational from the standby power source."
viii. In Section 3003.2, Fire-fighters' emergency operation, "ASME A17.1/CSA B
be deleted and "ASME A17.1" shall be inserted.
ix. In Section 3003.3, Standardized fire service elevator keys, "International Fire
shall be deleted and "Elevator Safety Subcode (N.J.A.C. 5:23-12)" shall be inserte
x. In Section 3005.6, Plumbing systems, add the following exception:
"Exception: Where machinery spaces and control spaces are located in the elev
floor drains, sumps and sump pumps shall be permitted in the pits provided the
indirectly connected to the plumbing system without an oil-water |
- |
pdf_text |
| 7.9 (cont. 2) |
separator. Th
discharge shall not be directly or indirectly connected to the sanitary system." |
- |
pdf_text |
| 700-726 |
700-726
Electrical
Electrical |
- |
pdf_text |
| 700-727 |
700-727
Electrical
Electrical |
- |
pdf_text |
| 702.1 |
702.1
Electrical/Fire
Electrical |
- |
pdf_text |
| 703.1 |
703.1
Building
Building |
- |
pdf_text |
| 703.1 |
703.1
Buildin
g
Building |
- |
pdf_text |
| 703.1-907.1 |
703.1-907.1
Building
Building |
- |
pdf_text |
| 703.2 |
703.2
Building/Fire
Fire |
- |
pdf_text |
| 703.2 |
703.2
Buildin
g/Fire
Fire |
- |
pdf_text |
| 703.3-703.5 |
703.3-703.5
Fire
Fire |
- |
pdf_text |
| 703.3-703.5 |
703.3-703.5
Fire
Fire |
- |
pdf_text |
| 703.6 |
703.6
Electrical
Electrical |
- |
pdf_text |
| 703.6 |
703.6
Electric
al
Electrical |
- |
pdf_text |
| 704.1 |
704.1
Fire
Fire |
- |
pdf_text |
| 704.1 |
704.1
Fire
Fire |
- |
pdf_text |
| 704.1.1 |
704.1.1
Fire
Fire |
- |
pdf_text |
| 704.1.1 |
704.1.1
Fire
Fire |
- |
pdf_text |
| 704.1.2 |
704.1.2
Plumbing
Plumbing |
- |
pdf_text |
| 704.1.2 |
704.1.2
Plumbi
ng
Plumbing |
- |
pdf_text |
| 704.2-704.4 |
704.2-704.4
Fire
Fire |
- |
pdf_text |
| 704.2-704.4 |
704.2-704.4
Fire
Fire |
- |
pdf_text |
| 705 |
705
Plumbing
Plumbing |
- |
pdf_text |
| 705 |
705
Plumbi
ng
Plumbing |
- |
pdf_text |
| 705.5 |
705.5 of the building subcode must be maintained between a commercial farm buil
any building not eligible for the commercial farm building exemption. |
- |
pdf_text |
| 706.1 |
706.1
Building
Building |
- |
pdf_text |
| 706.1 |
706.1
Buildin
g
Building |
- |
pdf_text |
| 706.2 |
706.2
Buildin
g/Fire
Fire |
- |
pdf_text |
| 706.2 |
706.2
Building/Fire
Fire |
- |
pdf_text |
| 706.3 |
706.3
Fire
Fire |
- |
pdf_text |
| 706.3 |
706.3
Fire
Fire |
- |
pdf_text |
| 707-708 |
707-708
Fire
Fire |
- |
pdf_text |
| 707-708 |
707-708
Fire
Fire |
- |
pdf_text |
| 714.4.2 |
714.4.2 which shall be |
- |
pdf_text |
| 72 |
72,000
*
*
(36,000
per floor) |
- |
pdf_text |
| 728 |
728
Fire/Electrical
Electrical |
- |
pdf_text |
| 728 |
728
Fire/Electrical
Electrical |
- |
pdf_text |
| 743 |
743 (A.D.1992).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| 750 |
750
Electrical
Electrical |
- |
pdf_text |
| 750 |
750
Electrical
Electrical |
- |
pdf_text |
| 760 |
760
Electrical/Fire
Electrical |
- |
pdf_text |
| 760 |
760
Electrical/Fire
Electrical |
- |
pdf_text |
| 770 |
770
Electrical
Electrical
Ch. 8
Communication Systems
Electrical
Electrical
Ch. 9
Tables
Electrical
Electrical |
- |
pdf_text |
| 770 |
770
Electrical
Electrical
Ch. 8
Communication Systems
Electrical
Electrical
Ch. 9
Tables
Electrical
Electrical |
- |
pdf_text |
| 8 |
8. Chapter 8 of the fuel gas code, entitled "Referenced Standards," shall be amended a
follows:
i. Under the heading "ICC," amend the following titles:
(1) Delete "IPC--21, International Plumbing Code." |
- |
pdf_text |
| 8 |
8. Chapter 8 of the electrical subcode, entitled "Communication Systems," is amende
follows:
i. Section 805.156, entitled "Dwelling Unit Communications Outlet," is deleted in
entirety. |
- |
pdf_text |
| 8 |
8. Chapter 9, Roof Assemblies, shall be amended as follows:
i. In Section R903.4.1, Secondary (emergency overflow) drains or scuppers, in the
sentence of the first paragraph, "Sections 1106 and 1108 of the International Plum
Code, as applicable" shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)
inserted in its place.
ii. In Section R905.1.2, Ice barriers, in the first sentence, delete "in areas where th
been a history of ice forming along the eaves causing a back-up of water as design
table R301.2," and "In areas where the average daily temperature in January is 25⁰
or less," shall be inserted. |
- |
pdf_text |
| 8 |
8
Interior Finishes
Building/Fire
Building
Ch. |
- |
pdf_text |
| 8 |
8. Delete section 502.9, "On-street parking spaces" in its entirety; |
- |
pdf_text |
| 8 |
8. Chapter 9, Fire Protection and Life Safety Systems, shall be amended as follows:
i. In Section 901.3, Modifications, "remove or" shall be deleted. Additionally, "bu
official" shall be deleted and "fire protection subcode official" shall be inserted.
ii. In Section 901.5, Acceptance test, in the second sentence, "building official" sh
deleted and "fire protection subcode official" shall be inserted. |
- |
pdf_text |
| 8 |
8
Interior Finishes
Building/Fire
Building
C
h. |
- |
pdf_text |
| 8 |
8
Hangers and Supports
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 8 |
8. Battery calculations. |
- |
pdf_text |
| 8 |
8. Chapter 10 of the mechanical subcode, entitled "Boilers, Water Heaters and Pressu
Vessels," shall be amended as follows:
i. Section 1001.1, Scope, is amended to replace the words "installation, alteration,
repair of boilers," with the words "installation and alteration of boilers."
ii. Section 1002.4, Water heater pan required, shall be deleted. |
- |
pdf_text |
| 8 |
8. Under the heading of "Subject to damage from - Frost line depth," insert "2' |
- |
pdf_text |
| 8 |
8
Power
Electrical
Electrical
Ch. |
- |
pdf_text |
| 8 |
8
Chimneys and Vents
Building/Fire
Fire (except 801.3
and 801.13) |
- |
pdf_text |
| 8 |
8. Health care facilities, as defined at N.J.A.C. 5:23-1.4; |
- |
pdf_text |
| 8 |
8
Hangers and Supports
Plumbi
ng
Plumbing
C
h. |
- |
pdf_text |
| 8 |
8. Chapter 8 of the plumbing subcode, entitled "Hangers and Supports," shall be amen
follows:
i. In Section 8.9, Seismic Supports for Piping, "code" shall be deleted and "subcod
be inserted. |
- |
pdf_text |
| 8 |
8. Electrical equipment; |
- |
pdf_text |
| 8 |
8. Chapter 9, Roof Assemblies, shall be amended as follows:
i. In Section R903.4.1, Secondary (emergency overflow) drains or scuppers, in the
sentence of the first paragraph, "Sections 1106 and 1108 of the International Plum
Code, as applicable" shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)
inserted in its place. |
- |
pdf_text |
| 8 |
8
Power
Electrical
Electrical
Ch. |
- |
pdf_text |
| 8 |
8
Roof-Ceiling
Building
Building
Construction
Ch. |
- |
pdf_text |
| 8 |
8. Chapter 9, Fire Protection Systems, shall be amended as follows:
i. In Section 901.3, Modifications, "remove or" shall be deleted. Additionally, "bu
official" shall be deleted and "fire protection subcode official" shall be inserted. |
- |
pdf_text |
| 8 |
8. Chapter 7 of the electrical subcode, entitled "Energy Storage Systems" shall be am
follows:
i. Section 706.7, Commissioning and Maintenance, is deleted in its entirety. |
- |
pdf_text |
| 8 |
8. Chapter 8 of the fuel gas code, entitled "Referenced Standards," shall be amended a
follows:
i. At the heading "ICC," amend the following titles:
(1) At "IBC-24", insert ", as adopted at N.J.A.C. 5:23-3.14, building subcode"
"Code.".
(2) At "IECC-24", insert ", as adopted at N.J.A.C. 5:23-3.18, energy subcode"
"Code.".
(3) At "IMC-24", insert ", as adopted at N.J.A.C. 5:23-3.20, mechanical subco
"Code.". |
- |
pdf_text |
| 8 |
8
Construction
Ch.
Roof
Building
Building |
- |
pdf_text |
| 8 |
8. Elevator Subcode: All (except as provided for in N.J.A.C. 5:23-12) |
- |
pdf_text |
| 8 |
8
Chimneys and Vents
Building/Fire
Fire (except 801.3
and 801.13) |
- |
pdf_text |
| 8 |
8. A commercial farm building may be used as a place of public assembly for not mor |
- |
pdf_text |
| 8 |
8. Chapter 8 of the plumbing subcode, entitled "Hangers and Supports," shall be amen
follows: |
- |
pdf_text |
| 8 |
8 sign from the Manual of Uniform Traffic Control Devices and shall display t
international symbol of accessibility. Beneath the R7-8 sign, each accessible p
space shall also be marked with a penalty sign, as required by N.J.S.A. 39:4-19
containing the following language:
PENALTY
$ 250 FIRST OFFENSE
SUBSEQUENT OFFENSES
$ 250 MINIMUM AND/OR
UP TO 90 DAYS COMMUNITY SERVICE
TOW AWAY ZONE |
- |
pdf_text |
| 8 |
8. Elevator Subcode: All (except as provided for in N.J.A.C. 5:23-12 ) |
- |
pdf_text |
| 8 |
8. Chapter 10 of the mechanical subcode, entitled "Boilers, Water Heaters and Pressu
Vessels," shall be amended as follows:
i. Section 1001.1, Scope, is amended to replace the words "installation, alteration,
repair of boilers," with the words "installation and alteration of boilers."
ii. In Section 1002.1, General, in the first and third sentence, "International Plumb
Code," shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inse
iii. In Section 1002.2, Water heaters utilized for space heating, "International Plu
Code," shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inse
iv. Section 1002.3, Supplemental water-heating devices, "International Plumbing
shall be deleted and "plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
v. In Section 1008.2, Discharge, "International Plumbing Code," shall be deleted a
"plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| 801.3 |
801.3 and 801.13
Building/Fire
Building
Ch. |
- |
pdf_text |
| 801.3 |
801.3 and 801.13
Building/Fire
Building
Ch. |
- |
pdf_text |
| 804.5.4 |
804.5.4, entitled "Cooktop," 804.5.5, entitled "Oven," and 804.5.6, entitled
"Refrigerator/Freezer," shall be deleted in their entirety. |
- |
pdf_text |
| 9 |
9. Chapter 11 of the mechanical subcode, entitled "Refrigeration," is amended as follo
i. Section 1101.1, Scope, the words "and repair" shall be deleted.
ii. Section 1102.2.2, Purity, is deleted in its entirety.
iii. Add new Section 1103.1.1, Acceptable refrigerants, as follows: "Only refriger
listed by the US Environmental Protection Agency (EPA), pursuant to the Signific
Alternatives Program (SNAP) under section 612 of the Clean Air Act Amendment
those listed by the NJ Department of Environmental Protection (DEP) pursuant to
Pollution Control Act, P.L. 1954, c. 212 (N.J.S.A. 26:2C‐1 et seq.), as acceptable
substitutes for the particular use shall be permitted."
iv. Section 1111, Periodic testing, is deleted. |
- |
pdf_text |
| 9 |
9. Chapter 10, Means of Egress, shall be amended as follows:
i. In Section 1003.2, Ceiling height, "7 feet 6 inches (2286 mm)" shall be deleted
feet (2134 mm)" shall be inserted.
ii. In Section 1004.5, Areas without fixed seating, the exception shall be deleted i
entirety.
iii. In Table 1004.5, MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPA
the first column, FUNCTION OF SPACE, 44th row, delete "swimming pools," 45
delete "pool," and 46th row, delete "Decks;" in the second column, OCCUPANT
FACTOR, 46th row, delete "15 gross."
iv. In Section 1004.5.1, Increased occupant load, "7 square feet (.65 m2)" shall be
and "5 square feet (.47 m2)" shall be inserted.
v. In Section 1006.2.2.6, Groups R-3 and R-4, the title shall be deleted and the fol
shall be inserted: "Group R-4". Additionally, the first sentence of the section shall
deleted.
vi. In Table 1006.2.1, Spaces with one exit or exit access doorway, in the 5th colu
the 10th row (R-3), the reference to footnote a and g shall be deleted; and in footn |
- |
pdf_text |
| 9 |
9. Chapter 11 of the mechanical subcode, entitled "Refrigeration," is amended as follo
i. Section 1101.1, Scope, the words "and repair" shall be deleted.
ii. Section 1102.2.2, Purity, is deleted in its entirety.
iii. Add new Section 1103.1.1, Acceptable refrigerants, as follows: "Only refriger
listed by the US Environmental Protection Agency (EPA), pursuant to the Signific
Alternatives Program (SNAP) under section 612 of the Clean Air Act Amendment
those listed by the NJ Department of Environmental Protection (DEP) pursuant to |
- |
pdf_text |
| 9 |
9. Buildings containing any of the following uses are not included in the definition of
commercial farm building:
i. Residential structures;
ii. High hazard facilities, such as grain elevators or grain storage silos used to stor
products which are neither used nor produced on the farm itself;
iii. Processing facilities that include specialized machinery to perform functions o
the washing, cleaning, hydrocooling, vacuum cooling, grading, sizing and packing
agricultural or horticultural products, unless the exempted functions are only the fi
in a sequence of processing to be performed on the farm;
iv. Mercantile structures, such as farm retail markets or nursery greenhouse retail
areas; |
- |
pdf_text |
| 9 |
9
Fire Protection
Systems |
- |
pdf_text |
| 9 |
9. Chapter 10, Chimneys and Fireplaces, shall be amended as follows:
i. In Section R1001.11, Fireplace clearance, Exception 3, "12 inches" shall be dele
"six inches" shall be inserted. In addition, in Figure R1001.11, Clearance from
combustibles, "12 IN." shall be deleted and "6 IN." shall be inserted.
ii. In Section R1003.18, Chimney clearances, Exception 3, "8 inches" shall be del
"six inches" shall be inserted. |
- |
pdf_text |
| 9 |
9. Chapter 10, Means of Egress, shall be amended as follows:
i. In Section 1003.2, Ceiling height, "7 feet 6 inches (2286 mm)" shall be deleted
feet (2134 mm)" shall be inserted.
ii. In Section 1004.5, Areas without fixed seating, the exception shall be deleted i
entirety.
iii. In Table 1004.5, MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPA
the first column, FUNCTION OF SPACE, 43rd row, delete "swimming pools," 44
delete "pool," and 45th row, delete "Decks;" in the second column, OCCUPANT
FACTOR, 45th row, delete "15 gross."
iv. In Section 1004.5.1, Increased occupant load, "7 square feet (.65 m<2>)" shall
deleted and "5 square feet (.47 m<2>)" shall be inserted.
v. In Section 1006.2.2.6, Groups R-3 and R-4, the title shall be deleted and the fol
shall be inserted: "Group R-4". Additionally, the first sentence of the section shall
deleted.
vi. In Table 1006.2.1, Spaces with one exit or exit access doorway, in the 5th colu
the 10th row (R-3), the reference to footnote a and g shall be deleted; and in footn |
- |
pdf_text |
| 9 |
9. Radon Hazard Subcode: Plan review and inspection with regard to compliance wit
N.J.A.C. 5:23-10.4(b) and (c) shall be the responsibility of the building subcode offici |
- |
pdf_text |
| 9 |
9. Radon Hazard Subcode: Plan review and inspection with regard to compliance wit
N.J.A.C. 5:23-10.4(b) and (c) shall be the responsibility of the building subcode offici
except that N.J.A.C. 5:23-10.4(b)13 and (c)14 shall be the responsibility of the electric
subcode official.
(b) Where responsibility for enforcement of a section is joint between two officials and th
conflicting opinions regarding enforcement, the construction official shall rule as to which
interpretation or application shall be followed.
(c) Responsibility for enforcement of the Radon Hazard Subcode shall be in accordance
N.J.A.C. 5:23-10.3.
(d) Any mechanical inspector employed by the Department or by a municipality, and so a
by the construction official, shall have the responsibility for enforcement of the provisions
code for the installation and replacement of heating or cooling equipment or water heaters
mechanical equipment, such as refrigeration, air conditioning, or ventilating apparatus, ga
or heating systems, or stand-by power generators, except work involving the installation o |
- |
pdf_text |
| 9 |
9
Specific Appliances,
Fireplaces and Solid
Fuel-Burning Equipment |
- |
pdf_text |
| 9 |
9
Indirect Waste Piping and Special
Plumbi
ng
Plumbing
Wastes
C
h.
Water Supply and Distribution
Plumbi
ng
Plumbing |
- |
pdf_text |
| 9 |
9. Chapter 10 of the plumbing subcode, entitled "Water Supply and Distributions," sh
amended as follows:
i. In Section 10.4.2, Interconnections, delete "with the approval of the Authority H
Jurisdiction" and insert "in accordance with the rules of the New Jersey Departme
Environmental Protection at N.J.A.C. 7:10-10."
ii. In Section 10.4.3, Cross Connection Control, the text shall be deleted and the f
shall be inserted "Potable water supplies shall be protected in accordance with the
provisions of this code and where applicable the Safe Drinking Water Regulations
(N.J.A.C. 7:10). The requirements of this code shall establish requirements for ind
outlet protection. The requirements of the Safe Drinking Water Act shall establish
requirements for containment." |
- |
pdf_text |
| 9 |
9. Under the heading of "Subject to damage from - Termite," insert "Moderate
Heavy"; |
- |
pdf_text |
| 9 |
9
Lighting
Electrical
Electrical
Ch. |
- |
pdf_text |
| 9 |
9. Delete section 502.10.1, "Location" in its entirety; |
- |
pdf_text |
| 9 |
9. Chapter 8 of the electrical subcode, entitled "Communication Systems," is amende
follows: |
- |
pdf_text |
| 9 |
9. Conductor type and sizes. |
- |
pdf_text |
| 9 |
9. Public school facilities, as defined in N.J.A.C. 5:23-1.4; |
- |
pdf_text |
| 9 |
9. Hydraulic lift tanks; and |
- |
pdf_text |
| 9 |
9. Appendices A, B, and C of the fuel gas subcode are informative and are not part of
subcode itself. |
- |
pdf_text |
| 9 |
9
Assemblies,
except
R905.16-R905.17
and R907.1
R905.16-R905.17
Building/Electrical
Building
R907.1
As applicable
As applicable
Ch.
Chimneys and
Building/Fire
Building |
- |
pdf_text |
| 9 |
9
Indirect Waste Piping and Special
Plumbi
ng
Plumbing
Wastes
C
h.
Water Supply and Distribution
Plumbi
ng
Plumbing |
- |
pdf_text |
| 9 |
9. Appendices A and B of the fuel gas subcode are informative and are not part of the
itself. |
- |
pdf_text |
| 9 |
9
Fire Protection
Systems |
- |
pdf_text |
| 9 |
9. Informative Annex H of the electrical subcode, entitled "Administration and Enfor
is deleted in its entirety.
History
HISTORY:
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1984 d.314, effective August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b).
Section substantially amended.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1990 d.253, effective May 21, 1990. |
- |
pdf_text |
| 9 |
9
Lighting
Electrical
Electrical
Ch. |
- |
pdf_text |
| 9 |
9. Chapter 10 of the plumbing subcode, entitled "Water Supply and Distributions," sh
amended as follows:
i. In Section 10.4.2, Interconnections, delete "with the approval of the Authority H
Jurisdiction" and insert "in accordance with the rules of the New Jersey Departme
Environmental Protection at N.J.A.C. 7:10-10."
ii. In Section 10.4.3, Cross Connection Control, the text shall be deleted and the f
shall be inserted "Potable water supplies shall be protected in accordance with the
provisions of this code and where applicable the Safe Drinking Water Regulations
(N.J.A.C. 7:10). The requirements of this code shall establish requirements for ind
outlet protection. The requirements of the Safe Drinking Water Act shall establish
requirements for containment."
iii. In Section 10.4.4b, Private Supplies, "in accordance with N.J.A.C. 7:10-10.2(e
be inserted after "Authority Having Jurisdiction."
iv. In Section 10.5.6e, Testing and Maintenance of Backflow Prevention Assembl
repair" shall be deleted. Additionally, in the same sentence, "approved by an agenc
acceptable to the Authority Having Jurisdiction" shall be deleted.
v. Section 10.5.9a, Protection from Fire Systems, Exception (4) shall be deleted a
following inserted: "(4) Where fire protection systems supplied from a potable wat
system include a fire department connection which is located less than 1,700 feet f
non-potable water source, the water supply shall be protected by one of the followi
(i) Reduced pr |
- |
pdf_text |
| 9 |
9. Chapter 10, Chimneys and Fireplaces, shall be amended as follows:
i. In Section R1001.11, Fireplace clearance, Exception 3, "12 inches" shall be dele
"six inches" shall be inserted. In addition, in Figure R1001.11, Clearance from
combustibles, "12 IN." shall be deleted and "6 IN." shall be inserted.
ii. In Section R1003.18, Chimney clearances, Exception 3, "8 inches" shall be del
"six inches" shall be inserted.
iii. In Figure R1003.18, Clearance from Combustibles, "8 IN." shall be deleted an
shall be inserted. |
- |
pdf_text |
| 9 |
9
Specific Appliances,
Fireplaces and Solid
Fuel-Burning Equipment |
- |
pdf_text |
| 9 |
9
Roof
Building
Building
Assemblies, except
R905.15-R905.16
and R907.1
Building/Electrical
Building
R905.15-R905.16
R907.1
As applicable
As applicable
Ch. |
- |
pdf_text |
| 9 (cont. 2) |
essure backflow preventer assembly; or
(ii) Reduced pressure detector assembly."
vi. In Section 10.8.1, Water Pressure Booster Systems Required, "and in accordan
good practice" in the fifth and sixth lines shall be deleted. |
- |
pdf_text |
| 90 |
90
Ch. 1
General
Electrical
Electrical
Ch. 2
Wiring and Protection |
- |
pdf_text |
| 90 |
90
Ch. 1
General
Electrical
Electrical
Ch. 2
Wiring and Protection |
- |
pdf_text |
| 90.1 |
90.1
Cha
pter
Section/Title
Responsibility
Plan Review
Inspection
AS
HR
AE |
- |
pdf_text |
| 901.1-903.3.1.2.3 |
901.1-903.3.1.2.3#3.1
Fire
Fire |
- |
pdf_text |
| 901.1-903.3.1.2.3 |
901.1-903.3.1.2.3#3.1
Fire
Fire |
- |
pdf_text |
| 901.1-908.4 |
901.1-908.4
Building/Fire
Building |
- |
pdf_text |
| 901.1-908.4 |
901.1-908.4
Building/Fire
Building |
- |
pdf_text |
| 903.3.1.1 |
903.3.1.1, each riser shall be sized for a minimum flow of 250 gpm (94
L/min.). |
- |
pdf_text |
| 903.3.1.1 |
903.3.1.1, all common supply piping shall be sized for a minimum flow
gpm (945 L/min.) for the first riser plus 250 gpm (945 L/min.) for each
additional riser, and the total shall not be required to exceed 750 gpm (
L/min.). |
- |
pdf_text |
| 903.3.1.1 |
903.3.1.1, each riser shall be sized for a minimum flow of 250 gpm (945 L/ |
- |
pdf_text |
| 903.3.1.1 |
903.3.1.1, all common supply piping shall be sized for a minimum flow of
(945 L/min.) for the first riser plus 250 gpm (945 L/min.) for each addition
and the total shall not be required to exceed 750 gpm (2838 L/min.). |
- |
pdf_text |
| 903.3.1.1 |
903.3.1.1 when the maximum area is exceeded for the following construction type
Groups B, F-2, and S-2 in accordance with Table 903.2.13, Automatic Sprinkler S
Thresholds. All others not listed shall follow the applicable requirements as set for
code.
Automatic Sprinkler System Thresholds
Group B
IIB
IIIB
VB
Story
Max. Area
Max. Area
Max. Area |
- |
pdf_text |
| 903.3.1.1 |
903.3.1.1 or 903.3.1.2 and also where the highest floor level is not more than
(45720 mm) above the lowest level of fire department vehicle access. |
- |
pdf_text |
| 903.3.1.2.3 |
903.3.1.2.3#3.2-#3.4
Building/Fire
Building |
- |
pdf_text |
| 903.3.1.2.3 |
903.3.1.2.3#4-#4.2
Fire
Fire |
- |
pdf_text |
| 903.3.1.2.3 |
903.3.1.2.3#4.3-#4.5
Building/Fire
Building |
- |
pdf_text |
| 903.3.1.2.3 |
903.3.1.2.3#4.3-#4.5
Building/Fire
Building |
- |
pdf_text |
| 903.3.1.2.3 |
903.3.1.2.3#3.2-#3.4
Building/Fire
Building |
- |
pdf_text |
| 903.3.1.2.3 |
903.3.1.2.3#4-#4.2
Fire
Fire |
- |
pdf_text |
| 903.3.1.3-904.3 |
903.3.1.3-904.3
Fire
Fire |
- |
pdf_text |
| 903.3.1.3-904.3 |
903.3.1.3-904.3
Fire
Fire |
- |
pdf_text |
| 903.5.1 |
903.5.1 Flow test: All systems shall be tested at the test pipe to determine that
flow detecting devices, including the associated alarm circuits, are in proper w
order. Dry pipe systems shall deliver water to the inspector's test pipe in not m |
- |
pdf_text |
| 903.5.1 |
903.5.1 Flow test: All systems shall be tested at the test pipe to determine that
flow detecting devices, including the associated alarm circuits, are in proper w
order. Dry pipe systems shall deliver water to the inspector's test pipe in not m |
- |
pdf_text |
| 903.5.2 |
903.5.2 Limited area sprinkler system acceptance test. All limited area sprinkle
systems, which are not connected to a building standpipe system, shall be teste
hydrostatically for a minimum of 15 minutes without visible leakage at the wor
pressure under which the system is to be used. Limited area sprinkler systems,
are connected to a building standpipe system, shall be tested in accordance wit |
- |
pdf_text |
| 903.5.2 |
903.5.2 Limited area sprinkler system acceptance test. All limited area sprinkl
systems, which are not connected to a building standpipe system, shall be teste
hydrostatically for a minimum of 15 minutes without visible leakage at the wor
pressure under which the system is to be used. Limited area sprinkler systems,
are connected to a building standpipe system, shall be tested in accordance wit |
- |
pdf_text |
| 904.3.1 |
904.3.1
Electrical
Electrical |
- |
pdf_text |
| 904.3.1 |
904.3.1
Electrical
Electrical |
- |
pdf_text |
| 904.3.2-907.2.11.4 |
904.3.2-907.2.11.4
Fire
Fire |
- |
pdf_text |
| 904.3.2-907.2.11.4 |
904.3.2-907.2.11.4
Fire
Fire |
- |
pdf_text |
| 905.2.1 |
905.2.1 for a duration of 30 minutes.
Exceptions |
- |
pdf_text |
| 905.2.1.1 |
905.2.1.1 Riser sizing: The riser size shall be based on hydraulic calculatio
minimum flow of 500 gallons per minute (gpm) (1892 L/min.).
Exceptions: |
- |
pdf_text |
| 905.2.1.1 |
905.2.1.1 Riser sizing: The riser size shall be based on hydraulic calculations f
minimum flow of 500 gallons per minute (gpm) (1892 L/min.).
Exceptions: |
- |
pdf_text |
| 905.2.1.1 |
905.2.1.1 and 905.2.1.2. The pipe size shall be based on the capacity of the aut
water supply system or, where an automatic water supply is neither required n
provided to maintain the residual pressure of 65 psi (448 kPa), the pipe size sh
based on a pressure of 150 psi (1,034 kPa) available at the fire department con
Exception: The residual pressure of 65 psi (448 kPa) is not required in
equipped throughout with an automatic sprinkler system installed in accorda
either Section 903.3.1.1 or 903.3.1.2 and also where the highest floor level is
than 150 feet (45720 mm) above the lowest level of fire department vehicle ac |
- |
pdf_text |
| 905.2.1.2 |
905.2.1.2 System pipe sizing: The system piping, including the horizontal or c
feeder lines shall be sized for a minimum flow of 500 gpm (1,892 L/min.). Wh
than one standpipe riser is required or provided, all common system piping sha
sized for a minimum flow of 500 gpm (1892 L/min.) for the first riser plus 250
(945 L/min.) for each additional riser, and the total shall not be required to exc |
- |
pdf_text |
| 905.2.1.2 |
905.2.1.2 System pipe sizing: The system piping, including the horizontal
common feeder lines shall be sized for a minimum flow of 500 gpm (1,892
Where more than one standpipe riser is required or provided, all common s
piping shall be sized for a minimum flow of 500 gpm (1892 L/min.) for the
riser plus 250 gpm (945 L/min.) for each additional riser, and the total shall
required to exceed 1,250 gpm (4731 L/min.).
Exceptions |
- |
pdf_text |
| 905.2.2 |
905.2.2 Water supply: A water supply for fire department equipment shall be a
to the building site. The water supply shall be capable of a minimum flow as re
by Section 905.2.1.2 for a duration of 30 minutes. |
- |
pdf_text |
| 905.2.2 |
905.2.2 Water supply: A water supply for fire department equipment s
available to the building site. The water supply shall be capable of a mi
flow as required by Section 905.2.1.2 for a duration of 30 minutes. |
- |
pdf_text |
| 905.2.2.1 |
905.2.2.1 Automatic water supply: An automatic water supply is required for
standpipe systems. The automatic water supply and supply piping shall be capa
delivering a flow of 500 gpm (1892 L/min.) at the residual pressure specified i |
- |
pdf_text |
| 905.2.2.1 |
905.2.2.1 Automatic water supply: An automatic water supply is required f
standpipe systems. The automatic water supply and supply piping shall be
of delivering a flow of 500 gpm (1892 L/min.) at the residual pressure spec |
- |
pdf_text |
| 907.1.2 |
907.1.2 Fire alarm shop drawings. Shop drawings for fire alarm systems shall
submitted for review and approval prior to system installation, and shall includ
not be limited to, all of the following where applicable to the system being inst |
- |
pdf_text |
| 907.11.5-907.2.11.6 |
907.11.5-907.2.11.6
Electrical/Fire
Electrical |
- |
pdf_text |
| 907.11.5-907.2.11.6 |
907.11.5-907.2.11.6
Electrical/Fire
Electrical |
- |
pdf_text |
| 907.2.11.7-907.3.2 |
907.2.11.7-907.3.2
Fire
Fire |
- |
pdf_text |
| 907.2.11.7-907.3.2 |
907.2.11.7-907.3.2
Fire
Fire |
- |
pdf_text |
| 907.2.9 |
907.2.9A, Group R-4. An automatic smoke detection system that activates the
notification system in accordance with Section 907.5 shall be installed in corr
waiting areas open to corridors, and habitable spaces other than sleeping u
kitchens.
Exceptions: |
- |
pdf_text |
| 907.2.9 |
907.2.9A, Group R-4. An automatic smoke detection system that acti
occupant notification system in accordance with Section 907.5 shall be in |
- |
pdf_text |
| 907.3.3 |
907.3.3
Elevator/Fire
Fire |
- |
pdf_text |
| 907.3.3 |
907.3.3
Elevator/Fire
Fire |
- |
pdf_text |
| 907.3.4 |
907.3.4
Electrical/Fire
Electrical |
- |
pdf_text |
| 907.3.4 |
907.3.4
Electrical/Fire
Electrical |
- |
pdf_text |
| 907.4-907.5.2.2.4 |
907.4-907.5.2.2.4
Fire
Fire |
- |
pdf_text |
| 907.4-907.5.2.2.4 |
907.4-907.5.2.2.4
Fire
Fire |
- |
pdf_text |
| 907.5.2.2.5 |
907.5.2.2.5
Electrical/Fire
Electrical |
- |
pdf_text |
| 907.5.2.2.5 |
907.5.2.2.5
Electrical/Fire
Electrical |
- |
pdf_text |
| 907.5.2.3-907.6 |
907.5.2.3-907.6
Fire
Fire |
- |
pdf_text |
| 907.5.2.3-907.6 |
907.5.2.3-907.6
Fire
Fire |
- |
pdf_text |
| 907.6.1-907.6.2 |
907.6.1-907.6.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 907.6.1-907.6.2 |
907.6.1-907.6.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 907.6.3-909.10.5 |
907.6.3-909.10.5
Fire
Fire |
- |
pdf_text |
| 907.6.3-909.10.5 |
907.6.3-909.10.5
Fire
Fire |
- |
pdf_text |
| 908.5-908.6 |
908.5-908.6
Plumbing
Plumbing |
- |
pdf_text |
| 908.5-908.6 |
908.5-908.6
Plumbing
Plumbing |
- |
pdf_text |
| 908.7 |
908.7
Plumbing/Fire
Plumbing |
- |
pdf_text |
| 908.7 |
908.7
Plumbing/Fire
Plumbing |
- |
pdf_text |
| 908.8 |
908.8
Building/Plumbing
Plumbing |
- |
pdf_text |
| 908.8 |
908.8
Building/Plumbing
Plumbing |
- |
pdf_text |
| 909-910 |
909-910
Building/Fire
Fire |
- |
pdf_text |
| 909-910 |
909-910
Building/Fire
Fire |
- |
pdf_text |
| 909.11 |
909.11
Electrical/Fire
Electrical |
- |
pdf_text |
| 909.11 |
909.11
Electrical/Fire
Electrical |
- |
pdf_text |
| 909.11.1 |
909.11.1
Fire/Building
Building |
- |
pdf_text |
| 909.11.1 |
909.11.1
Fire/Building
Building |
- |
pdf_text |
| 909.11.2 |
909.11.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 909.11.2 |
909.11.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 909.12-909.12.1 |
909.12-909.12.1
Fire
Fire |
- |
pdf_text |
| 909.12-909.12.1 |
909.12-909.12.1
Fire
Fire |
- |
pdf_text |
| 909.12.2 |
909.12.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 909.12.2 |
909.12.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 909.12.3-909.19 |
909.12.3-909.19
Fire
Fire |
- |
pdf_text |
| 909.12.3-909.19 |
909.12.3-909.19
Fire
Fire |
- |
pdf_text |
| 909.20-909.20.6.1 |
909.20-909.20.6.1
Building/Fire
Building |
- |
pdf_text |
| 909.20-909.20.7.1 |
909.20-909.20.7.1
Building/Fire
Building |
- |
pdf_text |
| 909.20.6.2 |
909.20.6.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 909.20.6.3-910.4.5 |
909.20.6.3-910.4.5
Fire
Fire |
- |
pdf_text |
| 909.20.7.2 |
909.20.7.2
Electrical/Fire
Electrical |
- |
pdf_text |
| 909.20.7.3-910.4.5 |
909.20.7.3-910.4.5
Fire
Fire |
- |
pdf_text |
| 910.4.6 |
910.4.6
Electrical/Fire
Electrical |
- |
pdf_text |
| 910.4.6 |
910.4.6
Electrical/Fire
Electrical |
- |
pdf_text |
| 910.4.7-911.1.1 |
910.4.7-911.1.1
Fire
Fire |
- |
pdf_text |
| 910.4.7-911.1.1 |
910.4.7-911.1.1
Fire
Fire |
- |
pdf_text |
| 911-914 |
911-914
Building/Fire
Building |
- |
pdf_text |
| 911-914 |
911-914
Building/Fire
Building |
- |
pdf_text |
| 911.1.2 |
911.1.2
Building/Fire
Building |
- |
pdf_text |
| 911.1.2 |
911.1.2
Building/Fire
Building |
- |
pdf_text |
| 911.1.3-913.2 |
911.1.3-913.2
Fire
Fire |
- |
pdf_text |
| 911.1.3-913.2 |
911.1.3-913.2
Fire
Fire |
- |
pdf_text |
| 912.2 |
912.2 as follows: |
- |
pdf_text |
| 912.6.1 |
912.6.1 and "fire code official" shall be deleted and "fire protection subcode offici
be inserted.
lxxv. Section 912.4.2, Clear space around connections, shall be renumbered as 91
"except as otherwise required or approved by the fire code official" shall be delete
lxxvi. Section 912.4.3, Physical protection, shall be renumbered as 912.6.3.
lxxvii. Section 912.5, Signs, shall be renumbered 912.7.
lxxviii. Section 912.6, Backflow protection, shall be renumbered as 912.8. Also,
"International Plumbing Code" shall be deleted and "the plumbing subcode (N.J.A |
- |
pdf_text |
| 913.2.1 |
913.2.1
Building/Fire
Building |
- |
pdf_text |
| 913.2.1 |
913.2.1
Building/Fire
Building |
- |
pdf_text |
| 913.3-915.4 |
913.3-915.4
Fire
Fire |
- |
pdf_text |
| 913.3-915.4 |
913.3-915.4
Fire
Fire |
- |
pdf_text |
| 915 |
915
Fire
Fire |
- |
pdf_text |
| 915 |
915
Fire
Fire |
- |
pdf_text |
| 915.4.1 |
915.4.1
Electrical/Fire
Electrical |
- |
pdf_text |
| 915.4.1 |
915.4.1
Electrical/Fire
Electrical |
- |
pdf_text |
| 915.4.2-916.3 |
915.4.2-916.3
Fire
Fire |
- |
pdf_text |
| 915.4.2-916.3 |
915.4.2-916.3
Fire
Fire |
- |
pdf_text |
| 916 |
916
Electrical/Plumbing
Electrical if
electric/Plumbing if
oil fired |
- |
pdf_text |
| 916 |
916
Electrical/Plumbing
Electrical if
electric/Plumbing if
oil fired |
- |
pdf_text |
| 916.4-916.5 |
916.4-916.5
Electrical/Fire
Electrical |
- |
pdf_text |
| 916.4-916.5 |
916.4-916.5
Electrical/Fire
Electrical |
- |
pdf_text |
| 916.6-918 |
916.6-918
Fire
Fire
Ch. |
- |
pdf_text |
| 916.6-918 |
916.6-918
Fire
Fire
C
h.
Means of Egress |
- |
pdf_text |
| 917 |
917
Fire
Fire |
- |
pdf_text |
| 917 |
917
Fire
Fire |
- |
pdf_text |
| 918 |
918
Building/Fire
Building |
- |
pdf_text |
| 918 |
918
Building/Fire
Building |
- |
pdf_text |
| 919 |
919
Plumbing
Plumbing |
- |
pdf_text |
| 919 |
919
Plumbing
Plumbing |
- |
pdf_text |
| 920-923 |
920-923
Building/Fire
Building |
- |
pdf_text |
| 920-923 |
920-923
Building/Fire
Building |
- |
pdf_text |
| 924 |
924
Fire
Fire |
- |
pdf_text |
| 924 |
924
Fire
Fire |
- |
pdf_text |
| 925 |
925
Building/Fire
Building |
- |
pdf_text |
| 925 |
925
Building/Fire
Building |
- |
pdf_text |
| 926 |
926
See Chapter 7 of
See Chapter 7 of
the International
the International
Fuel Gas Code
Fuel Gas Code |
- |
pdf_text |
| 926 |
926
See Chapter 7 of
See Chapter 7 of
the International
the International
Fuel Gas Code
Fuel Gas Code |
- |
pdf_text |
| 927 |
927
Electrical
Electrical |
- |
pdf_text |
| 927 |
927
Electrical
Electrical |
- |
pdf_text |
| 928 |
928
Building/Plumbing
Plumbing |
- |
pdf_text |
| 928 |
928
Building/Plumbing
Plumbing |
- |
pdf_text |
| 929 |
929
Building/Fire
Building |
- |
pdf_text |
| 929 |
929
Building/Fire
Building |
- |
pdf_text |
| 930 |
930
Electrical/Fire
Electrical
Ch. |
- |
pdf_text |
| 930 |
930
Electrical/Fire
Electrical |
- |
pdf_text |
| 931 |
931
Electrical/Plumbing
Electrical
Ch. |
- |
pdf_text |
| 99 |
99,360
*
(36,000
(36,000
per floor)
per floor)
a. Exception--Open parking structures in accordance with Section 406.5
*Requirements as set forth in this code
xi. In Section 903.3.1.1.1, Exempt locations, "fire code official" shall be deleted a
protection subcode official" shall be inserted in number 2.
xii. In Section 903.3.5, Water supplies, "International Plumbing Code" shall be de
and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. Additionally, i
sentence, "fire code official" shall be deleted and "fire protection subcode official"
inserted.
xiii. In Section 903.3.6, Hose threads, "fire code official" shall be deleted and "fir
protection subcode official" shall be inserted.
xiv. Section 903.3.8, Limited area sprinkler systems, Section 903.3.8.1, Number o
sprinklers, Section 903.3.8.2, Occupancy hazard classification, Section 903.3.8.3,
arrangement, Section 903.3.8.4, Supervision, and Section 903.3.8.5, Calculations,
deleted and the following shall be inserted in its place: "903.3.8 Limited area sprin
systems. Limited area sprinkler systems serving fewer than 20 sprinklers on any si
connection are permitted to be connected to the domestic service where a wet auto
standpipe is not available. Limited area sprinkler systems connected to domestic w
supplies shall comply with each of the following requirements: |
- |
pdf_text |
| 99 |
99,360
*
*
(36,000
per floor)
Group S-2<a>
IIB
IIIB
VB
Story
Max. Area
Max. Area
Max. Area |
- |
pdf_text |
| 99 |
99,360
*
(36,000
(36,000
per floor)
per floor)
Group F-2
IIB
IIIB
VB
Story
Max. Area
Max. Area
Max. Area |
- |
pdf_text |
| Note 1 |
Note 1: Where the device is wireless and plugged into an existing receptacle, plan re
inspection shall be plumbing; otherwise, electrical. |
- |
pdf_text |
| Note 1 |
Note 1: Penetrations in existing buildings shall be the responsibility of the subcode
review and inspection responsibility for the item doing the penetration. |
- |
pdf_text |
| Note 1 |
Note 1: Penetrations in existing buildings shall be the responsibility of the subcode with plan review and
inspection responsibility for the item doing the penetration. |
- |
pdf_text |
| Note 1 |
Note 1: Joint with Elevator Subcode Official for N.J.A.C. 5:23-12
devices not installed in Group R-3, R-4 or R-5 or in structures of Group R-2
in which the elevator devices are wholly within dwelling units and are not
accessible to the general public. |
- |
pdf_text |
| Note 1 |
Note 1: Where the device is wireless and plugged into an
existing receptacle, plan review and inspection shall be plumbing;
otherwise, electrical. |
- |
pdf_text |
| Note 1 |
Note 1: Joint with Elevator Subcode Official for N.J.A.C. 5:23-12 devices not in
Group R-3, R-4 or R-5 or in structures of Group R-2 in which the elevator devices ar
within dwelling units and are not accessible to the general public. |
- |
pdf_text |
| Note 2 |
Note 2: For multi-purpose systems installed in accordance with NFPA 13D, the assig
enforcement responsibilities shall be the same as the assignment of enf
responsibilities for systems installed in accordance with P2904. |
- |
pdf_text |
| Note 2 |
Note 2: The following sections are enforced by the Electrical inspector when devices
by N.J.A.C. 5:23-12 are installed in any building excluding installations in Group R-
R-5 or in structures of Group R-2 where the elevator devices are located wholly w
dwelling units and are not accessible to the general public. |
- |
pdf_text |
| Note 2 |
Note 2: For multi-purpose systems installed in accordance with NFPA 13D, the assignment of enforcement
responsibilities shall be the same as the assignment of enforcement responsibilities for systems installed in
accordance with P2904. |
- |
pdf_text |
| Note 2 |
Note 2: The following sections are enforced by the Electrical inspector
when devices covered by N.J.A.C. 5:23-12 are installed in any building
excluding installations in Group R-3, R-4 or R-5 or in structures of Group R-2
where the elevator devices are located wholly within the dwelling units and
are not accessible to the general public. |
- |
pdf_text |
| Note 3 |
Note 3: Inspection responsibility for this section shall be the
*4electrical inspector when devices are installed in buildings of Group R-3, R-4
or R-5 or in buildings of Group R-2 where the elevator devices are located
wholly within dwelling units and not accessible to the general public. |
- |
pdf_text |
| Note 3 |
Note 3: Inspection responsibility for this section shall be the electrical inspector whe
are installed in buildings of Group R-3, R-4 or R-5 or in buildings of Group R-2
elevator devices are located wholly within dwelling units and not accessible to th
public. |
- |
pdf_text |
| Section 1012.6.3 |
Section 1012.6.3, Exception 1; and Section 1012.6.4, Exception.
xiv. In Section 1010.1.1, Size of Doors, Exception 9 shall be deleted.
xv. In Section 1010.1.4, Floor elevation, in Exception 3, "7 3/4 inches (197 mm)"
deleted and "8 1/4 inches (210 mm)" shall be inserted. Additionally, Exception 5 s
deleted.
xvi. In Section 1010.1.6, Thresholds, in the Exception #1, "7 3/4 inches (197 mm)
be deleted and "8 1/4 inches (210 mm)" shall be inserted. Additionally, Exception
be deleted.
xvii. In Section 1010.2.2, Hardware, "locks" shall be deleted.
xviii. Section 1010.2.4, Locks and latches, shall be amended as follows: In Item 3
following "Group A," insert "other than nightclubs". In the same item, "and in" sha
inserted before the word "Groups" and "and in places of religious worship" shall b
deleted. In the same section, Item 11 shall be inserted as follows: "11. Key operati
be permitted from a dwelling unit provided that the key cannot be removed from t
when the door is locked from the side from which egress is made."
xix. In Section 1010.2.9, Panic and fire exit hardware, in exception 1, "other than
nightclubs" shall be inserted after "Group A occupancies." |
- |
pdf_text |
| Section 1012.6.4 |
Section 1012.6.4.
xiii. At Section 1010.1.1, Size of Doors, Exception 7 shall be deleted.
xiv. In Section 1010.1.4, Floor elevation, in Exception 3, "7 3/4 inches (197 mm)"
deleted and "8 1/4 inches (210 mm)" shall be inserted. Additionally, Exception 5 s
deleted.
xv. In Section 1010.1.6, Thresholds, in the Exception #1, "7 3/4 inches (197 mm)"
deleted and "8 1/4 inches (210 mm)" shall be inserted. Additionally, Exception #2
deleted.
xvi. In Section 1010.2.2, Hardware, "locks" shall be deleted.
xvii. Section 1010.2.4, Locks and latches, shall be amended as follows: In Item 3,
following "Group A," insert "other than nightclubs". In the same item, "and in" sha
inserted before the word "Groups" and "and in places of religious worship" shall b
deleted. In the same section, Item 11 shall be inserted as follows: "11. Key operati
be permitted from a dwelling unit provided that the key cannot be removed from t
when the door is locked from the side from which egress is made."
xviii. At Section 1010.2.8, Panic and fire exit hardware, in Exception 1, "other tha
nightclubs" shall be inserted after "Group A occupancies." |
- |
pdf_text |
| Section 105 |
Section 105."
iii. In Section 301.11, Plumbing connections, delete "International Plumbing Cod
insert "plumbing subcode (N.J.A.C. 5:23-3.15)" in its place.
iv. Section 301.14, Repair, is deleted.
v. Add new section 301.19, Safety devices and controls, as follows:
"Oil burners, other than oil stoves with integral tanks, shall be provided with
manually stopping the flow of oil to the burner. Such device or devices shall be pl
readily accessible location a minimum of 10 feet from the burner. For electrical
equipment, an identified switch in the burner supply circuit shall be provide
entrance to the room or area where the appliance is located or, for equipment l
basements, the switch is required to be located at the top of stairs leading to the b
An identifiable valve in the oil supply line, operable from a location a minimum
from the burner shall be used for other than electrically driven or controlled equip
vi. Section 307.1, Fuel-burning appliances, shall be amended to insert "drywell, s
pump, floor drain, drainage system below floor" after "fixture."
vii. Section 307.2.1, Condensate disposal, is amended to add the following after th
"disposal" on line 3: "in accordance with the plumbing subcode." In addition, the s
sentence shall be deleted. In addition, Section 307.2.1.1, Condensate discharge, is
in its entirety.
viii. Section 307.2.2, Drain pipe materials and sizes, is deleted.
ix. Section 309, Temperature control, is deleted. |
- |
pdf_text |
| Section 105 |
Section 105."
iii. Section 301.14, Repair, is deleted.
iv. Add new section 301.19, Safety devices and controls, as follows:
"Oil burners, other than oil stoves with integral tanks, shall be provided with
manually stopping the flow of oil to the burner. Such device or devices shall be pl
readily accessible location a minimum of 10 feet from the burner. For electrical
equipment, an identified switch in the burner supply circuit shall be provide
entrance to the room or area where the appliance is located or, for equipment l
basements, the switch is required to be located at the top of stairs leading to the b
An identifiable valve in the oil supply line, operable from a location a minimum
from the burner shall be used for other than electrically driven or controlled equip
v. Section 307.1, Fuel-burning appliances, shall be amended to insert "drywell, su
pump, floor drain, drainage system below floor" after "fixture."
vi. Section 307.2.1, Condensate disposal, is amended to add the following after th
"disposal" on line 3: "in accordance with the plumbing subcode." In addition, the s
sentence shall be deleted. In addition, Section 307.2.1.1, Condensate discharge, is
in its entirety.
vii. Section 307.2.2, Drain pipe materials and sizes, is deleted.
viii. Section 309, Temperature control, is deleted. |
- |
pdf_text |
| Section 12.10.2 |
Section 12.10.2.
b. Each water closet below the top floor shall be individually back ven |
- |
pdf_text |
| Section 1705.12.3 |
Section 1705.12.3, Wind-resisting components shall be deleted in their entirety.
xxviii. At Section 1705.13.1.1, Seismic force-resisting systems, "B, C," shall be d
reference to seismic design categories. Additionally, Exception 1 shall be deleted.
xxix. At Section 1705.13.1.2, Structural steel elements, "B, C," shall be deleted i
reference to seismic design categories. In addition, Exception 1 shall be deleted.
xxx. In Section 1705.13.2, Structural wood, in the first sentence, "C," shall be del
reference to seismic design categories.
xxxi. At Section 1705.13.3, Cold-formed steel light-frame construction, in the fir
sentence, "C," shall be deleted in reference to seismic design categories.
xxxii. In Section 1705.13.4, Designated seismic systems, in the first sentence, "C,
be deleted in reference to seismic design categories.
xxxiii. In Section 1705.13.6, Plumbing, Mechanical and Electrical Components, i |
- |
pdf_text |
| Section 1705.5.2 |
Section 1705.5.2, Metal-plate-connected wood trusses spanning 60 feet or greater,
deleted. Additionally, Section 1705.5.3, Mass timber construction shall be renumb |
- |
pdf_text |
| Section 302.4 |
Section 302.4 through |
- |
pdf_text |
| Section 312 |
Section 312 of the International Fire Code. For the purpose of applying this provis
"subject to vehicle impact" shall mean located within three feet of any garage door
opening, driveway or designated parking area and not separated by a building wall
the space where a vehicle may be operated.
Exception: If verification of the installation of an excess flow valve is provided b
utility, vehicle impact barriers shall not be required."
x. In Section G2413.7.1, Operation below -5⁰F (21⁰C), insert the following at the
beginning of the section: "The operating pressure for undiluted LP-gas systems sh
exceed 20 psig (140 kPa gauge)."
xi. In Section G2425.15.2, Flue passageways, in the first sentence, "free of obstru
and combustible deposits" shall be deleted and "inspected in accordance with the c
verification program as provided for in N.J.A.C. 5:23-2.20(d)" shall be inserted.
xii. In Section G2427.5.5, Inspection of chimneys, "examined to ascertain that it i
and free of obstructions" shall be deleted and "inspected in accordance with the ch
verification program as provided for in N.J.A.C. 5:23-2.20(d)" shall be inserted.
xiii. In Section G2448.1.1, Installation requirements, "this code" shall be deleted a
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted.
xiv. In Section G2448.2, Water heaters utilized for space heating, "this code" shal
deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| Section 680.25 |
Section 680.25(A)(1) of the NEC/2011, shall be inserted:
"Exception: An existing feeder between an existing remote panelboard an
equipment shall be permitted to run in flexible metal conduit or an approv
assembly that includes an equipment grounding conductor within its outer she
equipment grounding conductor shall comply with 250.24(A)(5)." |
- |
pdf_text |
| Section 905.2.1 |
Section 905.2.1 for a duration of 30 minutes.
Exceptions |
- |
pdf_text |
| Section 907.5.2.2.5 |
Section 907.5.2.2.5, Emergency power. Emergency voice/alarm commu
systems shall be provided with emergency power in accordance with Section 2
system shall be capable of powering the required load for a duration of not les
hours, as required in NFPA 72.
xliii. In Section 907.6.6.2, MIY Monitoring, "fire code official" shall be delete
"fire protection subcode official" shall be inserted.
xlix. In Section 907.6.6.2, MIY Monitoring, "fire code official" shall be delete
"fire protection subcode official" shall be inserted.
l. In Section 909.5.2, Testing of leakage area, "fire code official" shall be delet
"fire protection subcode official" shall be inserted.
li. In Section 909.7, Airflow design method, "fire code official" shall be delete
"fire protection subcode official" shall be inserted. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
In (b)10ii9, substituted "804.5" for "804.6" five times; in (b)10ii12, substituted "Location" for
"Accessible route"; in (b)10vi, deleted the period following "1104.4.1.2", and in 1104.4.2.2, subst
"a" for "the" and inserted ", of less than 3,000 square feet,"; added (b)10vii and (b)10xix, and rec
existing paragraphs to accommodate these insertions.
Amended by R.2018 d.060, effective January 16, 2018.
See: 49 N.J.R. 1276(a), 50 N.J.R. 310(a).
In the introductory paragraph of (b), substituted "shall be" for "are"; and in (b)3xvii, in the third
undesignated paragraph, substituted "five" for "5", in the fourth undesignated paragraph, deleted
quote preceding the semicolon, and added the fifth undesignated paragraph.
Amended by R.2018 d.153, effective August 20, 2018.
See: 49 N.J.R. 2332(a), 50 N.J.R. 1888(a).
Added new (b)10ii13 and (b)10l, recodified former (b)10ii13 through (b)10ii20 as (b)10ii14 thro
(b)10ii21; rewrote (b)10vi and (b)10xxxviii; and recodified former (b)10l through (b)10lii as (b)1
through (b)10liii.
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Amended by R.2021 d.004, effective January 4, 2021.
See: 52 N.J.R. 385(a), 53 N.J.R. 47(a).
Rewrote (b).
Amended by R.2022 d.022, effective February 7, 2022.
See: 53 N.J.R. 1133(a), 54 N.J.R. 263(a).
Rewrote (b)2; added (b)4x; recodified former (b)4x a |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
(1) An adaptable entrance, with the plans for the adaptation to provide an
accessible entrance.
(A) For the purposes of fulfilling this requirement, the use of a platfor
a limited use limited application elevator shall be acceptable;
(2) An adaptable toilet and bathing facility on the first floor;
(3) An adaptable kitchen on the first floor;
(4) An accessible interior route of travel.
(A) An interior accessible route of travel shall not be required between
and
(5) An adaptable room that can be used as a bedroom, with a door or the c
the installation of a door, on the first floor."
xli. In Section 1108.7, General exceptions, "and Type B units" shall be deleted.
Additionally, in the last line "1108.7.5" shall be deleted and "1108.7.3" inserted in
place.
xlii. Section 1108.7.1, Structures without elevator service, 1108.7.1.1, One story
Type B units required, and 1108.7.1.2, Additional stories with Type B units, shall
deleted in their entirety.
xliii. Section 1108.7.2, Multistory units, shall be renumbered as Section 1108.7.1.
sentence of this section shall be deleted and replaced with the following: A multist
dwelling unit or sleeping unit that is not provided with elevator service is required
accessible as follows: The primary entrance to the unit shall comply with the requi
for a Type A unit and, where provided within the unit, a living area, kitchen, and t
bathing facility that comply with Type A dwelling un |
- |
pdf_text |
| full-text |
Pa
APPENDIX 3-A
____________________
____________________
____________________
____________________
Supporting Statement (reason for code change):
____________________
____________________
____________________
____________________
____________________
History
HISTORY:
New Rule, R.2004 d.261, effective July 6, 2004.
See: 36 N.J.R. 1267(a), 36 N.J.R. 3275(a).
Administrative correction, effective October 3, 2023.
See: 55 N.J.R. 2257(a).
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.2 Matters covered; exceptions
See: 29 N.J.R. 3387(a), 29 N.J.R. 4285(a).
Substantially amended (b)1.
Amended by R.1999 d.424, effective December 6, 1999.
See: 31 N.J.R. 2428(a), 31 N.J.R. 4001(c).
In (a)1, substituted a reference to rehabilitation for a reference to alteration, and changed guideli
reference.
Administrative correction.
See: 33 N.J.R. 3735(a).
Amended by R.2003 d.157, effective April 21, 2003.
See: 34 N.J.R. 4247(a), 35 N.J.R. 1663(b).
In (d)5, added ii.
Administrative correction.
See: 35 N.J.R. 5062(a).
Amended by R.2003 d.425, effective November 3, 2003.
See: 35 N.J.R. 2424(a), 35 N.J.R. 5062(b).
Rewrote (d).
Amended by R.2004 d.131, effective April 5, 2004.
See: 35 N.J.R. 5336(a), 36 N.J.R. 1755(a).
In(d)3, inserted the first sentence.
Amended by R.2004 d.423, effective November 15, 2004.
See: 36 N.J.R. 3004(a), 36 N.J.R. 5090(a).
In (d)5, rewrote ii.
Amended by R.2006 d.157, effective May 1, 2006. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
(1) An adaptable entrance, with the plans for the adaptation to provide an
accessible entrance.
(A) For the purposes of fulfilling this requirement, the use of a platfor
a limited use limited application elevator shall be acceptable;
(2) An adaptable toilet and bathing facility on the first floor;
(3) An adaptable kitchen on the first floor;
(4) An accessible interior route of travel.
(A) An interior accessible route of travel shall not be required between
and
(5) An adaptable room that can be used as a bedroom, with a door or the c
the installation of a door, on the first floor."
xli. Section 1108.7.1, Structures without elevator service, 1108.7.1.1, One story w
B units required, and 1108.7.1.2, Additional stories with Type B units, shall be del
their entirety.
xlii. Section 1108.7.2, Multistory units, the first sentence of this section shall be d
and replaced with the following: A multistory dwelling unit or sleeping unit that is
provided with elevator service is required to be accessible as follows: The primary
to the unit shall comply with the requirements for a Type A unit and, where provid
within the unit, a living area, kitchen, and toilet and bathing facility that comply w
A dwelling unit shall be provided on that floor. In the third line, "Type B dwelling
shall be deleted and "Type A unit" inserted in its place. Additionally, in the fourth
following the word "toilet," "and bathing" shall be inserted.
xl |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
addition, under construction Type VA for Group A-3 NS, "2" shall be deleted
shall be inserted and for Group A-3 S, "3" shall be deleted and "2" shall be ins
(5) Under construction Type IB for Group A-4 NS, "11" shall be deleted and "
be inserted and for Group A-4 S, "12" shall be deleted and "6" shall be inserted
construction Type IVB for A-4 S, "12" shall be deleted and "6" shall be inserte
addition, under construction Type VA for Group A-4 NS, "2" shall be deleted
shall be inserted and for Group A-4 S, "3" shall be deleted and "2" shall be ins
(6) The allowable number of stories for Group A-5 NS and S, construction Ty
IV HT, VA, and VB shall be deleted.
(7) Under construction Type IB for Group B NS, "11" shall be deleted and "7"
inserted and for Group B S, "12" shall be deleted and "8" shall be inserted. Un
construction Type IIIA for Group B NS, "5" shall be deleted and "4" shall be i
and for Group B S, "6" shall be deleted and "5" shall be inserted. In addition, u
construction Type IVB for B S, "12" shall be deleted and "8" shall be inserted.
(8) Under construction Type IB for Group F-1 NS, "11" shall be deleted and "
be inserted and for Group F-1 S, ""12" shall be deleted and "7" shall be inserte
(9) Under construction Type IB for Group F-2 NS, "11" shall be deleted and "
be inserted and for Group F-2 S, "12" shall be deleted and "8" shall be inserted
(10) Under Occupancy Classifications H-1, H-2, H-3, H-4, and H-5, the row t
|
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
ii. In Section 901.5, Acceptance test, in the second sentence, "building official" sh
deleted and "fire protection subcode official" shall be inserted.
iii. In Section 903.1.1, Alternative protection, "fire code official" shall be deleted
protection subcode official" shall be inserted.
iv. New Section 903.1.2, Residential systems, shall be inserted as follows:
"903.1.2 Residential systems. Unless specifically allowed by this code, residen
sprinkler systems installed in accordance with NFPA 13D or NFPA 13R shall
recognized for the purpose of exceptions or reductions permitted by other requ
of this code."
v. Section 903.2.1.2., Group A-2, shall be amended to add a new section 903.2.1.2
follows: "903.2.1.2.1 In Group A-2 Nightclubs, the automatic sprinkler system sha
to the performance sound system and to the house lights in such a way that activati
the automatic sprinkler system mutes the performance sound system and restores t
intensity of illumination to that required by Section 1008.2.1."
vi. Section 903.2.2, Ambulatory Care Facilities, "Evacuation is impractical for" sh
inserted at the beginning of the sentence in item 1, and "are incapable of self-prese
shall be deleted. "Evacuation is impractical for" shall be inserted at the beginning
sentence in item 2, and "that are incapable of self-preservation" shall be deleted.
vii. In Section 903.2.6, Group I, Exception # 2, insert "For other than buildings of
construction T |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.144, effective March 20, 1995 (operative July 1, 1995).
See: 26 N.J.R. 2698(a), 26 N.J.R. 3524(a), 27 N.J.R. 1180(a).
Amended by R.1995 d.477, effective September 5, 1995.
See: 27 N.J.R. 1717(a), 27 N.J.R. 3328(a).
Added (b)2v.
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.2000 d.492, effective December 18, 2000.
See: 32 N.J.R. 3219(a), 32 N.J.R. 4437(b).
Rewrote (b)25.
Amended by R.2001 d.127, effective April 16, 2001.
See: 33 N.J.R. 392(a), 33 N.J.R. 1195(a).
In (a)9, added new ix and recodified former ix through xiii as new x through xiv.
Amended by R.2001 d.368, effective October 15, 2001.
See: 33 N.J.R. 1990(a), 33 N.J.R. 3673(b).
In (b)9, inserted a new ix and recodified former ix through xiv as x through xv.
Amended by R.2001 d.369, effective October 15, 2001.
See: 33 N.J.R. 2365(a), 33 N.J.R. 3674(a).
In (b), substituted "seven" for "7 1/3 (2335 mm)" in 2vi, rewrote 10, added a new 17, and recodi
former 17 through 26 as 18 through 27. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
Rewrote (c)3xvi; and in (c)4viii, paragraph R406.1.1, substituted "R406.4.2" for "R406.4.1".
Amended by R.2025 d.111, effective October 6, 2025.
See: 56 N.J.R. 2263(a), 57 N.J.R. 2305(a).
Rewrote (c)3xxiv.
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
(6) Under Occupancy Classification I-1 Condition 1, I-3, the row that begins
shall be deleted.
(7) Under Occupancy Classification I-1 Condition 2, I-2, the row that begins
shall be deleted.
(8) Under the Occupancy Classification I-4, in the second column, the referen
footnote d shall be deleted from the NS.
(9) Under Occupancy Classification R, the row that begins with NS shall be d
iii. Table 504.4, ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLA
shall be amended as follows:
(1) c, d, e, f, and h shall be deleted.
(2) Under construction Type VA for Group A-1 NS, "2" shall be deleted and "
be inserted and for Group A-1 S, "3" shall be deleted and "2" shall be inserted.
(3) Under construction Type IB for Group A-2 NS, "11" shall be deleted and "
be inserted and for Group A-2 S, "12" shall be deleted and "4" shall be inserted
construction Types IIA and IIB for Group A-2 NS, "3" and "2" shall be deleted
and "1" shall be inserted, respectively, and for Group A-2 S, "4" and "3" shall
deleted and "3" and "2" shall be inserted, respectively. Under construction Typ
and IIIB for Group A-2 NS, "3" and "2" shall be deleted and "2" and "1" shall
inserted, respectively, and for Group A-2 S, "4" and "3" shall be deleted and "3
"2" shall be inserted, respectively. Under construction Type IVC for Group A-
shall be deleted and "2" shall be inserted. Under construction Types IVB and I
Group A-2 S, "12" and "6" shall be deleted and "4" and " |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.8 Products violating the Code
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1997 d.508, effective December 1, 1997.
See: 29 N.J.R. 3762(a), 29 N.J.R. 5062(a).
In (d)2i, added reference to CSA/NRTL standards; in (d)3i, added the exception for transition gl
inserted (d)3vi.
Recodified from N.J.A.C. 5:23-3.8A by R.2003 d.384, effective October 6, 2003.
See: 35 N.J.R. 2422(a), 35 N.J.R. 4712(a).
Former N.J.A.C. 5:23-3.8, Department approval of nonconforming materials, repealed.
Amended by R.2007 d.310, effective October 1, 2007.
See: 39 N.J.R. 135(a), 39 N.J.R. 4113(b).
In (d)2i, updated the National Electrical Code references, deleted "/Nationally Recognized Testi
Laboratory" following "Canadian Standards Association" and "/NRTL" following "CSA", and ins
last sentence.
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In (d)1i, substituted "803.1" for "803.2"; and in (d)1ii, substituted "804" for "805.2".
Amended by R.2023 d.030, effective March 6, 2023.
See: 54 N.J.R. 1661(a), 55 N.J.R. 349(a).
In (d)1i and (d)1ii, substituted "Section" for "section"; in (d)1i, inserted "or other equivalent stan
and (d)1ii, inserted ", or other equivalent standards".
Amended by R.2026 d.087, effective August 17, 2026.
See: 57 N.J.R. 2333(a), 58 N.J.R. 1882(a). |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
xii. The definition of "detoxification facilities" shall be amended as follows: the p
"who are incapable of self-preservation or are harmful to themselves or others" sha
deleted, and "where evacuation is impractical" shall be inserted.
xiii. In the definition of "dwelling unit," "living as a single housekeeping unit" sha
inserted after "persons."
xiv. The definition of "evacuation, impractical" shall be inserted as follows:
"EVACUATION, IMPRACTICAL. The movement of all occupants, residents an
an exit in more than 13 minutes."
xv. The definition of "evacuation, slow" shall be inserted as follows:
"EVACUATION, SLOW. The movement of all occupants, residents and staff t
in more than 3 minutes, but not more than 13 minutes."
xvi. The definition of "existing building" shall be deleted.
xvii. The definition of "existing structure" shall be deleted.
xviii. The definition of "foster care facilities" shall be deleted.
xix. The definition of "historic building" shall be deleted.
xx. The definition of "hospitals and psychiatric hospitals" shall be amended as foll
"who are incapable of self-preservation" shall be deleted, and "where evacuation is
impractical" shall be inserted.
xxi. The definition of "incapable of self-preservation" shall be deleted. This deleti
include its cross-reference definition of the term "self-preservation, incapable of."
xxii. The definition of "jurisdiction" shall be deleted.
xxiii. The de |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
In (b)21ii, inserted "insert" twice, substituted "8.6" for "8.6.1.6.5" and deleted "shall be inserted"
preceding "after" twice.
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote the section.
Amended by R.2012 d.179, effective November 5, 2012.
See: 44 N.J.R. 1679(a), 44 N.J.R. 2557(a).
Added new (b)9xlvi, (b)10xxx and (b)10xxxi; recodified former (b)9xlvi through (b)9liii as (b)9
through (b)9liv; and recodified former (b)10xxx through (b)10xxxviii as (b)10xxxii through (b)10
Amended by R.2013 d.081, effective June 3, 2013.
See: 44 N.J.R. 1303(a), 45 N.J.R. 1393(a).
In (b)17i, substituted "1" for "I".
Administrative correction.
See: 46 N.J.R. 74(b).
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Amended by R.2017 d.107, effective June 5, 2017.
See: 48 N.J.R. 1851(a), 49 N.J.R. 1381(b).
Added (b)8lxxvi through (b)8lxxx.
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11A Public school facility plan review and inspections; Uniform Construction Code enhancements in p
school facilities
Text conformed to P.L. 1990, c.23, qualified agencies may perform plan review of public school
structures.
Amended by R.1991 d.309, effective June 17, 1991.
See: 23 N.J.R. 1084(a), 23 N.J.R. 1922(a).
Rule conformed to P.L. 1990 c. 23; text at (c) revised to specify type of project covered; BOCA
updated; reference to N.J.A.C. 6:22 added.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1997 d.417, effective October 6, 1997.
See: 29 N.J.R. 3387(a), 29 N.J.R. 4285(a).
Deleted (a); recodified former (b) through (e) as (a) through (d); in (b), Inserted "Prior to the rele
projects,"; in (b)1 and 2, inserted "public" preceding "school buildings"; in (c)7, deleted option of
inspecting agency requiring subsequent correction of any errors in the plans, inserted second sent
in third sentence amended notice provisions.
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
In (d), substituted "alarm" for "detection", changed BOCA reference and substituted a reference
for a reference to (e)5ii in 5, and changed BOCA in 6.
Amended by R.2000 d.166, effective April 17, 2000.
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
Rewrote the section.
Amended by R.2001 d.127, effective April 16, 2001.
See: 33 N.J.R |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
Amended by R.2011 d.269, effective November 7, 2011.
See: 43 N.J.R. 904(a), 43 N.J.R. 3008(a).
Added new (c)3vii; deleted former (c)3xxii; recodified former (c)3vii through (c)3xxi as (c)3viii
(c)3xxii; added new (c)19xii; and recodified former (c)19xii through (c)19xv as (c)19xiii through
(c)19xvi.
Special amendment, R.2014 d.161, effective October 1, 2014 (to expire May 12, 2015).
See: 46 N.J.R. 2186(a).
Rewrote (c)3.
Adopted concurrent amendment, R.2015 d.077, effective April 15, 2015.
See: 46 N.J.R. 2186(a), 47 N.J.R. 989(b).
Provisions of R.2014 d.161 adopted without change.
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Administrative correction.
See: 47 N.J.R. 2753(a).
Amended by R.2019 d.083, effective August 5, 2019.
See: 51 N.J.R. 3(a), 51 N.J.R. 1269(a).
In (c)3xl, inserted "new" and "and 'relocated' shall be inserted in lieu thereof".
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Amended by R.2021 d.004, effective January 4, 2021. |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.8 Products violating the Code
In (d)3v, inserted commas following "of July 1, 1991" and "or later"; and inserted ", or as requir
pursuant to N.J.S.A. 52:27D-141.21, whichever is more restrictive".
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Amended by R.2001 d.368, effective October 15, 2001.
See: 33 N.J.R. 1990(a), 33 N.J.R. 3673(b).
In (b)9, inserted a new ix and recodified former ix through xiv as x through xv.
Amended by R.2001 d.369, effective October 15, 2001.
See: 33 N.J.R. 2365(a), 33 N.J.R. 3674(a).
In (b), substituted "seven" for "7 1/3 (2335 mm)" in 2vi, rewrote 10, added a new 17, and recodi
former 17 through 26 as 18 through 27.
Amended by R.2002 d.215, effective July 1, 2002.
See: 34 N.J.R. 1078(a), 34 N.J.R. 2312(a).
In (b)22, inserted new ii and recodified existing ii through xvii as iii through xviii.
Administrative correction.
See: 34 N.J.R. 3771(b).
Amended by R.2003 d.187, effective May 5, 2003.
See: 34 N.J.R. 4248(a), 35 N.J.R. 1939(c).
Rewrote the section.
Administrative correction.
See: 35 N.J.R. 2864(b).
Amended by R.2003 d.351, effective September 2, 2003.
See: 35 N.J.R. 1177(a), 35 N.J.R. 4051(a).
In (b)9, added xi; recodified existing xi to xiii as xii to xiv.
Amended by R.2003 d.420, effective November 3, 2003.
See: 34 N.J.R. 4248(a), 35 N.J.R. 5073(a).
Rewrote (b). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Amended by R.1986 d.380, effective September 22, 1986.
See: 18 N.J.R. 1235(a), 18 N.J.R. 1931(a), 18 N.J.R. 2063(a).
Substantially amended.
Amended by R.1987 d.14, effective January 5, 1987.
See: 18 N.J.R. 2083(a), 19 N.J.R. 63(a).
(f)4 added; old (f)4-6 renumbered (f)5-7.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
(a)1 through 4: model subcode revisions.
Amended by R.1990 d.226, effective May 7, 1990.
See: 21 N.J.R. 3696(a), 22 N.J.R. 1356(a).
Provisions for enforcement of radon subcode added at (g).
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1991 d.325, effective July 1, 1991.
See: 23 N.J.R. 805(a), 23 N.J.R. 2046(a).
Other elevator devices covered; enforcement responsibilities clarified.
Amended by R.1992 d.147, effective April 6, 1992.
See: 24 N.J.R. 170(a), 24 N.J.R. 1397(a).
Elevators wholly within R-2 residences exempt.
Amended by R.1992 d.183, effective April 20, 1992.
See: 24 N.J.R. 167(a), 24 N.J.R. 1475(b). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
In (a), (b), and (c), inserted "CABO Model Energy Code" following "ENERGY SUBCODE" an
ASHRAE Standard 90.1 tables throughout.
Amended by R.2004 d.312, effective August 16, 2004.
See: 35 N.J.R. 4947(a), 36 N.J.R. 3894(d).
Rewrote the section.
Administrative correction.
See: 37 N.J.R. 269(a).
Amended by R.2005 d.364, effective November 7, 2005.
See: 37 N.J.R. 2112(a), 37 N.J.R. 4216(a).
Rewrote the section.
Amended by R.2005 d.446, effective December 19, 2005.
See: 37 N.J.R. 2747(a), 37 N.J.R. 4907(a).
Rewrote (a)3.
Administrative correction.
See: 38 N.J.R. 926(a).
Administrative correction.
See: 38 N.J.R. 1827(b).
In (a)3, Note 1 of the table, inserted "in" following "not installed".
Amended by R.2007 d.310, effective October 1, 2007.
See: 39 N.J.R. 135(a), 39 N.J.R. 4113(b).
Added (a)9.
Amended by R.2008 d.112, effective May 5, 2008.
See: 39 N.J.R. 4366(a), 40 N.J.R. 2229(a). |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.12
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
August 17, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.12 Amended rules
Whenever the Commissioner shall make any modifications to the rules, notice of same shall be p
in the New Jersey Register.
History
HISTORY:
Amended by R.1995 d.544, effective October 16, 1995.
See: 27 New Jersey Register 2827(a), 27 New Jersey Register 3933(a).
Amended by R.2000 d.413, effective October 16, 2000.
See: 32 New Jersey Register 2278(a), 32 New Jersey Register 3783(a).
Rewrote the section.
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
iii. In Section 903.1.1, Alternative protection, "fire code official" shall be deleted
protection subcode official" shall be inserted.
iv. New Section 903.1.2, Residential systems, shall be inserted as follows:
"903.1.2 Residential systems. Unless specifically allowed by this code, reside
sprinkler systems installed in accordance with NFPA 13D or NFPA 13R shall
recognized for the purpose of exceptions or reductions permitted by other requ
of this code."
v. Section 903.2.1.2., Group A-2, shall be amended to add a new section 903.2.1.2
follows: "903.2.1.2.1 In Group A-2 Nightclubs, the automatic sprinkler system sha
to the performance sound system and to the house lights in such a way that activati
the automatic sprinkler system mutes the performance sound system and restores t
intensity of illumination to that required by Section 1008.2.1."
vi. At Section 903.2.6, Group I, Exception 2, insert "For other than buildings of
construction types IIB or VB," at the beginning of the sentence.
vii. In Section 903.2.7.2, Group M upholstered furniture or mattresses, the text sh
deleted, and the following language from Section 903.2.7, item 4, of the IBC/2018
inserted: An automatic sprinkler system shall be provided throughout buildings co
a Group M Occupancy utilized for the display and sale of upholstered furniture or
mattresses exceeding 5,000 square feet
viii. In Section 903.2.11.1, Stories without openings, ", of all buildings |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3, Appx. 3-A
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
June 15, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
APPENDIX 3-A
APPENDIX
NEW JERSEY DEPARTMENT OF COMMUNITY AFFAIRS
DIVISION OF CODES AND STANDARDS
CODE CHANGE PROPOSAL
REHABILITATION SUBCODE (N.J.A.C. 5:23-6)
Proposals must be presented with language proposed for deletion in brackets[].
Proposals must be presented with language proposed for addition underlined:
Mail code change proposals to:
Fax code change proposals to:
Code Development Unit
Code Development Unit
Department of Community Affairs
(609) 633-6729
Division of Codes and Standards
PO Box 802
Trenton, New Jersey 08625
Direct questions to the Code Development or Code Assistance Units at (609) 984-7609.
Section (citation) proposed for change: ____________________
Sections (companion changes) that might also need to be changed:
____________________
NAME: ____________________
ORGANIZATION (if any): ____________________
ADDRESS: ____________________
____________________
TELEPHONE: ____________________ FAX: ____________________ E-mail: ____________________
Proposed Code Change:
____________________ |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
In (c)3ii1, substituted "19-1" for "94-8"; in (c)3ii2, substituted "19-1"for "03-4"; in (c)3ii8, subst
"2'6" " for "2'8" "; deleted (c)3xxiii and recodified (c)3xxiv through (c)3xxv as (c)3xxiii through (
added (c)3xxv; in (c)3xliv3, deleted 3.9 and recodified 3.10 and 3.11 as 3.9 and 3.10; in (c)4v, su
"R404.2.5" for "404.2.5"; in (c)4vii, substituted "R404.4" for "404.4"; and in (c)12iv, substituted
"M1307.5" for "1307.5".
Amended by R.2022 d.022, effective February 7, 2022.
See: 53 N.J.R. 1133(a), 54 N.J.R. 263(a).
Recodified the former second occurrence of (c)3xix as (c)3xxxix.
Administrative change, effective July 6, 2022.
See: 54 N.J.R. 1551(a).
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Administrative correction, effective October 25, 2023.
See: 55 N.J.R. 2322(b).
Administrative correction, effective December 6, 2023.
See: 56 N.J.R. 35(b).
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a).
Petition for Rulemaking.
See: 57 N.J.R. 1448(b), 1619(c).
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
Rewrote (c)3xvi; and in (c)4viii, paragraph R406.1.1, substituted "R406.4.2" for "R406.4.1". |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.20 Mechanical subcode
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1991 d.429, effective August 19, 1991.
See: 23 N.J.R. 1487(a), 23 N.J.R. 2501(a).
In (a), added 3. Added new (c).
Amended by R.1992 d.183, effective April 20, 1992.
See: 24 N.J.R. 167(a), 24 N.J.R. 1475(b).
Text added at (b)7 and (c)1, deleting parts of article 16 of the mechanical subcode.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.120, effective March 6, 1995 (operative July 1, 1995).
See: 26 N.J.R. 4874(b), 27 N.J.R. 894(b).
Amended by R.1999 d.259, effective August 16, 1999.
See: 31 N.J.R. 825(a), 31 N.J.R. 2330(a).
Added (c).
Amended by R.2001 d.196, effective June 18, 2001.
See: 33 N.J.R. 6(a), 33 N.J.R. 2090(a).
Rewrote (a) and (b).
Administrative correction.
See: 33 N.J.R. 3310(a).
Amended by R.2002 d.15, effective January 22, 2002.
See: 33 N.J.R. 2933(b), 33 N.J.R. 3883(a), 34 N.J.R. 521(a).
In (c), added the last sentence in the introductory paragraph, and rewrote 1. |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.12
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
June 15, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.12 Amended rules
Whenever the Commissioner shall make any modifications to the rules, notice of same shall be p
in the New Jersey Register.
History
HISTORY:
Amended by R.1995 d.544, effective October 16, 1995.
See: 27 New Jersey Register 2827(a), 27 New Jersey Register 3933(a).
Amended by R.2000 d.413, effective October 16, 2000.
See: 32 New Jersey Register 2278(a), 32 New Jersey Register 3783(a).
Rewrote the section.
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.18 Energy subcode
Amended by R.1988 d.50, effective February 1, 1988.
See: 19 N.J.R. 1862(b), 20 N.J.R. 268(a).
Added (b)6; renumbered (b)6.-7. as (b)7.-8.
Amended by R.1988 d.417, effective September 6, 1988.
See: 20 N.J.R. 699(b), 20 N.J.R. 2274(a).
Substantially amended.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1991 d.326, effective July 1, 1991.
See: 23 N.J.R. 804(a), 23 N.J.R. 2044(a).
Section E-502.1 deleted.
Amended by R.1991 d.429, effective August 19, 1991.
See: 23 N.J.R. 1487(a), 23 N.J.R. 2501(a).
In (b)5, deleted old and added new i.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.143, effective March 20, 1995 (operative July 1, 1995).
See: 26 N.J.R. 4872(a), 27 N.J.R. 1179(b).
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.2001 d.244, effective July 16, 2001 (operative January 16, 2002). |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.16 Electrical subcode
(b)5; in (b)4.ii, substituted "(2)" for "(1)", in (b)5iii(1), substituted "4" for "2"; in (b)5iii(2), substi
"V" for "VI" and "551.20" for "551.10"; and inserted (b)6.
Amended by R.2007 d.310, effective October 1, 2007.
See: 39 N.J.R. 135(a), 39 N.J.R. 4113(b).
Added (b)7.
Amended by R.2007, d.384, effective December 17, 2007.
See: 39 N.J.R. 2684(a), 39 N.J.R. 5211(a).
Added new (b)4ii; recodified former (b)4ii as (b)4iii; and in (b)4iii, substituted "(2)" for "(1)".
Amended by R.2008 d.213, effective August 4, 2008.
See: 39 N.J.R. 2411(a), 40 N.J.R. 4523(b).
Rewrote (b)5iv.
Amended by R.2009 d.100, effective April 6, 2009.
See: 40 N.J.R. 5900(a), 41 N.J.R. 1397(a).
In the introductory paragraphs of (a)1 and (a)2 and in (a)2i, substituted "2008" for "2005"; in (a)
substituted "#09-1" for "#06-2", rewrote (b)3i; added (b)4iv and (b)4v; added new(b)5ii; recodifie
(b)5ii through (b)5iv as (b)5iii through (b)5v; deleted (b)5iii(1)(A) and former (b)5iv(1); recodifie
former (b)5iv(2) as new (b)5iv(1); in (b)6, substituted "H" for "G"; and rewrote (b)7.
Amended by R.2010 d.291, effective December 20, 2010.
See: 42 N.J.R. 1943(a), 42 N.J.R. 3053(a).
Rewrote (b)6; and added (b)8.
Amended by R.2012 d.083, effective May 7, 2012.
See: 44 N.J.R. 10(a), 44 N.J.R. 1336(a).
In the introductory paragraph of (a)1 and (a)2, and in (a)2i, substituted "2011" for "2008"; in (a)
substituted "I |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
Amended by R.2025 d.111, effective October 6, 2025.
See: 56 N.J.R. 2263(a), 57 N.J.R. 2305(a).
Rewrote (c)3xxiv.
Amended by R.2026 d.086, effective August 17, 2026.
See: 57 N.J.R. 2354(a), 58 N.J.R. 1898(a).
Rewrote the section.
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.8 Products violating the Code
End of Document |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.17 Fire protection subcode
In the introductory paragraph of (a)1i, of (a)1iii and of (a)iv, substituted "2009" for "2006"; in (a
substituted "Fire and Smoke Protection Features" for "Fire Resistance-Rated Construction"; in (a)
substituted "2613" for "2607"; and in the introductory paragraph of (a)1ii, substituted "2008" for
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
In the introductory paragraph of (a)1, substituted "fuel gas, and one- and two-family dwelling su
to the extent delineated in N.J.A.C. 5:23-3.4, as the fire protection subcode for New Jersey" for "a
gas"; and added (a)1v.
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a).
Amended by R.2026 d.086, effective August 17, 2026.
See: 57 N.J.R. 2354(a), 58 N.J.R. 1898(a).
Rewrote the section.
Annotations
Notes
Chapter Notes
Case Notes |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
Rewrote the section.
Administrative correction, effective October 25, 2023.
See: 55 N.J.R. 2322(b).
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
Rewrote (b)11ii and (b)11iii.
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
(4) Under construction Type IB for Group A-3 NS, "11" shall be deleted and "
be inserted and for Group A-3 S, "12" shall be deleted and "6" shall be inserted
construction Type IVB for A-3 S, "12" shall be deleted and "6" shall be inserte
addition, under construction Type VA for Group A-3 NS, "2" shall be deleted
shall be inserted and for Group A-3 S, "3" shall be deleted and "2" shall be ins
(5) Under construction Type IB for Group A-4 NS, "11" shall be deleted and "
be inserted and for Group A-4 S, "12" shall be deleted and "6" shall be inserted
construction Type IVB for A-4 S, "12" shall be deleted and "6" shall be inserte
addition, under construction Type VA for Group A-4 NS, "2" shall be deleted
shall be inserted and for Group A-4 S, "3" shall be deleted and "2" shall be ins
(6) The allowable number of stories for Group A5 NS and S, construction Typ
IV-A, IV-B, IV-C, HT, V-A, and V-B shall be deleted.
(7) Under construction Type IB for Group B NS, "11" shall be deleted and "7"
inserted and for Group B S, "12" shall be deleted and "8" shall be inserted. Un
construction Type IIIA for Group B NS, "5" shall be deleted and "4" shall be i
and for Group B S, "6" shall be deleted and "5" shall be inserted. In addition, u
construction Type IVB for B S, "12" shall be deleted and "8" shall be inserted.
(8) Under construction Type IB for Group F-1 NS, "11" shall be deleted and "
be inserted and for Group F-1 S, "12" shall be deleted and "7 |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.16 Electrical subcode
Rewrote the section.
Amended by R.2003 d.240, effective June 16, 2003.
See: 34 N.J.R. 3045(a), 35 N.J.R. 2637(c).
Added (c).
Amended by R.2006 d.158, effective May 1, 2006.
See: 37 N.J.R. 4105(a), 38 N.J.R. 1827(a).
In (a)1, (a)2 and (a)2.i, substituted "2005" for "2002"; also in (a)2.i, substituted "#06-2" for "#03
(a)3, substituted "C2-2002" for "C2-l997"; deleted (b)1 and recodified (b)2 through (b)6 as (b)1 t
(b)5; in (b)4.ii, substituted "(2)" for "(1)", in (b)5iii(1), substituted "4" for "2"; in (b)5iii(2), substi
"V" for "VI" and "551.20" for "551.10"; and inserted (b)6.
Amended by R.2007 d.310, effective October 1, 2007.
See: 39 N.J.R. 135(a), 39 N.J.R. 4113(b).
Added (b)7.
Amended by R.2007, d.384, effective December 17, 2007.
See: 39 N.J.R. 2684(a), 39 N.J.R. 5211(a).
Added new (b)4ii; recodified former (b)4ii as (b)4iii; and in (b)4iii, substituted "(2)" for "(1)".
Amended by R.2008 d.213, effective August 4, 2008.
See: 39 N.J.R. 2411(a), 40 N.J.R. 4523(b).
Rewrote (b)5iv.
Amended by R.2009 d.100, effective April 6, 2009.
See: 40 N.J.R. 5900(a), 41 N.J.R. 1397(a).
In the introductory paragraphs of (a)1 and (a)2 and in (a)2i, substituted "2008" for "2005"; in (a)
substituted "#09-1" for "#06-2", rewrote (b)3i; added (b)4iv and (b)4v; added new(b)5ii; recodifie |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.15 Plumbing subcode
section, at Item 2, "24" shall be inserted in the blank space provided. In addition, i
third line of Item 2, "6" shall be inserted in the blank space provided.
vi. Section 2.19.1, Availability of Public Water and Sewer, is amended to delete t
and the words "feet of any property line of the premises, or other."
vii. Section 2.19.2, Private Systems, is amended to delete the words "the Health
Department or other agency having jurisdiction" and substitute in lieu thereof "The
Jersey Department of Environmental Protection."
viii. New Section 2.19.3, Common Systems, shall be inserted as follows:
a. Common water services shall be permitted to serve attached single-family d
in groups of three or more where the common water service is located within p
subject to an association easement or on common property and there is a home
association or other owner entity responsible for maintenance and upkeep.
b. Common building sewers shall be permitted to serve attached single-family
dwellings in groups of three or more where the common sewer is located withi
property subject to an association easement or on common property and there i
homeowners' association or other owner entity responsible for maintenance an
upkeep.
ix. Section 2.24, Toilet Facilities for Construction Workers, shall be deleted in its
x. Section 2.26.1, General, shall be amended as follows:
(1) Subsection b. shall be deleted.
(2) In subsection d, "Phase II firefight |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.17 Fire protection subcode
Zoning ordinance's definition of family violated Constitution. Cherry Hill Tp. v. Oxford House,
N.J.Super. 25, 621 A.2d 952 (A.D.1993).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.21 One- and two-family dwelling subcode
xxxii. Section R321, Elevators and platform lifts, shall be deleted.
xxxiii. In Section R322.1, General, "repair" shall be deleted and "restoration" shal
inserted.
xxxiv. Section R322.1.1, Alternative provisions, shall be deleted in its entirety.
xxxv. In Section R322.1.6, Protection of mechanical, plumbing and electrical syst
second sentence shall be deleted.
xxxvi. In Section R322.1.7, Protection of water supply and sanitary sewage syste
first and second sentences, "and replacement" shall be deleted. Also, in the second
sentence, "the plumbing provisions of this code and Chapter 3 of the International
Sewage Disposal Code" shall be deleted and "the plumbing subcode (N.J.A.C. 5:2
shall be inserted.
xxxvii. In Section R322.1.9, Manufactured homes, in the first sentence, "new and
replacement" shall be deleted and "relocated" shall be inserted in lieu thereof.
xxxviii. In Section R322.2.3, Foundation design and construction, "For buildings
supported by piles, the design and methods of construction shall meet the applicab
criteria of ASCE 24." shall be inserted after the first sentence.
xxxix. In Section R322.3, Coastal high-hazard areas (including V Zones and Coas
Zones, where designated), "Sections R322.3.1 through R322.3.10" shall be deleted
"ASCE 24" shall be inserted in its place. Additionally, the subsections that follow
of R322.3, Sections R322.3.1 through R322.3.10, shall be deleted.
xl. S |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
the irrigation cycle of the automatic lawn sprinkler system when rainfall of more than one
inch has occurred.
History
HISTORY:
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1983 d.12, eff. February 7, 1983, operative February 22, 1983.
See: 14 N.J.R. 1326(a), 15 N.J.R. 141(c).
Added (a) 3 and (c).
Amended by R.1984 d.314, eff. August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b).
Section substantially amended.
Amended by R.1986 d.12, effective February 3, 1986.
See: 17 N.J.R. 2714(a), 18 N.J.R. 267(a).
(a)1i had a change of address; (a)3 and (c) added.
Amended by R.1987 d.81, effective February 2, 1987.
See: 18 N.J.R. 2237(b), 19 N.J.R. 289(d).
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1989 d.66, effective February 6, 1989.
See: 20 N.J.R. 2846(a), 21 N.J.R. 288(a). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Amended by R.2007 d.51, effective February 5, 2007.
See: 38 N.J.R. 375(a), 39 N.J.R. 371(a).
Added new (b)2viii; recodified former (b)2viii through (b)2x as (b)2ix through (b)2xi; added ne
recodified former (b)3iii through (b)3viii as (b)3iv through (b)3ix; added new (b)9i; recodified fo
(b)9i through (b)9xi as (b)9ii through (b)9xii; added new (b)9xiii; recodified former (b)9xii throu
(b)9xv as (b)9xiv through (b)9xvii; added new (b)10xxii and (b)10xxiii; and recodified former (b)
as (b)10xxiv.
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
Rewrote the section.
Administrative correction.
See: 39 N.J.R. 1249(a).
Amended by R.2007, d.384, effective December 17, 2007.
See: 39 N.J.R. 2684(a), 39 N.J.R. 5211(a).
Added new (b)3i and (b)3ii; and recodified former (b)3i through (b)3vii as (b)3iii through (b)3ix
Amended by R.2008 d.39, effective March 3, 2008.
See: 39 N.J.R. 2175(a), 40 N.J.R. 1084(a).
Added new (b)24iii; and recodified former (b)24iii as (b)24iv.
Administrative correction.
See: 40 N.J.R. 1829(a).
Amended by R.2008 d.184, effective July 7, 2008.
See: 39 N.J.R. 2176(a), 40 N.J.R. 3990(a).
Deleted former (b)9vii; and recodified former (b)9viii through (b)9xlii as (b)9vii through (b)9xli
Amended by R.2009 d.48, effective February 2, 2009. |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
family dwellings that are outside the scope of the one- and two-family dwelling su
"Group homes with five or fewer occupants in accordance with Section 308.2.4,"
"Rooming houses with five or fewer occupants," and "Single residential occupanci
accessory to a dwelling unit, having no more than five roomers or lodgers. (Single
occupancies, accessory to a dwelling unit, having more than five roomers or lodge
be classified as Group R-2 or I-1, as appropriate.)" shall be inserted.
xiii. Section 310.4.1, Care facilities within a dwelling, and Section 310.4.2, Lodgi
houses, shall be deleted.
xiv. In Section 310.5, Residential Group R-4, in the fifth line following "environ
comma shall be inserted and "and" shall be deleted. In the fifth line, following the
"care," the following shall be inserted: "and are capable of slow evacuation". Addi
in the list, the word "treatment" shall be inserted following "drug" in the first item;
"Assisted living facilities" and "Congregate care facilities" shall be deleted; and th
"Boarding houses" shall be inserted.
xv. New Section 310.6, Residential Group R-5, shall be inserted as follows: "Resi
Group R-5 occupancies shall include all detached one- and two-family dwellings n
than three stories in height with a separate means of egress and multiple single-fa
townhouses not more than three stories in height with a separate means of egress d
and constructed in accordance with the International Residential Code. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
xix. In Section 1010.3.4, Security grilles, "In Groups B, F, M, and S" shall be dele
"horizontal" shall be capitalized.
xx. At Section 1011.5.2, Riser height and tread depth, Exception 3, change the ma
riser height from "7 3/4 inches (197 mm)" to "8 1/4 inches (210 mm),", change the
minimum tread depth from "10 inches (254 mm)" to "9 inches (229 mm)," and cha
minimum winder tread depth at the walk line from "10 inches (254 mm)" to "9 inc
mm)." Additionally, at Exception 3, "not required by Chapter 11 to be Accessible
A dwelling or sleeping units" shall be deleted. In the same section, Exception 4 sh
deleted.
xxi. In Section 1013.5, Internally illuminated exit signs, "Chapter 27" shall be del
"the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
xxii. At Section 1014.2, Height, insert new Exception 4 as follows: "4. For occupa
Group R-3, and within individual dwelling units in occupancies of Group R-2, han
shall have a minimum height of 30 inches and a maximum height of 38 inches me
vertically from the nosing of the treads."
xxiii. At Section 1014.5, Continuity, Exception 4 shall be deleted.
xxiv. At Section 1015.3, Height, in Exception 1 "not more than three stories abov
in height" in the first line shall be deleted and "not more than three stories above g
height with separate means of egress" in the second line shall be deleted. Addition
Exception 4, "34 inches (864mm)" shall be deleted and "30 inches (762 mm)" |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
"NIGHTCLUB. All buildings and places of public assembly designed for use
halls, eating and/or drinking establishments, and similar occupancies, in w
established maximum permitted occupant load exceeds the number of seats pro
more than 30 percent or which affords less than 12 square feet net area per occu
purposes of determining the net area per occupant, only the actual public assembly
rooms shall be considered. For purposes of applying the requirements of this
nightclub shall include all rooms, lobbies and other spaces connected theret
common means of egress and entrance."
xxvi. The definition of nursing home shall be amended as follows: the phrase "inc
of self-preservation" shall be deleted, and "of impractical evacuation" shall be inse
xxvii. The definition of "owner" shall be deleted and the following shall be inserte
"OWNER. The owner or owners in fee of the property of a lesser estate therein, a
mortgagee or vendee in possession, an assignee of rents, receiver, executor, trustee
or any other person, firm or corporation, directly or indirectly in control of a buildi
structure or real property and shall include any subdivision thereof of the State."
xxviii. The definitions of "permit" and "person" shall be deleted.
xxix. A definition of "radioactive material" shall be inserted as follows:
"RADIOACTIVE MATERIAL. Any material or combination of mater
spontaneously emit ionizing radiation."
xxx. The definition of "Registe |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.9
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
August 17, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.9 Interpretations and opinions
(a) Whenever the Commissioner shall, in accordance with applicable provisions of the
Administrative Procedure Act, make any rule constituting an interpretation of any provisi
regulations, such shall be binding provided, however, that such interpretations shall be pro
in nature. Such interpretations shall not alter the ruling of a subcode official already rende
specific instance relating to a specific permit or structure. Requests for interpretations shal
the form, and submitted in accordance with the procedure, set forth in N.J.A.C. 5:2-2.
(b) In response to a written inquiry or request setting forth a specific factual situation, or
own initiative, the Construction Code Element may issue a formal technical opinion to cla
provisions of the adopted subcodes. Such formal technical opinion shall be signed by the
Director of the Element and shall be binding upon the Element and upon other code enfor
agencies and licensed officials. Formal technical opinions shall be prospective in nature, s
based upon adopted subcodes or upon authoritative test results or standards incorporated b
reference into an adopted subcode and shall not alter the ruling of a licensed official alrea
ren |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
In (b), inserted "that are" following "type 5B construction", "no more" preceding "than 4,800 sq
feet", and substituted "seven feet" for "7 1/3 feet (2,235 mm.)".
Amended by R.2003 d.187, effective May 5, 2003.
See: 34 N.J.R. 4248(a), 35 N.J.R. 1939(c).
Rewrote the section.
Amended by R.2003 d.420, effective November 3, 2003.
See: 34 N.J.R. 4248(a), 35 N.J.R. 5073(a).
Rewrote (c).
Amended by R.2005 d.403, effective November 21, 2005.
See: 37 N.J.R. 2753(a), 37 N.J.R. 4399(b).
Rewrote (c).
Amended by R.2006 d.28, effective January 17, 2006.
See: 37 N.J.R. 2750(a), 38 N.J.R. 485(b).
Rewrote (c)15.
Administrative correction.
See: 38 N.J.R. 926(a).
Amended by R.2006 d.75, effective February 21, 2006.
See: 37 N.J.R. 3110(a), 38 N.J.R. 1183(a).
Added (c)10; recodified former (c)10-15 as (c)11-16.
Administrative correction.
See: 38 N.J.R. 1827(b).
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.17 Fire protection subcode
(10) Chapter 17--Special Inspections and Tests;
(11) Sections 2111 through 2113 of Chapter 21--Masonry;
(12) Sections 2603 through 2613 of Chapter 26--Plastic;
(13) Chapter 27--Electrical;
(14) Chapter 30--Elevators and Conveying Systems;
(15) Section 3104 of Chapter 31--Special Construction;
(16) Section 3309, 3311 and 3312 of Chapter 33--Safeguards During Construc
ii. National Electrical Code of the National Fire Protection Association adopted as
amended at N.J.A.C. 5:23-3.16 as the electrical subcode:
(1) Section 110.3 of Chapter 1--General;
(2) Section 300.21 of Chapter 3--Wiring Methods and Materials;
(3) Article 450, Part III--Transformer Vaults of Chapter 4--Equipment for Gen
Use;
(4) Chapter 5--Special Occupancies;
(5) Article 695--Fire Pumps of Chapter 6--Special Equipment;
(6) Article 728--Fire-Resistive Cable Systems--Special Conditions;
(7) Article 760--Fire Alarm Systems of Chapter 7--Special Conditions.
iii. International Mechanical Code of the International Code Council, Inc. adopted
amended at N.J.A.C. 5:23-3.20 as the mechanical subcode:
(1) Chapter 3--General Regulations;
(2) Chapter 5--Exhaust Systems;
(3) Chapter 6--Duct Systems;
(4) Chapter 7--Combustion Air; |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.21 One- and two-family dwelling subcode
x. In the definition of "Dwelling Unit," "living as a single housekeeping unit" shal
inserted after "persons."
xi. The definition of "Existing Installations" shall be deleted.
xii. The definition of "Guestroom" shall be deleted.
xiii. The definition of "Historic Building" shall be deleted.
xiv. The definition of "Jurisdiction" shall be deleted.
xv. The definition of "Lodging House" shall be deleted.
xvi. The definition of "Manufactured Home" shall be deleted.
xvii. The definition of "Owner" shall be deleted and the following shall be inserte
"OWNER. The owner or owners in fee of the property of a lesser estate therein, a
mortgagee or vendee in possession, an assignee of rents, receiver, executor, trustee
or any other person, firm or corporation, directly or indirectly in control of a buildi
structure or real property and shall include any subdivision thereof of the State."
xviii. The definition of "Permit" shall be deleted.
xix. The definition of "Person" shall be deleted.
xx. In the definition of "Potable Water," "public health authority having jurisdicti
be deleted and "Public Health Drinking Water Standards or the regulations" shall b
inserted.
xxi. The definition of "Repair" shall be deleted.
xxii. The definitions of "Reroofing," "Roof Recover," "Roof Repair," and "Roof
Replacement" shall be deleted.
xxiii. The definition of "Structure" shall be deleted.
xxiv. The definition |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
"Convents," "Dormitories," "Fraternities and Sororities," "Monasteries," "Congreg
living facilities (transient) with 10 or fewer occupants," "Boarding Houses (transie
"Lodging houses with five or fewer guest rooms," and "Emergency services living
quarters" shall be deleted. The terms "Alcohol and drug treatment houses with 5 or
residents," "Detached one- and two-family dwellings greater than three stories in h
multiple single-family townhouses greater than three stories in height, attached tw
dwellings separated from adjacent units by firewalls, and other one- and two-famil
dwellings that are outside the scope of the one- and two-family dwelling subcode,"
homes with five or fewer occupants in accordance with Section 308.2.4," "Roomin
with five or fewer occupants," and "Single residential occupancies, accessory to a
unit, having no more than five roomers or lodgers. (Single occupancies, accessory
dwelling unit, having more than five roomers or lodgers shall be classified as Grou
I-1, as appropriate.)" shall be inserted.
xi. Section 310.4.1, Care facilities within a dwelling, and Section 310.4.2, Lodgin
shall be deleted.
xii. At Section 310.5, Residential Group R-4, in the list, the word "treatment" shal
inserted following "drug" in the first item; "Assisted living facilities" and "Congre
facilities" shall be deleted; and the term "Boarding houses" shall be inserted.
xiii. New Section 310.6, Residential Group R-5, shall be inserted a |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11 Enforcement activities reserved to the Department
and use of temporary structures in outdoor locations or work undertaken on locations othe
independent of a film studio set.
History
HISTORY:
Amended by R.1981 d.455, effective December 7, 1981.
See: 13 N.J.R. 561(b), 13 N.J.R. 886(b).
Correction: Codification error and (a)6 was missing.
See: 16 N.J.R. 1621(a).
Administrative Change: This section has been divided into 3.11 and 3.11A administratively.
See: 18 N.J.R. 1842(a).
Amended by R.1988 d.352, effective August 1, 1988.
See: 19 N.J.R. 1270(a), 20 N.J.R. 1873(b).
Added (f).
Amended by R.1990 d.313, effective June 18, 1990.
See: 22 N.J.R. 691(a), 22 N.J.R. 1915(b).
Industrialized/modular buildings requirements added to (a)7.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1991 d.325, effective July 1, 1991.
See: 23 N.J.R. 805(a), 23 N.J.R. 2046(a).
Enforcement of elevator, moving walk and escalator requirements for other than R-3 and R-4 re
Department. |
- |
pdf_text |
| full-text |
Pa
APPENDIX 3-A
____________________
____________________
____________________
____________________
Supporting Statement (reason for code change):
____________________
____________________
____________________
____________________
____________________
History
HISTORY:
New Rule, R.2004 d.261, effective July 6, 2004.
See: 36 N.J.R. 1267(a), 36 N.J.R. 3275(a).
Administrative correction, effective October 3, 2023.
See: 55 N.J.R. 2257(a).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.5 Posting structures
See: 21 N.J.R. 2783(a), 21 N.J.R. 3460(a).
Added reference to E Use Group (educational facilities) at (b).
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.2000 d.47, effective February 7, 2000.
See: 31 N.J.R. 2314(a), 32 N.J.R. 443(a).
Added (f).
Amended by R.2000 d.166, effective April 17, 2000.
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
Rewrote (d) and (e).
Amended by R.2009 d.48, effective February 2, 2009.
See: 40 N.J.R. 5319(a), 41 N.J.R. 733(b).
In (a), substituted "chapter 3" for "article 2".
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page 35 of 57
§ 5:23-3.4 Responsibilities
Cha
pter
Section/Title
Responsibility
Inspection
Plan Review
N1102.5
Building
Building
N1103.1
Electrical
Electrical
N1103.2
Plumbing
Plumbing
N1103.3
Building
Building
N1103.4
Plumbing
Plumbing
N1103.5.1.1 -
Plumbing
Plumbing
pump with
integrated switch
N1103.5.1.1 -
Electrical
Electrical
pump with
non-integrated
switch
N1103.5.1.2
Electrical
Electrical
N1103.5.2-N1103.5.3
Plumbing
Plumbing
N1103.6
Building
Building
N1103.7
Plumbing
Plumbing
N1103.8
As applicable
As applicable
N1103.9
Electrical
Electrical
N1103.10.1 -
Electrical
Electrical
Switch
N1103.10.1 -
Plumbing
Plumbing
Gas Heater, Pilot
N1103.10.2 -
Electrical
Electrical |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.13 Code change proposals
History
HISTORY:
Amended by R.2004 d.261, effective July 6, 2004.
See: 36 N.J.R. 1267(a), 36 N.J.R. 3275(a).
Rewrote the section.
Amended by R.2005 d.342, effective October 17, 2005.
See: 37 N.J.R. 2325(a), 37 N.J.R. 3974(a).
In (a)1, added "private party," and substituted "240" for "90"; in (a)2, added "party or", "compan
following "agency", and "if applicable,"; added (c).
Administrative correction, effective October 3, 2023.
See: 55 N.J.R. 2257(a).
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
"912.1A Connections: Fire department connections shall be arranged in su
manner that the attachment to any one sprinkler connection will serve all s
and the attachment to any one standpipe connection will serve all standpipe
the building.
Exception: Fire protection systems in high rise buildings designed with a
and a high zone may be provided with a connection for each zone."
lxii. Section 912.2, Location, "fire protection subcode official in coordination
local fire service or their designee" shall be inserted, and "fire code official" sh
deleted in the last sentence.
lxiii. Section 912.2.1, Visible location, "or as otherwise approved by the fire c
official" shall be deleted.
lxiv. Section 912.2.2, Existing buildings, shall be deleted in its entirety.
lxv. New Section 912.2A, Height, shall be inserted between Sections 912.2 an
as follows:
"912.2A, Height. Fire department connections shall not be less than 18 inc
mm) and more than 42 inches (1,067 mm) in elevation, measured from the gro
to the centerline of the inlets."
lxvi. Section 912.4, Access, in the last sentence of the section and the last sent
the exception, "fire code official" shall be deleted and "fire protection subcode
shall be inserted.
lxvii. Section 912.4.1, Locking fire department connection caps, "fire code off
shall be deleted and "fire protection subcode official" shall be inserted.
lxviii. Section 912.4.2, Clear space around connections, |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
Added new (c)17; and recodified existing (c)17 through (c)22 as (c)18 through (c)23.
Amended by R.2008 d.84, effective April 7, 2008.
See: 39 N.J.R. 5144(a), 40 N.J.R. 1827(a).
Deleted former (c)3xviii; recodified former (c)3xix through (c)3xxxi as (c)3xviii through (c)3xx
introductory paragraph of (c)4, inserted a comma following "Foundations"; and in (c)4iii, added t
second sentence.
Administrative correction.
See: 40 N.J.R. 1829(a).
Amended by R.2009 d.48, effective February 2, 2009.
See: 40 N.J.R. 5319(a), 41 N.J.R. 733(b).
In (c)3xxvii, inserted the final sentence; recodified the former second occurrence of (c)3xxiii as
(c)3xxviii; added new (c)4iii; recodified former (c)4iii and (c)4iv as (c)4iv and (c)4v; added new
recodified former (c)4v through (c)4vii as (c)4vii through (c)4ix; added (c)5iii; in (c)8i, inserted
"(N.J.A.C. 5:23-3.15)"; in (c)9iii, deleted "Figure R1003.11 and" following "In"; added new (c)1
recodified former (c)19ix through (c)19xiii as (c)19x through (c)19xiv; and rewrote (c)23iv.
Amended by R.2009 d.126, effective April 20, 2009.
See: 41 N.J.R. 16(a), 41 N.J.R. 1725(a).
Added new (c)4ii; and recodified former (c)4ii through (c)4ix as (c)4iii through (c)4x.
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote (a) and (c).
Amended by R.2011 d.269, effective November 7, 2011.
Se |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.16 Electrical subcode
In (a)1, inserted "and 19".
Amended by R.2026 d.086, effective August 17, 2026.
See: 57 N.J.R. 2354(a), 58 N.J.R. 1898(a).
Rewrote the section.
Annotations
Notes
Chapter Notes
Case Notes
Former N.J.A.C. 5:23-3.6 designated "National Electrical code of 1975" as controlling code;
limitations. Brown v. Jersey Central Power and Light Co., 163 N.J.Super. 179 394
(App.Div.1978) certification denied 79 N.J. 489 401 A.2d 244.
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
In (b)4iv, inserted "the" preceding "Construction" and substituted "2004" for "1998"; added (b)1
recodified former (b)10vi and (b)10vii as (b)10vii and (b)10viii; and in (b)10viii, substituted "200
"1999".
Amended by R.2009 d.48, effective February 2, 2009.
See: 40 N.J.R. 5319(a), 41 N.J.R. 733(b).
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote the section.
Amended by R.2013 d.081, effective June 3, 2013.
See: 44 N.J.R. 1303(a), 45 N.J.R. 1393(a).
Added new (b)3viii; recodified former (b)3viii through (b)3ix as (b)3ix through (b)3x; added ne
through (b)17iii; and recodified former (b)17ii through (b)17viii as (b)17iv through (b)17x.
Amended by R.2016 d.001, effective January 4, 2016.
See: 47 N.J.R. 2021(a), 48 N.J.R. 43(a).
Rewrote the section.
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In the introductory paragraph of (b)9v, deleted "(Siamese)" following "department".
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Amended by R.2022 d.120, effective September 19, 2022.
See: 54 N.J.R. 699(a), 54 N.J.R. 1793(a). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Generated Flood Hazard, Appendix N, Replicable Buildings, and Appendix O,
Performance-based application, shall be deleted in their entirety.
iv. At Appendix P, Sleeping Lofts, at the beginning of the Appendix, the sentence
provisions contained in this appendix are not mandatory unless specifically referen
the adopting ordinance," shall be deleted in its entirety.
History
HISTORY:
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1983 d.12, eff. February 7, 1983, operative February 22, 1983.
See: 14 N.J.R. 132(a), 15 N.J.R. 141(c).
Added (a)2 and (c).
Amended by R.1984 d.314, eff. August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b).
This section was substantially amended.
Amended by R.1985 d.154, effective April 1, 1985 (operative July 1, 1985.)
See: 17 N.J.R. 239(a), 17 N.J.R. 810(a).
(a)2 added; subsection (c) added.
Correction: N.J.A.C. 5:23-3.14(c)5 was incorrect in adoption.
See: 17 N.J.R. 1409(a).
Amended by R.1985 d.324, effective July 1, 1985.
See: 17 N.J.R. 861(c), 17 N.J.R. 1646(a).
(b)3i: amended text. |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.16 Electrical subcode
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
Amendments to (b)4i(2), ii(2).
Administrative Correction to (b)4i(2).
See: 22 N.J.R. 2503(b).
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.1998 d.362, effective July 20, 1998.
See: 30 N.J.R. 1122(a), 30 N.J.R. 2644(b).
In (a), inserted a new 3.
Amended by R.2000 d.48, effective February 7, 2000.
See: 31 N.J.R. 2317(a), 32 N.J.R. 445(a).
In (a), substituted references to 1999 for references to 1996 throughout, substituted a reference t
Batterymarch Park for a reference to Batterymarch Park in 1i, and inserted 2i; and in (b), inserted
inserted a new 3, recodified former 3 and 4 as 4 and 5, substituted a reference to line four for a ref
to line three and substituted a reference to line six for a reference to line five in the new 4i, and su
a reference to section 500-5(a)(4) for a reference to section 500-3(a)4 in the new 5i.
Amended by R.2003 d.187, effective May 5, 2003.
See: 34 N.J.R. 4248(a), 35 N.J.R. 1939(c). |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.15 Plumbing subcode
subcode, shall be installed such that the minimum earth cover is 42 inches." In the
section, at Item 2, "24" shall be inserted in the blank space provided. In addition, i
third line of Item 2, "6" shall be inserted in the blank space provided.
vi. Section 2.19.1, Availability of Public Water and Sewer, is amended to delete t
and the words "feet of any property line of the premises, or other."
vii. Section 2.19.2, Private Systems, is amended to delete the words "the Health
Department or other agency having jurisdiction" and substitute in lieu thereof "The
Jersey Department of Environmental Protection."
viii. New Section 2.19.3, Common Systems, shall be inserted as follows:
a. Common water services shall be permitted to serve attached single-family d
in groups of three or more where the common water service is located within p
subject to an association easement or on common property and there is a home
association or other owner entity responsible for maintenance and upkeep.
b. Common building sewers shall be permitted to serve attached single-family
dwellings in groups of three or more where the common sewer is located withi
property subject to an association easement or on common property and there i
homeowners' association or other owner entity responsible for maintenance an
upkeep.
ix. Section 2.24, Toilet Facilities for Construction Workers, shall be deleted in its
x. Section 2.26.1, General, shall be amended as follow |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
iv. In Section 3002.5, Emergency doors, "ASME A17.1/CSA B44" shall be delet
"ASME A17.1" shall be inserted.
v. In Section 3002.9, Plumbing and mechanical systems, in the exception, "witho
water separator" shall be inserted at the end of the sentence. In addition, the follow
sentence shall be inserted: "The discharge shall not be directly or indirectly connec
the sanitary drainage system."
vi. In Section 3003.1.3, Two or more elevators, the last sentence shall be deleted
following sentence shall be substituted "After all elevators have been returned to t
designated level, service to all floors shall be provided by not less than one elevato
shall remain operational from the standby power source."
vii. In Section 3003.2, Fire-fighters' emergency operation, "ASME A17.1/CSA B
be deleted and "ASME A17.1" shall be inserted.
viii. In Section 3003.3, Standardized fire service elevator keys, "International Fir
shall be deleted and "Elevator Safety Subcode (N.J.A.C. 5:23-12)" shall be inserte
ix. In Section 3005.6, Plumbing systems, add the following exception:
"Exception: Where machinery spaces and control spaces are located in the elev
floor drains, sumps and sump pumps shall be permitted in the pits provided the
indirectly connected to the plumbing system without an oil-water separator. Th
discharge shall not be directly or indirectly connected to the sanitary system."
x. At Section 3006.2, Elevator hoistway door protection required, |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.13 Code change proposals
History
HISTORY:
Amended by R.2004 d.261, effective July 6, 2004.
See: 36 N.J.R. 1267(a), 36 N.J.R. 3275(a).
Rewrote the section.
Amended by R.2005 d.342, effective October 17, 2005.
See: 37 N.J.R. 2325(a), 37 N.J.R. 3974(a).
In (a)1, added "private party," and substituted "240" for "90"; in (a)2, added "party or", "compan
following "agency", and "if applicable,"; added (c).
Administrative correction, effective October 3, 2023.
See: 55 N.J.R. 2257(a).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.5
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
June 15, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.5 Posting structures
(a) Posted use and occupancy: Every building and structure and part thereof designed for
business, factory and industrial, high hazard, mercantile, or storage use, (use groups B, F,
and S) as defined in chapter 3 of the building subcode shall be posted on all floors by the
with a suitably designed placard in a form designated by the building subcode official, wh
be securely fastened to the structure in a readily visible place, stating the use group and th
load and occupancy load.
(b) Posted occupancy load: Every building and structure and part thereof designed for use
place of public assembly or as an institutional building for harboring people for penal,
correctional, educational, medical or other care or treatment (use groups A, E and I) shall
posted with an approved placard designating the maximum occupancy load.
(c) Replacement of posted signs: All posting signs shall be furnished by the owner and sh
permanent design; they shall not be removed, or defaced and, if lost, removed or defaced,
immediately replaced.
(d) Posted hydraulic system data plate: In lieu of the nameplate of the referenced NFPA
standard(s), fire sprinkler system contractors are required to identify h |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
Rewrote (a) and (c).
Amended by R.2007, d.384, effective December 17, 2007.
See: 39 N.J.R. 2684(a), 39 N.J.R. 5211(a).
Added new (c)17; and recodified existing (c)17 through (c)22 as (c)18 through (c)23.
Amended by R.2008 d.84, effective April 7, 2008.
See: 39 N.J.R. 5144(a), 40 N.J.R. 1827(a).
Deleted former (c)3xviii; recodified former (c)3xix through (c)3xxxi as (c)3xviii through (c)3xx
introductory paragraph of (c)4, inserted a comma following "Foundations"; and in (c)4iii, added t
second sentence.
Administrative correction.
See: 40 N.J.R. 1829(a).
Amended by R.2009 d.48, effective February 2, 2009.
See: 40 N.J.R. 5319(a), 41 N.J.R. 733(b).
In (c)3xxvii, inserted the final sentence; recodified the former second occurrence of (c)3xxiii as
(c)3xxviii; added new (c)4iii; recodified former (c)4iii and (c)4iv as (c)4iv and (c)4v; added new
recodified former (c)4v through (c)4vii as (c)4vii through (c)4ix; added (c)5iii; in (c)8i, inserted
"(N.J.A.C. 5:23-3.15)"; in (c)9iii, deleted "Figure R1003.11 and" following "In"; added new (c)1
recodified former (c)19ix through (c)19xiii as (c)19x through (c)19xiv; and rewrote (c)23iv.
Amended by R.2009 d.126, effective April 20, 2009.
See: 41 N.J.R. 16(a), 41 N.J.R. 1725(a).
Added new (c)4ii; and recodified former (c)4ii through (c)4ix as (c)4iii through (c)4x.
Amended by R.2010 d.195, effective September 7, 2010.
|
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
Vehicle Charging Infrastructure; NF, Alternative Building Thermal Envelope Insu
Value Options; NG, 2024 IECC Stretch Code; NH, Operational Carbon Rating an
Reporting; NI, On-Site Renewable Energy; NJ, Demand Responsive Controls; NK
Electric-Ready Residential Building Provisions; NL, Renewable Energy Infrastruc
Resource A, All-Electric Residential.
iv. Deleted in their entirety: AA, Board of Appeals; AB, Permit Fees; AC, Reserv
Manufactured Housing Used as Dwellings; BC, Accessory Dwelling Units (ADU)
Home Day Care Occupancy; BE Radon Control Methods; BH, Automatic Vehicul
BO, Existing Building and Structures; CC, Recommended Procedure for Safety In
of an Existing Appliance Installation; CD, Piping Standards for Various Applicati
Venting Methods; CF, Sizing of Water Piping System; CG, Nonsewered Sanitatio
Systems; and CH, Private Sewage Disposal.
History
HISTORY:
New Rule, R.1985 d.324, effective July 1, 1985.
See: 17 N.J.R. 861(c), 17 N.J.R. 1646(a).
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1988 d.388, effective August 1, 1988.
See: 20 N.J.R. 1130(a), 20 N.J.R. 2073(b).
Added (c).
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11 Enforcement activities reserved to the Department
Amended by R.2018 d.060, effective January 16, 2018.
See: 49 N.J.R. 1276(a), 50 N.J.R. 310(a).
Added (k).
Administrative correction, effective October 5, 2020.
See: 52 N.J.R. 1822(a).
Amended by R.2020 d.130, effective December 7, 2020.
See: 52 N.J.R. 835(a), 52 N.J.R. 2097(a).
In the introductory paragraph of (a) and (a)8, substituted "at" for "in"; in (a)1, deleted "and subst
following "stations"; and in (a)8, deleted ", and residential health care facilities licensed pursuant
N.J.A.C. 5:27A;" from the end.
Amended by R.2023 d.138, effective December 4, 2023.
See: 55 N.J.R. 1056(a), 55 N.J.R. 2403(a).
In (g), updated the N.J.A.C. reference.
Amended by R.2026 d.069, effective May 18, 2026.
See: 57 N.J.R. 2057(a), 58 N.J.R. 1513(a).
Added (l).
Annotations
Notes
Chapter Notes
Case Notes
Delaware River Port Authority was not subject to Construction Code or anti-discrimination laws
Paralyzed Veterans Ass'n, Inc. v. City of Camden, 111 N.J. 389, 545 A.2d 127 (1988). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
R406.3.3 Joints and penetrations. Joints in walls and floors, joints between the
and floor, and penetrations of the wall and floor shall be made watertight utiliz
approved methods and materials.
R406.4 Subsoil drainage system. Where a hydrostatic pressure condition does
exist, dampproofing shall be provided and a base shall be installed under the fl
drain installed around the foundation perimeter. A subsoil drainage system des
and constructed in accordance with Section R406.1.3 shall be deemed adequat
lowering the ground-water table.
R406.4.1 Floor base course. Floors of basements, except as provided for in Se
R406.1.1, shall be placed over a floor base course not less than 4 inches (102
thickness that consists of gravel or crushed stone containing not more than 10
of material that passes through a No. 4 (4.75 mm) sieve.
Exception: Where a site is located in well-drained gravel or sand/gravel mixt
a floor base course is not required.
R406.4.2 Foundation drain. A drain shall be placed around the perimeter of a
foundation that consists of gravel or crushed stone containing not more than 10
material that passes through a No. 4 (4.75 mm) sieve. The drain shall extend a
minimum of 12 inches (305 mm) beyond the outside edge of the footing. The t
shall be such that the bottom of the drain is not higher than the bottom of the b
under the floor, and that the top of the drain is not less than 6 inches (152 mm)
t |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
be deleted and "4" shall be inserted. Finally, under construction Type IVB for
"12" shall be deleted and "10" shall be inserted.
(20) Under construction Type IB for Group R-2 S, "12" shall be deleted and "
be inserted. Under construction Type IIB for Group R-2 S, "5" shall be deleted
shall be inserted. In addition, under construction Type IIIB for Group R-2 S, "
be deleted and "4" shall be inserted. Finally, under construction Type IVB for
"12" shall be deleted and "10" shall be inserted.
(21) Under construction Type IB for Group R-3 S, "12" shall be deleted and "
be inserted. Under construction Type IIB for Group R-3 S, "5" shall be deleted
shall be inserted. Under construction Type IIIB for Group R-3 S, "5" shall be d
and "4" shall be inserted. In addition, under construction Type IVB for R-3 S,
shall be deleted and "5" shall be inserted. Finally, under construction Type VB
Group R-3 S and S13R, "4" shall be deleted and "3" shall be inserted.
(22) Under construction Type IB for Group R-4 S, "12" shall be deleted and "
be inserted. Under construction Type IIB for Group R-4 S, "5" shall be deleted
shall be inserted. In addition, under construction Type IIIB for Group R-4 S, "
be deleted and "4" shall be inserted. Finally, under construction Type IVB for
"12" shall be deleted and "5" shall be inserted.
(23) Under construction Type IB for Group S-1 NS, "11" shall be deleted and
be inserted and for Group S-1 S, "12" shall be de |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.18 Energy subcode
Amended by R.2026 d.086, effective August 17, 2026.
See: 57 N.J.R. 2354(a), 58 N.J.R. 1898(a).
Rewrote the section.
Annotations
Notes
Chapter Notes
Case Notes
Registered architect retained to sign and seal drawings to comply with permit regulations e
approve as prepared or return for compliance modifications (citing Small Dwelling Energy S
Deck House, Inc. v. New Jersey State Board of Architects, 531 F.Supp. 633 (D.N.J.1982).
Departments of Community Affairs and Energy could not amend state energy subcode. Ne
Builders Ass'n v. Coleman, 227 N.J.Super. 23, 545 A.2d 783 (A.D.1988).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
References to 1989 Supplement added; (b)1ii(5), 2, 4, 8 and 9 amended; (b)5, 6 and 7 added; (c)
Table R-201.2 added.
Amended by R.1991 d.571, effective November 18, 1991.
See: 23 N.J.R. 2619(a), 23 N.J.R. 3444(b).
Added new (c).
Amended by R.1992 d.208, effective May 18, 1992.
See: 24 N.J.R. 680(a), 24 N.J.R. 1879(a).
Code provisions applicable to flood hazard zones clarified.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.2000 d.166, effective April 17, 2000.
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
In (c)4, substituted "more pressure than would be exerted by backfill" for "lateral pressure from
following "subject to" in ii, and substituted "drainage" for "designated disposal" preceding "syste
added "according to the Unified Soil Classification System, Group I Soils" at the end of iii; and in
(c)9iv.
Amended by R.2001 d.369, effective October 15, 2001.
See: 33 N.J.R. 2365(a), 33 N.J.R. 3674(a). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
C
ha
pt
er
Section/Title
Responsibility
Plan Review
Inspection
ing
A117.1 604.2
Building/Plumb
ing
Plumbing
A117.1 604.3
Building/Plumb
ing
Building
A117.1 604.4
Building/Plumb
ing
Plumbing
A117.1 604.5
Building/Plumb
ing
Building
A117.1 604.6
Building/Plumb
ing
Plumbing
A117.1 604.7-604.11.1
Building/Plumb
ing
Building
A117.1 604.11.2
Building/Plumb
ing
Plumbing
A117.1 604.11.3
Building/Plumb
ing
Building
A117.1 604.11.4
Building/Plumb
ing
Plumbing
A117.1 604.11.5
Building/Plumb
ing
Building
A117.1 604.11.6
Building/Plumb
ing
Plumbing
A117.1 604.11.7-605.1
Building/Plumb
ing
Building
A117.1 605.2
Building/Plumb
ing
Plumbing
A117.1 605.3
Building/Plumb
ing
Building
A117.1 605.4
Building/Plumb
ing
Plumbing
A117.1 606.1-606.2
Building/Plumb
ing
Building for clear floor
space/Plumbing for fixture
mounting heights
A117.1 606.3-606.6
Building/Plumb
ing
Plumbing
A117.1 607.1-607.4.2.3
Building/Plumb
ing
Building
A117.1 607.5-607.6
Building/Plumb
Plumbing |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
In addition, Item 2 shall be deleted and in Item 6, "fire code official" shall b
and "fire protection subcode official" shall be inserted.
xxxii. Insert Section 905.4.3 from Section 915.7.1 of the 1996 BOCA National Bu
Code as follows "905.4.3 Location: At each floor level and not more than 5 feet (1
mm) above the floor, there shall be connected to each standpipe a 2 1/2-inch hose
connection with valves and threads compatible with the connections used by the lo
department."
xxxiii. In Section 905.5.3, Class II system 1-inch hose, "fire code official" shall be
and "fire protection subcode official" shall be inserted.
xxxiv. In Section 905.11, Locking standpipe outlet caps, "fire code official" shall
deleted and "fire protection subcode official" shall be inserted.
xxxv. In Section 906.1, Where required, in the exception to Item #1, insert the foll
exception from the 2009 International Building Code: "4. In new Group A, B and
occupancies equipped throughout with quick response sprinklers, portable fire
extinguishers shall be required only in locations specified in Items 2 through 6."
Additionally, in Item #6, "fire code official" shall be deleted and "fire protection s
official" shall be inserted.
xxxvi. In Section 906.5, Conspicuous location, "fire code official" shall be deleted
"fire protection subcode official" shall be inserted.
xlix. Section 907.6.6.3, Termination of monitoring service, shall be deleted.
xxxv. |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11 Enforcement activities reserved to the Department
Amended by R.1992 d.147, effective April 6, 1992.
See: 24 N.J.R. 170(a), 24 N.J.R. 1397(a).
Elevators wholly within R-2 residences exempt.
Amended by R.1992 d.183, effective April 20, 1992.
See: 24 N.J.R. 167(a), 24 N.J.R. 1475(b).
Enforcement of public employees' indoor air quality subcode assigned to DCA.
Amended by R.1994 d.28, effective January 18, 1994.
See: 25 N.J.R. 4546(b), 26 N.J.R. 352(a).
Amended by R.1994 d.96, effective February 22, 1994.
See: 26 N.J.R. 1073(a).
Amended by R.1997 d.377, effective September 15, 1997.
See: 29 N.J.R. 2741(b), 29 N.J.R. 4102(b).
In (g), amended N.J.A.C. references; deleted (g)1; and substantially amended (h).
Amended by R.1997 d.417, effective October 6, 1997.
See: 29 N.J.R. 3387(a), 29 N.J.R. 4285(a).
In (a), inserted "Except as otherwise provided ... and (d),"; added (a)8 and 9; and in (g), amende
N.J.A.C. references.
Amended by R.1999 d.351, effective October 18, 1999.
See: 31 N.J.R. 1838(a), 31 N.J.R. 3082(a).
Added (i).
Amended by R.2000 d.166, effective April 17, 2000.
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
In (a), changed N.J.A.C. reference; and added (j). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
Rewrote (a)1 table, Ch. 10 and Ch. 31, (a)3 table, Ch. 2 and Ch. 6, (a)6 table, Ch. 3, and (d).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.18 Energy subcode
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.143, effective March 20, 1995 (operative July 1, 1995).
See: 26 N.J.R. 4872(a), 27 N.J.R. 1179(b).
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.2001 d.244, effective July 16, 2001 (operative January 16, 2002).
See: 33 N.J.R. 1241(a), 33 N.J.R. 2471(a).
Rewrote the section.
Administrative change.
See: 33 N.J.R. 3310(a).
Administrative correction.
See: 35 N.J.R. 2494(b).
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
In (a)1, substituted "International Code Council, known as the International Energy Conservatio
(IECC/2006)" for "Council of American Building Officials, Inc., known as the Model Energy
Code/1995)"; in (a)1i, substituted "IECC/2006" for "CABO Model Energy Code/1995" and "Inter
Code Council" for "BOCA International"; and rewrote (b).
Amended by R.2009 d.48, effective February 2, 2009.
See: 40 N.J.R. 5319(a), 41 N.J.R. 733(b).
Added new (b)2i, recodified former (b)2i and (b)2ii as (b)2ii as (b)2iii; and added (b)6. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Administrative correction, effective May 2, 2022.
See: 54 N.J.R. 1017(b).
Administrative change, effective July 6, 2022.
See: 54 N.J.R. 1549(a).
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Amended by R.2023 d.112, effective September 18, 2023.
See: 54 N.J.R. 1763(a), 55 N.J.R. 1999(a).
In (b), inserted a comma following "modified"; in (b)10, added new xiv, and recodified exsisting
through lviii as xv through lix.
Administrative correction, effective October 25, 2023.
See: 55 N.J.R. 2322(b).
Amended by R.2023 d.138, effective December 4, 2023.
See: 55 N.J.R. 1056(a), 55 N.J.R. 2403(a).
Rewrote the section.
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a).
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
Added (b)3vi, in (b)5ii(2), (b)5iii(6), (b)5iii(16), and (b)5iv(2), deleted a comma following "IV"
(b)9xxxiii; in (b)19iv1, substituted "adopted by the administrative authority" for "applicability"; a
(b)16xxiii, inserted "D, E or F" ". |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.20 Mechanical subcode
HISTORY:
R.1984 d.314, eff. August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b).
New rule.
Amended by R.1985 d.154, effective April 1, 1985 (operative July 1, 1985).
See: 17 N.J.R. 239(a), 17 N.J.R. 810(a).
(a)2 added; subsection (c) added.
Amended by R.1986 d.380, effective September 22, 1986.
See: 18 N.J.R. 1235(a), 18 N.J.R. 1931(a).
Substantially amended.
Amended by R.1987 d.14, effective January 5, 1987.
See: 18 N.J.R. 2083(a), 19 N.J.R. 63(a).
In (b)5iv Section M-508 was deleted and Section M-508.1 was substituted.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1988 d.270, effective June 20, 1988.
See: 20 N.J.R. 575(a), 20 N.J.R. 1344(a).
Added (a)3 and (c).
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
References to 1989 Supplement added; (c)1 and 3 added.
Amended by R.1990 d.507, effective October 15, 1990. |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.21 One- and two-family dwelling subcode
ii. The definition of "Alteration" shall be deleted.
iii. The definition of "Approved" shall be deleted and the following shall be insert
"Approved refers to approval by the appropriate subcode official or other authority
jurisdiction in accordance with the regulations."
iv. In the definition of "Approved Agency," "or other authority having jurisdiction
accordance with the Uniform Construction Code" shall be inserted after "official."
v. The definition of "Attic, habitable" shall be deleted and the following shall be i
"An attic that has a stairway as a means of access and egress and in which the cei
at a height of seven feet above the attic floor is not more than one-third the area of
floor below."
vi. The definition of "Building" shall be deleted and the following shall be inserte
"BUILDING. A structure enclosed with exterior walls or fire walls, built, ere
framed of component structural parts, designed for the housing shelter, enclo
support of individuals, animals or property of any kind. When used herein, buil
structure shall be interchangeable except where the context clearly indicates other
vii. The definition of "Building, Existing" shall be deleted.
viii. The definition of "Building Line" shall be deleted.
ix. The definitions of "Building Official" and "Change of Occupancy" shall be del
x. In the definition of "Dwelling Unit," "living as a single housekeeping unit" shal
inserted after "person |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Amended by R.2022 d.053, effective April 18, 2022.
See: 53 N.J.R. 105(a), 53 N.J.R. 1553(a), 54 N.J.R. 713(a).
Rewrote (a)1 table, Ch. 31, in (a)6 table, Ch. 3, substituted row "R324.2--Building/Fire/Plumbin
"R324.2-R324.3--Electrical", inserted row for "R324.3"; and in row R324.7, substituted "Electric
for "Building/Fire".
Amended by R.2023 d.029, effective March 6, 2023.
See: 54 N.J.R. 1230(a), 55 N.J.R. 354(a).
Rewrote the section.
Administrative correction, effective September 25, 2023.
See: 55 N.J.R. 2256(a).
Administrative correction, effective December 13, 2023.
See: 56 N.J.R. 139(b).
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
Rewrote (a)1 table, Ch. 10 and Ch. 31, (a)3 table, Ch. 2 and Ch. 6, (a)6 table, Ch. 3, and (d).
Amended by R.2026 d.087, effective August 17, 2026.
See: 57 N.J.R. 2333(a), 58 N.J.R. 1882(a).
Rewrote (a).
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Amended by R.2002 d.215, effective July 1, 2002.
See: 34 N.J.R. 1078(a), 34 N.J.R. 2312(a).
In (b)22, inserted new ii and recodified existing ii through xvii as iii through xviii.
Administrative correction.
See: 34 N.J.R. 3771(b).
Amended by R.2003 d.187, effective May 5, 2003.
See: 34 N.J.R. 4248(a), 35 N.J.R. 1939(c).
Rewrote the section.
Administrative correction.
See: 35 N.J.R. 2864(b).
Amended by R.2003 d.351, effective September 2, 2003.
See: 35 N.J.R. 1177(a), 35 N.J.R. 4051(a).
In (b)9, added xi; recodified existing xi to xiii as xii to xiv.
Amended by R.2003 d.420, effective November 3, 2003.
See: 34 N.J.R. 4248(a), 35 N.J.R. 5073(a).
Rewrote (b).
Administrative correction.
See: 36 N.J.R. 3525(c).
Amended by R.2004 d.423, effective November 15, 2004.
See: 36 N.J.R. 3004(a), 36 N.J.R. 5090(a).
In (b)5, added ii.
Amended by R.2005 d.4, effective January 3, 2005.
See: 36 N.J.R. 4049(a), 37 N.J.R. 47(a). |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.10
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
June 15, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.10 (Reserved)
History
HISTORY:
Amended by R.1987 d.509, effective December 7, 1987.
See: 19 New Jersey Register 1264(a), 19 New Jersey Register 2270(a).
Substantially amended.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 New Jersey Register 2208(a), 22 New Jersey Register 3214(a).
Text conformed to BOCA National Code/1990.
Recodified to 5:23-4.3A by R.1992 d.272, effective July 6, 1992.
See: 24 New Jersey Register 1446(a), 24 New Jersey Register 2424(a).
Section was "Enforcing agency classification".
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Cha
pter
Section/Title
Responsibility
Plan Review
Inspection
electrical items
at Table
N1102.5.1.1)
N1102.5.4-
N1102.5.5
Building/Electrical
Electrical
and related
electrical items
at Table
N1102.5.1.1
N1103.1
Electrical
Electrical
N1103.2
Plumbing
Plumbing
N1103.3
Building
Building
N1103.4
Plumbing
Plumbing
N1103.5.1,
See N1103.5.1.1
See N1103.5.1.1
access
N1103.5.1.1-pump
Plumbing
Plumbing
with integrated
switch
N1103.5.1.1 -
Electrical
Electrical
pump with
non-integrated
switch
N1103.5.1.2
Electrical
Electrical
N1103.5.2-
N1103.5.3
Plumbing
Plumbing
N1103.6
Building
Building
N1103.7
Plumbing
Plumbing
N1103.8
As applicable
As applicable
N1103.9
Electrical
Electrical
N1103.10.1 -
Electrical
Electrical
Switch
N1103.10.1 -
Plumbing
Plumbing
Gas Heater, Pilot
N1103.10.2-
Electrical
Electrical |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
(13) Under construction Type IA for Group H-4 S, "UL" shall be deleted and
be inserted. In addition, under construction Type IIIA for Group H-4 S, "6" sha
deleted and "5" shall be inserted.
(14) Under Occupancy Classifications I-1, Condition 1, I-1, Condition 2, I-2,
the row that begins with NS shall be deleted.
(15) Under construction Type VA for Group I-3 S, "3" shall be deleted and "2
be inserted. In addition, under construction type VB for Group I-3 S, "2" shall
deleted and "NP" shall be inserted.
(16) Under OCCUPANCY CLASSIFICATION, add superscript <"i" >to Gro
addition, the following note shall be added to the table: "i. Child care facilities
IIB, III, IV HT, or V construction shall be limited to 1 story."
(17) Under construction Type IB for Group M NS, "11" shall be deleted and "
be inserted and for Group M S, "12" shall be deleted and "7" shall be inserted.
construction Type IIIA for Group M NS, "4" shall be deleted and "3" shall be i
and for Group M S, "5" shall be deleted and "4" shall be inserted. In addition,
construction Type IVB for M S, "8" shall be deleted and "7" shall be inserted.
under construction Type VA for Group M NS, "3" shall be deleted and "2" sha
inserted and for Group M S, "4" shall be deleted and "3" shall be inserted.
(18) Under Occupancy Classifications R-1, R-2, R-3, and R-4 the row that beg
NS shall be deleted.
(19) Under construction Type IB for Group R-1 S, "12" shall be deleted an |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Cha
pter
Section/Title
Responsibility
Plan Review
Inspection
R301
Building
Building
R302
Building/Fire
Building (except
penetrations in existing
membranes for electrical
outlets or devices
pursuant to Sections
R302.4 through R302.4.2
which shall be
electrical)
R303
Building/Fire
Building
R304-R305
Building
Building
R306, except
Building
Building
R306.1.6 and
R306.1.7
R306.1.6
As applicable based on
As applicable based
equipment
on equipment
R306.1.7
Plumbing
Plumbing
R308
Fire
Fire
<
R309
Fire<2>
Fire<2>
>
R310.1-R310.5
Fire
Fire
R310.6
Electrical/Fire
Electrical
R310.7-R311.5
Fire
Fire
R311.6
Electrical/Fire
Electrical
R311.7
Fire
Fire
R312-R313
Building
Building
R314-R315
Building/Fire
Building
R317.1-R317.3
Building
Building
R317.4
Electrical
Electrical
R317.5
Fire
Fire
R317.6
Electrical
Electrical
R317.7
Building
Building
R318-R321
Building/Fire
Building
R324-R326
Building
Building |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
or any other person, firm or corporation, directly or indirectly in control of a buildi
structure or real property and shall include any subdivision thereof of the State."
xxiv. The definition of "peer review" shall be deleted.
xxv. The definitions of "permit" and "person" shall be deleted.
xxvi. A definition of "radioactive material" shall be inserted as follows:
"RADIOACTIVE MATERIAL. Any material or combination of mater
spontaneously emit ionizing radiation."
xxvii. The definition of "Registered Design Professional in Responsible Charge" s
deleted.
xxviii. The definition of the "Relocatable Building" shall be deleted.
xxix. The definition of "repair" shall be deleted.
xxx. The definition of the "residential health care facility" shall be inserted as foll
"RESIDENTIAL HEALTH CARE FACLILITY. A facility not located with, and
by, a licensed health care facility that provides food, shelter, supervised health
related services, in a homelike setting, to four or more persons 18 years of age or o
are unrelated to the owner or administrator."
xxxi. The definition of "rooming house" shall be inserted as follows: "ROOMING
HOUSE: A building arranged or used for single occupancy where no meals or pers
financial services are provided to the residents. For the purposes of applying this d
personal services shall mean, any services permitted or required to be furnished by
owner or operator to a resident, other than shelter, i |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.7 Municipal approvals of alternative materials, equipment, or methods of construction
he may approve its use subject to the requirements of the regulations. The cost of all tests,
and investigations required under these provisions shall be paid by the applicant.
(c) Research reports: The appropriate subcode official may accept, as supporting data to a
this determination, duly authenticated research reports from approved authoritative source
materials or assemblies proposed for use which are not specifically provided for in the reg
History
HISTORY:
Amended by R.1992 d.390, effective October 5, 1992.
See: 24 New Jersey Register 1844(a), 24 New Jersey Register 3515(b).
Reference to exception in 3.8 added.
Amended by R.2003 d.384, effective October 6, 2003.
See: 35 New Jersey Register 2422(a), 35 New Jersey Register 4712(a).
Rewrote (a).
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3, Appx. 3-A
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
August 17, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
APPENDIX 3-A
APPENDIX
NEW JERSEY DEPARTMENT OF COMMUNITY AFFAIRS
DIVISION OF CODES AND STANDARDS
CODE CHANGE PROPOSAL
REHABILITATION SUBCODE (N.J.A.C. 5:23-6)
Proposals must be presented with language proposed for deletion in brackets[].
Proposals must be presented with language proposed for addition underlined:
Mail code change proposals to:
Fax code change proposals to:
Code Development Unit
Code Development Unit
Department of Community Affairs
(609) 633-6729
Division of Codes and Standards
PO Box 802
Trenton, New Jersey 08625
Direct questions to the Code Development or Code Assistance Units at (609) 984-7609.
Section (citation) proposed for change: ____________________
Sections (companion changes) that might also need to be changed:
____________________
NAME: ____________________
ORGANIZATION (if any): ____________________
ADDRESS: ____________________
____________________
TELEPHONE: ____________________ FAX: ____________________ E-mail: ____________________
Proposed Code Change:
____________________ |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
a means of egress door opening directly to an exit or to an exterior exit
that leads directly to an exit.
xlvii. In Section 907.4.2.5, Protective covers, "fire code official" shall be deleted a
protection subcode official" shall be inserted.
xlviii. Section 907.5.2.2.5, Standby power, shall be deleted, and Section 907.5.2.2
IBC/2018 shall be inserted as follows: Section 907.5.2.2.5, Emergency power.
Emergency voice/alarm communications systems shall be provided with emergenc
in accordance with Section 2702. The system shall be capable of powering the req
load for a duration of not less than 24 hours, as required in NFPA 72.
xlix. In Section 907.6.6.2, MIY Monitoring, "fire code official" shall be deleted a
protection subcode official" shall be inserted.
l. Section 907.6.6.3, Termination of monitoring service, shall be deleted.
li. In Section 909.5.2, Testing of leakage area, "fire code official" shall be deleted
protection subcode official" shall be inserted.
lii. In Section 909.7, Airflow design method, "fire code official" shall be deleted a
protection subcode official" shall be inserted.
liii. In Section 909.8, Exhaust method, "fire code official" shall be deleted and "fir
protection subcode official" shall be inserted.
liv. In Section 909.9, Design fire, "fire code official" shall be deleted and "fire pro
subcode official" shall be inserted.
lv. In Section 909.10, Equipment, "fire code official" s |
- |
pdf_text |
| full-text |
Page 41 of 57
§ 5:23-3.4 Responsibilities
Cha
pter
Section/Title
Responsibility
Inspection
Plan Review
G2412-G2424
Plumbing
Plumbing
G2425.1-G2425.2
Building/Fire
Fire
G2425.3
Building/Fire
Building
G2425.4-G2425.6
Building/Fire
Fire
G2425.7
Building/Fire
Building
G2425.8-G2425.10
Building/Fire
Fire
G2425.11
Building/Fire
Building
G2425.12-G2425.15.1
Building/Fire
Fire
G2425.15.2
Fire
Fire
G2425.15.3
Building/Fire
Building
G2425.15.4-G2427.5.1
Building/Fire
Fire
G2427.5.2
Building/Fire
Building
G2427.5.3-G2427.5.6.4
Building/Fire
Fire
G2427.5.7
Building
Building
G2427.5.9
Building/Fire
Fire
G2427.5.10
Building/Fire
Fire
G2427.6-G2427.8
Building/Fire
Fire
G2427.9
Plumbing
Plumbing
G2427.10.1-G2430.1
Building/Fire
Fire
G2430.2
Building/Fire
Building
G2432-G2434
Plumbing/Fire
Plumbing
G2435
Plumbing/Fire
Fire
G2436-G2440.3
Building/Fire
Building |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.5 Posting structures
See: 21 N.J.R. 2783(a), 21 N.J.R. 3460(a).
Added reference to E Use Group (educational facilities) at (b).
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.2000 d.47, effective February 7, 2000.
See: 31 N.J.R. 2314(a), 32 N.J.R. 443(a).
Added (f).
Amended by R.2000 d.166, effective April 17, 2000.
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
Rewrote (d) and (e).
Amended by R.2009 d.48, effective February 2, 2009.
See: 40 N.J.R. 5319(a), 41 N.J.R. 733(b).
In (a), substituted "chapter 3" for "article 2".
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Amended by R.2018 d.153, effective August 20, 2018.
See: 49 N.J.R. 2332(a), 50 N.J.R. 1888(a).
Added new (b)10ii13 and (b)10l, recodified former (b)10ii13 through (b)10ii20 as (b)10ii14 thro
(b)10ii21; rewrote (b)10vi and (b)10xxxviii; and recodified former (b)10l through (b)10lii as (b)1
through (b)10liii.
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Amended by R.2021 d.004, effective January 4, 2021.
See: 52 N.J.R. 385(a), 53 N.J.R. 47(a).
Rewrote (b).
Amended by R.2022 d.022, effective February 7, 2022.
See: 53 N.J.R. 1133(a), 54 N.J.R. 263(a).
Rewrote (b)2; added (b)4x; recodified former (b)4x and (b)4xi as (b)4xi and (b)4xii; added (b)8
recodified former (b)8vi through (b)8xlv as (b)8vii through (b)8xlvi; deleted former (b)10iii6; an
recodified former (b)10iii7 through (b)10iii22 as (b)10iii6 through (b)10iii21.
Administrative correction, effective May 2, 2022.
See: 54 N.J.R. 1017(b).
Administrative change, effective July 6, 2022.
See: 54 N.J.R. 1549(a).
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Amended by R.2023 d.112, effective September 18, 2023. |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
related services, in a homelike setting, to four or more persons 18 years of age or o
are unrelated to the owner or administrator."
xxxiv. The definition of "rooming house" shall be inserted as follows: "ROOMIN
HOUSE: A building arranged or used for single occupancy where no meals or pers
financial services are provided to the residents. For the purposes of applying this d
personal services shall mean, any services permitted or required to be furnished by
owner or operator to a resident, other than shelter, including but not limited to, me
other food services, and assistance in dressing, bathing or attending to other person
needs."
xxxv. The definition of "single residential occupancy" shall be inserted as follows
"SINGLE RESIDENTIAL OCCUPANCY: A building arranged or used for i
non-transient residency by persons living independently of one another, rega
whether the residents share the use of common facilities, such as kitchen or
facilities."
xxxvi. In the definition of "Special Inspector," "building official" shall be deleted
"construction official" shall be inserted. Additionally, the following sentence shall
added: "Special inspectors shall be certified in accordance with the administrative
provisions of the Uniform Construction Code."
xxxvii. The definition of "structure" shall be deleted and the following shall be ins
"STRUCTURE. A combination of materials to form a construction for occupancy,
ornamentation, whether instal |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
Added new (c)3vii; deleted former (c)3xxii; recodified former (c)3vii through (c)3xxi as (c)3viii
(c)3xxii; added new (c)19xii; and recodified former (c)19xii through (c)19xv as (c)19xiii through
(c)19xvi.
Special amendment, R.2014 d.161, effective October 1, 2014 (to expire May 12, 2015).
See: 46 N.J.R. 2186(a).
Rewrote (c)3.
Adopted concurrent amendment, R.2015 d.077, effective April 15, 2015.
See: 46 N.J.R. 2186(a), 47 N.J.R. 989(b).
Provisions of R.2014 d.161 adopted without change.
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Administrative correction.
See: 47 N.J.R. 2753(a).
Amended by R.2019 d.083, effective August 5, 2019.
See: 51 N.J.R. 3(a), 51 N.J.R. 1269(a).
In (c)3xl, inserted "new" and "and 'relocated' shall be inserted in lieu thereof".
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Amended by R.2021 d.004, effective January 4, 2021.
See: 52 N.J.R. 385(a), 53 N.J.R. 47(a). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
In (b)19, added new iv and recodified former iv and v as v and vi.
Administrative correction.
See: 37 N.J.R. 502(b), 674(a).
Amended by R.2005 d.403, effective November 21, 2005.
See: 37 N.J.R. 2753(a), 37 N.J.R. 4399(b).
Added (b)14xi and recodified former (b)14xi-xiii as (b)14xii-xiv; added (b)18 and recodified for
(b)18-25 as (b)19-26.
Amended by R.2005 d.446, effective December 19, 2005.
See: 37 N.J.R. 2747(a), 37 N.J.R. 4907(a).
In (b)3viii(3), substituted "one- and two-family" for "single-family"; in (b)3viii(5), "Group R-5
includes: ..."
Amended by R.2006 d.28, effective January 17, 2006.
See: 37 N.J.R. 2750(a), 38 N.J.R. 485(b).
Rewrote (b)9, 20 and 21.
Amended by R.2006 d.157, effective May 1, 2006.
See: 37 N.J.R. 3108(a), 38 N.J.R. 1824(a).
Rewrote (b)21ii.
Administrative Correction.
See: 38 N.J.R. 3024(a).
Amended by R.2006 d.381, effective November 6, 2006.
See: 38 N.J.R. 35(a), 38 N.J.R. 4691(a).
In (b)15ii, added the last sentence; added new (b)15iv; and recodified former (b)15iv through (b
(b)15v through (b)15xvi. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.2 Matters covered; exceptions
See: 42 N.J.R. 1943(a), 42 N.J.R. 3053(a).
In (d)12ii, substituted "1021.1 and 1021.2" for "1019.1 and 1019.2".
Amended by R.2011 d.270, effective November 7, 2011.
See: 43 N.J.R. 1297(a), 43 N.J.R. 2999(a).
In (b)1 and (b)2, substituted "Design and Construction of Health Care" for "Construction and Eq
of Hospital and Medical"; in (b)1, substituted "Facilities Guidelines Institute" for "American Insti
Architects Committee on Architecture for Health" and deleted "1996-1997 edition or" preceding
"current"; in (b)2, inserted "and Senior Services"; and rewrote (b)3.
Amended by R.2015 d.078, effective May 18, 2015.
See: 46 N.J.R. 1768(a), 47 N.J.R. 990(a).
In the introductory paragraph of (d)4, substituted "iii" for "iv"; deleted former (d)4iv; and recodi
(d)4v as (d)4iv.
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In (d)12i, substituted "1017" for "1016"; in (d)12ii, substituted "1006" for "1021.1" and "1007" f
"1021.2"; in (d)12iii, substituted "1013" for "1011"; and in (d)12iv, substituted "1008" for "1003.
and "(d)8" for "(d)7".
Amended by R.2018 d.153, effective August 20, 2018.
See: 49 N.J.R. 2332(a), 50 N.J.R. 1888(a).
In (b)1, inserted the second sentence; in (b)2, deleted "and Senior Services" following the first
occurrence of "Health"; in (d)12vi, substituted "Fire" for "Lightning protection of the type require
structure b |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
Rewrote the section.
Amended by R.2008 d.274, effective September 15, 2008.
See: 40 N.J.R. 2629(a), 40 N.J.R. 5195(b).
In paragraph 7.23 of (b)8vi, substituted "Spas and Hot Tubs" for "spas and hot tubs"; in subpara
of paragraph 7.23.3 of (b)8vi, inserted a period at the end; in paragraph 7.23.4.1 of (b)8vi, added t
second paragraph; and in paragraph 7.23.5 of (b)8vi, inserted the closing quotation mark at the en
Amended by R.2008 d.346, effective November 17, 2008.
See: 40 N.J.R. 3778(a), 40 N.J.R. 6540(a).
In (b)4iv, inserted "the" preceding "Construction" and substituted "2004" for "1998"; added (b)1
recodified former (b)10vi and (b)10vii as (b)10vii and (b)10viii; and in (b)10viii, substituted "200
"1999".
Amended by R.2009 d.48, effective February 2, 2009.
See: 40 N.J.R. 5319(a), 41 N.J.R. 733(b).
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote the section.
Amended by R.2013 d.081, effective June 3, 2013.
See: 44 N.J.R. 1303(a), 45 N.J.R. 1393(a).
Added new (b)3viii; recodified former (b)3viii through (b)3ix as (b)3ix through (b)3x; added ne
through (b)17iii; and recodified former (b)17ii through (b)17viii as (b)17iv through (b)17x.
Amended by R.2016 d.001, effective January 4, 2016.
See: 47 N.J.R. 2021(a), 48 N.J.R. 43(a).
Rewrote the section.
Amended by R.2018 d.021, effective January 16, 2018. |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
i. The definition of "addition," shall be deleted.
ii. In the definition of agricultural buildings, "A structure qualifying under the Uni
Construction Code definition of a Commercial Farm Building may be built accordi
the regulations at N.J.A.C. 5:23-3.2(d)" shall be inserted after the last sentence.
iii. The definition of "alteration" shall be deleted.
iv. The definition of "approved" is modified to add the words "or other appropriat
subcode official" after the words "building official."
v. The definition of "building" shall be deleted and the following shall be inserted
"BUILDING. A structure enclosed with exterior walls or fire walls, built, erected a
framed of component structural parts, designed for the housing shelter, enclosure a
support of individuals, animals or property of any kind. When used herein, buildin
structure shall be interchangeable except where the context clearly indicates other
vi. The definition of "building line" shall be deleted.
vii. The definition of "building official" shall be deleted and the following shall be
inserted: "BUILDING SUBCODE OFFICIAL. A qualified person appointed by th
municipal appointing authority or the commissioner pursuant to the act and the reg
to enforce the provisions of the building subcode within the jurisdiction of the enf
agency."
viii. The definition of "change of occupancy" shall be deleted.
ix. The definition of "deferred submittal" shall be deleted.
x. In the |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
See: 53 N.J.R. 512(a).
Administrative correction, effective March 2, 2021.
See: 53 N.J.R. 512(b).
Administrative correction, effective April 12, 2021.
See: 53 N.J.R. 775(a).
Administrative correction, effective April 26, 2021.
See: 53 N.J.R. 999(a).
Amended by R.2022 d.022, effective February 7, 2022.
See: 53 N.J.R. 1133(a), 54 N.J.R. 263(a).
In (a)1 and (a)6, table rows ISPSC, Section 305, deleted "Exception 1" preceding "which"; in (a)
inserted the row for "301.19"; and in (a)6 table, inserted the row for "M1307.7".
Amended by R.2022 d.053, effective April 18, 2022.
See: 53 N.J.R. 105(a), 53 N.J.R. 1553(a), 54 N.J.R. 713(a).
Rewrote (a)1 table, Ch. 31, in (a)6 table, Ch. 3, substituted row "R324.2--Building/Fire/Plumbin
"R324.2-R324.3--Electrical", inserted row for "R324.3"; and in row R324.7, substituted "Electric
for "Building/Fire".
Amended by R.2023 d.029, effective March 6, 2023.
See: 54 N.J.R. 1230(a), 55 N.J.R. 354(a).
Rewrote the section.
Administrative correction, effective September 25, 2023.
See: 55 N.J.R. 2256(a).
Administrative correction, effective December 13, 2023.
See: 56 N.J.R. 139(b). |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.19
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
August 17, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.19 (Reserved)
History
HISTORY:
Amended by R.1982 d.7, eff. February 1, 1982.
See: 13 N.J.R. 171(a), 14 N.J.R. 142(a).
This section was recodified from 5:23-3.9.
Repealed by R.2019 d.083, effective August 5, 2019.
See: 51 N.J.R. 3(a), 51 N.J.R. 1269(a).
Section was "Manufactured home subcode".
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
Amended by R.1998 d.136, effective March 16, 1998.
See: 30 N.J.R. 4(a), 30 N.J.R. 1038(a).
In (b)9, added xii.
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.2001 d.340, effective September 17, 2001.
See: 33 N.J.R. 1245(a), 33 N.J.R. 3308(b).
Rewrote the section.
Amended by R.2002 d.393, effective December 16, 2002.
See: 34 N.J.R. 2914(a), 34 N.J.R. 4428(a).
In (b)8, deleted former (ii) and recodified existing (iii) to (ix) as (ii) to (viii).
Amended by R.2005 d.35, effective January 18, 2005.
See: 36 N.J.R. 3329(b), 37 N.J.R. 267(a).
Rewrote the section.
Administrative correction.
See: 37 N.J.R. 885(a).
Amended by R.2005 d.341, effective October 17, 2005.
See: 37 N.J.R. 164(a), 37 N.J.R. 3974(b).
In (b)3iv, added "and add the following sentence at the end: 'Minimum earth cover for building s
connected to a private sewage disposal system shall be 6 inches.' " at the end of the paragraph.
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In (a)2 table row 10.5.9, updated the "Inspection Responsibility"; in (a)4, International Energy
Conservation Code table, deleted the row for "R403.2"; in (a)6 table, deleted the row for "N1103.
rewrote (d).
Amended by R.2018 d.153, effective August 20, 2018.
See: 49 N.J.R. 2332(a), 50 N.J.R. 1888(a).
In the table in (a)1, rewrote entries in "Ch. 7" and "Ch. 31"; and in the table in (a)6, rewrote entr
"R302" and "R326".
Amended by R.2020 d.119, effective November 2, 2020.
See: 52 N.J.R. 371(a), 52 N.J.R. 1999(a).
Rewrote the tables in (a)1, (a)2, and (a)4 through (a)7.
Administrative correction, effective February 23, 2021.
See: 53 N.J.R. 512(a).
Administrative correction, effective March 2, 2021.
See: 53 N.J.R. 512(b).
Administrative correction, effective April 12, 2021.
See: 53 N.J.R. 775(a).
Administrative correction, effective April 26, 2021.
See: 53 N.J.R. 999(a).
Amended by R.2022 d.022, effective February 7, 2022.
See: 53 N.J.R. 1133(a), 54 N.J.R. 263(a).
In (a)1 and (a)6, table rows ISPSC, Section 305, deleted "Exception 1" preceding "which"; in (a)
inserted the row for "301.19"; and in (a)6 table, inserted the row for "M1307.7". |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
installed around the portion of the perimeter where the basement floor is below
level. The provisions of Sections R406.3 and R406.4.1 shall not apply in this c
R406.1.2 Under-floor space. The finished ground level of an under-floor spac
a crawl space shall not be located below the bottom of the footings. Where ther
evidence that the ground water table rises to within 6 inches (152 mm) of the g
level at the outside building perimeter, or that the surface water does not readil
from the building site, the ground level of the under-floor space shall be as hig
outside finished ground level, unless an approved drainage system is provided.
provisions of Sections R406.2, R406.3 and R406.4 shall not apply in this case.
R406.1.2.1 Flood hazard areas. For buildings and structures in flood hazard ar
established in Section R322, the finished ground level of an under-floor space
crawl space shall be equal to or higher than the outside finished ground level o
one side.
Exception: Under-floor spaces that meet the requirements of FEMA TB-11.
R406.1.3 Ground-water control. Where the groundwater table is lowered and
maintained at an elevation not less than 6 inches (152 mm) below the bottom o
lowest floor, the floor and walls shall be dampproofed in accordance with Sect
R406.2. The design of the system to lower the ground-water table shall be base
accepted principles of engineering that shall consider, but not necessarily be li
|
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Amended by R.2000 d.166, effective April 17, 2000.
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
In (b)2, changed Chapter 21 and Chapter 31 through 33 references in the Building Subcode, and
Chapter 12 reference in the Mechanical Subcode; and in (d)2, deleted a former Chapter 21 referen
Building Subcode, and changed Chapter 12 reference in the Mechanical Subcode.
Amended by R.2001 d.141, effective May 7, 2001.
See: 32 N.J.R. 3917(a), 33 N.J.R. 746(a), 33 N.J.R. 1399(d).
In (b)1 and (b)2, deleted "as follows: (All except M-801.2)" following "Chapter 8" in the Mecha
Code; in (d)1, deleted "Chapter 8 as follows: M-801.2" in the Mechanical Code; in (d)2, deleted "
following "413.5.2", inserted "3305.0" following "414.5", and deleted "408.3.1", "3305.0" and "4
the end of the Building Subcode, and deleted "Chapter 8 as follows: M-801.2" in the Mechanical
Subcode.
Amended by R.2001 d.196, effective June 18, 2001.
See: 33 N.J.R. 6(a), 33 N.J.R. 2090(a).
In (a)1, (a)2, (b)1, (b)2, (d)1 and (d)2, rewrote Mechanical Subcode and inserted Fuel Gas Subc
Amended by R.2001 d.244, effective July 16, 2001 (operative January 16, 2002).
See: 33 N.J.R. 1241(a), 33 N.J.R. 2471(a).
In "ENERGY SUBCODE" categories of (a) through (c), listed specific sections of Chapters 5 an
relating to building subcode official responsibility.
Administrative correction.
See: 33 N.J.R. 3308(a).
Amended by R. |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.17 Fire protection subcode
History
HISTORY:
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1984 d.314, effective August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b).
Section substantially amended.
Amended by R.1986 d.380, effective September 22, 1986.
See: 18 N.J.R. 1235(a), 18 N.J.R. 1931(a).
Substantially amended.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
Reference to 1989 Supplement added; (a)1i(7) amended.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1998 d.332, effective July 6, 1998. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Article 26 amended at (b)14.
Amended by R.1991 d.429, effective August 19, 1991.
See: 23 N.J.R. 1487(a), 23 N.J.R. 2501(a).
In (a), added 3. Added (c).
Amended by R.1992 d.244, effective June 15, 1992.
See: 24 N.J.R. 1147(a), 24 N.J.R. 2243(a).
Text added at (b)10v through viii.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.144, effective March 20, 1995 (operative July 1, 1995).
See: 26 N.J.R. 2698(a), 26 N.J.R. 3524(a), 27 N.J.R. 1180(a).
Amended by R.1995 d.477, effective September 5, 1995.
See: 27 N.J.R. 1717(a), 27 N.J.R. 3328(a).
Added (b)2v.
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.2000 d.492, effective December 18, 2000.
See: 32 N.J.R. 3219(a), 32 N.J.R. 4437(b).
Rewrote (b)25.
Amended by R.2001 d.127, effective April 16, 2001.
See: 33 N.J.R. 392(a), 33 N.J.R. 1195(a).
In (a)9, added new ix and recodified former ix through xiii as new x through xiv. |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.16 Electrical subcode
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.1998 d.362, effective July 20, 1998.
See: 30 N.J.R. 1122(a), 30 N.J.R. 2644(b).
In (a), inserted a new 3.
Amended by R.2000 d.48, effective February 7, 2000.
See: 31 N.J.R. 2317(a), 32 N.J.R. 445(a).
In (a), substituted references to 1999 for references to 1996 throughout, substituted a reference t
Batterymarch Park for a reference to Batterymarch Park in 1i, and inserted 2i; and in (b), inserted
inserted a new 3, recodified former 3 and 4 as 4 and 5, substituted a reference to line four for a ref
to line three and substituted a reference to line six for a reference to line five in the new 4i, and su
a reference to section 500-5(a)(4) for a reference to section 500-3(a)4 in the new 5i.
Amended by R.2003 d.187, effective May 5, 2003.
See: 34 N.J.R. 4248(a), 35 N.J.R. 1939(c).
Rewrote the section.
Amended by R.2003 d.240, effective June 16, 2003.
See: 34 N.J.R. 3045(a), 35 N.J.R. 2637(c).
Added (c).
Amended by R.2006 d.158, effective May 1, 2006.
See: 37 N.J.R. 4105(a), 38 N.J.R. 1827(a).
In (a)1, (a)2 and (a)2.i, substituted "2005" for "2002"; also in (a)2.i, substituted "#06-2" for "#03
(a)3, substituted "C2-2002" for "C2-l997"; deleted (b)1 and recodified (b)2 through (b)6 as (b)1 t |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.8 Products violating the Code
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1997 d.508, effective December 1, 1997.
See: 29 N.J.R. 3762(a), 29 N.J.R. 5062(a).
In (d)2i, added reference to CSA/NRTL standards; in (d)3i, added the exception for transition gl
inserted (d)3vi.
Recodified from N.J.A.C. 5:23-3.8A by R.2003 d.384, effective October 6, 2003.
See: 35 N.J.R. 2422(a), 35 N.J.R. 4712(a).
Former N.J.A.C. 5:23-3.8, Department approval of nonconforming materials, repealed.
Amended by R.2007 d.310, effective October 1, 2007.
See: 39 N.J.R. 135(a), 39 N.J.R. 4113(b).
In (d)2i, updated the National Electrical Code references, deleted "/Nationally Recognized Testi
Laboratory" following "Canadian Standards Association" and "/NRTL" following "CSA", and ins
last sentence.
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In (d)1i, substituted "803.1" for "803.2"; and in (d)1ii, substituted "804" for "805.2".
Amended by R.2023 d.030, effective March 6, 2023.
See: 54 N.J.R. 1661(a), 55 N.J.R. 349(a).
In (d)1i and (d)1ii, substituted "Section" for "section"; in (d)1i, inserted "or other equivalent stan
and (d)1ii, inserted ", or other equivalent standards".
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.17 Fire protection subcode
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
In the introductory paragraph of (a)1, substituted "fuel gas, and one- and two-family dwelling su
to the extent delineated in N.J.A.C. 5:23-3.4, as the fire protection subcode for New Jersey" for "a
gas"; and added (a)1v.
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
ii. In the definition of agricultural buildings, "A structure qualifying under the Uni
Construction Code definition of a Commercial Farm Building may be built accordi
the regulations at N.J.A.C. 5:23-3.2(d)" shall be inserted after the last sentence.
iii. The definition of "alteration" shall be deleted.
iv. The definition of "ambulatory care facility" shall be amended as follows: the p
"who are rendered incapable of self-preservation by the services provided or staff
accepted the responsibility for care recipients already incapable" shall be deleted a
"where evacuation is impractical" shall be inserted.
v. The definition of "approved" is modified to add the words "or other appropriate
official" after the words "building official."
vi. The definition of "building" shall be deleted and the following shall be inserted
"BUILDING. A structure enclosed with exterior walls or fire walls, built, erected a
framed of component structural parts, designed for the housing shelter, enclosure a
support of individuals, animals or property of any kind. When used herein, buildin
structure shall be interchangeable except where the context clearly indicates other
vii. The definition of "building line" shall be deleted.
viii. The definition of "building official" shall be deleted and the following shall b
inserted: "BUILDING SUBCODE OFFICIAL. A qualified person appointed by th
municipal appointing authority or the commissioner pursuant to the act |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11B Underground storage tank systems
In (d)3, deleted "with a capacity of 2000 gallons or less" following "Tanks".
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
Added (c).
Amended by R.1990 d.58, effective February 5, 1990.
See: 21 N.J.R. 3346(a), 22 N.J.R. 351(a).
Added (d) adopting the 1989 Supplement to the 1987 National Standard Plumbing Code.
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
Text added at (a)3; (d)3ii amended.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1991 d.326, effective July 1, 1991.
See: 23 N.J.R. 804(a), 23 N.J.R. 2044(a).
GPF set at 1.6; gravity water closets not permitted in commercial uses.
Amended by R.1991 d.571, effective November 18, 1991.
See: 23 N.J.R. 2619(a), 23 N.J.R. 3444(b).
Added new (c).
Amended by R.1992 d.67, effective February 3, 1992.
See: 23 N.J.R. 3602(a), 24 N.J.R. 404(b).
Low volume water closet exception added at (b)18i(1).
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.122, effective March 6, 1995 (operative July 1, 1995).
See: 26 N.J.R. 4874(a), 27 N.J.R. 894(a). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11 Enforcement activities reserved to the Department
Amended by R.2018 d.060, effective January 16, 2018.
See: 49 N.J.R. 1276(a), 50 N.J.R. 310(a).
Added (k).
Administrative correction, effective October 5, 2020.
See: 52 N.J.R. 1822(a).
Amended by R.2020 d.130, effective December 7, 2020.
See: 52 N.J.R. 835(a), 52 N.J.R. 2097(a).
In the introductory paragraph of (a) and (a)8, substituted "at" for "in"; in (a)1, deleted "and subst
following "stations"; and in (a)8, deleted ", and residential health care facilities licensed pursuant
N.J.A.C. 5:27A;" from the end.
Amended by R.2023 d.138, effective December 4, 2023.
See: 55 N.J.R. 1056(a), 55 N.J.R. 2403(a).
In (g), updated the N.J.A.C. reference.
Amended by R.2026 d.069, effective May 18, 2026.
See: 57 N.J.R. 2057(a), 58 N.J.R. 1513(a).
Added (l).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
In the table at (a)1, rewrote entries in "Ch. 4", "Ch. 16", "Ch. 30" and "Ch. 31", and in entries "C
and "Ch. 6", inserted "/Fire" in the third column; in the table at (a)2, deleted entry "Ch. 17" and a
entries "Ap. J", "Ap. K" and "Ap. L"; rewrote tables at (a)4, (a)5 and (a)6; and in the table at (a)7,
"Ch. 6", inserted entry "635" and rewrote entry "Ch.7".
Amended by R.2009 d.51, effective February 2, 2009.
See: 40 N.J.R. 5325(a), 41 N.J.R. 738(a).
In the table in (a)1, in the entry for "Ch. 9", inserted "909.12.1 and 910.4.4" in column "Section/
and, under the sub-headings "Plan Review" and "Inspection" under column "Responsibility", inse
"(except 909.12.1 and 910.4.4)" following "Fire" and inserted "Fire/Electric"; and in (c), updated
N.J.A.C. reference.
Amended by R.2011 d.269, effective November 7, 2011.
See: 43 N.J.R. 904(a), 43 N.J.R. 3008(a).
Rewrote the tables in (a)1 through (a)7.
Amended by R.2013 d.081, effective June 3, 2013.
See: 44 N.J.R. 1303(a), 45 N.J.R. 1393(a).
In the table in (a)6, for the "Appx G" entry, substituted "105.1-105.4" for "105" and inserted "10
under the "Section/Title" heading, and under the sub-headings "Plan Review" and "Inspection" un
column "Responsibility", inserted "Electrical".
Amended by R.2015 d.029, effective February 17, 2015.
See: 46 N.J.R. 1507(a), 47 N.J.R. 459(a).
In the introductory paragraph of (d), inserted ", or stand-by power generators |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.22 Fuel gas subcode
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
In the introductory paragraph of (b), inserted a comma following "sections"; and added (b)4iv.
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.9 Interpretations and opinions
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
Rewrote the section.
Amended by R.2002 d.393, effective December 16, 2002.
See: 34 N.J.R. 2914(a), 34 N.J.R. 4428(a).
In (b)8, deleted former (ii) and recodified existing (iii) to (ix) as (ii) to (viii).
Amended by R.2005 d.35, effective January 18, 2005.
See: 36 N.J.R. 3329(b), 37 N.J.R. 267(a).
Rewrote the section.
Administrative correction.
See: 37 N.J.R. 885(a).
Amended by R.2005 d.341, effective October 17, 2005.
See: 37 N.J.R. 164(a), 37 N.J.R. 3974(b).
In (b)3iv, added "and add the following sentence at the end: 'Minimum earth cover for building s
connected to a private sewage disposal system shall be 6 inches.' " at the end of the paragraph.
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
Rewrote the section.
Amended by R.2008 d.274, effective September 15, 2008.
See: 40 N.J.R. 2629(a), 40 N.J.R. 5195(b).
In paragraph 7.23 of (b)8vi, substituted "Spas and Hot Tubs" for "spas and hot tubs"; in subpara
of paragraph 7.23.3 of (b)8vi, inserted a period at the end; in paragraph 7.23.4.1 of (b)8vi, added t
second paragraph; and in paragraph 7.23.5 of (b)8vi, inserted the closing quotation mark at the en
Amended by R.2008 d.346, effective November 17, 2008.
See: 40 N.J.R. 3778(a), 40 N.J.R. 6540(a). |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.20 Mechanical subcode
New rule.
Amended by R.1985 d.154, effective April 1, 1985 (operative July 1, 1985).
See: 17 N.J.R. 239(a), 17 N.J.R. 810(a).
(a)2 added; subsection (c) added.
Amended by R.1986 d.380, effective September 22, 1986.
See: 18 N.J.R. 1235(a), 18 N.J.R. 1931(a).
Substantially amended.
Amended by R.1987 d.14, effective January 5, 1987.
See: 18 N.J.R. 2083(a), 19 N.J.R. 63(a).
In (b)5iv Section M-508 was deleted and Section M-508.1 was substituted.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1988 d.270, effective June 20, 1988.
See: 20 N.J.R. 575(a), 20 N.J.R. 1344(a).
Added (a)3 and (c).
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
References to 1989 Supplement added; (c)1 and 3 added.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1991 d.429, effective August 19, 1991. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
lxxxvi. In 915.1.4, Fuel-burning appliances outside of dwelling units, sleeping uni
classrooms, in the title, in the section and in exceptions 1 and 2, the word "and" sh
deleted before "classrooms" and the words "or any other occupiable space(s)" shall
added following "classrooms." Additionally, in exception 2.1, the word "or" shall
deleted before "classrooms" and the words "or any other occupiable space(s)" shall
added following "classrooms."
lxxxvii. In 915.1.5, Private garages, and in exceptions 1 and 2, the word "and" sha
deleted before "classrooms" and the words "or any other occupiable space(s)" shall
added following "classrooms." Additionally, in exception 4, the word "or" shall be
before "classrooms" and the words "or any other occupiable space(s)" shall be add
following "classrooms."
lxxxviii. In Section 915.2, Locations, "by Section 915.1.1" shall be deleted. Addit
in the third line, "915.2.3" shall be deleted and "915.2.4" shall be inserted.
lxxxix. A new subsection 915.2.4, Other occupancies, shall be added as follows:
"915.2.4 Other occupancies. Carbon monoxide detection equipment shall be in
other occupancies. Systems using detectors shall have a distinct visual and aud
notification at an approved location. When alarms are installed in lieu of detect
shall be located such that the audible signal is not less than 15 dB above the av
ambient sound level.
Exception: Carbon monoxide detection equipment shall not be required |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.17 Fire protection subcode
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
In (a)1i(5), added a second sentence.
Amended by R.2000 d.492, effective December 18, 2000.
See: 32 N.J.R. 3219(a), 32 N.J.R. 4437(b).
In (a)1ii, changed "1996" to "1999".
Amended by R.2001 d.196, effective June 18, 2001.
See: 33 N.J.R. 6(a), 33 N.J.R. 2090(a).
In (a)1, inserted reference to the fuel gas subcode in the introductory paragraph, rewrote iii and i
iv; in (b)1, inserted reference to the Fuel Gas Subcode.
Amended by R.2003 d.351, effective September 2, 2003.
See: 35 N.J.R. 1177(a), 35 N.J.R. 4051(a).
In (a), substituted "are" for "area" in the introductory paragraph and rewrote (i) and (ii) in 1.
Administrative Correction to (a)1iii and (a)1iv: Changed "Code/2000" to "Code/2003".
See: 37 N.J.R. 2860(a).
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
In (a)1i, substituted "2006" for "2000"; deleted (a)1i(5)(A) and (B); in (a)1ii, substituted "2005"
"2002"; and in (a)1iii and (a)1iv, substituted "2006" for "2003".
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
In the introductory paragraph of (a)1i, of (a)1iii and of (a)iv, substituted "2009" for "2006"; in (a
substituted "Fire and Smoke Protection Features" for "Fire Resistance-Rated Construction"; in (a)
substituted "2613" for "2607"; and in the introductory paragr |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
iv. Appendix AI, Private Sewage Disposal; Appendix AJ, Existing Buildings and
Structures; Appendix AL, Permit Fees; Appendix AM, Home Day Care--R-3 Occu
Appendix AN, Venting Methods; Appendix AO, Automatic Vehicular Gates; and
Appendix AP, Sizing of Water Piping Systems, shall be deleted.
v. Appendix AQ, Tiny Houses; Appendix AR, Light Straw-Clay Construction; an
Appendix AS, Strawbale Construction, shall be adopted as part of this subcode.
vi. Appendix AT, Solar-Ready Provisions--Detached One- And Two-Family Dwe
and Townhouses, shall be optional at the discretion of the permit applicant.
vii. Appendix AV, Board of Appeals, shall be deleted in its entirety.
viii. Appendix AW, 3D-Printed Building Construction, shall be adopted as part of
subcode. The Appendix shall be amended as follows:
(1) In Section AW103.2, Design approval, in the last line, "Section R104.11"
deleted, and "the administrative provisions of the Uniform Construction Code
(N.J.A.C. 5:23)" shall be inserted in its place.
History
HISTORY:
New Rule, R.1985 d.324, effective July 1, 1985.
See: 17 N.J.R. 861(c), 17 N.J.R. 1646(a).
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1988 d.388, effective August 1, 1988.
See: 20 N.J.R. 1130(a), 20 N.J.R. 2073(b).
Added (c). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
shall be inserted. In addition, under construction Type IIIB for Group R-2 S, "
be deleted and "4" shall be inserted. Finally, under construction Type IVB for
"12" shall be deleted and "10" shall be inserted.
(21) Under construction Type IB for Group R-3 S, "12" shall be deleted and "
be inserted. Under construction Type IIB for Group R-3 S, "5" shall be deleted
shall be inserted. Under construction Type IIIB for Group R-3 S, "5" shall be d
and "4" shall be inserted. In addition, under construction Type IVB for R-3 S,
shall be deleted and "5" shall be inserted. Finally, under construction Type VB
Group R-3 S and S13R, "4" shall be deleted and "3" shall be inserted.
(22) Under construction Type IB for Group R-4 S, "12" shall be deleted and "
be inserted. Under construction Type IIB for Group R-4 S, "5" shall be deleted
shall be inserted. In addition, under construction Type IIIB for Group R-4 S, "
be deleted and "4" shall be inserted. Finally, under construction Type IVB for
"12" shall be deleted and "5" shall be inserted.
(23) Under construction Type IB for Group S-1 NS, "11" shall be deleted and
be inserted and for Group S-1 S, "12" shall be deleted and "6" shall be inserted
construction Type IVB for S-1 S, "7" shall be deleted and "6" shall be inserted.
addition, under construction Type VA for Group S-1 NS, "3" shall be deleted a
shall be inserted and for Group S-1 S, "4" shall be deleted and "3" shall be inse
(24) Under cons |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.17 Fire protection subcode
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote (a).
Amended by R.2000 d.166, effective April 17, 2000.
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
In (a)1i(5), added a second sentence.
Amended by R.2000 d.492, effective December 18, 2000.
See: 32 N.J.R. 3219(a), 32 N.J.R. 4437(b).
In (a)1ii, changed "1996" to "1999".
Amended by R.2001 d.196, effective June 18, 2001.
See: 33 N.J.R. 6(a), 33 N.J.R. 2090(a).
In (a)1, inserted reference to the fuel gas subcode in the introductory paragraph, rewrote iii and i
iv; in (b)1, inserted reference to the Fuel Gas Subcode.
Amended by R.2003 d.351, effective September 2, 2003.
See: 35 N.J.R. 1177(a), 35 N.J.R. 4051(a).
In (a), substituted "are" for "area" in the introductory paragraph and rewrote (i) and (ii) in 1.
Administrative Correction to (a)1iii and (a)1iv: Changed "Code/2000" to "Code/2003".
See: 37 N.J.R. 2860(a).
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
In (a)1i, substituted "2006" for "2000"; deleted (a)1i(5)(A) and (B); in (a)1ii, substituted "2005"
"2002"; and in (a)1iii and (a)1iv, substituted "2006" for "2003".
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Rewrote (a)3.
Administrative correction.
See: 38 N.J.R. 926(a).
Administrative correction.
See: 38 N.J.R. 1827(b).
In (a)3, Note 1 of the table, inserted "in" following "not installed".
Amended by R.2007 d.310, effective October 1, 2007.
See: 39 N.J.R. 135(a), 39 N.J.R. 4113(b).
Added (a)9.
Amended by R.2008 d.112, effective May 5, 2008.
See: 39 N.J.R. 4366(a), 40 N.J.R. 2229(a).
In the table at (a)1, rewrote entries in "Ch. 4", "Ch. 16", "Ch. 30" and "Ch. 31", and in entries "C
and "Ch. 6", inserted "/Fire" in the third column; in the table at (a)2, deleted entry "Ch. 17" and a
entries "Ap. J", "Ap. K" and "Ap. L"; rewrote tables at (a)4, (a)5 and (a)6; and in the table at (a)7,
"Ch. 6", inserted entry "635" and rewrote entry "Ch.7".
Amended by R.2009 d.51, effective February 2, 2009.
See: 40 N.J.R. 5325(a), 41 N.J.R. 738(a).
In the table in (a)1, in the entry for "Ch. 9", inserted "909.12.1 and 910.4.4" in column "Section/
and, under the sub-headings "Plan Review" and "Inspection" under column "Responsibility", inse
"(except 909.12.1 and 910.4.4)" following "Fire" and inserted "Fire/Electric"; and in (c), updated
N.J.A.C. reference.
Amended by R.2011 d.269, effective November 7, 2011.
See: 43 N.J.R. 904(a), 43 N.J.R. 3008(a).
Rewrote the tables in (a)1 through (a)7. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
See: 14 N.J.R. 1326(a), 15 N.J.R. 141(c).
Added (a) 3 and (c).
Amended by R.1984 d.314, eff. August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b).
Section substantially amended.
Amended by R.1986 d.12, effective February 3, 1986.
See: 17 N.J.R. 2714(a), 18 N.J.R. 267(a).
(a)1i had a change of address; (a)3 and (c) added.
Amended by R.1987 d.81, effective February 2, 1987.
See: 18 N.J.R. 2237(b), 19 N.J.R. 289(d).
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1989 d.66, effective February 6, 1989.
See: 20 N.J.R. 2846(a), 21 N.J.R. 288(a).
Added (c).
Amended by R.1990 d.58, effective February 5, 1990.
See: 21 N.J.R. 3346(a), 22 N.J.R. 351(a).
Added (d) adopting the 1989 Supplement to the 1987 National Standard Plumbing Code.
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
Text added at (a)3; (d)3ii amended.
Amended by R.1990 d.507, effective October 15, 1990. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1983 d.12, eff. February 7, 1983, operative February 22, 1983.
See: 14 N.J.R. 132(a), 15 N.J.R. 141(c).
Added (a)2 and (c).
Amended by R.1984 d.314, eff. August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b).
This section was substantially amended.
Amended by R.1985 d.154, effective April 1, 1985 (operative July 1, 1985.)
See: 17 N.J.R. 239(a), 17 N.J.R. 810(a).
(a)2 added; subsection (c) added.
Correction: N.J.A.C. 5:23-3.14(c)5 was incorrect in adoption.
See: 17 N.J.R. 1409(a).
Amended by R.1985 d.324, effective July 1, 1985.
See: 17 N.J.R. 861(c), 17 N.J.R. 1646(a).
(b)3i: amended text.
Amended by R.1986 d.380, effective September 22, 1986.
See: 18 N.J.R. 1235(a), 18 N.J.R. 1931(a).
Substantially amended.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1988 d.270, effective June 20, 1988. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In the introductory paragraph of (b)9v, deleted "(Siamese)" following "department".
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Amended by R.2022 d.120, effective September 19, 2022.
See: 54 N.J.R. 699(a), 54 N.J.R. 1793(a).
Rewrote the section.
Administrative correction, effective October 25, 2023.
See: 55 N.J.R. 2322(b).
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
Rewrote (b)11ii and (b)11iii.
Amended by R.2026 d.086, effective August 17, 2026.
See: 57 N.J.R. 2354(a), 58 N.J.R. 1898(a).
Rewrote the section.
Annotations
Notes
Chapter Notes
Case Notes |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.21 One- and two-family dwelling subcode
xxv. New Section R310.7.5 shall be inserted as follows: "R310.7.5, Monitoring. T
system shall be monitored by an approved supervising station and shall be maintai
accordance with NFPA 72."
xxvi. At Section R311.2, Where required, "and R311.2.2" shall be deleted. Also,
R311.2.2, Alterations, repairs and additions, shall be deleted. Lastly, Exception 2 o
Section R311.6, Power source, shall be deleted.
xxvii. Section R313.1.2, Habitable attics and basements in existing buildings, shal
deleted in its entirety.
xxviii. Section R316, Habitable attics, shall be deleted.
xxix. At Section R318.3.1, Floor elevations at the required egress doors, in the Ex
"7 3/4 inches (196 mm)" shall be deleted and "8 1/4 inches (210 mm)" shall be ins
Also, at Section R318.3.2, Floor elevations at other exterior doors, "7 3/4 inches (1
mm)" shall be deleted and "8 1/4 inches (210 mm)" shall be inserted."
xxx. At Section R318.7.5.1, Risers, "7 3/4 inches (196 mm)" shall be deleted and
inches (210 mm)" shall be inserted.
xxxi. At Sections R318.7.5.2, Treads, and R318.7.5.2.1, Winder treads, "10 inche
mm)" shall be deleted and "9 inches (229 mm)" shall be inserted.
xxxii. Section R318.7.9, Stairways in existing buildings, shall be deleted in its ent
xxxiii. Section R318.7.10, Illumination, shall be deleted in its entirety.
xxxiv. At Section R319.1, Emergency escape and rescue opening required, "Base
habitable attics and" sha |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.22 Fuel gas subcode
Substituted "Code/2018" for "Code/2015" in the introductory paragraph of (a)1, in (a)1ii, and in
introductory paragraph of (b); substituted "appropriate" for "building" in (b)2iii.; and substituted
for "IPC-15" in (b)7i(1).
Amended by R.2021 d.004, effective January 4, 2021.
See: 52 N.J.R. 385(a), 53 N.J.R. 47(a).
In (b)4iii, substituted "402.7.1, Operation below -5[degrees]F (-21[degrees]C)" for "402.6.1, Liq
petroleum gas systems".
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
In the introductory paragraph of (b), inserted a comma following "sections"; and added (b)4iv.
Amended by R.2026 d.086, effective August 17, 2026.
See: 57 N.J.R. 2354(a), 58 N.J.R. 1898(a).
Rewrote the section.
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.8 Products violating the Code
i. Portable unvented natural gas, liquified petroleum gas and kerosene heaters whe
offered for sale for use in buildings for human occupancy, unless they are tested, li
labeled and certified by a nationally recognized testing laboratory such as the Ame
Gas Association Laboratories (AGA), Underwriters Laboratories. Inc. (UL) or Fac
Mutual (FM);
ii. Urea formaldehyde foam insulation, unless offered for sale for use elsewhere th
buildings.
History
HISTORY:
R.1983 d.296, effective August 1, 1983.
See: 15 N.J.R. 587(a), 15 N.J.R. 1247(a).
Amended by R.1985 d.38, effective February 19, 1985.
See: 16 N.J.R. 3074(a), 17 N.J.R. 421(a).
(d) added.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
(d)1i and ii: 904.2 was 1404.2; 904.3 was 1404.3.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1992 d.47, effective February 3, 1992.
See: 23 N.J.R. 3602(a), 24 N.J.R. 405(a).
Low volume water closet exception added at (d)4iii. |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.20A
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
August 17, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.20A (Reserved)
History
HISTORY:
New Rule R.1992 d.183, effective April 20, 1992.
See: 24 New Jersey Register 167(a), 24 New Jersey Register 1475(b).
Repealed by R.2001 d.196, effective June 18, 2001.
See: 33 New Jersey Register 6(a), 33 New Jersey Register 2090(a).
Section was "Indoor air quality subcode".
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Rewrote (b)21ii.
Administrative Correction.
See: 38 N.J.R. 3024(a).
Amended by R.2006 d.381, effective November 6, 2006.
See: 38 N.J.R. 35(a), 38 N.J.R. 4691(a).
In (b)15ii, added the last sentence; added new (b)15iv; and recodified former (b)15iv through (b
(b)15v through (b)15xvi.
Amended by R.2007 d.51, effective February 5, 2007.
See: 38 N.J.R. 375(a), 39 N.J.R. 371(a).
Added new (b)2viii; recodified former (b)2viii through (b)2x as (b)2ix through (b)2xi; added ne
recodified former (b)3iii through (b)3viii as (b)3iv through (b)3ix; added new (b)9i; recodified fo
(b)9i through (b)9xi as (b)9ii through (b)9xii; added new (b)9xiii; recodified former (b)9xii throu
(b)9xv as (b)9xiv through (b)9xvii; added new (b)10xxii and (b)10xxiii; and recodified former (b)
as (b)10xxiv.
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
Rewrote the section.
Administrative correction.
See: 39 N.J.R. 1249(a).
Amended by R.2007, d.384, effective December 17, 2007.
See: 39 N.J.R. 2684(a), 39 N.J.R. 5211(a).
Added new (b)3i and (b)3ii; and recodified former (b)3i through (b)3vii as (b)3iii through (b)3ix
Amended by R.2008 d.39, effective March 3, 2008.
See: 39 N.J.R. 2175(a), 40 N.J.R. 1084(a). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.7 Municipal approvals of alternative materials, equipment, or methods of construction
he may approve its use subject to the requirements of the regulations. The cost of all tests,
and investigations required under these provisions shall be paid by the applicant.
(c) Research reports: The appropriate subcode official may accept, as supporting data to a
this determination, duly authenticated research reports from approved authoritative source
materials or assemblies proposed for use which are not specifically provided for in the reg
History
HISTORY:
Amended by R.1992 d.390, effective October 5, 1992.
See: 24 New Jersey Register 1844(a), 24 New Jersey Register 3515(b).
Reference to exception in 3.8 added.
Amended by R.2003 d.384, effective October 6, 2003.
See: 35 New Jersey Register 2422(a), 35 New Jersey Register 4712(a).
Rewrote (a).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.19
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
June 15, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.19 (Reserved)
History
HISTORY:
Amended by R.1982 d.7, eff. February 1, 1982.
See: 13 N.J.R. 171(a), 14 N.J.R. 142(a).
This section was recodified from 5:23-3.9.
Repealed by R.2019 d.083, effective August 5, 2019.
See: 51 N.J.R. 3(a), 51 N.J.R. 1269(a).
Section was "Manufactured home subcode".
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.15 Plumbing subcode
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1991 d.326, effective July 1, 1991.
See: 23 N.J.R. 804(a), 23 N.J.R. 2044(a).
GPF set at 1.6; gravity water closets not permitted in commercial uses.
Amended by R.1991 d.571, effective November 18, 1991.
See: 23 N.J.R. 2619(a), 23 N.J.R. 3444(b).
Added new (c).
Amended by R.1992 d.67, effective February 3, 1992.
See: 23 N.J.R. 3602(a), 24 N.J.R. 404(b).
Low volume water closet exception added at (b)18i(1).
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.122, effective March 6, 1995 (operative July 1, 1995).
See: 26 N.J.R. 4874(a), 27 N.J.R. 894(a).
Amended by R.1998 d.136, effective March 16, 1998.
See: 30 N.J.R. 4(a), 30 N.J.R. 1038(a).
In (b)9, added xii.
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.2001 d.340, effective September 17, 2001.
See: 33 N.J.R. 1245(a), 33 N.J.R. 3308(b). |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.18 Energy subcode
(1) At Section RC101.2, Application, and Section RH102.1, Application, the e
shall be deleted.
History
HISTORY:
Amended by R.1987 d.387, effective October 5, 1987.
See: 19 N.J.R. 433(b), 19 N.J.R. 1793(a).
Substantially amended.
Amended by R.1988 d.50, effective February 1, 1988.
See: 19 N.J.R. 1862(b), 20 N.J.R. 268(a).
Added (b)6; renumbered (b)6.-7. as (b)7.-8.
Amended by R.1988 d.417, effective September 6, 1988.
See: 20 N.J.R. 699(b), 20 N.J.R. 2274(a).
Substantially amended.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1991 d.326, effective July 1, 1991.
See: 23 N.J.R. 804(a), 23 N.J.R. 2044(a).
Section E-502.1 deleted.
Amended by R.1991 d.429, effective August 19, 1991.
See: 23 N.J.R. 1487(a), 23 N.J.R. 2501(a).
In (b)5, deleted old and added new i. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
See: 21 N.J.R. 3696(a), 22 N.J.R. 1356(a).
Provisions for enforcement of radon subcode added at (g).
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1991 d.325, effective July 1, 1991.
See: 23 N.J.R. 805(a), 23 N.J.R. 2046(a).
Other elevator devices covered; enforcement responsibilities clarified.
Amended by R.1992 d.147, effective April 6, 1992.
See: 24 N.J.R. 170(a), 24 N.J.R. 1397(a).
Elevators wholly within R-2 residences exempt.
Amended by R.1992 d.183, effective April 20, 1992.
See: 24 N.J.R. 167(a), 24 N.J.R. 1475(b).
Enforcement of indoor air quality subcode assigned to building subcode official.
Amended by R.1993 d.187, effective May 3, 1993.
See: 25 N.J.R. 624(a), 25 N.J.R. 1875(a).
Added subsection (j); deleted "Allocation of enforcement" from heading.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.143, effective March 20, 1995 (operative July 1, 1995).
See: 26 N.J.R. 4872(a), 27 N.J.R. 1179(b).
Amended by R.1997 d.409, effective October 6, 1997.
See: 29 N.J.R. 2736(a), 29 N.J.R. 4281(a). |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.9
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
June 15, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.9 Interpretations and opinions
(a) Whenever the Commissioner shall, in accordance with applicable provisions of the
Administrative Procedure Act, make any rule constituting an interpretation of any provisi
regulations, such shall be binding provided, however, that such interpretations shall be pro
in nature. Such interpretations shall not alter the ruling of a subcode official already rende
specific instance relating to a specific permit or structure. Requests for interpretations shal
the form, and submitted in accordance with the procedure, set forth in N.J.A.C. 5:2-2.
(b) In response to a written inquiry or request setting forth a specific factual situation, or
own initiative, the Construction Code Element may issue a formal technical opinion to cla
provisions of the adopted subcodes. Such formal technical opinion shall be signed by the
Director of the Element and shall be binding upon the Element and upon other code enfor
agencies and licensed officials. Formal technical opinions shall be prospective in nature, s
based upon adopted subcodes or upon authoritative test results or standards incorporated b
reference into an adopted subcode and shall not alter the ruling of a licensed official alrea
rende |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Cha
pter
Section/Title
Responsibility
Plan Review
Inspection
G2425.1-G2425.2
Building/Fire
Fire
G2425.3
Building/Fire
Building
G2425.4-G2425.6
Building/Fire
Fire
G2425.7
Building/Fire
Building
G2425.8-G2425.10
Building/Fire
Fire
G2425.11
Building/Fire
Building
G2425.12-
G2425.15.1
Building/Fire
Fire
G2425.15.2
Fire
Fire
G2425.15.3
Building/Fire
Building
G2425.15.4-
G2427.5.1
Building/Fire
Fire
G2427.5.2
Building/Fire
Building
G2427.5.3-
G2427.5.6.4
Building/Fire
Fire
G2427.5.7-
G2427.5.9
Building
Building
G2427.5.10
Building/Fire
Fire
G2427.6-G2427.8
Building/Fire
Fire
G2427.9
Plumbing
Plumbing
G2427.10.1-
G2430.1
Building/Fire
Fire
G2430.2
Building/Fire
Building
G2432-G2434
Plumbing/Fire
Plumbing
G2435
Plumbing/Fire
Fire
G2436-G2440.3
Building/Fire
Building
G2440.4-2440.5
Building/Fire
Fire
G2440.6-2440.7
Building/Fire
Building
G2441
Plumbing
Plumbing
G2442
Building/Fire
Building
G2443
Plumbing
Plumbing
G2444-G2446
Building/Fire
Building
G2447
Fire
Fire
G2448-G2449.3
Plumbing
Plumbing
G2449.4-2450.3
Building/Fire
Building |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.9 Interpretations and opinions
(d) In response to a written or oral inquiry or request setting forth a specific factual situati
staff member of the Construction Code Element may issue an informal opinion as to the p
application of the regulations if the issue is one with which he has authority to deal. Such
opinion shall only be in writing if it is issued in response to a written inquiry or request an
not be binding upon the Element or any other party.
History
HISTORY:
Amended by R.1981 d.454, effective December 7, 1981.
See: 13 New Jersey Register 561(a), 13 New Jersey Register 886(a).
Section substantially amended.
Administrative Correction: Name change.
See: 22 New Jersey Register 2503(b).
Amended by R.1995 d.340, effective June 19, 1995.
See: 27 New Jersey Register 1512(a), 27 New Jersey Register 2388(a).
Redesignated (c) as (d) and added a new (c).
Administrative correction.
See: 31 New Jersey Register 4259(a).
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.6 Standards; accepted practice
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Added (b)1.
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.22 Fuel gas subcode
See: 36 N.J.R. 3329(b), 37 N.J.R. 267(a).
Rewrote the section.
Administrative correction.
See: 37 N.J.R. 885(a).
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
Rewrote the section.
Administrative correction.
See: 40 N.J.R. 1829(a).
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote the section.
Amended by R.2011 d.269, effective November 7, 2011.
See: 43 N.J.R. 904(a), 43 N.J.R. 3008(a).
Added (b)4v.
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In (b)6i, substituted "614.10" for "614.8".
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11 Enforcement activities reserved to the Department
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
xx. In Section 1010.3.4, Security grilles, "In Groups B, F, M, and S" shall be delet
"horizontal" shall be capitalized.
xxi. In Section 1011.5.2, Riser height and tread depth, Exception 3, change the ma
riser height from "7 3/4 inches (197 mm)" to "8 1/4 inches (210 mm),", change the
minimum tread depth from "10 inches (254 mm)" to "9 inches (229 mm)," and cha
minimum winder tread depth at the walk line from "10 inches (254 mm)" to "9 inc
mm)." In the same section, Exception 4 shall be deleted.
xxii. In Section 1013.5, Internally illuminated exit signs, "Chapter 27" shall be del
"the electrical subcode (N.J.A.C. 5:23-3.16)" shall be inserted.
xxiii. In Section 1014.2, Height, insert new Exception 1 as follows: "1. For occup
Group R-3, and within individual dwelling units in occupancies of Group R-2, han
shall have a minimum height of 30 inches and a maximum height of 38 inches me
vertically from the nosing of the treads." In the same section, Exceptions 1 through
be renumbered as 2 through 4.
xxiv. In Section 1014.4, Continuity, Exception 4 shall be deleted.
xxv. In Section 1015.3, Height, in Exception 1 "not more than three stories above
height" in the first and second line shall be deleted and "not more than three storie
grade in height with separate means of egress" in the third through fifth line shall b
deleted. Additionally, in Exception 3, "34 inches (864mm)" shall be deleted and "3
(762 mm)" shall be inserted.
xxvi |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.20 Mechanical subcode
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Enforcement of indoor air quality subcode assigned to building subcode official.
Amended by R.1993 d.187, effective May 3, 1993.
See: 25 N.J.R. 624(a), 25 N.J.R. 1875(a).
Added subsection (j); deleted "Allocation of enforcement" from heading.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.143, effective March 20, 1995 (operative July 1, 1995).
See: 26 N.J.R. 4872(a), 27 N.J.R. 1179(b).
Amended by R.1997 d.409, effective October 6, 1997.
See: 29 N.J.R. 2736(a), 29 N.J.R. 4281(a).
In (g), deleted reference to exception to exclusive authority provided in N.J.A.C. 5:23-3.11(h).
Amended by R.1997 d.418, effective October 6, 1997.
See: 29 N.J.R. 3402(a), 29 N.J.R. 4286(a).
In (f), inserted reference to (j); and added (j)1.
Amended by R.1998 d.28, effective January 5, 1998.
See: 29 N.J.R. 3603(a), 30 N.J.R. 129(a).
Inserted (k) stating responsibility for the enforcement of the rehabilitation subcode.
Repeal and New Rule, R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Section was "Responsibility".
Amended by R.1999 d.259, effective August 16, 1999.
See: 31 N.J.R. 825(a), 31 N.J.R. 2330(a).
In (d)1 and (d)2, under "MECHANICAL SUBCODE", added references to N.J.A.C. 5:23-3.20( |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.17 Fire protection subcode
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1984 d.314, effective August 6, 1984.
See: 16 N.J.R. 1139(a), 16 N.J.R. 2084(b).
Section substantially amended.
Amended by R.1986 d.380, effective September 22, 1986.
See: 18 N.J.R. 1235(a), 18 N.J.R. 1931(a).
Substantially amended.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
Reference to 1989 Supplement added; (a)1i(7) amended.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote (a).
Amended by R.2000 d.166, effective April 17, 2000. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
xvii. At Section 1704.4, Contractors' responsibility, in the first sentence, "main w
shall be deleted. In addition, in the same sentence, "or a wind-" shall be deleted.
Additionally, in the first sentence, "building official" shall be deleted and "constru
official" shall be inserted.
xviii. At Section 1704.5, Submittals to the building official, in the title and in the
sentence, "building official" shall be deleted and "construction official" shall be in
addition, in item 7, "B, C," shall be deleted in reference to seismic design categori
xix. Section 1704.6, Structural observations, shall be deleted in its entirety.
xx. Section 1704.6.1 Structural observations for structures, shall be deleted in its
xxi. In Section 1705.2, Steel construction, "the on-site erection of" shall be insert
between "of" and "steel."
xxii. In Table 1705.3, Required special inspections and test of concrete constructi
Item #11, "C," shall be deleted from the Design Category listing. Additionally, in
"building official" shall be deleted and "construction official" shall be inserted.
xxiii. At Section 1705.4, Masonry construction, "in Seismic Design Category D,
shall be inserted after the word "construction."
xxiv. At Section 1705.5, Wood construction, Section 1705.5.1, High-load diaphra
and Section 1705.5.2, Metal-plate-connected wood trusses spanning 60 feet or gre
shall be deleted. Additionally, Section 1705.5.3, Mass timber construction shall r |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
R406.2.1 Floors. Dampproofing materials for floors shall be installed between
floor and the base course required by Section R406.4.1, except where a separat
provided above a concrete slab.
Where installed beneath the slab, dampproofing shall consist of not less th
(0.006 inch; 0.152 mm) polyethylene with joints lapped not less than 6 inc
mm), or other approved methods or materials. Where permitted to be installed
the slab, dampproofing shall consist of mopped-on bitumen, not less than 4-m
inch; 0.102 mm) polyethylene, or other approved methods or materials. Joi
membrane shall be lapped and sealed in accordance with the manufacturer's in
instructions.
R406.2.2 Walls. Dampproofing materials for walls shall be installed on the ex
surface of the wall, and shall extend from the top of the footing to above groun
Dampproofing shall consist of a bituminous material, 3 pounds per squ
(16N/m) of acrylic modified cement, 1/8-inch (3.2 mm) coat of surface-bondin
complying with ASTM C 887, any of the materials permitted for waterpro
Section R406.3.2, or other approved methods or materials.
R406.2.2.1 Surface preparation of walls. Prior to application of dampproofing
materials on concrete walls, holes and recesses resulting from the removal of f
shall be sealed with a bituminous material or other approved methods or mater
masonry walls shall be parged on the exterior surface below ground level with
than 3/8 inch (9.5 mm) |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.20 Mechanical subcode
Rewrote the section.
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Substituted "Code/2018" for "Code/2015" in the introductory paragraph of (a)1, in (a)1ii, and in
introductory paragraph of (b); and substituted "appropriate" for "building" in (b)2iii.
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Substituted "Code/2021" for "Code/2018" throughout; in (a)1 substituted "at"for "in"; and rewro
Administrative correction, effective June 20, 2023.
See: 55 N.J.R. 1385(a).
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a).
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
In (b)4ii, substituted "at" for the first occurrence of "in" and " "and." " for " "and"."
Amended by R.2026 d.086, effective August 17, 2026.
See: 57 N.J.R. 2354(a), 58 N.J.R. 1898(a).
Rewrote the section.
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11B Underground storage tank systems
In (d)3, deleted "with a capacity of 2000 gallons or less" following "Tanks".
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.2 Matters covered; exceptions
HISTORY:
Amended by R.1981 d.132, effective May 7, 1981.
See: 13 N.J.R. 121(a), 13 N.J.R. 258(d).
Amended by R.1986 d.448, effective November 3, 1986.
See: 18 N.J.R. 757(a), 18 N.J.R. 2194(a).
Deleted (b)1 and 4; recodified (b)2 and 3 to (b)1 and 2.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
(b)1: model subcode revisions.
Amended by R.1988 d.144, effective April 4, 1988.
See: 19 N.J.R. 1778(a), 20 N.J.R. 783(a).
Changed (b)2 to (c) and (d).
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.603, effective November 20, 1995 (operative March 20, 1996).
See: 27 N.J.R. 2655(a), 27 N.J.R. 4699(a).
Amended by R.1997 d.269, effective July 7, 1997.
See: 29 N.J.R. 968(a), 29 N.J.R. 2817(a).
Inserted (d)5i; in (d)6vi, amended N.J.A.C. reference; in (d)8, inserted reference to construction
inserted ", except as follows:"; deleted (d)8i; recodified former (d)8i(1) through (3) as (d)8i throu
inserted new (d)9iv; recodified former (d)9iv through vi as (d)9v through vii; and recodified form
(d)10.
Amended by R.1997 d.417, effective October 6, 1997. |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.6 Standards; accepted practice
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Added (b)1.
Annotations
Notes
Chapter Notes
Case Notes
Contractor not liable for injuries caused by failure of subcontractor to provide and install m
conformance with State building code. Miltz v. Borroughs--Shelving, a Div. of Lear Siegler,
N.J.Super. 451, 497 A.2d 516 (App.Div.1985).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Added new (b)9xlvi, (b)10xxx and (b)10xxxi; recodified former (b)9xlvi through (b)9liii as (b)9
through (b)9liv; and recodified former (b)10xxx through (b)10xxxviii as (b)10xxxii through (b)10
Amended by R.2013 d.081, effective June 3, 2013.
See: 44 N.J.R. 1303(a), 45 N.J.R. 1393(a).
In (b)17i, substituted "1" for "I".
Administrative correction.
See: 46 N.J.R. 74(b).
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Amended by R.2017 d.107, effective June 5, 2017.
See: 48 N.J.R. 1851(a), 49 N.J.R. 1381(b).
Added (b)8lxxvi through (b)8lxxx.
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In (b)10ii9, substituted "804.5" for "804.6" five times; in (b)10ii12, substituted "Location" for
"Accessible route"; in (b)10vi, deleted the period following "1104.4.1.2", and in 1104.4.2.2, subst
"a" for "the" and inserted ", of less than 3,000 square feet,"; added (b)10vii and (b)10xix, and rec
existing paragraphs to accommodate these insertions.
Amended by R.2018 d.060, effective January 16, 2018.
See: 49 N.J.R. 1276(a), 50 N.J.R. 310(a).
In the introductory paragraph of (b), substituted "shall be" for "are"; and in (b)3xvii, in the third
undesignated paragraph, substituted "five" for "5", in the fourth undesignated paragraph, deleted
quote preceding the semicolon, and added |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.20 Mechanical subcode
See: 23 N.J.R. 1487(a), 23 N.J.R. 2501(a).
In (a), added 3. Added new (c).
Amended by R.1992 d.183, effective April 20, 1992.
See: 24 N.J.R. 167(a), 24 N.J.R. 1475(b).
Text added at (b)7 and (c)1, deleting parts of article 16 of the mechanical subcode.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1995 d.120, effective March 6, 1995 (operative July 1, 1995).
See: 26 N.J.R. 4874(b), 27 N.J.R. 894(b).
Amended by R.1999 d.259, effective August 16, 1999.
See: 31 N.J.R. 825(a), 31 N.J.R. 2330(a).
Added (c).
Amended by R.2001 d.196, effective June 18, 2001.
See: 33 N.J.R. 6(a), 33 N.J.R. 2090(a).
Rewrote (a) and (b).
Administrative correction.
See: 33 N.J.R. 3310(a).
Amended by R.2002 d.15, effective January 22, 2002.
See: 33 N.J.R. 2933(b), 33 N.J.R. 3883(a), 34 N.J.R. 521(a).
In (c), added the last sentence in the introductory paragraph, and rewrote 1.
Amended by R.2003 d.137, effective April 7, 2003.
See: 34 N.J.R. 4277(a), 35 N.J.R. 1558(c). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
Amended by R.2013 d.081, effective June 3, 2013.
See: 44 N.J.R. 1303(a), 45 N.J.R. 1393(a).
In the table in (a)6, for the "Appx G" entry, substituted "105.1-105.4" for "105" and inserted "10
under the "Section/Title" heading, and under the sub-headings "Plan Review" and "Inspection" un
column "Responsibility", inserted "Electrical".
Amended by R.2015 d.029, effective February 17, 2015.
See: 46 N.J.R. 1507(a), 47 N.J.R. 459(a).
In the introductory paragraph of (d), inserted ", or stand-by power generators"; and rewrote (d)1.
Amended by R.2016 d.031, effective April 4, 2016.
See: 47 N.J.R. 2323(a), 48 N.J.R. 581(a).
Rewrote the section.
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In (a)2 table row 10.5.9, updated the "Inspection Responsibility"; in (a)4, International Energy
Conservation Code table, deleted the row for "R403.2"; in (a)6 table, deleted the row for "N1103.
rewrote (d).
Amended by R.2018 d.153, effective August 20, 2018.
See: 49 N.J.R. 2332(a), 50 N.J.R. 1888(a).
In the table in (a)1, rewrote entries in "Ch. 7" and "Ch. 31"; and in the table in (a)6, rewrote entr
"R302" and "R326".
Amended by R.2020 d.119, effective November 2, 2020.
See: 52 N.J.R. 371(a), 52 N.J.R. 1999(a).
Rewrote the tables in (a)1, (a)2, and (a)4 through (a)7.
Administrative correction, effective February 23, 2 |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
See: 52 N.J.R. 385(a), 53 N.J.R. 47(a).
In (c)3ii1, substituted "19-1" for "94-8"; in (c)3ii2, substituted "19-1"for "03-4"; in (c)3ii8, subst
"2'6" " for "2'8" "; deleted (c)3xxiii and recodified (c)3xxiv through (c)3xxv as (c)3xxiii through (
added (c)3xxv; in (c)3xliv3, deleted 3.9 and recodified 3.10 and 3.11 as 3.9 and 3.10; in (c)4v, su
"R404.2.5" for "404.2.5"; in (c)4vii, substituted "R404.4" for "404.4"; and in (c)12iv, substituted
"M1307.5" for "1307.5".
Amended by R.2022 d.022, effective February 7, 2022.
See: 53 N.J.R. 1133(a), 54 N.J.R. 263(a).
Recodified the former second occurrence of (c)3xix as (c)3xxxix.
Administrative change, effective July 6, 2022.
See: 54 N.J.R. 1551(a).
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Administrative correction, effective October 25, 2023.
See: 55 N.J.R. 2322(b).
Administrative correction, effective December 6, 2023.
See: 56 N.J.R. 35(b).
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a).
Petition for Rulemaking.
See: 57 N.J.R. 1448(b), 1619(c).
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11A Public school facility plan review and inspections; Uniform Construction Code enhancements in p
school facilities
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.5
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
August 17, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.5 Posting structures
(a) Posted use and occupancy: Every building and structure and part thereof designed for
business, factory and industrial, high hazard, mercantile, or storage use, (use groups B, F,
and S) as defined in chapter 3 of the building subcode shall be posted on all floors by the
with a suitably designed placard in a form designated by the building subcode official, wh
be securely fastened to the structure in a readily visible place, stating the use group and th
load and occupancy load.
(b) Posted occupancy load: Every building and structure and part thereof designed for use
place of public assembly or as an institutional building for harboring people for penal,
correctional, educational, medical or other care or treatment (use groups A, E and I) shall
posted with an approved placard designating the maximum occupancy load.
(c) Replacement of posted signs: All posting signs shall be furnished by the owner and sh
permanent design; they shall not be removed, or defaced and, if lost, removed or defaced,
immediately replaced.
(d) Posted hydraulic system data plate: In lieu of the nameplate of the referenced NFPA
standard(s), fire sprinkler system contractors are required to identify |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Amended by R.1986 d.380, effective September 22, 1986.
See: 18 N.J.R. 1235(a), 18 N.J.R. 1931(a).
Substantially amended.
Amended by R.1987 d.374, effective September 21, 1987.
See: 19 N.J.R. 1024(a), 19 N.J.R. 1720(b).
Model subcode revisions.
Amended by R.1988 d.270, effective June 20, 1988.
See: 20 N.J.R. 575(a), 20 N.J.R. 1344(a).
Added (a)3 and (c).
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
Text added at (c)2ii, 4, 5 and 7.
Amended by R.1990 d.325, effective July 2, 1990.
See: 21 N.J.R. 1654(a), 22 N.J.R. 2001(a).
Text added at (b)5xii(1) to conform to Fire Code.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1990 d.558, effective November 19, 1990.
See: 22 N.J.R. 1969(b), 22 N.J.R. 3483(a).
Conditional exemption for hoophouses or polyhouses added.
Amended by R.1991 d.325, effective July 1, 1991.
See: 23 N.J.R. 805(a), 23 N.J.R. 2046(a). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.16 Electrical subcode
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Amended by R.2023 d.138, effective December 4, 2023.
See: 55 N.J.R. 1056(a), 55 N.J.R. 2403(a).
Rewrote (a)2; in the introductory paragraph of (b), inserted a comma; in (b)7, inserted a comma
following "amended"; added new (b)7vi and recodified former (b)7vi to (b)7vii.
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
In (a)1, inserted "and 19".
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.10
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
August 17, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.10 (Reserved)
History
HISTORY:
Amended by R.1987 d.509, effective December 7, 1987.
See: 19 New Jersey Register 1264(a), 19 New Jersey Register 2270(a).
Substantially amended.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 New Jersey Register 2208(a), 22 New Jersey Register 3214(a).
Text conformed to BOCA National Code/1990.
Recodified to 5:23-4.3A by R.1992 d.272, effective July 6, 1992.
See: 24 New Jersey Register 1446(a), 24 New Jersey Register 2424(a).
Section was "Enforcing agency classification".
Annotations
Notes
Chapter Notes
NEW JERSEY ADMINISTRATIVE CODE |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.20 Mechanical subcode
In (c), deleted ", or any dwelling unit of Use Group" following "R-2", and substituted ", R-3 or
"R-3 located in a building required to be registered as a multiple dwelling" in the introductory par
Amended by R.2004 d.67, effective February 17, 2004.
See: 35 N.J.R. 4627(a), 36 N.J.R. 949(b).
In (c), added R-5 to the list of groups.
Amended by R.2005 d.35, effective January 18, 2005.
See: 36 N.J.R. 3329(b), 37 N.J.R. 267(a).
Rewrote the section.
Administrative correction.
See: 37 N.J.R. 885(a).
Amended by R.2006 d.75, effective February 21, 2006.
See: 37 N.J.R. 3110(a), 38 N.J.R. 1183(a).
Added (b)3iii; recodified former (b)3iii-ix as (b)3iv-x.
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
Rewrote the section.
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote (a) and (b).
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Amended by R.2019 d.095, effective September 3, 2019. |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.20 Mechanical subcode
Amended by R.2003 d.137, effective April 7, 2003.
See: 34 N.J.R. 4277(a), 35 N.J.R. 1558(c).
In (c), deleted ", or any dwelling unit of Use Group" following "R-2", and substituted ", R-3 or
"R-3 located in a building required to be registered as a multiple dwelling" in the introductory par
Amended by R.2004 d.67, effective February 17, 2004.
See: 35 N.J.R. 4627(a), 36 N.J.R. 949(b).
In (c), added R-5 to the list of groups.
Amended by R.2005 d.35, effective January 18, 2005.
See: 36 N.J.R. 3329(b), 37 N.J.R. 267(a).
Rewrote the section.
Administrative correction.
See: 37 N.J.R. 885(a).
Amended by R.2006 d.75, effective February 21, 2006.
See: 37 N.J.R. 3110(a), 38 N.J.R. 1183(a).
Added (b)3iii; recodified former (b)3iii-ix as (b)3iv-x.
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
Rewrote the section.
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote (a) and (b).
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.22 Fuel gas subcode
Rewrote the section.
Amended by R.2011 d.269, effective November 7, 2011.
See: 43 N.J.R. 904(a), 43 N.J.R. 3008(a).
Added (b)4v.
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Amended by R.2018 d.021, effective January 16, 2018.
See: 49 N.J.R. 306(a), 50 N.J.R. 303(a).
In (b)6i, substituted "614.10" for "614.8".
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Substituted "Code/2018" for "Code/2015" in the introductory paragraph of (a)1, in (a)1ii, and in
introductory paragraph of (b); substituted "appropriate" for "building" in (b)2iii.; and substituted
for "IPC-15" in (b)7i(1).
Amended by R.2021 d.004, effective January 4, 2021.
See: 52 N.J.R. 385(a), 53 N.J.R. 47(a).
In (b)4iii, substituted "402.7.1, Operation below -5[degrees]F (-21[degrees]C)" for "402.6.1, Liq
petroleum gas systems".
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Rewrote the section.
Amended by R.2025 d.093, effective August 18, 2025. |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.20 Mechanical subcode
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Substituted "Code/2018" for "Code/2015" in the introductory paragraph of (a)1, in (a)1ii, and in
introductory paragraph of (b); and substituted "appropriate" for "building" in (b)2iii.
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Substituted "Code/2021" for "Code/2018" throughout; in (a)1 substituted "at"for "in"; and rewro
Administrative correction, effective June 20, 2023.
See: 55 N.J.R. 1385(a).
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a).
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
In (b)4ii, substituted "at" for the first occurrence of "in" and " "and." " for " "and"."
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.18 Energy subcode
Rewrote the section.
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Administrative correction, effective March 25, 2021.
See: 53 N.J.R. 619(b).
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Section was "Energy Subcode"; rewrote the section.
Amended by R.2022 d.142, effective November 21, 2022.
See: 54 N.J.R. 759(a), 54 N.J.R. 2143(a).
Rewrote (b)7ii.
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
References to 1989 Supplement added; (b)1ii(5), 2, 4, 8 and 9 amended; (b)5, 6 and 7 added; (c)
Table R-201.2 added.
Amended by R.1991 d.571, effective November 18, 1991.
See: 23 N.J.R. 2619(a), 23 N.J.R. 3444(b).
Added new (c).
Amended by R.1992 d.208, effective May 18, 1992.
See: 24 N.J.R. 680(a), 24 N.J.R. 1879(a).
Code provisions applicable to flood hazard zones clarified.
Amended by R.1993 d.662, effective December 20, 1993.
See: 25 N.J.R. 3891(a), 25 N.J.R. 5918(a).
Amended by R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Rewrote the section.
Amended by R.2000 d.166, effective April 17, 2000.
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
In (c)4, substituted "more pressure than would be exerted by backfill" for "lateral pressure from
following "subject to" in ii, and substituted "drainage" for "designated disposal" preceding "syste
added "according to the Unified Soil Classification System, Group I Soils" at the end of iii; and in
(c)9iv.
Amended by R.2001 d.369, effective October 15, 2001.
See: 33 N.J.R. 2365(a), 33 N.J.R. 3674(a).
In (b), inserted "that are" following "type 5B construction", "no more" preceding "than 4,800 sq
feet", and substituted "seven feet" for "7 1/3 feet (2,235 mm.)".
Amended by R.2003 d.187, effective May 5, 2003. |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.17 Fire protection subcode
(10) Chapter 17--Special Inspections and Tests;
(11) Sections 2111 through 2113 of Chapter 21--Masonry;
(12) Sections 2603 through 2613 of Chapter 26--Plastic;
(13) Chapter 27--Electrical;
(14) Chapter 30--Elevators and Conveying Systems;
(15) Section 3104 of Chapter 31--Special Construction;
(16) Section 3309, 3311 and 3312 of Chapter 33--Safeguards During Construc
ii. National Electrical Code of the National Fire Protection Association adopted as
amended at N.J.A.C. 5:23-3.16 as the electrical subcode:
(1) Section 300.21 of Chapter 3--Wiring Methods and Materials;
(2) Article 450, Part III--Transformer Vaults of Chapter 4--Equipment for Gen
Use;
(3) Chapter 5--Special Occupancies;
(4) Article 695--Fire Pumps of Chapter 6--Special Equipment;
(5) Article 760--Fire Alarm Systems of Chapter 7--Special Conditions;
iii. International Mechanical Code of the International Code Council, Inc. adopted
amended at N.J.A.C. 5:23-3.20 as the mechanical subcode:
(1) Chapter 3--General Regulations;
(2) Chapter 5--Exhaust Systems;
(3) Chapter 6--Duct Systems;
(4) Chapter 7--Combustion Air;
(5) Chapter 8--Chimneys and Vents;
(6) Chapter 9--Specific Appliances, Fireplaces and Solid Fuel Burning Equip |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
See: 54 N.J.R. 1763(a), 55 N.J.R. 1999(a).
In (b), inserted a comma following "modified"; in (b)10, added new xiv, and recodified exsisting
through lviii as xv through lix.
Administrative correction, effective October 25, 2023.
See: 55 N.J.R. 2322(b).
Amended by R.2023 d.138, effective December 4, 2023.
See: 55 N.J.R. 1056(a), 55 N.J.R. 2403(a).
Rewrote the section.
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a).
Amended by R.2025 d.093, effective August 18, 2025.
See: 56 N.J.R. 1837(a), 57 N.J.R. 1817(a).
Added (b)3vi, in (b)5ii(2), (b)5iii(6), (b)5iii(16), and (b)5iv(2), deleted a comma following "IV"
(b)9xxxiii; in (b)19iv1, substituted "adopted by the administrative authority" for "applicability"; a
(b)16xxiii, inserted "D, E or F" ".
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
(12) Under construction Type IA for Group H-3 S, "UL" shall be deleted and
be inserted. In addition, under construction Type IIIA for Group H-3 S, "4" sha
deleted and "3" shall be inserted.
(13) Under construction Type IA for Group H-4 S, "UL" shall be deleted and
be inserted. In addition, under construction Type IIIA for Group H-4 S, "6" sha
deleted and "5" shall be inserted.
(14) Under Occupancy Classifications I-1, Condition 1, I-1, Condition 2, I-2,
the row that begins with NS shall be deleted.
(15) Under construction Type VA for Group I-3 S, "3" shall be deleted and "2
be inserted. In addition, under construction type VB for Group I-3 S, "2" shall
deleted and "NP" shall be inserted.
(16) Under OCCUPANCY CLASSIFICATION, add superscript "i" to Group
addition, the following note shall be added to the table: "i. Child care facilities
IIB, III, IV HT, or V construction shall be limited to 1 story."
(17) Under construction Type IB for Group M NS, "11" shall be deleted and "
be inserted and for Group M S, "12" shall be deleted and "7" shall be inserted.
construction Type IIIA for Group M NS, "4" shall be deleted and "3" shall be i
and for Group M S, "5" shall be deleted and "4" shall be inserted. In addition,
construction Type IVB for M S, "8" shall be deleted and "7" shall be inserted.
under construction Type VA for Group M NS, "3" shall be deleted and "2" sha
inserted and for Group M S, "4" shall be deleted and "3" s |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
See: 34 N.J.R. 4248(a), 35 N.J.R. 1939(c).
Rewrote the section.
Amended by R.2003 d.420, effective November 3, 2003.
See: 34 N.J.R. 4248(a), 35 N.J.R. 5073(a).
Rewrote (c).
Amended by R.2005 d.403, effective November 21, 2005.
See: 37 N.J.R. 2753(a), 37 N.J.R. 4399(b).
Rewrote (c).
Amended by R.2006 d.28, effective January 17, 2006.
See: 37 N.J.R. 2750(a), 38 N.J.R. 485(b).
Rewrote (c)15.
Administrative correction.
See: 38 N.J.R. 926(a).
Amended by R.2006 d.75, effective February 21, 2006.
See: 37 N.J.R. 3110(a), 38 N.J.R. 1183(a).
Added (c)10; recodified former (c)10-15 as (c)11-16.
Administrative correction.
See: 38 N.J.R. 1827(b).
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
Rewrote (a) and (c).
Amended by R.2007, d.384, effective December 17, 2007.
See: 39 N.J.R. 2684(a), 39 N.J.R. 5211(a). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11 Enforcement activities reserved to the Department
In j(4), deleted, "one- and two-family residential (building subcode Use Groups R-3 and R-5) or
preceding "vapor delivery".
Amended by R.2005 d.446, effective December 19, 2005.
See: 37 N.J.R. 2747(a), 37 N.J.R. 4907(a).
In (a), added ", plans and equipment" to the introductory paragraph and added (a)11.
Administrative correction.
See: 38 N.J.R. 3024(a).
Administrative correction.
See: 39 N.J.R. 4571(a).
Amended by R.2010 d.291, effective December 20, 2010.
See: 42 N.J.R. 1943(a), 42 N.J.R. 3053(a).
In (a)10, deleted "and" from the end; in (a)11, substituted "; and" for a period at the end; and add
(a)12.
Amended by R.2012 d.179, effective November 5, 2012.
See: 44 N.J.R. 1679(a), 44 N.J.R. 2557(a).
Rewrote (j)1.
Amended by R.2013 d.081, effective June 3, 2013.
See: 44 N.J.R. 1303(a), 45 N.J.R. 1393(a).
In (a)4 and (a)7, substituted "Class 1" for "Class I" and "Class 2" for "Class II" throughout; and i
deleted "N.J.A.C. 5:23-" preceding "4.24(b)2".
Amended by R.2015 d.029, effective February 17, 2015.
See: 46 N.J.R. 1507(a), 47 N.J.R. 459(a).
In (a)8, inserted ", and residential health care facilities licensed pursuant to N.J.A.C. 5:27A". |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
See: 20 N.J.R. 575(a), 20 N.J.R. 1344(a).
Added (a)3 and (c).
Amended by R.1990 d.253, effective May 21, 1990.
See: 22 N.J.R. 909(b), 22 N.J.R. 1554(a).
Text added at (c)2ii, 4, 5 and 7.
Amended by R.1990 d.325, effective July 2, 1990.
See: 21 N.J.R. 1654(a), 22 N.J.R. 2001(a).
Text added at (b)5xii(1) to conform to Fire Code.
Amended by R.1990 d.507, effective October 15, 1990.
See: 22 N.J.R. 2208(a), 22 N.J.R. 3214(a).
Text conformed to BOCA National Code/1990.
Amended by R.1990 d.558, effective November 19, 1990.
See: 22 N.J.R. 1969(b), 22 N.J.R. 3483(a).
Conditional exemption for hoophouses or polyhouses added.
Amended by R.1991 d.325, effective July 1, 1991.
See: 23 N.J.R. 805(a), 23 N.J.R. 2046(a).
Article 26 amended at (b)14.
Amended by R.1991 d.429, effective August 19, 1991.
See: 23 N.J.R. 1487(a), 23 N.J.R. 2501(a).
In (a), added 3. Added (c).
Amended by R.1992 d.244, effective June 15, 1992.
See: 24 N.J.R. 1147(a), 24 N.J.R. 2243(a).
Text added at (b)10v through viii. |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.11A Public school facility plan review and inspections; Uniform Construction Code enhancements in p
school facilities
End of Document |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.18 Energy subcode
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote the section.
Amended by R.2011 d.269, effective November 7, 2011.
See: 43 N.J.R. 904(a), 43 N.J.R. 3008(a).
In (b)2i, deleted " 'ICC Electrical Code' and" following "codes,", " 'National Electrical Code' and
following "deleted and", and "respectively" following "inserted"; and rewrote (b)6i.
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b).
Rewrote the section.
Amended by R.2019 d.095, effective September 3, 2019.
See: 51 N.J.R. 285(a), 51 N.J.R. 1399(a).
Rewrote the section.
Administrative correction, effective March 25, 2021.
See: 53 N.J.R. 619(b).
Amended by R.2022 d.111, effective September 6, 2022.
See: 54 N.J.R. 677(a), 54 N.J.R. 1707(a).
Section was "Energy Subcode"; rewrote the section.
Amended by R.2022 d.142, effective November 21, 2022.
See: 54 N.J.R. 759(a), 54 N.J.R. 2143(a).
Rewrote (b)7ii.
Administrative correction, effective July 23, 2024.
See: 56 N.J.R. 1708(a). |
- |
pdf_text |
| full-text |
Page 43 of 57
§ 5:23-3.4 Responsibilities
Cha
pter
Section/Title
Responsibility
Inspection
Plan Review
P2904.8.1 #1
Fire
Fire
P2904.8.1 #2
Fire
Fire
P2904.8.1 #3
Fire
Fire
P2904.8.1 #4 -
Fire/Plumbing
Plumbing
#6
P2904.8.1 #7
Plumbing
Plumbing
and #8
P2904.8.2 #1
Fire
Fire
P2904.8.2 #2 -
Fire/Plumbing
Fire
#4
App
x
Patio Covers
Building
Building
AH
App
x
Sound
Building
Building
AK
Transmission
App
x
Tiny Homes
Building/Fire (except that
Building (except that
AQ
for AQ106, responsibility
for AQ106,
shall be as applicable)
responsibility shall be
as applicable)
App
x
Strawbale
Building
Building
AS
Construction
App
x
Solar-Ready
As applicable
As applicable |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
In (a), inserted "ELECTRICAL SUBCODE" in categories 1 and 2, and updated references to off
"ENERGY SUBCODE" category 1; in (c)1 and 2, updated "ELECTRICAL SUBCODE" chapter
references.
Amended by R.2003 d.240, effective June 16, 2003.
See: 34 N.J.R. 3045(a), 35 N.J.R. 2637(c).
In (c)2, added " N.J.A.C. 5:23-3.16(c) Automatic rain sensor device".
Amended by R.2003 d.418, effective November 3, 2003.
See: 35 N.J.R. 21(a), 35 N.J.R. 5064(a).
Rewrote the section.
Amended by R.2004 d.131, effective April 5, 2004.
See: 35 N.J.R. 5336(a), 36 N.J.R. 1755(a).
In (a), (b), and (c), inserted "CABO Model Energy Code" following "ENERGY SUBCODE" an
ASHRAE Standard 90.1 tables throughout.
Amended by R.2004 d.312, effective August 16, 2004.
See: 35 N.J.R. 4947(a), 36 N.J.R. 3894(d).
Rewrote the section.
Administrative correction.
See: 37 N.J.R. 269(a).
Amended by R.2005 d.364, effective November 7, 2005.
See: 37 N.J.R. 2112(a), 37 N.J.R. 4216(a).
Rewrote the section.
Amended by R.2005 d.446, effective December 19, 2005.
See: 37 N.J.R. 2747(a), 37 N.J.R. 4907(a). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
vi. Section G2412.2, Liquefied petroleum gas storage, shall be amended to add th
following: "Notwithstanding the provisions contained in NFPA 58, the installation
Gas containers on roofs of buildings shall be strictly prohibited."
vii. Section G2412.3, Modifications to existing system, shall be deleted in its entir
viii. Add new Section G2412.11 as follows:
"G2412.11
(401.9) Protection from vehicle impact. Gas meters, related regulators and
that are installed indoors or outdoors and are subject to vehicle impact shal
protected by barriers meeting the requirements of Section 312 of the Intern
Fire Code. For the purpose of applying this provision, "subject to vehicle i
shall mean located within three feet of any garage door opening, driveway
designated parking area and not separated by a building wall from the spac
a vehicle may be operated.
Exception: If verification of the installation of an excess flow valve is pro
the gas utility, vehicle impact barriers shall not be required."
ix. In Section G2413.7.1, Operation below -5⁰F (21⁰C), insert the following at the
beginning of the section: "The operating pressure for undiluted LP-gas systems sh
exceed 20 psig (140 kPa gauge)."
x. In Section G2425.15.2, Flue passageways, in the first sentence, "free of obstruc
and combustible deposits" shall be deleted and "inspected in accordance with the c
verification program as provided for in N.J.A.C. 5:23-2.20(d)" |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.21 One- and two-family dwelling subcode
control system as described in Section R406.1.3, walls and floors shall be wate
in accordance with this section.
R406.3.1 Floors. Floors required to be waterproofed shall be of concrete and d
and constructed to withstand the hydrostatic pressures to which the floors will
subjected.
Waterproofing shall be accomplished by placing a membrane of rubberized
butyl rubber, fully adhered/fully bonded HDPE or polyolefin composite me
not less than 6-mil (0.006 inch; 0.152 mm) polyvinyl chloride with joints la
less than 6 inches (152 mm) or other approved materials under the slab. Joi
membrane shall be lapped and sealed in accordance with the manufacturer's in
instructions.
R406.3.2 Walls. Walls required to be waterproofed shall be of concrete or ma
and shall be designed and constructed to withstand the hydrostatic pressures an
lateral loads to which the walls will be subjected.
Waterproofing shall be applied from the bottom of the wall to not less than
(305 mm) above the maximum elevation of the ground-water table. The rem
the wall shall be dampproofed in accordance with Section R406.2.2. Wate
shall consist of two-ply hot-mopped felts, not less than 6-mil (0.006 inch; 0.
polyvinyl chloride, 40-mil (0.040 inch; 1.02 mm) polymer-modified aspha
(0.006 inch; 0.152 mm) polyethylene or other approved methods or material
of bridging nonstructural cracks. Joints in the membrane shall be lapped and
accordance with the manuf |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
Administrative correction.
See: 36 N.J.R. 3525(c).
Amended by R.2004 d.423, effective November 15, 2004.
See: 36 N.J.R. 3004(a), 36 N.J.R. 5090(a).
In (b)5, added ii.
Amended by R.2005 d.4, effective January 3, 2005.
See: 36 N.J.R. 4049(a), 37 N.J.R. 47(a).
In (b)19, added new iv and recodified former iv and v as v and vi.
Administrative correction.
See: 37 N.J.R. 502(b), 674(a).
Amended by R.2005 d.403, effective November 21, 2005.
See: 37 N.J.R. 2753(a), 37 N.J.R. 4399(b).
Added (b)14xi and recodified former (b)14xi-xiii as (b)14xii-xiv; added (b)18 and recodified for
(b)18-25 as (b)19-26.
Amended by R.2005 d.446, effective December 19, 2005.
See: 37 N.J.R. 2747(a), 37 N.J.R. 4907(a).
In (b)3viii(3), substituted "one- and two-family" for "single-family"; in (b)3viii(5), "Group R-5
includes: ..."
Amended by R.2006 d.28, effective January 17, 2006.
See: 37 N.J.R. 2750(a), 38 N.J.R. 485(b).
Rewrote (b)9, 20 and 21.
Amended by R.2006 d.157, effective May 1, 2006.
See: 37 N.J.R. 3108(a), 38 N.J.R. 1824(a). |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.18 Energy subcode
See: 33 N.J.R. 1241(a), 33 N.J.R. 2471(a).
Rewrote the section.
Administrative change.
See: 33 N.J.R. 3310(a).
Administrative correction.
See: 35 N.J.R. 2494(b).
Amended by R.2007 d.65, effective February 20, 2007.
See: 38 N.J.R. 3348(a), 39 N.J.R. 633(a).
In (a)1, substituted "International Code Council, known as the International Energy Conservatio
(IECC/2006)" for "Council of American Building Officials, Inc., known as the Model Energy
Code/1995)"; in (a)1i, substituted "IECC/2006" for "CABO Model Energy Code/1995" and "Inter
Code Council" for "BOCA International"; and rewrote (b).
Amended by R.2009 d.48, effective February 2, 2009.
See: 40 N.J.R. 5319(a), 41 N.J.R. 733(b).
Added new (b)2i, recodified former (b)2i and (b)2ii as (b)2ii as (b)2iii; and added (b)6.
Amended by R.2010 d.195, effective September 7, 2010.
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote the section.
Amended by R.2011 d.269, effective November 7, 2011.
See: 43 N.J.R. 904(a), 43 N.J.R. 3008(a).
In (b)2i, deleted " 'ICC Electrical Code' and" following "codes,", " 'National Electrical Code' and
following "deleted and", and "respectively" following "inserted"; and rewrote (b)6i.
Amended by R.2015 d.139, effective September 21, 2015.
See: 47 N.J.R. 9(a), 47 N.J.R. 2352(b). |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
In (g), deleted reference to exception to exclusive authority provided in N.J.A.C. 5:23-3.11(h).
Amended by R.1997 d.418, effective October 6, 1997.
See: 29 N.J.R. 3402(a), 29 N.J.R. 4286(a).
In (f), inserted reference to (j); and added (j)1.
Amended by R.1998 d.28, effective January 5, 1998.
See: 29 N.J.R. 3603(a), 30 N.J.R. 129(a).
Inserted (k) stating responsibility for the enforcement of the rehabilitation subcode.
Repeal and New Rule, R.1998 d.332, effective July 6, 1998.
See: 30 N.J.R. 1377(a), 30 N.J.R. 2421(b).
Section was "Responsibility".
Amended by R.1999 d.259, effective August 16, 1999.
See: 31 N.J.R. 825(a), 31 N.J.R. 2330(a).
In (d)1 and (d)2, under "MECHANICAL SUBCODE", added references to N.J.A.C. 5:23-3.20(c
Amended by R.2000 d.166, effective April 17, 2000.
See: 31 N.J.R. 4151(a), 32 N.J.R. 1376(a).
In (b)2, changed Chapter 21 and Chapter 31 through 33 references in the Building Subcode, and
Chapter 12 reference in the Mechanical Subcode; and in (d)2, deleted a former Chapter 21 referen
Building Subcode, and changed Chapter 12 reference in the Mechanical Subcode.
Amended by R.2001 d.141, effective May 7, 2001.
See: 32 N.J.R. 3917(a), 33 N.J.R. 746(a), 33 N.J.R. 1399(d).
In (b)1 and (b)2, deleted "as follows: (All except M-801.2)" following "Chapter 8" in the Mecha
Code; in (d)1, deleted "Chapter 8 as follows: M-801.2" in the Mechanical Code; in (d)2, de |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.9 Interpretations and opinions
(d) In response to a written or oral inquiry or request setting forth a specific factual situati
staff member of the Construction Code Element may issue an informal opinion as to the p
application of the regulations if the issue is one with which he has authority to deal. Such
opinion shall only be in writing if it is issued in response to a written inquiry or request an
not be binding upon the Element or any other party.
History
HISTORY:
Amended by R.1981 d.454, effective December 7, 1981.
See: 13 New Jersey Register 561(a), 13 New Jersey Register 886(a).
Section substantially amended.
Administrative Correction: Name change.
See: 22 New Jersey Register 2503(b).
Amended by R.1995 d.340, effective June 19, 1995.
See: 27 New Jersey Register 1512(a), 27 New Jersey Register 2388(a).
Redesignated (c) as (d) and added a new (c).
Administrative correction.
See: 31 New Jersey Register 4259(a).
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
N.J.A.C. 5:23-3.20A
This file includes all Regulations adopted and published through the New Jersey Register, Vol. 5
June 15, 2026
NJ - New Jersey Administrative Code > TITLE 5. COMMUNITY AFFAIRS > CHAPTER 23. UNIF
CONSTRUCTION CODE > SUBCHAPTER 3. SUBCODES
§ 5:23-3.20A (Reserved)
History
HISTORY:
New Rule R.1992 d.183, effective April 20, 1992.
See: 24 New Jersey Register 167(a), 24 New Jersey Register 1475(b).
Repealed by R.2001 d.196, effective June 18, 2001.
See: 33 New Jersey Register 6(a), 33 New Jersey Register 2090(a).
Section was "Indoor air quality subcode".
NEW JERSEY ADMINISTRATIVE CODE
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
"FIRE CODE OFFICIAL. A person that is a Fire Official as defined in N.J.A.C.
xiv. The definition of "foster care facilities" shall be deleted.
xv. The definition of "historic building" shall be deleted.
xvi. At the definition of "incapable of self-preservation," the following sentence s
added: "The movement of all persons (occupants, residents and staff) to an exit in
than 13 minutes."
xvii. The definition of "jurisdiction" shall be deleted.
xviii. At the definition of "Limited verbal or physical assistance," the following se
shall be added: The movement of all persons (occupants, residents, and staff) to an
more than 3 minutes, but not more than 13 minutes.
xix. The definition of "lodging house" shall be deleted.
xx. In the definition of "merchandise pad," "as indicated in Section 105.2" shall b
xxi. A definition of "nightclub" shall be inserted as follows:
"NIGHTCLUB. All buildings and places of public assembly designed for use
halls, eating and/or drinking establishments, and similar occupancies, in w
established maximum permitted occupant load exceeds the number of seats pro
more than 30 percent or which affords less than 12 square feet net area per occu
purposes of determining the net area per occupant, only the actual public assembly
rooms shall be considered. For purposes of applying the requirements of this
nightclub shall include all rooms, lobbies and other spaces connected theret
common means of egress |
- |
pdf_text |
| full-text |
Pa
§ 5:23-3.10 (Reserved)
Copyright © 2026 by the New Jersey Office of Administrative Law
End of Document |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.14 Building subcode
(8) Under the Occupancy Classification I-4, in the second column, the referen
footnote d shall be deleted from the NS.
(9) Under Occupancy Classification R, the row that begins with NS shall be d
iii. Table 504.4, ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLA
shall be amended as follows:
(1) Footnotes c, d, e, f, and h shall be deleted.
(2) Under construction Type VA for Group A-1 NS, "2" shall be deleted and "
be inserted and for Group A-1 S, "3" shall be deleted and "2" shall be inserted.
(3) Under construction Type IB for Group A-2 NS, "11" shall be deleted and "
be inserted and for Group A-2 S, "12" shall be deleted and "4" shall be inserted
construction Types IIA and IIB for Group A-2 NS, "3" and "2" shall be deleted
and "1" shall be inserted, respectively, and for Group A-2 S, "4" and "3" shall
deleted and "3" and "2" shall be inserted, respectively. Under construction Typ
and IIIB for Group A-2 NS, "3" and "2" shall be deleted and "2" and "1" shall
inserted, respectively, and for Group A-2 S, "4" and "3" shall be deleted and "3
"2" shall be inserted, respectively. Under construction Type IVC for Group A-
shall be deleted and "2" shall be inserted. Under construction Types IVB and I
Group A-2 S, "12" and "6" shall be deleted and "4" and "3" shall be inserted,
respectively. In addition, under construction Type IV HT for Group A-2 NS, "
be deleted and "2" shall be inserted and for Group A-2 S, "4" shall be deleted a
shall be |
- |
pdf_text |
| full-text |
Pag
§ 5:23-3.14 Building subcode
facilities" shall be deleted; and the terms "Boarding houses" and "Residential healt
facilities" shall be inserted.
iv. At Section 308.3, Group I-2, "Assisted living facilities" shall be added to the li
"Foster care facilities" shall be deleted.
v. In Section 308.3.1.1, Condition 1, at the end of the sentence, "and foster care fa
shall be deleted.
vi. At Section 308.3.2, Five or fewer persons receiving medical care, in the third l
delete "903.3.1.3 of this code or Section P2904 of the International Residential Co
insert "903.3.1.1".
vii. Section 308.5.1, Classification as Group E, shall be deleted in its entirety.
viii. At Section 310.2, Residential Group R-1, in the second line "in nature" shall
deleted. Additionally, the list of occupancies shall be deleted in its entirety and the
following list inserted:
"Hotels
Motels
Vacation timeshare properties"
ix. At Section 310.3, Residential Group R-2, in the second line "in nature" shall b
deleted. Additionally, the following shall be deleted from the list of occupancies:
"Boarding houses (non-transient)," "Congregate living facilities (non-transient) wi
than 16 occupants," "Hotels (non-transient) with more than five guest rooms," "M
(non-transient) with more than five guest rooms," and "Vacation timeshare propert
following item shall be added to the list: "Rooming houses with more than 5 occup
x. At Section 310.4, Residential Group R-3, in the first line "in nature |
- |
pdf_text |
| full-text |
Page
§ 5:23-3.4 Responsibilities
the end of the Building Subcode, and deleted "Chapter 8 as follows: M-801.2" in the Mechanical
Subcode.
Amended by R.2001 d.196, effective June 18, 2001.
See: 33 N.J.R. 6(a), 33 N.J.R. 2090(a).
In (a)1, (a)2, (b)1, (b)2, (d)1 and (d)2, rewrote Mechanical Subcode and inserted Fuel Gas Subc
Amended by R.2001 d.244, effective July 16, 2001 (operative January 16, 2002).
See: 33 N.J.R. 1241(a), 33 N.J.R. 2471(a).
In "ENERGY SUBCODE" categories of (a) through (c), listed specific sections of Chapters 5 an
relating to building subcode official responsibility.
Administrative correction.
See: 33 N.J.R. 3308(a).
Amended by R.2002 d.6, effective January 7, 2002.
See: 33 N.J.R. 2570(a), 33 N.J.R. 3883(a), 34 N.J.R. 268(a).
In (a), inserted "ELECTRICAL SUBCODE" in categories 1 and 2, and updated references to off
"ENERGY SUBCODE" category 1; in (c)1 and 2, updated "ELECTRICAL SUBCODE" chapter
references.
Amended by R.2003 d.240, effective June 16, 2003.
See: 34 N.J.R. 3045(a), 35 N.J.R. 2637(c).
In (c)2, added "N.J.A.C. 5:23-3.16(c) Automatic rain sensor device".
Amended by R.2003 d.418, effective November 3, 2003.
See: 35 N.J.R. 21(a), 35 N.J.R. 5064(a).
Rewrote the section.
Amended by R.2004 d.131, effective April 5, 2004.
See: 35 N.J.R. 5336(a), 36 N.J.R. 1755(a). |
- |
pdf_text |
| full-text (cont. 2) |
where the
area exceeds 1,500 square feet (139.4 m2) and" shall be deleted. Additionally, in It
in the first sentence, "exterior stairway complying with Section 1011 or an outside
complying with Section 1012" shall be deleted and "exterior exit stairway or ramp
complying with Section 1027" shall be inserted.
ix. At Section 903.3.1.1.1, Exempt locations, "fire code official" shall be deleted a
protection subcode official" shall be inserted in number 1. |
- |
pdf_text |
| full-text (cont. 2) |
hydraulically designe
sprinkler systems by affixing a permanently marked weatherproof metal or rigid plastic si
alarm valve. The nameplate shall contain information relative to the design parameters of
system as indicated on Form No. F380. The plate shall be secured at the alarm valve with
corrosion resistant wire, chain, or other approved means. |
- |
pdf_text |
| full-text (cont. 2) |
and the reg
to enforce the provisions of the building subcode within the jurisdiction of the enf
agency."
ix. The definition of "change of occupancy" shall be deleted.
x. The definition of "clinic, outpatient" shall be amended as follows: the phrase "
not rendered incapable of self-preservation by the services provided" shall be delet
"where evacuation is slow" shall be inserted.
xi. The definition of "deferred submittal" shall be deleted. |
- |
pdf_text |
| full-text (cont. 2) |
and entrance."
xxii. The definition of nursing home shall be amended as follows: the phrase "inc
self-preservation" shall be deleted, and "of impractical evacuation" shall be inserte
xxiii. The definition of "owner" shall be deleted and the following shall be inserte
"OWNER. The owner or owners in fee of the property of a lesser estate therein, a
mortgagee or vendee in possession, an assignee of rents, receiver, executor, trustee |
- |
pdf_text |
| full-text (cont. 2) |
"except as otherwise
or approved by the fire code official" shall be deleted.
lxix. Section 912.6, Backflow protection, "International Plumbing Code" shall
deleted and "the plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| full-text (cont. 2) |
s follows: "Res
Group R-5 occupancies shall include all detached one- and two-family dwellings n
than three stories in height with a separate means of egress and multiple single-fa
townhouses not more than three stories in height with a separate means of egress d
and constructed in accordance with the International Residential Code. This Group
also include:
Care facilities that provide accommodations for five or fewer persons receiving c |
- |
pdf_text |
| full-text (cont. 2) |
ll be deleted. The sentence shall start with "Every." In add
Exceptions 1 and 2 shall be deleted in their entirety.
xxxv. Sections R319.5, Replacement windows for emergency escape and rescue o
R319.5.1, Window opening control device and fall protection device height, R319.
Dwelling additions, R319.7, Alterations or repairs of existing basements, and R31
Existing emergency escape rescue openings, shall be deleted. |
- |
pdf_text |
| full-text (cont. 2) |
he top of the footing. The top of the drain shall be covered with an approved fi
membrane material. Where a drain tile or perforated pipe is used, the invert of
or tile shall not be higher than the floor elevation. The top of joints or the top o
perforations shall be protected with an approved filter membrane material. The
tile shall be placed on not less than 2 inches (51 mm) of gravel or crushed ston
complying with Section R406.4.1 and shall be covered with not less than 6 inc
mm) of the same material. |
- |
pdf_text |
| full-text (cont. 2) |
. In Section 1015.8, Window openings, "36 inches (95mm)" shall be deleted a
inches (610 mm)" shall be inserted.
xxvii. Section 1020.2.1, Hoistway opening protection is deleted.
xxviii. In Table 1020.2, Corridor Fire Resistance Rating, under the heading "Occu
"U," shall be deleted from the third row.
xxix. In Section 1030.1.1, Bleachers, after "ICC 300", insert "Chapters 2, 3 and 4. |
- |
pdf_text |
| full-text (cont. 2) |
leted "
following "413.5.2", inserted "3305.0" following "414.5", and deleted "408.3.1", "3305.0" and "4 |
- |
pdf_text |
| full-text (cont. 2) |
nd (b)4xi as (b)4xi and (b)4xii; added (b)8
recodified former (b)8vi through (b)8xlv as (b)8vii through (b)8xlvi; deleted former (b)10iii6; an
recodified former (b)10iii7 through (b)10iii22 as (b)10iii6 through (b)10iii21. |
- |
pdf_text |
| full-text (cont. 2) |
This Group
also include:
Care facilities that provide accommodations for five or fewer persons receiving c
Single residential occupancies, accessory to a dwelling unit, having no more
roomers or lodgers. (Single occupancies, accessory to a dwelling unit, having
five roomers or lodgers shall be classified as Group R-2 or I-1, as appropriate.);
Group Homes with 5 or fewer occupants in accordance with Section 308.2.4;
Rooming houses with five or fewer residents; |
- |
pdf_text |
| full-text (cont. 2) |
Condition 1 sh
deleted and Conditions 2 through 6 shall be renumbered 1 through 5 with no chang
text.
xi. At Section 3006.3, Elevator hoistway door protection, item 4 shall be deleted i
entirety.
xii. In Section 3008.6.6, Two-way communication system, in the first sentence, "
alternate location approved by the fire department and" shall be deleted. |
- |
pdf_text |
| full-text (cont. 2) |
permeability of the soil, rate at which water enters the drainage system, rated c
of pumps, head against which pumps are to operate and the rated capacity of th
disposal area of the system.
R406.2 Dampproofing. Where hydrostatic pressure will not occur, floors and
other than wood foundation systems shall be dampproofed in accordance with
section. Wood foundation systems shall be constructed in accordance with AW |
- |
pdf_text |
| full-text (cont. 2) |
of portland cement mortar. The parging shall be coved
footing.
Exception: Parging of unit masonry walls is not required where a material is
for direct application to the masonry.
R406.3 Waterproofing. Where the ground-water investigation indicates that a
hydrostatic pressure condition exists, and the design does not include a ground |
- |
pdf_text |
| full-text (cont. 2) |
"; and rewrote (d)1.
Amended by R.2016 d.031, effective April 4, 2016.
See: 47 N.J.R. 2323(a), 48 N.J.R. 581(a).
Rewrote the section. |
- |
pdf_text |
| full-text (cont. 2) |
ypes IIIB or VB," at the beginning of the sentence. Additionally, ins
accommodate 100 or fewer persons," following "level of exit discharge."
viii. In Section 903.2.7.2, Group M upholstered furniture or mattresses, the text sh
deleted, and the following language from Section 903.2.7, item 4, of the IBC/2018
inserted: An automatic sprinkler system shall be provided throughout buildings co
a Group M Occupancy utilized for the display and sale of upholstered furniture or
mattresses exceeding 5,000 square feet |
- |
pdf_text |
| full-text (cont. 2) |
the fifth undesignated paragraph. |
- |
pdf_text |
| full-text (cont. 2) |
ydraulically designe
sprinkler systems by affixing a permanently marked weatherproof metal or rigid plastic si
alarm valve. The nameplate shall contain information relative to the design parameters of
system as indicated on Form No. F380. The plate shall be secured at the alarm valve with
corrosion resistant wire, chain, or other approved means. |
- |
pdf_text |
| full-text (cont. 2) |
d "
be inserted. Under construction Type IIB for Group R-1 S, "5" shall be deleted
shall be inserted. In addition, under construction Type IIIB for Group R-1 S, "
be deleted and "4" shall be inserted. Finally, under construction Type IVB for
"12" shall be deleted and "10" shall be inserted.
(20) Under construction Type IB for Group R-2 S, "12" shall be deleted and "
be inserted. Under construction Type IIB for Group R-2 S, "5" shall be deleted |
- |
pdf_text |
| full-text (cont. 2) |
acturer's installation instructions.
R406.3.2.1 Surface preparation of walls. Prior to the application of waterproof
materials on concrete or masonry walls, the walls shall be prepared in accorda
Section R406.2.2.1. |
- |
pdf_text |
| full-text (cont. 2) |
red in a specific instance relating to a specific permit or structure, except that any su
formal technical opinion may be considered in the context of an appeal from any such ruli
(c) The Construction Code Element may issue bulletins to provide advice to code enforci
agencies, builders, and designers. Bulletins may be issued when the Element finds that an
that is in need of clarification is adequately dealt with by existing rules and that rulemakin
therefore not appropriate or necessary. Consultation with the Code Advisory Board shall b
required prior to the issuance of any bulletin. |
- |
pdf_text |
| full-text (cont. 2) |
2002 d.6, effective January 7, 2002.
See: 33 N.J.R. 2570(a), 33 N.J.R. 3883(a), 34 N.J.R. 268(a). |
- |
pdf_text |
| full-text (cont. 2) |
er override" shall be deleted and "firefig
emergency operation" shall be inserted.
xi. Section 2.26.2, Where Elevator Pit Drainage is Provided, shall be amended as
(1) In subsection b, "Where the drainage discharge is outdoors," shall be delet
"the" shall be capitalized. |
- |
pdf_text |
| full-text (cont. 2) |
shal
inserted.
xxv. In Section 1015.8, Window openings, "36 inches (95mm)" shall be deleted a
inches (610 mm)" shall be inserted.
xxvi. In Table 1020.2, Corridor Fire Resistance Rating, under the heading "Occup
"U," shall be deleted from the third row.
xxvii. In Section 1030.1.1, Bleachers, after "ICC 300", insert "Chapters 2, 3 and 4 |
- |
pdf_text |
| full-text (cont. 2) |
begins with NS shall be deleted.
(11) Under construction Type IA for Group H-2 S, "UL" shall be deleted and
be inserted. In addition, for construction type VB for Group H-2 S, "1" shall be
and "NP" shall be inserted.
(12) Under construction Type IA for Group H-3 S, "UL" shall be deleted and
be inserted. In addition, under construction Type IIIA for Group H-3 S, "4" sha
deleted and "3" shall be inserted. |
- |
pdf_text |
| full-text (cont. 2) |
iii. Section 1108.7.3, Elevator service to the lowest story with units, shall be del
its entirety.
xliv. Section 1108.7.4, Site impracticality, "Type B units" in the second line of th
and in Items 1, 2, 3, and 4 shall be deleted and "Type A units" inserted in its place. |
- |
pdf_text |
| full-text (cont. 2) |
led on, above, or below the surface of a parcel of lan
provided the word "structure" shall be construed when used herein as though follo
the phrase "or part or parts thereof and all equipment therein" unless the context cl
requires a different meaning.
xxxviii. The definitions of the terms "substantial improvement" and "substantial d
shall be deleted.
xxxix. The definition of "Type B Unit" shall be deleted. |
- |
pdf_text |
| full-text (cont. 2) |
dered in a specific instance relating to a specific permit or structure, except that any su
formal technical opinion may be considered in the context of an appeal from any such ruli
(c) The Construction Code Element may issue bulletins to provide advice to code enforci
agencies, builders, and designers. Bulletins may be issued when the Element finds that an
that is in need of clarification is adequately dealt with by existing rules and that rulemakin
therefore not appropriate or necessary. Consultation with the Code Advisory Board shall b
required prior to the issuance of any bulletin. |
- |
pdf_text |
| full-text (cont. 2) |
ection R323, Storm Shelters, shall be deleted.
xli. Section R326, Habitable attics, shall be deleted.
xlii. In Section R327.1, General, "and enclosures" shall be inserted between "spas
"shall."
xliii. A new Section R327.2, Amendments to the International Swimming Pool an
Code, shall be inserted as follows: |
- |
pdf_text |
| full-text (cont. 2) |
truction Type IB for Group S-2 NS, "11" shall be deleted and
be inserted and for Group S-2 S, "12" shall be deleted and "8" shall be inserted
addition, under construction Type VA for Group S-2 NS, "4" shall be deleted a
shall be inserted and for Group S-2 S, "5" shall be deleted and "4" shall be inse
(25) Group U shall be deleted.
iv. Table 506.2, ALLOWABLE AREA FACTOR IN SQUARE FEET, shall be a
as follows: |
- |
pdf_text |
| full-text (cont. 2) |
ncluding but not limited to, me
other food services, and assistance in dressing, bathing or attending to other person
needs."
xxxii. The definition of "single residential occupancy" shall be inserted as follows
"SINGLE RESIDENTIAL OCCUPANCY: A building arranged or used for i
non-transient residency by persons living independently of one another, rega |
- |
pdf_text |
| full-text (cont. 2) |
inserted. Finally, under construction Type VA for Group A-2 NS, "2"
deleted and "1" shall be inserted and for Group A-2 S, "3" shall be deleted and
be inserted.
(4) Under construction Type IB for Group A-3 NS, "11" shall be deleted and "
be inserted and for Group A-3 S, "12" shall be deleted and "6" shall be inserted
construction Type IVB for A-3 S, "12" shall be deleted and "6" shall be inserte |
- |
pdf_text |
| full-text (cont. 2) |
" shall be inserted
(9) Under construction Type IB for Group F-2 NS, "11" shall be deleted and "
be inserted and for Group F-2 S, "12" shall be deleted and "8" shall be inserted
(10) Under Occupancy Classifications H-1, H-2, H-3, H-4, and H-5, the row t
begins with NS shall be deleted.
(11) Under construction Type IA for Group H-2 S, "UL" shall be deleted and
be inserted. In addition, for construction type VB for Group H-2 S, "1" shall be
and "NP" shall be inserted. |
- |
pdf_text |
| full-text (cont. 2) |
leted and "6" shall be inserted
construction Type IVB for S-1 S, "7" shall be deleted and "6" shall be inserted.
addition, under construction Type VA for Group S-1 NS, "3" shall be deleted a
shall be inserted and for Group S-1 S, "4" shall be deleted and "3" shall be inse
(24) Under construction Type IB for Group S-2 NS, "11" shall be deleted and
be inserted and for Group S-2 S, "12" shall be deleted and "8" shall be inserted
addition, under construction Type VA for Group S-2 NS, "4" shall be deleted a
shall be inserted and for Group S-2 S, "5" shall be deleted and "4" shall be inse |
- |
pdf_text |
| full-text (cont. 2) |
hall be deleted and "fire pr
subcode official" shall be inserted.
lvi. Section 909.12.1, Verification, in the exception, "building official" shall be de
and "fire protection subcode official" shall be inserted. |
- |
pdf_text |
| full-text (cont. 2) |
finition of "lodging house" shall be deleted.
xxiv. In the definition of "merchandise pad," "as indicated in Section 105.2" shall
deleted.
xxv. A definition of "nightclub" shall be inserted as follows: |
- |
pdf_text |
| full-text (cont. 2) |
hall be inserted.
(18) Under Occupancy Classifications R-1, R-2, R-3, and R-4 the row that beg
NS shall be deleted.
(19) Under construction Type IB for Group R-1 S, "12" shall be deleted and "
be inserted. Under construction Type IIB for Group R-1 S, "5" shall be deleted
shall be inserted. In addition, under construction Type IIIB for Group R-1 S, " |
- |
pdf_text |
| full-text (cont. 2) |
in l
such as repair garages, where the presence of carbon monoxide may be expe
function of the normal use of the space. Additionally, carbon monoxide
equipment shall not be required in locations where battery charging for
equipment takes place. In such locations, carbon monoxide detection equipm
be provided just outside such spaces at the points where these spaces connect
occupiable space(s)."
xc. Section 915.6, Maintenance, shall be deleted in its entirety. |
- |
pdf_text |
| full-text (cont. 2) |
red Design Professional in Responsible Charge" sh
deleted.
xxxi. The definition of the "Relocatable Building" shall be deleted.
xxxii. The definition of "repair" shall be deleted.
xxxiii. The definition of the "residential health care facility" shall be inserted as fo
"RESIDENTIAL HEALTH CARE FACLILITY. A facility not located with, and
by, a licensed health care facility that provides food, shelter, supervised health |
- |
pdf_text |
| full-text (cont. 2) |
nformational Notes" for "Fine Print Notes (FPNs)" and "12-1" for "09-1"; in (b)2i, d |
- |
pdf_text |
| full-text (cont. 2) |
See: 41 N.J.R. 3140(a), 42 N.J.R. 2043(a).
Rewrote (a) and (c). |
- |
pdf_text |
| full-text (cont. 2) |
shall be inserted.
xi. In Section G2427.5.5, Inspection of chimneys, "examined to ascertain that it is
and free of obstructions" shall be deleted and "inspected in accordance with the ch
verification program as provided for in N.J.A.C. 5:23-2.20(d)" shall be inserted.
xii. In Section G2448.1.1, Installation requirements, "this code" shall be deleted a
plumbing subcode (N.J.A.C. 5:23-3.15)" shall be inserted. |
- |
pdf_text |
| full-text (cont. 2) |
s:
(1) Subsection b. shall be deleted.
(2) In subsection d, "Phase II firefighter override" shall be deleted and "firefig
emergency operation" shall be inserted.
xi. Section 2.26.2, Where Elevator Pit Drainage is Provided, shall be amended as
(1) In subsection b, "Where the drainage discharge is outdoors," shall be delet
"the" shall be capitalized. |
- |
pdf_text |
| full-text (cont. 2) |
" shall be de
Additionally, in the list of occupancies, Congregate living facilities ( non-transient
or fewer occupants, shall be deleted and Boarding houses (non-transient) shall be a
by deleting "(non-transient)," and by inserting "with 5 or fewer occupants". The te |
- |
pdf_text |
| full-text (cont. 2) |
3" shall be inserted,
respectively. In addition, under construction Type IV HT for Group A-2 NS, "
be deleted and "2" shall be inserted and for Group A-2 S, "4" shall be deleted a
shall be inserted. Finally, under construction Type VA for Group A-2 NS, "2"
deleted and "1" shall be inserted and for Group A-2 S, "3" shall be deleted and
be inserted. |
- |
pdf_text |
| full-text (cont. 2) |
Add new Section 907.2.1.1A between Sections 907.2.1.1 and 907.2.1.2
follows:
"907.2.1.1A Group A-2 Nightclubs. An automatic fire detection system sh
installed throughout all Group A-2 nightclubs with an occupant load of 100
more. If the alarm is activated by smoke detectors, it shall be activated by e
two cross-zoned smoke detectors within a single protected area or a single |
- |
pdf_text |
| full-text (cont. 2) |
definition of "dwelling unit," "living as a single housekeeping unit" shall
inserted after "persons."
xi. The definition of "existing building" shall be deleted.
xii. The definition of "existing structure" shall be deleted.
xiii. A definition of "fire code official" shall be inserted as follows: |
- |
pdf_text |
| full-text (cont. 2) |
y NFPA 780, fire"; and added (d)14.
Amended by R.2021 d.015, effective February 16, 2021.
See: 52 N.J.R. 561(a), 53 N.J.R. 245(a). |
- |
pdf_text |
| full-text (cont. 2) |
it shall be provided on that fl
the seventh line, "Type B dwelling unit" shall be deleted and "Type A unit" inserte
place. Additionally, in the eighth line, following the word "toilet," "and bathing" s
inserted. |
- |
pdf_text |
| full-text (cont. 2) |
of "Substantial Damage" shall be deleted.
xxv. The definition of "Substantial Improvement" shall be deleted. |
- |
pdf_text |
| full-text (cont. 2) |
aph of (a)1ii, substituted "2008" for
Amended by R.2015 d.139, effective September 21, 2015. |
- |
pdf_text |
| full-text (cont. 2) |
s."
xi. The definition of "Existing Installations" shall be deleted.
xii. The definition of "Guestroom" shall be deleted.
xiii. The definition of "Historic Building" shall be deleted.
xiv. The definition of "Jurisdiction" shall be deleted.
xv. The definition of "Lodging House" shall be deleted. |
- |
pdf_text |
| full-text (cont. 2) |
e
xxv. In Table 1705.7, Required special inspections and test of driven deep founda
elements, at Item #7, "registered design professional" shall be deleted and "person
inserted.
xxvi. In Section 1705.9, Helical pile foundations, in the second sentence, "registe
design professional" shall be deleted and "person" shall be inserted. |
- |
pdf_text |
| section 1103.12.5.4 |
section 1103.12.5.4, entitled "Cooktop"; section 1103.12.5.5, entitled "Oven"; |
- |
pdf_text |
| section 1103.12.5.6 |
section 1103.12.5.6, entitled "Refrigerator/Freezer." |
- |
pdf_text |